Indoor Unit/Outdoor Unit: Split Type Air Conditioner
Indoor Unit/Outdoor Unit: Split Type Air Conditioner
Indoor Unit/Outdoor Unit: Split Type Air Conditioner
RAS-60YHA/RAC-60YHA
RAC-60YHA RAS-60YHA
– 1 –
SAFETY PRECAUTION
● Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit.
● Pay special attention to signs of “ ! Warning” and “ ! Caution”. The “Warning” section contains matters which,
if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may
result in serious consequences if not observed properly. Please observe all instructions strictly to ensure safety.
● The sign indicate the following meanings.
Make sure to connect earth line. The sign in the figure indicates prohibition.
● Do not insert a finger, a rod or other objects into the air outlet or inlet. As the fan
W is rotating at a high speed, it will cause injury. Before cleaning, be sure to stop the
A operation and turn the breaker OFF.
R
N ● Do not use any conductor as fuse wire, this could cause fatal accident.
I
N
● During thunder storm, disconnect and turn off the circuit breaker.
G
● This unit has UV LED which emits ultra violet light.
AVOID DIRECT EYE EXPOSURE.
– 2 –
PRECAUTIONS DURING OPERATION
ENGLISH
● The product shall be operated under the manufacturer specification and
not for any other intended use.
● Do not attempt to operate the unit with wet hands, this could cause fatal
accident.
● When operating the unit with burning equipments, regularly ventilate the
room to avoid oxygen insufficiency.
● Do not direct the cool air coming out from the air-conditioner panel to face
household heating apparatus as this may affect the working of apparatus
such as the electric kettle, oven etc.
● Please ensure that outdoor mounting frame is always stable, firm and
without defect. If not, the outdoor unit may collapse and cause danger.
● Do not splash or direct water to the body of the unit when cleaning it as this
may cause short circuit.
● Do not use any aerosol or hair sprays near the indoor unit. This chemical
can adhere on heat exchanger fin and blocked the evaporation water flow
! to drain pan. The water will drop on tangential fan and cause water splashing
out from indoor unit.
C
A ● Please switch off the unit and turn off the circuit breaker during cleaning, the
U high-speed fan inside the unit may cause danger.
T
I
O ● Turn off the circuit breaker if the unit is not to be operated for a long period.
N
● Do not put water container (like vase) on the indoor unit to avoid water
dripping into the unit. Dripping water will damage the insulator inside the unit
and causes short-circuit.
● Do not place plants directly under the air flow as it is bad for the plants.
● When operating the unit with the door and windows opened, (the room humidity is always above
80%) and with the air deflector facing down or moving automatically for a long period of time,
water will condense on the air deflector and drips down occasionally. This will wet your furniture.
Therefore, do not operate under such condition for a long time.
● If the amount of heat in the room is above the cooling or heating capability of the unit (for
example: more people entering the room, using heating equipments and etc.), the preset room
temperature cannot be achieved.
● This appliance is not intended for use by young children or infirm persons unless they have been
adequately supervised by a responsible person to ensure that they can use the appliance safely.
● Young children should be supervised to ensure that they do not play with the appliance.
– 3 –
NAMES AND FUNCTIONS OF EACH PART
INDOOR UNIT
Air filter
To prevent dust from coming into the indoor unit.
(Refer page 21)
Front panel
Remote controller
Send out operation signal to the indoor unit. So as to
operate the whole unit.
(Refer page 6)
OUTDOOR UNIT
Drain pipe
Condensed water drain to outside.
Air outlet
! CAUTION
• When heating operation, drain or
defrosted water flows out from outdoor
unit. Don’t close drain outlet portion
in chilly area so as not to freeze these.
MODEL NAME AND DIMENSIONS
– 4 –
ENGLISH
INDOOR UNIT INDICATORS
FILTER LAMP
When the device is operated for a total of about 200
hours, the FILTER lamp lights to indicate that it is time
to clean the filter. The lamp goes out when the
“ (AUTO SWING)” button is pressed while the
device is on “STANDBY MODE”.
HITACHI
OPERATION LAMP
This lamp lights during operation.
The OPERATION LAMP flashes in the following cases
during heating.
(1) During preheating
For about 2–3 minutes after starting up.
(2) During defrosting
Defrosting will be performed about once an hour
when frost forms on the heat exchanger of the
outdoor unit, for 5–10 minutes each time.
TIMER LAMP
This lamp lights when the timer is working.
OPERATION INDICATOR
TEMPORARY
SWITCH
TEMPORARY
SWITCH
TEMPORARY SWITCH
● Use this switch to start and stop when the remote controller does not work.
● By pressing the temporary switch, the operation is done in automatic mode.
