Catalogo CMP40 - CMP112 - CMPZ71 - CMPZ100 PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 424

Drive Technology \ Drive Automation \ System Integration \ Services *19381212_0315*

Catalog

Synchronous Servomotors
CMP40 – CMP112, CMPZ71 – CMPZ100

Edition 03/2015 19381212/EN


SEW-EURODRIVE—Driving the world
Table of contents

Table of contents
1 Introduction................................................................................................................................ 7
1.1 The SEW-EURODRIVE group of companies ................................................................. 7
1.2 Products and systems from SEW-EURODRIVE ............................................................ 8
1.3 Documentation ............................................................................................................. 11
1.4 Motor type notation ...................................................................................................... 12
1.5 Product names and trademarks ................................................................................... 12
1.6 Copyright notice ........................................................................................................... 12

2 Product description................................................................................................................. 13
2.1 CMP synchronous servomotors ................................................................................... 13
2.2 CMPZ synchronous servomotors – version with additional flywheel mass .................. 13
2.3 Features of CMP. servomotors .................................................................................... 13
2.4 Functional safety technology (FS) ................................................................................ 18
2.5 Corrosion and surface protection ................................................................................. 19
2.6 Important order information .......................................................................................... 21
2.7 Overview of the motors ................................................................................................ 23

3 Type designation ..................................................................................................................... 24


3.1 Variants and options of the CMP. motor series ............................................................ 24
3.2 Sample type designation of a servomotor .................................................................... 26
3.3 Example of a serial number for a servomotor .............................................................. 26

4 General project planning information ................................................................................... 27


4.1 Standards and regulations ........................................................................................... 27
4.2 Circuit breaker and protective equipment .................................................................... 29

5 Project planning ...................................................................................................................... 30


5.1 Drive and gear unit selection data ................................................................................ 30
5.2 Project planning procedure .......................................................................................... 33
5.3 Thermal characteristics ................................................................................................ 37
5.4 Operating temperatures ............................................................................................... 37
5.5 Derating for increased ambient temperature ................................................................ 38
5.6 Mechanical and electrical characteristics ..................................................................... 39
5.7 Overhung and axial loads ............................................................................................ 43
5.8 Project planning example ............................................................................................. 57
5.9 Operation on inverter ................................................................................................... 68
5.10 Maximum speeds of CMP and CMPZ motors .............................................................. 70

6 Technical data of the motors.................................................................................................. 71


6.1 Key to the technical data .............................................................................................. 71
6.2 CMP40 to CMP112, 400 V system voltage .................................................................. 72
19381212/EN – 03/2015

6.3 CMP40 to 63 with BK brake, 400 V system voltage ..................................................... 74


6.4 CMP71 to CMP100 with BP brake, 400 V system voltage ........................................... 75
6.5 CMP112 with BY brake, 400 V system voltage ............................................................ 76
6.6 CMPZ71 to CMPZ100, 400 V system voltage ............................................................. 77
6.7 CMPZ71 to CMPZ100 BY brake, 400 V system voltage .............................................. 78
6.8 Overview of combinations of CMP. with MOVIAXIS®, 400 V system voltage .............. 79
6.9 Overview of combinations of CMP. with MOVIDRIVE®, 400 V system voltage ............ 85

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 3


Table of contents

6.10 Dynamic and thermal characteristic curves, 400 V system voltage ............................. 97
6.11 CMP40 to 100, 230 V system voltage ....................................................................... 134
6.12 CMP40 to 63 with BK brake, 230 V system voltage ................................................... 135
6.13 CMP71 to 100 with BP brake, 230 V system voltage ................................................. 136
6.14 CMPZ71 to CMPZ100, 230 V system voltage ........................................................... 136
6.15 CMPZ71 to CMPZ100 with BY brake, 230 V system voltage .................................... 137
6.16 Overview of combinations of CMP. with MOVIDRIVE®, 230 V system voltage .......... 138
6.17 Dynamic and thermal characteristic curves, 230 V system voltage ........................... 143
6.18 Torque/current characteristic curves .......................................................................... 166

7 Dimension sheets for CMP. motors/brakemotors .............................................................. 170


7.1 Information about dimension sheets .......................................................................... 170
7.2 CMP40 S/M ................................................................................................................ 170
7.3 CMP50 S/M/L ............................................................................................................. 174
7.4 CMP63 S/M/L ............................................................................................................. 180
7.5 CMP.71 S/M/L ............................................................................................................ 186
7.6 CMP.80 S/M/L ............................................................................................................ 198
7.7 CMP.100 S/M/L .......................................................................................................... 210
7.8 CMP112 S/M/L/H/E ................................................................................................... 222

8 BK brakes............................................................................................................................... 232
8.1 Description of BK brakes (CMP40 to CMP63) ........................................................... 232
8.2 Principle of the BK brake ............................................................................................ 233
8.3 General information about BK brakes ........................................................................ 234
8.4 Selecting the BK brake ............................................................................................... 235
8.5 Important design information ...................................................................................... 236
8.6 BK brake project planning .......................................................................................... 237
8.7 Technical data of BK brakes ...................................................................................... 241
8.8 Dimensioning and routing of the cable ....................................................................... 243
8.9 Selecting the braking contactor .................................................................................. 243
8.10 Block diagram of brake control – plug connectors ..................................................... 244
8.11 Block diagram of brake control – terminal box ........................................................... 246
8.12 Dimensions drawings for BK brake controls .............................................................. 247

9 BP brakes ............................................................................................................................... 248


9.1 Description of BP brakes (CMP71 to CMP100) ......................................................... 248
9.2 Principle of the BP brake ............................................................................................ 249
9.3 General information about BP brakes ........................................................................ 250
9.4 Selecting the BP brake ............................................................................................... 251
9.5 Important design information ...................................................................................... 252
9.6 BP brake project planning .......................................................................................... 253
19381212/EN – 03/2015

9.7 Technical data of BP brakes ...................................................................................... 256


9.8 Dimensioning and routing of the cable ....................................................................... 259
9.9 Selecting the braking contactor .................................................................................. 259
9.10 Block diagram of brake control – plug connectors ..................................................... 260
9.11 Block diagram of brake control – terminal box ........................................................... 262
9.12 Dimension drawings for BP brake controls ................................................................ 263

4 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Table of contents

10 BY brakes ............................................................................................................................... 264


10.1 Description of BY brakes (CMPZ71 to CMPZ100, CMP112) ..................................... 264
10.2 Principle of the BY brake ............................................................................................ 265
10.3 General information .................................................................................................... 265
10.4 Selecting the BY brake ............................................................................................... 266
10.5 Important design information ...................................................................................... 267
10.6 BY brake project planning .......................................................................................... 268
10.7 Technical data of BY brakes ...................................................................................... 273
10.8 Dimensioning and routing the cable for terminal boxes ............................................. 283
10.9 Selecting the braking contactor .................................................................................. 283
10.10 Selecting the brake control system ............................................................................ 284
10.11 Block diagram of brake control – plug connectors ..................................................... 286
10.12 Block diagram of brake control – terminal box ........................................................... 293
10.13 Dimension drawings for BY brake control .................................................................. 297
10.14 Safety-rated BY..(FS) brakes ..................................................................................... 298

11 Motor types ............................................................................................................................ 305


11.1 Standard type – encoders .......................................................................................... 305
11.2 Standard type – motor protection ............................................................................... 313
11.3 Standard type – connection options ........................................................................... 316
11.4 Additional feature – forced-cooling fan ....................................................................... 336

12 Prefabricated cables ............................................................................................................. 341


12.1 Description ................................................................................................................. 341
12.2 Project planning for cable cross section ..................................................................... 342
12.3 Cable assignment: CMP and CMPZ, 400 V system voltage ...................................... 344
12.4 Cable assignment: CMP /VR and CMPZ /VR, 400 V system voltage ........................ 347
12.5 Cable assignment: CMP /BP /BK, 400 V system voltage .......................................... 350
12.6 Cable assignment: CMP /BP / BK /VR, 400 V system voltage .................................. 352
12.7 Cable assignment: CMP /BY, 400 V system voltage ................................................. 354
12.8 Cable assignment: CMP /BY /VR, 400 V system voltage .......................................... 355
12.9 Cable assignment: CMPZ /BY, 400 V system voltage ............................................... 356
12.10 Cable assignment: CMPZ /BY /VR, 400 V system voltage ........................................ 358
12.11 Cable assignment: CMP and CMPZ, 230 V system voltage ...................................... 360
12.12 Cable assignment: CMP /VR and CMPZ /VR, 230 V system voltage ........................ 362
12.13 Cable assignment: CMP /BP /BK, 230 V system voltage ......................................... 363
12.14 Cable assignment: CMP /BP /VR, 230 V system voltage .......................................... 365
12.15 Cable assignment: CMPZ /BY, 230 V system voltage ............................................... 366
12.16 Cable assignment: CMPZ /BY /VR, 230 V system voltage ........................................ 367
12.17 Encoder cable assignment: Plug connector connection option /KKS ........................ 368
12.18 Encoder cable assignment: Connection option KK .................................................... 368
19381212/EN – 03/2015

12.19 Forced cooling fan cables .......................................................................................... 368


12.20 Structure of prefabricated cables for CMP. servomotors ........................................... 369
12.21 Power cables ............................................................................................................. 372
12.22 Encoder cables .......................................................................................................... 380
12.23 Forced cooling fan cables .......................................................................................... 386
12.24 Cable specifications of power cables ......................................................................... 388

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 5


Table of contents

12.25 Cable specification of encoder cables ........................................................................ 392


12.26 Cable specifications of forced cooling fan cables ...................................................... 394

13 Appendix ................................................................................................................................ 396


13.1 Cable dimensions to AWG ......................................................................................... 396

14 Address Directory ................................................................................................................. 397

Index ....................................................................................................................................... 417

19381212/EN – 03/2015

6 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Introduction
The SEW-EURODRIVE group of companies 1
1 Introduction 1

1.1 The SEW-EURODRIVE group of companies


1.1.1 Global presence
Driving the world – with innovative drive solutions for all industries and for every appli-
cation. Products and systems from SEW‑EURODRIVE are used all over the world. Be
it in the automotive, building materials, food and beverage or metal-processing indus-
try: The decision to use drive technology "made by SEW‑EURODRIVE" stands for reli-
ability for both functionality and investment.
We are represented in the most important branches of industry all over the world: with
14 manufacturing plants and 79 Drive Technology Centers worldwide as well as our
customer support, which we consider an integrative service that continues our commit-
ment to outstanding quality.

1.1.2 Always the right drive


The SEW‑EURODRIVE modular concept offers millions of combinations. This wide
selection enables you to choose the correct drive for all applications, each based on
the required speed and torque range, available space, and ambient conditions. Gear
units and gearmotors offering a unique and finely tuned performance range and the
best economic prerequisites to meet your drive requirements.
The modular DR.. motor series includes the energy-efficient motor types IE1 to IE4
and was designed and constructed with all worldwide requirements for energy efficien-
cy classes in mind. The DR.. motor easily met the requirements for approval and cer-
tification in all relevant countries. The energy-efficient drives achieve the highest effi-
ciency in combination with SEW‑EURODRIVE gear units.
The gearmotors are electronically enhanced by MOVITRAC® frequency inverters,
MOVIDRIVE® drive inverters, and MOVIAXIS® multi-axis servo inverters – a combina-
tion that blends perfectly with the existing SEW‑EURODRIVE program. As is the case
with the mechanical systems, all development, production, and assembly is carried out
entirely by SEW‑EURODRIVE. In combination with our drive electronics, these drives
provide the utmost in flexibility.
Products of the servo drive system, such as low backlash servo gear units, compact
servomotors, or MOVIAXIS® multi-axis servo inverters ensure precision and dynamics.
From single-axis or multi-axis applications to synchronized process sequences, servo
drive systems from SEW-EURODRIVE enable flexible and customized implementation
of your applications.
For economical, decentralized installations, SEW‑EURODRIVE offers components
from its decentralized drive system, such as MOVIMOT®, the gearmotor with integra-
ted frequency inverter, or MOVI-SWITCH®, the gearmotor with integrated switching
and protection function. SEW‑EURODRIVE has developed hybrid cables to provide
cost-effective functional solutions, irrespective of the system philosophy or scope. The
latest developments from SEW-EURODRIVE: DRC.. electronic motor, MOVIGEAR®
mechatronic drive system, MOVIFIT® decentralized drive controller, MOVIPRO® de-
centralized drive, positioning, and application controller, as well as MOVITRANS® sys-
19381212/EN – 03/2015

tem components for contactless energy transfer.


Power, quality, and robustness combined in a single standard product: with
SEW‑EURODRIVE, powerful movements are delivered by industrial gear units with
high torques. The modular concept once again ensures optimum adaptation of indus-
trial gear units to meet a wide range of different applications.

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 7


1 Introduction
Products and systems from SEW-EURODRIVE

1.1.3 Your ideal partner


Its global presence, extensive product range and broad spectrum of services make
SEW‑EURODRIVE the ideal partner for the machinery and plant construction industry
when it comes to providing drive systems for demanding drive tasks in all industries
and applications.

1.2 Products and systems from SEW-EURODRIVE


The products and systems by SEW‑EURODRIVE are divided into the following prod-
uct groups:
• Industrial gear units
• Gearmotors and frequency inverters
• Servo drive systems
• Decentralized drive systems
• VARIOLUTION® and MAXOLUTION®
Products and systems used in several group applications are listed in a separate
group entitled "Products and systems covering several product groups". Consult the
following tables to locate the products and systems included in the respective product
group:

Industrial gear units


• X, MC, ML helical and bevel-helical gear units
• P002 - 102 series planetary gear units
• P.MC.., P.X.. series helical and bevel-helical planetary gear units
• Application solutions with connections
– Swing base
– Gearmotor
– Motor
– Coupling
– Brake
– Lubrication system
For conveyor drives, bucket conveyors, agitators, cooling towers, crane systems, and much more.
19381212/EN – 03/2015

8 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Introduction
Products and systems from SEW-EURODRIVE 1
Gearmotors and frequency inverters 1
Gear units / gearmotors Motors Frequency inverters
• Helical gear units and gearmo- • Asynchronous AC motors and • MOVITRAC® frequency inver-
tors brakemotors ters
• Parallel-shaft helical gear units • Pole-changing AC motors and • MOVI4R-U®
and gearmotors brakemotors frequency inverters
• Helical-bevel gear units and • Energy-efficient motors • MOVIDRIVE® drive inverters
gearmotors
• Explosion-proof AC motors and • Control, technology, and com-
• Helical-worm gear units and brakemotors munication options for inverters
gearmotors
• Torque motors
• SPIROPLAN® right-angle gear- • Single-phase motors and
motors brakemotors
• Drives for electrified monorail • Asynchronous linear motors
systems
• Geared torque motors
• Pole-changing gearmotors
• Variable-speed gear units and
gearmotors
• Aseptic gearmotors
• Explosion-proof gear units and
gearmotors
• Explosion-proof variable-speed
gear units and gearmotors

Servo drive systems


Servo gear units / Servomotors Servo drive inverters /
servo gearmotors servo inverters
• Low backlash planetary servo • Asynchronous servomotors / • MOVIDRIVE® servo drive inver-
gear units / planetary gearmo- servo brakemotors ters
tors • MOVIAXIS® multi-axis servo in-
• Synchronous servomotors
• Low backlash helical-bevel ser- • verters
Explosion-proof servomotors /
vo gear units / helical-bevel servo brakemotors • Control, technology and com-
gear units munication options for servo
• Synchronous linear motors
• R, F, K, S, W gear units / gear- drive inverters and servo inver-
motors ters
• Explosion-proof servo gear
units / servo gearmotors
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 9


1 Introduction
Products and systems from SEW-EURODRIVE

Decentralized drive systems


Decentralized drives Communication and installation Contactless energy transfer
• DRC.. electronic mo- • Fieldbus interfaces • MOVITRANS® system
tors / MOVIGEAR® mechatronic • Field distributors for decentral- – Stationary components for
drive system ized installation energy supply
– DBC – Direct Binary Com- • MOVIFIT® product range – Mobile components for en-
munication
®
– MOVIFIT FDC for control- ergy consumption
– DAC – Direct AS-Interface ling MOVIGEAR® and DRC.. – Line cables and installation
Communication drive units material
– DSC – Direct SBus Commu- – MOVIFIT® MC for controlling
nication MOVIMOT® drives
– SNI – Single Line Network – MOVIFIT® SC with integra-
Installation ted electronic motor switch
• MOVIMOT® gearmotors with in- – MOVIFIT® FC with integra-
tegrated frequency inverter ted frequency inverter
• MOVIMOT® motors / brakemo- • MOVIPRO® product line
tors with integrated frequency
inverter – MOVIPRO® SDC decentral-
ized drive and positioning
• MOVI‑SWITCH® gearmotors control
with integrated switching and
protection function
• MOVI‑SWITCH® motors /
brakemotors with integrated
switching and protection func-
tion
• Explosion-proof MOVIMOT®
and MOVI‑SWITCH® gearmo-
tors

VARIOLUTION® and MAXOLUTION®


• VARIOLUTION® packages for high technical solution expertise in plants and machines
• MAXOLUTION® systems for customer-specific system solutions and plants

Products and systems covering several product groups


• Operator panels
• MOVI‑PLC® drive-based control system
• Components of the type "functional safety"
• Diagnostic units
19381212/EN – 03/2015

10 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Introduction
Documentation 1
In addition to products and systems, SEW‑EURODRIVE offers a comprehensive 1
range of services. These include:
• Technical consulting
• User software
• Seminars and training
• Extensive technical documentation
• Worldwide customer service
Visit our website at
www.sew‑eurodrive.com
The website provides comprehensive information and services.

1.3 Documentation

1.3.1 Contents of this publication


This catalog provides a detailed description of the following product groups offered by
SEW‑EURODRIVE:
• Synchronous servomotors of the CMP and CMPZ series
• Options and accessories for motors
This price catalog/catalog includes the following information:
• Type designations
• Product descriptions
• Project planning information
• Technical data
• Technical data of the options and additional features
• Dimension sheets
• Information on brakes from SEW‑EURODRIVE
• Information on prefabricated cables
• In the price catalog: Prices and surcharges for additional features and options

1.3.2 Additional documentation


The following documents are available from SEW-EURODRIVE in addition to this
"Synchronous Servomotors" catalog:
• Synchronous servo gearmotors
• Asynchronous servo gearmotors
• AC motors
19381212/EN – 03/2015

• Explosion-proof AC motors
• Gearmotors
• Explosion-proof drives
• Geared torque motors

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 11


1 Introduction
Motor type notation

1.4 Motor type notation


This catalog covers among others the motor types CMP and CMPZ.
If information refers to both CMP and CMPZ motors, the notation CMP. motors is
used.
If information refers to either CMP or CMPZ motors, the motor type is stated explicitly.

1.5 Product names and trademarks


The brands and product names in this documentation are trademarks or registered
trademarks of their respective titleholders.

1.6 Copyright notice


© 2015 SEW‑EURODRIVE. All rights reserved.
Unauthorized reproduction, modification, distribution or any other use of the whole or
any part of this documentation is strictly prohibited.

19381212/EN – 03/2015

12 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Product description
CMP synchronous servomotors 2
2 Product description
2
2.1 CMP synchronous servomotors
The CMP servomotor series combines high dynamics, high torques, and precision in a
compact design.
Their innovative design with the latest in winding and magnet technology offers a mo-
tor system with optimum dynamics and the best control characteristics at the smallest
space. The cast stator protects the motor against vibrations and humidity.
Characteristics of SEW-EURODRIVE synchronous servomotors:
• Static torque from 0.5 to 95 Nm
• High dynamics (ratio between rated torque and mass moment of inertia of the mo-
tor)
• High degree of protection (IP65)
• Robust encoder system (resolver)
• The optimal encoder system with sine/cosine encoder allows for a very wide setting
range and absolute position detection,
• High continuous torque at low speeds and at standstill, without forced cooling fan
• High overload capability
• NeFeB magnets, permanent magnets with high magnetic flux density.
CMP motors can be optionally equipped with a holding brake and a forced cooling fan.
CMP servomotors can be combined with MOVIDRIVE® inverters and MOVIAXIS® mul-
ti-axis servo inverters.

2.2 CMPZ synchronous servomotors – version with additional flywheel mass


CMPZ synchronous servomotors are equipped with an internal additional flywheel
mass. These motors combine high torques and precision in a compact design and
provide particularly favorable control characteristics with high external masses. Fur-
thermore, the internal higher moment of inertia allows for a smaller gear ratio.
In addition to the above mentioned features of the CMP motors, CMPZ motors are op-
tionally available with a powerful BY working brake with high working capacity and op-
tional manual brake release.

2.3 Features of CMP. servomotors


Synchronous servomotors with permanent magnets offer highest dynamic overload
capacity.
State-of-the-art winding and magnet technology enable a compact motor system with
great dynamic qualities, smooth running and excellent control characteristics.
19381212/EN – 03/2015

2.3.1 Standard features


Synchronous servomotors of the CMP. series constitute a drive system that comprises
the following elements in its basic variant:
• Smooth shaft end
• Resolver as encoder

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 13


2 Product description
Features of CMP. servomotors

• Thermal motor protection through temperature sensing


• Connection via adjustable plug connectors
• High degree of rotational accuracy
• High vibration class (DIN EN 60034‑14 grade B).

2.3.2 Optional product characteristics


CMP. motors can be optionally expanded with:
• Shaft end with key
• Forced cooling fan
• Connection via radial plug connectors
• Connection with mating connector
• Connection via terminal box
• Prefabricated cables
• Holding brake with DC 24 V brake voltage
• BK permanent magnet brake
• BY working brake with manual brake release
• Safety-rated encoder
• UL or UL/CSA approval
• Direct mounting to SEW gear units with B5 flange
Alternatives can be selected instead of the elements of the basic variant, e.g. absolute
encoder with Hiperface® instead of the resolver and electronic nameplate.

2.3.3 Torque
The 7 available sizes cover a torque range from 0.5 Nm to 95 Nm.
The dynamic peak torque reaches 1.9 Nm to 320 Nm.

2.3.4 Rated speeds


The optimized winding makes it possible to select one of three speeds:
• 2000 rpm
• 3000 rpm
• 4500 rpm
• 6000 rpm

2.3.5 Number of poles


CMP motors are available with the following number of poles.
19381212/EN – 03/2015

Motor Number of poles


CMP40 – CMP63 6
CMP.71 – CMP.100 10
CMP112 6

14 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Product description
Features of CMP. servomotors 2
2.3.6 Operating temperatures
Motors of the CMP series are designed for use in a temperature range between ‐20 °C 2
and +40 °C.
Motors for cold storage applications can be used down to -40 °C. The temperature
range from -40 °C to +10 °C is listed on the nameplate.
If the motors are operated outside the specified temperature range, observe the notes
in chapter Operating temperatures (→ 2 37).

2.3.7 Direct mounting


CMP. servomotors can be mounted directly without adapter to the respective
SEW‑EURODRIVE gear unit.
The following gear units can be selected:
• BS.F helical-bevel servo gear units
• PS.F and PS.C planetary servo gear units
• R.. helical gear units
• F.. parallel-shaft helical gear units
• K.. helical-bevel gear units
• S.. helical-worm gear units
• SPIROPLAN® gear units

2.3.8 Output variants


CMP. servomotors are available with the following output types:
• Stand-alone motors with IEC/EN flange with through bores based on IEC 60072‑1:
1991 and EN 50347: 2003.
• With square flange for mounting to the gear unit types BS.F, PS.F, PS.C, W10 –
W30.
• With round flange for mounting to the gear unit types R, F, K, S, W37, W47. The
flange dimensions are implemented according to the SEW‑EURODRIVE work
standards for gear unit mounting.

2.3.9 Noise levels


The noise levels of all motors from SEW‑EURODRIVE are well within the maximum
permitted noise levels set forth in IEC/EN 60034-9.

2.3.10 Painting
CMP. motors are painted with black machine paint RAL 9005 as per DIN 1843 as
standard. Special coatings and other colors are available on request.
19381212/EN – 03/2015

2.3.11 Air admission and accessibility


The motors/brakemotors must be mounted on the driven machine in such a way that
there is enough axial and radial space left for unimpeded air admission and for per-
forming maintenance on the brake.

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 15


2 Product description
Features of CMP. servomotors

2.3.12 Brakemotors
The motors can be equipped with an integrated mechanical brake on request.
The brake is controlled by a brake controller that is either installed in the inverter or
separately in the control cabinet.

BP brake / BK brake
BP and BK brakes are DC-operated electromagnetic disk brakes. They release electri-
cally, and brake using spring force (BP brakes) or magnetic force (BK brakes). The
brakes are applied automatically if the power fails. This means they meet the basic
safety requirements. The brakes cannot be retrofitted and usually operate without
brake rectifier or brake control unit.

BY brake
This is a DC-operated electromagnetic disk brake that is released electrically and ap-
plied with spring force. A characteristic feature of this brake is its extremely short de-
sign. The brake endshield is a part of both the motor and the brake. The integrated
construction of the SEW‑EURODRIVE brakemotor permits particularly compact and
sturdy solutions.
The brake can also be released mechanically if it is equipped with manual brake re-
lease. In this case, a lockable hand lever with automatic reset is included in the deliv-
ery.
The BY brake is also available as safety-rated brake for use in functional safety appli-
cations. In this case (FS) is added to the name.

19381212/EN – 03/2015

16 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Product description
Features of CMP. servomotors 2
2.3.13 International markets
On request, SEW‑EURODRIVE supplies motors registered for the North American 2
market or certified motors with connection conditions according to the relevant regula-
tions.

Mark Meaning
CE mark to state compliance with European guidelines, such as
the Low Voltage Directive.

ATEX mark to state compliance with the European Directive


94/9/EC.

UR mark to confirm that UL (Underwriters Laboratory) is informed


about the registered components; register number by UL:
E337323
CSA mark to confirm the Canadian Standard Association (CSA)
and the market conformity of AC motors.

EAC mark (EurAsian Conformity)


Confirms compliance with the regulations of the economic and
customs union of Russia, Belarus and Kazakhstan.
UkrSEPRO mark (Ukrainian Certification of Products)

013
Confirms compliance with the technical regulations of the country
Ukraine.
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 17


2 Product description
Functional safety technology (FS)

2.4 Functional safety technology (FS)


SEW‑EURODRIVE motors can be supplied with safety-rated components on request.
SEW‑EURODRIVE indicates such an integration by the FS mark and a number on the
nameplate.
The number is a code that indicates which components in the motor are safety-rela-
ted. See the following excerpt from the code table for all products:

Functional Inverter Motor monitoring Encoder Brake Brake monitoring Manual


safety (e.g. motor protec- (e.g. function) brake re-
tion) lease
01 x
02 x
03 x
04 x
05 x x
06 x x
07 x x
08 x x
09 x x
10 x x
11 x x
If the FS logo on the nameplate contains the code "FS 04", for example, the motor is
equipped with a safe encoder.
You can determine the safety level of machines and plants using the safety parame-
ters provided in chapter "Technical data"
The characteristic safety values of SEW components are also available on the SEW
homepage on the Internet and in the SEW library for the Sistema software of the Insti-
tute for Occupational Safety and Health of the German Social Accident Insurance
(IFA, formerly BGIA).

19381212/EN – 03/2015

18 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Product description
Corrosion and surface protection 2
2.5 Corrosion and surface protection
2.5.1 General information 2
SEW‑EURODRIVE offers various optional protective measures for operating motors
under special environmental conditions.
These preventive measures comprise two groups:
• KS corrosion protection
• OS surface protection
For motors, optimal protection is offered through a combination of KS corrosion pro-
tection and OS surface protection.

2.5.2 KS corrosion protection


KS corrosion protection for motors comprises the following measures:
• All retaining screws that are loosened during operation are made of stainless steel.
• Various motor parts are coated with a finishing varnish.
• The flange contact surfaces and shaft ends are treated with a temporary rust pre-
ventive.
• Additional measures for brakemotors.
A sticker labeled "KORROSIONSSCHUTZ" (corrosion protection) on the motor indi-
cates that special treatment has been applied.
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 19


2 Product description
Corrosion and surface protection

2.5.3 OS surface protection


In addition to the standard surface protection, motors and gear units are available with
surface protection OS1 to OS4. The special measure "Z" is also available in addition.
Special measure "Z" means that large contour recesses are filled with rubber before
painting.

Surface protection1) Ambient conditions Sample applications


Standard Suitable for machines and systems within build- • Machines and systems in the
ings and interior rooms with neutral atmos- automobile industry
pheres. • Transport systems in logistics
Similar to corrosivity category2) : • Conveyor belts at airports
• C1 (negligible)
OS1 Suited for environments prone to condensation • Systems in saw mills
and atmospheres with low humidity or contami- • Hall gates
nation, such as applications outdoors under
roof or with protection. • Agitators and mixers
According to corrosivity category2):
• C2 (low)
OS2 Suited for environments with high humidity or • Applications in amusement
moderate atmospheric contamination, such as parks
applications outdoors subject to direct weather- • Funiculars and chair-lifts
ing.
• Applications in gravel plants
According to corrosivity category2):
• Systems in nuclear power
• C3 (moderate) plants
OS3 Suitable for environments with high humidity • Sewage treatment plants
and occasionally severe atmospheric and • Port cranes
chemical contamination. Occasionally acidic or
caustic wet cleaning. Also for applications in • Mining applications
coastal areas with moderate salt load.
According to corrosivity category2):
• C4 (high)
OS4 Suitable for environments with permanent hu- • Drives in malting plants
midity or severe atmospheric or chemical con- • Wet areas in the beverage in-
tamination. Regular acidic and caustic wet dustry
cleaning, also with chemical cleaning agents.
• Conveyor belts in the food in-
According to corrosivity category2): dustry
• C5-1 (very high)
1) IP56 and IP66 motors/brakemotors are only available with OS2, OS3 or OS4 surface protection.
2) According to DIN EN ISO 12944-2, classification of ambient conditions
19381212/EN – 03/2015

20 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Product description
Important order information 2
2.6 Important order information
2.6.1 Connection with plug connector 2
The power or power + brake of CMP. motors are connected to the motor as standard
with an adjustable, right-angle connector.
The “adjustable” position was defined for angled connectors [1]. If not specified other-
wise in the order, the adjustable connector position is delivered in the 270° variant.
The “radial” position was defined for straight connector housings (radial output). Radial
connectors [2] are optional for sizes 40 to 100.
You find detailed information about available plug connectors in chapter Connection
variants (→ 2 322).
[2]

[1]

4792369803

[1] "Adjustable" connector position [2] "Radial" connector position

The various plug connectors of the individual motor sizes are available in various
types. The following table shows the options:

Connector position Plug connector


SM1/SB1 SMB/SBB SMC/SBC
Radial X X –
Adjustable Position can be chosen when — – X
placing the order
Positions are steplessly adjusta- X X –
ble
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 21


2 Product description
Important order information

2.6.2 Connection with terminal box

Position of terminal box and cable entry


The product standard EN 60034 specifies that the following designations have to be
used for motor terminal box positions:
• As viewed onto the output shaft = A‑end
• Designation as R (right), B (bottom), L (left) and T (top)
This new designation applies to motors without a gear unit in mounting position B3
(= M1). For gearmotors, the previous designation is retained.
The position of the motor terminal box has so far been specified with 0°, 90°, 180° or
270° as viewed onto the fan guard = B‑end.
The following figure shows both designations. Where the mounting position of the mo-
tor changes, "R", "B", "L" and "T" are rotated accordingly.
The cable entry position is specified with x, 1, 2, 3.
Unless other information is provided regarding the terminal box, the 270° design with
"x" cable entry will be supplied (see figure below).
270°
X
T

0° R L 180°

X B X

90°
4792373515

CMP50 – CMP63
KK
2 3

CMP.71 – CMP.100, CMP112


KK
2 3
KKS
1
x
19381212/EN – 03/2015

9007204047116171

22 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Product description
Overview of the motors 2
2.6.3 Connecting the forced cooling fan
The position of the cable entry of the forced cooling fan is delivered as shown in the 2
dimension sheets. Cable entry turned by 180° is available on request.

2.7 Overview of the motors


2.7.1 CMP. servomotors, 230/400 V system voltage

Motor type M0 Mpk JMot CMP JMot CMPZ


Nm Nm 10-4 kgm2
CMP40S 0.5 1.9 0.10 –
CMP40M 0.8 3.8 0.15 –
CMP50S 1.3 5.2 0.42 –
CMP50M 2.4 10.3 0.67 –
CMP50L 3.3 15.4 0.92 –
CMP63S 2.9 11.1 1.15 –
CMP63M 5.3 21.4 1.92 –
CMP63L 7.1 30.4 2.69 –
CMP.71S 6.4 19.2 3.04 9.32
CMP.71M 9.4 30.8 4.08 10.37
CMP.71L 13.1 46.9 6.18 12.47
CMP.80S 13.4 42.1 8.78 27.18
CMP.80M 18.7 62.6 11.9 30.3
CMP.80L 27.5 107 18.1 36.51
CMP.100S 25.5 68.3 19.34 79.76
CMP.100M 31 108 26.25 86.66
CMP.100L 47 178.8 40 100.41
CMP112S 30 88 74 –
CMP112M 45 136 103 –
CMP112L 69 225 163 –
CMP112H 83 270 193 –
CMP112E 95 320 222 –
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 23


3 Type designation
Variants and options of the CMP. motor series

3 Type designation
3.1 Variants and options of the CMP. motor series
3.1.1 Synchronous servomotors

Designation
CMP... Flange motor size 40 / 50 / 63 / 71 / 80 / 100 / 112
CMPZ... Flange motor size 71 / 80 / 100 with additional inertia / in-
creased mass moment of inertia
S–E S = Small / M = Medium / L = Long / H = Huge / E = Extra long

3.1.2 Mechanical attachments

Designation Option
/BP Holding brake for CMP71 to 100
/BK Holding brake for CMP40 to 63
/BY Working brake for CMPZ71 to 100, CMP112
Optionally available as safety-rated brake for CMPZ71 to 100.
/HR BY manual brake release for CMP.71 to 100, CMP112 with
automatic disengaging function

3.1.3 Temperature sensor / temperature detection

Designation Option
/KY Temperature sensor (standard)
/TF Temperature sensor for CMP.71 to CMP112

3.1.4 Encoders

Designation Option
/RH1M Resolver (standard)
/ES1H Single-turn Hiperface® encoder, spread shaft, high resolution
for CMP50 and CMP63
/AS1H Multi-turn Hiperface® encoder, spread shaft, high resolution for
CMP50 and CMP63
/EK0H Single-turn Hiperface® encoder, cone shaft, for CMP40
/AK0H Multi-turn Hiperface® encoder, cone shaft, for CMP40 to 63,
CMP.71 to 100, CMP112, optionally available as safety-rated
19381212/EN – 03/2015

encoder
/EK1H Single-turn Hiperface® encoder, cone shaft, high resolution, for
CMP40 to 63, CMP.71 to 100, CMP112
/AK1H Multi-turn Hiperface® encoder, cone shaft, for CMP50
to 63/BK, CMP.71 to 100, CMP112, optionally available as
safety-rated encoder

24 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Type designation
Variants and options of the CMP. motor series 3
3.1.5 Connection options

Designation Option
/SM1 M23 motor plug connector, socket on motor end only, plugga- 3
ble motor and encoder cables (standard)
/SMB M40 motor plug connector, socket on motor end only, plugga-
ble motor and encoder cables (standard)
/SMC M58 motor plug connector, socket on motor end only, plugga-
ble motor and encoder cables (standard)
/SB1 M23 brakemotor plug connector, socket on motor end only,
pluggable motor and encoder cables (standard)
/SBB M40 brakemotor plug connector, socket on motor end only,
pluggable motor and encoder cables (standard)
/SBC M58 brakemotor plug connector, socket on motor end only,
pluggable motor and encoder cables (standard)
/KK Terminal box for CMP50, CMP63, CMP.71 to 100, clampable
motor and encoder cable
/KKS Terminal box for CMP.71 to 100, CMP112, clampable motor
cable and pluggable encoder cable

3.1.6 Ventilation

Designation Option
/VR Forced cooling fan (from size 50)
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 25


3 Type designation
Sample type designation of a servomotor

3.2 Sample type designation of a servomotor


The following figure shows an example of a type designation:

Example: CMP112M /BY/HR/KY/RH1M/VR/KK


Synchronous servomotor CMP112 Flange motor size 112
Length M Medium
Mechanical attachments /BY BY working brake
Motor option /HR Manual brake release (only for BY
brake)
Standard equipment: temperature /KY KY temperature sensor
sensor TF
Encoder motor option /RH1M Resolver (standard)
Fan motor option /VR Forced cooling fan
Connection motor option /KK Terminal box

3.3 Example of a serial number for a servomotor


The following figure shows an example of a serial number:

Example: 01. 12212343 01. 0001. 14


01. Sales organization
12212343 Order number (8 digits)
01. Order item (2 digits)
0001 Quantity (4 digits)
14 End digits of the year of manufacture (2 dig-
its)

19381212/EN – 03/2015

26 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


General project planning information
Standards and regulations 4
4 General project planning information
4.1 Standards and regulations
4.1.1 Conformance to standards
4
Servo (brake)motors from SEW‑EURODRIVE conform to the relevant standards and
regulations, in particular to:
• IEC 60034‑1, EN 60034‑1
Electrical rotating machinery, rating and performance.
• IEC 60034-2, EN 60034‑2
Rotating electrical machines, determining losses and efficiency.
• IEC 60034-9, EN 60034‑9
Rotating electrical machines, noise limits.
• IEC 60034-14, EN 60034‑14
Rotating electrical machines, vibration levels.
• EN 60529, IEC 60034‑5, EN 60034‑5
IP degree of protection for housings.
• IEC 60072
Dimensions and performance of electrical rotating machinery.
• EN 50262
Metric threads of cable glands.
• EN 50347
Standardized dimensions and power ranges.

4.1.2 Conformity with directives


Servo (brake)motors from SEW‑EURODRIVE comply with the following directives:
• Low-Voltage Directive 2006/95/EC
• Machinery Directive 2006/42/EC
• EMC Directive 2004/108/EC
• CSA C22.2 No.100‑04
• UL 1004
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 27


4 General project planning information
Standards and regulations

4.1.3 Rated data


The specific data of a synchronous servomotor are:

• Size • Static torque


• Rated speed • Rated current
• Peak current • System voltage
• Degree of protection • Thermal class
This data is given on the nameplate of the motor. In accordance with IEC 34
(EN 60034), the nameplate data applies to a maximum ambient temperature of 40 °C
and a maximum altitude of 1000 m above sea level.
Example: Nameplate of a CMP servo brakemotor

76646 Bruchsal/Germany
3ph~IEC60034
CMPZ71M/BY/KY/RH1M/SB1
01.4108673301.0001.15
M o 9.4 Nm M pk 30.8 Nm I o 7.5 A I max 39.0 A
VT nN 0 - 3000 r/min fn 250 Hz IP 65
U sys 400 V Th.Kl. F
Up 256 V Ubr 218-243 ACV Mbr 20 Nm BME1.5

IM B5 kg13.544

1333 930 3 nur Umrichterbetrieb Made in Germany

18014406693116939

The FS logo on the upper edge of the nameplate is only present if the motor has been
designed accordingly and if it includes safety-rated components. The FS logo on the
nameplate is based on the combination of safety-related components that is installed,
see Code table (→ 2 18)
The following figure shows a nameplate of a motor with UL and CSA approvals and
safety-rated components:

76646 Bruchsal/Germany
[1]
[2] 01.1900237333.0001.14 04
CMP80M/KY/AK0H/SM1
M o 18.7 Nm M pk 62.6 Nm I o 13.4 A I max 69.0 A
VT nN 0 - 3000 r/min fn 250 Hz IP 65 3 Phase
U sys 400 V Th.Kl. F ML 01 TENV
Up 283 V

IM B5 kg15.000

1342 168 9 Inverter duty VPWM Made in Germany


19381212/EN – 03/2015

9007207438377867

[1] FS mark including number


[2] Motor identification number

28 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


General project planning information
Circuit breaker and protective equipment 4
4.2 Circuit breaker and protective equipment
4.2.1 Preventive measures
Synchronous servomotors must be protected against overload and short circuit.
Install the motors with sufficient space for air to cool them. 4
The surface temperature may be in excess of 100 °C during operation in accordance
with thermal classification F. Therefore, measures to prevent inadvertent contact are
essential.
The motors are equipped with temperature detection to protect the motor winding
against overheating.
The temperature is measured by temperature sensors KTY 84 to 130 installed as
standard, or, for sizes 71 to 112 by optionally available /TF temperature sensors. The
correct model must be activated in the servo inverter to enable thermal motor protec-
tion (I2t, effective current monitoring). For information on the procedure, refer to the
documentation of the servo inverter.

4.2.2 EMC measures


SEW‑EURODRIVE synchronous servomotors are intended as components for instal-
lation in machinery and systems. The designer of the machine or system is responsi-
ble for complying with EMC Directive 2004/108/EC.

Routing brake cables


Brake and power cables may only be routed together if either the brake cable or the
power cable is shielded. We recommend that you use prefabricated cables (→ 2 341).

Notes on encoder connection


Observe the following notes when connecting an encoder:
• Use only a shielded cable with twisted pair conductors.
• Connect the shield to the PE potential on both ends over a large surface area.

Thermal motor protection


The cables can only be routed together if either the KTY cable or the power cable is
shielded. We recommend that you use prefabricated cables (→ 2 341).
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 29


5 Project planning
Drive and gear unit selection data

5 Project planning
5.1 Drive and gear unit selection data
The data of the application must be known for projecting a drive. The abbreviations
used for project planning are summarized in the following table:

Designation Meaning Unit


φ Rotational clearance `
η Gear unit efficiency for Mapk
a, b, f Gear unit constants as regards the overhung load conversion mm
c Gear unit constants as regards the overhung load conversion Nm
a0, a1, a2 Gear unit constants as regards the rise in temperature in the gear unit
FA Axial load (tension and compression) on the output shaft N
fk Speed ratio
FR Overhung load on the output shaft N
FRapk Maximum permitted overhung load at the output shaft for short-time duty (load N
application point is the middle of the shaft end)
FRamax Maximum permitted overhung load at the output shaft for continuous duty (load N
application point is the middle of the shaft end)
FRepk Maximum permitted overhung load at the input shaft for short-time duty (load N
application point is the middle of the shaft end)
FRemax Maximum permitted overhung load at the input shaft for continuous duty (load N
application point is the middle of the shaft end)
FRacub Cubic overhung load with cubic torque Macub N
H Installation altitude m above
sea level
I0 Current consumption of the motor at M0 A
Imax Maximum permitted motor current (root-mean-square value) A
Ins. cl. Thermal classification of the motor
i Gear unit reduction ratio
IM Gear unit mounting position (international mounting position) M1 to M6
IP.. Degree of protection according to IEC60034‑5
JA Mass moment of inertia of the adapter kgm2
JG Mass moment of inertia of the gear unit kgm2
Jext Mass moment of inertia (external) reduced on motor shaft kgm2
JMot Mass moment of inertia of the motor kgm2
19381212/EN – 03/2015

JL Mass moment of inertia of the load kgm2


k Inertia ratio Jext / JMot
l Length of output shaft mm
M1 – Mn Output torque in time period t1 to tn Nm
M0 Standstill torque (thermal continuous torque at low speeds) Nm

30 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Project planning
Drive and gear unit selection data 5
Designation Meaning Unit
MaDYN Dynamic output torque assumed for the drive in project planning Nm
Maeff Effective torque for component testing calculated in project planning Nm
Macub Effective torque for bearing testing calculated in project planning Nm
Mamax Maximum permitted output torque for continuous duty Nm 5
Mapk Maximum permitted torque for short-time duty Nm
MaEmergOff Maximum permitted emergency stop torque, max. 1000 emergency stops Nm
Math Effective torque for thermal testing calculated in project planning Nm
MB Rated brake torque Nm
Mpk Dynamic limit torque of the servomotor Nm
Meff Effective torque requirement (in relation to the motor) Nm
Mmax Maximum output torque assumed for the drive in project planning Nm
ML Mounting location (UL)
napk Maximum permitted output speed for short-time duty rpm
nepk Maximum permitted input speed for short-time duty rpm
nem Mean input speed rpm
nam Mean output speed rpm
nak Breakpoint speed (output) rpm
nN Rated speed rpm
n1 – nn Output speed in time period t1 to tn rpm
netn_pk Maximum input speed in section rpm
PBr Braking power W
PBr_pk Peak braking power W
PBr_eff Effective braking power W
PBr_tn Braking power in section tn W
S.., ..% cdf Duty type and cyclic duration factor (cdf) or exact load cycle can be entered. s
t1 – tn Time period 1 to n s
tz Cycle time s
TAmb Ambient temperature °C
Usys System voltage, voltage of the supplying inverter V
UBr Operating voltage of the brake V
x Distance between overhung load application point and shaft shoulder mm
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 31


5 Project planning
Drive and gear unit selection data

5.1.1 Determining the application data


It is necessary to have data on the machine to be driven (mass, speed, setting range,
etc.) to project the drive correctly.
This data helps to determine the required power, torque and speed. Refer to the publi-
cation "Drive Engineering – Practical Implementation / Drive Planning" or the
SEW‑EURODRIVE project planning tool SEW Workbench for assistance.

5.1.2 Selecting the correct drive


The appropriate drive can be selected once the power and speed of the drive have
been calculated and with regard to mechanical requirements.

19381212/EN – 03/2015

32 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Project planning
Project planning procedure 5
5.2 Project planning procedure
The following flowcharts show a schematic view of the project planning procedure of a
servo gear unit for a positioning drive in S3 duty cycle.

5.2.1 Project planning procedure: Part 1, servo gear units 5


M max gear unit Mmax # Mapk
n max motor n max # n epk Select gear unit
from project planning

ja

n1 · t1 + ... + nn · tn
nam =
t1 + ... + tn

Gear unit data

3 3
nam # nak no n1 • t1 • M 1 + ... + n n • t n • M n
M a cub = 3
n 1 • t 1 + ... + n n • t n
yes

0.3
n Check gear unit /
8 8
fk = 1 namak 2 check application
n1 • t1 • M 1 + ... + n n • t n • M n
M aeff = 8
n 1 • t 1 + ... + n n • t n
M amax no
M acub #
fK

M aeff # M amax no
yes

yes 1,2 1,2

1,2
n1 • t1 • M1 +...+ nn • tn • Mn
Math =
n1 • t1 +... + nn • tn

* a2
MTHERM = a0 + a1 · nam +
n1,2
am

no
Math # MTHERM

yes

no
MEmergOff # table

yes

9007204389640459
19381212/EN – 03/2015

* For thermal project planning of R, F, K, S, W gear units, please contact


SEW‑EURODRIVE.

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 33


5 Project planning
Project planning procedure

5.2.2 Project planning procedure: Part 2, servo gear units

yes

yes
Coupling operation

no

Check gear unit /


Mmax · 2000
FRmax = · fZ check application
d0

no
x = l/2

yes
FRmax # FRaPk· a no
b + x

yes no
FRmax # FRaPk

yes
c no
FRmax #
f + x

yes Macub· 2000


FRcub = · fZ
d0

no
x = l/2

yes
FRcub #FRamax· a no
b + x

yes
FRcub # FRamax no

yes

Project planning
19381212/EN – 03/2015

finished

9007204389655947

For preloaded drives (toothed belts, flat belts, narrow belts, and pinion / gear rack), the
cubic overhung load (FRcub) equals the maximum overhung load (FRmax).

34 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Project planning
Project planning procedure 5
5.2.3 Project planning procedure: Part 3, servomotors

Determine the
maximum
input torque Me max

M max
M e max =
i×η 5

Preliminary determination
of the motor by means of
the torque Mpk

Determine mass
inertia ratio "k"

k ≤ 15 no

yes

Determine motor torques


for all
travel sections

Determine the
effective motor torque

1 2 2
Meff = × ( M1 × t1 + ... + Mn × tn )
tZ

Determine the
thermal effective speed
n11.5× t1 + ... + nn 1.5× tn
n eff = 1.5
tz

Determine
the operating point

Operating point
below or max. on the
no
thermal characteristic curve
19381212/EN – 03/2015

Meff ≤ MNom

yes

9007204389658635

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 35


5 Project planning
Project planning procedure

5.2.4 Project planning procedure: Part 4, servomotors

yes

Check dynamic
limit torque no
Mmax # Mpk of the motor

yes

Select controller in
selection tables * using
the effective torque Meff
and max. motor torque Mpk

Calculate the
peak braking power
Mpk × nte × ηLoad
PBr _ pk =
9550

Calculate the
mean braking power
PBr _ t1 + ... + PBr _ tn ´ tn
PBr =
tZ

Select braking resistor


in the "assignment table
*
braking resistor – inverter"
using the max. braking
power and the mean
braking power

Select more components,


such as encoder interfaces
and perhaps
fieldbus cards, etc.

End

9007204389661323
19381212/EN – 03/2015

® ®
* MOVIDRIVE system manual, MOVIAXIS system manual

36 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Project planning
Thermal characteristics 5
5.3 Thermal characteristics
5.3.1 Notes on selecting synchronous servomotors
Project planning for a servomotor involves the following tasks for determining the ther-
mal and dynamic load on the motor:
• Calculating the effective operating point for checking the thermal load on the mo- 5
tor.
• Calculating the maximum operating point for determining the motor/inverter com-
bination.
• Determining the inertia ratio Jext/JMot for checking the stability of the speed control.

5.3.2 Procedure

• Determining the maximum speed based on aspects of the inertia ratio


Jext / JMot< 15.
• Maximum required torque Mmax at maximum speed nmax (maximum operating
point).
Mmax < Mdyn_Mot when nmax
Mdyn_Mot corresponds to the maximum torque with the specific motor/inverter com-
bination. This operating point must lie below the characteristic curve for the maxi-
mum torque of the motor/MOVIDRIVE®/MOVIAXIS® motor combination.
• Effective torque demand at the average speed of the application (effective operat-
ing point).
Meff < MN_Mot when nmedium
This operating point must lie below the characteristic curve for continuous torque
to ensure thermal stability of the drive.

5.4 Operating temperatures


5.4.1 Maximum ambient temperature
CMP motors are designed for use in a temperature range between -20 °C and +40 °C.

5.4.2 Higher operating temperatures


CMP servomotors can optionally be used at a maximum ambient temperature of 60°C.
Please contact SEW‑EURODRIVE if the motors are used at higher ambient tempera-
tures. See also chapter Derating for increased ambient temperature (→ 2 38).

INFORMATION
If the motor is operated at higher ambient temperatures, also take account of the
19381212/EN – 03/2015

project planning for the power cable.

5.4.3 Cold storage application


Taking suitable measures, motors can be used for cold storage applications up to
-40 °C. The temperature range from -40 °C to +10 °C is listed on the nameplate.

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 37


5 Project planning
Derating for increased ambient temperature

5.5 Derating for increased ambient temperature


For projecting the CMP synchronous servomotors with permanent-magnet excitation,
the following derating applies in the ambient temperature range +40 °C to + 60 °C:
• The thermal speed/limit torque characteristic curve is re-scaled towards the origin
(minimized). The thermal operating point based on effective torque and thermally
effective speed of the application must be below the re-scaled characteristic curve.

