Sinamics G120 Smart Access

Download as pdf or txt
Download as pdf or txt
You are on page 1of 38

SINAMICS G120

Smart Access Module


Mobile. Clever. Faster.
Unrestricted © Siemens AG 2018 siemens.com/sinamics-accessories

Unrestricted © Siemens AG 2018


Agenda

• Product roadmap
1

• Customer benefit
2

• Compatibility
3

• Technical information
4

• Certificate
5

• Marketing roadmap / sales material


6

10

Unrestricted © Siemens AG 2018

Page 2
Product overview
Operator Panels for G120 series

SINAMICS G120 Smart Access SINAMICS Intelligent Operator SINAMICS Basic Operator Panel
Module Panel IOP-2 BOP-2

Product Web server-based control panel with Intelligent control panel for direct Basic control panel for direct
description wireless client connection connection to the converter connection to the converter

Main Mobile Local Local


functions Commissioning Operation Operation
Diagnostics Monitoring Monitoring
Service Commissioning Commissioning
Diagnostics Diagnostics
Service

Unrestricted © Siemens AG 2018


Page 3
SINAMICS web server strategy
The most significant milestones on the way to portfolio 2025

Characteristics Web server module for Web server module for Integrated web server in
SINAMICS V20 SINAMICS G120 SINAMICS S120 and S210
Necessary
additional NO additional HW
hardware: integr. in CUs

Web design:

• S120*) in delivery / S210


Status: • In delivery • In development ready for sales release
• Supports platform web
Core features: • Supports Wifi • Supports Wifi server concept
connections only connections only • S210 already supports full
• Optimized for use on • Optimized for use on responsive design for all
Unrestricted © Siemens AG 2018 mobile devices mobile devices client systems (PCSmartphone)
Page 4
*) Update to new design with FW version V5.2 scheduled for 2018
SINAMICS web server strategy
Product realization for SINAMICS G120

SINAMICS G120 Smart Access ✔ Development started for the G120 Smart Access Module
Module
Milestone Q.PM280 planned in Mar.2018

Order No.: 6SL3255-0AA00-5AA0

Unrestricted © Siemens AG 2018

Page 5
Agenda

• Product roadmap
1

• Customer benefit
2

• Compatibility
3

• Technical information
4

• Certificate
5

• Marketing roadmap / sales material


6

10

Unrestricted © Siemens AG 2018

Page 6
SINAMICS G120 Smart Access Module

Convenient access
• To the drive even if installed in difficult-to-access areas
• No cable necessary due to wireless one-to-one connection to mobile device or PC

Set up in less than one minute


• No apps/downloads required
• Operates with any of the common browsers and with any end device
All-in-one solution
• All functions are provided by the integrated web server
• One module support most of the G120 series
• 6 languages support/ Upgradable language packages
• IP55 protection level

Simple operation
• Due to intuitive/guided user interface
• Look & feel of an app
• Higher functionality than BOP

Information security
• Point to point connection/ No internet need
• WAP-2 encryption
• Support HTTPS communication protocol
Unrestricted © Siemens AG 2018

Page 7
SINAMICS G120 Smart Access Module
Connect your mobile/end device in less than one minute

1 2 3

SINAMICS G120

Search SINAMICS G120


Mount Smart Access onto Smart Access in your Open browser to access
SINAMICS G120 and Wi-Fi networks the page
switch on the module (default password: 12345678) (https://192.168.1.1)

Unrestricted © Siemens AG 2018


4* A step 4 for password changing is mandatory for the 1st access
Page 8
SINAMICS G120 Smart Access Module
Provides all the necessary functions in one device

Basic commissioning Parameters


Quick commissioning wizard that Check and set parameter values. Save
covers the areas of motor data, the preferred parameters in a
connection and application settings customizable list or reset the drive to
as well as common used parameters. the factory settings.

Control panel Monitoring


Control panel with basic functions. Overview over the most important
Supporting JOG mode and static set online values.
point mode.

Diagnostics
Get a quick overview over all current Backup & restore
faults and alarms, receive tips how to Quick way to save or restore the
solve the issues and acknowledge parameterization of the drive.
the errors. Furthermore the status of
all signal in-/outputs.

