Brochure DHP - PU 3000 R1

Download as pdf or txt
Download as pdf or txt
You are on page 1of 17

IMPORT BY

DHP-3000
Flexible Polyurethane Foam
High pressure water Waterstops · Leakage Crack Waterstops
1 Component Type Polyurethane Waterstops for Filling
PU Injection Foam for Water-stop

Product Information

This product is Hydrophilic (hydrophile property)


waterstop material which is very effective for
leakage of underground structure. And it is also
effective for extension joint section and structure
that is vulnerable by vibration. It is mainly applied
in place where lots of water is. DHP-3000 is 1
component type polyurethane resin and has 700%~800% of foaming rate. It forms high
density and high elasticity Cell. Especially, it does not turns into yellowish color in other
word no discoloration. This is excellent product.

Characteristics
It forms high density and elasticity foam and its water proof is excellent.
With its low viscosity, it is very easy to inject of hairline crack. It has excellent
waterstop effect.
It is hydrophile property that reacts even with very small amount of moisture. It forms
Foam and it make possible to waterstop minute crack thoroughly.

Foam also has excellent elasticity that accepts movement of concrete. Therefore it
is very effective once it is applied on the place where vibration is severe.

Usage
Waterstops crack leakage spot and joint section of all the concrete structure that
—
accompanies any movements.

Application Area

Normally it can be applied to waterstop for crack section and joint section of concrete
structures where vibration is severe. It can be applied on following places.

- Waterstops for leaking section of basement parking lot and underground concrete structure.
- Waterstops for creacked leakage section of structure that has vibration.
- Waterstops for leakage of concrete joint section.
- Waterstops for leakage section and water waste treatment that accompanies any movements.
- Waterstops for leakage section of parking lot ramp and for underground electric line passage.
Since 1989

PT. PENETRON INDONESIA


Rukan Fatmawati Mas Blok III No. 306, Jl. Fatmawati No.20, West Cilandak, Cilandak, South Jakarta City,
Jakarta 12430 Telp/Fax : 021-7659179 / 021-75908750
IMPORT BY
DHP-3000 Property Data

Classification Base Value Test Method

Exterior Appearance Yellow Transparent Liquid


PU Injection Foam for Water-stop

Mixing Rate 1 Component Type

Viscosity( mPa,s ) 300 ± 50 KS M 2555

Specific Gravity 1.12 ± 0.05 KS M 0004

Tensile Strength(N/㎟) 0.5 or over KS M 3734

Elongation Percentage 80% or over KS M 6518

Packing Unit 20KG / 10KG

Foaming Percentage 800%

Reaction Data on a Different Temperature Conditions

Temperature Conditions 5℃ 15℃ 25℃ 30℃

Foaming Starts(sec) 35 27 16 13

Foaming Ends(sec) 215 165 126 105

Foaming Percentage 800 840 870 880

Viscosity 510 360 250 195

Using Materials

Since 1989 1)High Pressure Injection Packer 2)Injecting Equipment for polyurethane
resin injection

PT. PENETRON INDONESIA


Rukan Fatmawati Mas Blok III No. 306, Jl. Fatmawati No.20, West Cilandak, Cilandak, South Jakarta City,
Jakarta 12430 Telp/Fax : 021-7659179 / 021-75908750
IMPORT BY
1) It is specially designed to endure high pressure that is applied. Injected resin won't flow
backward and this packer is also specially designed not to leak resin around stabilized
and fixed packer.
2)This is 1 component type high-pressure injection equipment that is specially manufa ctured
to fill on a leakage and fracture spot by using polyurethane foam and epoxy injection material.
PU Injection Foam for Water-stop

Construction Guideline

• Preforation
Perforate around leaking and fracturing spot and fixate packer. Normally when injecting
polyurethane foam, it is injected through packer generally. During the perforation use
hammer drill and make holes with same diameter. External diameter of Drill Bit should be
10mm. Perforation angle between concrete surface and crack should keep 45 degree
angle or under. If it is possible, then make position of perforation hole that contacts crack
as thick as 1/2~2/3 of concrete thickness. If the concrete thickness is less than 10cm
then directly perforate to fractured spot. If the thickness is 10cm~50cm, perforate in the
distance of 1/5 thickness of the concrete. Conduct it around fractured spot with 20cm
interval and perforate in zigzag.

• Packer Installation
Select the suitable packer out of various kinds of packers that suits the most according to
field circumstance. And use T-box and firmly tighten up the packer to perforated hole and
make sure not to bounce off by counter pressure. (It might get damaged if it is tightened
too hard.)

