t40.1001 JUMO MIDAS OEM Pressure Transmitter

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

-802*PE+

&R.* -802,QVWUXPHQW&R/WG -8023URFHVV&RQWURO,QF


'HOLYHU\DGGUHVV 0DFNHQURGWVWUD‰H -802+RXVH 0\HUV5RDG
)XOGD*HUPDQ\ 7HPSOH%DQN5LYHUZD\ (DVW6\UDFXVH1<86$
3RVWDODGGUHVV )XOGD*HUPDQ\ +DUORZ(VVH[&0'<8. 3KRQH 
3KRQH  3KRQH  )D[ 
)D[  )D[  (PDLO LQIRXV#MXPRQHW
(PDLO PDLO#MXPRQHW (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRXVDFRP
,QWHUQHW ZZZMXPRQHW ,QWHUQHW ZZZMXPRFRXN

Data Sheet 401001 Page 1/8

JUMO MIDAS
OEM-Pressure Transmitter

Applications
• Compressors
• Mechanical and plant engineering
• Industrial Pneumatics
• Commercial vehicles
• Building technology

Brief description
The pressure transmitter is used for pressure measurement of liquid and gaseous media. With
the well proofed ceramic thick film sensor, the pressure is measured, converted into an electrical
standard signal (voltage or current) and output via electrical connections, e.g. cable socket, M12
plug or attached cable.
A large number of process connections are available for adaptation to the process.
Type 401001 with cable socket

Type 401001 with round plug M12

Customer benefits Special features


• Process-reliable • From 0 to 1,6 bar up to 0 to 100 bar,
The ceramic measuring cell made of alumina exhibits good long-term stability, achieved relative pressure
through selected sensor material and a special adjustment procedure, as well as high over- • Elastomer-sealed
load resistance. The high quality of each pressure transmitter is ensured by the 100 % final • Compact design: from 58 mm length
inspection of a fully automated measuring and calibration system.
• High chemical resistance
• Economic
• High mechanical strength membrane
A largely automated production process (digital compensation and calibration of the sensor
assembly) reduces production time and manufacturing costs - an optimal price-performance
ratio is achieved.
• Versatile
A wide range of measuring ranges, process connections and electrical connections as well
as all standard signals are available. Thus an optimal adaptation to the measuring task is
possible.
• Proven
The instrument is the basis of the proven pressure transmitter series JUMO MIDAS. More
than 1 million devices in various applications and applications in the field speak for them-
selves.

V3.00/EN/00398114/2020-03-10 40100100T10Z001K000
-802*PE+ &R.* -802,QVWUXPHQW&R/WG -8023URFHVV&RQWURO,QF
'HOLYHU\DGGUHVV 0DFNHQURGWVWUD‰H -802+RXVH 0\HUV5RDG
)XOGD*HUPDQ\ 7HPSOH%DQN5LYHUZD\ (DVW6\UDFXVH1<86$
3RVWDODGGUHVV )XOGD*HUPDQ\ +DUORZ(VVH[&0'<8. 3KRQH 
3KRQH  3KRQH  )D[ 
)D[  )D[  (PDLO LQIRXV#MXPRQHW
(PDLO PDLO#MXPRQHW (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRXVDFRP
,QWHUQHW ZZZMXPRQHW ,QWHUQHW ZZZMXPRFRXN

Data Sheet 401001 Page 2/8

Technical data
General Information
Reference conditions To DIN 16086 and DIN EN 60770
Mounting position Any
Calibration position Device upright, process connection at the bottom