Unrestricted © Siemens AG 2018

Page 9
Customer benefits
with state-of-art wireless engineering technology

Function  Feature Benefits


• Access inverter by mobile • Connect to hotpoint of Smart Access and • No cable
device or PC open browser • Access drive which is difficult to touch
• WPA2 security protection • Engineering and service in hand
• Operating in browser by web • Smart Access provide all web page, data • No Apps
service hosted by Smart to users by inbuilt web server • Operation system and device independent
access • No internet connection need
• Documents for each • Integrated useful description of • No paper document needed
parameters and options parameters and settings in multi- • Less training / learning cost
language

Unrestricted © Siemens AG 2018


Page 10
Customer benefits
with user-friendly and flexible engineering technology

Function  Feature Benefits


• UI based on state-of-art HTML5 • H5 can support most modern operating • Web user interface for engineering
technology in mobile device like the native apps • Feeling of operating just like apps
• Support most popular browsers

• Full engineering function • Commissioning, trouble-shooting, • Do everything in mobiles more than BOP
support backup and tuning are now in air without button pressing

• Upgradable function and • Customer can download software from • Enjoy the latest functions in customer
language support Siemens and upgrade module in web UI language

Online/offline G120

identification
Fault / alarm
quick menu

Quick
Parameter editing /
commissioning
saving
wizard

Run motor in jog or Monitoring status of


setpoint inverter

Quick overview of Backup and restore


fault, alarm and settings to mobile
status
Smart access options

Call hotline Product identification

Unrestricted © Siemens AG 2018


Page 11
Agenda

• Product roadmap
1

• Customer benefit
2

• Compatibility
3

• Technical information
4

• Certificate
5

• Marketing roadmap / sales material


6

10

Unrestricted © Siemens AG 2018

Page 12
SINAMICS G120 Smart Access Module
for three product series: G120C, G120, G120P

SINAMICS G120C SINAMICS G120 SINAMICS G120P


PN/USS/DP
CU230P-2 CU230P-2
PN/USS/DP
CU240E-2
PN/USS/DP

SIEMENS

Unrestricted © Siemens AG 2018


Page 13
SINAMICS G120 Smart Access Module
Scope of the G120 Smart Access

• The G120 Smart Access Module is seen to address the same user groups as for the V20 Smart Access
Module. This means simple applications and simple users without interest in TIA-Integration.

• This is only be seen for the G120C, the CU230P-2 as well as the majority of the Control Units CU240E-2.
Not in focus are the CU250S-2, the safety version CU240E-2F and the decentralized drive variants like CU240D-2 and
CU250D-2. There will be NO commissioning support for Extended Safety and Encoder configurations nor EPOS
in the first delivery version in 2018.
This is >90% of the total piece count of the G120 family.

• The module HW will have up to IP55 and is intended to be used only mounted directly
on to the Control Units; no support of hand held and door mounting kit!

• Only FW version V4.7 and following will be supported.


This is analog to the decision of Startdrive NOT to support older FW versions.

Unrestricted © Siemens AG 2018

Page 14
Agenda

• Product roadmap
1

• Customer benefit
2

• Compatibility
3

• Technical information
4

• Certificate
5

• Marketing roadmap / sales material


6

10

Unrestricted © Siemens AG 2018

Page 15
SINAMICS G120 Smart Access Module

Unrestricted © Siemens AG 2018

Page 16
Technical details

MLFB: 6SL3255-0AA00-5AA0

Dimensions (H x W x D): 106.86 mm x 70 mm x 17 mm

Degree of protection: Depending upon the Control Unit IP rating to a max. of IP55/ UL Type 12 enclosure

Operating ambient temperatures: In operation 0 to 50 °C (32 to 122 °F) when directly mounted on the converter

Ambient temperature transporting and storing: -40° to +70 °C (-40 to + 158°F)

Relative humidity: < 95 % non-condensing

Conformance with standards: CE, FCC, SRRC, WPC, ANATEL

Multi-language support (six basic languages + two optional languages)


Languages:
English, Chinese, Germany, French, Italian, Spanish

Installation versions: Installation directly on the converter

Operating System: iOS, Android, Windows, Linux, Mac OS

Browser: Chrome, IE, Firefox, Safari


Unrestricted © Siemens AG 2018

Page 17
G120 Smart Access Module will provide similar UI for
SINAMICS V20

UI design

• Follow V20 Smart Access Module for


most existing features
• Improvements on the quick setup
according to the process by
STARTDRIVE, IOP, BOP
• Improve JOG, Monitoring and
diagnose according to the feedback
from the market for V20 SA and
G120 SA.
• Capability to adjust parameters and
quick setup according to the
CU+PM+FM combination.

