Control Units

>> Overview - Actuators page 8


- OKTRON series page 16
- OKTRON-R series page 36
- QUARTRON series page 54
- RONTRON-R-JUWEL series page 72
- RONTRON-Q-JUWEL series page 106
- SHORTRON series page 124
- SHORTRON series for base-plate mounting page 156
- SHORTRON M12 page 174
- RX-JUWEL series page 184
- RONDEX series page 198
- RONDEX-M series page 214
- DUX-Basic series page 230
- QUARTEX-R series page 252
- RVA stainless steel series page 268
- KOMBITAST-R-JUWEL series page 278
- OKTRON-JUWEL series page 310
- QUARTRON-JUWEL series page 328
- QUARTEX-R-JUWEL series page 348
- Vandalism-proof actuators page 362
- Emergency Stop Buttons page 366

>> Overview - Contact Blocks page 408


- electric contact blocks with PCB-mount terminals page 468, 482,
496, 502
- electric contact blocks with Faston terminals page 410, 420, 428,
442, 450, 474,
490, 496
- electric contact blocks with screw connections page 436, 460,
508, 514
- electric contact blocks with spring clamp connect. page 522, 528
- contact blocks for AS-Interface page 534
- battery-free wireless modules page 546
Series Overview - Actuators made in germany

Panel cut-out: Ø 16.2 mm


About Us

3 3 6
Æ Actuators
Control Units

OKTRON OKTRON-R QUARTRON


Front dimensions: page Front dimensions: page Front dimensions: page
25 x 25 mm 16 Ø 25 mm 36 25 x 25 mm 54
Panel Mount Jacks

Panel cut-out: Ø 22.3 mm


3 1,2 3 1,2
Bus Technology

RONTRON-R-JUWEL RONTRON-Q-JUWEL SHORTRON


Front dimensions: page Front dimensions: page Front dimensions: page
Ø 28 mm 72 28 x 28 mm 106 Ø 28 mm 124
Enclosures

1,2 1,2 6
Terminal Blocks

SHORTRON for base-plate mounting SHORTRON M12 RX-JUWEL


Front dimensions: page Front dimensions: page Front dimensions: page
Ø 28 mm 154 Ø 28 mm 174 Ø 28 mm 184
6 6 6
Pedal Switches
Limit Switches

RONDEX RONDEX-M DUX-Basic


Front dimensions: page Front dimensions: page Front dimensions: page
Ø 28 mm 198 Ø 28 mm 214 Ø 30 mm 230
6 6
Type Index

QUARTEX-R RVA stainless steel


Front dimensions: page Front dimensions: page
30 x 30 mm 252 Ø 28 mm 268
8 Georg Schlegel GmbH & Co. KG - 88525 Dürmentingen - § +49 (0) 73 71 / 502-0 - Fax: +49 (0) 73 71 / 502 49 - [email protected] - www.schlegel.biz
Panel cut-out: Ø 30.5 mm Panel cut-out: 25x25 mm Panel cut-out: 27x27 mm

About Us
6 3 6

Æ Actuators
Control Units
KOMBITAST-R-JUWEL OKTRON-JUWEL QUARTRON-JUWEL
Front dimensions: page Front dimensions: page Front dimensions: page
Ø 36 mm 278 25 x 25 mm 310 27 x 27 mm 328

Panel Mount Jacks


Panel cut-out: 30x30 mm
6

Bus Technology
QUARTEX-R-JUWEL
Front dimensions: page
30 x 30 mm 348

Enclosures
Vandalism-proof Actuators Emergency Stops Nameplates

2,3

page page page Terminal Blocks


Pedal Switches
362 366 404

Battery-free Radio
Contact Blocks Bus technology
Contact Block
Limit Switches

page
Type Index

534
page page page
408 546 572

Georg Schlegel GmbH & Co. KG - 88525 Dürmentingen - § +49 (0) 73 71 / 502-0 - Fax: +49 (0) 73 71 / 502 49 - [email protected] - www.schlegel.biz 9
made in germany

