Power Distribution Units (PDU)

Blade servers and high density computing power requirements


continue to increase, creating heat expansion and more
challenges for managing the IT environment. To maintain a
competitive advantage, data center managers need SNMP–based
solutions that monitor, track and manage servers, IT equipment
and the equipment cabinet infrastructure that houses them. PDU
power distribution units may monitor, track, and manage every
aspect of data center activity and provide efficient solutions for
critical elements including data center cooling, security and
server management. Rittal’s Basic PDU products provide reliable
power distribution for equipment racks and other data center
applications. User-friendly features include a combination of white
and black outlets to easily distinguish between each branch circuit.
Included here are the most popular sizes and configurations.

• 120V and 208V power options


• 20 or 30 amp options on basic units
• UL-list fuses and circuit breakers
• Metered models monitor from 2,000 to 6,000 watt
components
• Smart PDU models combine distribution with remote
monitoring for 4,000 to 20,000 watts
• Smart units available in 20, 30, 50 and 60 amp versions
• Receptacle configurations from 6 to 48 outlets
• PIPS – Per Inlet Power Sensing – units monitor current,
voltage, power and other vital requirements
• POPS – Per Outlet Power Sensing – units provide data on
such things as load, voltage and power (kW)
• Switched PDU models offer complete “lights out” remote
management
• Accessories include temperature and humidity sensors

www.rittal.us
Basic PDU
Basic PDU products provide reliable power distribution for equipment racks and Criteria for Branch Circuit Protection is met by the use of UL-listed fuses or
other data center applications by offering different input and output connections to breakers, with 30 Amp models featuring a combination of white and black outlets to
distribute 110V or 208V power and 20 or 30 Amp power input feed. easily distinguish between each branch circuit.

No. of Over current L xW x H


Voltage Amps Receptacles Plug Part No.
receptacles protection inches (mm)
1.75 x 17 x 2.25
120V 20 5-20 12 C20 – 9970.8431)
(44 x 482 x 57)
31.25 x 1.75 x 2.25
120V 20 5-20 24 C20 – 9970.8471)
(794 x 44 x 57)
1.75 x 17 x 2.25
120V 30 5-20 12 L5-30 – 9970.844
(44 x 482 x 57)
31.25 x 1.75 x 2.25
120V 30 5-20 24 L5-30 – 9970.848
(794 x 44 x 57)
1.75 x 17 x 2.25
208V 20 C13 12 C20 – 9970.8451)
(44 x 482 x 57)
34 x 1.75 x 3.5
208V 20 C13 24 C20 Breaker 9978.4401)
(864 x 44 x 89)
1.75 x 17 x 2.25
208V 30 C13 12 L6-30 – 9970.846
(44 x 482 x 57)
34 x 1.75 x 3.5
208V 30 C13 24 L6-30 Breaker 9978.441
(864 x 44 x 89)
1) Order power cord separatey
Metered PDU
Metered PDU products provide reliable power distribution for all the devices in Metered units are available in 20 or 30 Amps, 120 or 208 Volts single-phase. Local
your equipment cabinet, from 2,000 to 6,000 Watts. input current monitoring allows the installation engineer to verify the combined load
on the circuit.