M0
M 0 (Tu)

n0(Tu) n0

4793062795

 145°C − TU 
M0 (TU ) = M 0 x  

 105°C 

 145°C − TU 
n 0 (TU ) = K e x n0 x  

 105°C 

TA Ambient temperature [°C]


M0 Static torque under nominal conditions
M0(TA) Standstill torque at increased temperatures 40 °C < TA < 60 °C
n0 Thermal limit speed under nominal conditions
n0(TA) Thermal limit speed at increased temperatures 40 °C < TA < 60 °C
Ke Encoder factor for resolver = 1; for electronic encoder (e.g. Hiperface® en-
coder) = 0.9

19381212/EN – 03/2015

38 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Project planning
Mechanical and electrical characteristics 5
5.6 Mechanical and electrical characteristics
Design CMP40 / 50 / 63 / 71 / 80 / 100 / 112
Standard Optional
Degree of protection IP65 IP66
5
Thermal class 155 (F) –
Motor protection KTY TF
Connection Adjustable plug con- Radial plug connector (not
nector CMP112), terminal box
(CMP50 to 112)
Shaft end Smooth With key, domed type A
Ambient temperature -20 °C to +40 °C -20 °C to +60 °C
-40 °C to +10 °C
Standard/regulations CE CSA / UL
VDE UL
Noise levels according to Below specified value –
EN 60034
Feedback 2-pole resolver Hiperface® encoder
Brake – BP: CMP71 – 100
BK: CMP40 – 63
BY: CMP.71 – 100, CMP112
Cooling Convection Forced cooling fan for
CMP50 to CMP112
Vibration class "B" to EN 60034-14
Number of poles CMP40 – 63: 6 –
CMP.71 – 100: 10
CMP112: 6
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 39


5 Project planning
Mechanical and electrical characteristics

5.6.1 Speed classes, rated speeds


Speed classes (rated speeds) of synchronous servomotors:
• 2000 rpm
• 3000 rpm
• 4500 rpm
• 6000 rpm
As synchronous servomotors operate as controlled drives, it is necessary to consider
the inertia ratio between the load and the motor. This ratio is a decisive factor in deter-
mining the quality of closed-loop control. The inertia ratio should not exceed the val-
ues listed in the table below.
Reduction of the inertia ratio using the motor speed or the selected gear unit reduction
ratio offers hardly any advantage with respect to closed-loop control starting at the val-
ue Jext / JMot < 8.
Backlash and elasticity negatively influence the possible dynamic response of the
driveline and must be kept to a minimum.
As a result, the maximum speed should be selected such that the following criteria are
met:

Driveline Control characteristics Inertia ratio Jext/ / JMot


Forged gear rack, re- Low backlash and low elasticity Jext / JMot < 15
duced backlash gear unit drive
Toothed belt, reduced Common servo applications Jext / JMot < 15
backlash gear unit
Toothed belt, standard Standard applications, cou- Jext / JMot < 10
gear unit plings with torque buffer (elas-
ticity)

19381212/EN – 03/2015

40 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Project planning
Mechanical and electrical characteristics 5
5.6.2 Degree of protection to EN 60034 (IEC 60034‑5)
Synchronous servomotors are supplied with IP65 degree of protection as standard.

IP 1st digit 2nd digit


Touch guard Protection against for- Protection against wa-
eign objects ter 5
0 No protection No protection No protection
1 Protected against access Protection against solid Protection against drip-
to hazardous parts with foreign objects Ø 50 mm ping water
the back of your hand and larger
2 Protected against access Protection against solid Protection against drip-
to hazardous parts with a foreign objects Ø 12 mm ping water when tilted up
finger and larger to 15°
3 Protected against access Protection against solid Protection against spray-
to hazardous parts with a foreign objects Ø 2.5 mm ing water
tool and larger
4 Protected against access Protection against solid Protection against splash-
to hazardous parts with a foreign objects Ø 1 mm ing water
wire and larger
5 Dust-proof Protection against water
jets
6 Dust-proof Protection against power-
ful water jets
7 – – Protection against tempo-
rary immersion in water
8 – – Protection against perma-
nent immersion in water
9 – – Protection against water
penetration from any di-
rection even under in-
creased pressure against
the housing
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 41


5 Project planning
Mechanical and electrical characteristics

5.6.3 Applications

High accelerations
The rotor of the CMP synchronous servomotor is designed to be low-inertia. These
motors are the optimum choice in very dynamic applications. For high accelerations
and accelerations in the millisecond range, the synchronous servomotor is usually the
technically and economically best solution.

Additional flywheel mass


The rotor of the CMPZ synchronous servomotor is equipped with an additional fly-
wheel mass. This additional flywheel mass allows for handling large external masses.

Cogging
The motors produce small torque ripple due to the servo drive design. This torque rip-
ple is corrected by the inverter.

19381212/EN – 03/2015

42 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Project planning
Overhung and axial loads 5
5.7 Overhung and axial loads
The following overhung loads are determined by subjecting the shaft to a load with the
rated torque.
The permitted overhung loads FR at point x are determined via the following diagrams.
"x" is the distance between the shaft shoulder and the force application (→ 2 44).
5
The diagrams are based on the following nominal bearing service life:

Motor type Nominal bearing service life


CMP40 L10h = 25000 h
CMP50 L10h = 25000 h
CMP63 L10h = 20000 h
CMP.71 L10h = 25000 h
CMP.80 L10h = 25000 h
CMP.100 L10h = 25000 h
CMP112 L10h = 25000 h

5.7.1 Ball bearing types used (standard)


The following table shows approved ball bearing types:

Motor type A-side bearing B-side bearing


CMP40 6002-2Z-C3 6001-2Z-C3
CMP50 6004-2Z-C3 6001-2Z-C3
CMP63 6005-2Z-C3 6003-2Z-C3
CMP.71 6206-2Z-J-C3 6202-2Z-J-C3
CMP.80 6307-2Z-J-C3 6304-2Z-J-C3
CMP100 6309-2Z-J-C3 6304-2Z-J-C3
CMPZ100, CMP100 /BP 6309-2Z-J-C3 6205-2Z-J-C3
CMP112 6311-2Z-C3 6207-2Z-C3
The grease fill and the bearing sealing can vary depending on the operational environ-
ment.
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 43


5 Project planning
Overhung and axial loads

5.7.2 Permitted overhung and axial loads for x = l / 2 (shaft center)

4795970187

CMP40 – 63

Motor type FR max in N Mean speed1) in rpm


FA in N 1500 3000 4500 6000
CMP40S FR max 330 260 225 205
FA 109 86 74 68
CMP40M FR max 350 280 245 220
FA 116 92 81 73
CMP50S FR max 475 315 250 200
FA 157 104 83 66
CMP50M FR max 510 355 275 220
FA 168 117 91 73
CMP50L FR max 550 370 280 225
FA 182 122 92 74
CMP63S FR max 680 460 360 290
FA 224 152 119 96
CMP63M FR max 750 500 380 300
FA 248 165 125 99
CMP63L FR max 830 560 445 360
FA 274 185 147 119
1) The mean speed must be determined, for example, from the travel diagram. 19381212/EN – 03/2015

44 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Project planning
Overhung and axial loads 5
CMP.71 – CMP.100, CMP112

Motor type FR max in N Mean speed1) in rpm


FA in N 2000 3000 4500 6000
CMP.71S FR max 953 832 724 636
FA 318 277 240 212 5
CMP.71M FR max 1018 888 747 659
FA 340 296 250 219
CMP.71L FR max 1101 928 777 681
FA 367 309 258 227
CMP.80S FR max 1666 1454 1270 1132
FA 555 485 423 377
CMP.80M FR max 1782 1555 1325 1169
FA 594 518 442 390
CMP.80L FR max 1928 1635 1372 1208
FA 643 544 457 402
CMP.100S FR max 2708 2364 2064 –
FA 903 788 688 –
CMP.100M FR max 2882 2515 2195 –
FA 961 838 732 –
CMP.100L FR max 3099 2694 2278 –
FA 1033 897 759 –
CMP112S FR max 3791 3308 2886 –
FA 1264 1103 962 –
CMP112M FR max 3953 3448 3008 –
FA 1318 1149 1003 –
CMP112L FR max 4102 3456 2898 –
FA 1367 1152 966 –
CMP112H FR max 4118 3465 2900 –
FA 1373 1155 967 –
CMP112E FR max 4126 3467 2896 –
FA 1376 1156 966 –
1) The mean speed must be determined, for example, from the travel diagram.
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 45


5 Project planning
Overhung and axial loads

Permitted overhung load for CMP40S


400
n = 1500 min-1
350

300
n = 4500 min-1
250 n = 3000 min-1
FR [N]

200
n = 6000 min-1
150

100

50

0
0 5 10 15 20 25
X [mm]
9007204050713867

Permitted overhung load for CMP40M


400
n = 1500 min-1
350

300 n = 3000 min-1

n = 4500 min-1
250
FR [N]

200 n = 6000 min-1

150

100

50

0
0 5 10 15 20 25
X [mm]
9007204050716555
19381212/EN – 03/2015

46 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Project planning
Overhung and axial loads 5
Permitted overhung load for CMP50S
600

n = 1500 min-1
500

400 5
n = 3000 min-1
FR [N]

300
n = 4500 min-1
n = 6000 min-1
200

100

0
0 5 10 15 20 25
X [mm]
9007204050719243

Permitted overhung load for CMP50M


600
n = 1500 min-1
500

400 n = 3000 min-1


FR [N]

300 n = 4500 min-1

n = 6000 min-1
200

100

0
0 5 10 15 20 25
X [mm]
9007204050721931
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 47


5 Project planning
Overhung and axial loads

Permitted overhung load for CMP50L


600
n = 1500 min-1
500

400
FR [N] n = 3000 min-1

300 n = 4500 min-1

n = 6000 min-1
200

100

0
0 5 10 15 20 25
X [mm]
9007204050724619

Permitted overhung load for CMP63S


800
n = 1500 min-1
700

600

500 n = 3000 min-1


FR [N]

400 n = 4500 min-1


n = 6000 min-1
300

200

100

0
0 5 10 15 20 25 30 35
X [mm]
9007204050727307
19381212/EN – 03/2015

48 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Project planning
Overhung and axial loads 5
Permitted overhung load for CMP63M
1000

900

800 n = 1500 min-1

700 5
600
FR [N]

n = 3000 min-1
500
n = 4500 min-1
400
n = 6000 min-1
300

200

100

0
0 5 10 15 20 25 30 35
X [mm]
9007204050729995

Permitted overhung load for CMP63L


1000

900 n = 1500 min-1

800

700

600 n = 3000 min-1


FR [N]

500 n = 4500 min-1

400 n = 6000 min-1

300

200

100

0
0 5 10 15 20 25 30 35
X [mm]
9007204050732683
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 49


5 Project planning
Overhung and axial loads

Permitted overhung load for CMP.71S


1300

1200

n = 2000 min-1
1100

1000

n = 3000 min-1
900
FR [N]

800
n = 4500 min-1
n = 6000 min-1
700

600

500

400
0 10 20 30 40 50
X [mm]
9007204050735371

Permitted overhung load for CMP.71M


1300

1200

n = 2000 min-1
1100

1000

n = 3000 min-1
900
FR [N]

800
n = 4500 min-1

700
n = 6000 min-1
600
19381212/EN – 03/2015

500

400
0 10 20 30 40 50
X [mm]
9007204050738059

50 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Project planning
Overhung and axial loads 5
Permitted overhung load for CMP.71L
1300

1200
n = 2000 min-1
1100 5

1000
n = 3000 min-1

900
FR [N]

n = 4500 min-1
800

n = 6000 min-1
700

600

500

400
0 10 20 30 40 50
X [mm]
9007204050740747

Permitted overhung load for CMP.80S


2300

2100

1900
n = 2000 min-1

1700
FR [N]

n = 3000 min-1
1500

n = 4500 min-1
1300
n = 6000 min-1

1100
19381212/EN – 03/2015

900
0 10 20 30 40 50 60
X [mm]
9007204050743435

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 51


5 Project planning
Overhung and axial loads

Permitted overhung load for CMP.80M


2300

2100

n = 2000 min-1

1900

1700
n = 3000 min-1
FR [N]

1500
n = 4500 min-1

1300
n = 6000 min-1

1100

900
0 10 20 30 40 50 60
X [mm]
9007204050746123

Permitted overhung load for CMP.80L


2300

2100
n = 2000 min-1

1900

n = 3000 min-1
1700
FR [N]

1500
n = 4500 min-1

1300
n = 6000 min-1

1100

900
19381212/EN – 03/2015

0 10 20 30 40 50 60
X [mm]
9007204050748811

52 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Project planning
Overhung and axial loads 5
Permitted overhung load for CMP.100S
3300

3100
n = 2000 min-1
2900
5
2700
n = 3000 min-1
2500
FR [N]

2300
n = 4500 min-1
2100

1900

1700

1500

1300

1100
0 10 20 30 40 50 60
X [mm]
9007204050751499

Permitted overhung load for CMP.100M


3300

3100
n = 2000 min-1
2900

2700
n = 3000 min-1
2500
FR [N]

2300
n = 4500 min-1
2100

1900

1700

1500

1300
19381212/EN – 03/2015

1100
0 10 20 30 40 50 60
X [mm]
9007204050754187

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 53


5 Project planning
Overhung and axial loads

Permitted overhung load for CMP.100L


3500

3300 n = 2000 min-1

3100

2900
n = 3000 min-1
2700

2500
n = 4500 min-1
FR [N]

2300

2100

1900

1700

1500

1300

1100
0 10 20 30 40 50 60
X [mm]
9007204050756875

Permitted overhung load for CMP112S


4500

n = 2000 min-1
4000

n = 3000 min-1
3500
FR [N]

n = 4500 min-1

3000

2500
19381212/EN – 03/2015

2000
0 10 20 30 40 50 60 70 80 90
X [mm]
9007208142963083

54 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Project planning
Overhung and axial loads 5
Permitted overhung load for CMP112M
5000

4500
n = 2000 min-1
5
4000
FR [N]

n = 3000 min-1

3500
n = 4500 min-1

3000

2500

2000
0 10 20 30 40 50 60 70 80 90
X [mm]
9007208142961163

Permitted overhung load for CMP112L


5000

4500
n = 2000 min-1

4000
FR [N]

n = 3000 min-1
3500
n = 4500 min-1

3000

2500

2000
0 10 20 30 40 50 60 70 80 90
X [mm]
9007208142959243
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 55


5 Project planning
Overhung and axial loads

Permitted overhung load for CMP112H


5000

4500
n = 2000 min-1

4000
FR [N]

n = 3000 min-1
3500

n = 4500 min-1
3000

2500

2000
0 10 20 30 40 50 60 70 80 90
X [mm]
9007208142957323

Permitted overhung load for CMP112E


5000

4500
n = 2000 min-1

4000
FR [N]

n = 3000 min-1
3500

n = 4500 min-1
3000

2500

2000
0 10 20 30 40 50 60 70 80 90
X [mm]
9007208142965003
19381212/EN – 03/2015

56 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Project planning
Project planning example 5
5.8 Project planning example
In the example, a gantry with synchronous servomotors is determined.
The symbols used in the equations are explained in chapter Drive and gear unit selec-
tion data (→ 2 30).

5
5.8.1 Selecting the x-axis (travel axis)

Gantry with servo drives – travel axis

Reference data:
• Total moved mass: mL = 50 kg
• Diameter of the belt pulley: d0 = 75 mm
• Friction coefficient of the axis: µ = 0.01
• Travel speed: vmax = 2 m/s
• Maximum acceleration/deceleration: amax = 10 m/s2
• Cycle time: tz = 3 s
• Pause time: tp = 1.8 s
• Load efficiency: ηL = 0.9
• Mounting position of the gear unit: IM = M1
For the drive, a PC.C gear unit is designed to be mounted directly to a CMP servomo-
tor.
The overhung load is to act on the shaft center.
Power is transmitted via a belt pulley.
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 57


5 Project planning
Project planning example

Travel sections
Diagram: Travel sections 1 to 4
v
[m/s]

t [s]

1 2 3 4

9007204051282699

Acceleration time in travel section 1, deceleration time in travel section 3

v 2 m/s
t1 = t3 = amax = = 0.2 s
max 10 m/s 2

Travel time for constant travel in travel section 2

t2 = t z - t p - t1 - t3
t2 = 3 s - 1.8 s - 0.2 s - 0.2 s
t2 = 0. 8 s

Mstat for all travel sections

d0
(m· g· µ)·
M stat = 2
ηL
m 0. 075m
50kg · 9. 81 2
· 0. 01 ·
s 2
M stat =
0.99
M stat = 0. 2043 Nm
9007204051559563

Mdyn during acceleration in travel section 1

d0
( m · a) ·
M dyn = 2
ηL
m 0. 075m
19381212/EN – 03/2015

50kg · 10 ·
s2 2
M dyn =
0. 9
M dyn = 20. 83 Nm
9007204051562251

58 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Project planning
Project planning example 5
Mdyn during deceleration in travel section 3

d0
M dyn = m · a · ·η
2 L
m 0. 075m
M dyn = 50kg · ( - 10 2 ) · · 0. 9
s 2 5
M dyn = - 16.8875Nm

Mmax during acceleration in travel section 1

M max = M stat + M dyn1


M max = 0. 2043 Nm +20. 8333 Nm
M max = 21. 04 Nm
9007204051567627

Mmax during deceleration in travel section 3

M max = M stat + M dyn 3


M max = 0. 2043 Nm +( - 16. 87 Nm )
M max = - 16. 6657 Nm

Output speed

vmax
na max = · 60
d0 · π
m
2
na max = s · 60
0. 075m · π
1
na max = 509. 295
min
4796832011

Gear ratio including 10% motor speed reserve


nN = 4500 rpm is an assumption

nN · 0.9
i=
na max
1
4500 · 0.9
i= min
1
19381212/EN – 03/2015

509. 295
min
i = 7.95
4796834699

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 59


5 Project planning
Project planning example

Maximum input speed

nmax = na max · i
1
nmax = 509. 295 · 7
min
1
nmax = 3565. 065
min

Servo gear unit project planning


The gear unit is selected on the basis of the table below
cT FRa FRapk
Mamax Mapk MaEmergOff nak JG PSC PSC PSC
i Nm Nm Nm rpm 10-4kgm2 Nm/" N N
PSC221 3 29 40 60 1500 0,172 3.46 1170 2000
5 34 42 63 720 0.0578 3.44 1390 2000
1
7 32 39 59 800 0.03 3.28 1550 2000
10 30 37 56 700 0.0144 2.92 1750 2000

M1;M3;M5-6 M2 M4 ϕ
nepk η a0 a1 a2 a0 a1 a2 a0 a1 a2
i rpm % '
PSC221 3 7000 99 101.00 -0,093 0 106.00 -0,104 0 109.00 -0,110 0 10
5 7000 99 160.00 -0,181 0 163.00 -0,190 0 167.00 -0,200 0 10
1
7 7000 99 186.00 -0,257 0 187.00 -0,264 0 186.00 -0,267 0 10
10 7000 99 158.00 -0,178 0 161.00 -0,184 0 164.00 -0,194 0 10

Selection condition:
Mmax ≤ Mapk
21.04 Nm ≤ 39 Nm
nmax ≤ nepk
3565 rpm ≤ 7000 rpm
Condition is fulfilled.

Mean output speed

n1 · t1 +... +... nn · tn
nam =
t1 +... +...tn
1 1
509. 295 509. 295
min · 0. 2 s + 509. 295 1 · 0. 8 s + min · 0. 2 s
nam = 2 min 2
0. 2 s + 0. 8 s + 0 . 2 s +1.8 s
1
nam =169. 765
min
9007204051585419
19381212/EN – 03/2015

Selection condition:
nam ≤ nak
169.765 rpm ≤ 809 rpm
Condition is fulfilled.

60 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Project planning
Project planning example 5
Effective torque of servo gear unit
8 8
n1 · t1 · M 1 + ... + ...nn · tn · M n
M aeff = 8
n1 · t1 + ... + nn · tn
1 1
509. 295 506. 295
min · 0. 2 s · 21. 04 Nm 8 + 509. 295 1 · 0. 8s · 0. 2043 Nm 8 + min · 0. 2 s · - 16. 67 Nm 8
2 min 2
M aeff =8
0. 2 s · 254. 64
1
+ 0. 8 s · 509. 295
1
+ 0. 2 s · 254. 64
1 5
min min min
M aeff = 16. 065 Nm

9007204051589771

Selection condition:
Maeff ≤ Mamax
16.065 Nm ≤ 32 Nm
Condition is fulfilled.

Thermal torque of servo gear unit


1.2 1.2
n1 · t1 · M 1 +... +...nn · tn · M n
Math =1.2
n1 · t1 +... + nn · tn
1 1
509. 295 506. 295
min · 0. 2 s · 21. 04 Nm 1.2+509. 295 1 · 0. 8 s · 0. 2043 Nm 1.2+ min · 0. 2 s · - 16. 67 Nm 1.2
Math =1.2 2 min 2
1 1 1
0. 2 s · 254. 64 +0. 8 s · 509. 295 +0. 2 s · 254. 64
min min min
Math = 5.009 Nm

9007204051594123

Thermal factors for mounting position M1


a0 = 186
a1 = -0.257
a3 = 0

a2
M Therm = a0 + a1 · nam +
n1am.2
1 0
M Therm = 186 + (- 0. 257 · 169. 765 )+
min 169. 7651, 2
M Therm = 142. 37 Nm

Selection condition:
Math ≤ MTherm
5.035 Nm ≤ 142.37 Nm
Condition is fulfilled.
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 61


5 Project planning
Project planning example

Overhung load calculation

M max
FR max = · fz
d0
2
21. 04 Nm
FR max = · 2. 5
0. 075 m
2
FR max = 1402 N
4796859147

The force application point is the center of the output shaft.


Selection condition:
FRmax ≤ FRaPk
1402 N ≤ 2000 N
Condition is fulfilled.

Calculation of the overhung load on the shaft end


3 3
n1 · t1 · M 1 +... +... nn · tn · M n
M akub = 3
n1 · t1 +... + nn · tn
1 1
509. 295 3 506 . 295
min · 0. 2s · 21. 04N m 3 + 509. 295 1 · 0. 8s · 0. 2043 Nm + min · 0. 2 s · - 16. 67 Nm 3
M akub =3 2 min 2
1 1 1
0. 2 s · 254. 64 +0. 8 s · 509. 295 +0. 2 s · 254. 64
min min min
M akub =11.172 Nm

M akub
FRkub = · fz
d0
2
11.12 Nm
FRkub = · 2. 5
0. 075m
2
FRkub = 744. 8 N

9007204051604491

Selection condition:
FRkub ≤ FRmax
744.8 N ≤ 1402 N
Condition is fulfilled.
19381212/EN – 03/2015

62 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Project planning
Project planning example 5
Load torques in travel sections 1 to 3

Travel section 1

M dyn1
M e max 1 =
i · ηG
21. 04 Nm 5
M e max 1 =
7 · 0 . 99
M e max 1 = 3. 036 Nm

Travel section 2

M stat
M e max 2 =
i · ηG
0. 2043 Nm
M e max 2 =
7 · 0. 99
M e max 2 = 0. 0294 Nm

Travel section 3

M dyn 3 · ηG
M e max 3 =
i
- 16. 67 Nm · 0. 99
M e max 3 =
7
M e max 3 = - 2. 357 Nm
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 63


5 Project planning
Project planning example

5.8.2 Motor selection


Preliminary determination of motor using torque Mpk.

nN Motor M0 I0 Mpk Imax M0VR I0VR Jmot Jbmot MB1 MB2 L1 R1 Vp0 cold
2
rpm Nm A Nm A Nm A kgcm Nm mH Ω V
4500 CMP40S 0.5 1.2 1.9 6.1 - - 0.1 0.13 0.85 -- 23 11.94 27.5
CMP40M 0.8 0.95 3.8 6.0 - – 0.15 0.18 0.95 -- 45.5 19.92 56
CMP50S 1.3 1.32 5.2 7.0 1.7 1.7 0.42 0.48 3.1 4.3 37 11.6 62
CMP50M 2.4 2.3 10.3 13.1 3.5 3.35 0.67 0.73 4.3 3.1 20.5 5.29 66
CMP50L 3.3 3.15 15.4 19.5 4.8 4.6 0.92 0.99 4.3 3.1 14.6 3.56 68
CMP63S 2.9 3.05 11.1 18.3 4 4.2 1.15 1.49 7 9.3 18.3 3.34 64
CMP63M 5.3 5.4 21.4 32.4 7.5 7.6 1.92 2.26 9.3 7 9.8 1.49 67
CMP63L 7.1 6.9 30.4 41.4 10.3 10 2.69 3.03 9.3 7 7.2 1.07 71
Selected motor:
CMP63M
Mpk = 21.4 Nm
Jmot = 1.92 × 10-4 kgm2

5.8.3 Determining the inertia ratio "k"


2
vmax
J ext = 91. 2 · m · ( ) +J
nmax
G

2
m
J ext = 91. 2 · 50kg ·
( 2 )
s + 0 . 03 · 10
2
-4
kgm 2
(3565. 065
min )
1

J ext =14. 38125 · 10- 4 kgm 2

Jext is thus in relation to the motor shaft.

J ext
k=
J Motor
14. 38125 · 10- 4 kgm 2
k=
1. 92 · 10- 4 kgm 2
k = 7. 49

Selection condition:
k ≤ 15
19381212/EN – 03/2015

7.49 ≤ 15
Condition is fulfilled.

64 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Project planning
Project planning example 5
5.8.4 Intrinsic acceleration or deceleration of motor in sections 1 and 3
nmax
M Eigen = ( J G + J Mot ) ·
9. 55 · t
1
3565. 065
M Eigen = (0. 03 · 10- 4 kgm 2 + 1. 92 · -10- 44 kgm 2) · min
9. 55 · 0. 2 s 5
M Eigen = 0. 3639 Nm

5.8.5 Maximum motor torques in sections 1 and 3

Travel section 1
M t1 = M e max 1 + M Eigen
M t1 = 3. 036 Nm + 0. 3639 Nm
M t1 = 3. 3999 Nm

Travel section 2
M t 3 = M e max 3 + M Eigen
M t 3 = - 2. 357 Nm + 0. 3639 Nm
M t 3 = - 1. 9931Nm

5.8.6 Effective motor torque


1
M12 · t1 + ... + M n2 · tn )
tz (
M eff =

2 2 2
( 3. 399 Nm ) · 0. 2 s + ( 0. 0294 Nm ) · 0. 8 s + ( - 1. 9931 Nm) · 0. 2 s
M eff =
3s
Meff = 1. 0174 Nm

5.8.7 Thermal effective motor speed

n11.5 · t1 + ... + n1n.5 · tn


neff = 1.5
tz
1. 5 1. 5
1 1
3565. 065 1. 5 3565. 065
min 1 min
· 0. 2 s + 3565. 065 · 0.8s + · 0. 2 s
1. 5 2 min 2
neff = 3s

1
neff = 1646. 3
19381212/EN – 03/2015

min

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 65


5 Project planning
Project planning example

5.8.8 Determining the dynamic and thermal motor operating points


• The thermal operating point must be below or exactly on the thermal limit charac-
teristic curve:
Meff ≤ MNom
• The dynamic limit torque must be checked:
Mmax Mot ≤ Mpk

360V M S1
20
400V M S1 /VR

460V M S1, BK

15 500V

DC 750V
M [Nm]

10

5
Mt1

Meff
0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

Key:
M S1 M S1 thermal (derating)
DC 750 V controlled on DC 750 V constant
500 V 500 V line voltage, non-controlled
460 V 460 V line voltage, non-controlled
400 V 400 V line voltage, non-controlled
360 V 360 V line voltage, non-controlled
Definition:
• M = Maximum dynamic torque for a maximum line voltage on the inverter of 360 V,
400 V, 460 V or 500 V
• M S1 (derating) = thermal limit characteristic curve in S1 – 100% operation
19381212/EN – 03/2015

66 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Project planning
Project planning example 5
5.8.9 Inverter assignment
Refer to the inverter assignments of CMP servomotors to MOVIDRIVE® and
MOVIAXIS® in chapter Technical data of the motors (→ 2 71).

5.8.10 Calculating the braking resistor


5
The selection of the braking resistor depends, among other factors, on which braking
resistor may be connected to the respective inverter.
If you use a MOVIDRIVE® inverter or MOVIAXIS® servo inverter, refer to the respec-
tive system manual for detailed information.
You can also determine the corresponding braking resistor using the SEW Work-
bench.

Peak braking power in travel section 3

M tn · ntn · η Last
PBr _ pk =
9550
1
1. 9931Nm · 3565 · 0. 9
PBr _ pk = min
9550
PBr _ pk = 0. 6696kW

Mean braking power in travel section 3

M tn · ntn · η Last
PBr =
9550
1
3565
1. 9931Nm · min · 0. 9
PBr = 2
9550
PBr = 0. 3348kW
4796909195

Effective braking power

PBr ⋅ t3
PBr _ eff =
tz
0.3348kW ⋅ 0.2s
PBr _ eff =
3s
PBr _ eff = 0.0223kW
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 67


5 Project planning
Operation on inverter

5.9 Operation on inverter


The following products are available from SEW‑EURODRIVE for operating the syn-
chronous servomotors on inverters:
• MOVIDRIVE® MDX60B/61B drive inverter
• MOVIAXIS® MX multi-axis servo inverter
MOVIDRIVE ® MOVIAXIS® MX
MDX60/61 B

4800297995
19381212/EN – 03/2015

68 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Project planning
Operation on inverter 5
5.9.1 Product characteristics
The following table lists the most important product characteristics for the various in-
verter series. You can choose the inverter series matching your application based on
these product characteristics.

Product characteristics MOVIDRIVE® MDX60/61B MOVIAXIS® MX


5
Voltage range 3 × AC 380 – 500 V 3 × AC 380 – 500 V
3 × 200 – 240 V AC (limited power
range)
Input power range 0.55 – 160 kW 10 – 75 kW
Rated current range of axis mod- 4 – 250 A 2 – 133 A
ules
Overload capacity 150% IN1) briefly and 125% IN per- 250% for max. 1 second
manently during operation without
overload.
4Q capable Yes, with integrated brake chopper as standard.
Integrated line filter According to limit value class A for Yes, according to limit class A.
sizes 0, 1, and 2
TF input Yes
Control modes V/f or voltage-controlled flux vector Current-controlled flux vector con-
control (VFC), with speed feed- trol
back speed control and current-
controlled flux vector control
(CFC).
System resolution 4096 65536
Speed feedback Option Integrated in basic unit
Integrated positioning and se- Standard
quence control system
Serial interfaces System bus (SBus) CAN based system bus SBus, op-
tional EtherCAT® compatible sys-
RS-485
tem bus SBusplus
Fieldbus interfaces Optional PROFIBUS-DP, INTER- Optional PROFIBUS-DP,
BUS, INTERBUS FOC, CANopen, EtherCAT®
DeviceNetTM, Ethernet
Technology options Input/output card Synchronous operation, electronic
gear, touch probe, event control,
Synchronous operation
electronic cam, virtual encoder,
Absolute encoder card single-axis positioning
IEC-61131 control
Max. speed 6000 rpm 10000 rpm
19381212/EN – 03/2015

STO – Safe Torque Off Yes Option


Approvals UL and cUL approval, C-tick
1) Only for MOVIDRIVE® MDX60/61B: The temporary overload capacity of size 0 units (0005 to 0014) is 200% IN

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 69


5 Project planning
Maximum speeds of CMP and CMPZ motors

5.10 Maximum speeds of CMP and CMPZ motors


The following maximum speeds, which are permitted mechanically, apply to the mo-
tors:

Motor type Maximum speed in rpm


CMP40 – 63/BK
CMP40 – 80 7200
CMPZ71 – 80
CMP100, CMPZ100 5400
CMP112 5200
CMP40 – 71 /BP 6000
CMP80 /BP 5500
CMP100 /BP 5400
CMP112 /BY 4500
CMPZ71 /BY 6000
CMPZ80 – 100 /BY 4500

19381212/EN – 03/2015

70 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Key to the technical data 6
6 Technical data of the motors
6.1 Key to the technical data
nN Rated speed
M0 Standstill torque (thermal continuous torque at low speeds)
I0 Standstill current 6
Mpk Dynamic limit torque
Imax Maximum permitted motor current
M0VR Standstill torque with forced cooling fan
I0VR Standstill current with forced cooling fan
Jmot Mass moment of inertia of the motor
Jbmot Mass moment of inertia of the brakemotor
M2, 20 °C Nominal torque for slipping brake disk (relative speed between brake disk
and friction surface: 1 m/s) at 20 °C
M4,120 °C Minimum holding torque at 120 °C
Wmax1 Maximum permitted braking work per braking operation
Wmax2 Maximum permitted braking work per braking operation with optional
braking torque
L1 Inductance between connection phase and star point
R1 Resistance between connection phase and star point
Vp0 cold Internal voltage at 1000 rpm
mmot Mass of the motor
mbmot Mass of the brakemotor
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 71


6 Technical data of the motors
CMP40 to CMP112, 400 V system voltage

6.2 CMP40 to CMP112, 400 V system voltage


nN Motor M0 I0 Mpk Imax M0VR I0VR m Jmot
rpm Nm A Nm A Nm A kg 10-4kgm2
2000 CMP71S 6.4 3.4 19.2 17 8.7 4.6 7.0 3.1
CMP71M 9.4 5 30.8 26 13.7 7.3 8.4 4.2
CMP71L 13.1 6.3 46.9 39 21 10.1 11.4 6.3
CMP80S 13.4 6.9 42.1 33 18.5 9.5 12.8 9.0
CMP80M 18.7 9.3 62.6 48 27 13.4 16.5 12.1
CMP80L 27.5 12.5 107 72 44 20 21.4 18.3
CMP100S 25.5 13.3 68.3 49 36 18.8 19.8 20.3
CMP100M 31 14.7 108 69 47 22.3 24.8 27.2
CMP100L 47 21.8 179 113 70 32.5 34.6 40.9
CMP112S 30 14.3 88 51 43 21 38.4 74.0
CMP112M 45 21 136 74 68 32 46.2 103
CMP112L 69 33 225 124 109 52 62.56 163
CMP112H 83 38 270 148 123 57 70.43 193
CMP112E 95 44.5 320 175 150 71 78.2 222
3000 CMP40S 0.5 1.2 1.9 6.1 – – 1.3 0.10
CMP40M 0.8 0.95 3.8 6.0 – – 1.6 0.15
CMP50S 1.3 0.96 5.2 5.1 1.7 1.25 2.3 0.42
CMP50M 2.4 1.68 10.3 9.6 3.5 2.45 3.3 0.67
CMP50L 3.3 2.2 15.4 13.6 4.8 3.2 4.1 0.92
CMP63S 2.9 2.15 11.1 12.9 4 3 4.0 1.2
CMP63M 5.3 3.6 21.4 21.6 7.5 5.1 5.7 1.9
CMP63L 7.1 4.95 30.4 29.7 10.3 7.2 7.5 2.7
CMP71S 6.4 4.9 19.2 25 8.7 6.7 7.0 3.1
CMP71M 9.4 7.5 30.8 39 13.7 10.9 8.4 4.2
CMP71L 13.1 9.4 46.9 58 21 15.1 11.4 6.3
CMP80S 13.4 10 42.1 47 18.5 13.8 12.8 9.0
CMP80M 18.7 13.4 62.6 69 27 19.3 16.5 12.1
CMP80L 27.5 18.7 107 107 44 30 21.4 18.3
CMP100S 25.5 19.6 68.3 73 36 27.5 19.8 20.3
CMP100M 31 21.8 108 102 47 33 24.8 27.2
CMP100L 47 32.3 179 167 70 48 34.6 40.9
CMP112S 30 21 88 74 43 30.5 38.4 74.0
CMP112M 45 32 136 113 68 49 46.2 103
CMP112L 69 49 225 183 109 77 62.56 163
CMP112H 83 57 270 220 123 84 70.43 193
CMP112E 95 65 320 255 150 104 78.2 222
19381212/EN – 03/2015

72 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
CMP40 to CMP112, 400 V system voltage 6
nN Motor M0 I0 Mpk Imax M0VR I0VR m Jmot
rpm Nm A Nm A Nm A kg 10-4kgm2
4500 CMP40S 0.5 1.2 1.9 6.1 – – 1.3 0.10
CMP40M 0.8 0.95 3.8 6.0 – – 1.6 0.15
CMP50S 1.3 1.32 5.2 7.0 1.7 1.7 2.3 0.42
CMP50M 2.4 2.3 10.3 13.1 3.5 3.35 3.3 0.67
CMP50L 3.3 3.15 15.4 19.5 4.8 4.6 4.1 0.92
CMP63S 2.9 3.05 11.1 18.3 4 4.2 4.0 1.2 6
CMP63M 5.3 5.4 21.4 32.4 7.5 7.6 5.7 1.9
CMP63L 7.1 6.9 30.4 41.4 10.3 10 7.5 2.7
CMP71S 6.4 7.3 19.2 38 8.7 9.9 7.0 3.1
CMP71M 9.4 10.9 30.8 57 13.7 15.9 8.4 4.2
CMP71L 13.1 14.1 46.9 87 21 22.5 11.4 6.3
CMP80S 13.4 15.3 42.1 73 18.5 21 12.8 9.0
CMP80M 18.7 20.1 62.6 103 27 29 16.5 12.1
CMP80L 27.5 27.8 107 159 44 44.5 21.4 18.3
CMP100S 25.5 30 68.3 111 36 42.5 19.8 20.3
CMP100M 31 33.1 108 154 47 50 24.8 27.2
CMP100L 47 48.4 179 251 70 72 34.6 40.9
CMP112S 30 31.5 88 112 43 45.5 38.4 74.0
CMP112M 45 47 136 168 68 72 46.2 103
CMP112L 69 73 225 275 107 114 62.56 163
CMP112H 83 86 270 335 123 128 70.43 193
CMP112E 95 98 320 385 150 156 78.2 222
6000 CMP40S 0.5 1.2 1.9 6.1 – – 1.3 0.10
CMP40M 0.8 1.1 3.8 6.9 – – 1.6 0.15
CMP50S 1.3 1.7 5.2 9.0 1.7 2.2 2.3 0.42
CMP50M 2.4 3 10.3 17.1 3.5 4.4 3.3 0.67
CMP50L 3.3 4.2 15.4 26 4.8 6.1 4.1 0.92
CMP63S 2.9 3.9 11.1 23.4 4 5.4 4.0 1.2
CMP63M 5.3 6.9 21.4 41.4 7.5 9.8 5.7 1.9
CMP63L 7.1 9.3 30.4 55.8 10.3 13.5 7.5 2.7
CMP71S 6.4 9.6 19.2 50 8.7 13.1 7.0 3.1
CMP71M 9.4 14.7 30.8 76 13.7 21.5 8.4 4.2
CMP71L 13.1 18.8 46.9 115 21 30 11.4 6.3
CMP80S 13.4 20 42.1 95 18.5 27.5 12.8 9.0
CMP80M 18.7 26.4 62.6 135 27 38 16.5 12.1
CMP80L 27.5 37.6 107 215 44 60 21.4 18.3
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 73


6 Technical data of the motors
CMP40 to 63 with BK brake, 400 V system voltage

6.3 CMP40 to 63 with BK brake, 400 V system voltage


nN Motor L1 R1 Vp0 cold mbmot Jbmot M4,120 °C
rpm mH Ω V kg 10-4kgm2 Nm
3000 CMP40S 23 11.9 27.5 1.6 0.17 1.9
CMP40M 46 19.9 56.3 1.9 0.22 1.9
CMP50S 71 22.5 86.3 2.7 0.49 2.4
CMP50M 38.5 10.0 90.3 3.7 0.74 2.4
CMP50L 30.5 7.4 98.2 4.6 1.26 3.9
CMP63S 36.5 6.8 90.1 4.6 1.50 3.8
CMP63M 22 3.6 100 6.5 2.41 7.1
CMP63L 14.2 2.1 99.9 8.3 3.15 7.1
4500 CMP40S 23 11.9 27.5 1.6 0.17 1.9
CMP40M 46 19.9 56.3 1.9 0.22 1.9
CMP50S 37 11.6 62.4 2.7 0.49 2.4
CMP50M 20.5 5.3 66.3 3.7 0.74 2.4
CMP50L 14.6 3.6 68 4.6 1.26 3.9
CMP63S 18.3 3.4 63.9 4.6 1.50 3.8
CMP63M 9.8 1.5 67 6.5 2.41 7.1
CMP63L 7.2 1.1 71.1 8.3 3.15 7.1
6000 CMP40S 23 11.9 27.5 1.6 0.17 1.9
CMP40M 34 14.9 48.5 1.9 0.22 1.9
CMP50S 22.5 7.1 48.5 2.7 0.49 2.4
CMP50M 12 3.2 50.5 3.7 0.74 2.4
CMP50L 8.2 1.9 51 4.6 1.26 3.9
CMP63S 11.2 2.1 50 4.6 1.50 3.8
CMP63M 5.9 0.92 52 6.5 2.41 7.1
CMP63L 4 0.62 53 8.3 3.15 7.1

19381212/EN – 03/2015

74 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
CMP71 to CMP100 with BP brake, 400 V system voltage 6
6.4 CMP71 to CMP100 with BP brake, 400 V system voltage
nN Motor L1 R1 Vp0 cold mbmot Jbmot M2, 20 °C
rpm mH Ω V kg 10-4kgm2 Nm
2000 CMP71S 33.5 3.5 128 9 3.5 7 14
CMP71M 21.5 1.9 127 10.4 4.6 14 7
CMP71L 16.2 1.2 142 13.4 6.7 14 7
CMP80S 15.3 1.1 133. 16.8 10.3 16 31
6
CMP80M 10.5 0.69 136 20.5 13.4 31 16
CMP80L 7.6 0.44 149 24.4 19.6 31 16
CMP100S 8.5 0.44 130 22.8 22.0 24 47
CMP100M 6.6 0.30 141 27.8 29.0 47 24
CMP100L 4.15 0.17 145 37.6 42.7 47 24
3000 CMP71S 15.7 1.5 87.5 9 3.5 7 14
CMP71M 9.7 0.81 85.3 10.4 4.6 14 7
CMP71L 7.3 0.56 95.7 13.4 6.7 14 7
CMP80S 7.2 0.54 91.1 16.8 10.3 16 31
CMP80M 5 0.35 94.3 20.5 13.4 31 16
CMP80L 3.35 0.21 99.2 24.4 19.6 31 16
CMP100S 3.9 0.22 88 22.8 22.0 24 47
CMP100M 3.05 0.14 95.5 27.8 29.0 47 24
CMP100L 1.9 0.08 98 37.6 42.7 47 24
4500 CMP71S 7.1 0.72 58.7 9 3.5 7 14
CMP71M 4.55 0.39 58.3 10.4 4.6 14 7
CMP71L 3.25 0.24 63.8 13.4 6.7 14 7
CMP80S 3.05 0.22 59.4 16.8 10.3 16 31
CMP80M 2.25 0.15 62.9 20.5 13.4 31 16
CMP80L 1.54 0.09 67 24.4 19.6 31 16
CMP100S 1.68 0.09 57.7 22.8 22.0 24 47
CMP100M 1.32 0.07 62.9 27.8 29.0 47 24
CMP100L 0.84 0.04 65.3 37.6 42.7 47 24
6000 CMP71S 4.15 0.40 44.9 9 3.5 7 14
CMP71M 2.55 0.21 43.5 10.4 4.6 14 7
CMP71L 1.84 0.15 47.9 13.4 6.7 14 7
CMP80S 1.8 0.14 45.6 – 10.3 – –
CMP80M 1.3 0.09 47.9 – 13.4 – –
CMP80L 0.84 0.05 49.6 – 19.6 – –
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 75


6 Technical data of the motors
CMP112 with BY brake, 400 V system voltage

6.5 CMP112 with BY brake, 400 V system voltage


nN Motor L1 R1 Vp0 cold ΔLB1) mbmot Jbmot M2, 20 °C ΔLBS2)
-4 2
rpm mH Ω V mm kg 10 kgm Nm mm
2000 CMP112S 8.6 0.38 143 – 60.3 102 70 50 –
CMP112M 5.8 0.21 147 – 68.1 132 100 70 –
CMP112L 3.35 0.11 145 – 84.46 192 140 100 –
CMP112H 2.85 0.09 149 – 92.33 221 140 100 –
CMP112E 2.35 0.07 146 – 100.1 251 140 100 –
3000 CMP112S 4.05 1.18 97.5 – 60.3 102 70 50 –
CMP112M 2.5 0.09 96.1 – 68.1 132 100 70 –
CMP112L 1.53 0.05 98 – 84.46 192 140 100 –
CMP112H 1.29 0.04 100 – 92.33 221 140 100 –
CMP112E 1.09 0.03 99.8 – 100.1 251 140 100 –
4500 CMP112S 1.78 0.08 64.7 – 60.3 102 70 50 –
CMP112M 1.14 0.04 65 – 68.1 132 100 70 –
CMP112L 0.68 0.02 65.3 – 84.46 192 140 100 –
CMP112H 0.56 0.02 65.9 – 92.33 221 140 100 –
CMP112E 0.485 0.01 66.5 – 100.1 251 140 100 –
1) Additional length from CMPZ.. motor to the corresponding CMP.. motor
2) Additional length from CMPZ../BY brakemotor to the corresponding CMP../BP brakemotor

19381212/EN – 03/2015

76 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
CMPZ71 to CMPZ100, 400 V system voltage 6
6.6 CMPZ71 to CMPZ100, 400 V system voltage
nN Motor M0 I0 Mpk Imax M0VR I0VR m Jmot
rpm Nm A Nm A Nm A kg 10-4kgm2
2000 CMPZ71S 6.4 3.4 19.2 17 8.7 4.6 8.6 9.4
CMPZ71M 9.4 5 30.8 26 13.7 7.3 10 10.5
CMPZ71L 13.1 6.3 46.9 39 21 10.1 13 12.6
CMPZ80S 13.4 6.9 42.1 33 18.5 9.5 15.8 27.4
6
CMPZ80M 18.7 9.3 62.6 48 27 13.4 19.5 30.5
CMPZ80L 27.5 12.5 107 72 44 20 24.4 36.7
CMPZ100S 25.5 13.3 68.3 49 36 18.8 24.2 80.5
CMPZ100M 31 14.7 108 69 47 22.3 29.2 87.4
CMPZ100L 47 21.8 179 113 70 32.5 39 101
3000 CMPZ71S 6.4 4.9 19.2 25 8.7 6.7 8.6 9.4
CMPZ71M 9.4 7.5 30.8 39 13.7 10.9 10 10.5
CMPZ71L 13.1 9.4 46.9 58 21 15.1 13 12.6
CMPZ80S 13.4 10 42.1 47 18.5 13.8 15.8 27.4
CMPZ80M 18.7 13.4 62.6 69 27 19.3 19.5 30.5
CMPZ80L 27.5 18.7 107 107 44 30 24.4 36.7
CMPZ100S 25.5 19.6 68.3 73 36 27.5 24.2 80.5
CMPZ100M 31 21.8 108 102 47 33 29.2 87.4
CMPZ100L 47 32.3 179 167 70 48 39 101
4500 CMPZ71S 6.4 7.3 19.2 38 8.7 9.9 8.6 9.4
CMPZ71M 9.4 10.9 30.8 57 13.7 15.9 10 10.5
CMPZ71L 13.1 14.1 46.9 87 21 22.5 13 12.6
CMPZ80S 13.4 15.3 42.1 73 18.5 21 15.8 27.4
CMPZ80M 18.7 20.1 62.6 103 27 29 19.5 30.5
CMPZ80L 27.5 27.8 107 159 44 44.5 24.4 36.7
CMPZ100S 25.5 30 68.3 111 36 42.5 24.2 80.5
CMPZ100M 31 33.1 108 154 47 50 29.2 87.4
CMPZ100L 47 48.4 179 251 70 72 39 101
6000 CMPZ71S 6.4 9.6 19.2 50 8.7 13.1 8.6 9.4
CMPZ71M 9.4 14.7 30.8 76 13.7 21.5 10 10.5
CMPZ71L 13.1 18.8 46.9 115 21 30 13 12.6
CMPZ80S 13.4 20 42.1 95 18.5 27.5 15.8 27.4
CMPZ80M 18.7 26.4 62.6 135 27 38 19.5 30.5
CMPZ80L 27.5 37.6 107 215 44 60 24.4 36.7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 77


6 Technical data of the motors
CMPZ71 to CMPZ100 BY brake, 400 V system voltage

6.7 CMPZ71 to CMPZ100 BY brake, 400 V system voltage


nN Motor L1 R1 Vp0 cold ΔLB1) mbmot Jbmot M2, 20 °C ΔLBS2)
-4 2
rpm mH Ω V mm kg 10 kgm Nm mm
2000 CMPZ 71S 33.5 3.5 128 62.6 11.2 11.1 14 10 58.5
CMPZ 71M 21.5 1.9 127 62.6 12.6 12.2 20 14 58.5
CMPZ 71L 16.2 1.2 142 62.6 15.6 14.3 20 14 58.5
CMPZ 80S 15.3 1.1 133 75.3 20.8 31.2 28 20 62.4
CMPZ 80M 10.5 0.69 136 75.3 24.5 34.3 40 28 62.4
CMPZ 80L 7.6 0.44 149 75.3 29.4 40.5 40 28 62.4
CMPZ 100S 8.5 0.44 130 96.2 34.7 84.9 55 40 61.1
CMPZ 100M 6.6 0.30 141 96.2 39.7 91.8 80 55 61.1
CMPZ 100L 4.15 0.17 145 96.2 49.5 105 80 55 61.1
3000 CMPZ 71S 15.7 1.5 87.5 62.6 11.2 11.1 14 10 58.5
CMPZ 71M 9.7 0.81 85.3 62.6 12.6 12.2 20 14 58.5
CMPZ 71L 7.3 0.56 95.7 62.6 15.6 14.3 20 14 58.5
CMPZ 80S 7.2 0.54 91.1 75.3 20.8 31.2 28 20 62.4
CMPZ 80M 5 0.35 94.3 75.3 24.5 34.3 40 28 62.4
CMPZ 80L 3.35 0.21 99.2 75.3 29.4 40.5 40 28 62.4
CMPZ 100S 3.9 0.22 88 96.2 34.7 84.9 55 40 61.1
CMPZ 100M 3.05 0.14 95.5 96.2 39.7 91.8 80 55 61.1
CMPZ 100L 1.9 0.08 98 96.2 49.5 105 80 55 61.1
4500 CMPZ 71S 7.1 0.72 58.7 62.6 11.2 11.1 14 10 58.5
CMPZ 71M 4.55 0.39 58.3 62.6 12.6 12.2 20 14 58.5
CMPZ 71L 3.25 0.24 63.8 62.6 15.6 14.3 20 14 58.5
CMPZ 80S 3.05 0.22 59.4 75.3 20.8 31.2 28 20 62.4
CMPZ 80M 2.25 0.15 62.9 75.3 24.5 34.3 40 28 62.4
CMPZ 80L 1.54 0.09 67 75.3 29.4 40.5 40 28 62.4
CMPZ 100S 1.68 0.09 57.7 96.2 34.7 84.9 55 40 61.1
CMPZ 100M 1.32 0.07 62.9 96.2 39.7 91.8 80 55 61.1
CMPZ 100L 0.84 0.04 65.3 96.2 49.5 105 80 55 61.1
6000 CMPZ 71S 4.15 0.4 44.9 62.6 11.2 11.1 14 10 58.5
CMPZ 71M 2.55 0.21 43.5 62.6 12.6 12.2 20 14 58.5
CMPZ 71L 1.84 0.15 47.9 62.6 15.6 14.3 20 14 58.5
CMPZ 80S 1.8 0.14 45.6 75.3 – 31.2 – – 62.4
CMPZ 80M 1.3 0.09 47.9 75.3 – 34.3 – – 62.4
CMPZ 80L 0.84 0.05 49.6 75.3 – 40.5 – – 62.4
1) Additional length from CMPZ.. motor to the corresponding CMP.. motor
2) Additional length from CMPZ../BY brakemotor to the corresponding CMP../BP brakemotor 19381212/EN – 03/2015

78 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Overview of combinations of CMP. with MOVIAXIS, 400 V system voltage 6
Overview
ofV CMP.of
combinatio
ns
with
MOVIAXIS,
400
system
voltage

6.8 Overview of combinations of CMP. with MOVIAXIS®, 400 V system voltage

INFORMATION
The PWM frequency for MOVIAXIS® can be set to 4 kHz, 8 kHz, and 16 kHz. For
more more project planning information in addition to the overviews of combinations
for 4 kHz shown here, refer to the "MOVIAXIS® Multi-Axis Servo Inverters" system
manual. 6

