A928/A928M − 14
A 5.22 Flux Cored Corrosion-Resisting Chromium and required radiography, and the exposed weld surface shall be
Chromium-Nickel Steel Electrodes examined visually for conformance to the requirements of
A 5.30 Consumable Weld Inserts for Gas Tungsten Arc 6.2.3. Welds made by procedures using backing strips or rings
Welding that remain in place are prohibited. Welding procedures and
welding operators shall be qualified in accordance with the
3. Terminology ASME Boiler and Pressure Vessel Code, Section IX.
3.1 Definitions: 6.2.2 Except as provided in 6.2.2.1 and 6.2.2.2, welds shall
3.1.1 The definitions in Specification A999/A999M and be made in their entirety by processes involving the deposition
Terminology A941 are applicable to this specification. of filler metal.
6.2.2.1 For Class 4 pipe using multiple passes, it is permit-
4. Ordering Information ted to make the root-pass without the addition of filler metal.
4.1 It shall be the responsibility of the purchaser to specify 6.2.2.2 For Class 4 pipe, it is permitted that the weld surface
all requirements that are necessary for product under this exposed inside the pipe be the result from a single pass made
specification. Such requirements to be considered include, but from the inside of the pipe without the addition of filler metal.
are not limited to, the following: 6.2.2.3 All single-welded pipe shall be radiographed com-
4.1.1 Quantity (feet, metres, or number of lengths), pletely.
4.1.2 Name of material (electric-fusion-welded pipe), 6.2.3 The weld surface on either side of the weld may be
4.1.3 Grade (see Table 1), flush with the base plate or may have a reasonably uniform
4.1.4 Class (see 1.3), crown, not to exceed 1⁄8 in. [3 mm]. It is permitted to remove
--`,,```,,,,````-`-`,,`,,`,`,,`---
4.1.5 Size (outside diameter and nominal wall thickness), any weld reinforcement, at the option of the manufacturer or by
4.1.6 Length (specific or random), agreement between the manufacturer and purchaser. The con-
4.1.7 End finish (section on ends of Specification A999/ tour of the reinforcement shall be reasonably smooth and free
A999M), of irregularities. The deposited metal shall be fused uniformly
4.1.8 Authorization for repair of plate defects by welding into the plate surface. No concavity of contour is permitted
and subsequent heat treatment without prior approval, if such is unless the resulting thickness of weld metal is equal to or
intended (see 13.3), greater than the minimum thickness of the adjacent base metal.
4.1.9 Specification designation, 6.2.4 Weld defects shall be repaired by removal to sound
4.1.10 Special requirements, metal and rewelding. Subsequent heat treatment and examina-
4.1.11 Statement invoking requirements of 13.4, if such is tion (that is, visual, radiographic, and dye penetrant) shall be as
intended, required on the original welds.
4.1.12 Circumferential weld permissibility (see Section 17),
6.3 Heat Treatment:
4.1.13 Supplementary Requirements (S1 through S4),
4.1.14 Applicable ASME Code, if known, 6.3.1 Unless otherwise stated in the order, heat treatment
4.1.15 For ASME Code Section III applications, the service shall be performed after welding and in accordance with the
classification intended, and requirements of Table 2.
4.1.16 Certification requirements (see section on certifica- 6.3.2 If the purchaser desires pipe without heat treatment
tion of Specification A999/A999M). subsequent to welding, the purchase order shall specify the
following condition:
5. General Requirements 6.3.2.1 No final heat treatment of pipe fabricated of plate
5.1 Material furnished to this specification shall conform to that has been heat treated as required by Table 2 for the
the applicable requirements of the current edition of Specifi- particular grade. Each pipe supplied under this requirement
cation A999/A999M unless otherwise provided herein. shall be stenciled with the suffix “HT-O.”
2
A928/A928M − 14
the ordered grade, the method of analysis shall be a matter of test. One specimen shall be bent with the inside surface of the
agreement between the purchaser and the manufacturer. pipe against the plunger, and the other with the outside surface
against the plunger.