No. of Over current L xW x H


Voltage Amps Receptacles Plug Part No.
receptacles protection inches (mm)
1.75 x 17 x 5
120V 20 5-20 10 C20 – 9963.6781)
(44 x 432 x 127)
31.25 x 1.75 x 2.25
120V 20 5-20 12 C20 Fuse 9963.6701)
(794 x 44 x 57)
54 x 1.75 x 2.25
120V 20 5-20 24 C20 Fuse 9963.6741)
(1372 x 44 x 57)
1.75 x 17 x 5
120V 30 5-20 10 L5-30 – 9963.679
(44 x 432 x 127)
31.25 x 1.75 x 2.25
120V 30 5-20 12 L5-30 Fuse 9963.671
(794 x 44 x 57)
54 x 1.75 x 2.25
120V 30 5-20 24 L5-30 Fuse 9963.675
(1372 x 44 x 57)
1.75 x 17 x 5
208V 20 C13 12 C20 – 9963.6801)
(44 x 432 x 127)
31.25 x 1.75 x 2.25
208V 20 C13 12 C20 Fuse 9963.6721)
(794 x 44 x 57)
60.0 x 1.75 x 2.25
208V 20 C13, C19 24,6 C20 Breaker 9963.6761)
(1524 x 44 x 57)
1.75 x 17 x 5
208V 30 C13 12 L6-30 – 9963.681
(44 x 432 x 127)
1.75 x 17 x 5
208V 30 C13 24 L6-30 – 9978.444
(44 x 432 x 127)
31.25 x 1.75 x 2.25
208V 30 C13 12 L6-30 Fuse 9963.673
(794 x 44 x 57)
60.0 x 1.75 x 2.25
208V 30 C13, C19 24,6 L6-30 Breaker 9972.960
(1524 x 44 x 57)
1) Order power cord separately
Smart PDU
Smart PDU products provide reliable power distribution combined with remote power and PIPS – Per Inlet Power Sensing – PDUs provide power monitoring per
enviromental monitoring for 4,000 to 20,000 Watts. Smart units are available in 20, 30, 50, or inlet/infeed and includes current, voltage, power, apparent power, crest
60 Amps, 120 or 208 Volts single-phase, 208 Volts three-phase. Use the network interface factor, reactance, power factor and accumulated energy. This information
to view power, temperature and humidity levels via a Web browser, or receive SNMP-based replaces branch circuit monitoring devices typically installed in the power
alarms when conditions exceed defined thresholds. distribution panel or remote power panel (RPP) with higher accuracy and
lower cost monitoring of each circuit attached to the PDU.

No. of Overcurrent L xW x H Master /


Voltage Amps Receptacles Plug Part No.
receptacles protection inches (mm) Expansion
60 x 1.75 x 2.25
208V 20 C13, C19 24, 6 C20 Breaker Master 9978.4461) 2)
(1525 x 44 x 57)
60 x 1.75 x 2.25
208V 20 C13, C19 24, 6 C20 Breaker Expansion 9978.4451) 2)
(1525 x 44 x 57)
1) Order power cord separately 2) Includes PIPS
Smart PDU (continued)
No. of Overcurrent L xW x H Master /
Voltage Amps Receptacles Plug Part No.
receptacles protection inches (mm) Expansion
60 x 1.75 x 2.25
208V 30 C13, C19 24, 6 L6-30 Breaker Master 9972.9612)
(1525 x 44 x 57)
60 x 1.75 x 2.25
208V 30 C13, C19 24, 6 L6-30 Breaker Expansion 9972.9622)
(1525 x 44 x 57)
208 3P 69 x 1.75 x 2.25
30 C13 24 L15-30 Fuse Master 9971.104
Delta (1753 x 44 x 57)
208 3P 69 x 1.75 x 2.25
30 C13 24 L15-30 Fuse Expansion 9971.105
Delta (1753 x 44 x 57)
208 3P 69 x 1.75 x 3.5
50 C13, C19 12, 12 Cord set Breaker Master 9978.450
Delta (1753 x 44 x 89)
208 3P 69 x 1.75 x 3.5
50 C13, C19 12, 12 Cord set Breaker Expansion 9978.449
Delta (1753 x 44 x 89)
208V 3P 3.5 x 17 x 10
50 L6-30 6 Cord set Breaker Master 9978.452
Delta (89 x 432 x 254)
208V 3P 3.5 x 17 x 10
50 L6-30 6 Cord set Breaker Expansion 9978.451
Delta (89 x 432 x 254)
208V 3P 3.5 x 17 x 10
60 L6-30 6 Cord set Breaker Master 9978.459
Delta (89 x 432 x 254)
208V 3P 3.5 x 17 x 10
60 L6-30 6 Cord set Breaker Expansion 9978.457
Delta (89 x 432 x 254)
208 3P 69 x 1.75 x 3.5
60 C13, C19 12, 12 Cord set Breaker Master 9978.455
Delta (1524 x 44 x 89)
208 3P 69 x 1.75 x 3.5
60 C13, C19 12, 12 Cord set Breaker Expansion 9978.453
Delta (1524 x 44 x 89)
208 3P 69 x 1.75 x 2.25
30 C13 24 L21-30 Fuse Master 9971.106
Wye (1753 x 44 x 57)
208 3P 69 x 1.75 x 2.25
30 C13 24 L21-30 Fuse Expansion 9971.107
Wye (1753 x 44 x 57)
208 3P 69 x 1.75 x 3.5
60 C13, C19 12, 12 Cord set Breaker Master 9978.456
Wye (1524 x 44 x 89)
208 3P 69 x 1.75 x 3.5
60 C13, C19 12, 12 Cord set Breaker Expansion 9978.454
Wye (1524 x 44 x 89)
208 3P 3.5 x 17 x 10
60 L6-30 6 Cord set Breaker Master 9978.460
Wye (89 x 432 x 254)
208 3P 3.5 x 17 x 10
60 L6-30 6 Cord set Breaker Expansion 9978.458
Wye (89 x 432 x 254)
IEC Red 6Hr 69 x 1.75 x 2.25
415 20 C13 24 Fuse Master 9978.462
3P+N+G (1753 x 44 x 57)
IEC Red 6Hr 69 x 1.75 x 2.25
415 20 C13 24 Fuse Expansion 9978.461
3P+N+G (1753 x 44 x 57)
69 x 1.75 x 2.25
415 30 C13 24 L22-30 Fuse Master 9978.464
(1753 x 44 x 57)
69 x 1.75 x 2.25
415 30 C13 24 L22-30 Fuse Expansion 9978.463
(1753 x 44 x 57)
2) Includes PIPS

