Process Specification Heat Exchanger Cpecc

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 2

Client: KUWAIT OIL CO.

PROCESS SPECIFICATION
Site: WEST KUWAIT HEAT EXCHANGER
Unit: GC28
DOCUMENT No. : GC28 -SPP -E - 1505 Rev. 3 Page 1 of 8 CPECC
ITEM NO.: 28-E-1505 / 2505 TYPE: AKU TEMA CLASS R
SERVICE: HP COMPRESS0R TRIM COOLER (AVERAGE CASE) (1)
[1] DUTY /UNIT: 1.713 MMkCal/hr ( 6.797 MMBTU/hr)
OPERATION: SUMMER CASE WITHOUT GAS BACK FLOW (1) NO. OF UNITS: TWO
FLUID : SHELL SIDE: REFRIGERANT ( 3 ) TUBE SIDE: WET GAS ( 4 )
SHELL SIDE TUBE SIDE
[1 TOTAL FLOW RATE /UNIT kg/hr (lb/hr) 24084(53105) 90083(198633)
<STREAM No.> INLET<r11> OUTLET<r12> INLET<52> OUTLET<53>
VAPOR HC (2) kg/hr (lb/hr) 2716(5989) 23802(52483) 82585(182100) 63151(139248)
H20 kg/hr (lb/hr) 178(392) 63(139)
D A T A

NONCONDENSABLES kg/hr (lb/hr)

LIQUID HC kg/hr (lb/hr) 21368(47116) 282(622) 7042(15528) 26478(58384)


H20 kg/hr (lb/hr) 278(613) 391(862)
S S

OPERATING TEMPERATURE o
C (oF) 35.3(95.5) 36(96.8) 57.8(136) 40(107)
1] OPERATING PRESSURE kg/cm2 g (psig) 2.97(42.23) 2.97(42.23) 68.26(970.66) 67.75(963.41)
P R O C E

DESIGN TEMPERATURE o
C (oF) 100 ( 212 ) 180 ( 356 )
DESIGN PRESSURE kg/cm2 g (psig) 13.3 (188.6 ) 76.5 (1087.8 )
ALLOWABLE PRESSURE DROP kg/cm2 (psi) NEGLIGIBLE 0.51 (7.25 )
VACUUM RATING kg/cm2 a (psia)
FOULING FACTOR m2.hr.0C/kCal(ft2.hr.0F/BTU) 0.00023 (0.00114 ) 0.00023 ( 0.00114 )
FLEXIBILITY % 10 TO 115 10 TO 115
INLET OUTLET INLET OUTLET
LIQUID
[1 SPECIFIC GRAVITY 60/60 0.5747 0.5761 0.5273 0.4913
I C S

SPECIFIC GRAVITY AT OPER. TEMP. 0.5501 0.5507 0.4162 0.4256


VISCOSITY AT OPER. TEMP. cP (cP) 0.1504(0.1504) 0.1493(0.1493) 0.0784(0.0784) 0.0762(0.0762)
SPECIFIC HEAT kCal/kg.oC (BTU/lb.oF) 0.5985(0.5985) 0.5997(0.5997) 0.7899(0.7899) 0.7632(0.7632)
I S T

THERMAL COND. kCal/m.hr. oC(BTU/ft.hr.oF) 0.0743(0.0499) 0.0746(0.0501) 0.0628(0.0422) 0.067(0.045)


ENTHALPY MMkCal/hr (MMBTU/hr) -0.0584(-0.2317) -0.0006(-0.0024) 0.0815(0.3234) 0.330(1.3095)
POUR POINT o
C (oF)
C H A R A C T E R

INLET OUTLET INLET OUTLET


VAPOR
MOLECULAR WEIGHT kg / kgmol(lb /lbmol) 58.12(58.12) 58.12(58.12) 29.29(29.29) 27.16(27.16)
DENSITY AT OPER. TEMP. kg/m3 (lb/ft3) 9.8654(0.6156) 9.8131(0.6123) 105.85(6.605) 102.99(6.427)
VISCOSITY AT OPER. TEMP. cP (cP) 0.0078(0.0078) 0.0078(0.0078) 0.0159(0.0159) 0.0153(0.0153)
SPECIFIC HEAT kCal/kg.oC (BTU/lb.oF) 0.4296(0.4296) 0.4305(0.4305) 0.6776(0.6776) 0.6798(0.6798)
THERMAL COND. kCal/m.hr. oC(BTU/ft.hr.oF) 0.0145(0.0097) 0.0146(0.0098) 0.0322(0.0216) 0.0314(0.0211)
1] ENTHALPY MMkCal/hr (MMBTU/hr) 0.210(0.8333) 1.8649(7.400) 7.1313(28.297) 5.1698(20.5137)
LATENT HEAT MMkCal/hr (MMBTU/hr)

PARTICULAR PROPERTIES OF FLUID


SHELL SIDE:
TUBE SIDE:
CONSTRUCTION MATERIAL: CS + NACE
CONSTRUCTION CODE: ASME SECT VIII,DIV1
SHELL: TUBES: MAX. LENGTH:
MAX. DIAMETER
CORROSION ALLOWANCE: 3mm CORROSION ALLOWANCE: 3mm
MATERIAL: SHELL: CS MATERIAL: TUBES: CS +NACE ( 4 )
SHELL COVER: TUBULAR SHEET: CS +NACE
FLOATING BOTTOM: CHANNEL COVER: CS+NACE
DOUBLE PIPE ALLOWED: NO MULTITUBES ALLOWED:
PROCESS LINES DIAMETER: SHELLD SIDE: INLET: 6" OUTLET: 6"
TUBE SIDE: INLET: 12" OUTLET: 12"
[1] NOTE: 1. TRIM COOLER IS BY PASSED IN WINTER. THE SUMMER CONTROLLING CASE WITH GAS BACK FLOW IS THE
CONSIDERED CASE WHICH IS BASED ON BACK UP CALCULATION OF THE AREA REQUIREMENT.
2. TWO OUTLETS FOR VAPOR.
[3] 3. REFRIGERANT IS ASSUMED TO BE A MIXTURE OF 50% iC 4 AND 50% nC4.
4. SOUR SERVICE (GAS CONTAINS H2S ( MAXI. 5% VOL ), CO2 AND H2O ).
5. A BOOT FOR LUBE OIL DRAINING TO BE PROVIDED.
[1] 6. OPERATING FLOWRATE AND HEAT DUTY ARE AT 97.75% OF THE DATA AS SHOWN.