Unrestricted © Siemens AG 2018

Page 18
SINAMICS G120 Smart Access Module
Bottom Toolbar

Support Drive Identification Settings

The support All important System settings form


information is information is the SAM can here be
displayed here an can displayed here changed
be edited

Unrestricted © Siemens AG 2018

Page 19
SINAMICS G120 Smart Access Module
Main functions

Basic commissioning Parameters


Quick commissioning wizard that Check and set parameter values. Save
covers the areas of motor data, the preferred parameters in a
connection and application settings customizable list or reset the drive to
as well as common used parameters. the factory settings.

Control panel Monitoring


Control panel with basic functions. Overview over the most important
Supporting JOG mode and static set online values.
point mode.

Diagnostics
Get a quick overview over all current Backup & restore
faults and alarms, receive tips how to Quick way to save or restore the
solve the issues and acknowledge parameterization of the drive.
the errors. Furthermore the status of
all signal in-/outputs.

Unrestricted © Siemens AG 2018

Page 20
SINAMICS G120 Smart Access Module
Quick commissioning wizard (1/3)

The inverter can be reset The second step is to set the


before commissioning or the The first step is to choose most important motor data. The motor type can be set
existing settings can be the application class Depending on the motor precisely
used type, the motor data can be
set automatically

Unrestricted © Siemens AG 2018

Page 21
SINAMICS G120 Smart Access Module
Quick commissioning wizard (2/3)

The selected I/O The I/O configuration can be The next step is to set It can be selected between
configuration is displayed changed by clicking on the important parameters for the linear char and parabolic
marked button inverter char

Unrestricted © Siemens AG 2018

Page 22
SINAMICS G120 Smart Access Module
Quick commissioning wizard (3/3)

Before the optimization, After the completion of


a motor data the commissioning the
identification must be settings can be tested
performed with the JOG

Unrestricted © Siemens AG 2018

Page 23
SINAMICS G120 Smart Access Module
JOG (1/2)

The JOG provides In order to use the JOG By default the JOG mode The JOG speed can not
functions for basic and to cover safety is enabled. Press one be changed, because it
testing rules, the control must button to spin the drive is defined during
be optained in the displayed way commissioning

Unrestricted © Siemens AG 2018

Page 24
SINAMICS G120 Smart Access Module
JOG (2/2)

To run the drive in “normal” Set a speed and start the To change the direction in Before you can leave the
setpoint mode, please drive by pressing the green which the motor rotates or control panel you have to
switch from JOG to hand button. The motor will start stop it use the buttons at the explicitly return the control
mode spinning until the stop bottom left. to the normal command
button is pressed sources

Unrestricted © Siemens AG 2018

Page 25
SINAMICS G120 Smart Access Module
Diagnostics (1/2)

Overview over all currently If needed the fault and alarm After fixing the issue An error report can be sent
active faults and alarms. history can be made visible causing the errors clicking via mail by clicking on the
More information on the by activating the toggle the Acknowledge all faults send all button. The default
issue is provided by clicking button at the top. button will clear the errors mailing program will be
on the issue. opened with the report.

Unrestricted © Siemens AG 2018

Page 26
SINAMICS G120 Smart Access Module
Diagnostics (2/2)

2 I/O 3
Overview over all Input and output
channels of the drive.
Shows online values for analog I/O
signals as well as online status
“green==1 and gray==0” for digital
I/Os.

Status bit
Shows the status of the most
important bits of the drive internal
state machine.

Unrestricted © Siemens AG 2018

Page 27
SINAMICS G120 Smart Access Module
Parameters (1/2)

On this site you get an By clicking on a parameter There is a keyword bar The filter function even
overview over all the additional information is which helps you quickly find further simplifies the work
parameters of your drive. shown and if not locked (e.g. the dedicated parameter you with the parameter list with
Values are real time values. drive state) the parameter are looking for predefined parameter
value can be changed groups.

Unrestricted © Siemens AG 2018

Page 28
SINAMICS G120 Smart Access Module
Parameters (2/2)

To keep all frequently used To customize that group After changing parameter If the drive needs to be
parameters in one group the press the “+” symbol and settings they can be saved reset there is the choice
individual “My parameters choose the parameters you to EEPROM or even be set between factory settings
group” is available. particulary interested in by as new user default values and user default settings
checking them on.