Measuring range and accuracy


Measuring range Linearitya Accuracy at Long term Overloadc Burst
20 °C d
-20 to +100 °C e stabilityb
bar % MSPf % MSP % MSP % MSP bar bar
per year
0 to 1.6 bar relative pressure 0.3 0.5 1.6 ≤ 0.2 6 12
0 to 2.5 bar relative pressure 0.3 0.5 1.6 6 12
0 to 4 bar relative pressure 0.3 0.5 1.6 12 25
0 to 6 bar relative pressure 0.25 0.5 1.4 12 25
0 to 10 bar relative pressure 0.25 0.5 1.4 20 38
0 to 16 bar relative pressure 0.25 0.5 1.4 50 75
0 to 25 bar relative pressure 0.25 0.5 1.4 50 75
0 to 40 bar relative pressure 0.25 0.5 1.4 120 200
0 to 60 bar relative pressure 0.25 0.5 1.4 120 200
0 to 100 bar relative pressure 0.25 0.5 1.4 180 250
-1 to +0.6 bar relative pressure 0.3 0.6 1.6 6 12
-1 to +1.5 bar relative pressure 0.3 0.6 1.6 6 12
-1 to +3 bar relative pressure 0.3 0.6 1.6 12 25
-1 to +5 bar relative pressure 0.25 0.6 1.4 12 25
-1 to +9 bar relative pressure 0.25 0.6 1.4 20 38
-1 to +15 bar relative pressure 0.25 0.6 1.4 50 75
-1 to +24 bar relative pressure 0.25 0.6 1.4 50 75
a
Linearity according to limit point-setting, DIN EN 61298-2
b Reference conditions DIN EN 61298-1
c All pressure transmitter are vaccum proof.
d
Includes: linearity, hysteresis, repeatability, deviation from measuring range start (offset), and measuring range end
e
Includes: linearity, hysteresis, repeatability, deviation from measuring range start (offset) and measuring range end, thermal influences on mea-
suring range start (offset), and measuring span
f
MSP = measuring span

V3.00/EN/00398114/2020-03-10 40100100T10Z001K000
-802*PE+ &R.* -802,QVWUXPHQW&R/WG -8023URFHVV&RQWURO,QF
'HOLYHU\DGGUHVV 0DFNHQURGWVWUD‰H -802+RXVH 0\HUV5RDG
)XOGD*HUPDQ\ 7HPSOH%DQN5LYHUZD\ (DVW6\UDFXVH1<86$
3RVWDODGGUHVV )XOGD*HUPDQ\ +DUORZ(VVH[&0'<8. 3KRQH 
3KRQH  3KRQH  )D[ 
)D[  )D[  (PDLO LQIRXV#MXPRQHW
(PDLO PDLO#MXPRQHW (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRXVDFRP
,QWHUQHW ZZZMXPRQHW ,QWHUQHW ZZZMXPRFRXN

Data Sheet 401001 Page 3/8

Electrical data
Output signala 4 to 20 mA, two-wire DC 0.5 to 4.5 V, three-wire, DC 0 to 10 V, three-wire
(output 405) ratiometricb (output 415)
(output 412)
Burden or loadc RB ≤ (UB - 10 V) ÷ 0.02 A RL ≥ 20 kΩ RL ≥ 10 kΩ
Output current 3.6 to 22 mA -20 to +250 µA -20 µA to +1 mA
Voltage supply UBd DC 10 to 30 V DC 4.75 to 5.25 V DC 11.5 to 30 V
Nominal voltage DC 24 V DC 5 V DC 24 V
Voltage supply influence ≤ 0.02 %/V ≤ 0.02 %/V ≤ 0.02 %/V
Current consumptione ≤ 25 mA ≤ 5 mA ≤ 5 mA
Reverse voltage protection Yes No Yes
Short-circuit resistancef - No Yes
Step response T90 ≤ 3 ms ≤ 3 ms ≤ 3 ms

Output signala DC 1 to 5 V, three-wire DC 1 to 6 V, three-wire DC 0 to 10 V, three-wire,