>> Control Units


About Us

Use & Application Fields Illumination


Schlegel control units include a variety of complete pushbutton and For the illumination of pushbuttons, selector or key switches and
switch series for front-panel and base-plate mounting. The actuators pilot lights either incandescent lamps, neon lamps or LED’s can be
are designed for exclusive applications as well as for use in harsh used. The contact units are optionally available with BA9s, T5,5K or
environments. They are housed in attractive, square, rectangular or W2x4,6d sockets or integrated LEDs, depending on the particular
round insulating bodies, allowing side-by-side assembly and thus type series.
full keyboard arrangements.
Æ Actuators
Control Units

Due to the flexible contact configurations and ease of assembly, the Marking Options
units can be used in every field of application. With the importance of an efficient component marking in mind,
the Schlegel control units have been designed to accept a clearly
Mounting of Actuators visible marking, easy to produce and comprising a variety
First, the required mounting holes have to be drilled, punched or of symbols and inscriptions. Hence, a multitude of standard
lasered (refer to the relative drilling pattern on the starting page of nameplates are available, but also customer-specific imprints are
each series). For round cut-outs, keep in mind to provide a recess possible.
Panel Mount Jacks

for the locating lug. The nameplates are inserted under the lenses and are thus
The actuators are then inserted into the cut-outs and fixed with a protected from wearing and soiling. Still today this is the best
mounting nut on the rear. system which was originally a development of Georg Schlegel.
Because they are almost completely recessed in the panel, the Other marking options offer the external markings using special
square Juwel actuator housings require a spacer to be put on from nameplate holders. These nameplates can also be printed with
behind before securing them with the mounting nut. standard symbols or according to users’ requirements.
Lenses and nameplates have to be ordered separately
unless otherwise stated. This provides high flexibility Front Bezel Colours (refer to the relative series)
to the combination of lens colours and inscriptions Other front bezel colours can be supplied on request.
Bus Technology

once the control units are mounted in the panel (see


illustration under “Mounting and Service Instructions”).

Mounting of Contact Blocks We reserve the right to make modifications in the interest of
All Schlegel contact blocks have rounded corners and edges and technical progress. All information given herein serves only for
thus allow a comfortable use without risk of injury. product description and is not legally binding.
For the 22 mm series with bayonet applies: With the M...type Misprints and errors do not justify any claims.
series, first insert the contact modules into a module holder, then This publication, even part of it, may not be reproduced without our
snap the module holder onto the actuator neck by a rotary motion prior permission.
Enclosures

(bayonet coupling). For side-by-side arrangements with the D... Illustrations can deviate.
type series, snap the module holder onto the actuator neck first by Internationally protected design.
a rotary motion, then insert the contact modules into the module
holder. The contact blocks ETR.. (one-piece) do not need a module
Please refer to www.schlegel.biz/web/de/manuals.php
holder, so snap them directly onto the actuator. As to the actuators
for detailed instructions for use and assembly.
with 16mm bayonet, simply snap the contact blocks of the type
series A, B, C and P onto the actuator neck (no module holder
Terminal Blocks

necessary). A slight twist enables to snap them off again.


The contact units of the type series CTP and CZ (suitable for PCB’s)
are first soldered onto the PCB, then put onto the actuator of the 16
mm series and fixed by a small locking bolt. This bolt can be moved
with a screwdriver through a hole in the PCB.

Assembly Instructions for Base-plate Mounted Version


- snap the relative contact block onto the actuator neck
Pedal Switches

- Spacer sleeves ensure the correct distance between PCB and


mounting plate.
- Screws must be secured against loosening.

Note for base-plate mounted type “FRVKZ” (with plunger


extension): ATTENTION: must not be used for the illuminated
version !
Note for base-plate mounted type “FRVKZL” (with plunger
extension): ATTENTION. use only for the illuminated version !
Limit Switches
Type Index

10 Georg Schlegel GmbH & Co. KG - 88525 Dürmentingen - § +49 (0) 73 71 / 502-0 - Fax: +49 (0) 73 71 / 502 49 - [email protected] - www.schlegel.biz
made in germany

Degree of Protection (acc. to IEC/EN 60529) Technical Characteristics


The SCHLEGEL actuators generally comply with IP65 (this refers to the As to the technical characteristics, approvals and operating and

About Us
component in front of the switchboard). Special versions, as e.g. for ambient conditions of the contact blocks, please refer to the
the food processing sector, are classified up to IP69K. catalogue information given on the starting pages of the relevant
For extremely severe conditions, e.g. coarse dirt, chippings, flour, type series.
etc., there are membrane pushbuttons available or actuators with The stroke / operating travel is shown in pictograms separately
transparent silicone or PVC caps. for each actuator and in switching diagrams for the relevant
contact blocks. This information is included as well in the technical
Materials specifications.