8. Heat Analysis 12.2 For specified wall thicknesses over 3⁄8 in. [9.5 mm] but
8.1 The chemical analysis of the steel shall be determined less than 3⁄4 in. [19 mm], side-bend tests may be made instead
by the plate manufacturer and shall conform to the require- of the face and root-bend tests. For specified wall thicknesses
ments for the particular grade as prescribed in Specification 3⁄4 in. [19 mm] and over, both specimens shall be subjected to
3
TABLE 1 Pipe and Filler Metal Specifications
ASTM Plate A5.4 A5.9 A5.11 A5.14 A5.22 A5.30
UNS
GradeA Specification
Designation Class UNS Class UNS Class UNS Class UNS Class UNS Class UNS
No. and Grade
B B B B B B B B B B B B
S31200 ... A240 S31200
B B B B B B B B B B B B
S31260 ... A240 S31260
B B B B B B B B B B B B
S31500 ... A240 S31500
B B B B B B
S31803 ... A240 S31803 E2209... W39209... ER2209... S39209... E2209TOX... W39239...
B B B B B B B B B B B B
S32003 ... A240 S32003
B B B B B B
S32101 ... A240 S32101 E2307-XX S82371 ER2307 S82371 E2307TX-X
B B B B B B B B B B B B
S32202 A240 S32202
B B B B B B
S32205 2205 A240 S32205 E2209... W39209... ER2209... S39209... E2209TOX... W39239...
B B B B B B B B B B B B
S32304 2304 A240 S32304
4
B B B B B B B B B B B B
S32506 ... A240 S32506
B B B B B B
S32550 255 A240 S32550 E2553... W39553... ER2553... S39553... E2553TOX... W39533...
B B B B B B B B
S32750 2507 A240 S32750 E2594... W39594... ER2594... S32750...
B B B B B B B B B B B B
S32900 329C A240 type 329
B B B B B B B B B B B B
S32950 ... A240 S32950
B B B B B B B B B B B B
S32760 ... A240 S32760
B B B B B B B B B B B B
S32520 ... A240 S32520
A928/A928M − 14
B B B B B B
S81921 ... A240 S81921 E2209... W39209... ER2209... S39209... E2209TOX... W39239...
B B B B B B
S82121 ... A240 S82121 E2209... W39209... ER2209... S39209... E2209TOX... W39239...
B B B B B B B B B B B B
S82441 ... A240 S82441
A
Except as indicated, common name, not a trademark, widely used, not associated with any one producer.
--`,,```,,,,````-`-`,,`,,`,`,,`---
B
An AWS standard filler metal is not yet available for inclusion in this table.
C
A grade designation originally assigned by the American Iron and Steel Institute (AISI).
A928/A928M − 14
TABLE 2 Heat Treatment
UNS
GradeA Temperature, °F [°C] Quench
Designation
S31200 . . . 1920–2010 [1050–1100] rapid cooling in water
S31260 . . . 1870–2010 [1020–1100] rapid cooling in water
S31500 . . . 1800–1900 [980–1040] rapid cooling in air or water
S31803 . . . 1870–2010 [1020–1100] rapid cooling in air or water
S32003 . . . 1850–2010 [1010–1100] rapid cooling in air or water
S32101 . . . 1870 [1020] min rapid cooling in air or water
S32202 1870–1975 [1020–1080] rapid cooling in air or water
S32205 2205 1870–2010 [1020–1100] rapid cooling in air or water
S32304 2304 1700–1920 [925–1050] rapid cooling in air or water
S32506 ... 1870–2050 [1020–1120] rapid cooling in air or water
S32550 255 1900 [1040], min rapid cooling in air or water
S32750 2507 1880–2060 [1025–1125] rapid cooling in air or water
S32900 329B 1700–1750 [925–955] rapid cooling in air or water
S32950 ... 1820–1880 [990–1025] rapid cooling in air or water
S32760 ... 2010–2085 [1100–1140] rapid cooling in air or water
S32520 ... 1975–2050 [1080–1120] rapid cooling in air or water
S81921 ... 1760–2010 [960–1100] rapid cooling in air or water
S82121 ... 1830–2010 [1000–1100] rapid cooling in air or water
S82441 ... 1870 [1020] min rapid cooling in air or water
A
Except as indicated, common name, not a trademark, widely used, not associated with any one producer.