Unrestricted © Siemens AG 2018

Page 29
SINAMICS G120 Smart Access Module
Monitoring

Online Values
Displays the most important online values
from the Inverter

Faults and alarms


If there are any active faults or alarms that
have an influence on the inverter, these
are displayed in the status

Unrestricted © Siemens AG 2018

Page 30
SINAMICS G120 Smart Access Module
Backup & Restore

To Create a backup of After the backup has


your parameter settings been created, it can be A backup can be saved A backup can be saved
you have to set a name downloaded and as readable XML file and restored from an
and click on “Back up restore. SD card

Unrestricted © Siemens AG 2018

Page 31
Agenda

• Product roadmap
1

• Customer benefit
2

• Compatibility
3

• Technical information
4

• Certificate
5

• Marketing roadmap / sales material


6

10

Unrestricted © Siemens AG 2018

Page 32
SINAMICS G Smart Access Module
Certification of Wi-Fi will cover 75% sales quantity: 1st step

FCC
USA

CE
EU regions

SRRC
China
WPC
India
ANATEL
Brazil

First step: It will cover FCC, CE, SRRC, WPC, ANATEL for focused regions,
More certificates after first version release.
Unrestricted © Siemens AG 2018

Page 33
Agenda

• Product roadmap
1

• Customer benefit
2

• Compatibility
3

• Technical information
4

• Certificate
5

• Marketing roadmap / sales material


6

10

Unrestricted © Siemens AG 2018

Page 34
SINAMICS G120 Smart Access Module
Start of the 360 communication with the Hanover Fair 2018

Event Movie
Hanover Fair 2018
Short info-video

Tutorials
Press and media relations www
Siemens
Press release customer
magazine Advertising template

Online
360° SINAMICS Smart Access Module Ad

Update
www.siemens.com/sinamics- Twitter Keyvisual & pictures
accessories
“Digitalization” New product
key visual pictures
Print

Technical Integration into Flyer for promotion (4-page)


Information the SINAMICS
integrated in G- product
documents brochure Catalog D31.1.  pdf

Unrestricted © Siemens AG 2018

Page 35
SINAMICS G120 Smart Access Module
Promotion Material

Typ Document Order number

Catalogue D 31.1/D31.2 ger


Catalogue
Price list en

Internet Mall ger/en

Flyer SINAMICS G Smart Access Module ger/en

Brochure SINAMICS G ger/en

E80001-Y650-P210-V5
Selection Selection Slider G120 ger/en
E80001-Y650-P210-V5-7600
E80001-Y650-P930-V5
Selection Selection Slider G120C ger/en
E80001-Y650-P930-V5-7600
E80001-Y940-P210-V5-7600
Selection Selection Slider G120P - ger/en
E80001-Y940-P210-V5
Sinamics G120  Supplementary
Internet SINAMICS G120 accessories ger/en
system components
SINAMICS G120
Marketing Overview at MPM ger/en
Toolbox
Unrestricted © Siemens AG 2018
Page 36
SINAMICS G120 Smart Access Module
Manuals/FAQs

Document Available languages

Operating Instructions Manual ger, en, it, fr, sp, ch Available in SIOS (No. xxxx)
Smart Access Application Manual
ger, en, it, fr, sp, ch Available in SIOS (No. xxxx)
(Wizards)
Getting Started Guide ger/en/ch Has to be delivered with Module Hardware

Readme (Update Instructions)


ger, en, it, fr, sp, ch Has to be available on module and SIOS
(part of the module delivery)

SINAMICS G: Smart Access Version ger/en Available in SIOS (No. 67273266)

Product Announcement Intelligent


ger/en Available in SIOS Jan 2018
SINAMICS G: Smart Access

Sales Release SINAMICS G: Smart


ger/en Available in SIOS Feb2018
Access

Delivery Release
ger/en Available in SIOS March 2018
SINAMICS G: Smart Access

Unrestricted © Siemens AG 2018


Page 37
SINAMICS G120 Smart Access Module

Marcelo Leon Tamayo


DI MC
Km 8,5 vía a Medellín
Bogotá – Colombia
+57 314 413 0513

[email protected]

Unrestricted © Siemens AG 2018


Page 38

You might also like