– 5 –
NAMES AND FUNCTIONS OF REMOTE CONTROL UNIT
REMOTE CONTROLLER
● This controls the operation of the indoor unit. The range of control is about 7 meters. If indoor lighting is controlled
electronically, the range of control may be shorter.
This unit can be fixed on a wall using the fixture provided. Before fixing it, make sure the indoor unit can be controlled
from the remote controller.
● Handle the remote controller with care. Dropping it or getting it wet may compromise its signal transmission capability.
● After new batteries are inserted into the remote controller, the unit will initially require approximately 10 seconds to
respond to commands and operate.
– 6 –
VARIOUS FUNCTIONS
ENGLISH
■ Auto Restart Control
● If there is a power failure, operation will be automatically restarted when the power is resumed with previous
operation mode and airflow direction.
(As the operation is not stopped by remote controller.)
● If you intend not to continue the operation when the power is resumed, switch off the power supply.
When you switch on the circuit breaker, the operation will be automatically restarted with previous operation
mode and airflow direction.
Note: 1. If you do not require Auto Restart Control, please consult your sales agent or OFF by remote
control.
2. Auto Restart Control is not available when Timer or Sleep Timer mode is set.
AUTOMATIC OPERATION
The device will automatically determine the mode of operation, HEAT, COOL or DEHUMIDIFY depending on
the current room temperature. The selected mode of operation will change when the room temperature varies.
Press the FUNCTION selector so that the display indicates the (AUTO) mode
of operation.
1 ● When AUTO has been selected, the device will automatically determine the
mode of operation, HEAT, COOL or DEHUMIDIFY depending on the current
room temperature.
● If the mode automatically selected by the unit is not satisfactory, manually
change the mode setting (heat, dehumidify, cool or fan).
RESET
■ As the settings are stored in memory in the remote controller, you only have to
press the (START/STOP) button next time.
You can raise or lower the temperature setting as necessary by maximum of 3°C.
°C
Press the temperature button and the temperature setting will
change by 1°C each time.
● The preset temperature and the actual room temperature may vary somewhat
depending on conditions.
● The display does not indicate the preset temperature in the AUTO mode. If you
change the setting, the indoor unit will produce a beep.
– 7 –
HEATING OPERATION
● Use the device for heating when the outdoor temperature is under 21°C.
When it is too warm (over 21°C), the heating function may not work in order to protect the device.
● In order to keep reliability of the device, please use this device above –15°C of the outdoor temperature.
Set the desired FAN SPEED with the (FAN SPEED) button
(the display indicates the setting).
(AUTO): The fan speed is HI at first and varies to
MED or LOW automatically when the preset
RESET
2 temperature has been reached.
(HI) : Economical as the room will become warm
quickly.
But you may feel a chill at the beginning.
(MED) : Fan speed slow.
(LOW) : Fan speed slower.
■ As the settings are stored in memory in the remote controller, you only
have to press the (START/STOP) button next time.
– 8 –
DEHUMIDIFYING OPERATION
ENGLISH
Use the device for dehumidifying when the room temperature is over 16°C.
When it is under 15°C, the dehumidifying function will not work.
■ Dehumidifying Function
When the room temperature is higher than the temperature setting: The device will dehumidify the room,
reducing the room temperature to the preset level.
When the room temperature is lower than the temperature setting: Dehumidifying will be performed at
the temperature setting slightly lower than the current room temperature, regardless of the temperature
setting. The function will stop (the indoor unit will stop emitting air) as soon as the room temperature
becomes lower than the setting temperature.
– 9 –
COOLING OPERATION
Use the device for cooling when the outdoor temperature is 21-43°C.
If in doors humidity is very high (80%), some dew may form on the air outlet grille of the indoor unit.
Set the desired FAN SPEED with the (FAN SPEED) button
(the display indicates the setting).
– 10 –
FAN OPERATION
ENGLISH
You can use the device simply as an air circulator. Use this function to dry the interior of the indoor
unit at the end of summer.
FAN SPEED (AUTO) ..... When the AUTO fan speed mode is set in the cooling/heating operation:
– 11 –
HOW TO SET THE TIMER
OFF TIMER
RESET
ON TIMER
OFF-Timer 1 Press the (OFF-TIMER)
button. The (OFF) mark blinks
RESERVE on the display.
AM
CANCEL Start STOP
ON-Timer
Stop Start
1 Press the (ON-TIMER)
button the (ON) mark blinks
on the display.
● The device will turn on
at the designated times.
AM
ON/OFF-Timer 1 Press the (ON-OFF) 2 Set the turn-off time 3 Press the (ON-
button so that the (OFF) with the TIMER control TIMER) button so that the
mark blinks. button. (OFF) mark lights and
Start Stop
Press the (RESERVE) the (ON) mark blinks.
button.