• Polyurethane Injection
Inject DHP-3000 Flexible Polyurethane Foam by using high-pressure injection equipment or grease
gun. Maintain initial injection pressure about 40kg/cm² and keep injecting until waterstop material
flows out through fractured spot. Halt injecting for a few minutes when DHP-3000 Flexible Polyur-
ethane Foam flows out grossly between cracks during first PACKER injection, then injected foam
will foam completely and it will become as seal material. For next injection operation, DHP-3000
Flexible Polyurethane Foam will fill up the cracks well enough. After 5 minutes, start to
re-inject. You can ignore the chemicals that leaks out little bit, even you can check injection
status. If the crack is very big then conduct sealing before injection.

If the waterstop is injected properly, make sure to check the following steps in orders.

-Does the water inside of the crack come out caused by Polyurethane Foam Waterstop injection!
-Does the injected Foam react with water and come out from the cracks after gradually foaming!
-Finally, does the undiluted liquid of Polyurethane Foam slides out between the cracks before
it starts foaming!

If it is so then the injection is properly done.

Since 1989

PT. PENETRON INDONESIA


Rukan Fatmawati Mas Blok III No. 306, Jl. Fatmawati No.20, West Cilandak, Cilandak, South Jakarta City,
Jakarta 12430 Telp/Fax : 021-7659179 / 021-75908750
IMPORT BY
• Removing Packer
Use vice pliers as a tool or bend off or use hammer to remove it.
If there is wet spot left then inject Polyurethane Foam again.

• Finishing Opreation
PU Injection Foam for Water-stop

Remove DHP-3000 Flexible Polyurethane Foam that is smeared around cracked


area. Seal with flexible sealing material (DH-CF30 Crack Cover Material)

Cleaning
All the equipments and tools that are used for this operation should be cleaned when the
operation is finished. Detergent such as M.E.K, Acetone, Xylene, Toluene and urethane
thinner should be used when cleaning. If the Foam is smeared on your skin during the
performance, wash it immediately with flowing water. Used injection equipment should need
to be stored after filling up the hose, pump and medical fluid container with Engine Oil and
Oil Pressure Oil.

Cautions

When you treating medical fluid, make sure you wear protective helmet, goggle clothes
and other protective devices.

If the medical fluid is smeared on your skin, wash it off immediately and clean up with
soapy water.

All the hand tools and equipments that are used for this operation should be cleaned with
thinner thoroughly.

If you are working in sealed room, then make sure to conduct constraint ventilation for
clean air.

If the medical fluid is smeared on your skin and causes skin trouble, then you should go
see specialist for prescription.

If the temperature is below 5℃, then you must artificially raise up the temperature of
medical fluid. This way you can get proper Pot Life.

If the atmosphere temperature is high and the area is humid, Pot Life of medical fluid
quickens. On the contrary, Pot Life will slow down in low temperature area.

Be aware of it before you conduct the operation.

Storing Method
Recommended temperature for storage is 10~25℃ with no moisture. Store it in cool area.
Storing period is about 6 months in sealed condition however it can be corrupted according
to storing area and conditions. Preferably use it as soon as possible.
This product is packed with nitrogen gas. Once seal is removed, then use it as soon as
possible.

Since 1989

PT. PENETRON INDONESIA


Rukan Fatmawati Mas Blok III No. 306, Jl. Fatmawati No.20, West Cilandak, Cilandak, South Jakarta City,
Jakarta 12430 Telp/Fax : 021-7659179 / 021-75908750
IMPORT BY PT. PENETRON INDONESIA
Rukan Fatmawati Mas Blok III No. 306, Jl. Fatmawati No.20, West Cilandak, Cilandak,
South Jakarta City, Jakarta 12430 Telp/Fax : 021-7659179 / 021-75908750

Material Safety Data Sheet

1. Product and company identification

A. Product Name: DHP-3000


B. Recommended use of the chemical and restrictions on use:
- Recommended use of the chemical: Blocking effect of water
- Restrictions on use : Not determined
C. Manufacturer/Supplier/Distributor Information/Import by
- Name : PT. PENETRON INDONESIA
- Adress : Rukan Fatmawati Mas Blok III No. 306, Jl. Fatmawati, West Cilandak, Cilandak South Jakarta
- Emergency phone number : TEL. 021-7659179, FAX. 021-75908750

2. Hazards identification

A. Classification of the substance and mixture :


Flammable liquid : Category 2.
Eye damage/irritation : Category 2A
Specification target organ toxicity following single exposure : Cat.3
Specific target organ toxicity following repeat exposure : Cat. 3
Aspiration hazard : Cat.2

