Operating Instructions SZ-7556-58-66-68-P: General Description Installation and Dimensions
Operating Instructions SZ-7556-58-66-68-P: General Description Installation and Dimensions
Operating Instructions SZ-7556-58-66-68-P: General Description Installation and Dimensions
SZ-7556-58-66-68-P
General Description Installation and Dimensions
70.5
34.5
a contactor esp. in single phase applications.
The controllers have special features like power on time delay for
alarms. Additionally these series offer several protection features that
are easily understood by the examples in the instructions below.
A number of parameters are displayed alphanumerically to set up the
instrument for each specific application.
To fix the unit, slide the fastener 1 through the guides 2 as per the position shown in
SZ-7556/58-P can be used for several applications with a measuring the figure. Move the fastener in the direction of the arrow, pressing tab 3 it permits to
range from 0OC to + 50OC, whereas SZ-7566-68-P can be used for move the fastener in the opposite direction of the arrow. Once the controller has been
connected, they should be covered with the lid 4 . Silicon sealant should be applied
several applications with a measuring range from -50OC to + 99OC. along the perimeter of the panel cut out or a rubber ‘O’ ring supplied before the unit is
fitted to increase protection against water seepage.
Controller: Controller should be installed in a place protected by vibration, water and
Technical Data corrosive gasses and where ambient temperature does not exceed the values specified
in the technical data.
Probe: To give a correct reading, the probe must be installed in a place protected from
Housing Black, ABS Plastic thermal influences, which may affect the temperature to be controlled.
Front Cover Red Polycarbonate plastic.
Dimensions Front : 75 X 34.5 MM Operating Messages And Icon Status
Depth : 71 MM (w/o back lid)
Panel Cutout 29 X 70.5 MM Message Mode Description Parameter
Mounting Flush panel mounting with fasteners.
H Flashing Temp. above the maximum limit of the set point. P2
Frontal protection IP 65 Flashing Temp. below the minimum limit of the set point. P3
Connections Screw terminal blocks. 2.5 sq mm one wire/ terminal Flashing Probe short circuit, circuit open or without probe,
only. or temperature>70OC or <0OC for SZ-7556/58-P
or temperature>99OC or <-50OC for
Display 2 X14.2 mm (0.56") LED. SZ-7566/68-P.
Data storage Non-volatile EEPROM memory. ON/OFF Comp. Relay on/off. SP, P4
Power input 230Vac +/-10%,50-60Hz. Others on request. Flashing Comp. Relay time delay active. P6
Operating temp. 5OC to 50OC (non-condensing).
ON/OFF Alarm Relay On/Off. AL,P7
Storage temp -20OC to 70OC (non-condensing).
ON/OFF Keypad locked/unlocked. LP
Input NTC Probe, SZ-N75
Resolution 1OC
Accuracy +/- 1OC Min = Minimum, Max = Maximum
Probe tolerance +/- 0.3O C at 25O C Fac. = Factory Setting (Default)
1. Set Point : To set the cut out point. Min Max Fac.
Front Panel View, Relay O
0C 50 C
O O
0C
1. Press and hold the “SET” key for 2 Seconds.
SZ-7556 /58-P
2. The set value will start flashing.
3. Use or prg to set the desired range. -50OC 99OC 0OC
SZ-7566 /68-P
4. Press key & you will see “- - -” which confirms
that the set point has been stored in memory.
7. P5 Parameter : To set probe calibration. This key will reset the alarm relay.
Min Max Fac.
In time it may be possible that the display may be -9OC 10OC 0OC 12. E I Parameter : To set relay status on Probe Failure.
Min Max Fac.
offset by a degree or so. To compensate for this error, SZ-7556 /58-P
you may need to add or minus the degrees required to
1. To change the E1 parameter, press the “SET” key. 0 2 1
achieve the correct temperature. -10OC 10OC 0OC
2. To go to desired value, use or keys.
SZ-7566 /68-P
1. To change the P5 parameter, press the “SET” key.
2. To go to desired value, use or keys. 0 : Comp.relay status is ON.
3. To set confirm value press “SET” key you will see I : Comp. Relay performs a duty cycle 10
“- - -” which confirms that the value has been stored minutes ON and 4 minutes OFF.
in memory. 2 : Relay status is OFF.
Example: The temperature on the display is 28OC, 3. To set confirm value press “SET” key you will see
“- - -” which confirms that the value has been stored
whereas the actual temperature is 30OC. You will need
in memory.
to set the P5 mode to 2, which means that once out of
the programming mode, the temperature will show
30OC (28OC + 2OC). 13. FS Parameter : To restore default settings of the controller.
Min Max Fac.
8. P6 Parameter : To set time delay between relay restart time.
Min Max Fac. When set to 1 all parameters are programmed to 0 1 0
factory values. Useful to debug setting related
This parameter is used to protect the compressor from 0 Min 99 Min 3 Min problems.
restarting in a short period of time and can be set
between 0 to 99 minutes. 1. To change the FS parameter, press the “SET” key.
2. To go to desired value, use or keys.
1. To change the P6 parameter, press the “SET” key. 3. To set confirm value press “SET” key you will see
2. To go to desired value, use or keys. “- - -” which confirms that the value has been stored
3. To set confirm value press “SET” key you will see Flashing in memory.
(Time delay in progress)
“- - -” which confirms that the value has been stored
in memory. 14. EP Parameter : To end programming.
Example: If this parameter is set at 3 minutes, the
relay will cut off at the set temperature, but will not Once the SET key is pressed, the control goes into the
restart for a minimum of 3 minutes, even if the normal mode and displays the temperature and all
differential is achieved earlier. This parameter is good settings are recorded.
Compressor /Heater or
Contactor 8(3)A max
NOTICE: The information in this document is subject to change in order to
Alarm 5A max
To SZ-N75 improve reliability , design or function without prior notice and does not
represent a commitment on the part of the company. In no event will the
company be liable for direct, indirect, special, incidental or consequential
damage arising out of the use or inability to use the product or documentation,
even if advised of the possibility of such damages. No part of this manual may
be reproduced or transmitted in any form or by any means without the prior
written permission of the company.
DISCLAIMER: This manual & its contents remain the sole property of
ACR Instruments & Valves Pvt. Ltd.,H.P., India and shall not be reproduced or
distributed without authorization. Although great care has been taken in the
preparation of this document, the company or its vendors in no event will be
liable for direct, indirect, special, incidental or consequential damage arising
out of the use or inability to use the product or documentation, even if advised
SZ-7558/68-P of the possibility of such damages. No part of this manual may be reproduced
or transmitted in any form or by any means without the prior written permission
of the company. ACR Instruments & Valves Pvt. Ltd.,H.P., reserves the right to
make and changes or improvements without prior notice.
ALARM 230V
COMPRESSOR C NO
WARRANTY: This product is warranted against defects in materials and
C NO 7 8 9 10 11 12 workmanship for a period of one year from the date of purchase. During the
PROBE warranty period, product determined by us to be defective in form or function
will be repaired or, at our option, replaced at no charge. This warranty does not
apply if the product has been damaged by accident, abuse, and misuse or as a
result of service or modification other than by the company. This warranty is in
To lieu of any other warranty expressed or implied. In no event shall the company
be held liable for incidental or consequential damages, including lost revenue
Compressor To SZ-N75
Alarm 5A max