Æ Actuators
Control Units
Only top-quality materials such as polyamide 6.6 / polyamide
12 (partially reinforced) and other proven engineering plastics
are utilised. Tin-plated brass is mostly used for the terminals of the The positive opening function of the NC contacts, which is necessary
contact blocks. The contacts are of a silver-nickel alloy but can also for emergency-stop applications is identified by a symbol (circle with
be gold-plated on request (gold-plating 5 μm). A special surface horizontal arrow) next to the relative switching diagram.
makes them self-cleaning.
All products are RoHS compliant.

Panel Mount Jacks


Definition of the IP Codes

Standards & Code Numerals or


Protection of equipments Protection of persons
Digits Letters

Bus Technology
Protection against solid foreign objects (incl.
EN 60529 Protection against hazardous parts
dust)
0 non-protected non-protected
1 ≥ Ø 50 mm with the back of a hand
2 ≥ Ø 12.5 mm with a finger
First digit 3 ≥ Ø 2.5 mm with a tool
4 ≥ Ø 1.0 mm with a wire

Enclosures
5 dust-protected with a wire
6 dust-tight with a wire

Protection against ingress of water with harmful


effects
0 non-protected
1 vertically falling water drops

Terminal Blocks
2 water drops (tilted up to 15°)
3 spraying water
4 splashing water
Second digit
5 water jets
6 powerful water jets
7 temporary immersion in water
8 continuous immersion in water
9 high pressure and high temperature water jets Pedal Switches

Protection against solid foreign objects (incl.


ISO 20653:2013
dust)
9K high pressure and high temperature water jets
Second digit
Limit Switches
Type Index

Georg Schlegel GmbH & Co. KG - 88525 Dürmentingen - § +49 (0) 73 71 / 502-0 - Fax: +49 (0) 73 71 / 502 49 - [email protected] - www.schlegel.biz 11
made in germany

Approvals
About Us

Symbol Name / Organisation Explication

CE Kennzeichen, With the CE mark, the manutacturer confirms that the product meets the product-
Communautès Europèennes specific requirements of the applicable EC Directives.
VDE
The VDE mark indicates conformity with the VDE Standards or European or
Æ Actuators
Control Units

Verband der Elektrotechnik


internationally harmonised standards and confirms conformity with the safety
Elektronik Informationstechnik
requirements of the applicable directives.
e.V.
European approval mark (applies to switches for appliances acc. to EN 61058).
ENEC
Replaces the national European Directives of the participating countries. The figure
European Norms Electrical
after the ENEC marking refers to the relative national certification authority, e.g.
Certification
05=KEMA, 10=VDE.
Panel Mount Jacks

KEMA
Keuring van Elektrotechnische Certification mark of the Dutch approval authority
Materialen te Arnhem

UL Listed mark,
Underwriters Laboratories representative samples of the product have been tested by UL and are complying with
the US safety requirements.
Bus Technology

UL Listed mark,
Underwriters Laboratories representative samples of the product have been tested by UL and are complying with
the US and Canadian safety requirements.

UL Recognized mark,
Underwriters Laboratories
UL marking for approved components that are part of a larger product or system
UL Recognized mark,
Enclosures

Underwriters Laboratories representative samples of the product have been tested by UL and are complying with
the US and Canadian safety requirements.
Approval mark of the Canadian certification authority,
Canadian Standards
products bearing this mark have been certified by CSA and are complying with the
Association
applicable Canadian Standards.

Approval mark of the Canadian certification authority,


Canadian Standards
products bearing this mark have been certified by CSA and are complying with the
Terminal Blocks

Association
applicable Canadian and US Standards.

Danish approval mark which is registered and provided by UL International Demko


Demko A/S. The D mark demonstrates that the certified product complies with the applicable
requirements.

