Ge e Cell MK 3 L

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Lenntech

[email protected] Tel. +31-152-610-900

E-Cell MK-3 Stack


www.lenntech.com Fax. +31-152-616-289

Industrial Electrodeionization (EDI) Stacks


E-Cell MK-3 is designed to: Typical Performance
• Provide Ultrapure Water for industrial applica-
Product Quality
tions including Power, Semiconductor, and
General Industry. Resistivity > 16 MOhm-cm
• Produce Mixed Bed quality water on a con-
tinuous basis. Sodium < 3 ppb
• Require no caustic or acid for regeneration of Silica (SiO2) Removal Up to 99% or < 5 ppb
mixed bed resin within the stack.
• Be leak free, guaranteed. Boron Removal > 95%

• Eliminate brine injection and concentrate recircu- Operating Parameters


lation, simplifying system design.
Recovery Up to 95%
Description and Use Counter current vs.
Concentrate Flow Product Flow
MK-3 E-Cell stacks are electrodeionization (EDI)
stacks which use electrical current to deionize and Voltage 0 – 300 VDC
polish reverse osmosis (RO) permeate water. The
Amperage 0 – 5.2 ADC
product water for the MK-3 is at an Ultrapure level
required in today’s most demanding applications. Inlet Pressure 4.8 – 6.9 bar 70 – 100 psi

Typical Applications Pressure Drop at Nominal Flow 1.4 – 2.4 bar 20 – 35 psi

• Semiconductor
• Microelectronics Maximum Feed Water Specifications
• Power Generation (NOx, Boiler Feed)
• General Industry Feed Water - Total Exchange- <25 mg/l <25 ppm
able Anions (TEA as CaCO3)
Quality Assurance Feed Water – Conductivity, < 43 µS/cm < 43 µS/cm
NaHCO3 equivalent
• CE, UL & CSA marked
• Manufactured in a ISO 9001:2000 facility Temperature 4.4 – 38˚C 40 – 100˚F
Total Hardness (as CaCO3) < 1.0 mg/l < 1.0 ppm
MK-3 Stack Specifications Silica (SiO2) < 1.0 mg/l < 1.0 ppm
Nominal Flow 3.4m3/hr 15.0 gpm Total Organic Carbon (TOC as C) < 0.5 mg/l < 0.5 ppm
Flow Rate Range 1.7 – 4.5 m3/hr 7.5 – 20.0 gpm
Total Chlorine < 0.05 mg/l < 0.05 ppm
Shipping Weight 92 kg 202 lbs
Dimensions 30 cm x 61 cm x 48 cm 12” x 24” x 19” Actual performance may vary depending on site conditions.
(width x height x depth)
Reference E-Calc projection software to verify actual performance.
Patents pending

Lenntech
[email protected] Tel. +31-152-610-900
www.lenntech.com Fax. +31-152-616-289

FS1622EN.doc Jun-08