Gas Scrubbing - General - EMIS
Gas Scrubbing - General - EMIS
Gas Scrubbing - General - EMIS
Removed components
Gaseous components
Dust (certain types of application)
Odour (certain types of application)
Diagram
Process description
A scrubber is a waste gas treatment installation in which a gas stream is brought into intensive contact
with a liquid, with the aim of allowing certain gaseous components to pass from the gas to the liquid.
Scrubbers can be employed as an emission-limiting technique for many gaseous emissions. Scrubbing is
also referred to as absorption.
During scrubbing there is a transfer of components from the gas phase to the liquid phase. The level of
gaseous components that can pass to the liquid phase is determined by the ability of these components to
dissolve in the liquid. Henry's Law is applicable to the solubility of gases in liquids, for low concentrations
and components with a partial pressure < 1atm:
x = mole fraction
This allows one to calculate the maximum concentration of a particular component in the washing water,
for the required end concentration. This also gives an indication about water usage under those
circumstances.
The equilibrium concentration in the vapour phase, which corresponds to a certain concentration in the
liquid phase, is determined by the temperature – the higher the temperature in the liquid phase, the higher
the equilibrium concentration in the vapour phase. Thus a reduction in temperature has a favourable e!ect
on the yield.
It is possible to increase the load by adding chemicals to the washing liquid, which help to convert
absorbed components. Thus adding chemicals that react with the absorbed gases has a positive e!ect on
the absorption yield.
Besides water (wet scrubbers), organic liquids are also used as absorption mediums. In many cases
chemicals or micro-organisms are added to the scrubbing liquid to convert or neutralise gases that are
dissolved in the liquid (conditioned scrubbers). As a result of this conversion, the concentration in the water
is reduced, which in-turn allows more gas to dissolve (according to Henry’s Law).
The concentration of polluted substances in out-going gas streams can never become lower than that
permitted by the equilibrium between the gas phase and the scrubbing liquid.
In practice, a scrubber consists of three parts: An absorption section, a droplet collector and a recirculation
tank with pump.
Design data:
The liquid-gas ratio (L/G) in a scrubber is the relationship between the scrubbing liquid flow rate and the
gas stream flow rate. For dimensioning purposes, and to evaluate the workings of a scrubber, it is important
to know how much liquid is required per m³ to realise the required residual emission. The L/G ratio is not
only determined by the required residual emission, but is also partly determined by the concentration of the
to-be-removed substance(s) in the gas stream and the in and out-going liquid streams. The L/G ratio in a
particular situation is thus determined by the selected scrubbing system, the properties of the to-be-
cleaned gas, the scrubbing liquid and the to-be-removed component(s) and the requirements set for
residual emissions.
Variants
Flow direction gas and liquid
Scrubbers can be distinguished in terms of the flow direction of the gas in relation to the liquid. A
distinction is made between counter-flow, co-current and cross-flow scrubbers.
In counter-flow scrubbing the scrubbing liquid and the to-be-cleaned gas flow in opposite directions. The
main advantage of counter-flow scrubbing is that the cleaner the gas becomes, the lower the pollutant
concentration in the scrubbing liquid becomes - whereby the driving force is maintained throughout the
column. This type of scrubber is, for example, particularly suited to irregular and peak emissions. The
counter-flow set-up allows high concentration peaks to be better dealt with.
In co-current scrubbers, the gas and liquid stream move in the same direction. They are less e!ective than
counter-flow scrubbers. However, the advantage they o!er is that they are suited to high gas and liquid
loads. Co-current scrubbers have a more compact construction and are normally considered when limited
space is available and a lower yield is acceptable. Further, they are e!ective as an initial scrubbing stage for
a counter-flow scrubber, for example, when the gas flow needs to be cooled or partly separated.
In cross-current scrubbers, the gas and the liquid move across one another. For vapour-like components,
the liquid will normally flow in a downward direction and gases will flow horizontally. In dust scrubbing, the
sprayers will be horizontal to the gas flow. This type of scrubber is more compact than a counter-current
scrubber, if one works with a multi-stage set-up, and uses less electricity. A cross-current scrubber is
suited to emissions with known maximum concentrations, thus allowing it to be dimensioned appropriately.
In case of very high concentration peaks, for which the scrubber has not been dimensioned, the scrubbing
liquid will be saturated before it reaches the bottom of the packing. This means that a part of the air will
not be (fully) treated, with yield loss as a result.
Gas scrubbers can also be distinguished by the set-up of the wash section, e.g. with or without a built-in
device. The built-in device could be a bulk or structured packing or a construction with plates or a rotating
disk. The main layout can be further broken down as follows:
Spray towers: In spray towers the water is dispersed in fine droplets, normally via sprayers at the top of
the scrubber, while the gas is fed from underneath – thus in counter-current. Set-up is also possible in
co-current or cross-current formats. Can also be used as a dust scrubber.
Jet scrubbers: In a jet scrubber, the gas and scrubbing liquid are brought into contact with one another in
a co-current direction, in accordance with the workings of a water jet pump. In the wash section, the jet
breaks down into droplets, which creates a large phase interface. In the next area, the gas and the liquid
are separated.