● The device will turn on (off) and off PM
(on) at the designated times.
● The switching occurs first at the PM PM
preset time that comes earlier.
● The arrow mark appearing on the
display indicates the sequence of
switching operations. AM
NOTE
You can set only one of the OFF-timer,
ON-timer and ON/OFF-timer.
– 12 –
ENGLISH
2 Press the 3 Set the current time with the 4 Press the (TIME) button again.
(TIME) button. TIMER control button. The time indication starts lighting
instead of flashing.
2 Set the turn-off time with the 3 Point the signal window of the remote controller toward the indoor unit, and
TIMER control button. press the (RESERVE) button.
The (OFF) mark starts lighting instead of flashing and the sign (RESERVED)
PM lights. A beep occurs and the (TIMER) lamp lights on the indoor unit.
PM
Example: The device will turn off at 11:00p.m.
2 Set the turn-on time with the 3 Point the signal window of the remote controller toward the indoor unit, and
TIMER control button. press the (RESERVE) button.
The (ON) mark starts lighting instead of flashing and the (RESERVED) sign
lights. A beep occurs and the (TIMER) lamp lights on the indoor unit.
Example:
AM
AM
The device will turn on at 7:00 a.m.
The setting of the turn-on time is now complete.
4 Set the turn-on time with the 5 Point the signal window of the remote controller toward the indoor unit, and
TIMER control button. press the (RESERVE) button.
The (ON) mark starts lighting instead of flashing and the (RESERVED) sign
lights. A beep occurs and the (TIMER) lamp lights on the indoor unit.
PM
PM Example:
The device will turn off at 10:30 p.m. and it will be turn on
at 7:00 a.m.
The settings of the turn-on/off times are now complete.
AM
AM
● The timer may be used in three ways: off-timer, on-timer, and ON/OFF (OFF/ON)-timer. Set
the current time at first because it serves as a reference.
● As the time settings are stored in memory in the remote controller, you only have to press
the (RESERVE) button in order to use the same settings next time.
– 13 –
HOW TO SET THE SLEEP TIMER
Set the current time at first if it is not set before (see the pages for setting
the current time). Press the (SLEEP) button, and the display changes as
shown below.
Mode Indication
41 hour 42 hours 4 3 hours 47 hours
H Sleep timer
Sleep timer off 1
Sleep Timer: The device will continue working for the designated
number of hours and then turn off.
SLEEP Point the signal window of the remote controller toward the indoor
unit, and press the SLEEP button.
The timer information will be displayed on the remote controller.
The TIMER lamp lights with a beep from the indoor unit. When the
sleep timer has been set, the display indicates the turn-off time.
Example: If you set 3 hours sleep
time at 11:38 p.m., the turn-off
H time is 2:38 a.m.
NOTE
● If date or current time is not set, sleep timer can not be set.
● If you set the sleep timer after the off-, on/off- or off/on-timer has been set, the sleep timer becomes
effective instead of the off-, on/off- or off/on-timer set earlier.
● You can not set other timer during sleep timer operation.
● After sleep timer time is up and when press sleep button again, the sleep timer will be set as last setting.
● Sleep timer effective only once.
– 14 –
ADJUSTING THE AIR DEFLECTOR
ENGLISH
1 Adjustment of the conditioned air in the upward and downward
directions.
The horizontal air deflector is automatically set to the proper
angle suitable for each operation. The deflector can be swung RESET
When cooling
dehumidifying
Hold the vertical air deflector as shown in the figure and adjust
the conditioned air to the left and right.
– 15 –
HOW TO EXCHANGE THE BATTERIES IN THE REMOTE CONTROLLER
1 Remove the cover as shown in the figure and take out the
old batteries.
Push and pull to the
direction of arrow
=
2 Install the new batteries.
The direction of the batteries should match the marks in the
case.
! CAUTION
1. Do not use new and old batteries, or different kinds of batteries
together.
2. Take out the batteries when you do not use the remote controller
for 2 or 3 months.
– 16 –
THE IDEAL WAYS OF OPERATION
ENGLISH
Suitable Room Temperature Install curtain or blinds
! Warning It is possible to
Freezing temperature reduce heat
is bad for health and a entering the
waste of electric power. room through
windows.
Do Not Forget To Clean The Air Filter Please Adjust Suitable Temperature
Dusty air filter will reduce the air volume and For Baby And Children
the cooling efficiency. To prevent from wasting
Please pay attention to the room temperature
electric energy, please clean the filter every 2
and air flow direction when operating the unit
weeks.
for baby, children and old folks who have
difficulty in movement.