B. Label elements including precautionary statements


- Symbol:

- Signal Word: Dangerous

- Hazard statement :
H225 Highly flammable liquid and vapor
H319 Causes serious eye irritation
H332 Harmful if inhaled
H336 May cause drowsiness or dizziness
H370 Causes damage to organs

- Precautionary statement(Prevention)
P210 Keep away from heat/sparks/open flames/hot surfaces
P233 Keep container tightly closed
P240 Ground/Bond container and receiving equipment
P241 Use explosion-proof electrical/lighting
P242 Use only non-sparking tools

2013. 8. 29 Page 1/5


IMPORT BY PT. PENETRON INDONESIA
Rukan Fatmawati Mas Blok III No. 306, Jl. Fatmawati No.20, West Cilandak, Cilandak,
South Jakarta City, Jakarta 12430 Telp/Fax : 021-7659179 / 021-75908750

- Precautionary statement(Response)
P303+P361+P353 IF ON SKIN : Take off immediately all contaminated clothing, wash with plenty of soap and
water
P370+P378 In case of fire : use water/water spray/carbon dioxide/sand/foam/alcohol resistant foam/chemical
powder for extinction.
P307+P311 If exposed : call a Poison center or doctor/physician
P304+P340 Remove person to fresh air and keep comfortable for breathing
P312 Call a Poison center or doctor/physician

- Precautionary statement(Storage)
P403+P235 Store in well-ventilated place. Keep container tightly closed. Store locked up.
P405 Store locked up.
P403+P233 Store in well-ventilated place. Keep the container tightly closed.
Precautionary statement(Disposal)
P501 Disposal of contents/container in accordance with local, regional, national and international regulations.

C. Other
NFPA
- Health : 1
- Flammability : 3
- Reactivity : 0

3. Composition/Information on ingredients

Chemical Name Include (%) Chemical structure CAS No.

Polyurethane resin 78~82 - -

Acetone 18~22 CH3COCH3 67-64-1

et. ac 0.5~1.0 - -

4. First aid measures

A. General advice : Immediately remove contaminated clothing


B. If inhaled : keep patient calm, remove to fresh air, seek medical attention
C. On skin contact : Remove contaminated clothing, shoes immediately. Wash with soap of large amount water
D. On contact with eyes : Washed eyes immediately with plenty of water and until no evidence of chemical
remains. consult an eye specialist.
E. On ingestion : Immediately rinse mouth and then drink plenty of water, do not induce vomiting, seek
medical attention

5. Fire-Fighting measures

A. Suitable (and unsuitable) extinguishing media: Dry powder, carbon dioxide, alcohol-resistant foam,
water spray
B. Specific hazards arising from the chemical (e.g. nature of any hazardous combustion products):
- carbon dioxide, carbon monoxide, hydrogen cyanide, nitrogen oxides, isocyanate

2013. 8. 29 Page 2/5


IMPORT BY PT. PENETRON INDONESIA
Rukan Fatmawati Mas Blok III No. 306, Jl. Fatmawati No.20, West Cilandak, Cilandak,
South Jakarta City, Jakarta 12430 Telp/Fax : 021-7659179 / 021-75908750

C. Special protective equipment


- wear self-contained breathing apparatus and chemical-protective clothing

6. Accidental release measures

A. Personal precautions, protective equipment and emergency procedures


- Avoid contact with eyes and clothing. Avoid contact with liquid and vapors.
B. Environmental precautions and protective procedures:
- Do not empty into drains. Do not discharge into the sub sol/soil
C. Methods and materials for containment and cleaning up:
- Cover with absorbent or contain.
- Collect for disposal.
- Observe government regulations.

7. Handling and storage

A. Precautions for safe handling:


- Do not get in eyes, on skin, on clothing, Avoid breathing vapor, aerosol and mist.
- Use with adequate ventilation. Wash thoroughly after handling.
B. Conditions for safe storage (including any incompatibilities):
- Keep away from heat and flame. Keep container closed .

8. Exposure controls & personal protection

A. Control parameters (e.g. occupational exposure limit values, biological limit values):
- Acetone basis
- TWA value 500 ppm(ACGIH)
- TWA 750ppm(OSHA)
B. Appropriate engineering controls:
- No exposure limits have been established
C. Personal protective equipment
- Respiratory protection: Combination filter for gases/vapours of organic compounds and solid and liquid
particles
- Eye protection: Safety glasses with side shields.
- Hands protection: Chemical resistant protective gloves
- Body protection: Chemical protective clothing and safety shoes.