Venturi
VITO uses scrubber: A venturi
necessary cookies. In scrubber consists
order to optimize of user
your a converging
experiencesection, a throatwe(the
on our website, alsonarrowest part
want to use of the
optional cookies fo
venturi tube) and a di!user. The gas flows through the venturi tube and reaches top speed in the throat
permission.
section. Thereafter, the gas passes into the di!user where the speed of the gas drops once again. The
Accept Decline
liquid is added to the gas flow either in the throat section or prior to it. Intensive mixing takes place
between the gas and the liquid in the throat section of the venturi tube. Due to the high speed realised
by the gas and liquid, the water is broken down into fine water droplets. Can also be used as a dust
scrubber
Plate column: A plate column is a column which is divided into segments by perforated plates. The
perforations have been designed in a way that forces the to-be-cleaned gas to bubble through a sealed
fluid layer on the plates, which is where absorption takes place.
Packed columns: Scrubbers with packed columns are filled with structured or unstructured packing
material. This material has a high specific surface area, which means a large phase interface is created
between the gas and the liquid. The scrubbing liquid flows downwards in a thin film over the packing
material, while the gas flows upwards through the remaining free space. In scrubbers with packed
columns, the liquid and the gas do not disperse into one another.
Rotation scrubber: In rotation scrubbers the scrubbing liquid is, via a fast-rotating spray, broken down
into small droplets, whereby a large contact area is created between droplets and gas. As a result of the
rotating sprayer, dust particles are forced to the sides of the scrubber and separated. Rotation scrubbers
are primarily used as dust scrubbers.
Ionisation scrubbers: These are a modified form of wet E filters. They are scrubbers with a built-in
ionisation phase.
The compatibility of the various scrubber types is determined by the properties of the to-be-cleaned gas.
If it contains a lot of solid particles or other components that could lead to cake-forming and blockage,
then a scrubber will be selected which is less sensitive to these factors - such a various scrubbers without
built-in devices.
Another possibility is to install a multi-stage scrubbing system, where the various stages are designed to
remove di!erent components. Plate columns are primarily used in the chemicals industry. They are rarely
used for environmental purposes due to the high investment costs.
Packed columns are normally used during absorption applications. One must choose between a bulk
packing or a structured packing. Bulk packings are cheaper, have a lower specific surface area and a higher
pressure drop. Structured packings, on the other hand, are a little bit more expensive than bulk packings,
have a high specific surface area and a lower pressure drop. The choice between the two types of packing is
determined by the to-be-treated gas stream. If there is a considerable risk of blockage due to dust and/or
biological growth, then an open packing – which is easier to clean - will be used. In other cases, a packing
with a smaller opening and a higher specific surface area will be used.
Acid scrubber
Alkaline scrubber
Alkaline oxidizing scrubber
Wet lime scrubber
Bioscrubber
Water scrubber: For substances that dissolve well in water, such as certain alcohols, no additional
substances are added.
Oil scrubber: This is possible for lipophilic products such as, for example, halogenated solvents
E!ciency
Depending on the to-be-removed component, residual emission, scrubbing liquid and the type of
application, yields in excess of 99% can be realised.
In asphalt plants, a yield of almost 98% has been registered for VOC’s. In terms of odour reduction, the yield
was maximum 23%. Considering the poor water solubility of VOC’s in flue gases, it is expected that yields
will deteriorate due to the low solubility, whereby the VOC will no longer be collected [8].
Boundary conditions
Flow rate: 50 – 500 000 Nm3/h
Temperature: 5 - 80 °C
Dust: < 10 mg/m3
Auxiliary materials
Water. Water use is determined by the in and out-going concentrations of gaseous components.
Reagents: Acids, alkalis, bleach, peroxide etc. depending on used variant.
Apart from water, no specific chemicals are needed for the removal of HC1 from flue gases.
Environmental aspects
Waste water. In most cases, waste water needs to be purified. In certain cases it can be evaporated and
reprocessed for the recuperation or recovery of products.
Acidic leachate will be partly drained (depending on pH). The leachate is supplemented by water. The
released leachate must be treated prior to being discharged.
Energy use
Energy use lies between 0.2 – 1.0 kWh/1 000 Nm3/h (excluding ventilator) [1].
Cost aspects
Investment
2 000 – 30 000 EUR for 1 000 Nm³/h (recirculation scrubber with pomp; costs greatly determined
by application) [1].
For the removal of HCl from flue gases from a chemicals company, with a flue gas flow rate up to 3 000
Nm³/h, the investment costs for a neutral washer (water) and a ventilator, amount to 62 500 EUR [6]
Operating costs
Personnel costs: ca. 5 000 EUR per year (estimated at 4 hours per week) [1].
Auxiliary and residual materials: Determined by in-going concentrations and required residual
emissions.
Disadvantages
Applications
Broad range of applications in:
Chemicals industry
Waste incineration installations;
Pharmaceutical industry
Storage and transfer of chemicals
Surface treatment
References
1. Factsheets on Air-emission reduction techniques, www.infomil.nl, Infomil
2. Common waste water and waste gas treatment and management systems in the chemical sector. BREF
document, European IPPC Bureau, http://eippcb.jrc.es
3. Elslander H., De Fré R., Geuzens P., Wevers M. (1993). Comparative evaluation of possible gas purification
systems for the combustion of household waste. In: Energie & Milieu, 9
4. Vanderreydt I. (2001). Inventory of the waste incineration sector in Flanders. Vito, 2001/MIM/R/030
5. Work-book on environmental measures: Metal and electro-technical industry (1998 ). VNG publishers
6. Supplier information
7. VDI 3679, Nassabscheider, Abgasreinigung durch absorption
8. A. Jacobs, L. De Bock en R. Dijkmans., Best Available Techniques for asphalt plants, November 2001
9. J. Van Deynze, P. Vercaemst, P. Van den Steen and R. Dijkmans., Best Available Techniques for paint,
varnish and printing ink production, 1998