(output 418) (output 420) increased driver power
(output 422)
Burden or loadc RL ≥ 10 kΩ RL ≥ 10 kΩ RL ≥ 2 kΩ
Output current -20 µA to +1 mA -20 µA to +1 mA -200 µA to +5 mA
Voltage supply UBd DC 8 to 30 V DC 8 to 30 V DC 11.5 to 30 V
Nominal voltage DC 24 V DC 24 V DC 24 V
Voltage supply influence ≤ 0.02 %/V ≤ 0.02 %/V ≤ 0.02 %/V
Current consumptione ≤ 5 mA ≤ 5 mA ≤ 5 mA
Reverse voltage protection Yes Yes Yes
Short-circuit resistancef Yes Yes Yes
Step response T90 ≤ 3 ms ≤ 3 ms ≤ 3 ms
a
Further outputs are available upon request.
b
Ratiometric output: output signal from 10 to 90 % of the voltage supply
c
Load resistance to S-
d
Residual ripple: The voltage peaks or dips must not exceed or fall below the specified voltage supply values! The device must be equipped with
an electrical circuit that meets the requirements of EN 61010-1 with regard to "Limited-energy circuits".
e
For no-load operation (output unloaded)
f
Short-circuit resistance S+ against V-

V3.00/EN/00398114/2020-03-10 40100100T10Z001K000
-802*PE+ &R.* -802,QVWUXPHQW&R/WG -8023URFHVV&RQWURO,QF
'HOLYHU\DGGUHVV 0DFNHQURGWVWUD‰H -802+RXVH 0\HUV5RDG
)XOGD*HUPDQ\ 7HPSOH%DQN5LYHUZD\ (DVW6\UDFXVH1<86$
3RVWDODGGUHVV )XOGD*HUPDQ\ +DUORZ(VVH[&0'<8. 3KRQH 
3KRQH  3KRQH  )D[ 
)D[  )D[  (PDLO LQIRXV#MXPRQHW
(PDLO PDLO#MXPRQHW (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRXVDFRP
,QWHUQHW ZZZMXPRQHW ,QWHUQHW ZZZMXPRFRXN

Data Sheet 401001 Page 4/8

Mechanical features
Material
Process connection Stainless steel 305
Internala at seal 601 FPM, standard
Internala at seal 602 CR
Internala at seal 604 FFPM
Internala at seal 999 Special material
Externala at G 1/4 FPM
(process connection 521)
Sensor Ceramic Al2O3 96 %,
Measuring principle: Thick film on ceramic body (piezoresistive)
Housing Stainless steel 305
Attached cable PBT-GF30, PVC
(electrical connection 11)
Round plug M12 × 1 PBT-GF30, stainless steel 303 L
(electrical connection 36)
Cable socket PBT-GF30, PA, silicone
(electrical connection 61)
Sensor
Admissible load change > 10 million, 0 to 100 % measuring range
Weight 100 g with G 1/4 (process connection 502)
a
Note the medium durability of the selected seal material!

Environmental influences
Admissible temperatures
for electrical connection
Medium -20 to +125 °C
Ambient -20 to +85 °C
Storage -40 to +125 °C (for version with attached cable [electrical connection 11] -20 to +100 °C)
Admissible air humidity
Operation 100 % relative humidity including condensation on the device outer case
Storage 90 % elative humidity without condensation
Admissible mechanical load
Vibration resistancea 20 g for 10 to 2000 Hz
Shock resistanceb 100 g for 1 ms
Electromagnetic compatibilityc
Interference emission Class Bd
Interference immunity Industrial requirements
Protection type
for electrical connectione
Attached cable IP67
Round plug M12 × 1f IP67
Leitungsdosef, g IP65
a IEC 60068-2-6
b
IEC 60068-2-27
c DIN EN 61326-1 and DIN EN 61326-2-3
d
The product is suitable for industrial use as well as for households and small businesses.
e
DIN EN 60529
f
The protection type is only achieved with a suitable mounted counter piece.
g
Connecting cable diameter, minimum 5mm, maximum 8 mm