6.8.1 Rated speed 2000 rpm, PWM 4 kHz


Motor Assignment to MOVIAXIS®
Size 1 2 3 4 5 6
IN A 2 4 8 12 16 24 32 48 64 100
Imax A 5 10 20 30 40 60 80 120 160 250
CMP71S Imax % IN 250
Mpk Nm 15.7
(lb in) (139)
CMP71M Imax % IN 250 250
Mpk Nm 17.6 27.4
(lb in) (156) (243)
CMP71L Imax % IN 250 250
Mpk Nm 36.1 43.9
(lb in) (320) (389)
CMP80S Imax % IN 250 250 206
Mpk Nm 34.0 40.5 42.1
(lb in) (301) (359) (373)
CMP80M Imax % IN 250 250 250
Mpk Nm 38.2 51.1 58.7
(lb in) (338) (453) (520)
CMP80L Imax % IN 250 250 250
Mpk Nm 61.3 77.0 98.7
(lb in) (543) (682) (874)
CMP100S Imax % IN 250 250 204
Mpk Nm 52.2 62.2 68.3
(lb in) (462) (551) (605)
CMP100M Imax % IN 250 250 250 216
Mpk Nm 61.4 78.0 101 108
(lb in) (544) (691) (895) (957)
CMP100L Imax % IN 250 250 235
Mpk Nm 121 148 179
(lb in) (1072) (1311) (1585)
CMP112S Imax % IN 250 250 212
Mpk Nm 60.3 75.5 88.0
(lb in) (534) (669) (779)
CMP112M Imax % IN 250 250 231
Mpk Nm 85.2 118 136
(lb in) (755) (1045) (1205)
CMP112L Imax % IN 250 250 250
Mpk Nm 126 161 219
19381212/EN – 03/2015

(lb in) (1116) (1426) (1940)


CMP112H Imax % IN 250 250 250 231
Mpk Nm 129 168 234 270
(lb in) (1143) (1488) (2072) (2391)
CMP112E Imax % IN 250 250 250 250 175
Mpk Nm 129 170 241 299 320
(lb in) (1143) (1506) (2134) (2648) (2834)

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 79


6 Technical data of the motors
Overview of combinations of CMP. with MOVIAXIS, 400 V system voltage

6.8.2 Rated speed 3000 rpm, PWM 4 kHz


Motor Assignment to MOVIAXIS®
Size 1 2 3 4 5 6
IN A 2 4 8 12 16 24 32 48 64 100
Imax A 5 10 20 30 40 60 80 120 160 250
CMP40S Imax % IN 250
Mpk Nm 1.70
(lb in) (15.1)
CMP40M Imax % IN 250
Mpk Nm 3.44
(lb in) (30.5)
CMP50S Imax % IN 250
Mpk Nm 5.13
(lb in) (45.4)
CMP50M Imax % IN 250 240
Mpk Nm 6.57 10.3
(lb in) (58.2) (91.2)
CMP50L Imax % IN 250 250
Mpk Nm 7.19 12.7
(lb in) (63.7) (112)
CMP63S Imax % IN 250 250
Mpk Nm 6.19 9.86
(lb in) (54.8) (87.3)
CMP63M Imax % IN 250 250
Mpk Nm 13.3 20.7
(lb in) (118) (183)
CMP63L Imax % IN 250 250
Mpk Nm 13.8 23.9
(lb in) (122) (212)
CMP71S Imax % IN 250 250
Mpk Nm 12.2 18.1
(lb in) (108) (160)
CMP71M Imax % IN 250 250 244
Mpk Nm 21.9 27.4 30.8
(lb in) (194) (243) (273)
CMP71L Imax % IN 250 250 250
Mpk Nm 26.4 36.2 42.2
(lb in) (234) (321) (374)
CMP80S Imax % IN 250 250 250
Mpk Nm 25.9 34.7 39.3
(lb in) (229) (307) (348)
CMP80M Imax % IN 250 250 250
Mpk Nm 39.5 48.8 59.6
(lb in) (350) (432) (528)
CMP80L Imax % IN 250 250 250
Mpk Nm 55.5 77.2 92.9
(lb in) (492) (684) (823)
CMP100S Imax % IN 250 250 228
Mpk Nm 48.5 62.7 68.3
(lb in) (430) (555) (605)
CMP100M Imax % IN 250 250 212
19381212/EN – 03/2015

Mpk Nm 78.7 95.4 108


(lb in) (697) (845) (957)
CMP100L Imax % IN 250 250 250 250
Mpk Nm 86.0 111 149 175
(lb in) (762) (983) (1320) (1550)
CMP112S Imax % IN 250 250 231
Mpk Nm 55.5 76.6 88.0
(lb in) (492) (678) (779)

80 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Overview of combinations of CMP. with MOVIAXIS, 400 V system voltage 6
Motor Assignment to MOVIAXIS®
Size 1 2 3 4 5 6
IN A 2 4 8 12 16 24 32 48 64 100
Imax A 5 10 20 30 40 60 80 120 160 250
CMP112M Imax % IN 250 250 235
Mpk Nm 84.1 106 136
(lb in) (745) (939) (1205)
CMP112L Imax % IN 250 250 250 183
Mpk Nm 114 163 203 225
6
(lb in) (1010) (1444) (1798) (1993)
CMP112H Imax % IN 250 250 250 220
Mpk Nm 115 168 214 270
(lb in) (1019) (1488) (1895) (2391)
CMP112E Imax % IN 250 250 250
Mpk Nm 174 224 314
(lb in) (1541) (1984) (2781)
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 81


6 Technical data of the motors
Overview of combinations of CMP. with MOVIAXIS, 400 V system voltage

6.8.3 Rated speed 4500 rpm, PWM 4 kHz


Motor Assignment to MOVIAXIS®
Size 1 2 3 4 5 6
IN A 2 4 8 12 16 24 32 48 64 100
Imax A 5 10 20 30 40 60 80 120 160 250
CMP40S Imax % IN 250
Mpk Nm 1.70
(lb in) (15.1)

CMP40M Imax % IN 250


Mpk Nm 3.44
(lb in) (30.5)

CMP50S Imax % IN 250


Mpk Nm 4.19
(lb in) (37.1)

CMP50M Imax % IN 250 250


Mpk Nm 5.02 8.75
(lb in) (44.5) (77.5)

CMP50L Imax % IN 250


Mpk Nm 9.60
(lb in) (85.0)

CMP63S Imax % IN 250


Mpk Nm 7.96
(lb in) (70.5)

CMP63M Imax % IN 250 250


Mpk Nm 16.4 20.7
(lb in) (145) (183)

CMP63L Imax % IN 250 250 250


Mpk Nm 18.7 25.2 29.8
(lb in) (166) (223) (264)

CMP71S Imax % IN 250 250 238


Mpk Nm 15.0 18.2 19.2
(lb in) (133) (161) (170)

CMP71M Imax % IN 250 250 238


Mpk Nm 22.4 26.4 30.8
(lb in) (198) (234) (273)
CMP71L Imax % IN 250 250 250 250
Mpk Nm 26.4 33.3 42.2 45.8
(lb in) (234) (295) (374) (406)
CMP80S Imax % IN 250 250 250 228
Mpk Nm 25.5 31.8 39.0 42.1
(lb in) (226) (282) (345) (373)
CMP80M Imax % IN 250 250 250
Mpk Nm 35.8 48.8 56.9
(lb in) (317) (432) (504)
19381212/EN – 03/2015

CMP80L Imax % IN 250 250 250 248


Mpk Nm 56.0 71.1 93.4 107
(lb in) (496) (630) (827) (948)

CMP100S Imax % IN 250 250 231


Mpk Nm 47.8 58.2 68.3
(lb in) (423) (515) (605)

82 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Overview of combinations of CMP. with MOVIAXIS, 400 V system voltage 6
Motor Assignment to MOVIAXIS®
Size 1 2 3 4 5 6
IN A 2 4 8 12 16 24 32 48 64 100
Imax A 5 10 20 30 40 60 80 120 160 250
CMP100M Imax % IN 250 250 250 241
Mpk Nm 55.2 71.0 94.7 108
(lb in) (489) (629) (839) (957)
CMP100L Imax % IN 250 250 250 250
Mpk Nm 77.2 111 138 179
6
(lb in) (684) (983) (1222) (1585)
CMP112S Imax % IN 250 250 233
Mpk Nm 55.5 70.3 88.0
(lb in) (492) (623) (779)
CMP112M Imax % IN 250 250 250
Mpk Nm 77.2 108 133
(lb in) (684) (957) (1178)
CMP112L Imax % IN 250 250 250
Mpk Nm 115 148 210
(lb in) (1019) (1311) (1860)
CMP112H Imax % IN 250 250 250
Mpk Nm 114 150 220
(lb in) (1010) (1328) (1948)
CMP112E Imax % IN 250 250
Mpk Nm 155 231
(lb in) (1373) (2046)
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 83


6 Technical data of the motors
Overview of combinations of CMP. with MOVIAXIS, 400 V system voltage

6.8.4 Rated speed 6000 rpm, PWM 4 kHz


Motor Assignment to MOVIAXIS®
Size 1 2 3 4 5 6
IN A 2 4 8 12 16 24 32 48 64 100
Imax A 5 10 20 30 40 60 80 120 160 250
CMP40S Imax % IN 250
Mpk Nm 1.70
(lb in) (15.1)
CMP40M Imax % IN 250
Mpk Nm 3.12
(lb in) (27.6)
CMP50S Imax % IN 250 225
Mpk Nm 3.46 5.20
(lb in) (30.6) (46.1)
CMP50M Imax % IN 250
Mpk Nm 7.19
(lb in) (63.7)
CMP50L Imax % IN 250 250
Mpk Nm 7.49 13.1
(lb in) (66.3) (116)
CMP63S Imax % IN 250 250
Mpk Nm 6.67 10.4
(lb in) (59.1) (92.1)
CMP63M Imax % IN 250 250 250
Mpk Nm 13.7 18.1 21.1
(lb in) (121) (160) (187)
CMP63L Imax % IN 250 250 250
Mpk Nm 14.5 20.3 25.0
(lb in) (128) (180) (221)
CMP71S Imax % IN 250 250 250
Mpk Nm 12.4 16.2 18.3
(lb in) (110) (143) (162)
CMP71M Imax % IN 250 250 250 238
Mpk Nm 17.9 22.2 27.7 30.8
(lb in) (159) (197) (245) (273)
CMP71L Imax % IN 250 250 250
Mpk Nm 26.4 36.2 42.2
(lb in) (234) (321) (374)
CMP80S Imax % IN 250 250 250
Mpk Nm 25.9 34.7 39.3
(lb in) (229) (307) (348)
CMP80M Imax % IN 250 250 250
Mpk Nm 40.0 49.2 59.9
(lb in) (354) (436) (531)
CMP80L Imax % IN 250 250 250 250
Mpk Nm 42.5 55.3 76.9 92.7
(lb in) (376) (490) (681) (821)
19381212/EN – 03/2015

84 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Overview of combinations of CMP. with MOVIDRIVE, 400 V system voltage 6
Overview
with CMP.of
combinatio
,ns of V
MOVIDRIVE
400
system
voltage

6.9 Overview of combinations of CMP. with MOVIDRIVE®, 400 V system


voltage

INFORMATION
Due to the higher output frequency, the following motors must be operated with a
PWM frequency of at least 8 kHz:
• CMP40 to 63 for speed class 6000 rpm 6
• CMP71 to 112 for speed classes 4500 rpm and 6000 rpm

INFORMATION
The following project planning guidelines apply to the operation of CMP71 to 112 mo-
tors:
• The motor load must not exceed a maximum of four times the rated motor current
I0.
• The current of MOVIDRIVE® B must be limited to the following values:
– For size 0 to 166% IN
– For sizes 1 to 6 to 125% IN
• The following combination overviews take account of these project planning
guidelines.

6.9.1 Rated speed 2000 rpm, PWM 4 kHz, sizes 0 to 2


Motor Assignment to MOVIDRIVE®
0005 00008 0011 0014 0015 0022 0030 0040 0055 0075 0110
IN A 2 2.4 3.1 4 4 5.5 7 9.5 12.5 16 24
Imax A 4 4.5 6.2 8 6 8.25 10.5 14.3 18.8 24 36
CMP.71S Imax % IN 166 166 166 166 125 125 125 125 109
Mpk Nm 6.47 7.64 9.58 11.8 9.34 12.1 14.4 17.1 18.0
(lb in) (57.3) (67.7) (84.8) (105) (82.7) (107) (128) (151) (159)
CMP.71M Imax % IN 166 166 125 125 125 125 125 125
Mpk Nm 9.63 12.3 9.37 12.7 15.7 20.1 24.2 27.4
(lb in) (85.3) (109) (83.0) (112) (139) (178) (214) (243)
CMP.71L Imax % IN 166 125 125 125 125 125 125 105
Mpk Nm 13.6 10.2 14.1 17.8 23.7 30.0 36.1 41.1
(lb in) (120) (90.3) (125) (158) (210) (266) (320) (364)
CMP.80S Imax % IN 166 125 125 125 125 125 125 115
Mpk Nm 12.7 9.48 13.2 16.9 22.7 28.7 34.0 39.3
(lb in) (112) (84.0) (117) (150) (201) (254) (301) (348)
CMP.80M Imax % IN 125 125 125 125 125 125
Mpk Nm 13.9 17.7 23.8 30.8 38.2 51.1
(lb in) (123) (157) (211) (273) (338) (453)
CMP.80L Imax % IN 125 125 125 125 125
Mpk Nm 19.1 25.9 33.7 42.6 61.3
(lb in) (169) (229) (298) (377) (543)
19381212/EN – 03/2015

CMP.100S Imax % IN 125 125 125 125 125


Mpk Nm 17.0 23.0 30.0 37.6 52.2
(lb in) (151) (204) (266) (333) (462)
CMP.100M Imax % IN 125 125 125 125
Mpk Nm 25.0 32.9 42.0 61.4
(lb in) (221) (291) (372) (544)
CMP.100L Imax % IN 125 125 125
Mpk Nm 34.0 43.5 64.8
(lb in) (301) (385) (574)

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 85


6 Technical data of the motors
Overview of combinations of CMP. with MOVIDRIVE, 400 V system voltage

Motor Assignment to MOVIDRIVE®


0005 00008 0011 0014 0015 0022 0030 0040 0055 0075 0110
IN A 2 2.4 3.1 4 4 5.5 7 9.5 12.5 16 24
Imax A 4 4.5 6.2 8 6 8.25 10.5 14.3 18.8 24 36
CMP112S Imax % IN 150 150 150 150 150
Mpk Nm 21.9 29.9 39.2 49.5 69.8
(lb in) (194) (265) (347) (438) (618)
CMP112M Imax % IN 150 150 150
Mpk Nm 42.0 53.4 77.7
(lb in) (372) (473) (688)
CMP112L Imax % IN 150 150
Mpk Nm 52.9 78.3
(lb in) (469) (693)
CMP112H Imax % IN 150
Mpk Nm 78.3
(lb in) (693)
CMP112E Imax % IN 150
Mpk Nm 77.2
(lb in) (684)

19381212/EN – 03/2015

86 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Overview of combinations of CMP. with MOVIDRIVE, 400 V system voltage 6
6.9.2 Rated speed 2000 rpm, PWM 4 kHz, sizes 3 to 6
Motor Assignment to MOVIDRIVE®
0150 0220 0300 0370 0450 0550 0750
IN A 32 46 60 73 89 105 130
Imax A 48 69 90 109.5 133.5 157.5 195
CMP.80M Imax % IN 116
Mpk Nm 57.0
(lb in) (505)
6
CMP.80L Imax % IN 125 109
Mpk Nm 77.0 89.4
(lb in) (682) (792)
CMP.100S Imax % IN 125 107
Mpk Nm 62.2 68.3
(lb in) (551) (605)
CMP.100M Imax % IN 125 125 98.0
Mpk Nm 78.0 98.8 100.0
(lb in) (691) (875) (886)
CMP.100L Imax % IN 125 125 125 119
Mpk Nm 85.1 117 142 156
(lb in) (754) (1036) (1258) (1382)
CMP112S Imax % IN 150 111
Mpk Nm 85.1 88.0
(lb in) (754) (779)
CMP112M Imax % IN 150 150 123
Mpk Nm 99.2 130 136
(lb in) (879) (1151) (1205)
CMP112L Imax % IN 150 150 150 150 139
Mpk Nm 103 142 177 206 225
(lb in) (912) (1258) (1568) (1824) (1993)
CMP112H Imax % IN 150 150 150 150 150 141
Mpk Nm 104 147 186 219 253 270
(lb in) (921) (1302) (1647) (1940) (2241) (2391)
CMP112E Imax % IN 150 150 150 150 150 150 135
Mpk Nm 103 148 189 224 262 296 320
(lb in) (912) (1311) (1674) (1984) (2320) (2622) (2834)
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 87


6 Technical data of the motors
Overview of combinations of CMP. with MOVIDRIVE, 400 V system voltage

6.9.3 Rated speed 3000 rpm, PWM 4 kHz, sizes 0 to 2


Motor Assignment to MOVIDRIVE®
0005 00008 0011 0014 0015 0022 0030 0040 0055 0075 0110
IN A 2 2.4 3.1 4 4 5.5 7 9.5 12.5 16 24
Imax A 4 4.5 6.2 8 6 8.25 10.5 14.3 18.8 24 36
CMP40S Imax % IN 200 200 197 150
Mpk Nm 1.46 1.65 1.90 1.89
(lb in) (12.9) (14.6) (16.8) (16.7)
CMP40M Imax % IN 200 200 194 150
Mpk Nm 2.96 3.35 3.80 3.80
(lb in) (26.2) (29.7) (33.7) (33.7)
CMP50S Imax % IN 200 200 165 127 92.7
Mpk Nm 4.47 5.01 5.20 5.20 5.20
(lb in) (39.6) (44.4) (46.1) (46.1) (46.1)
CMP50M Imax % IN 200 200 200 200 150 150 137
Mpk Nm 5.44 6.35 7.78 9.29 7.58 9.47 10.3
(lb in) (48.2) (56.2) (68.9) (82.3) (67.1) (83.9) (91.2)
CMP50L Imax % IN 200 200 200 200 150 150 150 143
Mpk Nm 5.86 6.93 8.68 10.7 8.44 11.0 13.1 15.4
(lb in) (51.9) (61.4) (76.9) (94.8) (74.8) (97.4) (116) (136)
CMP63S Imax % IN 200 200 200 200 150 150 150 136
Mpk Nm 5.18 6.00 7.28 8.65 7.11 8.82 10.1 11.1
(lb in) (45.9) (53.1) (64.5) (76.6) (63.0) (78.1) (89.5) (98.3)
CMP63M Imax % IN 200 200 200 200 150 150 150 150 150 135
Mpk Nm 6.08 7.18 8.99 11.1 8.74 11.4 13.8 17.1 20.1 21.4
(lb in) (53.8) (63.6) (79.6) (98.3) (77.4) (101) (122) (151) (178) (190)
CMP63L Imax % IN 200 200 150 150 150 150 150 150 124
Mpk Nm 8.93 11.3 8.66 11.6 14.4 18.5 22.9 27.0 30.4
(lb in) (79.1) (100) (76.7) (103) (128) (164) (203) (239) (269)
CMP.71S Imax % IN 166 166 125 125 125 125 125 123
Mpk Nm 6.92 8.70 6.74 8.97 11.0 13.9 16.4 18.0
(lb in) (61.3) (77.1) (59.7) (79.4) (97.4) (123) (145) (159)
CMP.71M Imax % IN 166 125 125 125 125 125 125 125
Mpk Nm 8.33 6.32 8.62 10.9 14.4 18.2 21.9 27.4
(lb in) (73.8) (56.0) (76.3) (96.5) (128) (161) (194) (243)
CMP.71L Imax % IN 125 125 125 125 125 125
Mpk Nm 9.44 12.0 16.2 21.1 26.4 36.2
(lb in) (83.6) (106) (143) (187) (234) (321)
CMP.80S Imax % IN 125 125 125 125 125 125
Mpk Nm 8.98 11.5 15.8 20.7 25.9 34.7
(lb in) (79.5) (102) (140) (183) (229) (307)
CMP.80M Imax % IN 125 125 125 125 125
Mpk Nm 12.3 16.7 21.8 27.6 39.5
(lb in) (109) (148) (193) (244) (350)
CMP.80L Imax % IN 125 125 125 125
Mpk Nm 17.4 22.8 29.0 42.8
(lb in) (154) (202) (257) (379)
CMP100S Imax % IN 125 125 125
Mpk Nm 20.5 26.2 38.2
(lb in) (182) (232) (338)
CMP.100M Imax % IN 125 125 125
19381212/EN – 03/2015

Mpk Nm 22.2 28.4 42.5


(lb in) (197) (252) (376)
CMP.100L Imax % IN 125
Mpk Nm 44.0
(lb in) (390)
CMP112S Imax % IN 150 150 150
Mpk Nm 26.7 34.2 50.4
(lb in) (236) (303) (446)

88 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Overview of combinations of CMP. with MOVIDRIVE, 400 V system voltage 6
Motor Assignment to MOVIDRIVE®
0005 00008 0011 0014 0015 0022 0030 0040 0055 0075 0110
IN A 2 2.4 3.1 4 4 5.5 7 9.5 12.5 16 24
Imax A 4 4.5 6.2 8 6 8.25 10.5 14.3 18.8 24 36
CMP112M Imax % IN 150 150
Mpk Nm 35.4 52.6
(lb in) (314) (466)
CMP112L Imax % IN 150
Mpk Nm 53.4
6
(lb in) (473)
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 89


6 Technical data of the motors
Overview of combinations of CMP. with MOVIDRIVE, 400 V system voltage

6.9.4 Rated speed 3000 rpm, PWM 4 kHz, sizes 3 to 6


Motor Assignment to MOVIDRIVE®
0150 0220 0300 0370 0450 0550 0750 0900 1100
IN A 32 46 60 73 89 105 130 170 200
Imax A 48 69 90 109.5 133.5 157.5 195 255 300
CMP.71L Imax % IN 118
Mpk Nm 41.1
(lb in) (364)
CMP.80S Imax % IN 125
Mpk Nm 39.3
(lb in) (348)
CMP.80M Imax % IN 125 117
Mpk Nm 48.8 57.0
(lb in) (432) (505)
CMP.80L Imax % IN 125 125 125
Mpk Nm 55.5 74.8 89.4
(lb in) (492) (662) (792)
CMP.100S Imax % IN 125 125 122
Mpk Nm 48.5 61.4 68.3
(lb in) (430) (544) (605)
CMP.100M Imax % IN 125 125 125 119
Mpk Nm 55.8 76.1 91.8 100.0
(lb in) (494) (674) (813) (886)
CMP.100L Imax % IN 125 125 125 125 125 123
Mpk Nm 58.5 82.7 105 123 142 156
(lb in) (518) (732) (930) (1089) (1258) (1382)
CMP112S Imax % IN 150 150 123
Mpk Nm 64.7 84.0 88.0
(lb in) (573) (744) (779)
CMP112M Imax % IN 150 150 150 150 127
Mpk Nm 68.9 94.6 116 133 136
(lb in) (610) (838) (1027) (1178) (1205)
CMP112L Imax % IN 150 150 150 150 150 150 141
Mpk Nm 70.6 99.6 127 151 177 201 225
(lb in) (625) (882) (1125) (1337) (1568) (1780) (1993)
CMP112H Imax % IN 150 150 150 150 150 150 150 129
Mpk Nm 69.6 99.6 129 155 184 211 248 270
(lb in) (616) (882) (1143) (1373) (1630) (1869) (2196) (2391)
CMP112E Imax % IN 150 150 150 150 150 150 150 150 128
Mpk Nm 70.4 102 132 160 192 221 262 320 320
(lb in) (624) (903) (1169) (1417) (1700) (1957) (2320) (2834) (2834)
19381212/EN – 03/2015

90 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Overview of combinations of CMP. with MOVIDRIVE, 400 V system voltage 6
6.9.5 Rated speed 4500 rpm, PWM 4 kHz, sizes 0 to 2
Motor Assignment to MOVIDRIVE®
0005 0008 0011 0014 0015 0022 0030 0040 0055 0075 0110
IN A 2 2.4 3.1 4 4 5.5 7 9.5 12.5 16 24
Imax A 4 4.5 6.2 8 6 8.25 10.5 14.3 18.8 24 36
CMP40S Imax % IN 200 200 197 150
Mpk Nm 1.46 1.65 1.90 1.89
(lb in) (12.9) (14.6) (16.8) (16.7)
6
CMP40M Imax % IN 200 200 194 150
Mpk Nm 2.96 3.35 3.80 3.80
(lb in) (26.2) (29.7) (33.7) (33.7)
CMP50S Imax % IN 200 200 200 175 150 127
Mpk Nm 3.54 4.07 4.83 5.20 4.73 5.20
(lb in) (31.4) (36.0) (42.8) (46.1) (41.9) (46.1)
CMP50M Imax % IN 200 200 200 200 150 150 150 138
Mpk Nm 4.11 4.85 6.05 7.43 5.88 7.61 9.04 10.3
(lb in) (36.4) (43.0) (53.6) (65.8) (52.1) (67.4) (80.1) (91.2)
CMP50L Imax % IN 200 200 197 150 150 150 150 150
Mpk Nm 1.46 1.65 1.90 6.12 8.15 10.00 12.6 15.1
(lb in) (12.9) (14.6) (16.8) (54.2) (72.2) (88.6) (112) (134)
CMP63S Imax % IN 200 200 200 200 150 150 150 150 146
Mpk Nm 3.84 4.50 5.57 6.79 5.42 6.95 8.23 9.88 11.1
(lb in) (34.0) (39.9) (49.3) (60.1) (48.0) (61.6) (72.9) (87.5) (98.3)
CMP63M Imax % IN 200 200 194 150 150 150 150 150 150 135
Mpk Nm 2.96 3.35 3.80 6.08 8.10 9.97 12.8 15.7 18.4 21.4
(lb in) (26.2) (29.7) (33.7) (53.8) (71.7) (88.3) (113) (139) (163) (190)
CMP63L Imax % IN 200 150 150 150 150 150 150 150
Mpk Nm 8.31 6.33 8.55 10.7 14.0 17.7 21.5 28.2
(lb in) (73.6) (56.1) (75.7) (94.8) (124) (157) (190) (250)
CMP71S Imax % IN 166 125 125 125 125 125 125 122
Mpk Nm 6.06 4.63 6.26 7.80 10.2 12.7 15.0 18.0
(lb in) (53.7) (41.0) (55.4) (69.1) (90.3) (112) (133) (159)
CMP71M Imax % IN 125 125 125 125 125 125
Mpk Nm 5.98 7.58 10.2 13.1 16.3 22.4
(lb in) (53.0) (67.1) (90.3) (116) (144) (198)
CMP71L Imax % IN 125 125 125 125
Mpk Nm 10.9 14.3 18.2 26.4
(lb in) (96.5) (127) (161) (234)
CMP80S Imax % IN 125 125 125 125
Mpk Nm 10.2 13.5 17.4 25.5
(lb in) (90.3) (120) (154) (226)
CMP80M Imax % IN 125 125 125
Mpk Nm 14.6 18.7 27.6
(lb in) (129) (166) (244)
CMP80L Imax % IN 125 125
Mpk Nm 19.7 29.3
(lb in) (174) (260)
CMP100S Imax % IN 125 125
Mpk Nm 17.2 25.7
(lb in) (152) (228)
CMP100M Imax % IN 125
19381212/EN – 03/2015

Mpk Nm 28.1
(lb in) (249)
CMP112S Imax % IN 150 150
Mpk Nm 22.8 34.2
(lb in) (202) (303)
CMP112M Imax % IN 150
Mpk Nm 36.2
(lb in) (321)

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 91


6 Technical data of the motors
Overview of combinations of CMP. with MOVIDRIVE, 400 V system voltage

6.9.6 Rated speed 4500 rpm, PWM 4 kHz, sizes 3 to 6


Motor Assignment to MOVIDRIVE®
0150 0220 0300 0370 0450 0550 0750 0900 1100 1320 1600
IN A 32 46 60 73 89 105 130 170 200 250 300
Imax A 48 69 90 109.5 133.5 157.5 195 255 300 375 450
CMP63L Imax % IN 129
Mpk Nm 30.4
(lb in) (269)
CMP71S Imax % IN
Mpk Nm
(lb in)
CMP71M Imax % IN 125 94.8
Mpk Nm 26.4 27.4
(lb in) (234) (243)
CMP71L Imax % IN 125 123
Mpk Nm 33.3 41.1
(lb in) (295) (364)
CMP80S Imax % IN 125 125 102
Mpk Nm 31.8 38.4 39.3
(lb in) (282) (340) (348)
CMP80M Imax % IN 125 125 125 110
Mpk Nm 35.8 47.4 55.3 57.0
(lb in) (317) (420) (490) (505)
CMP80L Imax % IN 125 125 125 125 125
Mpk Nm 38.6 53.9 67.5 78.5 89.4
(lb in) (342) (477) (598) (695) (792)
CMP100S Imax % IN 125 125 125 125 125
Mpk Nm 33.7 46.2 56.0 62.5 68.3
(lb in) (298) (409) (496) (554) (605)
CMP100M Imax % IN 125 125 125 125 125 125 102
Mpk Nm 37.4 53.0 67.2 78.8 90.4 99.5 100.0
(lb in) (331) (469) (595) (698) (801) (881) (886)
CMP100L Imax % IN 125 125 125 125 125 125 125 114
Mpk Nm 39.2 56.2 72.6 87.2 104 119 140 156
(lb in) (347) (498) (643) (772) (921) (1054) (1240) (1382)
CMP112S Imax % IN 150 150 150 150 126
Mpk Nm 45.2 62.5 76.6 87.0 88.0
(lb in) (400) (554) (678) (771) (779)
CMP112M Imax % IN 150 150 150 150 150 150 129
Mpk Nm 47.9 67.5 85.6 101 117 131 136
(lb in) (424) (598) (758) (895) (1036) (1160) (1205)
CMP112L Imax % IN 150 150 150 150 150 150 150 138
Mpk Nm 68.2 87.9 106 126 146 174 213 225
(lb in) (604) (779) (939) (1116) (1293) (1541) (1886) (1993)
CMP112H Imax % IN 150 150 150 150 150 150 150 150 134
Mpk Nm 66.3 86.4 105 127 148 179 223 251 270
(lb in) (587) (765) (930) (1125) (1311) (1585) (1975) (2223) (2391)
CMP112E Imax % IN 150 150 150 150 150 150 150 150 128
Mpk Nm 87.8 107 130 153 186 235 266 313 320
(lb in) (778) (948) (1151) (1355) (1647) (2081) (2356) (2772) (2834)
19381212/EN – 03/2015

92 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Overview of combinations of CMP. with MOVIDRIVE, 400 V system voltage 6
6.9.7 Rated speed 4500 rpm, PWM 8 kHz, sizes 0 to 2
Motor Assignment to MOVIDRIVE®
0005 0008 0011 0014 0015 0022 0030 0040 0055 0075 0110
IN A 2 2.4 3.1 4 4 5.5 7 9.5 12.5 16 24
Imax A 4 4.5 6.2 8 6 8.25 10.5 14.3 18.8 24 36
CMP40S Imax % IN 200 200 197 129 111
Mpk Nm 1.46 1.65 1.90 1.73 1.90
(lb in) (12.9) (14.6) (16.8) (15.3) (16.8)
6
CMP40M Imax % IN 200 200 194 129 109
Mpk Nm 2.96 3.35 3.80 3.51 3.80
(lb in) (26.2) (29.7) (33.7) (31.1) (33.7)
CMP50S Imax % IN 200 200 200 175 129 127
Mpk Nm 3.54 4.07 4.83 5.20 4.28 5.20
(lb in) (31.4) (36.0) (42.8) (46.1) (37.9) (46.1)
CMP50M Imax % IN 200 200 200 200 129 129 129 129 105
Mpk Nm 4.11 4.85 6.05 7.43 5.17 6.76 8.14 9.95 10.3
(lb in) (36.4) (43.0) (53.6) (65.8) (45.8) (59.9) (72.1) (88.1) (91.2)
CMP50L Imax % IN 200 200 200 200 129 129 129 129 129 122
Mpk Nm 4.18 4.97 6.31 7.93 5.32 7.13 8.81 11.3 13.7 15.4
(lb in) (37.0) (44.0) (55.9) (70.2) (47.1) (63.1) (78.0) (100) (121) (136)
CMP63S Imax % IN 200 200 200 200 129 129 129 129 129 114
Mpk Nm 3.84 4.50 5.57 6.79 4.78 6.20 7.42 9.07 10.5 11.1
(lb in) (34.0) (39.9) (49.3) (60.1) (42.3) (54.9) (65.7) (80.3) (93.0) (98.3)
CMP63M Imax % IN 200 200 129 129 129 129 129 129 129
Mpk Nm 6.27 7.88 5.29 7.08 8.77 11.3 14.1 16.7 21.0
(lb in) (55.5) (69.8) (46.9) (62.7) (77.7) (100) (125) (148) (186)
CMP63L Imax % IN 200 129 129 129 129 129 129 129
Mpk Nm 8.31 5.48 7.42 9.30 12.3 15.6 19.1 25.7
(lb in) (73.6) (48.5) (65.7) (82.4) (109) (138) (169) (228)
CMP.71S Imax % IN 166 125 125 125 125 125 125 122
Mpk Nm 6.06 4.63 6.26 7.80 10.2 12.7 15.0 18.0
(lb in) (53.7) (41.0) (55.4) (69.1) (90.3) (112) (133) (159)
CMP.71M Imax % IN 125 125 125 125 125 125
Mpk Nm 5.98 7.58 10.2 13.1 16.3 22.4
(lb in) (53.0) (67.1) (90.3) (116) (144) (198)
CMP.71L Imax % IN 125 125 125 125
Mpk Nm 10.9 14.3 18.2 26.4
(lb in) (96.5) (127) (161) (234)
CMP.80S Imax % IN 125 125 125 125
Mpk Nm 10.2 13.5 17.4 25.5
(lb in) (90.3) (120) (154) (226)
CMP.80M Imax % IN 125 125 125
Mpk Nm 14.6 18.7 27.6
(lb in) (129) (166) (244)
CMP.80L Imax % IN 125 125
Mpk Nm 19.7 29.3
(lb in) (174) (260)
CMP.100S Imax % IN 125 125
Mpk Nm 17.2 25.7
(lb in) (152) (228)
CMP.100M Imax % IN 125
19381212/EN – 03/2015

Mpk Nm 28.1
(lb in) (249)
CMP112S Imax % IN 129 129
Mpk Nm 19.5 29.5
(lb in) (173) (261)
CMP112M Imax % IN 129
Mpk Nm 31.1
(lb in) (275)

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 93


6 Technical data of the motors
Overview of combinations of CMP. with MOVIDRIVE, 400 V system voltage

6.9.8 Rated speed 4500 rpm, PWM 8 kHz, sizes 3 to 6


Motor Assignment to MOVIDRIVE®
0150 0220 0300 0370 0450 0550 0750 0900 1100 1320 1600
IN A 32 46 60 73 89 105 130 170 200 250 300
Imax A 48 69 90 109.5 133.5 157.5 195 255 300 375 450
CMP63M Imax % IN 101
Mpk Nm 21.4
(lb in) (190)
CMP63L Imax % IN 129 90.0
Mpk Nm 30.3 30.4
(lb in) (268) (269)
CMP.71M Imax % IN 125 94.8
Mpk Nm 26.4 27.4
(lb in) (234) (243)
CMP.71L Imax % IN 125 123
Mpk Nm 33.3 41.1
(lb in) (295) (364)
CMP.80S Imax % IN 125 125 102
Mpk Nm 31.8 38.4 39.3
(lb in) (282) (340) (348)
CMP.80M Imax % IN 125 125 125 110
Mpk Nm 35.8 47.4 55.3 57.0
(lb in) (317) (420) (490) (505)
CMP.80L Imax % IN 125 125 125 125 125
Mpk Nm 38.6 53.9 67.5 78.5 89.4
(lb in) (342) (477) (598) (695) (792)
CMP.100S Imax % IN 125 125 125 125 125
Mpk Nm 33.7 46.2 56.0 62.5 68.3
(lb in) (298) (409) (496) (554) (605)
CMP.100M Imax % IN 125 125 125 125 125 125 102
Mpk Nm 37.4 53.0 67.2 78.8 90.4 99.5 100.0
(lb in) (331) (469) (595) (698) (801) (881) (886)
CMP.100L Imax % IN 125 125 125 125 125 125 125 114
Mpk Nm 39.2 56.2 72.6 87.2 104 119 140 156
(lb in) (347) (498) (643) (772) (921) (1054) (1240) (1382)
CMP112S Imax % IN 129 129 129 129 126
Mpk Nm 39.1 54.9 68.5 79.0 88.0
(lb in) (346) (486) (607) (700) (779)
CMP112M Imax % IN 129 129 129 129 129 129 129 98.8
Mpk Nm 41.4 58.7 75.0 89.0 105 118 136 136
(lb in) (367) (520) (664) (788) (930) (1045) (1205) (1205)
CMP112L Imax % IN 129 129 129 129 129 129 129 129 110
Mpk Nm 58.9 76.2 91.7 110 128 154 191 215 225
(lb in) (522) (675) (812) (974) (1134) (1364) (1692) (1904) (1993)
CMP112H Imax % IN 129 129 129 129 129 129 129 129 129 112
Mpk Nm 57.1 74.4 90.3 110 128 157 198 225 264 270
(lb in) (506) (659) (800) (974) (1134) (1390) (1754) (1993) (2338) (2391)
CMP112E Imax % IN 129 129 129 129 129 129 129 129 128
Mpk Nm 75.4 91.9 112 132 162 207 237 281 320
(lb in) (668) (814) (992) (1169) (1435) (1833) (2099) (2489) (2834)
19381212/EN – 03/2015

94 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Overview of combinations of CMP. with MOVIDRIVE, 400 V system voltage 6
6.9.9 Rated speed 6000 rpm, 8 kHz, sizes 0 to 2
Motor Assignment to MOVIDRIVE®
0005 0008 0011 0014 0015 0022 0030 0040 0055 0075 0110
IN A 2 2.4 3.1 4 4 5.5 7 9.5 12.5 16 24
Imax A 4 4.5 6.2 8 6 8.25 10.5 14.3 18.8 24 36
CMP40S Imax % IN 200 200 197 129 111
Mpk Nm 1.46 1.65 1.90 1.73 1.90
(lb in) (12.9) (14.6) (16.8) (15.3) (16.8)
6
CMP40M Imax % IN 200 200 200 172 129 125
Mpk Nm 2.64 3.04 3.58 3.80 3.19 3.80
(lb in) (23.4) (26.9) (31.7) (33.7) (28.3) (33.7)
CMP50S Imax % IN 200 200 200 200 129 129 129 94.7
Mpk Nm 2.88 3.35 4.08 4.83 3.55 4.48 5.20 5.20
(lb in) (25.5) (29.7) (36.1) (42.8) (31.4) (39.7) (46.1) (46.1)
CMP50M Imax % IN 200 200 200 200 129 129 129 129 129 107
Mpk Nm 3.22 3.81 4.80 5.99 4.07 5.41 6.63 8.37 10.00 10.3
(lb in) (28.5) (33.7) (42.5) (53.1) (36.0) (47.9) (58.7) (74.1) (88.6) (91.2)
CMP50L Imax % IN 200 200 200 129 129 129 129 129 129 108
Mpk Nm 3.78 4.82 6.12 4.05 5.47 6.84 8.95 11.2 13.4 15.4
(lb in) (33.5) (42.7) (54.2) (35.9) (48.4) (60.6) (79.3) (99.2) (119) (136)
CMP63S Imax % IN 200 200 200 200 129 129 129 129 129 129 97.5
Mpk Nm 3.09 3.63 4.54 5.61 3.87 5.08 6.17 7.73 9.23 10.5 11.1
(lb in) (27.4) (32.1) (40.2) (49.7) (34.3) (45.0) (54.6) (68.5) (81.7) (93.0) (98.3)
CMP63M Imax % IN 200 129 129 129 129 129 129 129
Mpk Nm 6.32 4.21 5.66 7.06 9.23 11.6 14.1 18.5
(lb in) (56.0) (37.3) (50.1) (62.5) (81.7) (103) (125) (164)
CMP63L Imax % IN 129 129 129 129 129 129
Mpk Nm 5.58 7.03 9.36 12.0 14.9 20.8
(lb in) (49.4) (62.3) (82.9) (106) (132) (184)
CMP71S 125 125 125 125 125 125
4.83 6.07 8.03 10.2 12.4 16.2
(42.8) (53.8) (71.1) (90.3) (110) (143)
CMP71M 125 125 125 125
7.62 9.94 12.5 17.9
(67.5) (88.0) (111) (159)
CMP71L 125 125 125 125
8.14 10.7 13.7 20.3
(72.1) (94.8) (121) (180)
CMP80S 125 125 125
10.3 13.3 19.9
(91.2) (118) (176)
CMP80M 125 125
14.3 21.3
(127) (189)
CMP80L 125
21.8
(193)
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 95


6 Technical data of the motors
Overview of combinations of CMP. with MOVIDRIVE, 400 V system voltage

6.9.10 Rated speed 6000 rpm, 8 kHz, sizes 3 to 6


Motor Assignment to MOVIDRIVE®
0150 0220 0300 0370 0450 0550 0750
IN A 32 46 60 73 89 105 130
Imax A 48 69 90 109.5 133.5 157.5 195
CMP63M Imax % IN 129 90.0
Mpk Nm 21.4 21.4
(lb in) (190) (190)
CMP63L Imax % IN 129 121 93.0
Mpk Nm 25.5 30.4 30.4
(lb in) (226) (269) (269)
CMP71S Imax % IN 120
Mpk Nm 18.0
(lb in) (159)
CMP71M Imax % IN 125 125 98.0
Mpk Nm 22.2 27.2 27.4
(lb in) (197) (241) (243)
CMP71L Imax % IN 125 125 125 103
Mpk Nm 26.4 35.2 41.1 41.1
(lb in) (234) (312) (364) (364)
CMP80S Imax % IN 125 125 125 110
Mpk Nm 25.9 33.8 38.4 39.3
(lb in) (229) (299) (340) (348)
CMP80M Imax % IN 125 125 125 125 119
Mpk Nm 28.0 38.6 47.2 53.2 57.0
(lb in) (248) (342) (418) (471) (505)
CMP80L Imax % IN 125 125 125 125 125 125 116
Mpk Nm 28.9 40.9 52.2 61.9 72.6 81.9 89.4
(lb in) (256) (362) (462) (548) (643) (725) (792)

19381212/EN – 03/2015

96 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage 6
6.10 Dynamic and thermal characteristic curves, 400 V system voltage
For the maximum available torque, refer to the "Overview of combinations of CMP.
with MOVIDRIVE, 400 V system voltage (→ 2 85) and "Overview of combinations of
CMP. with MOVIAXIS®, 400 V system voltage".
Definition:
• M = Maximum dynamic torque for a maximum line voltage on the inverter of 360 V,
400 V, 460 V or 500 V 6
• M S1 (derating) = thermal limit characteristic curve in S1 – 100% operation

Key:
M S1 M S1 thermal (derating)
DC 750 V controlled on DC 750 V constant
500 V 500 V line voltage, non-controlled
460 V 460 V line voltage, non-controlled
400 V 400 V line voltage, non-controlled
360 V 360 V line voltage, non-controlled

6.10.1 CMP40S 3000 rpm

2
360V

400V

1.5 460V

500V

DC 750V
M [Nm]

1
M S1

0.5

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13817257483
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 97


6 Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage

6.10.2 CMP40S 4500 rpm

2
360V

400V

1.5 460V

500V

DC 750V
M [Nm]

1
M S1

0.5

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13818245003

6.10.3 CMP40S 6000 rpm

2
360V

400V

1.5 460V

500V

DC 750V
M [Nm]

1
M S1

0.5

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13818246923
19381212/EN – 03/2015

98 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage 6
6.10.4 CMP40M 3000 rpm

4
360V
3.5
400V

3 460V

500V
2.5
DC 750V
6
M [Nm]

2
M S1

1.5

0.5

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13817250955

6.10.5 CMP40M 4500 rpm

4
360V
3.5
400V

3 460V

500V
2.5
DC 750V
M [Nm]

2
M S1

1.5

0.5

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13817252875
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 99


6 Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage

6.10.6 CMP40M 6000 rpm

360V
3.5
400V

3 460V

500V
2.5
DC 750V
M [Nm]

2
M S1

1.5

0.5

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13817254795

6.10.7 CMP50S 3000 rpm

360V
5
400V

460V
4
500V

3 DC 750V
M [Nm]

M S1

2 M S1 /VR

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818275467
19381212/EN – 03/2015

100 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage 6
6.10.8 CMP50S 4500 rpm

360V
5
400V

4 460V

500V

DC 750V
6
3
M [Nm]

M S1

2 M S1 /VR

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13818277387

6.10.9 CMP50S 6000 rpm

360V
5
400V

4 460V

500V

3 DC 750V
M [Nm]

M S1

2 M S1 /VR

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13818279307
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 101


6 Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage

6.10.10 CMP50M 3000 rpm

360V
10
400V

8 460V

500V

6 DC 750V
M [Nm]

M S1

4 M S1 /VR

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818256139

6.10.11 CMP50M 4500 rpm

360V
10
400V

8 460V

500V

6 DC 750V
M [Nm]

M S1

4 M S1 /VR

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13818270859
19381212/EN – 03/2015

102 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage 6
6.10.12 CMP50M 6000 rpm

360V
10
400V

8 460V

500V

DC 750V
6
6
M [Nm]

M S1

4 M S1 /VR

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13818272779

6.10.13 CMP50L 3000 rpm

16
360V

14 400V

12 460V

500V
10
DC 750V
M [Nm]

8
M S1

6 M S1 /VR

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818249611
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 103


6 Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage

6.10.14 CMP50L 4500 rpm

16
360V

14 400V

12 460V

500V
10
DC 750V
M [Nm]

8
M S1

6 M S1 /VR

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13818251531

6.10.15 CMP50L 6000 rpm

16
360V

14 400V

12 460V

500V
10
DC 750V
M [Nm]

8
M S1

6 M S1 /VR

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13818253451
19381212/EN – 03/2015

104 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage 6
6.10.16 CMP63S 3000 rpm

360V

10 400V

460V
8
500V

DC 750V
6
M [Nm]

6
M S1

M S1 /VR
4

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818295051

6.10.17 CMP63S 4500 rpm

360V

10 400V

460V
8
500V

DC 750V
M [Nm]

6
M S1

M S1 /VR
4

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13818360971
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 105


6 Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage

6.10.18 CMP63S 6000 rpm

360V

10 400V

460V
8
500V

DC 750V
M [Nm]

6
M S1

M S1 /VR
4

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13818362891

6.10.19 CMP63M 3000 rpm

360V M S1
20
400V M S1 /VR

460V M S1, BK

15 500V

DC 750V
M [Nm]

10

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818288523
19381212/EN – 03/2015

106 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage 6
6.10.20 CMP63M 4500 rpm

360V M S1
20
400V M S1 /VR

460V M S1, BK

15 500V

DC 750V
6
M [Nm]

10

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13818290443

6.10.21 CMP63M 6000 rpm

360V M S1
20
400V M S1 /VR

460V M S1, BK

15 500V

DC 750V
M [Nm]

10

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13818292363
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 107


6 Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage

6.10.22 CMP63L 3000 rpm

30 360V M S1

400V M S1 /VR
25
460V M S1, BK

500V
20
DC 750V
M [Nm]

15

10

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818281995

6.10.23 CMP63L 4500 rpm

30 360V M S1

400V M S1 /VR
25
460V M S1, BK

500V
20
DC 750V
M [Nm]

15

10

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13818283915
19381212/EN – 03/2015

108 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage 6
6.10.24 CMP63L 6000 rpm

30 360V M S1

400V M S1 /VR
25
460V M S1, BK

500V
20
DC 750V
6
M [Nm]

15

10

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13818285835

6.10.25 CMP71S 2000 rpm

20
360V

400V

15 460V

500V

DC 750V
M [Nm]

10
M S1

M S1 /VR

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818395787
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 109


6 Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage

6.10.26 CMP71S 3000 rpm

20
360V

400V

15 460V

500V

DC 750V
M [Nm]

10
M S1

M S1 /VR

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818397707

6.10.27 CMP71S 4500 rpm

20
360V

400V

15 460V

500V

DC 750V
M [Nm]

10
M S1

M S1 /VR

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13818412427
19381212/EN – 03/2015

110 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage 6
6.10.28 CMP71S 6000 rpm

20
360V

400V

15 460V

500V

DC 750V
6
M [Nm]

10
M S1

M S1 /VR

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13818414347

6.10.29 CMP71M 2000 rpm

30 360V

400V
25
460V

500V
20
DC 750V
M [Nm]

15 M S1

M S1 /VR
10

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818387083
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 111


6 Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage

6.10.30 CMP71M 3000 rpm

360V
30
400V

25 460V

500V
20
DC 750V
M [Nm]

15 M S1

M S1 /VR
10

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13818389003

6.10.31 CMP71M 4500 rpm

360V
30
400V
25 460V

500V
20
DC 750V
M [Nm]

15 M S1

M S1 /VR
10

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13818390923
19381212/EN – 03/2015

112 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage 6
6.10.32 CMP71M 6000 rpm

30 360V

400V
25
460V

500V
20
DC 750V
6
M [Nm]

15 M S1

M S1 /VR
10

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13818392843

6.10.33 CMP71L 2000 rpm

360V
45
400V
40
460V
35
500V
30
DC 750V
M [Nm]

25
M S1
20
M S1 /VR
15

10

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818365579
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 113


6 Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage

6.10.34 CMP71L 3000 rpm

360V
45
400V
40
460V
35
500V
30
DC 750V
M [Nm]

25
M S1
20
M S1 /VR
15

10

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818367499

6.10.35 CMP71L 4500 rpm

360V
45
400V
40
460V
35
500V
30
DC 750V
M [Nm]

25
M S1
20
M S1 /VR
15

10

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13818369419
19381212/EN – 03/2015

114 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage 6
6.10.36 CMP71L 6000 rpm

360V
45
400V
40
460V
35
500V
30
DC 750V
6
M [Nm]

25
M S1
20
M S1 /VR
15

10

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13818371339

6.10.37 CMP80S 2000 rpm

360V
40
400V
35
460V

30 500V

25 DC 750V
M [Nm]

20 M S1

M S1 /VR
15

10

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818434699
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 115


6 Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage

6.10.38 CMP80S 3000 rpm

360V
40
400V
35
460V
30
500V

25 DC 750V
M [Nm]

20 M S1

M S1 /VR
15

10

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818449419

6.10.39 CMP80S 4500 rpm

360V
40
400V
35
460V
30 500V

25 DC 750V
M [Nm]

20 M S1

M S1 /VR
15

10

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13818451339
19381212/EN – 03/2015

116 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage 6
6.10.40 CMP80S 6000 rpm

360V
40
400V
35
460V
30 500V

25 DC 750V
6
M [Nm]

20 M S1

M S1 /VR
15

10

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13818453259

6.10.41 CMP80M 2000 rpm

360V
60
400V

50 460V

500V
40
DC 750V
M [Nm]

30 M S1

M S1 /VR
20

10

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818425995
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 117


6 Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage

6.10.42 CMP80M 3000 rpm

360V
60
400V

50 460V

500V
40
DC 750V
M [Nm]

30 M S1

M S1 /VR
20

10

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818427915

6.10.43 CMP80M 4500 rpm

360V
60
400V

50 460V

500V
40
DC 750V
M [Nm]

30 M S1

M S1 /VR
20

10

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13818429835
19381212/EN – 03/2015

118 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage 6
6.10.44 CMP80M 6000 rpm

360V
60
400V

50 460V

500V
40
DC 750V
6
M [Nm]

30 M S1

M S1 /VR
20

10

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13818431755

6.10.45 CMP80L 2000 rpm

360V
100
400V

460V
80
500V

DC 750V
M [Nm]