9. Physical and chemical properties

A. Appearance (physical state, color etc): liquid


B. Odour: like ether or mint
C. Odour threshold: No information
D. pH(n): not applicable

2013. 8. 29 Page 3/5


IMPORT BY PT. PENETRON INDONESIA
Rukan Fatmawati Mas Blok III No. 306, Jl. Fatmawati No.20, West Cilandak, Cilandak,
South Jakarta City, Jakarta 12430 Telp/Fax : 021-7659179 / 021-75908750

E. Meting point/freezing point: -15℃


F. Initial boiling point and boiling range: 56℃
G. Flashing point : -5℃
H. Evaporation rate: (Butyl acetate=1): No available
I. Flammability (solid, gas): flammable liquid
J. Upper/lower flammability or explosive limits: No information
K. Vapor pressure: 180mmHg at 20℃
L. Solubility: No information
M. Vapor density: 2.0
N. Relative density: 1.10 ~ 1.20
O. Partition coefficient: n-octanol/water: No information.
P. Auto-ignition temperature: >465℃
Q. Decomposition temperature: No information

10. Stability and reactivity

A. Chemical stability and possibility of hazardous reactions: Stable at ambient & atmosphere conditions
B. Conditions to avoid (e.g. static discharge, shock or vibration, etc): Will not occur.
C. Substances to avoid : Avoid moisture, acids, alcohols, amines, eater, alkalines
D. Corrosion to metals : No corrosive effect on metal
E. Hazardous decomposition products: Carbon dioxide, nitrogen oxide.

11. Toxicological information

A. Acute toxicity Experimental/calculated data :


- LD50 rat(oral) : >5,800 mg/kg
- LC50 rabbit(dermal) : 17,700 ppm
- LD50 rat(by inhalation) : >70.9mg/L/4h

B. Health hazards information


- Skin corrosive/irritant: No information
- Serious eye damage/eye irritation: No information
- Respiratory sensitization: The substance may cause sensitization of the respiratory tract
- Skin sensitization: No information
- Carcinogenicity: ACGIH Group 4
- Germ Cell Mutagenicity : No information
- Reproductive toxicity: No information
- Specific target organ toxicity (single exposure): Cause respiratory irritation. Exposed to lethal
concentration, may cause anesthesia and lung damages
- Specific target organ toxicity (repeated exposure): No information
- Germ Cell Mutagenicity : No information

2013. 8. 29 Page 4/5


IMPORT BY PT. PENETRON INDONESIA
Rukan Fatmawati Mas Blok III No. 306, Jl. Fatmawati No.20, West Cilandak, Cilandak,
South Jakarta City, Jakarta 12430 Telp/Fax : 021-7659179 / 021-75908750

12. Ecological information

A. Aquatic and terrestrial ecotoxicity: No information


B. Persistence and Biodegradability: No information
C. Bioaccumulative potential: No information
D. Mobility in soil: No information
E. Other adverse effects: No information

13. Disposal considerations

A. Method of disposal : Disposal required in compliance with all waste management related law stated.
B. Contaminated packaging : Consider the notice law stated prior to dispose.

14. Transport information

A. UN number: 1866
B. UN proper shipping name: RESIN SOLUTION flammable
C. Transport hazard class: 3
D. Packing group (if applicable): 2
E. Marin pollution (yes/no): Not applicable
F. Special precaution which a user to be aware of or needs to comply with in connection with transport or
conveyance either within or outside their premises: Not applicable

15. Regulatory information

A. Industrial Safety and Health Act: Working environment measurement materials


B. Toxic Chemical Control Act: Accident precaution chemical, Toxical chemical
C. Dangerous Material Safety Control Act: 4 class petroleum
D. Wastes Management Act: Not applicable
E. Other requirements in domestic and other countries: Not applicable

16. Other information

Disclaimer of responsibility: This document is generated for the purpose of distributing health,
Safety, and environmental data. It is not a specification sheet nor shoulder any displayed data
Be construed as a specification. The information on this MSDS was obtained from sources which
We believe are reliable. However the information is provided without any warranty, expressed
Or impelled, regarding is correctness. Some information presented and conclusion drawn herein
Are from sources other than direct test data on the substance itself.
The conditions or methods of handling, storage, use and disposal of the product are beyond
Our control and may be beyond our knowledge.
For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss,
Damage, or expense arising out of or in any way connected with handling, storage, use, or disposal
Of this product. If the product is used as a component in another product, this MSDS
Information may not be applicable.

2013. 8. 29 Page 5/5

You might also like