Switched PDU
Switched PDU products include remote monitoring and management, plus reboot commands for PIPS – Per Inlet Power Sensing – provides power monitoring per inlet/infeed including
connected servers and network equipment; providing complete lights-out management of a data center current, voltage, power, apparent power and accumulated energy, replacing branch
or remote branch office. Features include the ability to reboot a single or dual-power server with one circuit monitoring with higher accuracy and lower cost monitoring of each circuit. POPS
command, receive SNMP alerts and the ability to assign specific access rights to designated outlets or – Per Outlet Power Sensing – provides information per individual outlet, including current
groups. Switched PDU products can provide power requirements for high-amperage, high-voltage branch load, voltage and power. Now power information is available per device, groups of
circuit protection and SSL & SSH security. devices, individual PDU or an entire cabinet.

No. of Overcurrent LxWxH Master /


Voltage Amps Receptacles Plug Part No.
receptacles protection inches (mm) Expansion

17.2 x 1.75 x 7.1


208-240V 30 C13 8 L6-30 Fuse Master 9978.472
(437 x 44 x 181)

17.2 x 1.75 x 7.1


208-240V 30 C13 8 L6-30 Fuse Expansion 9978.471
(437 x 44 x 181)

69 x 1.75x 2.25
208-240V 30 C13 16 L6-30 Fuse Master 9978.4682)
(1753 x 44 x 57)

69 x 1.75x 2.25
208-240V 30 C13 16 L6-30 Fuse Expansion 9978.4652)
(1753 x 44 x 57)

69 x 1.75x 2.25
208-240V 30 C13 24 L6-30 Breaker Master 9978.4692)
(1753 x 44 x 57)

69 x 1.75x 2.25
208-240V 30 C13 24 L6-30 Breaker Expansion 9978.4662)
(1753 x 44 x 57)

69 x 1.75 x 3.5
208-240V 30 C13, C19 18, 6 L6-30 Breaker Master 9978.4703)
(1753 x 44 x 89)

2) Includes PIPS 3)Includes PIPS/POPS


Switched PDU (continued)
No. of Overcurrent L xW x H Master /
Voltage Amps Receptacles Plug Part No.
receptacles protection inches (mm) Expansion

69 x 1.75 x 3.5
208-240V 30 C13, C19 18, 6 L6-30 Breaker Expansion 9978.4673)
(1753 x 44 x 89)

69 x 1.75 x 3.5
208V 3P Delta 20 C13 24 L15-20 Fuse Master 9970.773
(1753 x 44 x 89)

69 x 1.75 x 3.5
208V 3P Delta 20 C13 24 L15-20 Fuse Expansion 9970.774
(1753 x 44 x 89)

69 x 3.5 x 3.5
208V 3P Delta 30 C13 24 L15-30 Fuse Master 9970.777
(1753 x 89 x 89)

69 x 3.5 x 3.5
208V 3P Delta 30 C13 24 L15-30 Fuse Expansion 9970.778
(1753 x 89 x 89)

69 x 1.75 x 3.5
208V 3P Delta 30 C13, C19 18, 6 L15-30 Breaker Master 9978.4753)
(1753 x 44 x 89)