60
M S1

40 M S1 /VR

20

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818417291
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 119


6 Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage

6.10.46 CMP80L 3000 rpm

360V
100
400V

460V
80
500V

DC 750V
M [Nm]

60
M S1

40 M S1 /VR

20

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818419211

6.10.47 CMP80L 4500 rpm

360V
100
400V

460V
80
500V

DC 750V
M [Nm]

60
M S1

40 M S1 /VR

20

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13818421131
19381212/EN – 03/2015

120 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage 6
6.10.48 CMP80L 6000 rpm

360V
100
400V

460V
80
500V

DC 750V
6
M [Nm]

60
M S1

40 M S1 /VR

20

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13818423051

6.10.49 CMP100S 2000 rpm

70
360V

60 400V

460V
50
500V

40 DC 750V
M [Nm]

M S1
30
M S1 /VR

20

10

0
0 500 1000 1500 2000 2500 3000 3500 4000 4500
n [1/min]

13818482059
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 121


6 Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage

6.10.50 CMP100S 3000 rpm

70
360V

60 400V

460V
50
500V

40 DC 750V
M [Nm]

M S1
30
M S1 /VR

20

10

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818483979

6.10.51 CMP100S 4500 rpm

70
360V

60 400V

460V
50
500V

40 DC 750V
M [Nm]

M S1
30
M S1 /VR

20

10

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818485899
19381212/EN – 03/2015

122 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage 6
6.10.52 CMP100M 2000 rpm

360V
100
400V

460V
80
500V

DC 750V
6
M [Nm]

60
M S1

40 M S1 /VR

20

0
0 500 1000 1500 2000 2500 3000 3500 4000 4500
n [1/min]

13818475531

6.10.53 CMP100M 3000 rpm

360V
100
400V

460V
80
500V

DC 750V
M [Nm]

60
M S1

40 M S1 /VR

20

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818477451
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 123


6 Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage

6.10.54 CMP100M 4500 rpm

360V
100
400V

460V
80
500V

DC 750V
M [Nm]

60
M S1

40 M S1 /VR

20

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818479371

6.10.55 CMP100L 2000 rpm

180 360V

160 400V

140 460V

120 500V

DC 750V
M [Nm]

100
M S1
80
M S1 /VR
60

40

20

0
0 500 1000 1500 2000 2500 3000 3500 4000
n [1/min]

13818456203
19381212/EN – 03/2015

124 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage 6
6.10.56 CMP100L 3000 rpm

180 360V

160 400V

140 460V

120 500V

DC 750V
6
M [Nm]

100
M S1
80
M S1 /VR
60

40

20

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818458123

6.10.57 CMP100L 4500 rpm

180 360V

160 400V

140 460V

120 500V

DC 750V
M [Nm]

100
M S1
80
M S1 /VR
60

40

20

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818460043
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 125


6 Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage

6.10.58 CMP112S 2000 rpm

90 360V

80 400V

70 460V

60 500V

DC 750V
M [Nm]

50
M S1
40
M S1 /VR
30

20

10

0
0 500 1000 1500 2000 2500 3000 3500 4000 4500
n [1/min]

13818540299

6.10.59 CMP112S 3000 rpm

90
360V

80 400V

70 460V

60 500V

DC 750V
M [Nm]

50
M S1
40
M S1 /VR
30

20

10

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818542219
19381212/EN – 03/2015

126 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage 6
6.10.60 CMP112S 4500 rpm

90
360V

80 400V

70 460V

60 500V

DC 750V
6
M [Nm]

50
M S1
40
M S1 /VR
30

20

10

0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000
n [1/min]

13818544139

6.10.61 CMP112M 2000 rpm

140
360V

120 400V

460V
100
500V

80 DC 750V
M [Nm]

M S1
60
M S1 /VR

40

20

0
0 500 1000 1500 2000 2500 3000 3500 4000 4500
n [1/min]

13818520971
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 127


6 Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage

6.10.62 CMP112M 3000 rpm

140
360V

120 400V

460V
100
500V

80 DC 750V
M [Nm]

M S1
60
M S1 /VR

40

20

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818522891

6.10.63 CMP112M 4500 rpm

140
360V

120 400V

460V
100
500V

80 DC 750V
M [Nm]

M S1
60
M S1 /VR

40

20

0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000
n [1/min]

13818524811
19381212/EN – 03/2015

128 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage 6
6.10.64 CMP112L 2000 rpm

360V

200 400V

460V

500V
150
DC 750V
6
M [Nm]

M S1
100
M S1 /VR

50

0
0 500 1000 1500 2000 2500 3000 3500 4000 4500
n [1/min]

13818514443

6.10.65 CMP112L 3000 rpm

360V

200 400V

460V

500V
150
DC 750V
M [Nm]

M S1
100
M S1 /VR

50

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818516363
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 129


6 Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage

6.10.66 CMP112L 4500 rpm

360V

200 400V

460V

500V
150
DC 750V
M [Nm]

M S1
100
M S1 /VR

50

0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000
n [1/min]

13818518283

6.10.67 CMP112H 2000 rpm

360V
250
400V

460V
200
500V

DC 750V
M [Nm]

150
M S1

100 M S1 /VR

50

0
0 500 1000 1500 2000 2500 3000 3500 4000 4500
n [1/min]

13818507915
19381212/EN – 03/2015

130 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage 6
6.10.68 CMP112H 3000 rpm

360V
250
400V

460V
200
500V

DC 750V
6
M [Nm]

150
M S1

100 M S1 /VR

50

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818509835

6.10.69 CMP112H 4500 rpm

360V
250
400V

460V
200
500V

DC 750V
M [Nm]

150
M S1

100 M S1 /VR

50

0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000
n [1/min]

13818511755
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 131


6 Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage

6.10.70 CMP112E 2000 rpm

360V
300
400V

250 460V

500V
200
DC 750V
M [Nm]

150 M S1

M S1 /VR
100

50

0
0 500 1000 1500 2000 2500 3000 3500 4000 4500
n [1/min]

13818501387

6.10.71 CMP112E 3000 rpm

360V
300
400V

250 460V

500V
200
DC 750V
M [Nm]

150 M S1

M S1 /VR
100

50

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13818503307
19381212/EN – 03/2015

132 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 400 V system voltage 6
6.10.72 CMP112E 4500 rpm

360V
300
400V

250 460V

500V
200
DC 750V
6
M [Nm]

150 M S1

M S1 /VR
100

50

0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000
n [1/min]

13818505227
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 133


6 Technical data of the motors
CMP40 to 100, 230 V system voltage

6.11 CMP40 to 100, 230 V system voltage


nN Motor M0 I0 Mpk Imax M0VR I0VR m Jmot
rpm Nm A Nm A Nm A kg 10-4kgm2
3000 CMP40S 0.5 1.2 1.9 6.1 – – 1.3 0.10
CMP40M 0.8 1.5 3.8 9 – – 1.6 0.15
CMP50S 1.3 1.64 5.2 9.8 – – 2.3 0.42
CMP50M 2.4 2.84 10.3 17.1 – – 3.3 0.67
CMP50L 3.3 3.84 15.4 23.1 – – 4.1 0.92
CMP63S 2.9 3.61 11.1 21.7 – – 4.0 1.2
CMP63M 5.3 6.35 21.4 38.1 – – 5.7 1.9
CMP63L 7.1 8.76 30.4 52.6 – – 7.5 2.7
CMP71S 6.4 8.7 19.2 44 8.7 11.8 7 3.1
CMP71M 9.4 13.1 30.8 68 13.7 19.1 8.4 4.2
CMP71L 13.1 16.8 46.9 103 21 27 11.4 6.3
CMP80S 13.4 17.7 42.1 83 18.5 24.5 12.8 9.0
CMP80M 18.7 23.5 62.6 121 27 34 16.5 12.1
CMP80L 27.5 32.5 107 186 44 52 21.4 18.3
CMP100S 25.5 34.2 68.3 127 – – 19.8 20.3
CMP100M 31 40 108 187 – – 24.8 27.2
CMP100L 47 58.1 179 300 – – 34.6 40.9
4500 CMP40S 0.5 1.2 1.9 6.1 – – 1.3 0.10
CMP40M 0.8 1.5 3.8 9 – – 1.6 0.15
CMP50S 1.3 2.29 5.2 13.8 – – 2.3 0.42
CMP50M 2.4 4.03 10.3 24.2 – – 3.3 0.67
CMP50L 3.3 5.53 15.4 33.2 – – 4.1 0.92
CMP63S 2.9 5.25 11.1 31.5 – – 4.0 1.2
CMP63M 5.3 9.78 21.4 58.7 – – 5.7 1.9
CMP63L 7.1 12 30.4 72.1 – – 7.5 2.7
CMP71S 6.4 12.8 19.2 67 8.7 17.4 7 3.1
CMP71M 9.4 19.2 30.8 101 13.7 28 8.4 4.2
CMP71L 13.1 25.6 46.9 158 – – 11.4 6.3
CMP80S 13.4 27 42.1 129 18.5 37 12.8 9.0
CMP80M 18.7 35 62.6 180 27 51 16.5 12.1
CMP80L 27.5 49.9 107 285 – – 21.4 18.3
CMP100S 25.5 54.5 68.3 200 – – 21.4 20.3
CMP100M 31 60 108 279 – – 19.8 27.2
6000 CMP40S 0.5 1.36 1.9 6.8 – – 1.3 0.10
CMP40M 0.8 1.91 3.8 11.5 – – 1.6 0.15
CMP50S 1.3 3.07 5.2 18.5 – – 2.3 0.42
CMP50M 2.4 5.25 10.3 31.5 – – 3.3 0.67
CMP50L 3.3 7.6 15.4 45.4 – – 4.1 0.92
CMP63S 2.9 6.78 11.1 40.7 – – 4.0 1.2
CMP63M 5.3 12.1 21.4 72.4 – – 5.7 1.9
CMP71S 6.4 17 19.2 89 8.7 23 7 3.1
CMP71M 9.4 26.3 30.8 136 – – 8.4 4.2
CMP80S 13.4 35.5 42.1 168 18.5 48.5 12.8 9.0
CMP80M 18.7 46.9 62.6 240 – – 16.5 12.1
19381212/EN – 03/2015

CMP80L 27.5 68 107 389 – – 21.4 18.3

134 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
CMP40 to 63 with BK brake, 230 V system voltage 6
6.12 CMP40 to 63 with BK brake, 230 V system voltage
nN Motor L1 R1 Vp0 cold mbmot Jbmot M4,120°C
rpm mH Ω V kg 10-4kgm2 Nm
3000 CMP40S 23 11.9 27.5 1.6 0.17 1.9
CMP40M 18.4 7.9 35.7 1.9 0.22 1.9
CMP50S 24.5 7.4 50.4 2.7 0.49 2.4
CMP50M 13.5 3.4 53.7 3.7 0.74 2.4
6
CMP50L 9.8 2.4 55.7 4.6 1.26 3.9
CMP63S 13 2.6 54 4.6 1.5 3.8
CMP63M 7.1 1.1 57 6.5 2.41 7.1
CMP63L 4.45 0.66 56 8.3 3.15 7.1
4500 CMP40S 23 11.9 27.5 1.6 0.17 1.9
CMP40M 18.4 7.9 35.7 1.9 0.22 1.9
CMP50S 12.3 3.8 35.9 2.7 0.49 2.4
CMP50M 6.8 1.7 37.9 3.7 0.74 2.4
CMP50L 4.75 1.1 38.7 4.6 1.26 3.9
CMP63S 6.2 1.1 37.1 4.6 1.5 3.8
CMP63M 3 0.46 37 6.5 2.41 7.1
CMP63L 2.4 0.34 40.9 8.3 3.15 7.1
6000 CMP40S 17.9 9.2 24.3 1.6 0.17 1.9
CMP40M 11.2 4.9 27.8 1.9 0.22 1.9
CMP50S 6.9 2.0 26.8 2.7 0.49 2.4
CMP50M 3.95 1.0 29 3.7 0.74 2.4
CMP50L 2.55 0.60 28.3 4.6 1.26 3.9
CMP63S 3.7 0.67 28.7 4.6 1.5 3.8
CMP63M 1.96 0.30 30 6.5 2.41 7.1
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 135


6 Technical data of the motors
CMP71 to 100 with BP brake, 230 V system voltage

6.13 CMP71 to 100 with BP brake, 230 V system voltage


nN Motor L1 R1 Vp0 cold mbmot Jbmot M2, 20 °C
rpm mH Ω V kg 10-4kgm2 Nm
3000 CMP71S 5 0.49 49.5 9.0 3.5 7.0 14
CMP71M 3.15 0.26 48.7 10.4 4.6 14 7.0
CMP71L 2.3 0.16 53.7 13.4 6.7 14 7.0
CMP80S 2.3 0.17 51.5 16.8 10.3 16 31
CMP80M 1.64 0.11 53.9 20.5 13.4 31 16
CMP80L 1.11 0.07 57 24.4 19.6 31 16
CMP100S 1.29 0.07 50.5 22.8 22.0 24 47
CMP100M 0.9 0.04 52.1 27.8 29.0 47 24
4500 CMP71S 2.3 0.23 33.4 9.0 3.5 7 14
CMP71M 1.46 0.13 33.1 10.4 4.6 14 7
CMP80S 0.98 0.07 33.7 16.8 10.3 16 31
CMP80M 0.73 0.05 35.9 20.5 13.4 31 16
CMP100S 0.51 0.03 31.7 22.8 22.0 24 47
6000 CMP71S 1.32 0.12 25.3 9.0 3.5 7 14
CMP80S 0.58 0.04 25.7 16.8 10.3 – –

6.14 CMPZ71 to CMPZ100, 230 V system voltage


nN Motor M0 I0 Mpk Imax M0VR I0VR m Jmot
rpm Nm A Nm A Nm A kg 10 kgm2
-4

3000 CMPZ71S 6.4 8.7 19.2 44 8.7 11.8 8.6 9.4


CMPZ71M 9.4 13.1 30.8 68 13.7 19.1 10 10.5
CMPZ71L 13.1 16.8 46.9 103 21 27 13 12.6
CMPZ80S 13.4 17.7 42.1 83 18.5 24.5 15.8 27.4
CMPZ80M 18.7 23.5 62.6 121 27 34 19.5 30.5
CMPZ80L 27.5 32.5 107 186 44 52 24.4 36.7
CMPZ100S 25.5 34.2 68.3 127 – – 24.2 80.5
CMPZ100M 31 40 108 187 – – 29.2 87.4
CMPZ100L 47 58.1 179 300 – – 39 101
4500 CMPZ71S 6.4 12.8 19.2 67 8.7 17.4 8.6 9.4
CMPZ71M 9.4 19.2 30.8 101 13.7 28 10 10.5
CMPZ71L 13.1 25.6 46.9 158 – – 13 12.6
CMPZ80S 13.4 27 42.1 129 18.5 37 15.8 27.4
CMPZ80M 18.7 35 62.6 180 27 51 19.5 30.5
CMPZ80L 27.5 49.9 107 285 – – 24.4 36.7
CMPZ100S 25.5 54.5 68.3 200 – – 24.2 80.5
CMPZ100M 31 60 108 279 – – 29.2 87.4
6000 CMPZ71S 6.4 17 19.2 89 8.7 23 8.6 9.4
CMPZ71M 9.4 26.3 30.8 136 – – 10 10.5
CMPZ80S 13.4 35.5 42.1 168 18.5 48.5 15.8 27.4
CMPZ80M 18.7 46.9 62.6 240 – – 19.5 30.5
CMPZ80L 27.5 68 107 389 – – 24.4 36.7
19381212/EN – 03/2015

136 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
CMPZ71 to CMPZ100 with BY brake, 230 V system voltage 6
6.15 CMPZ71 to CMPZ100 with BY brake, 230 V system voltage
nN Motor L1 R1 Vp0 cold ΔLB1) mbmot Jbmot M2, 20 °C ΔLBS2)
-4 2
rpm mH Ω V mm kg 10 kgm Nm mm
3000 CMPZ 71S 5 485 49.5 62.6 11.2 11.1 14 10 58.5
CMPZ 71M 3.15 260 48.7 62.6 12.6 12.2 20 14 58.5
CMPZ 71L 2.3 162 53.7 62.6 15.6 14.3 20 14 58.5
CMPZ 80S 2.3 166 51.5 75.3 20.8 31.2 28 20 62.4
6
CMPZ 80M 1.64 113 53.9 75.3 24.5 34.3 40 28 62.4
CMPZ 80L 1.11 73 57 75.3 29.4 40.5 40 28 62.4
CMPZ 100S 1.29 66 50.5 96.2 34.7 84.9 55 40 61.1
CMPZ 100M 0.9 44.50 52.1 96.2 39.7 91.8 80 55 61.1
CMPZ 100L 0.59 25 54.4 96.2 49.5 105 80 55 61.1
4500 CMPZ 71S 2.3 225 33.4 62.6 11.2 11.1 14 10 58.5
CMPZ 71M 1.46 127 33.1 62.6 12.6 12.2 20 14 58.5
CMPZ 71L 1.05 76 36.3 62.6 15.6 14.3 20 14 58.5
CMPZ 80S 0.98 70 33.7 75.3 20.8 31.2 28 20 62.4
CMPZ 80M 0.73 51 35.9 75.3 24.5 34.3 40 28 62.4
CMPZ 80L 0,475 30.50 37.2 75.3 29.4 40.5 40 28 62.4
CMPZ 100S 0.51 27 31.7 96.2 34.7 84.9 55 40 61.1
CMPZ 100M 0.4 17.90 34.7 96.2 39.7 91.8 80 55 61.1
6000 CMPZ 71S 1.32 124 25.3 62.6 11.2 11.1 14 10 58.5
CMPZ 71M 0.79 66 24.4 62.6 12.6 12.2 20 14 58.5
CMPZ 80S 0.58 41.50 25.7 62.6 20.8 31.2 28 20 62.4
CMPZ 80M 0.41 28 26.9 75.3 24.5 34.3 40 28 62.4
CMPZ 80L 0,255 15.50 27.3 75.3 29.4 40.5 40 28 62.4
1) Additional length from CMPZ.. motor to the corresponding CMP.. motor
2) Additional length from CMPZ../BY brakemotor to the corresponding CMP../BP brakemotor
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 137


6 Technical data of the motors
Overview of combinations of CMP. with MOVIDRIVE, 230 V system voltage

Overview
with CMP.of
combinatio
,ns of V
MOVIDRIVE
230
system
voltage

6.16 Overview of combinations of CMP. with MOVIDRIVE®, 230 V system


voltage

INFORMATION
Due to the higher output frequency, the following motors must be operated with a
PWM frequency of at least 8 kHz:
• CMP40 to 63 for speed class 6000 rpm
• CMP71 to 112 for speed classes 4500 rpm and 6000 rpm

INFORMATION
The following project planning guidelines apply to the operation of CMP71 to 112 mo-
tors:
• The motor load must not exceed a maximum of four times the rated motor current
I0.
• The current of MOVIDRIVE® B must be limited to the following values:
– For size 0 to 166% IN
– For sizes 1 to 6 to 125% IN
• The following combination overviews take account of these project planning
guidelines.

6.16.1 Rated speed 3000 rpm, PWM 4 kHz, sizes 1 to 4


Motor Assignment to MOVIDRIVE®
0015 0022 0037 0055 0075 0110 0150 0220 0300
IN A 7.3 8.6 14.5 22 29 42 54 80 95
Imax A 11 12.9 21.8 33 43.5 63 81 120 143
Imax_CMP71-100 A 9.13 10.8 18.1 27.5 36.3 52.5 67.5 100 119
CMP40S Imax % IN 83.6
Mpk Nm 1.90
(lb in) (16.8)
CMP40M Imax % IN 123
Mpk Nm 3.80
(lb in) (33.7)
CMP50S Imax % IN 134
Mpk Nm 5.20
(lb in) (46.1)
CMP50M Imax % IN 150 150 118
Mpk Nm 8.03 9.01 10.3
(lb in) (71.1) (79.8) (91.2)
CMP50L Imax % IN 150 150 150 105
Mpk Nm 8.77 10.1 14.6 15.4
(lb in) (77.7) (89.5) (129) (136)
CMP63S Imax % IN 150 150 149
Mpk Nm 7.54 8.43 11.1
19381212/EN – 03/2015

(lb in) (66.8) (74.7) (98.3)


CMP63M Imax % IN 150 150 150 150 131
Mpk Nm 9.00 10.3 15.5 20.0 21.4
(lb in) (79.7) (91.2) (137) (177) (190)
CMP63L Imax % IN 150 150 150 150 150 125
Mpk Nm 8.91 10.4 16.4 22.8 27.4 30.4
(lb in) (78.9) (92.1) (145) (202) (243) (269)

138 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Overview of combinations of CMP. with MOVIDRIVE, 230 V system voltage 6
Motor Assignment to MOVIDRIVE®
0015 0022 0037 0055 0075 0110 0150 0220 0300
IN A 7.3 8.6 14.5 22 29 42 54 80 95
Imax A 11 12.9 21.8 33 43.5 63 81 120 143
Imax_CMP71-100 A 9.13 10.8 18.1 27.5 36.3 52.5 67.5 100 119
CMP.71S Imax % IN 125 125 125 125 120
Mpk Nm 6.91 8.02 12.4 16.3 18.0
(lb in) (61.2) (71.0) (110) (144) (159)
CMP.71M Imax % IN 125 125 125 125 125 125
6
Mpk Nm 6.59 7.74 12.7 18.3 22.4 27.4
(lb in) (58.4) (68.6) (112) (162) (198) (243)
CMP.71L Imax % IN 125 125 125 125 125 124
Mpk Nm 8.25 13.9 20.8 26.7 35.7 41.1
(lb in) (73.1) (123) (184) (236) (316) (364)
CMP.80S Imax % IN 125 125 125 125 125 88.5
Mpk Nm 13.6 20.6 26.4 34.4 38.6 39.3
(lb in) (120) (182) (234) (305) (342) (348)
CMP.80M Imax % IN 125 125 125 125 125 118
Mpk Nm 14.5 21.9 28.5 39.4 47.5 57.0
(lb in) (128) (194) (252) (349) (421) (505)
CMP.80L Imax % IN 125 125 125 125 125 125
Mpk Nm 23.1 30.2 43.0 54.1 74.8 84.5
(lb in) (205) (267) (381) (479) (662) (748)
CMP.100S Imax % IN 125 125 125 125 125 125
Mpk Nm 20.7 27.2 38.3 47.3 61.3 66.4
(lb in) (183) (241) (339) (419) (543) (588)
CMP.100M Imax % IN 125 125 125 125 125 125
Mpk Nm 21.2 28.1 40.6 51.6 72.9 83.2
(lb in) (188) (249) (360) (457) (646) (737)
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 139


6 Technical data of the motors
Overview of combinations of CMP. with MOVIDRIVE, 230 V system voltage

6.16.2 Rated speed 4500 rpm, PWM 4 kHz, sizes 1 to 4


Motor Assignment to MOVIDRIVE®
0015 0022 0037 0055 0075 0110 0150 0220 0300
IN A 7.3 8.6 14.5 22 29 42 54 80 95
Imax A 11 12.9 21.8 33 43.5 63 81 120 143
Imax_CMP71-100 A 9.13 10.8 18.1 27.5 36.3 52.5 67.5 100 119
CMP40S Imax % IN 83.6
Mpk Nm 1.90
(lb in) (16.8)
CMP40M Imax % IN 123
Mpk Nm 3.80
(lb in) (33.7)
CMP50S Imax % IN 150 150
Mpk Nm 4.88 5.20
(lb in) (43.2) (46.1)
CMP50M Imax % IN 150 150 150 110
Mpk Nm 6.10 6.97 10.0 10.3
(lb in) (54.0) (61.7) (88.6) (91.2)
CMP50L Imax % IN 150 150 150 150 114
Mpk Nm 6.34 7.36 11.4 15.1 15.4
(lb in) (56.2) (65.2) (101) (134) (136)
CMP63S Imax % IN 150 150 150 143
Mpk Nm 5.68 6.46 9.24 11.1
(lb in) (50.3) (57.2) (81.8) (98.3)
CMP63M Imax % IN 150 150 150 150 150 140
Mpk Nm 6.13 7.11 11.2 15.4 18.4 21.4
(lb in) (54.3) (63.0) (99.2) (136) (163) (190)
CMP63L Imax % IN 150 150 150 150 150 150 133
Mpk Nm 6.62 7.73 12.5 17.9 22.1 28.2 30.4
(lb in) (58.6) (68.5) (111) (159) (196) (250) (269)
CMP71S Imax % IN 125 125 125 125 125 122
Mpk Nm 4.81 5.62 9.04 12.7 15.3 18.0
(lb in) (42.6) (49.8) (80.1) (112) (136) (159)
CMP71M Imax % IN 125 125 125 125 125 96.0
Mpk Nm 8.87 13.1 16.7 22.3 25.8 27.4
(lb in) (78.6) (116) (148) (198) (229) (243)
CMP80S Imax % IN 125 125 125 125 125 125
Mpk Nm 8.75 13.5 17.9 25.3 30.9 38.2
(lb in) (77.5) (120) (159) (224) (274) (338)
CMP80M Imax % IN 125 125 125 125 125 125
Mpk Nm 14.8 19.4 27.8 34.8 47.4 52.6
(lb in) (131) (172) (246) (308) (420) (466)
CMP100S Imax % IN 125 125 125 125 125
Mpk Nm 17.1 24.8 31.5 44.6 51.0
(lb in) (151) (220) (279) (395) (452)
19381212/EN – 03/2015

140 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Overview of combinations of CMP. with MOVIDRIVE, 230 V system voltage 6
6.16.3 Rated speed 4500 rpm, PWM 8 kHz, sizes 1 to 4
Motor Assignment to MOVIDRIVE®
0015 0022 0037 0055 0075 0110 0150 0220 0300
IN A 7.3 8.6 14.5 22 29 42 54 80 95
Imax A 11 12.9 21.8 33 43.5 63 81 120 143
Imax_CMP71-100 A 9.13 10.8 18.1 27.5 36.3 52.5 67.5 100 119
CMP40S Imax % IN 83.6
Mpk Nm 1.90 6
(lb in) (16.8)
CMP40M Imax % IN 123
Mpk Nm 3.80
(lb in) (33.7)
CMP50S Imax % IN 129 129 94.8
Mpk Nm 4.43 4.92 5.20
(lb in) (39.2) (43.6) (46.1)
CMP50M Imax % IN 129 129 129 110
Mpk Nm 5.36 6.16 9.14 10.3
(lb in) (47.5) (54.6) (80.9) (91.2)
CMP50L Imax % IN 129 129 129 129 114
Mpk Nm 5.52 6.42 10.1 13.8 15.4
(lb in) (48.9) (56.9) (89.5) (122) (136)
CMP63S Imax % IN 129 129 129 129 109
Mpk Nm 5.02 5.74 8.41 10.6 11.1
(lb in) (44.5) (50.8) (74.5) (93.9) (98.3)
CMP63M Imax % IN 129 129 129 129 129 129 109
Mpk Nm 5.33 6.20 9.84 13.8 16.7 20.7 21.4
(lb in) (47.2) (54.9) (87.1) (122) (148) (183) (190)
CMP63L Imax % IN 129 129 129 129 129 129 129 90.1
Mpk Nm 5.73 6.70 10.9 15.8 19.7 25.8 29.8 30.4
(lb in) (50.7) (59.3) (96.5) (140) (174) (229) (264) (269)
CMP.71S Imax % IN 125 125 125 125 125 122
Mpk Nm 4.81 5.62 9.04 12.7 15.3 18.0
(lb in) (42.6) (49.8) (80.1) (112) (136) (159)
CMP.71M Imax % IN 125 125 125 125 125 96.0
Mpk Nm 8.87 13.1 16.7 22.3 25.8 27.4
(lb in) (78.6) (116) (148) (198) (229) (243)
CMP.80S Imax % IN 125 125 125 125 125 125
Mpk Nm 8.75 13.5 17.9 25.3 30.9 38.2
(lb in) (77.5) (120) (159) (224) (274) (338)
CMP.80M Imax % IN 125 125 125 125 125 125
Mpk Nm 14.8 19.4 27.8 34.8 47.4 52.6
(lb in) (131) (172) (246) (308) (420) (466)
CMP.100S Imax % IN 125 125 125 125 125
Mpk Nm 17.1 24.8 31.5 44.6 51.0
(lb in) (151) (220) (279) (395) (452)
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 141


6 Technical data of the motors
Overview of combinations of CMP. with MOVIDRIVE, 230 V system voltage

6.16.4 Rated speed 6000 rpm, PWM 8 kHz, sizes 1 to 4


Motor Assignment to MOVIDRIVE®
0015 0022 0037 0055 0075 0110 0150 0220 0300
IN A 7.3 8.6 14.5 22 29 42 54 80 95
Imax A 11 12.9 21.8 33 43.5 63 81 120 143
Imax_CMP71-100 A 9.13 10.8 18.1 27.5 36.3 52.5 67.5 100 119
CMP40S Imax % IN 93.2
Mpk Nm 1.90
(lb in) (16.8)
CMP40M Imax % IN 129 129
Mpk Nm 3.30 3.65
(lb in) (29.2) (32.3)
CMP50S Imax % IN 129 129 127
Mpk Nm 3.58 4.05 5.20
(lb in) (31.7) (35.9) (46.1)
CMP50M Imax % IN 129 129 129 129 109
Mpk Nm 4.23 4.90 7.57 10.0 10.3
(lb in) (37.5) (43.4) (67.0) (88.6) (91.2)
CMP50L Imax % IN 129 129 129 129 129 108
Mpk Nm 4.08 4.77 7.72 11.0 13.4 15.4
(lb in) (36.1) (42.2) (68.4) (97.4) (119) (136)
CMP63S Imax % IN 129 129 129 129 129 96.9
Mpk Nm 4.04 4.65 7.05 9.29 10.7 11.1
(lb in) (35.8) (41.2) (62.4) (82.3) (94.8) (98.3)
CMP63M Imax % IN 129 129 129 129 129 129 129 90.4
Mpk Nm 4.38 5.11 8.21 11.7 14.5 18.5 21.1 21.4
(lb in) (38.8) (45.3) (72.7) (104) (128) (164) (187) (190)
CMP.71S Imax % IN 125 125 125 125 125 125
Mpk Nm 4.29 7.02 10.1 12.6 16.1 18.0
(lb in) (38.0) (62.2) (89.5) (112) (143) (159)
CMP.80S Imax % IN 125 125 125 125 125 125
Mpk Nm 10.2 13.5 19.6 24.8 33.4 36.6
(lb in) (90.3) (120) (174) (220) (296) (324)

19381212/EN – 03/2015

142 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 230 V system voltage 6
6.17 Dynamic and thermal characteristic curves, 230 V system voltage
For the maximum available torque, refer to Overview of combinations of CMP. with
MOVIDRIVE, 230 V system voltage (→ 2 138).
Definition:
• M = Maximum dynamic torque for a maximum line voltage on the inverter of 360 V,
400 V, 460 V or 500 V
6
• M S1 (derating) = thermal limit characteristic curve in S1 – 100% operation

Key:
M S1 M S1 thermal (derating)
DC 750 V controlled on DC 750 V constant
500 V 500 V line voltage, non-controlled
460 V 460 V line voltage, non-controlled
400 V 400 V line voltage, non-controlled
360 V 360 V line voltage, non-controlled

6.17.1 CMP40S 3000 rpm

2
230V

M S1

1.5
M [Nm]

0.5

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13827834635
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 143


6 Technical data of the motors
Dynamic and thermal characteristic curves, 230 V system voltage

6.17.2 CMP40S 4500 rpm

2
230V

M S1

1.5
M [Nm]

0.5

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13827836555

6.17.3 CMP40S 6000 rpm

230V
1.8
M S1
1.6

1.4

1.2
M [Nm]

0.8

0.6

0.4

0.2

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13827838475
19381212/EN – 03/2015

144 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 230 V system voltage 6
6.17.4 CMP40M 3000 rpm

230V
3.5
M S1

2.5
6
M [Nm]

1.5

0.5

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13827814155

6.17.5 CMP40M 4500 rpm

230V
3.5
M S1

2.5
M [Nm]

1.5

0.5

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13827816075
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 145


6 Technical data of the motors
Dynamic and thermal characteristic curves, 230 V system voltage

6.17.6 CMP40M 6000 rpm

230V
3.5
M S1

2.5
M [Nm]

1.5

0.5

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13827817995

6.17.7 CMP50S 3000 rpm

230V

5 M S1

4
M [Nm]

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13827867019
19381212/EN – 03/2015

146 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 230 V system voltage 6
6.17.8 CMP50S 4500 rpm

230V

5 M S1

6
M [Nm]

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13827868939

6.17.9 CMP50S 6000 rpm

230V

5 M S1

4
M [Nm]

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13827883659
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 147


6 Technical data of the motors
Dynamic and thermal characteristic curves, 230 V system voltage

6.17.10 CMP50M 3000 rpm

230V
10
M S1

8
M [Nm]

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13827860491

6.17.11 CMP50M 4500 rpm

230V
10
M S1

8
M [Nm]

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13827862411
19381212/EN – 03/2015

148 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 230 V system voltage 6
6.17.12 CMP50M 6000 rpm

230V
10
M S1

6
M [Nm]

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13827864331

6.17.13 CMP50L 3000 rpm

230V
14
M S1

12

10
M [Nm]

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13827841163
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 149


6 Technical data of the motors
Dynamic and thermal characteristic curves, 230 V system voltage

6.17.14 CMP50L 4500 rpm

230V
14
M S1

12

10
M [Nm]

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13827843083

6.17.15 CMP50L 6000 rpm

230V
14
M S1

12

10
M [Nm]

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13827857803
19381212/EN – 03/2015

150 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 230 V system voltage 6
6.17.16 CMP63S 3000 rpm

230V

10 M S1

6
M [Nm]

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13827897227

6.17.17 CMP63S 4500 rpm

230V

10 M S1

8
M [Nm]

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13827899147
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 151


6 Technical data of the motors
Dynamic and thermal characteristic curves, 230 V system voltage

6.17.18 CMP63S 6000 rpm

230V

10 M S1

M [Nm] 8

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13827901067

6.17.19 CMP63M 3000 rpm

230V
20
M S1

M S1, BK

15
M [Nm]

10

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13827890699
19381212/EN – 03/2015

152 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 230 V system voltage 6
6.17.20 CMP63M 4500 rpm

230V
20
M S1

M S1, BK

15
6
M [Nm]

10

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13827892619

6.17.21 CMP63M 6000 rpm

230V
20
M S1

M S1 /VR

15 M S1, BK
M [Nm]

10

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13827894539
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 153


6 Technical data of the motors
Dynamic and thermal characteristic curves, 230 V system voltage

6.17.22 CMP63L 3000 rpm

30 230V

M S1
25
M S1, BK

20
M [Nm]

15

10

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13827886347

6.17.23 CMP63L 4500 rpm

30 230V

M S1
25
M S1, BK

20
M [Nm]

15

10

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13827888267
19381212/EN – 03/2015

154 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 230 V system voltage 6
6.17.24 CMP71S 3000 rpm

20
230V

M S1

15 M S1 /VR

6
M [Nm]

10

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13827940235

6.17.25 CMP71S 4500 rpm

20
230V

M S1

15 M S1 /VR
M [Nm]

10

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13827942155
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 155


6 Technical data of the motors
Dynamic and thermal characteristic curves, 230 V system voltage

6.17.26 CMP71S 6000 rpm

20
230V

M S1

15 M S1 /VR
M [Nm]

10

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13827944075

6.17.27 CMP71M 3000 rpm

230V
30
M S1
25 M S1 /VR

20
M [Nm]

15

10

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13827908107
19381212/EN – 03/2015

156 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 230 V system voltage 6
6.17.28 CMP71M 4500 rpm

230V
30
M S1

25 M S1 /VR

20
6
M [Nm]

15

10

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13827935627

6.17.29 CMP71M 6000 rpm

230V
30
M S1
25

20
M [Nm]

15

10

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13827937547
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 157


6 Technical data of the motors
Dynamic and thermal characteristic curves, 230 V system voltage

6.17.30 CMP71L 3000 rpm

230V
45
M S1
40
M S1 /VR
35

30
M [Nm]

25

20

15

10

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13827903755

6.17.31 CMP71L 4500 rpm

50
230V

M S1
40

30
M [Nm]

20

10

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13827905675
19381212/EN – 03/2015

158 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 230 V system voltage 6
6.17.32 CMP80S 3000 rpm

230V
40
M S1
35
M S1 /VR
30

25
6
M [Nm]

20

15

10

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13827972619

6.17.33 CMP80S 4500 rpm

230V
40
M S1
35
M S1 /VR

30

25
M [Nm]

20

15

10

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13827974539
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 159


6 Technical data of the motors
Dynamic and thermal characteristic curves, 230 V system voltage

6.17.34 CMP80S 6000 rpm

230V
40
M S1
35
M S1 /VR
30

25
M [Nm]

20

15

10

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13827976459

6.17.35 CMP80M 3000 rpm

230V
60
M S1

50 M S1 /VR

40
M [Nm]

30

20

10

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13827953291
19381212/EN – 03/2015

160 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 230 V system voltage 6
6.17.36 CMP80M 4500 rpm

230V
60
M S1

50 M S1 /VR

40 6
M [Nm]

30

20

10

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13827955211

6.17.37 CMP80M 6000 rpm

230V
60
M S1

50

40
M [Nm]

30

20

10

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13827957131
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 161


6 Technical data of the motors
Dynamic and thermal characteristic curves, 230 V system voltage

6.17.38 CMP80L 3000 rpm

230V
100
M S1

M S1 /VR
80
M [Nm]

60

40

20

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13827946763

6.17.39 CMP80L 4500 rpm

230V
100
M S1

80
M [Nm]

60

40

20

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13827948683
19381212/EN – 03/2015

162 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 230 V system voltage 6
6.17.40 CMP80L 6000 rpm

230V
100
M S1

80

6
M [Nm]

60

40

20

0
0 1000 2000 3000 4000 5000 6000 7000
n [1/min]

13827950603

6.17.41 CMP100S 3000 rpm

70
230V

60 M S1

50

40
M [Nm]

30

20

10

0
0 500 1000 1500 2000 2500 3000 3500 4000 4500
n [1/min]

13827998475
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 163


6 Technical data of the motors
Dynamic and thermal characteristic curves, 230 V system voltage

6.17.42 CMP100S 4500 rpm

70
230V

60 M S1

50

40
M [Nm]

30

20

10

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13828000395

6.17.43 CMP100M 3000 rpm

230V
100
M S1

80
M [Nm]

60

40

20

0
0 500 1000 1500 2000 2500 3000 3500 4000 4500
n [1/min]

13827981323
19381212/EN – 03/2015

164 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Dynamic and thermal characteristic curves, 230 V system voltage 6
6.17.44 CMP100M 4500 rpm

230V
100
M S1

80

6
M [Nm]

60

40

20

0
0 1000 2000 3000 4000 5000 6000
n [1/min]

13827983243

6.17.45 CMP100L 3000 rpm

180 230V

160 M S1

140

120
M [Nm]

100

80

60

40

20

0
0 500 1000 1500 2000 2500 3000 3500 4000
n [1/min]

13827979147
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 165


6 Technical data of the motors
Torque/current characteristic curves

6.18 Torque/current characteristic curves


The following characteristic curves refer to non-ventilated motors and apply to a sys-
tem voltage of 230 V and 400 V.

6.18.1 CMP40S/M
6

[1]

4
M/M 0

[2]
3

0
0 1 2 3 4 5 6 7 8 9 10
I/I 0
4800432779

[1] CMP40M
[2] CMP40S

6.18.2 CMP50S/M/L
6

5
[1]

4 [2]
M/M 0

[3]
3

0
0 1 2 3 4 5 6 7 8
I/I 0
19381212/EN – 03/2015

4800435467

[1] CMP50L
[2] CMP50M
[3] CMP50S

166 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Torque/current characteristic curves 6
6.18.3 CMP63S/M/L
6

5
[1]
4
[2]
6
M/M 0
[3]
3

0
0 1 2 3 4 5 6 7 8
I/I 0
4800438155

[1] CMP63L
[2] CMP63M
[3] CMP63S

6.18.4 CMP.71S/M/L

4
[1]
3,5
[2]
3
[3]
2,5
M/M0

1,5

0,5

0
0 1 2 3 4 5 6 7
I/I0

4802079243

[1] CMP.71L
[2] CMP.71M
[3] CMP.71S
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 167


6 Technical data of the motors
Torque/current characteristic curves

6.18.5 CMP.80S/M/L

4,5
[1]
4

3,5
[2]
3
[3]
2,5

M/M0
2
1,5
1
0,5

0
0 1 2 3 4 5 6 7
I/I0
4802081931

[1] CMP.80L
[2] CMP.80M
[3] CMP.80S

6.18.6 CMP.100S/M/L

4,5
[1]
4
3,5
[2]
3
2,5
M/M0

[3]

1,5
1
0,5

0
0 1 2 3 4 5 6
I/I0

4802084619

[1] CMP.100L
[2] CMP.100M
[3] CMP.100S
19381212/EN – 03/2015

168 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Technical data of the motors
Torque/current characteristic curves 6
6.18.7 CMP112S/M/L/H/E
4,0

3,5 [5] [3]

[4]
3,0 [2]

[1]
2,5 6
M/M0
2,0

1,5

1,0

0,5

0,0
0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 4,5
I/I0
8923978507

[1] CMP112S [4] CMP112H


[2] CMP112M [5] CMP112E
[3] CMP112L
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 169


7 Dimension sheets for CMP. motors/brakemotors
Information about dimension sheets

7 Dimension sheets for CMP. motors/brakemotors


7.1 Information about dimension sheets

INFORMATION
As standard, the motors are supplied with smooth shaft end.
Shaft end with key is an optional design.

7.2 CMP40 S/M

19381212/EN – 03/2015

170 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP40 S/M 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 171


7 Dimension sheets for CMP. motors/brakemotors
CMP40 S/M

19381212/EN – 03/2015

172 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP40 S/M 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 173


7 Dimension sheets for CMP. motors/brakemotors
CMP50 S/M/L

7.3 CMP50 S/M/L

19381212/EN – 03/2015

174 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP50 S/M/L 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 175


7 Dimension sheets for CMP. motors/brakemotors
CMP50 S/M/L

19381212/EN – 03/2015

176 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP50 S/M/L 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 177


7 Dimension sheets for CMP. motors/brakemotors
CMP50 S/M/L

19381212/EN – 03/2015

178 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP50 S/M/L 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 179


7 Dimension sheets for CMP. motors/brakemotors
CMP63 S/M/L

7.4 CMP63 S/M/L

19381212/EN – 03/2015

180 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP63 S/M/L 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 181


7 Dimension sheets for CMP. motors/brakemotors
CMP63 S/M/L

19381212/EN – 03/2015

182 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP63 S/M/L 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 183


7 Dimension sheets for CMP. motors/brakemotors
CMP63 S/M/L

19381212/EN – 03/2015

184 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP63 S/M/L 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 185


7 Dimension sheets for CMP. motors/brakemotors
CMP.71 S/M/L

7.5 CMP.71 S/M/L

19381212/EN – 03/2015

186 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP.71 S/M/L 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 187


7 Dimension sheets for CMP. motors/brakemotors
CMP.71 S/M/L

19381212/EN – 03/2015

188 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP.71 S/M/L 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 189


7 Dimension sheets for CMP. motors/brakemotors
CMP.71 S/M/L

19381212/EN – 03/2015

190 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP.71 S/M/L 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 191


7 Dimension sheets for CMP. motors/brakemotors
CMP.71 S/M/L

19381212/EN – 03/2015

192 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP.71 S/M/L 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 193


7 Dimension sheets for CMP. motors/brakemotors
CMP.71 S/M/L

19381212/EN – 03/2015

194 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP.71 S/M/L 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 195


7 Dimension sheets for CMP. motors/brakemotors
CMP.71 S/M/L

19381212/EN – 03/2015

196 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP.71 S/M/L 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 197


7 Dimension sheets for CMP. motors/brakemotors
CMP.80 S/M/L

7.6 CMP.80 S/M/L

19381212/EN – 03/2015

198 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP.80 S/M/L 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 199


7 Dimension sheets for CMP. motors/brakemotors
CMP.80 S/M/L

19381212/EN – 03/2015

200 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP.80 S/M/L 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 201


7 Dimension sheets for CMP. motors/brakemotors
CMP.80 S/M/L

19381212/EN – 03/2015

202 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP.80 S/M/L 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 203


7 Dimension sheets for CMP. motors/brakemotors
CMP.80 S/M/L

19381212/EN – 03/2015

204 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP.80 S/M/L 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 205


7 Dimension sheets for CMP. motors/brakemotors
CMP.80 S/M/L

19381212/EN – 03/2015

206 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP.80 S/M/L 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 207


7 Dimension sheets for CMP. motors/brakemotors
CMP.80 S/M/L

19381212/EN – 03/2015

208 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP.80 S/M/L 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 209


7 Dimension sheets for CMP. motors/brakemotors
CMP.100 S/M/L

7.7 CMP.100 S/M/L

19381212/EN – 03/2015

210 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP.100 S/M/L 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 211


7 Dimension sheets for CMP. motors/brakemotors
CMP.100 S/M/L

19381212/EN – 03/2015

212 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP.100 S/M/L 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 213


7 Dimension sheets for CMP. motors/brakemotors
CMP.100 S/M/L

19381212/EN – 03/2015

214 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP.100 S/M/L 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 215


7 Dimension sheets for CMP. motors/brakemotors
CMP.100 S/M/L

19381212/EN – 03/2015

216 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP.100 S/M/L 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 217


7 Dimension sheets for CMP. motors/brakemotors
CMP.100 S/M/L

19381212/EN – 03/2015

218 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP.100 S/M/L 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 219


7 Dimension sheets for CMP. motors/brakemotors
CMP.100 S/M/L

19381212/EN – 03/2015

220 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP.100 S/M/L 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 221


7 Dimension sheets for CMP. motors/brakemotors
CMP112 S/M/L/H/E

7.8 CMP112 S/M/L/H/E

19381212/EN – 03/2015

222 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP112 S/M/L/H/E 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 223


7 Dimension sheets for CMP. motors/brakemotors
CMP112 S/M/L/H/E

19381212/EN – 03/2015

224 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP112 S/M/L/H/E 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 225


7 Dimension sheets for CMP. motors/brakemotors
CMP112 S/M/L/H/E

19381212/EN – 03/2015

226 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP112 S/M/L/H/E 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 227


7 Dimension sheets for CMP. motors/brakemotors
CMP112 S/M/L/H/E

19381212/EN – 03/2015

228 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP112 S/M/L/H/E 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 229


7 Dimension sheets for CMP. motors/brakemotors
CMP112 S/M/L/H/E

19381212/EN – 03/2015

230 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Dimension sheets for CMP. motors/brakemotors
CMP112 S/M/L/H/E 7

7
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 231


8 BK brakes
Description of BK brakes (CMP40 to CMP63)

8 BK brakes
8.1 Description of BK brakes (CMP40 to CMP63)
The mechanical brake is a holding brake implemented as a permanent magnet brake.
The standard voltage supply of the brake is DC 24 V, and it operates with a fixed brak-
ing torque per brake size.
The BK brake cannot be retrofitted and usually operates without brake rectifier or
brake control unit.
If servomotors are operated on the MOVIAXIS® servo inverter, overvoltage protection
is provided. If servomotors are operated on MOVIDRIVE® or inverters of other manu-
facturers, overvoltage protection must be implemented by the customers themselves
using varistors, for example.
Observe the notes in the relevant operating instructions for the inverters concerning
the switching sequence of motor enable and brake control during standard operation.
The BK brake can be used up to a rated speed of 6000 rpm.
The BK brake is a permanent magnet holding brake with emergency stop function. It is
different from the BP brakes through its fixed coil polarity.
The BK brake can be used for the following rated speeds depending on the motor
size:

Motor type Brake type Speed class


CMP40S/M BK01
CMP50S/M BK02
CMP63S BK03 3000 / 4500 / 6000
CMP50L BK04
CMP63L/M BK07

19381212/EN – 03/2015

232 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BK brakes
Principle of the BK brake 8
8.2 Principle of the BK brake
8.2.1 Basic design
The BK brake is a DC-operated permanent magnet brake that is released electrically
and is applied using the magnetic force of the permanent magnets.
The system meets all fundamental safety requirements: The brake is applied automat-
ically if the power fails.
Principle structure of the 24 V permanent magnet brake:

[1] [2]

8806784523

[1] Armature
[2] Complete brake
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 233


8 BK brakes
General information about BK brakes

8.2.2 Basic function


In de-energized condition, the pressure plate is forced against the magnet body by the
force of the permanent magnets. The motor is braked.
When the brake coil is energized with the corresponding DC voltage, the resulting
electromagnetic force cancels the force of the permanent magnets. Now the force of
the return spring pulls the pressure plate to the armature and in this way enables the
rotor to turn.
[5] [4] [2] [1] [3] [9]

[6]

[7]

[8]

[11]
[10]
[12]
9007208061126795

[1] Brake coil [7] Armature


[2] Permanent magnet [8] Motor shaft
[3] Magnet body [9] Endshield
[4] Pressure plate [10] Working air gap
[5] Return spring [11] Electromagnetic force and force of the
return spring
[6] Set screw [12] Permanent magnet force

8.3 General information about BK brakes


The size of the brakemotor and its electrical connection must be selected carefully to
ensure the longest possible service life.
The following aspects described in detail must be taken into account:
1. Selecting the braking torque according to the project planning data (→ 2 235).
2. Dimensioning and routing of the cable (→ 2 243).
3. Selecting the brake contactor (→ 2 243).
4. Important design information (→ 2 236).
19381212/EN – 03/2015

234 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BK brakes
Selecting the BK brake 8
8.4 Selecting the BK brake
The braking torque is determined when the drive motor is selected. The drive type, ap-
plication areas and the standards that have to be taken into account are also used for
brake selection.
If the application has to be held in place at standstill with the brake against external
forces (such as wind or press forces), then you have to take account of the specifica-
tions for hoists.
Selection criteria:
• Type of servomotor 8
• Amount of braking torque
The brake type is selected on the basis of the braking torque. For the assignment of
motor / brake type / braking torque, refer to chapter "Technical data of BK
brakes“ (→ 2 241).

8.4.1 Selecting the BK brake


The brake type is selected on the basis of the braking torque. For the assignment of
motor/brake type/braking torque, refer to chapter "Technical data of BK
brakes“ (→ 2 241).

8.4.2 Values determined / calculated during brake selection:

Basic specifica- Link/supplement/comment


tion
Motor type Brake type, brake control system
Braking torque The braking torque is determined from the requirements of the
application with regard to the maximum deceleration and the
maximum permitted distance or time, as well as to the permit-
ted braking work.
Brake application Type of brake control (important for electrical design, wiring dia-
time grams)
Braking time The required data can only be observed if the aforementioned
parameters meet the requirements
Braking distance
Deceleration
Braking accuracy

Selecting the brake


The brake suitable for the relevant application is selected by means of the following
main criteria:
• Required braking torque
19381212/EN – 03/2015

• Required working capacity

Braking torque
The braking torque is usually selected according to the required holding torque and
the required deceleration.
The nominal braking torque values of the BK brakes have been determined and
checked in accordance with DIN VDE 0580.

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 235


8 BK brakes
Important design information

Working capacity
The required working capacity of the brake is determined by the application parame-
ters and indicates the amount of braking energy the brake has to receive during a
braking operation.

INFORMATION
Application of the brake is no longer ensured if the permitted braking work per brak-
ing operation W1 is exceeded during deceleration from speed, or once the total per-
mitted braking work Winsp is reached. In this case, no braking occurs.

8.5 Important design information


8.5.1 EMC (electromagnetic compatibility)
The EMC instructions in the servo inverter documentation must also be taken into ac-
count for operating SEW servomotors with brake.
The instructions on laying cables (→ 2 243) must always be adhered to.