– 17 –
FOR USER’S INFORMATION
! Caution
If the amount of heat in the room is above the cooling
capability of the air conditioner (for example: more
people entering the room, using heating equipments
and etc.), the preset room temperature cannot be
achieved.
! Warning
To protect the whole unit during lightning, please
stop operating the unit and remove the plug from the
socket.
UV-LED
UV-LED will be “ON” when the START/STOP button is pressed. Light UV glare is visible when the UV-
LED is “ON” and this is normal (not malfunction).
! Caution Inverter-type
fluorescent
To avoid noise interference, please place the indoor lamp.
– 18 –
ATTACHING THE AIR CLEANSING AND DEODORIZING FILTERS
ENGLISH
! CAUTION
Cleaning and maintenance must be carried out only by qualified service personal. Before cleaning,
stop operation and switch off the power supply.
! CAUTION
Do not bend the Nano Titanium
filter as it may cause damage to
the structure.
NOTE
● In case of removing the Nano Titanium filters, please follow the above procedures.
● The cooling capacity is slightly weakened and the cooling speed becomes slower when the Nano
Titanium filters are used. So, set the fan speed to "HIGH" when using it in this condition.
● Nano Titanium filters are not washable and can be use in 1 year time. Type number for this air
cleansing filter is <SPX-CFH14>. Please use this number for ordering when you want to renew it.
● Do not operate the air conditioner without filter. Dust may enter the air conditioner and fault may occur.
– 19 –
MAINTENANCE
! CAUTION
Cleaning and maintenance must be carried out only by qualified service personal. Before cleaning,
stop operation and switch off the power supply.
1. AIR FILTER
Clean the air filter, as it removes dust inside the room. In case the air filter is full of dust, the air flow
will decrease and the cooling capacity will be reduced. Further, noise may occur. Be sure to clean the
filter following the procedure below.
PROCEDURE
NOTE:
● Nano Titanium filter should be cleaned every month or sooner if noticeable loading occurs. When
used overtime, it may loose its deodorizing function. For maximum performance, it is recommended
to replace it every 1 year depending on application requirements.
! CAUTION
● Do not wash with hot water at more than 40°C. The filter may shrink.
● When washing it, shake off moisture completely and dry it in the shade; do not expose it directly to
the sun. The filter may shrink.
● Do not use detergent on the Nano Titanium filter as some detergent may deteriorate the filter
electrostatic performance.
– 20 –
ENGLISH
2. Washable Front Panel
Arm Projection
Hole
Flange
● When the front panel is fully opened with ● Move the projections of the left and right
both hands, push the right arm to the inside arms into the Flanges in the unit and
to release it, and while closing the front panel securely insert them into the holes.
slightly, put it out forward.
! CAUTION
● Do not splash or direct water to the body of the unit when cleaning
it as this may cause short circuit.
● Never use hot water (above 40°C), benzine, gasoline, acid, thinner or
a brush, because they will damage the plastic surface and the coating.
– 21 –
! CAUTION
Cleaning and maintenance must be carried out only by qualified service personal. Before cleaning,
stop operation and switch off the power supply.
REGULAR INSPECTION
– 22 –
AFTER SALE SERVICE AND WARRANTY
ENGLISH
WHEN ASKING FOR SERVICE, CHECK THE FOLLOWING POINTS.
Notes
● In quiet operation or stopping the operation, the following phenomena
may occassionally occur, but they are not abnormal for the operation.
(1) Slight flowing noise of refrigerant in the refrigerating cycle.
(2) Slight rubbing noise from the fan casing which is cooled and then
gradually warmed as operation stops.
● The odor will possibly be emitted from the room air conditioner because
the various odor, emitted by smoke, foodstuffs, cosmetics and so on,
sticks to it. So the air filter and the evaporator regularly must be cleaned
to reduce the odor.
● Please contact your sales agent immediately if the air conditioner still fails to operate normally after the above
inspections. Inform your agent of the model of your unit, production number, date of installation. Please also
inform him regarding the fault.
● Power supply shall be connected at the rated voltage, otherwise the unit will be broken or could not reach the
specified capacity.
Please note:
On switching on the equipment, particularly when the room light is dimmed, a slight brightness fluctuation
may occur. This is of no consequence.
The conditions of the local Power Supply Companies are to be observed.
Note
● Avoid to use the room air conditioner for cooling operation when the outside temperature is below
21°C (70°F).
The recommended maximum and minimum operating temperatures of the hot and cold sides
should be as below:
Cooling Heating
Minimum Maximum Minimum Maximum
Dry bulb °C 21 32 20 27
Indoor
Wet bulb °C 15 23 12 19
Dry bulb °C 21 43 2 21
Outdoor
Wet bulb °C 15 26 1 15
– 23 –