V3.00/EN/00398114/2020-03-10 40100100T10Z001K000
-802*PE+ &R.* -802,QVWUXPHQW&R/WG -8023URFHVV&RQWURO,QF
'HOLYHU\DGGUHVV 0DFNHQURGWVWUD‰H -802+RXVH 0\HUV5RDG
)XOGD*HUPDQ\ 7HPSOH%DQN5LYHUZD\ (DVW6\UDFXVH1<86$
3RVWDODGGUHVV )XOGD*HUPDQ\ +DUORZ(VVH[&0'<8. 3KRQH 
3KRQH  3KRQH  )D[ 
)D[  )D[  (PDLO LQIRXV#MXPRQHW
(PDLO PDLO#MXPRQHW (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRXVDFRP
,QWHUQHW ZZZMXPRQHW ,QWHUQHW ZZZMXPRFRXN

Data Sheet 401001 Page 5/8

Dimensions
Electrical connection
11 36 61
Attached cable Round plug M12 × 1 Cable socket
M12 × 1 35

16

29
36
43

27
Pg 9

63
Ø 27
27 27

G 1/4

Process connection
501 502 511
G 1/8 G 1/4 1/4-18 NPT

521 523 562


G 1/4 G 1/2 7/16-20 UNF external

A Profile seal G 1/4 B Profile seal G 1/2

V3.00/EN/00398114/2020-03-10 40100100T10Z001K000
-802*PE+ &R.* -802,QVWUXPHQW&R/WG -8023URFHVV&RQWURO,QF
'HOLYHU\DGGUHVV 0DFNHQURGWVWUD‰H -802+RXVH 0\HUV5RDG
)XOGD*HUPDQ\ 7HPSOH%DQN5LYHUZD\ (DVW6\UDFXVH1<86$
3RVWDODGGUHVV )XOGD*HUPDQ\ +DUORZ(VVH[&0'<8. 3KRQH 
3KRQH  3KRQH  )D[ 
)D[  )D[  (PDLO LQIRXV#MXPRQHW
(PDLO PDLO#MXPRQHW (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRXVDFRP
,QWHUQHW ZZZMXPRQHW ,QWHUQHW ZZZMXPRFRXN

Data Sheet 401001 Page 6/8

Connection diagram
The connection diagram in the data sheet provides preliminary information about the connection options. For the electrical connection, only use
the installation instructions or the operating manual. The knowledge and the correct technical compliance with the safety information and warnings
contained in these documents are mandatory for mounting, electrical connection, and startup as well as for safety during operation.

Connction Terminal assignmenta


2
1

3
3 1
2
4

11 36 61
Attached cable Round plug Cable socket
M12 × 1
4 to 20 mA, two-wire (output 405)
Voltage supply DC 10 to 30 V UB/S+ WH 1 1
0 V/S- BN 3 2
DC 0.5 to 4.5 V, three-wire, ratiometric (output 412)
Voltage supply DC 4.75 to 5.25 Vb UB WH 1 1
0 V/S- BN 2 2
S+ YE 3 3
DC 0 to 10 V, three-wire (output 415)
Voltage supply DC 11.5 to 30 V UB WH 1 1
0 V/S- BN 2 2
S+ YE 3 3
DC 1 to 5(6) V, three-wire (output 418 [420])
Voltage supply DC 8 to 30 V UB WH 1 1
0 V/S- BN 2 2
S+ YE 3 3
Functional bonding conductor FBc - 4

a
Figure: Connection to the pressure transmitter
b
The device must be equipped with an electrical circuit that meets the requirements of EN 61010-1 with regard to "Limited-energy circuits".
c
The pressure transmitter has to be connected to the potential equalization system of the plant via the electrical connection or process connec-
tion.