Nemko Certification mark of the Norwegian approval authority


Pedal Switches

Semko Certification mark of the Swedish approval authority

Fimko Certification mark of the Finnish approval authority

Certification mark of the Norwegian approval authority


Limit Switches

Det Norske Veritas


Products bearing this mark comply with the ship classification requirements

Certification mark of the German approval authority


Germanischer Lloyd
Products bearing this mark comply with the ship classification requirements

UkrSEPRO Certification mark of the Ukrainian approval authority


Type Index

Gost-R Certification mark of the Russian approval authority

12 Georg Schlegel GmbH & Co. KG - 88525 Dürmentingen - § +49 (0) 73 71 / 502-0 - Fax: +49 (0) 73 71 / 502 49 - [email protected] - www.schlegel.biz
made in germany

Approvals

About Us
Symbol Name / Organisation Explication

China Compulsory Certificate Certification mark of the Chinese approval authority CQC

German approval authority

Æ Actuators
Control Units
TÜV Approval authority for safety-related components such as emergency-off /
emergency-stop components

AS-International Association Mark for certified AS-Interface components

Lloyd’s Register of Shipping,


Lloyd’s Register

Panel Mount Jacks


UK approval authority for ship certification

Bus Technology
Enclosures
Terminal Blocks
Pedal Switches
Limit Switches
Type Index

Georg Schlegel GmbH & Co. KG - 88525 Dürmentingen - § +49 (0) 73 71 / 502-0 - Fax: +49 (0) 73 71 / 502 49 - [email protected] - www.schlegel.biz 13
made in germany

Mode of Operation of 3-position Selector and Key


Switches
About Us

One-piece plunger:
The one-piece plunger of the 3-position selector and key switches 1. left-hand = switching travel 0mm = NC closed, NO open
is not pushed in the left position, in the centre position it is pushed 2. centre = switching travel ~3mm = NC and NO are open
half way whereas in the right switching position it is entirely pushed 3. right-hand = switching travel 6 mm = NC open, NO closed
through.
Using a contact block with a NC contact (opens after a travel of This yields the advantage that it is not important in which „direction“
Æ Actuators
Control Units

approx. 1.5mm) and a NO contact (closes after a travel of approx. the contact elements are snapped on, the switching situation always
4mm), the switching mode changes as follows: results from the switching travel. This also means that cross coupling
of the contact elements is allowed.
Panel Mount Jacks
Bus Technology
Enclosures

13 14 11 12 13 14 11 12 13 14 11 12
Terminal Blocks
Pedal Switches

illustration of one-piece plunger


Limit Switches
Type Index

14 Georg Schlegel GmbH & Co. KG - 88525 Dürmentingen - § +49 (0) 73 71 / 502-0 - Fax: +49 (0) 73 71 / 502 49 - [email protected] - www.schlegel.biz
made in germany

Two-piece plunger:
The actuator plunger consists of 2 separate half shells. In the left The two-piece plunger is used in the selector heads and key

About Us
switching position the left plunger part actuators of the following series:
and therefore the left contact element is operated, in the right Oktron, Oktron-R, Oktron-Juwel, Rontron-R-Juwel, Rontron-RJ-
switching position it is the right contact element. In the centre Edelstahl, Rontron-Q-Juwel and RX-Juwel (RXJZSSA12E and
position none of the two contact elements is activated. Therefore, it RXJZWBL), Kombitast-R-Juwel (KRJZ...).
should be noted that a cross-coupling of the contact elements
is NOT allowed! In addition, the contact elements must be snapped
on correctly, otherwise any actuation will lead to the opposite

Æ Actuators
Control Units
function.
In order to obtain the same switching situations as mentioned
before, two NO contacts must be used:
1. left-hand = left plunger part operated = left NO contact closed,
right NO contact open
2. centre = no plunger part operated = both NO contacts open
3. right-hand = right plunger part operated = left NO contact open,

Panel Mount Jacks


right NO contact closed.

Bus Technology
Enclosures
13 14 23 24 13 14 23 24 13 14 23 24

Terminal Blocks
Pedal Switches

illustration of two-piece plunger


Limit Switches
Type Index