8.5.2 Maintenance intervals


The time to maintenance is determined on the basis of the expected brake wear. This
value is important for setting up the maintenance schedule for the machine to be used
by the customer’s service personnel (machine documentation).

19381212/EN – 03/2015

236 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BK brakes
BK brake project planning 8
8.6 BK brake project planning
8.6.1 Data for brake dimensioning
The data of the application must be known for projecting a brake. The abbreviations
used for project planning are summarized in the following table:

Designation Meaning Unit


ηG Efficiency of the gear unit
Jext External mass moment of inertia (in relation to motor shaft) kgm2
JMot Mass moment of inertia of the motor kgm2 8
M1max Maximum dynamic braking torque in case of emergency switching off Nm
M1m, 100 °C Minimal averaged dynamic braking torque in case of emergency switching off at Nm
100 °C
M2, 20 °C Nominal torque for slipping brake disk (relative speed between brake disk and Nm
friction surface: 1 m/s) at 20 °C
M4, 100 °C Minimum static braking torque (holding torque) at 100 °C Nm
MaEmergOff Maximum permitted emergency switching off torque of the gear unit Nm
i Gear unit reduction ratio
ML Static load torque, in relation to motor shaft Nm
n Motor speed rpm
nm Motor speed, from application or travel diagram rpm
nD Increase of motor speed until brake application rpm
nm EmergStop Real emergency stop speed, relevant for check rpm
sb Stopping distance mm
t2 Brake application time s
tB Braking time s
tr Response time or signal transmit time s
v Speed m/s
W1 Permitted braking work per braking operation J
W2 Permitted braking work per hour J
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 237


8 BK brakes
BK brake project planning

8.6.2 Hold function


The selected braking torque M4, 100 °C must at least be higher than the highest static
load torque of the application.

M 4,100 ° C > ML

8.6.3 Emergency switching off function for lifting applications


To ensure a deceleration of the load, for lifting applications, the lowest averaged dy-
namic braking torque M1m, 100 °C must be higher than the highest static load torque of
the application.

M1m,100 ° C > ML

8.6.4 Speed difference during brake application


Due to the interaction of response time (signal transmit time), brake application time
and the gravitational acceleration, the hoist may be in "free fall" for a short time. This
results in an increased motor speed by nD (hoist downwards) or in a decreased motor
speed by nD (horizontal drive and hoist upwards).
Calculating the emergency stop speed (hoist downwards):

nm,EmergencyStop = nm + nD

Calculating the emergency stop speed (horizontal drive and hoist upwards):

nm,EmergencyStop = nm − nD

9, 55 × ML × ( tr + t2 )
nD =
JMot + Jext × ηG

19381212/EN – 03/2015

238 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BK brakes
BK brake project planning 8
8.6.5 Working capacity in case of emergency switching off
Braking work per braking cycle in case of emergency switching off:

(JMot + Jext × ηG ) × nm,EmergStop2 × M1m,100°C


W1 =
182.4 × ( M1m,100°C ± ML )

Observe the sign of the highest static load torque ML in the formula. Use:

+ For vertical upward and horizontal movement


– For vertical downward movement 8
The calculated braking work W1 is compared with the permitted braking work per brak-
ing operation W1 of the BK brake (see "Technical data of BK brakes" (→ 2 241)).
According to the possible number of emergency switching off braking operations, it
must also be compared with the permitted braking work per hour W2 of the BK brake
(see "Technical data of BK brakes" (→ 2 241)).

W1(BKbrake ) > W1(calculated )

The following maximum permitted inertia ratios apply:

Motor type Brake type Permitted Jext / JMot


CMP40S/M BK01
without restrictions
CMP50S/M BK02
CMP63S BK03
Jext / JMot ≤ 30
CMP50L BK04
CMP63M/L BK07 Jext / JMot ≤ 20

Jext External mass moment of inertia in kgm2


JMot Mass moment of inertia of the motor in kgm2
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 239


8 BK brakes
BK brake project planning

8.6.6 Braking time / stopping distance

Braking time hoist downwards


(JMot + Jext × ηG ) × nm, EmergStop
tB =
9.55 × (M1m,100°C − ML )

Braking time horizontal drive, hoist upwards


(JMot + Jext × ηG ) × nm,EmergStop
tB =
9.55 × (M1m,100°C + ML )

Stopping distance
1
sb = v × 1000 × (t2 + tr + × tB )
2

8.6.7 Permitted gear unit load in case of emergency switching off


When using a gearmotor, in case of emergency switching off, the maximum dynamic
braking torque in case of emergency switching off M1max (see "Technical data of BK
brakes" (→ 2 241)) must not exceed the maximum permitted emergency switching off
torque MaEmergOff of the gear unit.
The value of the maximum permitted emergency switching off torque MaEmergOff is speci-
fied in the "Synchronous Servo Gearmotors" catalog.

MaEmergOff ≥ M1max ×i ×ηG

19381212/EN – 03/2015

240 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BK brakes
Technical data of BK brakes 8
8.7 Technical data of BK brakes
The following table shows the technical data of BK brakes. They operate with a fixed
braking torque per brake size.

Brake M4, 100 °C M1m, 100 °C M1max W1 W2 Winsp P t1 t2


type 3
Nm Nm Nm kJ kJ 10 kJ W ms ms
BK01 1.9 1.4 3.4 0.056 1.12 0.112 8.8 35 20
BK02 2.4 1.9 5.3 0.175 3.50 0.350 6.7 80 20
BK03 3.8 2.0 7.9 0.371 7.42 0.742 13.4 50 30 8
BK04 3.9 2.4 7.0 0.288 5.76 0.576 13.4 50 30
BK07 7.1 3.9 12.8 0.740 14.8 1.48 15.0 70 30

M4, 100 °C Minimum static braking torque (holding torque) at 100 °C


M1m, 100 °C Minimum averaged dynamic braking torque in case of emergency switching
off at 100 °C
M1max Maximum dynamic braking torque in case of emergency switching off
W1 Permitted braking work per braking operation
W2 Permitted braking work per hour
Winsp Permitted total braking work (braking work until maintenance)
P Power consumption of the coil
t1 Brake response time
t2 Brake application time

INFORMATION
The response and application times are guide values that were determined at maxi-
mum braking torque.
Possible response times of switching elements or controllers were not taken into ac-
count.

8.7.1 Motor assignment


The BK brake can be used for the following rated speeds and braking torques depend-
ing on the motor size:

Motor type Brake type M4, 100 °C Speed class


Nm
CMP40S/M BK01 1.9
CMP50S/M BK02 2.4
CMP63S BK03 3.8 3000 / 4500 / 6000
CMP50L BK04 3.9
CMP63M/L BK07 7.1
19381212/EN – 03/2015

M4, 100 °C Minimum static braking torque (holding torque) at 100 °C

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 241


8 BK brakes
Technical data of BK brakes

8.7.2 Operating currents for BK brakes

BK01 BK02 BK03 BK04 BK07


Braking torque M4, 100 °C in Nm 1.9 2.4 3.8 3.9 7.1
Braking power in W 8.8 6.7 13.4 13.4 15

Nominal voltage UN I I I I I
VDC ADC ADC ADC ADC ADC
24 (21.6 – 26.4) 0.365 0.280 0.557 0.557 0.623

M4, 100 °C Minimum static braking torque (holding torque) at 100 °C


I Operating current
UN Nominal voltage (nominal voltage range)
When dimensioning the 24 V supply, it is not necessary to consider a current reserve
for releasing the brake, i.e. the ratio of inrush current to operating current is 1.

8.7.3 Resistance values of BK brake coils

BK01 BK02 BK03 BK04 BK07


Braking torque M4, 100 °C in Nm 1.9 2.4 3.8 3.9 7.1
Braking power in W 8.8 6.7 13.4 13.4 15

Nominal voltage UN R R R R R
VDC Ω Ω Ω Ω Ω
24 (21.6 – 26.4) 65.7 85.5 43.1 43.1 38.6

M4, 100 °C Minimum static braking torque (holding torque) at 100 °C


R Coil resistance at 20 °C
VN Nominal voltage (nominal voltage range)

19381212/EN – 03/2015

242 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BK brakes
Dimensioning and routing of the cable 8
8.8 Dimensioning and routing of the cable
8.8.1 Selecting the cable
Select the cross section of the brake cable according to the currents in your applica-
tion. Note the inrush current of the brake when selecting the cross section. When tak-
ing the voltage drop into account due to the inrush current, the value must not drop
below 90% of the nominal voltage. The data sheets for the brakes provide information
on the possible supply voltages and the resulting operating currents.
Information about the size of the cable cross-section and the cable lengths can be
found in the "Cable assignments" (→ 2 344) tables.
8
Wire cross sections of max. 2.5 mm2 can be connected to the terminals of the
brake control systems. Intermediate terminals must be used if the cross sec-
tions are larger.

8.8.2 Routing information


Brake cables must always be routed separately from other power cables with
phased currents unless they are shielded.
Ensure adequate equipotential bonding between the drive and the control cabi-
net (for an example, see the documentation Drive Engineering – Practical Imple-
mentation "EMC in Drive Engineering").
Power cables with phased currents include in particular:
• Output cables from frequency inverters and servo inverters, soft start units and
brake units
• Incoming cables to braking resistors

8.9 Selecting the braking contactor


In view of the high current loading and the DC voltage to be switched at induc-
tive load, the switchgear for the brake voltage has to have a special DC contac-
tor.
Selecting the braking contactor for line operation is easy:
• The contactor is configured for DC3 operation with DC 24 V.
If the system complies with the specifications for direct brake control, then a BK brake
can also be controlled directly via the brake output of a MOVIAXIS® servo inverter.
Direct brake con- Specifications for direct brake control:
trol • Only BK brakes of the CMP40 to 63 and DS56 motor types are permitted.
• Expressly excluded are all brakes from third parties.
• Use only prefabricated brakemotor cables from SEW‑EURODRIVE.
• The brakemotor cable must be shorter than 25 m.
• Take into account all directly controlled brakes when selecting the 24 V supply for
19381212/EN – 03/2015

MOVIAXIS®.
• The 24 V supply of MOVIAXIS® must meet the requirements to ensure direct brake
control.

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 243


8 BK brakes
Block diagram of brake control – plug connectors

8.10 Block diagram of brake control – plug connectors


In every application, BK holding brakes can be controlled via the BMV brake relay or a
customer relay with varistor overvoltage protection.
In the following block diagrams, the contactor for the supply voltage of the brake recti-
fier is designated as K12.
The following applies to BMV: In applications without requirements on functional safe-
ty, the brake need only be connected via connections 3 and 4 (depicted as N.O. con-
tact without name). In applications with requirements on functional safety (such as
hoists), all poles must be switched off to ensure that the brake is applied even in the
event of a fault in the brake rectifier.

8.10.1 BMV brake controller


BMV

13
14
15
1
2
3
4

SB1

D 3
K12 C

4
+ -
DC 24 V + - B
U IN
A 1
DC 24 V
12986554123

Connection 1, 2 Power supply


Connection 3, 4 Signal (inverter)

8.10.2 BS brake contactor

BS

1 2 3 4 5 SB1

D 3
C

B
A 1
- +
24 VDC

12986690059
19381212/EN – 03/2015

244 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BK brakes
Block diagram of brake control – plug connectors 8
8.10.3 Direct 24 V brake supply

24 VDC
- +

SB1

D 3
C

B
8
A 1

12986696203

In the following cases, the brake must be protected from overvoltage, for example by
means of a varistor protection circuit:
• Operation on non-SEW inverters,
• If the brake is not directly supplied from the SEW inverter.
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 245


8 BK brakes
Block diagram of brake control – terminal box

8.11 Block diagram of brake control – terminal box


In the following block diagrams, the contactor for the supply voltage of the brake recti-
fier is designated as K12. Except for BMV, BMKB and BMK, it is used to also switch
the brake.
BMV and BMK: In applications without requirements on functional safety, the brake
need only be connected via connections 3 and 4 (depicted as N.O. contact without
name). In applications with requirements on functional safety (such as hoists), all
poles must be switched off to ensure that the brake is applied even in the event of a
fault in the brake rectifier.

8.11.1 BMV brake controller – CMP50, CMP63


BMV
13
14
15
1
2
3
4

4a 5a 10 9 8 7 6 5 4 3 2 1
PE W V U

K12

+ -
24 VDC + -
24 VDC
9007202156467339

Connection 1, 2 Power supply


Connection 3, 4 Signal (inverter)

8.11.2 BS brake contactor – CMP50, CMP63

BS

1 2 3 4 5

4a 5a 10 9 8 7 6 5 4 3 2 1
PE W V U

- +
24 VDC
9007202156472715
19381212/EN – 03/2015

246 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BK brakes
Dimensions drawings for BK brake controls 8
8.12 Dimensions drawings for BK brake controls
8.12.1 BMV
For information regarding the use of the BMV brake control, refer to chapter "Block di-
agram of brake control" (→ 2 244).
1)

BM. ...
1
2 8
3
75

13
14
15

22.5 5 68

91.5
4809803019

1) Support rail mounting according to EN 50022‑35‑7.5 (not included in the delivery)


19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 247


9 BP brakes
Description of BP brakes (CMP71 to CMP100)

9 BP brakes
9.1 Description of BP brakes (CMP71 to CMP100)
The mechanical brake is a holding brake implemented as a spring-loaded brake.
The brake has a standard supply voltage of DC 24 V and operates with one or two
braking torque ratings for each motor size (→ 2 256).
The brake cannot be retrofitted and usually operates without brake rectifier or brake
control unit.
If servomotors are operated on the MOVIAXIS® servo inverter, overvoltage protection
is provided.
If servomotors are operated on MOVIDRIVE® or inverters of other manufacturers,
overvoltage protection must be implemented by the customers themselves using va-
ristors, for example.
Observe the notes in the relevant operating instructions for the inverters concerning
the switching sequence of motor enable and brake control during standard operation.
The BP brake can be used for the following rated speeds depending on the motor
size:

Motor type Brake type Speed class


CMP71S/M/L BP1 2000 / 3000 / 4500 / 6000
CMP80S/M/L BP3
2000 / 3000 / 4500
CMP100S/M/L BP5

19381212/EN – 03/2015

248 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BP brakes
Principle of the BP brake 9
9.2 Principle of the BP brake
9.2.1 Basic design
The SEW brake is an electromagnetic disk brake with a DC coil that releases electri-
cally and brakes using spring force.
The system meets all fundamental safety requirements: the brake is applied if the
power fails.
Principle structure of the 24 V spring-loaded brake:

9
[1] [2]

4809267211

[1] Driver
[2] Complete brake
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 249


9 BP brakes
General information about BP brakes

9.2.2 Basic function


The pressure plate is forced against the brake disk by the brake springs when the
electromagnet is de-energized. The brake is applied to the motor. The number and
type of brake springs determine the braking torque. When the brake coil is connected
to the corresponding DC voltage, the force of the brake springs [4] is overcome by
magnetic force [11], thereby bringing the pressure plate into contact with the magnet.
The brake disk moves clear and the rotor can turn.
[1] [6]

[2]
[8]

[3] [9]

[10]

[11]

[7]

[4] [5]

4809269899

[1] Brake disk [7] Brake spring


[2] Brake endshield [8] Brake coil
[3] Driver [9] Magnet body
[4] Spring force [10] Motor shaft
[5] Working air gap [11] Electromagnetic force
[6] Pressure plate

9.3 General information about BP brakes


The size of the brakemotor and its electrical connection must be selected carefully to
ensure the longest possible service life.
The following aspects described in detail must be taken into account:
1. Selecting the braking torque according to the project planning data (→ 2 251).
2. Dimensioning and routing of the cable (→ 2 259).
19381212/EN – 03/2015

3. Selecting the brake contactor (→ 2 259).


4. Important design information (→ 2 252).

250 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BP brakes
Selecting the BP brake 9
9.4 Selecting the BP brake
The braking torque is determined when the drive motor is selected. The drive type, ap-
plication areas and the standards that have to be taken into account are also used for
brake selection.
If the application has to be held in place at standstill with the brake against external
forces (such as wind or press forces), then you have to take account of the specifica-
tions for hoists.
Selection criteria:
• Type of servomotor
• Amount of the braking torque
9
The brake type is selected on the basis of the braking torque. For the assignment of
motor / brake type / braking torque, refer to chapter "Technical data of BP
brakes" (→ 2 256).

9.4.1 Selecting the BP brake


The brake type is selected on the basis of the braking torque. For the assignment of
motor / brake type / braking torque, refer to chapter "Technical data of BP
brakes" (→ 2 256).

9.4.2 Values determined / calculated during brake selection:

Basic specifica- Link/supplement/comment


tion
Motor type Brake type, brake control system
Braking torque The braking torque is determined from the requirements of the
application with regard to the maximum deceleration and the
maximum permitted distance or time, as well as to the permit-
ted braking work.
Brake application Type of brake control (important for electrical design, wiring dia-
time grams)
Braking time The required data can only be observed if the aforementioned
parameters meet the requirements
Braking distance
Deceleration
Braking accuracy

Selecting the brake


The brake suitable for the relevant application is selected by means of the following
main criteria:
• Required braking torque
19381212/EN – 03/2015

• Required working capacity

Braking torque
The braking torque is usually selected according to the required holding torque and
the required deceleration.
The nominal braking torque values of the BP brakes have been determined and
checked in accordance with DIN VDE 0580.

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 251


9 BP brakes
Important design information

Working capacity
The required working capacity of the brake is determined by the application parame-
ters and indicates the amount of braking energy the brake has to receive during a
braking operation.

INFORMATION
Application of the brake is no longer ensured if the permitted braking work per brak-
ing operation W1 is exceeded during deceleration from speed, or once the total per-
mitted braking work Winsp is reached. In this case, no braking occurs.

9.5 Important design information


9.5.1 EMC (electromagnetic compatibility)
The EMC instructions in the servo inverter documentation must also be taken into ac-
count for operating SEW servomotors with brake.
The instructions on laying cables (→ 2 259) must always be adhered to.

9.5.2 Maintenance intervals


The time to maintenance is determined on the basis of the expected brake wear. This
value is important for setting up the maintenance schedule for the machine to be used
by the customer’s service personnel (machine documentation).

19381212/EN – 03/2015

252 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BP brakes
BP brake project planning 9
9.6 BP brake project planning
9.6.1 Data for brake dimensioning
The data of the application must be known for projecting a brake. The abbreviations
used for project planning are summarized in the following table:

Designation Meaning Unit


ηG Efficiency of the gear unit
Jext External mass moment of inertia (in relation to motor shaft) kgm2
JMot Mass moment of inertia of the motor kgm2
M1max Maximum dynamic braking torque in case of emergency switching off Nm 9
M1m, 100 °C Minimal averaged dynamic braking torque in case of emergency switching off at Nm
100 °C
M2, 20 °C Nominal torque for slipping brake disk (relative speed between brake disk and Nm
friction surface: 1 m/s) at 20 °C
M4, 100 °C Minimum static braking torque (holding torque) at 100 °C Nm
MaEmergOff Maximum permitted emergency switching off torque of the gear unit Nm
i Gear unit reduction ratio
ML Static load torque, in relation to motor shaft Nm
n Motor speed rpm
nm Motor speed, from application or travel diagram rpm
nD Increase of motor speed until brake application rpm
nm EmergStop Real emergency stop speed, relevant for check rpm
sb Stopping distance mm
t2 Brake application time s
tB Braking time s
tr Response time or signal transmit time s
v Speed m/s
W1 Permitted braking work per braking operation J
W2 Permitted braking work per hour J
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 253


9 BP brakes
BP brake project planning

9.6.2 Hold function


The selected braking torque M4, 100 °C must at least be higher than the highest static
load torque of the application.

M 4,100 ° C > ML

The following table shows the number of permitted switching cycles of the BP brake
until end of service life when used exclusively as holding brake.

Motor type Brake type Permitted switching cycles


CMP71 BP1 4,000,000
CMP80 BP3 2,500,000
CMP100 BP5 1,500,000

9.6.3 Emergency switching off function for lifting applications


To ensure a deceleration of the load, for lifting applications, the lowest averaged dy-
namic braking torque M1m, 100 °C must be higher than the highest static load torque of
the application.

M1m,100 ° C > ML × 1.2

9.6.4 Speed difference during brake application


Due to the interaction of response time (signal transmit time), brake application time
and the gravitational acceleration, the hoist may be in "free fall" for a short time. This
results in an increased motor speed by nD (hoist downwards) or in a decreased motor
speed by nD (horizontal drive and hoist upwards).
Calculating the emergency stop speed (hoist downwards):

nm,EmergencyStop = nm + nD

Calculating the emergency stop speed (horizontal drive and hoist upwards):

nm,EmergencyStop = nm − nD

9, 55 × ML × ( tr + t2 )
nD =
JMot + Jext × ηG
19381212/EN – 03/2015

254 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BP brakes
BP brake project planning 9
9.6.5 Working capacity in case of emergency switching off
Braking work per braking cycle in case of emergency switching off:

(JMot + Jext × ηG ) × nm,EmergStop2 × M1m,100°C


W1 =
182.4 × ( M1m,100°C ± ML )

Observe the sign of the highest static load torque ML in the formula. Use:

+ For vertical upward and horizontal movement


– For vertical downward movement
The calculated braking work W1 is compared with the permitted braking work per brak-
9
ing operation W1 of the BP brake (see "Technical data of BP brakes" (→ 2 256)).
According to the possible number of emergency switching off braking operations, it
must also be compared with the permitted braking work per hour W2 of the BP brake
(see "Technical data of BP brakes (→ 2 256)).

W1( BPbrake ) > W1(calculated )

9.6.6 Braking time / stopping distance

Braking time hoist downwards


(JMot + Jext × ηG ) × nm, EmergStop
tB =
9.55 × (M1m,100°C − ML )

Braking time horizontal drive, hoist upwards


(JMot + Jext × ηG ) × nm,EmergStop
tB =
9.55 × (M1m,100°C + ML )

Stopping distance
1
sb = v × 1000 × (t2 + tr + × tB )
2

9.6.7 Permitted gear unit load in case of emergency switching off


When using a gearmotor, in case of emergency switching off , the maximum dynamic
braking torque in case of emergency switching off M1max (see "Technical data of BK
brakes" (→ 2 241)) must not exceed the maximum permitted emergency switching off
torque MaEmergOff of the gear unit.
The value of the maximum permitted emergency switching off torque MaEmergOff is speci-
fied in the "Synchronous Servo Gearmotors" catalog.
19381212/EN – 03/2015

MaEmergOff ≥ M2, 20°C × i × ηG

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 255


9 BP brakes
Technical data of BP brakes

9.7 Technical data of BP brakes


The following table shows the technical data of the brakes. The type and number of
brake springs determines the level of the braking torque. If not specified otherwise in
the order, brakemotors are delivered with the braking torques indicated with gray
background.

Motor type Brake M2, 20 °C M4, 100 °C M1m, 100 °C W1 W2 Winsp P t1 t2


type 3
Nm Nm Nm kJ kJ 10 kJ W ms ms
CMP71S BP1 7 4.2 2.8 1.4 16.8 2.6 19.5 200 75
14 8.4 5.6
CMP71M/L BP1 7 4.2 2.8 1.4 16.8 2.6 19.5 200 75
14 8.4 5.6
CMP80S BP3 16 9.6 6.4 2.2 26.4 4.1 28 200 75
31 18.6 12.4
CMP80M/L BP3 16 9.6 6.4 2.2 26.4 4.1 28 200 75
31 18.6 12.4
CMP100S BP5 24 14.4 9.6 3.6 43.2 6.7 33 200 75
47 28.2 18.8
CMP100M/L BP5 24 14.4 9.6 3.6 43.2 6.7 33 200 75
47 28.2 18.8

Standard braking torque


Optional braking torque
M2, 20 °C Nominal torque for slipping brake disk (relative speed between brake disk
and friction surface: 1 m/s) at 20 °C
M4, 100 °C Minimum static braking torque (holding torque) at 100 °C
M1m, 100 °C Minimum averaged dynamic braking torque in case of emergency switching
off at 100 °C
W1 Permitted braking work per braking operation
W2 Permitted braking work per hour
Winsp Permitted total braking work (braking work until maintenance)
P Power consumption of the coil
t1 Brake response time
t2 Brake application time

INFORMATION
The response and application times are guide values that were determined at maxi-
mum braking torque.
Possible response times of switching elements or controllers were not taken into ac-
count.
19381212/EN – 03/2015

256 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BP brakes
Technical data of BP brakes 9
9.7.1 Motor assignment
The BP brake can be used for the following rated speeds and braking torques depend-
ing on the motor size:

Motor type Brake type M2, 20 °C Speed class


Nm
CMP71S 7 14 2000 / 3000 / 4500 /
BP1
CMP71M/L 7 14 6000

CMP80S 16 31
BP3 2000 / 3000 / 4500
CMP80M/L 16 31 9
CMP100S 24 47
BP5 2000 / 3000 / 4500
CMP100M/L 24 47

M2, 20 °C Nominal torque for slipping brake disk (relative speed between brake disk
and friction surface: 1 m/s) at 20 °C
Standard braking torque
Optional braking torque

9.7.2 Operating currents for BP brakes

BP1 BP3 BP5


Braking torque M2, 20 °C in Nm 14 31 47
Braking power in W 19.5 28 33

Nominal voltage UN I I I
VDC ADC ADC ADC
24 (21.6 – 26.4) 0.81 1.17 1.38

M2, 20 °C Nominal torque for slipping brake disk (relative speed between brake disk
and friction surface: 1 m/s) at 20 °C
I Operating current
UN Nominal voltage (nominal voltage range)
When dimensioning the 24 V supply, it is not necessary to consider a current reserve
for releasing the brake, i.e. the ratio of inrush current to operating current is 1.
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 257


9 BP brakes
Technical data of BP brakes

9.7.3 Resistance values of BP brake coils

BP1 BP3 BP5


Braking torque M2, 20 °C in Nm 14 31 47
Braking power in W 19.5 28 33

Nominal voltage UN R R R
VDC Ω Ω Ω
24 (21.6 – 26.4) 29.4 20.5 17.3

M2, 20 °C Nominal torque for slipping brake disk (relative speed between brake disk
and friction surface: 1 m/s) at 20 °C
R Coil resistance at 20 °C
VN Nominal voltage (nominal voltage range)

9.7.4 Permitted switching work (emergency switching off operation)


The permitted number of switching cycles per hour is 10.
The minimum pause time between 2 switching cycles is 6 minutes.

19381212/EN – 03/2015

258 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BP brakes
Dimensioning and routing of the cable 9
9.8 Dimensioning and routing of the cable
9.8.1 Selecting the cable
Select the cross section of the brake cable according to the currents in your applica-
tion. Note the inrush current of the brake when selecting the cross section. When tak-
ing the voltage drop into account due to the inrush current, the value must not drop
below 90% of the nominal voltage. The data sheets for the brakes provide information
on the possible supply voltages and the resulting operating currents.
Information about the size of the cable cross-section and the cable lengths can be
found in the "Cable assignments" (→ 2 344) tables.
Wire cross sections of max. 2.5 mm2 can be connected to the terminals of the
brake control systems. Intermediate terminals must be used if the cross sec-
9
tions are larger.

9.8.2 Routing information


Brake cables must always be routed separately from other power cables with
phased currents unless they are shielded.
Ensure adequate equipotential bonding between the drive and the control cabi-
net (for an example, see the documentation Drive Engineering – Practical Imple-
mentation "EMC in Drive Engineering").
Power cables with phased currents include in particular:
• Output cables from frequency inverters and servo inverters, soft start units and
brake units
• Incoming cables to braking resistors

9.9 Selecting the braking contactor


In view of the high current loading and the DC voltage to be switched at induc-
tive load, the switchgear for the brake voltage has to have a special DC contac-
tor.
Selecting the braking contactor for line operation is easy:
• The contactor is configured for DC3 operation with DC 24 V.
If the system complies with the specifications for direct brake control, then a BP brake
can also be controlled directly via the brake output of a MOVIAXIS® servo inverter.
However, the brakes of CMP80 and CMP100 motors can never be directly connected
to MOVIAXIS®. For detailed information, refer to the "MOVIAXIS® Multi-Axis Servo In-
verter" system manual.
Direct brake con- Specifications for direct brake control:
trol • Only BP brakes of the CMP71 motor type is permitted.
• Expressly excluded are brakes of the motor types CMP80 and greater, CMPZ mo-
tors, and all non-SEW brakes.
19381212/EN – 03/2015

• Only prefabricated brakemotor cables from SEW‑EURODRIVE must be used.


• The brakemotor cable must be shorter than 25 m.
• When dimensioning the 24 V supply of MOVIAXIS®, all directly controlled brakes
must be considered.
• The 24 V supply of MOVIAXIS® must meet the requirements to ensure direct brake
control.

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 259


9 BP brakes
Block diagram of brake control – plug connectors

9.10 Block diagram of brake control – plug connectors


In every application, BP holding brakes can be controlled via the BMV brake relay or a
customer relay with varistor overvoltage protection.
In the following block diagrams, the contactor for the supply voltage of the brake recti-
fier is designated as K12.
The following applies to BMV: In applications without requirements on functional safe-
ty, it is sufficient to switch the brake via connections 3 and 4 (depicted as N.O. contact
without name). In applications with requirements on functional safety (such as hoists),
all poles must be switched off to ensure that the brake is applied even in the event of a
fault in the brake rectifier.

9.10.1 BMV brake controller


BMV BMV

13
14
13
14

15
15

1
2
3
4
1
2
3
4

SB1 SBB

D 3
V
K12 C K12
- +
4 W U

DC 24 V + - B DC 24 V + - 1
U IN U IN 2
A 1
DC 24 V DC 24 V

9007202156330251

Connection 1, 2 Power supply


Connection 3, 4 Signal (inverter)

9.10.2 BS brake contactor

BS BS

1 2 3 4 5 SB1 1 2 3 4 5

D 3
SBB
C

4 V
- +
B
W U
A 1
- + - +
1
24 VDC 24 VDC
2
19381212/EN – 03/2015

2901591947

260 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BP brakes
Block diagram of brake control – plug connectors 9
9.10.3 Direct 24 V brake supply
24 VDC 24 VDC
- + - +

SB1 SBB

D 3
V
C
- +
4 W U

1
B
2
A 1

9007202156335627 9
In the following cases, the brake must be protected from overvoltage, for example by
means of a varistor protection circuit:
• Operation on non-SEW inverters,
• If the brake is not directly supplied from the SEW inverter.
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 261


9 BP brakes
Block diagram of brake control – terminal box

9.11 Block diagram of brake control – terminal box


In the following block diagrams, the contactor for the supply voltage of the brake recti-
fier is designated as K12. Except for BMV, BMKB and BMK, it is used to also switch
the brake.
BMV and BMK: In applications without requirements on functional safety, it is sufficient
to switch the brake via connections 3 and 4 (depicted as N.O. contact without name).
In applications with requirements on functional safety (such as hoists), all poles must
be switched off to ensure that the brake is applied even in the event of a fault in the
brake rectifier.

9.11.1 BMV brake controller

2901729035

Connection 1, 2 Power supply


Connection 3, 4 Signal (inverter)

9.11.2 BS brake contactor

BS

1 2 3 4 5
3a
4a
5a

1
2
3
4
- + 5
24 VDC 6
7
8
9
10

9007202156475403
19381212/EN – 03/2015

262 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BP brakes
Dimension drawings for BP brake controls 9
9.12 Dimension drawings for BP brake controls
9.12.1 BMV
For information regarding the use of the BMV brake control, refer to chapter "Block di-
agram of brake control" (→ 2 260).
1)

BM. ...
1
2
3 9
75

13
14
15

22.5 5 68

91.5
4809803019

1) Support rail mounting according to EN 50022‑35‑7.5 (not included in the delivery)


19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 263


10 BY brakes
Description of BY brakes (CMPZ71 to CMPZ100, CMP112)

10 BY brakes
10.1 Description of BY brakes (CMPZ71 to CMPZ100, CMP112)
On request, SEW‑EURODRIVE motors can be supplied with an integrated mechanical
brake. The brake is a DC-operated electromagnetic disk brake with a high working ca-
pacity that is released electrically and is applied using spring force. The brake is ap-
plied in case of a power failure. It meets the basic safety requirements.
The brake can also be released mechanically if equipped with manual brake release.
The manual brake release function is self-reengaging (..HR). A hand lever is supplied.
The /HR manual brake release option in combination with a /VR forced cooling fan is
only available for CMP112.
The brake is controlled by a brake controller that is either installed in the control cabi-
net or in the terminal box.
A main advantage of brakes from SEW‑EURODRIVE is their very short design. The
integrated construction of the brakemotor permits particularly compact and sturdy sol-
utions.
Observe the notes in the relevant operating instructions concerning the switching se-
quence of motor enable and brake control during standard operation.
The BY brake can be used for the following rated speeds depending on the motor
size:

Motor type Brake type Speed class


CMPZ71S/M/L BY2 2000 / 3000 / 4500 / 6000
CMPZ80S/M/L BY4
CMPZ100S/M/L BY8 2000 / 3000 / 4500
CMP112S/M/L/H/E BY14

19381212/EN – 03/2015

264 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BY brakes
Principle of the BY brake 10
10.2 Principle of the BY brake
10.2.1 Basic function
The pressure plate is forced against the brake disk by the brake springs when the
electromagnet is de-energized. The brake is applied to the motor. The number and
type of brake springs determine the braking torque. When the brake coil is connected
to the corresponding DC voltage, the force of the brake springs is overcome by mag-
netic force, thereby bringing the pressure plate into contact with the magnet. The
brake disk moves clear and the rotor can turn.
Basic structure of the working brake:

10
[5]
[1] [2] [3] [4]

[6]

4810006155

[1] Additional flywheel mass [4] Complete magnet body


[2] Brake disk [5] Releasing lever
[3] Pressure plate [6] RH1M encoder

10.3 General information


The BY working brake can be mounted on CMPZ71 to CMPZ100 motors (motor de-
sign with additional flywheel mass) and on CP112 motors.
The size of the brakemotor and its electrical connection must be selected carefully to
ensure the longest possible service life.
The following aspects described in detail must be taken into account:
1. Selecting the braking torque according to the project planning data (→ 2 266).
19381212/EN – 03/2015

2. Dimensioning and routing of the cable (→ 2 283).


3. Selecting the brake contactor (→ 2 283).
4. Important design information (→ 2 267).

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 265


10 BY brakes
Selecting the BY brake

10.4 Selecting the BY brake


The mechanical components, brake type and braking torque are determined when the
drive motor is selected. The drive type or application areas and the standards that
have to be taken into account are used for the brake selection.
Selection criteria:
• Servomotor motor size
• Number of braking operations during service and number of emergency braking
operations
• Working brake or holding brake
• Level of braking torque ("soft braking"/"hard braking")
• Hoist application
• Minimum/maximum deceleration
• Encoder system used
The brake type is selected on the basis of the braking torque. For the assignment of
motor/brake type/braking torque, refer to chapter "Technical data of BY
brakes" (→ 2 273).

10.4.1 Selecting the BY brake


The brake type is selected on the basis of the braking torque. For the assignment of
motor / brake type / braking torque, refer to chapter "Technical data of BY
brakes" (→ 2 273).

10.4.2 Values determined / calculated during brake selection:

Basic specifica- Link/supplement/comment


tion
Motor type Brake type, brake control system
Braking torque The braking torque is determined from the requirements of the
application with regard to the maximum deceleration and the
maximum permitted distance or time, as well as to the permit-
ted braking work.
Brake application Type of brake control (important for electrical design, wiring dia-
time grams)
Braking time The required data can only be observed if the aforementioned
parameters meet the requirements
Braking distance
Deceleration
Braking accuracy
19381212/EN – 03/2015

266 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BY brakes
Important design information 10
Selecting the brake
The brake suitable for the relevant application is selected by means of the following
main criteria:
• Required braking torque
• Required working capacity

Braking torque
The braking torque is usually selected according to the required holding torque and
the required deceleration.
Detailed motor data can be found in chapter "Technical data of BY brakes" (→ 2 273).
The nominal braking torque values of BY brakes have been determined and checked 10
in accordance with DIN VDE 0580.

Working capacity
The required working capacity of the brake is determined by the application parame-
ters and indicates the amount of braking energy the brake has to receive during a
braking operation.

INFORMATION
Application of the brake is no longer ensured if the permitted braking work per brak-
ing operation W1 is exceeded during deceleration from speed, or once the total per-
mitted braking work Winsp is reached. In this case, no braking occurs.

10.5 Important design information


10.5.1 EMC (electromagnetic compatibility)
The EMC instructions in the servo inverter documentation must also be taken into ac-
count for operating SEW servomotors with brake.
The instructions on laying cables (→ 2 283) must always be adhered to.

10.5.2 Maintenance intervals


The time to maintenance is determined on the basis of the expected brake wear. This
value is important for setting up the maintenance schedule for the machine to be used
by the customer’s service personnel (machine documentation).
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 267


10 BY brakes
BY brake project planning

10.6 BY brake project planning


10.6.1 Data for brake dimensioning
The data of the application must be known for projecting a brake. The abbreviations
used for project planning are summarized in the following table:
The data of the application must be known for projecting a brake. The abbreviations
used for project planning are summarized in the following table:

Designation Meaning Unit


ηG Efficiency of the gear unit
Jext External mass moment of inertia (in relation to motor shaft) kgm2
JMot Mass moment of inertia of the motor kgm2
M1max Maximum dynamic braking torque in case of emergency switching off Nm
M1m, 100 °C Minimal averaged dynamic braking torque in case of emergency switching off at Nm
100 °C
M2, 20 °C Nominal torque for slipping brake disk (relative speed between brake disk and Nm
friction surface: 1 m/s) at 20 °C
M4, 100 °C Minimum static braking torque (holding torque) at 100 °C Nm
MaEmergOff Maximum permitted emergency switching off torque of the gear unit Nm
i Gear unit reduction ratio
ML Static load torque, in relation to motor shaft Nm
n Motor speed rpm
nm Motor speed, from application or travel diagram rpm
nD Increase of motor speed until brake application rpm
nm EmergStop Real emergency stop speed, relevant for check rpm
NB Number of braking operations until maintenance
sb Stopping distance mm
t2 Brake application time s
tB Braking time s
tr Response time or signal transmit time s
v Speed m/s
W1 Permitted braking work per braking operation J
Winsp Permitted total braking work (braking work until maintenance) J
19381212/EN – 03/2015

268 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BY brakes
BY brake project planning 10
10.6.2 Hold function
The selected braking torque M4, 100 °C must at least be higher than the highest static
load torque of the application.

M 4,100 ° C > ML

10.6.3 Emergency switching off function for lifting applications


To ensure a deceleration of the load, for lifting applications, the lowest averaged dy-
namic braking torque M1m, 100 °C must be higher than the highest static load torque of
the application.

M1m,100 ° C > ML × 1.4 10

10.6.4 Speed difference during brake application


Due to the interaction of response time (signal transmit time), brake application time
and the gravitational acceleration, the hoist may be in "free fall" for a short time. This
results in an increased motor speed by nD (hoist downwards) or in a decreased motor
speed by nD (horizontal drive and hoist upwards).
Calculating the emergency stop speed (hoist downwards):

nm,EmergencyStop = nm + nD

Calculating the emergency stop speed (horizontal drive and hoist upwards):

nm,EmergencyStop = nm − nD

9, 55 × ML × ( tr + t2 )
nD =
JMot + Jext × ηG
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 269


10 BY brakes
BY brake project planning

10.6.5 Working capacity in case of emergency switching off


The working capacity of the brake is determined by the permitted braking work done
W1 per braking operation and the total permitted braking work Winsp until maintenance
of the brake.
You find the total permitted braking work Winsp in chapter "Technical data of BY
brakes".
Permitted number of braking operations until maintenance of the brake:

Winsp
NB =
W1

Braking work per braking operation:

(JMot + Jext × ηG ) × nm,EmergStop2 × M1m,100°C


W1 =
182.4 × ( M1m,100°C ± ML )

The calculated braking work W1 is compared with the permitted braking work per brak-
ing operation W1 of the BY brake (see "Technical data of BY brakes" (→ 2 273)).

W1(BYbrake ) > W1(calculated)

19381212/EN – 03/2015

270 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BY brakes
BY brake project planning 10
10.6.6 Emergency switching off features
The limits of the permitted maximum braking work must not be exceeded, not even for
emergency switching off.
The emergency switching off features are based on the directions of movement.
1. Braking during vertical movement
In hoist applications, the limits of the permitted maximum braking work (including
emergency switching off) must not be exceeded.
Consult SEW‑EURODRIVE if you need values for increased emergency switching
off braking work in hoist applications.
2. Braking during horizontal movement
For horizontal motion like in travel drive applications, higher braking work might be 10
permitted per cycle in emergency stop situations under the following conditions.
• Selected braking torque
All braking torques are permitted (unlike BE.. brakes of DR.. series AC motors).
• Brake wear
The specific wear of the brake lining increases significantly in case of an emer-
gency stop. It can reach a factor of 100 under certain circumstances.
This additional wear must be taken into account when determining the mainte-
nance cycle.
• Braking process
During the braking process, the effective dynamic braking torque can be re-
duced due to the heating of the brake lining during braking. In extreme cases,
the effective braking torque can be reduced up to 80% of M1m,100°C. Take this into
account when you determine the braking distance.
Example: BY8 with M1m,100°C = 56 Nm, minimal effective 80%
M1m, 100 °C = 44.8 Nm
• Braking speed
Consult SEW‑EURODRIVE if you need values for increased emergency switch-
ing off braking work in travel drive applications (values that differ from the tech-
nical data for BY brakes in this document).
3. Braking during inclined movement
As the inclined movement has a vertical and a horizontal component, the permitted
emergency switching off braking work is predominantly determined according to
point 1.
Contact SEW‑EURODRIVE if you are unable to classify the direction of motion as
solely vertical or solely horizontal.
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 271


10 BY brakes
BY brake project planning

10.6.7 Braking time / stopping distance

Braking time hoist downward


(JMot + Jext × ηG ) × nm,EmergencyStop
tB =
9.55 × (M1m,100°C − ML )

Braking time horizontal drive, hoist upward


(JMot + Jext × ηG ) × nm,EmergencyStop
tB =
9.55 × (M1m,100°C + ML )

Stopping distance
1
sb = v × 1000 × (t2 + tr + × tB )
2

10.6.8 Permitted gear unit load in case of emergency switching off


When using a gearmotor, in case of emergency switching off , the maximum dynamic
braking torque in case of emergency switching off M1max (see "Technical data of BK
brakes" (→ 2 241)) must not exceed the maximum permitted emergency switching off
torque MaEmergOff of the gear unit.
The value of the maximum permitted emergency switching off torque MaEmergOff is speci-
fied in the "Synchronous Servo Gearmotors" catalog.

MaEmergOff ≥ M2, 20°C × i × ηG

19381212/EN – 03/2015

272 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BY brakes
Technical data of BY brakes 10
10.7 Technical data of BY brakes
The following tables list the technical data of the brakes. The type and number of
brake springs determines the level of the braking torque. If not specified otherwise in
the order, brakemotors are delivered with the braking torques indicated with gray
background.

Motor type Brake type M2, 20 °C M4, 100 °C M1m, 100 °C P t1 t2 t3


Nm Nm Nm W ms ms ms
CMPZ71S BY2 7 4.2 4.9 27 25 23 130
10 6 7
14 8.4 9.8
10
20 12 14
CMPZ71M/L BY2 7 4.2 4.9 27 25 23 130
10 6 7
14 8.4 9.8
20 12 14
CMPZ80S BY4 14 8.4 9.8 38 30 17 110
20 12 14
28 16.8 19.6
40 24 28
CMPZ80M/L BY4 14 8.4 9.8 38 30 17 110
20 12 14
28 16.8 19.6
40 24 28
CMPZ100S BY8 28 16.8 19.6 45 55 25 210
40 24 28
55 33 38.5
80 48 56
CMPZ100M/L BY8 28 16.8 19.6 45 55 25 210
40 24 28
55 33 38.5
80 48 56
CMP112S BY14 50 30 35 76 60 20 100
70 42 49
100 60 70
19381212/EN – 03/2015

140 84 98
CMP112M/L BY14 50 30 35 76 60 20 100
70 42 49
100 60 70
140 84 98

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 273


10 BY brakes
Technical data of BY brakes

Motor type Brake type M2, 20 °C M4, 100 °C M1m, 100 °C P t1 t2 t3


Nm Nm Nm W ms ms ms
CMP112L/H/E BY14 50 30 35 76 60 20 100
70 42 49
100 60 70
140 84 98

Standard braking torque


Optional braking torque
M2, 20 °C Nominal torque for slipping brake disk (relative speed between brake disk
and friction surface: 1 m/s) at 20 °C
M4, 100 °C Minimum static braking torque (holding torque) at 100 °C
M1m, 100 °C Minimum averaged dynamic braking torque in case of emergency switch-
ing off at 100 °C
P Power consumption of the coil
t1 Brake response time
t2 Brake application time AC / DC
t3 Brake application time AC

INFORMATION
The response and application times are guide values that were determined at maxi-
mum braking torque.
Possible response times of switching elements or controllers were not taken into ac-
count.

The following table lists the permitted friction work from which the braking procedure is
triggered, depending on the start speed. The lower the speed, the higher the permitted
braking work.

INFORMATION
If you do not stop the motor in an inverter-controlled manner but use the brake for
mechanical deceleration, you must check whether the brake can supply the braking
work required for the brake application speed in an emergency switching off situation
(→ 2 271).

INFORMATION
If the braking work W1 (all applications) is exceeded, the increased braking work W1
(only travel drive applications) can be used in the case of a travel drive application.
Emergency switching off features (→ 2 271).
19381212/EN – 03/2015

274 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BY brakes
Technical data of BY brakes 10
Rated speed Brake type M2, 20 °C W1 W1 Winsp
for all applications only for travel drive
rpm Nm 103 kJ
applications
kJ
kJ
2000 BY2 7 20 40 35
10 18 36
14 15 30
20 12 24
BY4 14 24 48 50
20 19.5 39
10
28 17 34
40 10.5 21
BY8 28 48 96 60
40 44 88
55 32 64
80 18 36
BY14 50 39 77 200
70 37 73
100 28 56
140 18 37
3000 BY2 7 20 40 35
10 18 36
14 14 28
20 11 22
BY4 14 20 40 50
20 15 30
28 10 20
40 4.5 9
BY8 28 36 72 60
40 32 64
55 18 36
80 7 14
BY14 50 34 69 200
70 29 58
19381212/EN – 03/2015

100 16 32
140 10 19

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 275


10 BY brakes
Technical data of BY brakes

Rated speed Brake type M2, 20 °C W1 W1 Winsp


for all applications only for travel drive
rpm Nm 103 kJ
applications
kJ
kJ
4500 BY2 7 16 32 35
10 14 28
14 10 20
20 6 12
BY4 14 15 30 50
20 9 18
28 5 10
40 3 6
BY8 28 22 44 60
40 18 36
55 11 22
80 4 8
BY14 50 25 49 200
70 14 28
100 8.6 17
140 4.3 8.6
6000 BY2 7 14 28 35
10 13 26
14 8 16
20 4.5 9

M2, 20 °C Nominal torque for slipping brake disk (relative speed between brake disk
and friction surface: 1 m/s) at 20 °C
W1 Permitted braking work per cycle
Winsp Permitted total braking work (braking work until maintenance)
19381212/EN – 03/2015

276 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BY brakes
Technical data of BY brakes 10
10.7.1 Motor assignment
The BY brake can be used for the following rated speeds and braking torques depend-
ing on the motor size:

Motor type Brake M2, 20 °C Speed class


type Nm
CMPZ71S 7 10 14 20 2000 / 3000 /
BY2
CMP71ZM/L 7 10 14 20 4500 / 6000

CMPZ80S 14 20 28 40 2000 / 3000 /


BY4
CMP80ZM/L 14 20 28 40 4500

CMPZ100S 28 40 55 80 2000 / 3000 / 10


BY8
CMPZ100M/L 28 40 55 80 4500

CMP112S 50 70 100 140


2000 / 3000 /
CMP112M/L BY14 50 70 100 140
4500
CMP112L/H/E 50 70 100 140

M2, 20 °C Nominal torque for slipping brake disk (relative speed between brake disk
and friction surface: 1 m/s) at 20 °C
Standard braking torque
Optional braking torque

10.7.2 No-load starting frequency


The following no-load starting frequency Z0 must not be exceeded in order to prevent
the BY brake from heating up.

Brake type No-load starting frequency


BY2 7200 1/h
BY4 5400 1/h
BY8 3600 1/h
BY14 2400 1/h
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 277


10 BY brakes
Technical data of BY brakes

10.7.3 Determining the brake voltage


The brake voltage should always be selected on the basis of the available AC supply
voltage or motor operating voltage. This means the user is always guaranteed the
most cost-effective installation for lower braking currents.
The standard brake voltages are listed in the following table:

Brake type BY2, BY4, BY8, BY14


Nominal voltage DC 24 V1)
AC 110 V
AC 230 V
AC 400 V
AC 460 V
1) The 24 V brake voltage requires a strong current and is only possible with limited cable length.

When releasing the brake, the holding current can increase by up to 5.2 times. The
voltage at the brake coil must not drop below 90% of the nominal voltage.

19381212/EN – 03/2015

278 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BY brakes
Technical data of BY brakes 10
10.7.4 Operating currents of BY brakes
The following tables list the operating currents of the brakes at different voltages. The
following values are specified:
• Inrush current ratio IB/IH; IB = accelerator current, IH = holding current
• Holding current IH
• Nominal voltage UN
The acceleration current IB (= inrush current) only flows for a short time (about 150 ms)
when the brake is released or during voltage dips below 70% of nominal voltage.
The values for the holding currents IH are rms values (with DC 24 V arithmetic mean
value). Use suitable measuring instruments for current measurements.

BY2 BY4 BY8 BY14 10


Braking torque M2, 20 °C in 20 40 80 140
Nm
Braking power in W 27 38 45 76
Inrush current ratio IB/IH 5 4 4 5.2
or IB/IG

Nominal voltage UN IH IG IH IG IH IG IH IG
VAC VDC AAC ADC AAC ADC AAC ADC AAC ADC
24 – 1.05 – 1.4 – 1.6 – 2.8
(21.6 –
26.4)
110 0,425 – 0.58 – 0.69 – 1.542 –
(99 – 121)
230 0.19 – 0.26 – 0.305 – 0.689 –
(218 – 243)
400 0.107 – 0.147 – 0.172 – 0.387 –
(380 – 431)
460 0.095 – 0.131 – 0.154 – 0.345 –
(432 – 484)

M2, 20 °C Nominal torque for slipping brake disk (relative speed between brake disk
and friction surface: 1 m/s) at 20 °C
IH Holding current, r.m.s. value in the supply cable to the SEW brake rectifier
IG Direct current with direct DC voltage supply
VN Nominal voltage (nominal voltage range)
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 279


10 BY brakes
Technical data of BY brakes

10.7.5 Resistance values of BY brake coils

BY2 BY4 BY8 BY14


Braking torque M2, 20 °C in 20 40 80 140
Nm
Braking power in W 27 38 45 76

Nominal voltage UN RB RT RB RT RB RT RB RT
VAC VDC Ω Ω Ω Ω Ω Ω Ω Ω
24 5.2 20 4.3 13.3 3.8 11.2 1.6 6.5
(21.6 –
26.4)
110 16.3 64 13.7 42 12 35.5 4.9 20.5
(99 – 121)
230 82 320 69 210 60 177 24.6 102.8
(218 – 243)
400 260 1010 215 670 191 560 77.8 325.1
(380 – 431)
460 325 1270 275 840 240 700 97.9 409.3
(432 – 484)

M2, 20 °C Nominal torque for slipping brake disk (relative speed between brake disk
and friction surface: 1 m/s) at 20 °C
RB Accelerator coil resistance at 20 °C
RT Coil section resistance at 20 °C
UN Nominal voltage (nominal voltage range)

19381212/EN – 03/2015

280 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BY brakes
Technical data of BY brakes 10
10.7.6 Braking work and braking torques

Brake Braking Braking torque settings


type work until
Pressure Braking Type and number of Order numbers for
mainte-
plate or- torque brake springs
nance
der num-
Winsp M2, 20 °C
ber
106 J Nm Normal Red Blue Normal Red/blue
BY2 35 16450450 20 6 – – 01866621 01837427
14 4 2 –
16450965 10 3 – –
10
7 2 2 –
BY4 50 16445856 40 6 – – 0186663X 01840037
28 4 2 –
16447840 20 3 – –
14 2 2 –
BY8 60 16444876 80 6 – – 16446011 16446038
55 4 2 –
16447859 40 3 – –
28 2 2 –
BY14 200 16451422 140 4 – 4 13741837 13741845
100 3 – 3
16451961 70 2 – 2
50 - – 4

10.7.7 B10d values


Definition of the characteristic safety value B10d:
The value B10d specifies the number of cycles at which 10% of components have failed
dangerously (definition according to standard EN ISO 13849). Failed dangerously
means in this context that the brake is not applied when required. This means the
brake does not deliver the necessary braking torque.