B
A grade designation originally assigned by the American Iron and Steel Institute (AISI).
plate of the same material as the pipe, which is attached to the thickness up through 0.165 in. (4.2 mm) shall be subjected to
end of the cylinder and welded as a prolongation of the pipe a nondestructive electric test as defined in 15.3.2.
longitudinal seam. 15.3.1 Hydrostatic Test—Each length of pipe shall be sub-
14.3 Tension test specimens shall be made in accordance jected to a hydrostatic test in accordance with Specification
with Section IX, Part QW-150 of the ASME Boiler and A999/A999M, unless specifically exempted under the provi-
Pressure Vessel Code and shall be one of the types shown in sion of 15.3.1.1. Pressure shall be held for a sufficient time to
QW-462.1 of that code. permit the inspector to examine the entire length of the welded
14.3.1 Reduced-section specimens conforming to the re- seam.
quirements given in QW-462.1(b) are permitted to be used for 15.3.1.1 With the agreement of the manufacturer, the pur-
tension tests on all thicknesses of pipe having outside diam- chaser is permitted to complete the hydrostatic test requirement
eters greater than 3 in. [76 mm]. with the system pressure test, which may be lower or higher
14.3.2 Turned specimens conforming to the requirements of than the specification test pressure, but in no case shall the test
QW-462.1(d) are permitted to be used for tension tests. pressure be lower than the system design pressure. Each length
14.3.2.1 If turned specimens are used as given in 14.3.2.2 of pipe furnished without the completed manufacturer’s hydro-
and 14.4, one complete set shall be made for each required static test shall include with the mandatory marking the letters
tension test. NH.
14.3.2.2 For thicknesses over 11⁄4 in. [32 mm], multiple 15.3.2 Nondestructive Electric Test—Each length of pipe
specimens shall be cut through the full thickness of the weld shall be subjected to a nondestructive electric test in accor-
with their centers parallel to the material surface and not over dance with Practice E426.
1 in. [25 mm] apart. The centers of the specimens adjacent to 15.3.2.1 For pipe up through NPS 4, the eddy-current test
material surfaces shall not exceed 5⁄8 in. [16 mm] from the shall be applied to the total pipe area. For pipe larger than NPS
surface. 4, the eddy-current test is permitted, at the option of the
14.4 The test specimens shall not be cut from the pipe or test producer, to be applied to the weld area only rather than the
plate until after final heat treatment. total pipe area.
5
A928/A928M − 14
16.4 For Class 5 pipe, radiographic examination shall be in 18. Product Marking
accordance with the requirements of the ASME Boiler and 18.1 In addition to the marking prescribed in Specification
Pressure Vessel Code, Section VIII, Division 1, latest edition, A999/A999M, the markings of each length of pipe shall
Paragraph UW-52. include the plate material designations as shown in Table 1, the
16.5 Radiographic examination is permitted to be per- marking requirements of 6.3 and 15.3, and Class 1, 2, 3, or 4,
formed prior to heat treatment. as appropriate (see 1.3).
17. Lengths 19. Keywords
17.1 Circumferentially welded joints of the same quality as 19.1 arc welded steel pipe; corrosive service; duplex
the longitudinal joints shall be permitted by agreement between (austenitic-ferritic) stainless steel; fusion welded steel pipe;
the manufacturer and the purchaser. steel pipe; welded steel pipe
SUPPLEMENTARY REQUIREMENTS
One or more of the following supplementary requirements shall apply when specified in the
purchase order. The purchaser may specify a different frequency of test or analysis than is provided
in the supplementary requirement. Subject to agreement between the purchaser and the manufacturer,
retest and retreatment provisions of these supplementary requirements may also be modified.
SUMMARY OF CHANGES
Committee A01 has identified the location of selected changes to this specification since the last issue,
A928/A928M–13, that may impact the use of this specification. (Approved October 1, 2014)
(1) Added UNS S32101 and UNS S82441 to Table 1 and Table (2) Revised heat treat temperature for S82121 in Table 2.
2.
Committee A01 has identified the location of selected changes to this specification since the last issue,
A928/A928M–11, that may impact the use of this specification. (Approved October 1, 2013)
--`,,```,,,,````-`-`,,`,,`,`,,`---
6
A928/A928M − 14
ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned
in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk
of infringement of such rights, are entirely their own responsibility.
This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the
responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should
make your views known to the ASTM Committee on Standards, at the address shown below.
This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above
address or at 610-832-9585 (phone), 610-832-9555 (fax), or [email protected] (e-mail); or through the ASTM website
(www.astm.org). Permission rights to photocopy the standard may also be secured from the Copyright Clearance Center, 222
Rosewood Drive, Danvers, MA 01923, Tel: (978) 646-2600; http://www.copyright.com/
--`,,```,,,,````-`-`,,`,,`,`,,`---