69 x 1.75 x 3.5
208V 3P Delta 30 C13, C19 18, 6 L15-30 Breaker Expansion 9978.4733)
(1753 x 44 x 89)

69 x 3.5 x 3.5
208V 3P Delta 50 C13, C19 12, 12 CS8365C Breaker Master 9978.479
(1753 x 89 x 89)

69 x 3.5 x 3.5
208V 3P Delta 50 C13, C19 12, 12 CS8365C Breaker Expansion 9978.477
(1753 x 89 x 89)

69 x 1.75 x 2.25
208V 3P Delta 50 C13 48 Cord Set Breaker Master 9978.480
(1753 x 44 x 57)

69 x 1.75 x 2.25
208V 3P Delta 50 C13 48 Cord Set Breaker Expansion 9978.478
(1753 x 44 x 57)

69 x 1.75 x 2.25
208V 3P Delta 60 C13, C19 12, 12 IEC Blue, 9hr 3P+G Breaker Master 9978.487
(1753 x 44 x 57)

69 x 1.75 x 2.25
208V 3P Delta 60 C13, C19 12, 12 IEC Blue, 9hr 3P+G Breaker Expansion 9978.481
(1753 x 44 x 57)

69 x 1.75 x 3.5
208V 3P Delta 60 C13 48 Cord Set Breaker Master 9978.489
(1753 x 44 x 89)

69 x 1.75 x 3.5
208V 3P Delta 60 C13 48 Cord Set Breaker Expansion 9978.483
(1753 x 44 x 89)

69 x 1.75 x 3.5
208V 3P Wye 20 C13 24 L21-20 Fuse Master 9970.771
(1753 x 44 x 89)

69 x 1.75 x 3.5
208V 3P Wye 20 C13 24 L21-20 Fuse Expansion 9970.772
(1753 x 44 x 89)

69 x 3.5 x 3.5
208V 3P Wye 30 C13 24 L21-30 Fuse Master 9970.775
(1753 x 89 x 89)

69 x 3.5 x 3.5
208V 3P Wye 30 C13 24 L21-30 Fuse Expansion 9970.776
(1753 x 89 x 89)

69 x 1.75 x 3.5
208V 3P Wye 30 C13, C19 18, 6 L21-30 Breaker Master 9978.4763)
(1753 x 44 x 89)

69 x 1.75 x 3.5
208V 3P Wye 30 C13, C19 18, 6 L21-30 Breaker Expansion 9978.4743)
(1753 x 44 x 89)

69 x 1.75 x 3.5
208V 3P Wye 60 C13, C19 12, 12 IEC, Blue 9hr, 3P+N+G Breaker Master 9978.488
(1753 x 44 x 89)

69 x 1.75 x 3.5
208V 3P Wye 60 C13, C19 12, 12 IEC, Blue 9hr, 3P+N+G Breaker Expansion 9978.482
(1753 x 44 x 89)

69 x 3.5 x 3.5
208V 3P Wye 60 C13 48 Cord Set Breaker Master 9978.490
(1753 x 89 x 89)

69 x 3.5 x 3.5
208V 3P Wye 60 C13 48 Cord Set Breaker Expansion 9978.486
(1753 x 89 x 89)

2) Includes PIPS 3) Includes PIPS/POPS

Accessories
Temperature/Humidity Sensor Description Cable length inches (mm) Packs of Part No.

07/14 • US224
n Plugs into a Smart/Switched Master Cord with temperature and
118 (3000) 1 9970.815
PDU humidity probe

Power Cord Receptacles Length inches (mm) Packs of Part No.

C19/L6-20P 117 (4500) 1 9970.811

C19/L5-20P 98 (2500) 1 9970.812


n For 20 Amp PDUs
C19/5-20P 98 (2500) 1 9970.813

C19/5-15P 118 (3000) 1 9970.814

Button Mount Bracket Description Packs of Part No.

n Enables tool-less installation of PDUs


0 U, dual recessed
n Allow 0 U mounting of PDUs 2 9963.800
button mount bracket
n Black, E-coated

Rittal Corporation
Urbana, Ohio • Houston, Texas • Sparks, Nevada • USA
Toll-free: 800-477-4000 • Fax: 800-477-4003 • Email: [email protected] • Online: www.rittal.us

You might also like