Size B10d
BY.. Switching cycles
BY2 8 000 000
BY4 6 000 000
BY8 3 000 000
19381212/EN – 03/2015

BY14 2 000 000

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 281


10 BY brakes
Technical data of BY brakes

10.7.8 Manual brake release


In brakemotors with /HR option “Manual brake release with automatic reengaging
function,” you can release the brake manually using the provided lever. The following
table specifies the actuation force required at maximum braking torque to release the
brake manually. The values are based on the assumption that you operate the lever at
the upper end.

FH

4810849419

Brake type Motor type Actuation force FH


in N
BY2 CMPZ71 50
BY4 CMPZ80 70
BY8 CMPZ100 90
BY14 CMP112 300
For BY2, BY4, and BY8, the manual brake release option /HR can no longer be com-
bined with the forced cooling fan option /VR.

Manual brake release retrofit set


The manual brake release of the BY brake can be retrofitted. The following retrofit sets
can be used depending on the brake size:

Retrofit set Part number


BY2 17508428
19381212/EN – 03/2015

BY4 17508525
BY8 17508622
BY14 17573300

282 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BY brakes
Dimensioning and routing the cable for terminal boxes 10
10.8 Dimensioning and routing the cable for terminal boxes
10.8.1 Selecting the cable
Select the cross section of the brake cable according to the currents in your applica-
tion. Observe the inrush current of the brake when selecting the cross section. When
taking the voltage drop into account due to the inrush current, the value must not drop
below 90% of the nominal voltage. The data sheets for the brakes provide information
on the possible supply voltages and the resulting operating currents.
Information about the size of the cable cross-section and the cable lengths can be
found in the "Cable assignments" (→ 2 344) tables.
Wire cross sections of max. 2.5 mm2 can be connected to the terminals of the
brake control systems. Intermediate terminals must be used if the cross sec-
tions are larger. 10

10.8.2 Routing information


Brake cables must always be routed separately from other power cables with
phased currents unless they are shielded.
Ensure adequate equipotential bonding between the drive and the control cabi-
net (for an example, see the documentation Drive Engineering - Practical Imple-
mentation "EMC in Drive Engineering").
Power cables with phased currents include in particular:
• Output cables from frequency inverters and servo inverters, soft start units and
brake units
• Supply cables to braking resistors

10.9 Selecting the braking contactor


• Due to the high current loading and the DC voltage to be switched at inductive
load, contactors in utilization category AC 3 (EN 60947-4-1) must always be used
for controlling the brake rectifiers.
• For brake control via BSG and BMV, contactors in utilization category DC 3 must
be used (EN 60947‑4‑1).

10.9.1 Standard design


If not specified otherwise in the order, CMP brakemotors are delivered with BY brake
with BME for AC connection.

Switching via contactor

Brake type AC connection DC 24 V connection


BY2, BY4, BY8, BY14 BME BSG
19381212/EN – 03/2015

Control via inverter

Brake type AC connection DC 24 V connection


BY2, BY4, BY8, BY14 BMK BMV

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 283


10 BY brakes
Selecting the brake control system

10.10 Selecting the brake control system


Only SEW brake control systems are used for controlling the brake. All brake control
systems are fitted with varistors as standard to protect against overvoltage.
The brakes are available with DC and AC voltage connection.
• AC voltage connection:
– BME, equipped with DIN rail profile
• DC voltage connection:
– BSG
There are two possible ways of electrical disconnection:
• Normal application times: cut-off in the AC circuit.
• Particularly short application times: cut-off in the AC and DC circuits.
The brake control systems are mounted in the control cabinet. Retaining screws are
included in the delivery.
The following options are available:
• AC supply, cut-off in the AC and DC circuits without additional switch contact, par-
ticularly short application times: BMP.
• AC supply, brake heating function when switched off: BMH.
• The BMK/BMKB/BMV control system energizes the brake coil if the supply system
and a DC 24 V signal (e.g. from the PLC) are present simultaneously. The brake is
applied if one condition is not being met. BMK/BMKB/BMV allow for shortest re-
sponse and application times.

INFORMATION
A disconnection of all poles is mandatory for emergency stop and for hoists in gen-
eral (terminals 1 and 2 of the brake rectifier).

The following table lists SEW brake control systems for installation in the control cabi-
net. The different housings have different colors (= color code) to make them easier to
distinguish.

Brake con- Function Voltage Holding Type Part num- Color


trol current ber code
IHmax
A
BME One-way rectifier with elec- AC 150 to 1.5 BME 1.5 8257221 Red
tronic switching 500 V
AC 42 to 150 V 3.0 BME 3 825723X Blue
BMH One-way rectifier with elec- AC 150 to 1.5 BMH 1.5 825818X Green
tronic switching and heating 500 V
function
AC 42 to 150 V 3 BMH 3 8258198 Yellow
19381212/EN – 03/2015

BMP One-way rectifier with elec- AC 150 to 1.5 BMP 1.5 8256853 White
tronic switching, integrated 500 V
voltage relay for switch-off in
AC 42 to 150 V 3.0 BMP 3 8265666 Light
the DC circuit
blue

284 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BY brakes
Selecting the brake control system 10
Brake con- Function Voltage Holding Type Part num- Color
trol current ber code
IHmax
A
BMK One-way rectifier with elec- AC 150 to 1.5 BMK 1.5 8264635 Water
tronic switching, DC 24 V con- 500 V blue
trol input and cut-off in the DC
AC 42 to 150 V 3.0 BMK 3 8265674 Light red
circuit
BMKB One-way rectifier with elec- AC 150 to 1.5 BMKB 8281602 Water
tronic switching, DC 24 V con- 500 V 1.5 blue
trol input, cut-off in the DC cir-
cuit, and a diode to signal
10
readiness for operation
BSG Control unit for DC 24 V con- DC 24 V 5.0 BSG 8254591 White
nection with electronic switch-
ing
BMV Electric switching, DC 24 V DC 24 V 5.0 BMV 13000063 White
control input and cut-off in the
DC circuit

10.10.1 Quick response times


A characteristic feature of the SEW brake is the patented two-coil system. This system
consists of accelerator coil and coil section. The special SEW brake control system
ensures that the accelerator coil is switched on with a high current inrush when the
brake is released, after which the coil section is switched on. The result is a particular-
ly short response time when releasing the brake. The brake disk moves clear very
swiftly and the motor starts up with hardly any brake friction.
This principle of the two coil system also reduces self-induction so that the brake is
applied more rapidly. The result is a reduced braking distance. The SEW brake can be
cut off in the DC and AC circuits to achieve particularly short response times when ap-
plying the brake, for example for hoists.
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 285


10 BY brakes
Block diagram of brake control – plug connectors

10.11 Block diagram of brake control – plug connectors


In the following block diagrams, the contactor for the supply voltage of the brake recti-
fier is designated as K12. Except for BMV, BMKB and BMK, it is used to also switch
the brake.
BMV and BMK: In applications without requirements on functional safety, it is sufficient
to switch the brake via connections 3 and 4 (depicted as N.O. contact without name).
In applications with requirements on functional safety (such as hoists), all poles must
be switched off to ensure that the brake is applied even in the event of a fault in the
brake rectifier.

10.11.1 BME brake rectifier


Cut-off in the AC circuit / standard application of the brake with SB1, SBB.

BME BME

13
14
15
13
14
15

1
2
3
4
1
2
3
4

SB1 SBB

D 3
V
K12 C K12
- +
4 W U

U AC B
U AC 1
2
A 1

2901967755

Cut-off in the AC circuit / standard application of the brake with SBC.


BME
13
14
15
1
2
3
4

SBC

V
K12
- +
W U

U AC 2

9007206235835659
19381212/EN – 03/2015

286 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Block diagram of brake control – plug connectors
BY brakes
10
Cut-off in the DC and AC circuits / rapid application of the brake with SB1, SBB.

BME BME

13
14

13
14
15

15
1
2
3
4

1
2
3
4
SB1 SBB

D 3
V
K12 C K12
- +
4 W U

U AC B
U AC 1
2
A 1
10
2901969419

Cut-off in the DC and AC circuits / rapid application of the brake with SBC.
BME
13
14
15
1
2
3
4

SBC

V
K12
- +
W U

U AC 2
1

9007206235910283

10.11.2 BMP brake rectifier


Cut-off in the DC and AC circuits / rapid application of the brake / integrated voltage
relay with SBB.

BMP BMP
13
14
13
14

15
15

1
2
3
4
1
2
3
4

SB1 SBB

D 3
V
K12 C K12
- +
4 W U

U AC B
U AC 1
19381212/EN – 03/2015

2
A 1

2901972107

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 287


10 BY brakes
Block diagram of brake control – plug connectors

Cut-off in the DC and AC circuits / rapid application of the brake / integrated voltage
relay with SBC.
BMP

13
14
15
1
2
3
4
SBC

V
K12
- +
W U

U AC 2
1

9007206235946507

10.11.3 BMH brake rectifier


Cut-off in the AC circuit / standard application of the brake with SBB.

BMH BMH

13
14
13
14

15
15

1
2
3
4
1
2
3
4

SB1 SBB
K12 K12
D 3
V
C
- +
4 W U

U AC B
U AC 1
2
A 1

2901974795

Cut-off in the AC circuit / standard application of the brake with SBC.


BMH
13
14
15
1
2
3
4

SBC
K12

V
- +
W U

U AC 2
1
19381212/EN – 03/2015

9007206235982731

288 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Block diagram of brake control – plug connectors
BY brakes
10
Cut-off in the DC and AC circuits / rapid application of the brake with SBB.

BMH BMH

13
14
13
14

15
15

1
2
3
4
1
2
3
4

K12 SB1 K12 SBB

D 3
V
C
- +
4 W U

U AC U AC 1
B
2
A 1
10
2901976459

Cut-off in the DC and AC circuits / rapid application of the brake with SBC.
BMH
13
14
15
1
2
3
4

K12 SBC

V
- +
W U

U AC 2
1

9007206236018571

10.11.4 BMK brake controller


Cut-off in the DC and AC circuits / rapid application of the brake / integrated voltage
relay / DC 24 V control input integrated with SBB.
BMK BMK
13
14
13
14

15
15

1
2
3
4
1
2
3
4

SB1 SBB

D 3
V
K12 C K12
- +
4 W U

U AC + - U AC + - 1
B
24 VDC 24 VDC 2
19381212/EN – 03/2015

A 1

2901979147

Connection 1, 2 Power supply


Connection 3, 4 Signal (inverter)

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 289


10 BY brakes
Block diagram of brake control – plug connectors

Cut-off in the DC and AC circuits / rapid application of the brake / integrated voltage
relay / DC 24 V control input integrated with SBC.
BMK

13
14
15
1
2
3
4
SBC

V
K12
- +
W U

U AC + - 2

24 VDC 1

9007206236054795

Connection 1, 2 Power supply


Connection 3, 4 Signal (inverter)

10.11.5 BMKB brake controller


Cut-off in the DC and AC circuits / rapid application of the brake / integrated voltage
relay / DC 24 V control input integrated / indication of readiness for operation with di-
ode with SBB.
BMKB BMKB
13
14
13
14

15
15

1
2
3
4
1
2
3
4

SB1 SBB

D 3
V
K12 C K12
- +
4 W U

U AC + - U AC + - 1
B
24 VDC 24 VDC 2
A 1

2901981835

Connection 1, 2 Power supply


Connection 3, 4 Signal (inverter)
19381212/EN – 03/2015

290 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Block diagram of brake control – plug connectors
BY brakes
10
Cut-off in the DC and AC circuits / rapid application of the brake / integrated voltage
relay / DC 24 V control input integrated / indication of readiness for operation with di-
ode with SBC.
BMKB

13
14
15
1
2
3
4
SBC

V
K12
- +
W U

U AC + - 2
10
24 VDC 1

9007206236091019

Connection 1, 2 Power supply


Connection 3, 4 Signal (inverter)

10.11.6 BMV brake controller


Cut-off in the DC and AC circuits / rapid application of the brake / DC 24 V control in-
put integrated with SBB.
BMV BMV
13
14
13
14

15
15

1
2
3
4
1
2
3
4

SB1 SBB

D 3
V
K12 C K12
- +
4 W U

24 VDC + - B
24 VDC + - 1
24 VDC 24 VDC 2
A 1

2901984523

Connection 1, 2 Power supply


Connection 3, 4 Signal (inverter)
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 291


10 BY brakes
Block diagram of brake control – plug connectors

Cut-off in the DC and AC circuits / rapid application of the brake / DC 24 V control in-
put integrated with SBC.
BMV

13
14
15
1
2
3
4
SBC

V
K12
- +
W U

24 VDC + - 2

24 VDC 1

9007206236127243

Connection 1, 2 Power supply


Connection 3, 4 Signal (inverter)

10.11.7 BSG brake control unit


For DC 24 V supply with SBB.
BSG BSG

1 2 3 4 5 SB1 1 2 3 4 5

D 3
SBB
C

4 V
- +
B
W U
A 1
- + - +
1
24 VDC 24 VDC
2

2901987211

For DC 24 V supply with SBC.


BSG

1 2 3 4 5

SBC

V
- +
19381212/EN – 03/2015

W U
- +
2
24 VDC
1

9007206236163467

292 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BY brakes
Block diagram of brake control – terminal box 10
10.12 Block diagram of brake control – terminal box
In the following block diagrams, the contactor for the supply voltage of the brake recti-
fier is designated as K12. Except for BMV, BMKB and BMK, it is used to also switch
the brake.
BMV and BMK: In applications without requirements on functional safety it is sufficient
to switch the brake via connections 3 and 4 (depicted as N.O. contact without name).
In applications with requirements on functional safety (such as hoists), all poles must
be switched off to ensure that the brake is applied even in the event of a fault in the
brake rectifier.

10.12.1 BME brake rectifier


Cut-off in the AC circuit / standard application of the brake. 10
BME

13
14
15
1
2
3
4

3a

K12 4a
5a

1
U AC 2
3
4
5
6
7
8
9
10

2901761291

Cut-off in the DC and AC circuits / rapid application of the brake.


BME
13
14
15
1
2
3
4

3a
4a
5a
K12
1
2
3
U AC
4
5
6
7
8
9
19381212/EN – 03/2015

10

2901762955

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 293


10 BY brakes
Block diagram of brake control – terminal box

10.12.2 BMP brake rectifier


Cut-off in the DC and AC circuits / rapid application of the brake / integrated voltage
relay.
BMP

13
14
15
1
2
3
4
3a
4a
5a
K12
1
2
3
U AC
4
5
6
7
8
9
10

2901765643

10.12.3 BMH brake rectifier


Cut-off in the AC circuit / standard application of the brake.
BMH
13
14
15
1
2
3
4

K12 3a
4a
5a

1
2
U AC 3
4
5
6
7
8
9
10

2901768331
19381212/EN – 03/2015

294 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BY brakes
Block diagram of brake control – terminal box 10
Cut-off in the DC and AC circuits / rapid application of the brake.
BMH

13
14
15
1
2
3
4
K12 3a
4a
5a

1
2
U AC 3
4
5
6 10
7
8
9
10

2901999627

10.12.4 BMK brake rectifier


Cut-off in the DC and AC circuits / rapid application of the brake / integrated voltage
relay.
BMK
13
14
15
1
2
3
4

3a
4a
5a
K12
1
2
U AC 3
+ -
4
24 VDC 5
6
7
8
9
10

2901772683

Connection 1, 2 Power supply


Connection 3, 4 Signal (inverter)
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 295


10 BY brakes
Block diagram of brake control – terminal box

10.12.5 BSG brake control unit


For DC voltage supply with DC 24 V.
BSG

1 2 3 4 5
3a
4a
5a

1
2
3
- + 4
24 VDC 5
6
7
8
9
10

2901775371

19381212/EN – 03/2015

296 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BY brakes
Dimension drawings for BY brake control 10
10.13 Dimension drawings for BY brake control
10.13.1 Dimension drawing for BME, BMP, BMH, BMK, BMKB, BMV

75
23 5 68 10
90

[1]

4810854155

[1] Support rail mounting according to EN 50022‑35‑7.5 (not included in the delivery)

10.13.2 Dimensions BSG


32.5
14
12

36
4.4

1 2 3 4 5

60.5
70
78

4810856843
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 297


10 BY brakes
Safety-rated BY..(FS) brakes

10.14 Safety-rated BY..(FS) brakes


You find more detailed information on functional safety in the "Safe Brake System –
Synchronous Servomotors" manual.

10.14.1 Safety functions


By adding a safety-rated brake to a brake system, the following safety functions can
be implemented:
• SBA (safe brake actuation)
• SBH (safe brake hold)

INFORMATION
• SBA and SBH additionally require the SBC safety function for safety-related shut-
down of the power supply of the brake.
• Depending on the configuration and use in the application, a drive can generate
more torque than the brake is able to hold/stop. When activating the SBA/SBH
safety function, the drive must be switched off with the STO safety function.
• SBA and SBH are defined by SEW-EURDORIVE based on the standard
DIN EN 61800‑5‑2.

10.14.2 Performance levels that can be achieved


Brakes are a component of a safe brake system. The performance level of the safe
brake system that can be achieved is influenced by the following factors:
• The safety architecture, category (cat.) selected in accordance with EN ISO 13849
• How often the system is used in the application (B10d, MTTFd)
• An available brake diagnosis (DC)
• The application in which the system is used (horizontal or vertical application)

19381212/EN – 03/2015

298 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BY brakes
Safety-rated BY..(FS) brakes 10
10.14.3 Differences between BY and BY(FS) brakes
The most important differences between the technical properties of the standard BY..
brake and the safety-rated BY..(FS) brake are listed below.

BY.. standard brake FS brake BY (FS)


Brake type All All
Field of application
Holding brake Yes Yes (with emergency switching off prop-
erties)
Working brake Yes No
Ambient temperature
10
-20 °C to +40 °C Yes Yes
Other ambient temperatures Yes No
Braking torques All Restrictions depending on the mounting
position
Brake options
Manual brake release All HF not permitted
HR cannot be retrofitted
Maintenance of the drive
Customer Yes No
SEW‑EURODRIVE Yes Yes
Motor type
CMP. motors CMPZ71 – CMPZ100, CMP112 CMPZ71 – CMPZ100
Motor options
KY Yes Must be used
TF Yes (special design) No
Z Yes Yes
Speed class
6000 rpm Yes No
Encoder
All except for AK0H encoders Approved:
• RH1M
• EK1H
• AK1H
• AK1H(FS)
19381212/EN – 03/2015

Gear unit combination with All Restriction of the permitted braking tor-
ques
pinion bore / pinion shaft
end
Gear units
RM..., R.07, R.17 Yes No
WT.., W..10, W..20, W..30 Yes No

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 299


10 BY brakes
Safety-rated BY..(FS) brakes

BY.. standard brake FS brake BY (FS)


PS.C Yes No
Hollow shaft with shrink disk Yes Restriction of the permitted braking tor-
ques
TorqLOC® Yes No
Gear unit adapter Yes No
Double gear unit Yes No
Special designs Yes No (on request from SEW‑EURODRIVE)
Mounting position All Restriction of the permitted braking tor-
ques
SEW measures Standard • Additional assembly steps
• Additional documentation
• Traceability up to batch monitoring
• Manipulation protection at critical
points
Category B 1
B10d value Standard Higher values than the standard
Specification per size Specification per size
All the other components, such as the gear unit type, suitable ratio i, service factor fB,
load change, output shaft, etc. must be selected and evaluated by the customer.

19381212/EN – 03/2015

300 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BY brakes
Safety-rated BY..(FS) brakes 10
10.14.4 Safety-rated brake control
If the BY..(FS) brake is used in safety-related applications, then brake control must be
taken into consideration in the safety evaluation.
Various brake controllers are available for controlling disk brakes with a DC coil, de-
pending on the requirements and the operating conditions. All brake control systems
are fitted with varistors as standard to protect against overvoltage.

INFORMATION
Under certain conditions, non-safety-rated brake controls can also be used in safe
brake systems.
Contact SEW‑EURODRIVE for more information.
10
Safety-related BST brake module
The safety-related BST brake module safely disconnects the energy supply to the
brake.
The BST brake module offers one these safety functions:
• SBC (safe brake control), up to PL d according to EN ISO 13849
The BST brake module offers many advantages compared to conventional technolo-
gy:
• Less space required in the control cabinet (no contactor and no motor protection
switch)
• Improved energy balance (energy efficient as the regenerative energy from the
DC link can be used)
• Reduced wiring work
• Easy installation
• Easy safety assessment
• No wear
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 301


10 BY brakes
Safety-rated BY..(FS) brakes

Approved unit combinations


The following BST types are permitted for safety-related applications:

Type designation Part number Approved disk brakes from SEW‑EURODRIVE


BST 0.6S-460V-00 08299714 All brake coils with a coil voltage of AC 460 V and a coil power of
≤ 120 W.
Several brake coils can be connected for redundant systems. In this
case, the total power must not exceed 120 W.
BST 0.7S-400V-00 13000772 All brake coils with a coil voltage of AC 400 V and a coil power of
≤ 120 W.
Several brake coils can be connected for redundant systems. In this
case, the total power must not exceed 120 W.
BST 1.2S-230V-00 13001337 All brake coils with a coil voltage of AC 230 V and a coil power of
≤ 120 W.
Several brake coils can be connected for redundant systems. In this
case, the total power must not exceed 120 W.

Brake type Synchronous motor


CMP.71 CMP.80 CMP.100 CMP112
BY2 x
BY4 x
BY8 x
BY14 x

The following unit combinations (inverter/BST) are approved.

Inverter type Unit design Comments


MOVIDRIVE® B 3 × AC 380 – 500 V Connection of BST to size 7
with DC link adapter.
Sizes 0 – 7
®
MOVIAXIS Connection to all supply and re- Installation via connection set
generative modules as well as BST to MXP, MXR, MXC, and
capacitance and buffer modules. MXNB.
19381212/EN – 03/2015

302 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


BY brakes
Safety-rated BY..(FS) brakes 10
10.14.5 Dimension drawing of BST in control cabinet design
The following figure shows the dimension drawings of BST in control cabinet design.
Dimensions in mm
135 (5.31)

121.5 (4.78)

70 (2.76)

10
89 (3.50)

99 (3.90)
101 (3.98)
135 (5.31)

74 (2.91)
19381212/EN – 03/2015

9007199388556683

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 303


10 BY brakes
Safety-rated BY..(FS) brakes

10.14.6 Safety characteristics of BST brake modules

Characteristic values according to


EN ISO 13849-1
Classification PL d
System structure Category 3
Probability of dangerous failure 0 (fault exclusion)
per hour (PFH value)
Mission time / service life 20 years
Safe condition Brake de-energized
Safety function SBC (safe brake control) according to
IEC 61800-5-2

10.14.7 Braking work and braking torques


For the V3 mounting position (brake on the bottom with manual brake release), the
braking torques marked in gray in the following table are not available:

Brake type Braking work un- Braking torque settings


til maintenance
Braking torque Type and number of brake
springs
M2, 20 °C

6
10 J Nm Normal Red
20 6 -
14 4 2
BY2 35
10 3 -
7 2 2
40 6 -
28 4 2
BY4 50
20 3 -
14 2 2

10.14.8 B10d values BY..(FS)


Definition of the characteristic safety value B10d:
The value B10d specifies the number of cycles at which 10% of components have failed
dangerously (definition according to standard EN ISO 13849). Failed dangerously
means in this context that the brake is not applied when required. This means the
brake does not deliver the necessary braking torque.

Size B10d
19381212/EN – 03/2015

BY..(FS) Switching cycles


BY2 15 000 000
BY4 12 000 000
BY8 9 000 000

304 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Motor types
Standard type – encoders 11
11 Motor types
11.1 Standard type – encoders
11.1.1 Resolver

Type designation
/RH1M

Description
CMP servomotors are delivered with 2-pole resolvers as standard. Further information
on other resolvers is available on request.

11.1.2 Option: Hiperface® encoders 11


CMP servomotors are optionally available with the following Hiperface® multi-/single-
turn encoders:

Designation Specification periods / Motor type Brake types


revolution
EK0H 128 CMP40 BK
1)
AK0H 128 CMP40 – 63, BP/BK
CMP.71 – 100,
CMP112
ES1H, AS1H 1024 CMP50 – 63 –
1)
EK1H, AK1H 1024 CMP50 – 63/BK, BP/BK/BY
CMP.71 – 100,
CMP112
1) Also available as safety-rated version

Type designation
/AK0H, /EK0H, /AK1H, /EK1H

Description
SEW‑EURODRIVE offers Hiperface® encoders also as multi-turn absolute encoders
as an alternative to the resolver. Encoders with a high resolution are also available in
addition to the standard.

INFORMATION
The encoder signal can be influenced when applying the brake from speed. It is
therefore important that the inverter defines its encoder position again after this proc-
ess. This is not necessary in regular operation when the brake is actuated at stand-
still.
19381212/EN – 03/2015

When prefabricating the encoder cables, ensure correct polarity for the supply outputs.

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 305


11 Motor types
Standard type – encoders

11.1.3 Encoders – technical data

Resolver

/RH1M

Type RH1M
CMP40 – 63, CMP.71 – 100, CMP112
Number of poles 2
Primary Rotor
Input voltage 7V
Input frequency 7 kHz
Reduction ratio ± 10% 0.5
Phase shift ± 5° +13 °
Input impedance ± 15% 130 + j120 Ω
Output impedance ± 15% 200 + j270 Ω
Input resistance ± 10% 82 Ω
Output resistance ± 10% 68 Ω
Maximum electrical fault ± 6’
Temperature range -55 °C to +150 °C

19381212/EN – 03/2015

306 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Motor types
Standard type – encoders 11
Option: Hiperface® encoder

/EK0H, /AK0H

Type EK0H AK0H1)


Attachable to encoder CMP40 CMP40 – 63,
CMP.71 – 100, CMP112
Supply voltage DC 7 to 12 V polarity reversal protected
Maximum current consumption (with- 120 mA
out load)
Maximum operating frequency 26 kHz
Pulses (sine cycles) per revolution 128
Output amplitude per track 0.8 to 1.1Vpp sin/cos 11
Single-turn resolution 4096 increments/revolution (15 bits)
Multi-turn resolution – 4096 revolutions
(12 bits)
Transmission protocol Hiperface®
Serial data output Driver to EIA RS-485
Vibration resistance (10 to 2000 Hz) ≤ 100 m/s2 (DIN IEC 68‑2‑6)
Maximum speed 12000 rpm 9000 rpm
Temperature range -20 °C to +110 °C
1) Not available in combination with BY brake
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 307


11 Motor types
Standard type – encoders

Option: Hiperface® encoders

/ES1H, /AS1H

Type ES1H AS1H


Attachable to encoder CMP50, CMP63
Supply voltage DC 7 – 8 – 12 V polarity reversal protected
Max. current consumption 140 mA
Maximum operating frequency 200 kHz
Pulses (sine cycles) per revolution 1024
Output amplitude per track 0.9 to 1.1 Vpp sin/cos
Single-turn resolution 32768 increments/revolution (15 bits)
Multi-turn resolution – 4096 revolutions
(12 bits)
Transmission protocol Hiperface®
Serial data output Driver to EIA RS-485
Vibration resistance (10 to 2000 Hz) ≤ 200 m/s2 (DIN IEC 68‑2‑6)
Maximum speed 12000 rpm
Temperature range -20 °C to +110 °C

/EK1H, /AK1H

Type EK1H AK1H


Attachable to encoder CMP50 – 63/BK, CMP.71 – 100, CMP112
Supply voltage DC 7 – 8 – 12 V polarity reversal protected
Max. current consumption 140 mA
Maximum operating frequency 200 kHz
Pulses (sine cycles) per revolution 1024
Output amplitude per track 0.9 to 1.1 Vpp sin/cos
Single-turn resolution 32768 increments/revolution (15 bits)
Multi-turn resolution – 4096 revolutions
(12 bits)
Transmission protocol Hiperface®
Serial data output Driver to EIA RS-485
Vibration resistance (10 to 2000 Hz) ≤ 200 m/s2 (DIN IEC 68‑2‑6)
Maximum speed 12000 rpm
19381212/EN – 03/2015

Temperature range -30 °C to +110 °C

308 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Motor types
Standard type – encoders 11
11.1.4 Safety-rated encoders

General information
Hiperface® encoders AK0H and AK1H are optionally available for functional safety.
Using safety-rated encoders lets you implement safety functions SS1, SS2, SOS,
SLA, SLS, SDI, and SLI according to IEC 61800‑5‑2.
Certain demands on the mechanical coupling of the encoder system to the motor must
be met so that the encoder can be used for safety-relevant tasks.
SEW‑EURODRIVE assumes responsibility for the delivered motor with safety-rated
encoder in terms of compliance with the functional safety regulations. Safety-relevant
connection elements are sealed to be able to ensure that the delivery condition is not
changed, see following figures.

CMP40 CMP50 – 63
11
AK0H

[1]

[1]

9007203017040651 9007203017042315

CMP71 – 100 CMPZ71 – 100, CMP71 – 100 /BP,


CMP112

[1]

[1]

9007203017043979 9007203017045643
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 309


11 Motor types
Standard type – encoders

CMP71 – 100 CMPZ71 – 100, CMP71 – 100 /BP,


CMP112
AK1H

[1]
[1]
9007203034362379
3779561099

CMPZ71 – 100 /BY,


CMP112 /BY
[1] Sealed screw connections on the en-
coder

[1]
8468802571

19381212/EN – 03/2015

310 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Motor types
Standard type – encoders 11
Characteristic safety values

Characteristic safety values for AK0H encoders


The following table shows the characteristic safety values of the safety-rated AK0H
encoders:

Characteristic values according to


EN 62061 / IEC 61508 EN ISO 13849‑1
Classification/underlying stand- SIL2 according to EN 62061 PL d according to EN ISO 13849-1
ards
Structure HFT = 1 2 channels (corresponds to category
3 according to EN ISO 13849-1)
Probability of a dangerous fail- 1.3 × 10-8 1/h
ure per hour (PFHd value)1) 11
Mean time to dangerous failure – 100 years
(MTTFd value)2)
Mission time / service life 20 years
Proof test interval Not required –
Safe fault coverage (SSF) 95% –
Motor/encoder connection In the drive with FS identification, exclusion of errors according to EN ISO
13849
1) The specified value refers to the diagnostics coverage of 90% that must be achieved by an encoder evaluation unit. Diagnostics
must be performed within the process response time.
2) Ambient temperature 40 °C
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 311


11 Motor types
Standard type – encoders

Characteristic safety values for AK1H encoders


The following table shows the characteristic safety values of the safety-rated AK1H
encoder:

Characteristic values according to


EN 62061 / IEC 61508 EN ISO 13849‑1
Classification/underlying stand- SIL2 according to EN 62061 PL d according to EN ISO 13849-1
ards
Structure HFT = 1 2 channels (corresponds to category
3 according to EN ISO 13849-1)
Probability of a dangerous fail- 1.0 × 10-8 1/h
ure per hour (PFHd value)1)
Mean time to dangerous failure – 1073 years
(MTTFd value)2)
Mission time / service life 20 years
Proof test interval Not required –
Safe fault coverage (SSF) 95% –
Motor/encoder connection In the drive with FS identification, exclusion of errors according to EN ISO
13849
1) The specified value refers to the diagnostics coverage of 90% that must be achieved by an encoder evaluation unit. Diagnostics
must be performed within the process response time.
2) Ambient temperature 40 °C

19381212/EN – 03/2015

312 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Motor types
Standard type – motor protection 11
11.2 Standard type – motor protection
11.2.1 Thermal motor information with KTY

Type designation
/KY

Description
This type detects the motor temperature continuously using a semi-conductor sensor
for further processing in the inverter or controller.
The inverter + /KY option can only take on the function of motor protection when it is
used in combination with an inverter containing the thermal motor model.

11
11.2.2 Thermal motor information with KTY – technical data

/KY
KTY84 to 130 temperature sensors continuously detect the motor temperature.

Technical data KTY84 to 130


Connection Red (+)
Blue (–)
Total resistance at 20 to 25 °C 540 Ω < R < 640 Ω
Test current < 3 mA
Typical characteristic curve of KTY:
3000

2500

2000

R Ω 1500

1000

500

0
-100 -50 0 50 100 150 200 250 300 350
T °C
4816000395
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 313


11 Motor types
Standard type – motor protection

11.2.3 TF temperature sensor

Type designation
/TF

Description
Thermal motor protection prevents the motor from overheating and causing irrepara-
ble damage. The TF is a triple PTC thermistor. One TF is installed in every motor
phase and then connected in series.
A PTC thermistor is a resistance whose resistance value rises significantly from a
nominal response value as the temperature rises. Please refer to the following charac-
teristic curve.
The temperature sensor /TF can be designed as follows:
• in thermal class 155 (F)
• in thermal class 180 (H)
• in a double version
– for warning in 130 (B) and for disconnection in 155 (H),
– for warning in 155 (F) and for disconnection in 180 (H).
Please contact us if you are considering the double /TF design.

Notes on the selection


The positive temperature coefficient (PTC) temperature sensors comply with
DIN 44082.
Resistance measurement (measuring instrument with V ≤ 2.5 V or < 1 mA):
• Standard measured values: 20 – 500 Ω
• Hot resistance: > 4000 Ω
When using the temperature sensor for thermal monitoring, the evaluation function
must be activated to maintain reliable isolation of the temperature sensor circuit. If the
temperature reaches an excessive level, the thermal protection function must be
brought into effect immediately.

INFORMATION
The temperature sensor /TF may not be subjected to voltages > 30 V.
19381212/EN – 03/2015

314 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Motor types
Standard type – motor protection 11
The below figure shows the characteristic curve of a TF with reference to the nominal
response temperature (referred to as TNF).
R [Ω]

4000

1330

550

250

11

[T]

-20°C
TNF - 20 K

TNF - 5 K
TNF + 5 K
TNF + 15 K
TNF
4151365003
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 315


11 Motor types
Standard type – connection options

11.3 Standard type – connection options


11.3.1 Assignment table for connectors and terminal boxes to CMP servomotors
Key:

Version possible
Version not possible

System voltage 400 V, without forced cooling fan


Motor type Rated speed Power connection without/with brake
SM1/SB1 SMB/SBB SMC/SBC KK KKS
IEC UL CSA IEC UL CSA IEC UL CSA IEC UL CSA IEC UL CSA
CMP40S 3000
4500
6000
CMP40M 3000
4500
6000
CMP50S 3000
4500
6000
CMP50M 3000
4500
6000
CMP50L 3000
4500
6000
CMP63S 3000
4500
6000
CMP63M 3000
4500
6000
CMP63L 3000
4500
6000
CMP.71S 2000
3000
4500
6000
CMP.71M 2000
3000
4500
6000
CMP.71L 2000
3000
19381212/EN – 03/2015

4500
6000
CMP.80S 2000
3000
4500
6000

316 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Motor types
Standard type – connection options 11
Motor type Rated speed Power connection without/with brake
SM1/SB1 SMB/SBB SMC/SBC KK KKS
IEC UL CSA IEC UL CSA IEC UL CSA IEC UL CSA IEC UL CSA
CMP.80M 2000
3000
4500
6000
CMP.80L 2000
3000
4500
6000
CMP.100S 2000
3000
4500
CMP.100M 2000 11
3000
4500
CMP.100L 2000
3000
4500
CMP112S 2000
3000
4500
CMP112M 2000
3000
4500
CMP112L 2000
3000
4500
CMP112H 2000
3000
4500
CMP112E 2000
3000
4500
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 317


11 Motor types
Standard type – connection options

System voltage 400 V, with forced cooling fan


Motor type Rated speed Power connection without/with brake
SM1/SB1 SMB/SBB SMC/SBC KK KKS
IEC UL CSA IEC UL CSA IEC UL CSA IEC UL CSA IEC UL CSA
CMP50S/ VR 3000
4500
6000
CMP50M/ VR 3000
4500
6000
CMP50L/ VR 3000
4500
6000
CMP63S/ VR 3000
4500
6000
CMP63M/ VR 3000
4500
6000
CMP63L/ VR 3000
4500
6000
CMP.71S/ VR 2000
3000
4500
6000
CMP.71M/ VR 2000
3000
4500
6000
CMP.71L/ VR 2000
3000
4500
6000
CMP.80S/ VR 2000
3000
4500
6000
CMP.80M/ VR 2000
3000
4500
6000
CMP.80L/ VR 2000
3000
4500
CMP.100S/ VR 2000
3000
19381212/EN – 03/2015

4500
CMP.100M/ VR 2000
3000
4500
CMP.100L/ VR 2000
3000
4500

318 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Motor types
Standard type – connection options 11
Motor type Rated speed Power connection without/with brake
SM1/SB1 SMB/SBB SMC/SBC KK KKS
IEC UL CSA IEC UL CSA IEC UL CSA IEC UL CSA IEC UL CSA
CMP112S/ VR 2000
3000
4500
CMP112M/ VR 2000
3000
4500
CMP112L/ VR 2000
3000
4500
CMP112H/ VR 2000
3000
4500 11
CMP112E/ VR 2000
3000
4500
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 319


11 Motor types
Standard type – connection options

System voltage 230 V, without forced cooling fan


Motor type Rated Power connection without/with brake
speed SM1/SB1 SMB/SBB SMC/SBC KK KKS
IEC UL CSA IEC UL CSA IEC UL CSA IEC UL CSA IEC UL CSA
CMP40S 3000
4500
6000
CMP40M 3000
4500
6000
CMP50S 3000
4500
6000
CMP50M 3000
4500
6000
CMP50L 3000
4500
6000
CMP63S 3000
4500
6000
CMP63M 3000
4500
6000
CMP63L 3000
4500
6000
CMP.71S 3000
4500
6000
CMP.71M 3000
4500
CMP.71L 3000
CMP.80S 3000
4500
6000
CMP.80M 3000
4500
CMP.80L 3000
CMP.100S 3000
4500
CMP.100M 3000
19381212/EN – 03/2015

320 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Motor types
Standard type – connection options 11
System voltage 230 V, with forced cooling fan
Motor type Rated Power connection without/with brake
speed SM1/SB1 SMB/SBB SMC/SBC KK KKS
IEC UL CSA IEC UL CSA IEC UL CSA IEC UL CSA IEC UL CSA
CMP.71S/ VR 3000
4500
6000
CMP.71M/ VR 3000
4500
CMP.71L/ VR 3000
CMP.80S/ VR 3000
4500
6000
CMP.80M/ VR 3000
4500 11
CMP.80L/ VR 3000
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 321


11 Motor types
Standard type – connection options

11.3.2 Plug connector connection option

CMP40 – CMP63: SM1/SB1 plug connector


Adjustable Radial

CMP.71 – CMP.100, CMP112: SM1/SB1 plug connector


Adjustable Radial

9288496267

CMP.71 – CMP.100, CMP112: SMB/SBB plug connector


Adjustable Radial

9288498187
19381212/EN – 03/2015

322 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Motor types
Standard type – connection options 11
CMP100, CMP112: Plug connectors SMC/SBC

X 1 3

11

18014405627737355

The power connector size S.C is not available as adjustable type. It can be ordered in
3 positions (positions X, 1, 3). If not specified otherwise in the order, the power con-
nector is supplied in position 3 (standard position). The signal connector is adjustable.
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 323


11 Motor types
Standard type – connection options

11.3.3 Power cables and plug connectors for CMP motors


Cable type Connector Thread Cable cross section Part number
type size Prefabricated ca- Replacement mating
bles connector *
Fixed installation Motor cable SM11 M23 4 x 1.5 mm2 05904544 01986740
SM12 4 x 2.5 mm2 05904552 01986740
SM14 4 x 4 mm2 05904560 01991639
SMB6 M40 4 x 6 mm2 13350269 13349856
SMB10 4 x 10 mm2 13350277 13349864
2
SMB16 4 x 16 mm 13350285 13349872
SMC16 M58 4 x 16 mm2 18148476 18150349
Brakemotor ca- SB11 M23 4 x 1.5 mm2 + 2 x 1 mm2 13354345 01986740
ble1) BP brake SB12 4 x 2.5 mm2 + 2 x 1 mm2 13354353 01986740
SB14 4 x 4 mm2 + 2 x 1 mm2 13354361 01991639
SBB6 M40 4 x 6 mm2 + 2 x 1.5 mm2 13350196 13349856
SBB10 4 x 10 mm2 + 2 x 1.5 mm2 13350218 13349864
SBB16 4 x 16 mm2 + 2 x 1.5 mm2 13350226 13349872
Brakemotor ca- SBC16 M58 4 x 16 mm2 + 3 x 1.5 mm2 18148514 18150349
ble BY brake
Cable carrier in- Motor cable SM11 M23 4 x 1.5 mm2 05906245 01986740
stallation SM12 4 x 2.5 mm2 05906253 01989197
SM14 4 x 4 mm2 05904803 01991639
SMB6 M40 4 x 6 mm2 13350293 13349856
SMB10 4 x 10 mm2 13350307 13349864
SMB16 4 x 16 mm2 13350315 13349872
SMC16 M58 4 x 16 mm2 18148484 18150349
SMC25 4 x 25 mm2 18148581 18150160
SMC35 4 x 35 mm2 18148697 18150179
Brakemotor ca- SB11 M23 4 x 1.5 mm2 + 2 x 1 mm2 13354388 01989197
ble2) BP brake SB12 4 x 2.5 mm2 + 2 x 1 mm2 13354396 01989197
SB14 4 x 4 mm2 + 2 x 1 mm2 13421603 01991639
SBB6 M40 4 x 6 mm2 + 2 x 1.5 mm2 13350234 13349856
SBB10 4 x 10 mm2 + 2 x 1.5 mm2 13350242 13349864
SBB16 4 x 16 mm2 + 2 x 1.5 mm2 13350250 13349872
Brakemotor ca- SBC16 M58 4 x 16 mm2 + 3 x 1.5 mm2 18148522 18150349
ble BY brake
1) BP brake:3-core cable, only 2 cores are used
2) BP brake:3-core cable, only 2 cores are used

* The complete connector service pack always includes the following parts:
• Power connector
• Insulation inserts
• Socket contacts
19381212/EN – 03/2015

324 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Motor types
Standard type – connection options 11
11.3.4 Power cables and plug connectors for CMPZ motors
Cable type Connector Thread Cable cross section Part number
type size mm2 Prefabricated ca- Replacement mating
bles connector *
Fixed installation Motor cable SM11 M23 4 x 1.5 mm2 05904544 01986740
SM12 4 x 2.5 mm2 05904552 01986740
SM14 4 x 4 mm2 05904560 01991639
SMB6 M40 4 x 6 mm2 13350269 13349856
SMB10 4 x 10 mm2 13350277 13349864
2
SMB16 4 x 16 mm 13350285 13349872
Brakemotor ca- SB11 M23 4 x 1.5 mm2 + 3 x 1 mm2 13354272 01986740
ble BY brake SB12 4 x 2.5 mm2 + 3 x 1 mm2 13354280 01986740
SB14 4 x 4 mm2 + 3 x 1 mm2 13354299 01991639
SBB6 M40 4 x 6 mm2 + 3 x 1.5 mm2 13350129 13349856
SBB10 4 x 10 mm2 + 3 x 1.5 mm2 13350137 13349864 11
SBB16 4 x 16 mm2 + 3 x 1.5 mm2 13350145 13349872
Cable carrier in- Motor cable SM11 M23 4 x 1.5 mm2 05906245 01986740
stallation SM12 4 x 2.5 mm2 05906253 01989197
SM14 4 x 4 mm2 05904803 01991639
SMB6 M40 4 x 6 mm2 13350293 13349856
SMB10 4 x 10 mm2 13350307 13349864
SMB16 4 x 16 mm2 13350315 13349872
2 2
Brakemotor ca- SB11 M23 4 x 1.5 mm + 3 x 1 mm 13354302 01989197
ble BY brake SB12 4 x 2.5 mm2 + 3 x 1 mm2 13354310 01989197
SB14 4 x 4 mm2 + 3 x 1 mm2 13354329 01991639
SBB6 M40 4 x 6 mm2 + 3 x 1.5 mm2 13350153 13349856
SBB10 4 x 10 mm2 + 3 x 1.5 mm2 13350161 13349864
SBB16 4 x 16 mm2 + 3 x 1.5 mm2 13350188 13349872

* The complete connector service pack always includes the following parts:
• Power connector
• Insulation inserts
• Socket contacts
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 325


11 Motor types
Standard type – connection options

11.3.5 Plug connector connection option – technical data


Illustration of the mating connectors:
[1] [2] [3]

4816072075

[1] Radial mating connector


[2] Angled mating connector
[3] Mating connector for forced cooling fan

Key
[C] [D]
[A] [B] [A] [B]

8790995467

[A] View A
[B] View B
[C] Customer connector with socket contacts
[D] Flange socket with pin contacts installed at the factory

NOTICE
Damage to the BK brake.
Possible damage to property.
• It is essential that you observe the correct polarity of BK brake supply. Check the
polarity when replacing the brake.

19381212/EN – 03/2015

326 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Standard type – connection options
Motor types
11
SM1/SB1 power connector (M23)

Wiring diagram with/without BP/BK brake


[1] [A] [B] BK=BU-
BK BU BP=YE
BK (3)
-/ D 3
W W1
3 D
BK (1)
+/ C GNYE GNYE C
[1]
4 4
BK RD
V V1 BK=RD+
B B BP=YE
A 1 BK BK 1 A
U U1
8790987787

[1] BP/BK brake (optional)

Connection of power plug connector SM1 / SB1 (M23) 11

Wiring diagram with/without BY brake


BU
[1] [A] [B]
BK BU RD
W W1
BK (3) D 3 3 D
15
C GNYE GNYE C
BK (1) WH
13
4 4
BK RD
14 BK (2) V V1
B B [1]
[2] A 1 BK BK 1 A
U U1
8790989707

[1] BY brake (optional)


[2] Connection to SEW rectifier according to operating instructions

Connection of SMB/SBB power plug connector (M40)

Wiring diagram with/without BP brake


[1] [A] [B]
BK (1) YE
13
BK (3) V V
15 [1]
- + BK RD + -
[2] V V1
W U U W
BK YE
BK
2 1 U U1 1 2

GNYE GNYE

BK BU
W W1
8791076107

[1] BP brake (optional)


[2] Connection to SEW rectifier according to operating instructions
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 327


11 Motor types
Standard type – connection options

Connection of SMB/SBB power plug connector (M40)

Wiring diagram with/without BY brake


[1] [A] [B]
RD
BU
BK (1)
[2] 13

BK (3) V V
15
- + BK RD + -
14
BK (2) V V1 W
[1]
W U U WH
BK BK
1 U U1 1
2 GNYE 2
GNYE

BK BU
W W1

8791078027

[1] BY brake (optional)


[2] Connection to SEW rectifier according to operating instructions. For BY.D, connection 14 is omitted.

Connection of SMC/SBC power plug connector (M58)

Wiring diagram with/without BY brake


[B]
RD
[1] [A] BU

13 BK (1)
BK (3) V V
15
- + BK RD + -
BK (2) V
14 W U
V1 U W WH
BK BK [1]
[2] 2 U U1 2
1 GNYE 1
GNYE

BK BU
W W1
8791074187

[1] BY brake (optional)


[2] Brake coil

19381212/EN – 03/2015

328 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Motor types
Standard type – connection options 11
Wiring diagram for RH1M resolver signal plug connectors

Wiring diagram
[A] [1] [2] [B]
PK BNVT RD (BK) RDWH
1 9 KTY+ (TF) 9 1
R1 (Referenz +)
8 8
GY BKWH
2 7 7 2 R2 (Referenz -)
WHBK 10 12 12 10 BU (BK)
3 6 6 3 KTY- (TF) [2]
RD 4 11 5 GN BU 11 RD
S4 (Sinus -) 5 4 S1 (Cosinus +)
BU YE YE BK
S2 (Sinus +) S3 (Cosinus -)
8790991627

[1] Shield connected to the metal housing of the connector. Colors according to SEW-EURODRIVE ca-
bles
[2] KTY+ (RD), KTY-(BU), optional TF (BK)
11
Pin assignment of plug connector lower part

Pin Color code Connection


1 RD/WH R1 (reference +)
2 BK/WH R2 (reference -)
3 RD S1 (cosine +)
4 BK S3 (cosine –)
5 YE S2 (sine +)
6 BU S4 (sine –)
7 – –
8 – –
9 RD KTY +
10 BU KTY –
11 – –
12 – –
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 329


11 Motor types
Standard type – connection options

Connection of signal plug connectors, AK0H, EK0H, AK1H, EK1H encoders

Wiring diagram
[1] [2]
[A] [B]
BN RD (BK)
KTY+ (TF)
BK BK
1 9 D+ 9 1

8 VT VT 8
2 7 D- 7 2

WH 10 12 RDBU; GY GY 12 10 BU (BK)
KTY- (TF) [2]
3 6 Us 6 3
11 11
RD GN GN RD
4 5 S4 (Sinus -) 5 4 S1 (Cosinus +)
BU YE YE BU
S2 (Sinus +) S3 (Cosinus -)
GYPK; PK PK
GND
8790993547

[1] Shield connected to the metal housing of the connector. Colors according to SEW‑EURODRIVE ca-
bles
[2] KTY+ (RD), KTY-(BU), optional TF (BK)

Pin assignment of plug connector lower part

Pin Color code Connection


1 – –
2 – –
3 RD S1 (cosine +)
4 BU S3 (cosine –)
5 YE S2 (sine +)
6 GN S4 (sine –)
7 VT D–
8 BK D+
9 RD KTY +
10 BU KTY –
11 PK Voltage reference (GND)
12 GY Supply voltage Vs
19381212/EN – 03/2015

330 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Motor types
Standard type – connection options 11
11.3.6 KK and KKS terminal box connection option

11
2900866059

Connection cross section

Motor type Power connection Encoder / resolver /


thermal motor protection
Connection Maximum Cable entry Connection Cable entry
connection
cross sec-
tion
CMP50, CMP63 Spring termi- 6 mm2 M25 Spring terminals M20
nals
CMP71, CMP80 M6 stud 10 mm2 M32 M16
2
CMP100 M8 stud 25 mm M40
CMP112S/M/L M8 stud 35 mm2 M50
2
CMP112H/E M10 stud 50 mm M50
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 331


11 Motor types
Standard type – connection options

11.3.7 Connection of CMP50 and CMP63

4a 5a 10 9 8 7 6 5 4 3 2 1
PE W V U

2900869771

Power

Pin Core identification Connection


U (BK/WH) U
V Black with white lettering U, V, W V
W W
PE (GN/YE) Green/yellow PE conduc-
tor

BP brake, BK brake

Auxiliary Core identification BMV brake rectifi- BS brake control-


terminal er connection ler connection
BP BK
contacts
4a + + 13 3
(RD) (YE) Yellow (RD) Red
5a – – 15 5
(BU) (YE) Yellow (BU) Blue
The brake has a standard supply voltage of DC 24 V.
19381212/EN – 03/2015

NOTICE
Damage to the BK brake.
Possible damage to property.
• It is essential that you observe the correct polarity of BK brake supply. Check the
polarity when replacing the brake.