Color coding: connecting cable round plug M12 × 1 1 BN Brown


2 WH White
3 BU Blue
4 BK Black
The color coding is only valid for A-coded standard cables!

V3.00/EN/00398114/2020-03-10 40100100T10Z001K000
-802*PE+ &R.* -802,QVWUXPHQW&R/WG -8023URFHVV&RQWURO,QF
'HOLYHU\DGGUHVV 0DFNHQURGWVWUD‰H -802+RXVH 0\HUV5RDG
)XOGD*HUPDQ\ 7HPSOH%DQN5LYHUZD\ (DVW6\UDFXVH1<86$
3RVWDODGGUHVV )XOGD*HUPDQ\ +DUORZ(VVH[&0'<8. 3KRQH 
3KRQH  3KRQH  )D[ 
)D[  )D[  (PDLO LQIRXV#MXPRQHW
(PDLO PDLO#MXPRQHW (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRXVDFRP
,QWHUQHW ZZZMXPRQHW ,QWHUQHW ZZZMXPRFRXN

Data Sheet 401001 Page 7/8

Order details
(1) Basic type
401001/000 JUMO MIDAS SI – OEM-Pressure transmitter
401001/999 JUMO MIDAS SI – OEM-Pressure transmitter, special version
(2) Input
455 0 to 1,6 bar relative pressure
456 0 to 2.5 bar relative pressure
457 0 to 4 bar relative pressure
458 0 to 6 bar relative pressure
459 0 to 10 bar relative pressure
460 0 to 16 bar relative pressure
461 0 to 25 bar relative pressure
462 0 to 40 bar relative pressure
463 0 to 60 bar relative pressure
464 0 to 100 bar relative pressure
479 -1 to +0.6 bar relative pressure
480 -1 to +1,5 bar relative pressure
481 -1 to +3 bar relative pressure
482 -1 to +5 bar relative pressure
483 -1 to +9 bar relative pressure
484 -1 to +15 bar relative pressure
485 -1 to +24 bar relative pressure
999 Special measuring range relative pressure
(3) Output
405 4 to 20 mA, two-wire
412 0.5 to 4.5 V, three-wire
415 0 to 10 V, three-wire
418 1 to 5 V, three-wire
420 1 to 6 V, three-wire
422 0 to 10 V, three-wire, for increased driving power
(4) Process connection
501 G 1/8 according to DIN EN 837
502 G 1/4 according to DIN EN 837
511 1/4-18 NPT according to DIN EN 837
521 G 1/4 according to DIN 3852-11
523 G 1/2 according to DIN 3852-11
562 7/16-20 UNF external
(5) Process connection material
20 CrNi (stainless steel)
(6) Seal
601 FPM
602 CR
604 FFPM
999 Special material
(7) Electrical connection
11 Attached cablea
36 Round plug M12 × 1
61 Cable socket DIN EN 175301-803, form A

V3.00/EN/00398114/2020-03-10 40100100T10Z001K000
-802*PE+ &R.* -802,QVWUXPHQW&R/WG -8023URFHVV&RQWURO,QF
'HOLYHU\DGGUHVV 0DFNHQURGWVWUD‰H -802+RXVH 0\HUV5RDG
)XOGD*HUPDQ\ 7HPSOH%DQN5LYHUZD\ (DVW6\UDFXVH1<86$
3RVWDODGGUHVV )XOGD*HUPDQ\ +DUORZ(VVH[&0'<8. 3KRQH 
3KRQH  3KRQH  )D[ 
)D[  )D[  (PDLO LQIRXV#MXPRQHW
(PDLO PDLO#MXPRQHW (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRXVDFRP
,QWHUQHW ZZZMXPRQHW ,QWHUQHW ZZZMXPRFRXN

Data Sheet 401001 Page 8/8

(8) Extra code


000 None
591 Choke in the pressure channel
624 Oil and grease free
a The standard cable length is 2 m. Further lengths are available upon request.

(1) (2) (3) (4) (5) (6) (7) (8)


Order code - - - - - - / , ...a
Order example 401001/000 - 460 - 412 - 502 - 20 - 601 - 36 / 591
a List extra codes in sequence, separated by commas.

Accessories
Item Part no.
Cable socket, straight, 4-pin, M12 × 1. 2 m 00404585
Cable socket, angled, 4-pin, M12 × 1. 2 m 00409334
M12 connector, 4-pin, with connecting cable, 5 m 00512341

V3.00/EN/00398114/2020-03-10 40100100T10Z001K000

You might also like