332 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Motor types
Standard type – connection options 11
Signal

Resolver Encoder
1 ref + Reference 1 cos + Cosine
2 ref - 2 ref cos Reference
3 cos + Cosine 3 sin + Sine
4 cos - 4 ref sin Reference
5 sin + Sine 5 D- DATA
6 sin - 6 D+ DATA
7 - – 7 GND Ground
8 - – 8 Us Supply voltage
11
9 KTY + / (TF) Motor protection 9 KTY + / (TF) Motor protection
10 KTY - / (TF) 10 KTY - / (TF)
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 333


11 Motor types
Standard type – connection options

11.3.8 CMP71 – CMP112 connection

3a 3a
4a 4a
5a 5a
W

W
1
2
3
4

V
V

5
6
7
U

U
8
9
10

[1]
[2]
9007202155616523

[1] KK terminal box


[2] KKS terminal box

Power rating

Pin Core identification Connection


U (BK/WH) U
V Black with white lettering U, V, W V
W W
PE (GN/YE) Green/yellow PE conduc-
tor

BP brake

Auxiliary ter- Core identification BMV brake rectifi- BS brake controller


minal con- er connection connection
tacts
4a (BK/WH) 13 3
5a Black with white 15 5
lettering 1, 2, 3
19381212/EN – 03/2015

The brake has a standard supply voltage of DC 24 V.

334 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Motor types
Standard type – connection options 11
BY brake

Auxiliary Core identification Connection of Connecting the


terminal BME, BMP, BMH, BSG brake control
contacts BMK brake rectifi- unit
ers
3a (BK/WH) 14 1
4a Black with white 13 3
lettering 1, 2, 3
5a 15 5

Signal

Resolver Encoder
11
1 ref + Reference 1 cos + Cosine
2 ref – 2 ref cos Reference
3 cos + Cosine 3 sin + Sine
4 cos – 4 ref sin Reference
5 sin + Sine 5 D– DATA
6 sin – 6 D+ DATA
7 – – 7 GND Ground
8 – – 8 Us Supply voltage
9 KTY + / (TF) Motor protection 9 KTY + / (TF) Motor protection
10 KTY – / (TF) 10 KTY – / (TF)

11.3.9 Connection option via terminal box


The following figure shows the power connection in the terminal box.
[1]
[6]
[2]

[3]

[7]

[4]
[5] [8]

9007202155623307
19381212/EN – 03/2015

[1] Terminal studs [5] Terminal board


[2] Upper nut [6] Customer's cable
[3] Washer [7] Bottom nut
[4] Motor cable [8] Lock washer
For designing the terminal box, positions 4, 6 and 7 are regarded as current-carrying.

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 335


11 Motor types
Additional feature – forced-cooling fan

11.4 Additional feature – forced-cooling fan


Type designation: /VR

11.4.1 Description
Synchronous servomotors can be equipped with a forced cooling fan if requested. The
VR forced cooling fan is available for DC 24 V (CMP50 to CMP112, CMPZ71 to
CMPZ100).
A forced cooling fan can be retrofitted to these motors later using a retrofit set.
For CMPZ71 to CMPZ100 motors, the forced cooling fan /VR option can no longer be
combined with the manual brake release /HR option.

INFORMATION
The forced cooling fan can only be used up to a maximum oscillation and shock load
of 1 g.

INFORMATION
Before retrofitting a forced cooling fan, it is important to check whether the previously
used motor plug connectors/cables are permitted for the increased current consump-
tion.

11.4.2 Mechanical installation


Mounting the fan guard for the VR forced cooling fan:

Motor Bolts Tightening torque


CMP50, CMP63 M4 × 8 self-tapping 4 Nm
CMP.71 M6 × 20 4 Nm 1)
CMP.80, CMP.100 M8 × 20 10 Nm1)
CMP112 M10 x 25 15 Nm1)
1) Additional Loctite thread locking compound

19381212/EN – 03/2015

2903413131

336 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Motor types
Additional feature – forced-cooling fan 11
11.4.3 Electrical connection
The VR forced cooling fan is only available for DC 24 V voltage.
• DC 24 V ± 20%
• Plug connector connection
• Maximum connection cross section 2 x 1 mm2
• Pg7 cable gland with 7 mm inside diameter

- 2
DC 24 V
+ 1

Connector contact Connection


1 24 V +
11
2 0V

11.4.4 Retrofit set for CMP50 / CMP63

INFORMATION
The forced cooling fan retrofit set for motors CMP50 to CMP63 may only be mounted
by staff authorized by SEW‑EURODRIVE.

11.4.5 Forced cooling fan – technical data

Forced cooling fan type VR


Motor size CMP50 CMP63 CMP.71 CMP.80 CMP.100 CMP112
Supply voltage DC 24 V ± 20%
Current consumption DC 0.15 A 0.25 A 0.88 A 0.88 A 1.67 A 1.67 A
Power consumption 3.5 W 6W 21 W 21 W 40 W 40 W
Air discharge rate 56 m3/h 80 m3/h 275 m3/h 275 m3/h 540 m3/h 540 m3/h
Ambient temperature -20 °C to 60 °C
Degree of protection IP54 / IP55
Electrical connection Plug connector
Max. cable cross section 3 × 1 mm2
Inner diameter of the cable gland 7 mm
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 337


11 Motor types
Additional feature – forced-cooling fan

UWU52A switched-mode power supply


The AC voltage type includes a VR forced cooling fan and the UWU52A switched-
mode power supply.
Input: AC 110 to 240 V; 1.04 to 0.63 A; 50/60 Hz
Output: DC 24 V; 2.5 A (40 °C); 2.0 A (55 °C)
Connection screw terminals 0.2 to 2.5 mm2, separable.
Degree of protection: IP20; attachment to EN 60715 TH35 support rail in the control
cabinet.
Part number: 0188 1817.
Dimensions of the UWU52A switched-mode power supply:

76
101 38
111

4816285067

Part numbers of forced cooling fan, complete

Forced cooling fan for motor type Part number


CMP50 13328697
CMP63 13327569
CMP71 13337114
CMP.71 /BP1 /BY2 16447697
CMP80 16444841
CMP80 /BP3 16447751
CMPZ80 /BY4 16447735
CMP100 16444973
CMP.100 /BP5 /BY8 16447808
CMP112 16452178
CMP112 /BY14 16452194
19381212/EN – 03/2015

338 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Motor types
Additional feature – forced-cooling fan 11
Retrofit set for CMP50 to 100

INFORMATION
The forced cooling fan retrofit set for CMP50 to CMP63 motors may only be mounted
by staff authorized by SEW‑EURODRIVE.

The forced cooling fan retrofit set is supplied as follows:


• Forced cooling fan, cpl.
• Accessory bag

Retrofit set
Content Part number
CMP50 VR kit
11
Forced cooling fan, cpl.
Machine screw M4x8-Tx-ST-A2F
Lock washer
Housing cover CMP50 / AS1H / ES1H / RH1M 13332414
Bolt
Washer
Housing cover seal for CMP50

Retrofit set
Content Part number
CMP63 VR kit
Forced cooling fan, cpl.
Machine screw M4x8-Tx-ST-A2F
Lock washer
Housing cover CMP63 / AS1H / ES1H / RH1M 13332422
Bolt
Washer
Housing cover gasket for CMP63

Retrofit set
Content Part number Part number
CMP71 VR kit CMP.71 /BP1 /BY2
Forced cooling fan, cpl.
Cap screw M6x20‑8.8‑ADB3
Grommet 13355228 13355236
19381212/EN – 03/2015

Sleeve
Washer

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 339


11 Motor types
Additional feature – forced-cooling fan

Retrofit set
Content Part number Part number Part number
CMP80 VR kit CMP80 /BP3 CMPZ80 /BY4
Forced cooling fan, cpl.
Cap screw M6x20‑8.8‑ADB3
Grommet 13355244 13355252 13355260
Sleeve
Washer

Retrofit set
Content Part number Part number
CMP100 VR kit CMP.100 /BP5 /BY8
Forced cooling fan, cpl.
Cap screw M6x20‑8.8‑ADB3
Grommet 13355279 13355287
Sleeve
Washer

Retrofit set
Content Part number Part number
CMP112 CMP112 /BY14
Forced cooling fan, cpl.
Cap screw M10x25-8.8-A2F
Damping plate 13368354 13368362
Sleeve
Washer

19381212/EN – 03/2015

340 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Description 12
12 Prefabricated cables
12.1 Description
SEW‑EURODRIVE offers prefabricated cables with plugs for straightforward and relia-
ble motor connection.
Cable and contact are connected using the crimp technique. The following cables are
available in steps of 1 m:
• Motor cables
• Brakemotor cables
• Resolver/motor protection cables
• Absolute encoder/motor protection cables
• Forced cooling fan cables
Prefabricated cables are divided into: 12
• Power cables (motor cable, brakemotor cable, extension cable)
• Feedback cables (encoder cable, extension cable).

12.1.1 Preselection of cables


Prefabricated cables were preselected by SEW-EURODRIVE according to the stand-
ard EN 60204. The routing types "fixed installation" and "cable carrier installation"
were considered.
Using other standards for the machine construction can result in diverging cross sec-
tions.

INFORMATION
If the system requires UL approval, then the power cables between motor and inver-
ter must have a minimum cross section of 2.5 mm2 (AWG14) according to
NEC430.22 (National Fire Protection Association; Edition 2011).
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 341


12 Prefabricated cables
Project planning for cable cross section

12.2 Project planning for cable cross section


12.2.1 Cable dimensioning to EN 60204
The following figure shows the minimum required cable cross section depending on
cable length and current.
l [m]
150

35 mm²
130
25 mm²
16 mm²
10 mm²
110
6 mm²
100
4 mm²
90
2,5 mm²

1,5 mm²
70

50

30
0 10 20 30 40 50 60 70 80 90 100 110 120 130

I [A]
18014403327547531
2 2
Prefabricated cables with cross sections of 1.5 mm to 35 mm can be ordered from
SEW‑EURODRIVE.
Prefabricated brakemotor cables are available with a cross section of up to 16 mm2.

19381212/EN – 03/2015

342 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Project planning for cable cross section 12
12.2.2 Cable load table
Cable load through current I in ampere according to EN 60204‑1 (edition 2006) ta-
ble 6, ambient temperature 40 °C.

Cable cross sec- Three-core Three-core Three-core


tion sheathed cable in sheathed cable on sheathed cable
pipe or cable (B2) top of each other lined up horizon-
on wall (C) tally (E)
mm2 A A A
1.5 13.1 15.2 16.1
2.5 17.4 21. 22
4 23 28 30
6 30 36 37
10 40 50 52 12
16 54 66 70
25 70 84 88
35 86 104 110
50 103 125 133
70 130 160 171
These data are merely recommended values and are no substitute for the detailed
project planning of the incoming cables depending on the specific application consid-
ering the applicable regulations.
Observe the voltage drop along the cable in particular with the DC 24 V brake coil
when dimensioning the cross sections for the brake cable. The acceleration current is
decisive for the calculation.

12.2.3 General information on cable assignment tables


The values in the cable assignment tables are based on the values with a gray back-
ground in the "Cable load tables" (→ 2 343).
You find the connector assignment in the assignment tables of Connectors and termi-
nal boxes (→ 2 316).
The limitation of the cable lengths results from the standard specifications relating to
the voltage drop at I0 / I0VR (< 5 %) for cables according to EN60204-1 (edition 2008)
and from the derating of the plug connectors.
If the system requires UL approval, then the power cables between motor and inverter
must have a minimum cross section of 2.5 mm2 (AWG14) according to NEC430.22
(National Fire Protection Association; Edition 2011).
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 343


12 Prefabricated cables
Cable assignment: CMP and CMPZ, 400 V system voltage

12.3 Cable assignment: CMP and CMPZ, 400 V system voltage


The part numbers refer to the smallest connector that can be used:
• 1.5 mm2 to 4 mm2: SM1
• 6 mm2 to 16 mm2: SMB
• 16 mm2 to 35 mm2: SMC
Motor Rated speed Standstill to cable Core cross Plug con- Cable part no.
current I0 length section nector Fixed Cable carrier in- Cable carrier
routing stallation extension1)
rpm A m mm2 Stand-alone motor
CMP40S 3000 1.2 100 1.5 SM1 05904544 05906245 13332457
CMP40S 4500 1.2 100 1.5 SM1 05904544 05906245 13332457
CMP40S 6000 1.2 100 1.5 SM1 05904544 05906245 13332457
CMP40M 3000 0.95 100 1.5 SM1 05904544 05906245 13332457
CMP40M 4500 0.95 100 1.5 SM1 05904544 05906245 13332457
CMP40M 6000 1.1 100 1.5 SM1 05904544 05906245 13332457
CMP50S 3000 0.96 100 1.5 SM1 05904544 05906245 13332457
CMP50S 4500 1.32 100 1.5 SM1 05904544 05906245 13332457
CMP50S 6000 1.7 100 1.5 SM1 05904544 05906245 13332457
CMP50M 3000 1.68 100 1.5 SM1 05904544 05906245 13332457
CMP50M 4500 2.3 100 1.5 SM1 05904544 05906245 13332457
CMP50M 6000 3 100 1.5 SM1 05904544 05906245 13332457
CMP50L 3000 2.2 100 1.5 SM1 05904544 05906245 13332457
CMP50L 4500 3.15 100 1.5 SM1 05904544 05906245 13332457
CMP50L 6000 4.2 100 1.5 SM1 05904544 05906245 13332457
CMP63S 3000 2.15 100 1.5 SM1 05904544 05906245 13332457
CMP63S 4500 3.05 100 1.5 SM1 05904544 05906245 13332457
CMP63S 6000 3.9 100 1.5 SM1 05904544 05906245 13332457
CMP63M 3000 3.6 100 1.5 SM1 05904544 05906245 13332457
CMP63M 4500 5.4 100 1.5 SM1 05904544 05906245 13332457
CMP63M 6000 6.9 100 1.5 SM1 05904544 05906245 13332457
CMP63L 3000 4.95 100 1.5 SM1 05904544 05906245 13332457
CMP63L 4500 6.9 100 1.5 SM1 05904544 05906245 13332457
CMP63L 6000 9.3 75 1.5 SM1 05904544 05906245 13332457
CMP63L 6000 9.3 100 2.5 SM1 05904552 05906253 13332465
CMP.71S 2000 3.4 100 1.5 SM1 05904544 05906245 13332457
CMP.71S 3000 4.9 100 1.5 SM1 05904544 05906245 13332457
CMP.71S 4500 7.3 95 1.5 SM1 05904544 05906245 13332457
CMP.71S 4500 7.3 100 2.5 SM1 05904552 05906253 13332465
CMP.71S 6000 9.6 70 1.5 SM1 05904544 05906245 13332457
CMP.71S 6000 9.6 100 2.5 SM1 05904552 05906253 13332465
CMP.71M 2000 5 100 1.5 SM1 05904544 05906245 13332457
CMP.71M 3000 7.5 90 1.5 SM1 05904544 05906245 13332457
CMP.71M 3000 7.5 100 2.5 SM1 05904552 05906253 13332465
CMP.71M 4500 10.9 65 1.5 SM1 05904544 05906245 13332457
CMP.71M 4500 10.9 100 2.5 SM1 05904552 05906253 13332465
CMP.71M 6000 14.7 80 2.5 SM1 05904552 05906253 13332465
19381212/EN – 03/2015

CMP.71M 6000 14.7 100 4 SM1 05904560 05904803 13332473


CMP.71L 2000 6.3 100 1.5 SM1 05904544 05906245 13332457
CMP.71L 3000 9.4 80 1.5 SM1 05904544 05906245 13332457
CMP.71L 3000 9.4 100 2.5 SM1 05904552 05906253 13332465
CMP.71L 4500 14.1 85 2.5 SM1 05904552 05906253 13332465
CMP.71L 4500 14.1 100 4 SM1 05904560 05904803 13332473
CMP.71L 6000 18.8 100 4 SM1 05904560 05904803 13332473
CMP.80S 2000 6.9 100 1.5 SM1 05904544 05906245 13332457

344 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Cable assignment: CMP and CMPZ, 400 V system voltage 12
Motor Rated speed Standstill to cable Core cross Plug con- Cable part no.
current I0 length section nector Fixed Cable carrier in- Cable carrier
routing stallation extension1)
rpm A m mm2 Stand-alone motor
CMP.80S 3000 10 70 1.5 SM1 05904544 05906245 13332457
CMP.80S 3000 10 100 2.5 SM1 05904552 05906253 13332465
CMP.80S 4500 15.3 80 2.5 SM1 05904552 05906253 13332465
CMP.80S 4500 15.3 100 4 SM1 05904560 05904803 13332473
CMP.80S 6000 20 95 4 SM1 05904560 05904803 13332473
CMP.80S 6000 20 100 6 SMB 13350269 13350293 13350021
CMP.80M 2000 9.3 75 1.5 SM1 05904544 05906245 13332457
CMP.80M 2000 9.3 100 2.5 SM1 05904552 05906253 13332465
CMP.80M 3000 13.4 90 2.5 SM1 05904552 05906253 13332465
CMP.80M 3000 13.4 100 4 SM1 05904560 05904803 13332473
CMP.80M 4500 20.1 95 4 SM1 05904560 05904803 13332473
CMP.80M 4500 20.1 100 6 SMB 13350269 13350293 13350021
CMP.80M 6000 26.4 100 6 SMB 13350269 13350293 13350021 12
CMP.80L 2000 12.5 90 2.5 SM1 05904552 05906253 13332465
CMP.80L 2000 12.5 100 4 SM1 05904560 05904803 13332473
CMP.80L 3000 18.7 100 4 SM1 05904560 05904803 13332473
CMP.80L 4500 27.8 100 6 SMB 13350269 13350293 13350021
CMP.80L 6000 37.6 100 10 SMB 13350277 13350307 13350048
CMP.100S 2000 13.3 85 2.5 SM1 05904552 05906253 13332465
CMP.100S 2000 13.3 100 4 SM1 05904560 05904803 13332473
CMP.100S 3000 19.6 95 4 SM1 05904560 05904803 13332473
CMP.100S 3000 19.6 100 6 SMB 13350269 13350293 13350021
CMP.100S 4500 30 98 6 SMB 13350269 13350293 13350021
CMP.100S 4500 30 100 10 SMB 13350277 13350307 13350048
CMP.100M 2000 14.7 75 2.5 SM1 05904552 05906253 13332465
CMP.100M 2000 14.7 100 4 SM1 05904560 05904803 13332473
CMP.100M 3000 21.8 85 4 SM1 05904560 05904803 13332473
CMP.100M 3000 21.8 100 6 SMB 13350269 13350293 13350021
CMP.100M 4500 33.1 90 6 SMB 13350269 13350293 13350021
CMP.100M 4500 33.1 100 10 SMB 13350277 13350307 13350048
CMP.100L 2000 21.8 100 6 SMB 13350269 13350293 13350021
CMP.100L 3000 32.3 90 6 SMB 13350269 13350293 13350021
CMP.100L 3000 32.3 100 10 SMB 13350277 13350307 13350048
CMP.100L 4500 48.4 98 10 SMB 13350277 13350307 13350048
CMP.100L 4500 48.4 100 16 SMC 18148476 18148484 18156819
CMP112S 2000 14.3 70 2.5 SM1 05904552 05906253 13332465
CMP112S 2000 14.3 100 4 SM1 05904560 05904803 13332473
CMP112S 3000 21 80 4 SM1 05904560 05904803 13332473
CMP112S 3000 21 100 6 SMB 13350269 13350293 13350021
CMP112S 4500 31.5 80 6 SMB 13350269 13350293 13350021
CMP112S 4500 31.5 100 10 SMB 13350277 13350307 13350048
CMP112M 2000 21 80 4 SM1 05904560 05904803 13332473
CMP112M 2000 21 100 6 SMB 13350269 13350293 13350021
CMP112M 3000 32 80 6 SMB 13350269 13350293 13350021
19381212/EN – 03/2015

CMP112M 3000 32 100 10 SMB 13350277 13350307 13350048


CMP112M 4500 47 90 10 SMB 13350277 13350307 13350048
CMP112M 4500 47 100 16 SMB 13350285 13350315 13350056
CMP112M 4500 47 100 16 SMC 18148476 18148484 18156819
CMP112L 2000 33 75 6 SMB 13350269 13350293 13350021
CMP112L 2000 33 100 10 SMB 13350277 13350307 13350048
CMP112L 3000 49 85 10 SMB 13350277 13350307 13350048
CMP112L 3000 49 100 16 SMB 13350285 13350315 13350056

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 345


12 Prefabricated cables
Cable assignment: CMP and CMPZ, 400 V system voltage

Motor Rated speed Standstill to cable Core cross Plug con- Cable part no.
current I0 length section nector Fixed Cable carrier in- Cable carrier
routing stallation extension1)
rpm A m mm2 Stand-alone motor
CMP112L 3000 49 100 16 SMC 18148476 18148484 18156819
CMP112L 4500 73 100 25 SMC – 18148581 18156827
CMP112H 2000 38 100 10 SMB 13350277 13350307 13350048
CMP112H 3000 57 100 16 SMC 18148476 18148484 18156819
CMP112H 4500 86 100 35 SMC – 18148697 18156835
CMP112E 2000 44.5 90 10 SMB 13350277 13350307 13350048
CMP112E 2000 44.5 100 16 SMB 13350285 13350315 13350056
CMP112E 2000 44.5 100 16 SMC 18148476 18148484 18156819
CMP112E 3000 65 80 16 SMC 18148476 18148484 18156819
CMP112E 3000 65 100 25 SMC – 18148581 18156827
CMP112E 4500 98 100 35 – – – –
1) Currently only cable carrier extension cables are offered

19381212/EN – 03/2015

346 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Cable assignment: CMP /VR and CMPZ /VR, 400 V system voltage 12
12.4 Cable assignment: CMP /VR and CMPZ /VR, 400 V system voltage
The part numbers refer to the smallest connector that can be used:
• 1.5 mm2 to 4 mm2: SM1
• 6 mm2 to 16 mm2: SMB
• 16 mm2 to 35 mm2: SMC
Motor Rated Standstill To cable Core cross Plug con- Cable part no.
speed current I0 length section nector Fixed Cable carrier Cable carrier ex-
routing installation tension1)
rpm A m mm2 Stand-alone motor
CMP50S /VR 3000 1.25 100 1.5 SM1 05904544 05906245 13332457
CMP50S /VR 4500 1.7 100 1.5 SM1 05904544 05906245 13332457
CMP50S /VR 6000 2.2 100 1.5 SM1 05904544 05906245 13332457
CMP50M /VR 3000 2.45 100 1.5 SM1 05904544 05906245 13332457
CMP50M /VR 4500 3.35 100 1.5 SM1 05904544 05906245 13332457
CMP50M /VR 6000 4.4 100 1.5 SM1 05904544 05906245 13332457 12
CMP50L /VR 3000 3.2 100 1.5 SM1 05904544 05906245 13332457
CMP50L /VR 4500 4.6 100 1.5 SM1 05904544 05906245 13332457
CMP50L /VR 6000 6.1 100 1.5 SM1 05904544 05906245 13332457
CMP63S /VR 3000 3 100 1.5 SM1 05904544 05906245 13332457
CMP63S /VR 4500 4.2 100 1.5 SM1 05904544 05906245 13332457
CMP63S /VR 6000 5.4 100 1.5 SM1 05904544 05906245 13332457
CMP63M /VR 3000 5.1 100 1.5 SM1 05904544 05906245 13332457
CMP63M /VR 4500 7.6 90 1.5 SM1 05904544 05906245 13332457
CMP63M /VR 4500 7.6 100 2.5 SM1 05904552 05906253 13332465
CMP63M /VR 6000 9.8 70 1.5 SM1 05904544 05906245 13332457
CMP63M /VR 6000 9.8 100 2.5 SM1 05904552 05906253 13332465
CMP63L /VR 3000 7.2 95 1.5 SM1 05904544 05906245 13332457
CMP63L /VR 3000 7.2 100 2.5 SM1 05904552 05906253 13332465
CMP63L /VR 4500 10 70 1.5 SM1 05904544 05906245 13332457
CMP63L /VR 4500 10 100 2.5 SM1 05904552 05906253 13332465
CMP63L /VR 6000 13.5 85 2.5 SM1 05904552 05906253 13332465
CMP63L /VR 6000 13.5 100 4 SM1 05904560 05904803 13332473
CMP.71S /VR 2000 4.6 100 1.5 SM1 05904544 05906245 13332457
CMP.71S /VR 3000 6.7 100 1.5 SM1 05904544 05906245 13332457
CMP.71S /VR 4500 9.9 70 1.5 SM1 05904544 05906245 13332457
CMP.71S /VR 4500 9.9 100 2.5 SM1 05904552 05906253 13332465
CMP.71S /VR 6000 13.1 85 2.5 SM1 05904552 05906253 13332465
CMP.71S /VR 6000 13.1 100 4 SM1 05904560 05904803 13332473
CMP.71M /VR 2000 7.3 95 1.5 SM1 05904544 05906245 13332457
CMP.71M /VR 2000 7.3 100 2.5 SM1 05904552 05906253 13332465
CMP.71M/VR 3000 10.9 60 1.5 SM1 05904544 05906245 13332457
CMP.71M /VR 3000 10.9 100 2.5 SM1 05904552 05906253 13332465
CMP.71M /VR 4500 15.9 70 2.5 SM1 05904552 05906253 13332465
CMP.71M /VR 4500 15.9 100 4 SM1 05904560 05904803 13332473
CMP.71M /VR 6000 21.5 85 4 SM1 05904560 05904803 13332473
CMP.71M /VR 6000 21.5 100 6 SMB 13350269 13350293 13350021
19381212/EN – 03/2015

CMP.71L /VR 2000 10.1 65 1.5 SM1 05904544 05906245 13332457


CMP.71L /VR 2000 10.1 100 2.5 SM1 05904552 05906253 13332465
CMP.71L /VR 3000 15.1 75 2.5 SM1 05904552 05906253 13332465
CMP.71L /VR 3000 15.1 100 4 SM1 05904560 05904803 13332473
CMP.80S /VR 2000 9.5 70 1.5 SM1 05904544 05906245 13332457
CMP.80S /VR 2000 9.5 100 2.5 SM1 05904552 05906253 13332465
CMP.80S /VR 3000 13.8 80 2.5 SM1 05904552 05906253 13332465
CMP.80S /VR 3000 13.8 100 4 SM1 05904560 05904803 13332473

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 347


12 Prefabricated cables
Cable assignment: CMP /VR and CMPZ /VR, 400 V system voltage

Motor Rated Standstill To cable Core cross Plug con- Cable part no.
speed current I0 length section nector Fixed Cable carrier Cable carrier ex-
routing installation tension1)
rpm A m mm2 Stand-alone motor
CMP.80S /VR 4500 21 85 4 SM1 05904560 05904803 13332473
CMP.80S /VR 4500 21 100 6 SMB 13350269 13350293 13350021
CMP.80S /VR 6000 27.5 100 6 SMB 13350269 13350293 13350021
CMP.80M /VR 2000 13.4 85 2.5 SM1 05904552 05906253 13332465
CMP.80M /VR 2000 13.4 100 4 SM1 05904560 05904803 13332473
CMP.80M /VR 3000 19.3 95 4 SM1 05904560 05904803 13332473
CMP.80M /VR 3000 19.3 100 6 SMB 13350269 13350293 13350021
CMP.80M /VR 4500 29 95 6 SMB 13350269 13350293 13350021
CMP.80M /VR 4500 29 100 10 SMB 13350277 13350307 13350048
CMP.80M /VR 6000 38 100 10 SMB 13350277 13350307 13350048
CMP.80L /VR 2000 20 90 4 SM1 05904560 05904803 13332473
CMP.80L /VR 2000 20 100 6 SMB 13350269 13350293 13350021
CMP.80L /VR 3000 30 90 6 SMB 13350269 13350293 13350021
CMP.80L /VR 3000 30 100 10 SMB 13350277 13350307 13350048
CMP.80L /VR 4500 44.5 100 10 SMB 13350277 13350307 13350048
CMP.100S /VR 2000 18.8 95 4 SM1 05904560 05904803 13332473
CMP.100S /VR 2000 18.8 100 6 SMB 13350269 13350293 13350021
CMP.100S /VR 3000 27.5 100 6 SMB 13350269 13350293 13350021
CMP.100S /VR 4500 42.5 100 10 SMB 13350277 13350307 13350048
CMP.100M /VR 2000 22.3 100 6 SMB 13350269 13350293 13350021
CMP.100M /VR 3000 33 85 6 SMB 13350269 13350293 13350021
CMP.100M /VR 3000 33 100 10 SMB 13350277 13350307 13350048
CMP.100M /VR 4500 72 100 35 SMC – 18148697 –
CMP.100M/ VR 4500 50 100 16 SMB 13350285 13350315 13350056
CMP.100M/ VR 4500 50 100 16 SMC 18148476 18148484 18156819
CMP.100L /VR 2000 32.5 85 6 SMB 13350269 13350293 13350021
CMP.100L /VR 2000 32.5 100 10 SMB 13350277 13350307 13350048
CMP.100L /VR 3000 48 95 10 SMB 13350277 13350307 13350048
CMP.100L /VR 3000 48 100 16 SMB 13350285 13350315 13350056
CMP.100L/VR 4500 72 100 25 SMC – 18148581 18156827
CMP112S/ VR 2000 21 80 4 SM1 05904560 05904803 13332473
CMP112S/ VR 2000 21 100 6 SMB 13350269 13350293 13350021
CMP112S/ VR 3000 30.5 80 6 SMB 13350269 13350293 13350021
CMP112S/ VR 3000 30.5 100 10 SMB 13350277 13350307 13350048
CMP112S/ VR 4500 45.5 90 10 SMB 13350277 13350307 13350048
CMP112S/ VR 4500 45.5 100 16 SMB 13350285 13350315 13350056
CMP112S/ VR 4500 45.5 100 16 SMC 18148476 18148484 18156819
CMP112M/ VR 2000 32 80 6 SMB 13350269 13350293 13350021
CMP112M/ VR 2000 32 100 10 SMB 13350277 13350307 13350048
CMP112M/ VR 3000 49 85 10 SMB 13350277 13350307 13350048
CMP112M/ VR 3000 49 100 16 SMB 13350285 13350315 13350056
CMP112M/ VR 3000 49 100 16 SMC 18148476 18148484 18156819
CMP112M/ VR 4500 72 100 25 SMC – 18148581 18156827
CMP112L/ VR 2000 52 100 16 SMC 18148476 18148484 18156819
19381212/EN – 03/2015

CMP112L/ VR 3000 77 100 25 SMC – 18148581 18156827


CMP112L/ VR 4500 114 100 50 – – – –
CMP112H/ VR 2000 57 100 16 SMC 18148476 18148484 18156819
CMP112H/ VR 3000 84 100 35 SMC – 18148697 18156835
CMP112H/ VR 4500 128 100 50 – – – –
CMP112E/ VR 2000 71 100 25 SMC – 18148581 18156827
CMP112E/ VR 3000 104 100 35 – – – –

348 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Cable assignment: CMP /VR and CMPZ /VR, 400 V system voltage 12
Motor Rated Standstill To cable Core cross Plug con- Cable part no.
speed current I0 length section nector Fixed Cable carrier Cable carrier ex-
routing installation tension1)
rpm A m mm2 Stand-alone motor
CMP112E/ VR 4500 156 100 50 – – – –
1) Currently only cable carrier extension cables are offered

12
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 349


12 Prefabricated cables
Cable assignment: CMP /BP /BK, 400 V system voltage

12.5 Cable assignment: CMP /BP /BK, 400 V system voltage


The part numbers refer to the smallest connector that can be used:
• 1.5 mm2 to 4 mm2: SB1
• 6 mm2 to 16 mm2: SBB
Motor Rated Standstill To cable Core cross Plug con- Cable part no.
speed current I0 length section nector Fixed Cable carrier in- Cable carrier ex-
routing stallation tension1)
rpm A m mm2 Brakemotor
CMP40S /BK 3000 1.2 100 1.5 SB1 13354345 13354388 13354221
CMP40S /BK 4500 1.2 100 1.5 SB1 13354345 13354388 13354221
CMP40S /BK 6000 1.2 100 1.5 SB1 13354345 13354388 13354221
CMP40M /BK 3000 0.95 100 1.5 SB1 13354345 13354388 13354221
CMP40M /BK 4500 0.95 100 1.5 SB1 13354345 13354388 13354221
CMP40M /BK 6000 1.1 100 1.5 SB1 13354345 13354388 13354221
CMP50S /BK 3000 0.96 100 1.5 SB1 13354345 13354388 13354221
CMP50S /BK 4500 1.32 100 1.5 SB1 13354345 13354388 13354221
CMP50S /BK 6000 1.7 100 1.5 SB1 13354345 13354388 13354221
CMP50M /BK 3000 1.68 100 1.5 SB1 13354345 13354388 13354221
CMP50M /BK 4500 2.3 100 1.5 SB1 13354345 13354388 13354221
CMP50M /BK 6000 3 100 1.5 SB1 13354345 13354388 13354221
CMP50L /BK 3000 2.2 100 1.5 SB1 13354345 13354388 13354221
CMP50L /BK 4500 3.15 100 1.5 SB1 13354345 13354388 13354221
CMP50L /BK 6000 4.2 100 1.5 SB1 13354345 13354388 13354221
CMP63S /BK 3000 2.15 100 1.5 SB1 13354345 13354388 13354221
CMP63S /BK 4500 3.05 100 1.5 SB1 13354345 13354388 13354221
CMP63S /BK 6000 3.9 100 1.5 SB1 13354345 13354388 13354221
CMP63M /BK 3000 3.6 100 1.5 SB1 13354345 13354388 13354221
CMP63M /BK 4500 5.4 100 1.5 SB1 13354345 13354388 13354221
CMP63M /BK 6000 6.9 100 1.5 SB1 13354345 13354388 13354221
CMP63L /BK 3000 4.95 100 1.5 SB1 13354345 13354388 13354221
CMP63L /BK 4500 6.9 100 1.5 SB1 13354345 13354388 13354221
CMP63L /BK 6000 9.3 75 1.5 SB1 13354345 13354388 13354221
CMP63L /BK 6000 9.3 100 2.5 SB1 13354353 13354396 13354248
CMP71S /BP 2000 3.4 80 1.5 SB1 13354345 13354388 13354221
CMP71S /BP 3000 4.9 80 1.5 SB1 13354345 13354388 13354221
CMP71S /BP 4500 7.3 80 1.5 SB1 13354345 13354388 13354221
CMP71S /BP 4500 7.3 80 2.5 SB1 13354353 13354396 13354248
CMP71S /BP 6000 9.6 70 1.5 SB1 13354345 13354388 13354221
CMP71S /BP 6000 9.6 80 2.5 SB1 13354353 13354396 13354248
CMP71M /BP 2000 5 80 1.5 SB1 13354345 13354388 13354221
CMP71M /BP 3000 7.5 80 1.5 SB1 13354345 13354388 13354221
CMP71M /BP 3000 7.5 80 2.5 SB1 13354353 13354396 13354248
CMP71M /BP 4500 10.9 65 1.5 SB1 13354345 13354388 13354221
CMP71M /BP 4500 10.9 80 2.5 SB1 13354353 13354396 13354248
CMP71M /BP 6000 14.7 80 2.5 SB1 13354353 13354396 13354248
CMP71M /BP 6000 14.7 80 4 SB1 13354361 13421603 13354337
19381212/EN – 03/2015

CMP71L /BP 2000 6.3 80 1.5 SB1 13354345 13354388 13354221


CMP71L /BP 3000 9.4 80 1.5 SB1 13354345 13354388 13354221
CMP71L /BP 3000 9.4 80 2.5 SB1 13354353 13354396 13354248
CMP71L /BP 4500 14.1 80 2.5 SB1 13354353 13354396 13354248
CMP71L /BP 4500 14.1 80 4 SB1 13354361 13421603 13354337
CMP71L /BP 6000 18.8 80 4 SB1 13354361 13421603 13354337
CMP80S /BP 2000 6.9 55 1.5 SB1 13354345 13354388 13354221
CMP80S /BP2) 3000 10 55 1.5 SB1 1335 4345 1335 4388 1335 4221

350 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Cable assignment: CMP /BP /BK, 400 V system voltage 12
Motor Rated Standstill To cable Core cross Plug con- Cable part no.
speed current I0 length section nector Fixed Cable carrier in- Cable carrier ex-
routing stallation tension1)
rpm A m mm2 Brakemotor
CMP80S /BP 3000 10 55 2.5 SB1 1335 4353 1335 4396 1335 4248
CMP80S /BP 4500 15.3 55 2.5 SB1 1335 4353 1335 4396 1335 4248
CMP80S /BP 4500 15.3 55 4 SB1 1335 4361 13421603 1335 4337
CMP80M /BP 2000 9.3 55 1.5 SB1 1335 4345 1335 4388 1335 4221
CMP80M /BP 2000 9.3 55 2.5 SB1 1335 4353 1335 4396 1335 4248
CMP80M /BP 3000 13.4 55 2.5 SB1 1335 4353 1335 4396 1335 4248
CMP80M /BP 3000 13.4 55 4 SB1 1335 4361 13421603 1335 4337
CMP80M /BP 4500 20.1 55 4 SB1 1335 4361 13421603 1335 4337
CMP80M /BP 4500 20.1 85 6 SBB 1335 0196 1335 0234 1335 0099
CMP80L /BP 2000 12.5 55 2.5 SB1 1335 4353 1335 4396 1335 4248
CMP80L /BP 2000 12.5 55 4 SB1 1335 4361 13421603 1335 4337
CMP80L /BP 3000 18.7 55 4 SB1 1335 4361 13421603 1335 4337
CMP80L /BP 4500 27.8 85 6 SB1 1335 0196 1335 0234 1335 0099 12
CMP100S /BP 2000 13.3 45 2.5 SB1 1335 4353 1335 4396 1335 4248
CMP100S /BP 2000 13.3 45 4 SB1 1335 4361 13421603 1335 4337
CMP100S /BP 3000 19.6 45 4 SB1 1335 4361 13421603 1335 4337
CMP100S /BP 3000 19.6 70 6 SBB 1335 0196 1335 0234 1335 0099
CMP100S /BP 4500 30 70 6 SBB 1335 0196 1335 0234 1335 0099
CMP100S /BP 4500 30 70 10 SBB 1335 0218 1335 0242 1335 0102
CMP100M /BP 2000 14.7 45 2.5 SB1 1335 4353 1335 4396 1335 4248
CMP100M /BP 2000 14.7 45 4 SB1 1335 4361 13421603 1335 4337
CMP100M /BP 3000 21.8 45 4 SB1 1335 4361 13421603 1335 4337
CMP100M /BP 3000 21.8 70 6 SBB 1335 0196 03350234 1335 0099
CMP100M /BP 4500 33.1 70 6 SBB 1335 0196 1335 0234 1335 0099
CMP100M /BP 4500 33.1 70 10 SBB 1335 0218 1335 0242 1335 0102
CMP100L /BP 2000 21.8 70 6 SBB 1335 0196 1335 0234 1335 0099
CMP100L /BP 3000 32.3 70 6 SBB 1335 0196 1335 0234 1335 0099
CMP100L /BP 3000 32.3 70 10 SBB 1335 0218 1335 0242 1335 0102
CMP100L /BP 4500 48.4 70 10 SBB 1335 0218 1335 0242 1335 0102
CMP100L /BP 4500 48.4 70 16 SBB 1335 0226 1335 0250 1335 0110
1) Currently only cable carrier extension cables are offered
2) The maximum cable length can be increased to 70 m or 85 m if a cable with a core cross section of 6 mm is used (change from SB1
to SBB). In this case, the brake cable cross section increases from 1 mm to 1.5 mm
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 351


12 Prefabricated cables
Cable assignment: CMP /BP / BK /VR, 400 V system voltage

12.6 Cable assignment: CMP /BP / BK /VR, 400 V system voltage


The part numbers refer to the smallest connector that can be used:
• 1.5 mm2 to 4 mm2: SB1
• 6 mm2 to 16 mm2: SBB
Motor Rated Standstill To cable Core Plug con- Cable part no.
speed current I0 length cross nector Fixed Cable carrier Cable carrier ex-
section routing installation tension1)
rpm A m mm2 Brakemotor
CMP50S /BK /VR 3000 1.25 100 1.5 SB1 13354345 13354388 13354221
CMP50S /BK /VR 4500 1.7 100 1.5 SB1 13354345 13354388 13354221
CMP50S /BK /VR 6000 2.2 100 1.5 SB1 13354345 13354388 13354221
CMP50M /BK. /VR 3000 2.45 100 1.5 SB1 13354345 13354388 13354221
CMP50M /BK /VR 4500 3.35 100 1.5 SB1 13354345 13354388 13354221
CMP50M /BK /VR 6000 4.4 100 1.5 SB1 13354345 13354388 13354221
CMP50L /BK /VR 3000 3.2 100 1.5 SB1 13354345 13354388 13354221
CMP50L /BK /VR 4500 4.6 100 1.5 SB1 13354345 13354388 13354221
CMP50L /BK /VR 6000 6.1 100 1.5 SB1 13354345 13354388 13354221
CMP63S /BK /VR 3000 3 100 1.5 SB1 13354345 13354388 13354221
CMP63S /BK /VR 4500 4.2 100 1.5 SB1 13354345 13354388 13354221
CMP63S /BK /VR 6000 5.4 100 1.5 SB1 13354345 13354388 13354221
CMP63M /BK /VR 3000 5.1 100 1.5 SB1 13354345 13354388 13354221
CMP63M /BK /VR 4500 7.6 90 1.5 SB1 13354345 13354388 13354221
CMP63M /BK /VR 4500 7.6 100 2.5 SB1 13354353 13354396 13354248
CMP63M /BK /VR 6000 9.8 70 1.5 SB1 13354345 13354388 13354221
CMP63M /BK /VR 6000 9.8 100 2.5 SB1 13354353 13354396 13354248
CMP63L /BK /VR 3000 7.2 95 1.5 SB1 13354345 13354388 13354221
CMP63L /BK /VR 3000 7.2 100 2.5 SB1 13354353 13354396 13354248
CMP63L /BK /VR 4500 10 70 1.5 SB1 13354345 13354388 13354221
CMP63L /BK /VR 4500 10 100 2.5 SB1 13354353 13354396 13354248
CMP63L /BK /VR 6000 13.5 85 2.5 SB1 13354353 13354396 13354248
CMP63L /BK /VR 6000 13.5 100 4 SB1 13354361 13421603 13354337
CMP71S /BP /VR 2000 4.6 80 1.5 SB1 13354345 13354388 13354221
CMP71S /BP /VR 3000 6.7 80 1.5 SB1 13354345 13354388 13354221
CMP71S /BP /VR 4500 9.9 70 1.5 SB1 13354345 13354388 13354221
CMP71S /BP /VR 4500 9.9 80 2.5 SB1 13354353 13354396 13354248
CMP71S /BP /VR 6000 13.1 80 2.5 SB1 13354353 13354396 13354248
CMP71S /BP /VR 6000 13.1 80 4 SB1 13354361 13421603 13354337
CMP71M /BP /VR 2000 7.3 80 1.5 SB1 13354345 13354388 13354221
CMP71M /BP /VR 2000 7.3 80 2.5 SB1 13354353 13354396 13354248
CMP71M /BP /VR 3000 10.9 60 1.5 SB1 13354345 13354388 13354221
CMP71M /BP /VR 3000 10.9 80 2.5 SB1 13354353 13354396 13354248
CMP71M /BP /VR 4500 15.9 70 2.5 SB1 13354353 13354396 13354248
CMP71M /BP /VR 4500 15.9 80 4 SB1 13354361 13421603 13354337
CMP71M /BP /VR 6000 21.5 80 4 SB1 13354361 13421603 13354337
CMP71L /BP /VR 2000 10.1 65 1.5 SB1 13354345 13354388 13354221
CMP71L /BP /VR 2000 10.1 100 2.5 SB1 13354353 13354396 13354248
19381212/EN – 03/2015

CMP71L /BP /VR 3000 15.1 75 2.5 SB1 13354353 13354396 13354248
CMP71L /BP /VR 3000 15.1 80 4 SB1 13354361 13421603 13354337
CMP80S /BP /VR 2000 9.5 55 1.5 SB1 13354345 13354388 13354221
CMP80S /BP /VR 2000 9.5 55 2.5 SB1 13354353 13354396 13354248
2)
CMP80S /BP /VR 3000 13.8 55 2.5 SB1 13354353 13354396 13354248
CMP80S /BP /VR 3000 13.8 55 4 SB1 13354361 13421603 13354337
CMP80S /BP /VR 4500 21 55 4 SB1 13354361 13421603 13354337
CMP80S /BP /VR 4500 21 85 6 SBB 13350196 13350234 13350099

352 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Cable assignment: CMP /BP / BK /VR, 400 V system voltage 12
Motor Rated Standstill To cable Core Plug con- Cable part no.
speed current I0 length cross nector Fixed Cable carrier Cable carrier ex-
section routing installation tension1)
rpm A m mm2 Brakemotor
CMP80M /BP /VR 2000 13.4 55 2.5 SB1 13354353 13354396 13354248
CMP80M /BP /VR 2000 13.4 50 4 SB1 13354361 13421603 13354337
CMP80M /BP /VR 3000 19.3 55 4 SB1 13354361 13421603 13354337
CMP80M /BP /VR 3000 19.3 85 6 SBB 13350196 13350234 13350099
CMP80M /BP /VR 4500 29 85 6 SBB 13350196 13350234 13350099
CMP80M /BP /VR 4500 29 85 10 SBB 13350218 13350242 13350102
CMP80L /BP /VR 2000 20 55 4 SB1 13354361 13421603 13354337
CMP80L /BP /VR 2000 20 85 6 SBB 13350196 13350234 13350099
CMP80L /BP /VR 3000 30 85 6 SBB 13350196 13350234 13350099
CMP80L /BP /VR 3000 30 85 10 SBB 13350218 13350242 13350102
CMP80L /BP /VR 4500 44.5 85 10 SBB 13350218 13350242 13350102
CMP100S /BP /VR 2000 18.8 45 4 SB1 13354361 13421603 13354337
CMP100S /BP /VR 2000 18.8 70 6 SBB 13350196 13350234 13350099 12
CMP100S /BP /VR 3000 27.5 70 6 SBB 13350196 13350234 13350099
CMP100S /BP /VR 4500 42.5 70 10 SBB 13350218 13350242 13350102
CMP100M /BP /VR 2000 22.3 70 6 SBB 13350196 13350234 13350099
CMP100M /BP /VR 3000 33 70 6 SBB 13350196 13350234 13350099
CMP100M /BP /VR 3000 33 70 10 SBB 13350218 13350242 13350102
CMP100L /BP /VR 2000 32.5 70 6 SBB 13350196 13350234 13350099
CMP100L /BP /VR 2000 32.5 70 10 SBB 13350218 13350242 13350102
CMP100L /BP /VR 3000 48 70 10 SBB 13350218 13350242 13350102
CMP100L /BP /VR 3000 48 70 16 SBB 13350226 13350250 13350110
1) Currently only cable carrier extension cables are offered
2) The maximum cable length can be increased to 70 m or 85 m if a cable with a core cross section of 6 mm is used (change from SB1
to SBB connector). In this case, the brake cable cross section increases from 1 mm to 1.5 mm.
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 353


12 Prefabricated cables
Cable assignment: CMP /BY, 400 V system voltage

12.7 Cable assignment: CMP /BY, 400 V system voltage


The following table allows for selecting power cables for CMP servo brakemotors with
a system voltage of 400 V and a BY brake with 400 V, 230 V or 110 V brake voltage.
An additional length for 110 V is specified in parenthesis for cases where the permit-
ted cable length for 110 V is shorter than for 400 V/230 V.
The part numbers refer to the smallest connector that can be used:
• 1.5 mm2 to 4 mm2: SB1
• 6 mm2 to 16 mm2: SBB
• 16 mm2 to 35 mm2: SBC
Motor Rated speed Standstill To cable Core Plug con- Cable part no.
current I0 length cross sec- nector Fixed Cable carrier Cable carrier
tion routing installation extension1)
rpm A m mm2 Brakemotor
CMP112S/ BY 2000 14.3 50 2.5 SB1 13354280 13354310 13354248
CMP112S/ BY 3000 21 50 4 SB1 13354299 13354329 13354337
CMP112S/ BY 4500 31.5 80 6 SBB 13350129 13350153 13350099
CMP112M/ BY 2000 21 50 4 SB1 13354299 13354329 13354337
CMP112M/ BY 3000 32 80 6 SBB 13350129 13350153 13350099
CMP112M/ BY 4500 47 80 10 SBB 13350137 13350161 13350102
CMP112L/ BY 2000 33 75 6 SBB 13350129 13350153 13350099
CMP112L/ BY 2000 33 80 10 SBB 13350137 13350161 13350102
CMP112L/ BY 3000 49 80 10 SBB 13350137 13350161 13350102
CMP112L/ BY 4500 73 80 25 SBC – – –
CMP112H/ BY 2000 38 80 10 SBB 13350137 13350161 13350102
CMP112H/ BY 3000 57 80 16 SBC 18148514 18148522 18156843
CMP112H/ BY 4500 86 80 35 – – – –
CMP112E/ BY 2000 44.5 80 10 SBB 13350137 13350161 13350102
CMP112E/ BY 3000 65 80 16 SBC 18148514 18148522 18156843
CMP112E/ BY 4500 98 80 35 – – – –
1) Currently only cable carrier extension cables are offered

Permitted cable lengths for DC 24 V BY working brakes are especially reduced. Note
the following guidelines:
CMP112 /BY: between 4 and 6 m depending on the cable cross section
For project planning with DC 24 V BY working brake, consult SEW‑EURODRIVE.
19381212/EN – 03/2015

354 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Cable assignment: CMP /BY /VR, 400 V system voltage 12
12.8 Cable assignment: CMP /BY /VR, 400 V system voltage
The following table allows for selecting power cables for CMP servo brakemotors with
a system voltage of 400 V and a BY brake with 400 V, 230 V or 110 V brake voltage.
An additional length for 110 V is specified in parenthesis for cases where the permit-
ted cable length for 110 V is shorter than for 400 V/230 V.
The part numbers refer to the smallest connector that can be used:
• 1.5 mm2 to 4 mm2: SB1
• 6 mm2 to 16 mm2: SBB
• 16 mm2 to 35 mm2: SBC
Motor Rated Standstill To cable Core Plug con- Cable part no.
speed current I0 length cross nector Fixed Cable carrier Cable carrier
section routing installation extension1)
rpm A m mm2 Brakemotor
CMP112S/ BY/ VR 2000 21 50 4 SB1 13354299 13354329 13354337
12
CMP112S/ BY/ VR 3000 30.5 80 6 SBB 13350137 13350153 13350099
CMP112S/ BY/ VR 4500 45.5 80 10 SBB 13350137 13350161 13350102
CMP112M/ BY/ VR 2000 32 80 6 SBB 13350137 13350153 13350099
CMP112M/ BY/ VR 3000 49 80 10 SBB 13350137 13350161 13350102
CMP112M/ BY/ VR 4500 72 80 25 SBC – – –
CMP112L/BY/ VR 2000 52 80 16 SBC 18148514 18148522 18156843
CMP112L/BY/ VR 3000 77 80 25 SBC – – –
CMP112L/BY/ VR 4500 114 80 50 – – – –
CMP112H/ BY/ VR 2000 57 80 16 SBC 18148514 18148522 18156843
CMP112H/ BY/ VR 3000 84 80 35 SBC – – –
CMP112H/ BY/ VR 4500 128 80 50 – – – –
CMP112E/ BY/ VR 2000 71 80 25 SBC – – –
CMP112E/ BY/ VR 3000 104 80 35 – – – –
CMP112E/ BY/ VR 4500 156 80 50 – – – –
1) Currently only cable carrier extension cables are offered

Permitted cable lengths for DC 24 V BY working brakes are especially reduced. Note
the following guidelines:
CMP112 /BY: between 4 and 6 m depending on the cable cross section
For project planning with DC 24 V BY working brake, consult SEW‑EURODRIVE.
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 355


12 Prefabricated cables
Cable assignment: CMPZ /BY, 400 V system voltage

12.9 Cable assignment: CMPZ /BY, 400 V system voltage


The following table allows for selecting power cables for CMP servo brakemotors with
a system voltage of 400 V and a BY brake with 400 V, 230 V or 110 V brake voltage.
An additional length for 110 V is specified in parenthesis for cases where the permit-
ted cable length for 110 V is shorter than for 400 V/230 V.
The part numbers refer to the smallest connector that can be used:
• 1.5 mm2 to 4 mm2: SM1
• 6 mm2 to 16 mm2: SMB
• 16 mm2 to 35 mm2: SMC
Motor Rated Standstill To cable Core Plug con- Cable part no.
speed current I0 length cross sec- nector Fixed Cable carrier Cable carrier ex-
tion routing installation tension1)
rpm A m mm2 Brakemotor
CMPZ71S /BY 2000 3.4 100 1.5 SM1 13354272 13354302 13354221
CMPZ71S /BY 3000 4.9 100 1.5 SM1 13354272 13354302 13354221
CMPZ71S /BY 4500 7.3 96 1.5 SM1 13354272 13354302 13354221
CMPZ71S /BY 4500 7.3 100 2.5 SM1 13354280 13354310 13354248
CMPZ71S /BY 6000 9.6 73 1.5 SM1 13354272 13354302 13354221
CMPZ71S /BY 6000 9.6 100 2.5 SM1 13354280 13354310 13354248
CMPZ71M /BY 2000 5 100 1.5 SM1 13354272 13354302 13354221
CMPZ71M /BY 3000 7.5 93 1.5 SM1 13354272 13354302 13354221
CMPZ71M /BY 3000 7.5 100 2.5 SM1 13354280 13354310 13354248
CMPZ71M /BY 4500 10.9 64 1.5 SM1 13354272 13354302 13354221
CMPZ71M /BY 4500 10.9 100 2.5 SM1 1335 4280 13354310 13354248
CMPZ71M /BY 6000 14.7 79 2.5 SM1 1335 4280 13354310 13354248
CMPZ71M /BY 6000 14.7 100 4 SM1 1335 4299 13354329 13354337
CMPZ71L /BY 2000 6.3 100 1.5 SM1 1335 4272 13354302 13354221
CMPZ71L /BY 3000 9.4 74 1.5 SM1 1335 4272 13354302 13354221
CMPZ71L /BY 3000 9.4 100 2.5 SM1 1335 4280 13354310 13354248
CMPZ 71L /BY 4500 14.1 83 2.5 SM1 1335 4280 13354310 13354248
CMPZ 71L /BY 4500 14.1 100 4 SM1 1335 4299 13354329 13354337
CMPZ71L /BY 6000 18.8 100 4 SM1 1335 4299 13354329 13354337
CMPZ80S /BY 2000 6.9 100 1.5 SM1 1335 4272 13354302 13354221
CMPZ80S /BY 3000 10 70 1.5 SM1 1335 4272 13354302 13354221
CMPZ80S /BY 3000 10 100 (75) 2.5 SM1 1335 4280 13354310 13354248
CMPZ80S /BY 4500 15.3 76 (75) 2.5 SM1 1335 4280 13354310 13354248
CMPZ80S /BY 4500 15.3 100 (75) 4 SM1 1335 4299 13354329 13354337
CMPZ80M /BY 2000 9.3 75 1.5 SM1 1335 4272 13354302 13354221
CMPZ80M /BY 2000 9.3 100 2.5 SM1 1335 4280 13354310 13354248
CMPZ80M /BY 3000 13.4 87 (75) 2.5 SM1 1335 4280 13354310 13354248
CMPZ80M /BY 3000 13.4 100 (75) 4 SM1 1335 4299 13354329 13354337
CMPZ80M /BY 4500 20.1 93 (75) 4 SM1 1335 4299 13354329 13354337
CMPZ80M /BY 4500 20.1 100 6 SMB 1335 0129 13350153 13350099
CMPZ80L /BY 2000 12.5 93 2.5 SM1 1335 4280 13354310 13354248
CMPZ80L /BY 2000 12.5 100 4 SM1 1335 4299 13354329 13354337
19381212/EN – 03/2015

CMPZ80L /BY 3000 18.7 100 (75) 4 SM1 1335 4299 13354329 13354337
CMPZ80L /BY 4500 27.8 100 6 SMB 1335 0129 13350153 13350099
CMPZ100S /BY 2000 13.3 88 2.5 SM1 1335 4280 13354310 13354248
CMPZ100S /BY 2000 13.3 100 4 SM1 1335 4299 13354329 13354337
CMPZ100S /BY 3000 19.6 95 (55) 4 SM1 1335 4299 13354329 13354337
CMPZ100S /BY 3000 19.6 100 (80) 6 SMB 1335 0129 13350153 13350099
CMPZ100S /BY 4500 30 93 (80) 6 SMB 1335 0129 13350153 13350099
CMPZ100S /BY 4500 30 100 (80) 10 SMB 1335 0137 13350161 13350102

356 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Cable assignment: CMPZ /BY, 400 V system voltage 12
Motor Rated Standstill To cable Core Plug con- Cable part no.
speed current I0 length cross sec- nector Fixed Cable carrier Cable carrier ex-
tion routing installation tension1)
rpm A m mm2 Brakemotor
CMPZ100M /BY 2000 14.7 79 2.5 SM1 1335 4280 13354310 13354248
CMPZ100M /BY 2000 14.7 100 4 SM1 1335 4299 13354329 13354337
CMPZ100M /BY 3000 21.8 85 (55) 4 SM1 1335 4299 13354329 13354337
CMPZ100M /BY 3000 21.8 100 (80) 6 SMB 1335 0129 13350153 13350099
CMPZ100M /BY 4500 33.1 84 (80) 6 SMB 13350129 13350153 13350099
CMPZ100M /BY 4500 33.1 100 (80) 10 SMB 13350137 13350161 13350102
CMPZ100L /BY 2000 21.8 85 4 SM1 13354299 13354329 13354337
CMPZ100L /BY 2000 21.8 100 6 SMB 13350129 13350153 13350099
CMPZ100L /BY 3000 32.3 87 (80) 6 SMB 13350129 13350153 13350099
CMPZ100L /BY 3000 32.3 100 (80) 10 SMB 13350137 13350161 13350102
CMPZ100L /BY 4500 48.4 96 (80) 10 SMB 13350137 13350161 13350102
CMPZ100L /BY 4500 48.4 100 (80) 16 SMB 13350145 13350188 13350110
CMPZ100L /BY 4500 48.4 100 (80) 16 SBC 18148514 18148522 18156843 12
1) Currently only cable carrier extension cables are offered

Permitted cable lengths for DC 24 V BY working brakes are especially reduced. Note
the following guidelines:
CMPZ71 . /BY: maximum 8 m
CMPZ80 . between 6.4 and 9 m depending on the cable cross section
CMPZ100 . /BY: between 4.5 and 7 m depending on the cable cross section
For project planning with DC 24 V BY working brake, consult SEW‑EURODRIVE.
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 357


12 Prefabricated cables
Cable assignment: CMPZ /BY /VR, 400 V system voltage

12.10 Cable assignment: CMPZ /BY /VR, 400 V system voltage


The following table allows for selecting power cables for CMP servo brakemotors with
a system voltage of 400 V and a BY brake with 400 V, 230 V or 110 V brake voltage.
An additional length for 110 V is specified in parenthesis for cases where the permit-
ted cable length for 110 V is shorter than for 400 V/230 V.
The part numbers refer to the smallest connector that can be used:
• 1.5 mm2 to 4 mm2: SB1
• 6 mm2 to 16 mm2: SBB
• 16 mm2 to 35 mm2: SBC
Motor Rated Standstill To cable Core Plug con- Cable part no.
speed current I0 length cross sec- nector Fixed Cable carrier Cable carrier ex-
tion routing installation tension1)
rpm A m mm2 Brakemotor
CMPZ71S /BY /VR 2000 4.6 100 1.5 SB1 13354272 13354302 13354221
CMPZ71S /BY /VR 3000 6.7 100 1.5 SB1 13354272 13354302 13354221
CMPZ71S /BY /VR 4500 9.9 70 1.5 SB1 13354272 13354302 13354221
CMPZ71S /BY /VR 4500 9.9 100 2.5 SB1 13354280 13354310 13354248
CMPZ71S /BY /VR 6000 13.1 89 2.5 SB1 13354280 13354310 13354248
CMPZ71S /BY /VR 6000 13.1 100 4 SB1 13354299 13354329 13354337
CMPZ71M /BY /VR 2000 7.3 96 1.5 SB1 13354272 13354302 13354221
CMPZ71M /BY /VR 2000 7.3 100 2.5 SB1 13354280 13354310 13354248
CMPZ71M /BY /VR 3000 10.9 64 1.5 SB1 13354272 13354302 13354221
CMPZ71M /BY /VR 3000 10.9 100 2.5 SB1 13354280 13354310 13354248
CMPZ71M /BY /VR 4500 15.9 73 2.5 SB1 13354280 13354310 13354248
CMPZ71M /BY /VR 4500 15.9 100 4 SB1 13354299 13354329 13354337
CMPZ71M /BY /VR 6000 21.5 85 4 SB1 13354299 13354329 13354337
CMPZ71M /BY /VR 6000 21.5 100 6 SBB 13350129 13350153 13350099
CMPZ71L /BY /VR 2000 10.1 69 1.5 SB1 13354272 13354302 13354221
CMPZ71L /BY /VR 2000 10.1 100 2.5 SB1 13354280 13354310 13354248
CMPZ71L /BY /VR 3000 15.1 76 2.5 SB1 13354280 13354310 13354248
CMPZ71L /BY /VR 3000 15.1 100 4 SB1 13354299 13354329 13354337
CMPZ 71L /BY /VR 4500 22.5 100 6 SBB 13350129 13350153 13350099
CMPZ71L /BY /VR 6000 30 93 6 SBB 13350129 13350153 13350099
CMPZ71L /BY /VR 6000 30 100 10 SB1 1335 0137 1335 0161 1335 0102
CMPZ80S /BY /VR 2000 9.5 73 1.5 SB1 13354272 13354302 13354221
CMPZ80S /BY /VR 2000 9.5 100 2.5 SB1 13354280 13354310 13354248
CMPZ80S /BY /VR 3000 13.8 84 2.5 SB1 13354280 13354310 13354248
CMPZ80S /BY /VR 3000 13.8 100 4 SB1 13354299 13354329 13354337
CMPZ80S /BY /VR 4500 21 89 4 SB1 13354299 13354329 13354337
CMPZ80S /BY /VR 4500 21 100 6 SBB 13350129 13350153 13350099
CMPZ80S /BY /VR 6000 27.5 100 6 SBB 13350129 13350153 13350099
CMPZ80M /BY /VR 2000 13.4 87 2.5 SB1 13354280 13354310 13354248
CMPZ80M /BY /VR 2000 13.4 100 4 SB1 13354299 13354329 13354337
CMPZ80M /BY /VR 3000 19.3 97 4 SB1 13354299 13354329 13354337
CMPZ80M /BY /VR 3000 19.3 100 6 SB1 13350129 13350153 13350099
19381212/EN – 03/2015

CMPZ80M /BY /VR 4500 29 96 6 SBB 13350129 13350153 13350099


CMPZ80M /BY /VR 4500 29 100 10 SBB 13350137 13350161 13350102
CMPZ80M /BY /VR 6000 38 100 10 SBB 13350137 13350161 13350102
CMPZ80L /BY /VR 2000 20 93 4 SB1 13354299 13354329 13354337
CMPZ80L /BY /VR 2000 20 100 6 SBB 13350129 13350153 13350099
CMPZ80L /BY /VR 3000 30 93 6 SBB 13350129 13350153 13350099
CMPZ80L /BY /VR 3000 30 100 10 SBB 13350137 13350161 13350102
CMPZ80L /BY /VR 4500 44.5 100 10 SBB 13350137 13350161 13350102

358 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Cable assignment: CMPZ /BY /VR, 400 V system voltage 12
Motor Rated Standstill To cable Core Plug con- Cable part no.
speed current I0 length cross sec- nector Fixed Cable carrier Cable carrier ex-
tion routing installation tension1)
rpm A m mm2 Brakemotor
CMPZ80L /BY /VR 6000 60 100 16 SBB 13350145 13350188 13350110
CMPZ100S /BY /VR 2000 18.8 100 4 SBB 13354299 13354329 13354337
CMPZ100S /BY /VR 3000 27.5 100 6 SBB 13350129 13350153 13350099
CMPZ100S /BY /VR 4500 42.5 100 10 SBB 13350137 13350161 13350102
CMPZ100M /BY /VR 2000 22.3 100 6 SBB 13350129 13350153 13350099
CMPZ100M /BY /VR 3000 33 84 6 SBB 13350129 13350153 13350099
CMPZ100M /BY /VR 3000 33 100 10 SBB 13350137 13350161 13350102
CMPZ100M /BY /VR 4500 50 100 16 SBC 18148514 18148522 18156843
CMPZ100L /BY /VR 2000 32.5 86 6 SBB 1335 0129 13350153 13350099
CMPZ100L /BY /VR 2000 32.5 100 10 SBB 1335 0137 13350161 13350102
CMPZ100L /BY /VR 3000 48 97 10 SBB 1335 0137 13350161 13350102
CMPZ100L /BY /VR 3000 48 100 16 SBB 1335 0145 13350188 13350110
CMPZ100L /BY /VR 3000 48 100 16 SBC 18148514 18148522 18156843 12
1) Currently only cable carrier extension cables are offered

Permitted cable lengths for DC 24 V BY working brakes are especially reduced. Note
the following guidelines:
CMPZ71 . /BY: maximum 8 m
CMPZ80 . /BY: between 6.4 and 9 m depending on the cable cross section
CMPZ100 . /BY: between 4.5 and 7 m depending on the cable cross section
For project planning with DC 24 V BY working brake, consult SEW‑EURODRIVE.
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 359


12 Prefabricated cables
Cable assignment: CMP and CMPZ, 230 V system voltage

12.11 Cable assignment: CMP and CMPZ, 230 V system voltage


The part numbers refer to the smallest connector that can be used:
• 1.5 mm2 to 4 mm2: SM1
• 6 mm2 to 16 mm2: SMB
Motor Rated Standstill To cable Core cross Plug con- Cable part no.
speed current I0 length section nector Fixed Cable carrier in- Cable carrier ex-
routing stallation tension1)
rpm A m mm2 Stand-alone motor
CMP40S 3000 1.2 100 1.5 SM1 05904544 05906245 13332457
CMP40S 4500 1.2 100 1.5 SM1 05904544 05906245 13332457
CMP40S 6000 1.36 100 1.5 SM1 05904544 05906245 13332457
CMP40M 3000 1.09 100 1.5 SM1 05904544 05906245 13332457
CMP40M 4500 1.5 100 1.5 SM1 05904544 05906245 13332457
CMP40M 6000 1.91 100 1.5 SM1 05904544 05906245 13332457
CMP50S 3000 1.65 100 1.5 SM1 05904544 05906245 13332457
CMP50S 4500 2.3 100 1.5 SM1 05904544 05906245 13332457
CMP50S 6000 3.07 100 1.5 SM1 05904544 05906245 13332457
CMP50M 3000 2.85 100 1.5 SM1 05904544 05906245 13332457
CMP50M 4500 4 100 1.5 SM1 05904544 05906245 13332457
CMP50M 6000 5.25 100 1.5 SM1 05904544 05906245 13332457
CMP50L 3000 3.84 100 1.5 SM1 05904544 05906245 13332457
CMP50L 4500 5.53 100 1.5 SM1 05904544 05906245 13332457
CMP50L 6000 7.6 100 1.5 SM1 05904544 05906245 13332457
CMP63S 3000 3.61 100 1.5 SM1 05904544 05906245 13332457
CMP63S 4500 5.25 100 1.5 SM1 05904544 05906245 13332457
CMP63S 6000 6.78 100 1.5 SM1 05904544 05906245 13332457
CMP63M 3000 6.35 100 1.5 SM1 05904544 05906245 13332457
CMP63M 4500 9.78 70 1.5 SM1 05904544 05906245 13332457
CMP63M 4500 9.78 100 2.5 SM1 05904552 05906253 13332465
CMP63M 6000 12.06 55 1.5 SM1 05904544 05906245 13332457
CMP63M 6000 12.06 100 4 SM1 05904560 05904803 13332473
CMP63L 3000 8.76 75 1.5 SM1 05904544 05906245 13332457
CMP63L 3000 8.76 100 2.5 SM1 05904552 05906253 13332465
CMP63L 4500 12.01 55 1.5 SM1 05904544 05906245 13332457
CMP63L 4500 12.01 100 4 SM1 05904560 05904803 13332473
CMP.71S 3000 8.7 75 1.5 SM1 05904544 05906245 13332457
CMP.71S 3000 8.7 100 2.5 SM1 05904552 05906253 13332465
CMP.71S 4500 12.8 90 2.5 SM1 05904552 05906253 13332465
CMP.71S 4500 12.8 100 4 SM1 05904560 05904803 13332473
CMP.71S 6000 17 100 4 SM1 05904560 05904803 13332473
CMP.71M 3000 13.1 85 2.5 SM1 05904552 05906253 13332465
CMP.71M 3000 13.1 100 4 SM1 05904560 05904803 13332473
CMP.71M 4500 19.2 95 4 SM1 05904560 05904803 13332473
CMP.71L 3000 16.8 100 4 SM1 05904560 05904803 13332473
CMP.80S 3000 17.7 100 4 SM1 05904560 05904803 13332473
CMP.80S 4500 27 100 6 SMB 13350269 13350293 13350021
19381212/EN – 03/2015

CMP.80S 6000 35.5 75 6 SMB 13350269 13350293 13350021


CMP.80S 6000 35.5 100 10 SMB 13350277 13350307 13350048
CMP.80M 3000 23.5 100 6 SMB 13350269 13350293 13350021
CMP.80M 4500 35 80 6 SMB 13350269 13350293 13350021
CMP.80M 4500 35 100 10 SMB 13350277 13350307 13350048
CMP.80M 6000 46.9 95 10 SMB 13350277 13350307 13350048
CMP.80M 6000 46.9 100 16 SMB 13350285 13350315 13350056
CMP.80L 3000 32.5 85 6 SMB 13350269 13350293 13350021

360 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Cable assignment: CMP and CMPZ, 230 V system voltage 12
Motor Rated Standstill To cable Core cross Plug con- Cable part no.
speed current I0 length section nector Fixed Cable carrier in- Cable carrier ex-
routing stallation tension1)
rpm A m mm2 Stand-alone motor
CMP.80L 3000 32.5 100 10 SMB 13350277 13350307 13350048
CMP.100S 3000 34.2 80 6 SMB 13350269 13350293 13350021
CMP.100S 3000 34.2 100 10 SMB 13350277 13350307 13350048
CMP.100M 3000 40 100 10 SMB 13350277 13350307 13350048
1) Currently only cable carrier extension cables are offered

12
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 361


12 Prefabricated cables
Cable assignment: CMP /VR and CMPZ /VR, 230 V system voltage

12.12 Cable assignment: CMP /VR and CMPZ /VR, 230 V system voltage
The part numbers refer to the smallest connector that can be used:
• 1.5 mm2 to 4 mm2: SM1
• 6 mm2 to 16 mm2: SMB
Motor Rated Standstill To cable Core Plug con- Cable part no.
speed current I0 length cross sec- nector Fixed Cable carrier in- Cable carrier ex-
tion routing stallation tension1)
rpm A m mm2 Stand-alone motor
CMP.71S /VR 3000 11.8 55 1.5 SM1 05904544 05906245 13332457
CMP.71S /VR 3000 11.8 100 4 SM1 05904560 05904803 13332473
CMP.71S /VR 4500 17.4 100 4 SM1 05904560 05904803 13332473
CMP.71S /VR 6000 23 80 4 SM1 05904560 05904803 13332473
CMP.71M /VR 3000 19.1 95 4 SM1 05904560 05904803 13332473
CMP.80S /VR 3000 24.5 100 6 SMB 13350269 13350293 13350021
CMP.80S /VR 4500 37 75 6 SMB 13350269 13350293 13350021
CMP.80S /VR 4500 37 100 10 SMB 13350277 13350307 13350048
CMP80S /VR 6000 48.5 95 10 SMB 13350277 13350307 13350048
CMP80S /VR 6000 48.5 100 16 SMB 13350285 13350315 13350056
CMP.80M /VR 3000 34 80 6 SMB 13350269 13350293 13350021
CMP.80M /VR 3000 34 100 10 SMB 13350277 13350307 13350048
1) Currently only cable carrier extension cables are offered

19381212/EN – 03/2015

362 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Cable assignment: CMP /BP /BK, 230 V system voltage 12
12.13 Cable assignment: CMP /BP /BK, 230 V system voltage
The part numbers refer to the smallest connector that can be used:
• 1.5 mm2 to 4 mm2: SB1
• 6 mm2 to 16 mm2: SBB
Motor Rated Standstill To cable Core Plug con- Cable part no.
speed current I0 length cross sec- nector Fixed Cable carrier Cable carrier ex-
tion routing installation tension1)
rpm A m mm2 Brakemotor
CMP40S /BK 3000 1.2 100 1.5 SB1 13354345 13354388 13354221
CMP40S /BK 4500 1.2 100 1.5 SB1 13354345 13354388 13354221
CMP40S /BK 6000 1.36 100 1.5 SB1 13354345 13354388 13354221
CMP40M /BK 3000 1.09 100 1.5 SB1 13354345 13354388 13354221
CMP40M /BK 4500 1.5 100 1.5 SB1 13354345 13354388 13354221
CMP40M /BK 6000 1.91 100 1.5 SB1 13354345 13354388 13354221
CMP50S /BK 3000 1.65 100 1.5 SB1 13354345 13354388 13354221
12
CMP50S /BK 4500 2.3 100 1.5 SB1 13354345 13354388 13354221
CMP50S /BK 6000 3.07 100 1.5 SB1 13354345 13354388 13354221
CMP50M /BK 3000 2.85 100 1.5 SB1 13354345 13354388 13354221
CMP50M /BK 4500 4 100 1.5 SB1 13354345 13354388 13354221
CMP50M /BK 6000 5.25 100 1.5 SB1 13354345 13354388 13354221
CMP50L /BK 3000 3.84 100 1.5 SB1 13354345 13354388 13354221
CMP50L /BK 4500 5.53 100 1.5 SB1 13354345 13354388 13354221
CMP50L /BK 6000 7.6 100 1.5 SB1 13354345 13354388 13354221
CMP63S /BK 3000 3.61 100 1.5 SB1 13354345 13354388 13354221
CMP63S /BK 4500 5.25 100 1.5 SB1 13354345 13354388 13354221
CMP63S /BK 6000 6.78 100 1.5 SB1 13354345 13354388 13354221
CMP63M /BK 3000 6.35 100 1.5 SB1 13354345 13354388 13354221
CMP63M /BK 4500 9.78 70 1.5 SB1 13354345 13354388 13354221
CMP63M /BK 4500 9.78 100 2.5 SB1 13354353 13354396 13354248
CMP63M /BK 6000 12.06 55 1.5 SB1 13354345 13354388 13354221
CMP63M /BK 6000 12.06 100 4 SB1 13354361 13421603 13354337
CMP63L /BK 3000 8.76 75 1.5 SB1 13354345 13354388 13354221
CMP63L /BK 3000 8.76 100 2.5 SB1 13354353 13354396 13354248
CMP63L /BK 4500 12.01 55 1.5 SB1 13354345 13354388 13354221
CMP63L /BK 4500 12.01 100 4 SB1 13354361 13421603 13354337
CMP71S /BP 3000 8.7 75 1.5 SB1 13354345 13354388 13354221
CMP71S /BP 3000 8.7 80 2.5 SB1 13354353 13354396 13354248
CMP71S /BP 4500 12.8 80 2.5 SB1 13354353 13354396 13354248
CMP71S /BP 4500 12.8 80 4 SB1 13354361 13421603 13354337
CMP71S /BP 6000 17 80 4 SB1 13354361 13421603 13354337
CMP71M /BP 3000 13.1 80 2.5 SB1 13354353 13354396 13354248
CMP71M /BP 3000 13.1 80 4 SB1 13354361 13421603 13354337
CMP71M /BP 4500 19.2 80 4 SB1 13354361 13421603 13354337
CMP71L /BP 3000 16.8 80 4 SB1 13354361 13421603 13354337
CMP80S /BP 3000 17.7 55 4 SB1 13354361 13421603 13354337
CMP80S /BP 4500 27 85 6 SBB 13350196 13350234 13350099
19381212/EN – 03/2015

CMP80M /BP 3000 23.5 85 6 SBB 13350196 13350234 13350099


CMP80M /BP 4500 35 80 6 SBB 13350196 13350234 13350099
CMP80M /BP 4500 35 85 10 SBB 13350218 13350242 13350102
CMP80L /BP 3000 32.5 85 6 SBB 13350196 13350234 13350099
CMP80L /BP 3000 32.5 85 10 SBB 13350218 13350242 13350102
CMP100S /BP 3000 34.2 70 6 SBB 13350196 13350234 13350099
CMP100S /BP 3000 34.2 70 10 SBB 13350218 13350242 13350102

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 363


12 Prefabricated cables
Cable assignment: CMP /BP /BK, 230 V system voltage

Motor Rated Standstill To cable Core Plug con- Cable part no.
speed current I0 length cross sec- nector Fixed Cable carrier Cable carrier ex-
tion routing installation tension1)
rpm A m mm2 Brakemotor
CMP100M /BP 3000 40 70 10 SBB 13350218 13350242 13350102
1) Currently only cable carrier extension cables are offered

19381212/EN – 03/2015

364 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Cable assignment: CMP /BP /VR, 230 V system voltage 12
12.14 Cable assignment: CMP /BP /VR, 230 V system voltage
The part numbers refer to the smallest connector that can be used:
• 1.5 mm2 to 4 mm2: SB1
• 6 mm2 to 16 mm2: SBB
Motor Rated Standstill To cable Core cross Plug con- Cable part no.
speed current I0 length section nector Fixed Cable carrier Cable carrier
routing installation extension1)
rpm A m mm2 Brakemotor
CMP71S /BP /VR 3000 11.8 55 1.5 SB1 13354345 13354388 13354221
CMP71S /BP /VR 3000 11.8 80 4 SB1 13354361 13421603 13354337
CMP71S /BP /VR 4500 17.4 80 4 SB1 13354361 13421603 13354337
CMP71S /BP /VR 6000 23 80 4 SB1 13354361 13421603 13354337
CMP71M /BP /VR 3000 19.1 80 4 SB1 13354361 13421603 13354337
CMP80S /BP /VR 3000 24.5 85 6 SBB 13350196 13350234 13350099
CMP80S /BP /VR 4500 37 75 6 SBB 13350196 13350234 13350099
12
CMP80S /BP /VR 4500 37 85 10 SBB 13350218 13350242 13350102
CMP80M /BP /VR 3000 34 80 6 SBB 13350196 13350234 13350099
CMP80M /BP /VR 3000 34 85 10 SBB 13350218 13350242 13350102
1) Currently only cable carrier extension cables are offered
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 365


12 Prefabricated cables
Cable assignment: CMPZ /BY, 230 V system voltage

12.15 Cable assignment: CMPZ /BY, 230 V system voltage


The following table allows for selecting power cables for CMP servo brakemotors with
a system voltage of 400 V and a BY brake with 400 V, 230 V or 110 V brake voltage.
An additional length for 110 V is specified in parenthesis for cases where the permit-
ted cable length for 110 V is shorter than for 400 V/230 V.
The part numbers refer to the smallest connector that can be used:
• 1.5 mm2 to 4 mm2: SB1
• 6 mm2 to 16 mm2: SBB
Motor Rated speed Standstill To cable Core Plug con- Cable part no.
current I0 length cross sec- nector Fixed Cable carrier in- Cable carrier ex-
tion routing stallation tension1)
rpm A m mm2 Brakemotor
CMPZ71S /BY 3000 8.7 80 1.5 SB1 13354272 13354302 13354221
CMPZ71S /BY 3000 8.7 100 2.5 SB1 13354280 13354310 13354248
CMPZ71S /BY 4500 12.8 90 2.5 SB1 13354280 13354310 13354248
CMPZ71S /BY 4500 12.8 100 4 SB1 13354299 13354329 13354337
CMPZ71S /BY 6000 17 100 4 SB1 13354299 13354329 13354337
CMPZ71M /BY 3000 13.1 100 4 SB1 13354299 13354329 13354337
CMPZ71M /BY 4500 19.2 98 4 SB1 13354299 13354329 13354337
CMPZ71L /BY 3000 16.8 100 4 SB1 13354299 13354329 13354337
CMPZ80S /BY 3000 17.7 65 2.5 SB1 13354280 13354310 13354248
CMPZ80S /BY 3000 17.7 100 4 SB1 13354299 13354329 13354337
CMPZ80S /BY 4500 27 100 6 SBB 13350129 13350153 13350099
CMPZ80S /BY 6000 35.5 78 6 SBB 13350129 13350153 13350099
CMPZ80S /BY 6000 35.5 100 10 SBB 13350137 13350161 13350102
CMPZ80M /BY 3000 23.5 100 6 SBB 13350129 13350153 13350099
CMPZ80M /BY 4500 35 80 6 SBB 13350129 13350153 13350099
CMPZ80M /BY 4500 35 100 10 SBB 13350137 13350161 13350102
CMPZ80M /BY 6000 46.9 100 10 SBB 13350137 13350161 13350102
CMPZ80L /BY 3000 32.5 86 6 SBB 13350129 13350153 13350099
CMPZ80L /BY 3000 32.5 100 10 SBB 13350137 13350161 13350102
CMPZ100S /BY 3000 34.2 82 6 SBB 13350129 13350153 13350099
CMPZ100S /BY 3000 34.2 100 10 SBB 13350137 13350161 13350102
CMPZ100M /BY 3000 40 100 10 SBB 13350137 13350161 13350102
1) Currently only cable carrier extension cables are offered

Permitted cable lengths for DC 24 V BY working brakes are especially reduced. Note
the following guidelines:
CMPZ71 . /BY: maximum 8 m
CMPZ80 . /BY: between 6.4 and 9 m depending on the cable cross section
CMPZ100 . /BY: between 4.5 and 7 m depending on the cable cross section
For project planning with DC 24 V BY working brake, consult SEW‑EURODRIVE.
19381212/EN – 03/2015

366 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Cable assignment: CMPZ /BY /VR, 230 V system voltage 12
12.16 Cable assignment: CMPZ /BY /VR, 230 V system voltage
The following table allows for selecting power cables for CMP servo brakemotors with
a system voltage of 400 V and a BY brake with 400 V, 230 V or 110 V brake voltage.
An additional length for 110 V is specified in parenthesis for cases where the permit-
ted cable length for 110 V is shorter than for 400 V/230 V.
The part numbers refer to the smallest connector that can be used:
• 1.5 mm2 to 4 mm2: SB1
• 6 mm2 to 16 mm2: SBB
Motor Rated Standstill To cable Core Plug con- Cable part no.
speed current I0 length cross sec- nector Fixed Cable carrier Cable carrier
tion routing installation extension1)
rpm A m mm2 Brakemotor
CMPZ71S /BY /VR 3000 11.8 59 1.5 SB1 13354272 13354302 13354221
CMPZ71S /BY /VR 3000 11.8 100 2.5 SB1 13354280 13354310 13354248
CMPZ71S /BY /VR 4500 17.4 100 4 SB1 13354299 13354329 13354337 12
CMPZ71S /BY /VR 6000 23 80 4 SB1 13354299 13354329 13354337
CMPZ71M /BY /VR 3000 19.1 98 4 SB1 13354299 13354329 13354337
CMPZ71M /BY /VR 4500 28 100 6 SBB 13350129 13350153 13350099
CMPZ71L /BY /VR 3000 27 100 6 SBB 13350129 13350153 13350099
CMPZ80S /BY /VR 3000 24.5 100 6 SBB 13350129 13350153 13350099
CMPZ80S /BY /VR 4500 37 76 6 SBB 13350129 13350153 13350099
CMPZ80S /BY /VR 4500 37 100 10 SBB 13350137 13350161 13350102
CMPZ80S /BY /VR 6000 48.5 97 10 SBB 13350137 13350161 13350102
CMPZ80S /BY /VR 6000 48.5 100 16 SBB 13350145 13350188 13350110
CMPZ80M /BY /VR 3000 34 83 6 SBB 13350129 13350153 13350099
CMPZ80M /BY /VR 3000 34 100 10 SBB 13350137 13350161 13350102
1) Currently only cable carrier extension cables are offered

Permitted cable lengths for DC 24 V BY working brakes are especially reduced. Note
the following guidelines:
CMPZ71 . /BY: maximum 8 m
CMPZ80 . /BY: between 6.4 and 9 m depending on the cable cross section
CMPZ100 . /BY: between 4.5 and 7 m depending on the cable cross section
For project planning with DC 24 V BY working brake, consult SEW‑EURODRIVE.
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 367


12 Prefabricated cables
Encoder cable assignment: Plug connector connection option /KKS

12.17 Encoder cable assignment: Plug connector connection option /KKS


Encoder Connection to Cable part number
® ®
MOVIDRIVE MOVIAXIS Fixed in- Cable carrier Fixed exten- Cable carrier
stallation installation sion extension
RH1M X15 01994875 01993194 01995421 01995413
X13 13327429 13327437
AS1H, ES1H X15 X13 13324535 13324551 01995391 01995405
AK1H, EK1H
AK0H, EK0H

12.18 Encoder cable assignment: Connection option KK


Encoder Connection to Cable part number
® ®
MOVIDRIVE MOVIAXIS Fixed installation Cable carrier installa-
tion
RH1M X15 13356259 13356267
X13 13356356 13356364
AK1H, EK1H
X15 X13 13356291 13356305
AK0H

12.19 Forced cooling fan cables


Cable type Cable cross section Part number
2
Fixed installation Forced cooling fan ca- 3 x 1 mm 01986341
Cable carrier installation ble 3 x 1 mm2 0199560X

19381212/EN – 03/2015

368 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Structure of prefabricated cables for CMP. servomotors 12
12.20 Structure of prefabricated cables for CMP. servomotors
12.20.1 Motor cables/brakemotor cables for CMP. servomotors
[5]
[1]
[2] [6]

500 ±5
[3]

[4]

12
4818640779

[1] Connector: Intercontec BSTA 078


[2] SEW‑EURODRIVE logo printed on cable
[3] Nameplate
[4] Line length ≤ 10 m: Tolerance +200 mm
Line length ≥ 10 m: Tolerance +2 %
Permitted line length according to the technical documents
[5] Prefabricated cable end for inverter
Required loose parts are supplied with the cable
[6] Shielding approx. 20 mm, pulled back approximately + 5 mm

Prefabrication motor side


The power cables on the motor side consist of an 8-pin plug connector and socket
contacts.
The shield is connected in the connector housing according to EMC requirements. All
plug connectors seal the connector on the cable end with a lamellar seal and ensure
cable relief according to EN 61884.

Prefabrication on inverter end


The individual cable cores of the motor and brakemotor cables are exposed and the
shield is prepared for connection in the control cabinet. The cable for the inverter end
still has to be prefabricated. The loose parts required are supplied with the cable in a
separate bag.
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 369


12 Prefabricated cables
Structure of prefabricated cables for CMP. servomotors

Loose parts
The following loose parts are supplied in accordance with the core cross sections for
connection to the power terminals on the inverter:

Bag no. Contents


1 4 x conductor end sleeves 1.5 mm2, insulated
4 x M6 U-shaped cable lugs 1.5 mm2
2 4 x conductor end sleeves 2.5 mm2, insulated
4 x M6 U-shaped cable lugs 2.5 mm2
3 4 x conductor end sleeves 4 mm2, insulated
4 x M6 U-shaped cable lugs 4 mm2

12.20.2 Feedback cable


[1]
[2] [5]

[3] Y

[4]

4818646539

[1] Connector: Intercontec ASTA


[2] Printed on connector: SEW‑EURODRIVE
[3] Nameplate
[4] Line length ≤ 10 m: Tolerance +200 mm
Cable length > 10 m: Tolerance +2%
Permitted line length according to the technical documents.
[5] D‑sub connector

Prefabrication motor end


A 12‑pin EMC signal plug connector from Intercontec with socket contacts is used on
the motor end for RH1M, AS1H, ES1H, AK0H, EK0H, AK1H, EK1H. The shield is con-
nected in the connector housing according to EMC requirements. All plug connectors
seal the plug on the cable end with a lamellar seal.
19381212/EN – 03/2015

370 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Structure of prefabricated cables for CMP. servomotors 12
Prefabrication on inverter end
A commercial D-sub EMC connector with pin contacts is used on the inverter end. A
9-pin or 15-pin connector matching the inverter is used.

Hybrid cable
The outer cable sheath on the motor and inverter end bears a nameplate with part
number and logo of the prefabricated cable manufacturer. The ordered length and per-
mitted tolerance are interrelated as follows:
• Cable length ≤ 10 m: Tolerance 200 mm.
• Cable length >10 m: Tolerance + 2%.

INFORMATION
Refer to the system manual of the inverter for determining the maximum cable length.
Make sure that an EMC-compliant environment is maintained during project planning. 12
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 371


12 Prefabricated cables
Power cables

12.21 Power cables


12.21.1 Motor cables

CMP motor cables

4818831115

CMP motor cable types

Type Number of cores Part number Routing


and cable cross
section
SM11 4 × 1.5 mm2 05904544 Fixed installation
2
SM11 4 × 1.5 mm 05906245 Cable carrier installation
2
SM12 4 × 2.5 mm 05904552 Fixed installation
SM12 4 × 2.5 mm2 05906253 Cable carrier installation
2
SM14 4 × 4 mm 05904560 Fixed installation
SM14 4 × 4 mm2 05904803 Cable carrier installation
2
SMB6 4 × 6 mm 13350269 Fixed installation
SMB6 4 × 6 mm2 13350293 Cable carrier installation
2
SMB10 4 × 10 mm 13350277 Fixed installation
SMB10 4 × 10 mm2 13350307 Cable carrier installation
2
SMB16 4 × 16 mm 13350285 Fixed installation
2
SMB16 4 × 16 mm 13350315 Cable carrier installation
SMC16 4 × 16 mm2 18148476 Fixed installation
2
SMC16 4 × 16 mm 18148484 Cable carrier installation
SMC25 4 × 25 mm2 18148581 Cable carrier installation
2
SMC35 4 × 35 mm 18148697 Cable carrier installation
19381212/EN – 03/2015

372 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Power cables 12
Pin assignment of the CMP motor cable

Plug connector view Pin Cable core color Assigned Extra


X
BSTA 078 1 (BK) Black U Bag of loose
parts
SM1 2 (GN/YE) Green/ PE
W1 Yellow

PE
3 D
3 (BK) Black W
C
4
2
4 (BK) Black V
V1 B

1 A
U1

Plug connector view Pin Cable core color Assigned Extra


X 12
CSTA 264 U (BK, WH) Black U Bag of loose
parts
SMB V with white lettering V
U, V, W
W W
V

V
- + PE (GN/YE) Green, yel- PE
W U low
U
1
W
2
PE

Plug connector view Pin Cable core color Assigned Extra


X
DSTA 001 U (BK, WH) Black U Bag of loose
parts
SMC V with white lettering V
U, V, W
W W
V
- + PE (GN/YE) Green, yel- PE
V
W U low
U
2
1

8837045259
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 373


12 Prefabricated cables
Power cables

CMP motor extension cable

X Y
4818839179

CMP motor extension cable types

Type Number of cores Part number Routing


and cable cross
section
SM11 4 × 1.5 mm2 13332457 Cable carrier installation
2
SM12 4 × 2.5 mm 13332465 Cable carrier installation
SM14 4 × 4 mm2 13332473 Cable carrier installation
2
SMB6 4 × 6 mm 13350021 Cable carrier installation
SMB10 4 × 10 mm2 13350048 Cable carrier installation
2
SMB16 4 × 16 mm 13350056 Cable carrier installation
2
SMC16 4 × 16 mm 18156819 Cable carrier installation
SMC25 4 x 25 mm2 18156827 Cable carrier installation
2
SMC35 4 x 35 mm 18156835 Cable carrier installation

19381212/EN – 03/2015

374 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Power cables 12
12.21.2 Brakemotor cable for BP/BK brakes

CMP brakemotor cable

500 ±
5
9007204073605387

Types of CMP brakemotor cables 12


Type Number of cores and Part num- Routing
cable cross section ber
SB11 4 × 1.5 mm2 + 3 × 1 mm2 13354345 Fixed installation
SB11 4 × 1.5 mm2 + 3 × 1 mm2 13354388 Cable carrier installation
2 2
SB12 4 × 2.5 mm + 3 × 1 mm 13354353 Fixed installation
2 2
SB12 4 × 2.5 mm + 3 × 1 mm 13354396 Cable carrier installation
SB14 4 × 4 mm2 + 3 × 1 mm2 13354361 Fixed installation
2 2
SB14 4 × 4 mm + 3 × 1 mm 13421603 Cable carrier installation
SBB6 4 × 6 mm2 + 3 × 1.5 mm2 13350196 Fixed installation
2 2
SBB6 4 × 6 mm + 3 × 1.5 mm 13350234 Cable carrier installation
SBB10 4 × 10 mm2 + 3 × 1.5 mm2 13350218 Fixed installation
2 2
SBB10 4 × 10 mm + 3 × 1.5 mm 13350242 Cable carrier installation
SBB16 4 × 16 mm2 + 3 × 1.5 mm2 13350226 Fixed installation
2 2
SBB16 4 × 16 mm + 3 × 1.5 mm 13350250 Cable carrier installation

INFORMATION
As only two signal lines are required for power cables for brakemotors with BP/BK
brake, the third signal wire is cut off when prefabricating the cable.
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 375


12 Prefabricated cables
Power cables

Pin assignment of CMP brakemotor cables

Plug connector view Pin Cable core color Assigned Extra


X
BSTA 078 1 (BK/WH) Black with U
white lettering
SB1 4 V
U, V, W
W1 BK/WH
3 W
D
BK/WH
PE 3

2 4
C 2 (GN/YE) Green/ PE
yellow Bag of
V1 B
1 A A – n. c. loose parts
U1 BK/WH

B – n. c.
C (BK/WH) Black with +
white lettering
D –
1, 2, 3

Plug connector view Pin Cable core color Assigned Extra


X
CSTA 264 U (BK/WH) Black with U
white lettering U, V,
SBB V V
W
BK/WH
V
BK/WH
W W
- +
V
W U
PE (GN/YE) Green/ PE
U
1 yellow Bag of
W BK
2
PE – (BK/WH) Black with – loose parts
white lettering
+ +
1, 2, 3
1 – n. c.
2 – n. c.

19381212/EN – 03/2015

376 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Power cables 12
12.21.3 Brakemotor cables BY brake

CMP brakemotor cable

500 ±
5
9007204073605387

CMP brakemotor cable types 12


Type Number of cores and ca- Part num- Routing
ble cross section ber
SB11 4 × 1.5 mm2 + 3 × 1 mm2 13354272 Fixed installation
SB11 4 × 1.5 mm2 + 3 × 1 mm2 13354302 Cable carrier installation
2 2
SB12 4 × 2.5 mm + 3 × 1 mm 13354280 Fixed installation
2 2
SB12 4 × 2.5 mm + 3 × 1 mm 13354310 Cable carrier installation
SB14 4 × 4 mm2 + 3 × 1 mm2 13354299 Fixed installation
2 2
SB14 4 × 4 mm + 3 × 1 mm 13354329 Cable carrier installation
SBB6 4 × 6 mm2 + 3 × 1.5 mm2 13350129 Fixed installation
2 2
SBB6 4 × 6 mm + 3 × 1.5 mm 13350153 Cable carrier installation
SBB10 4 × 10 mm2 + 3 × 1.5 mm2 13350137 Fixed installation
2 2
SBB10 4 × 10 mm + 3 × 1.5 mm 13350161 Cable carrier installation
SBB16 4 × 16 mm2 + 3 × 1.5 mm2 13350145 Fixed installation
2 2
SBB16 4 × 16 mm + 3 × 1.5 mm 13350188 Cable carrier installation
2 2
SBC16 4 × 16 mm + 3 × 1.5 mm 18148514 Fixed installation
SBC16 4 × 16 mm2 + 3 × 1.5 mm2 18148522 Cable carrier installation
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 377


12 Prefabricated cables
Power cables

Pin assignment of CMP brakemotor cables

Plug connector view Pin Cable core color Assigned Extra


X
BSTA 078 1 (BK/WH) Black with U
white lettering U, V,
SB1 4 V
W
W1 BK/WH
3 W
D
BK/WH
PE 3
C 2 (GN/YE) Green/ PE
2 4
Yellow Bag of
V1 B loose parts
U1
1 A
BK/WH A – n. c.
B (BK/WH) Black with 2
white lettering
C 1
D 3

Plug connector view Pin Cable core color Assigned Extra


X
CSTA 264 U (BK/WH) Black with U
white lettering U, V,
SBB V V
W
BK/WH
V
BK/WH
W W
- +
V
W U
PE (GN/YE) Green/ PE
1
U
yellow Bag of
W 2
BK loose parts
PE – (BK/WH) Black with 15
white lettering
+ 13
1 14
2 – n.c.

Plug connector view Pin Cable core color Assigned Extra


X
DSTA 001 U (BK/WH) Black with U
white lettering U, V,
SBC V V
W
BK (3)
V
BK (1) W W
- +
U
V PE (GN/YE) Green/ PE
Bag of
W
BK (2)
2
U yellow
1 loose parts
W – (BK/WH) Black with 15
white lettering
+ 13
1 14
2 – n.c.
19381212/EN – 03/2015

378 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Power cables 12
12.21.4 Extension cables BP/BK and BY brakes

CMP brakemotor extension cable

X Y
4818839179

CMP brakemotor extension cable types

Type Number of cores and ca- Part num- Routing


ble cross section ber
SB11 4 × 1.5 mm2 + 3 × 1 mm2 13354221 Cable carrier installation
2 2
SB12 4 × 2.5 mm + 3 × 1 mm 13354248 Cable carrier installation
SB14 4 × 4 mm2 + 3 × 1 mm2 13354337 Cable carrier installation 12
SBB6 4 × 6 mm2 + 3 × 1.5 mm2 13350099 Cable carrier installation
SBB10 4 × 10 mm2 + 3 × 1.5 mm2 13350102 Cable carrier installation
2 2
SBB16 4 × 16 mm + 3 × 1.5 mm 13350110 Cable carrier installation
SBC16 4 × 16 mm2 + 3 × 1.5 mm2 18156843 Cable carrier installation
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 379


12 Prefabricated cables
Encoder cables

12.22 Encoder cables


12.22.1 Resolver

Resolver cable RH1M for MOVIDRIVE® MDX60B/61B

X
Y

4819177867

Resolver cable types RH1M for MOVIDRIVE® MDX60B/61B

Type Number of cores and cable Part number Routing


cross section
CMP 5 × 2 × 0.25 mm2 01994875 Fixed installation
2
CMP 5 × 2 × 0.25 mm 01993194 Cable carrier installation

Resolver cable RH1M for MOVIAXIS® MX

X
Y

4819185931

Resolver cable types RH1M for MOVIAXIS® MX

Type Number of cores and cable Part number Routing


cross section
CMP 5 × 2 × 0.25 mm2 13327429 Fixed installation
2
CMP 5 × 2 × 0.25 mm 13327437 Cable carrier installation
19381212/EN – 03/2015

380 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Encoder cables 12
Extension cable for RH1M resolver

X Y
4819192715

Extension cable types for RH1M resolvers

Type Number of cores and cable Part number Routing


cross section
CMP 5 × 2 × 0.25 mm2 01995421 Fixed installation
2
CMP 5 × 2 × 0.25 mm 01995413 Cable carrier installation

Alternative plug connector for RH1M resolver cables 12


Signal plug connector with socket contacts (complete)

Type Cross sections that can be Part number


connected
RH1M 6 x 2 x 0.06 to 1 mm2 01986732

Resolver cable, terminal box CMP for MOVIDRIVE®

4838463371

Resolver cables types, terminal box CMP for MOVIDRIVE

Type Number of cores Part number Routing


and cross sections
CMP 5 × 2 × 0.25 mm2 13356259 Fixed installation
CMP 13356267 Cable carrier installation
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 381


12 Prefabricated cables
Encoder cables

Pin assignment of resolver cables – terminal box for RH1M

Resolver cables, terminal box connection RH1M resolver for CMP motors
Motor connection end Connection –
MOVIDRIVE® MDX..B
Terminal strip Pin no. Description Cable core color Description Pin no. Plug
connec-
tor
1 R1 (reference Pink (PK) R1 (reference 3 D‑sub,
1

+) +) 9‑pole
2
3

2 R2 (reference Gray (GY) R2 (reference 8


4

-) -)
5

1
6
6

3 S1 (cosine +) Red (RD) S1 (cosine +) 2


7
8

4 S3 (cosine -) Blue (BU) S3 (cosine -) 7 9 5


9
12 11 10

5 S2 (sine +) Yellow (YE) S2 (sine +) 1 View Y


6 S4 (sine -) Green (GN) S4 (sine -) 6
12642818315
7 n.c. – n.c. 4
View X
8 n.c. – – –
9 TF/KTY + (BN) Brown / (VT) TF/ KTY + 9
violet1)
10 TF/KTY - (WH) White / (BK) TF/ KTY - 5
Black2)
11 n.c. n.c. n.c. –
12 n.c. n.c. n.c. –
1) Double assignment to increase cross section
2) Double assignment to increase cross section

Resolver cable terminal box CMP for MOVIAXIS®

4838463371

Resolver cable types terminal box CMP for MOVIAXIS®

Type Number of cores Part number Routing


19381212/EN – 03/2015

and cross sections


CMP 5 × 2 × 0.25 mm2 13356356 Fixed installation
CMP 13356364 Cable carrier installation

382 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Encoder cables 12
RH1M resolver cables terminal box – pin assignment

Resolver cables, terminal box connection RH1M resolver for CMP motors
Motor connection end Connection –
MOVIAXIS® MXA
Terminal strip Pin no. Description Cable core color Description Pin no. Plug
connec-
tor
1 R1 (reference Pink (PK) R1 (reference 5 D‑sub,
1

+) +) 9‑pole
2
3

2 R2 (reference Gray (GY) R2 (reference 13


4

-) -)
5

1
6
6

3 S1 (cosine +) Red (RD) S1 (cosine +) 2


7
8

4 S3 (cosine -) Blue (BU) S3 (cosine -) 10 9 5


12
9
12 11 10

5 S2 (sine +) Yellow (YE) S2 (sine +) 1 View Y


6 S4 (sine -) Green (GN) S4 (sine -) 9
12642818315
7 n.c. – n.c. 4
View X
8 n.c. – – –
9 TF/KTY + (BN) Brown / (VT) TF/ KTY + 14
violet1)
10 TF/KTY - (WH) White / (BK) TF/ KTY - 6
Black2)
11 n.c. n.c. n.c. –
12 n.c. n.c. n.c. –
1) Double assignment to increase cross section
2) Double assignment to increase cross section
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 383


12 Prefabricated cables
Encoder cables

12.22.2 Hiperface® encoders

Hiperface® encoder cable for MOVIDRIVE® B and MOVIAXIS® MX

X
Y

4819185931

Hiperface® encoder cable types for MOVIDRIVE® B and MOVIAXIS MX

Type Number of cores and cable Part number Routing


cross section
CMP 6 × 2 × 0.25 mm2 13324535 Fixed installation
2
CMP 6 × 2 × 0.25 mm 13324551 Cable carrier installation

Extension cable for Hiperface® encoders AK0H / EK0H / AS1H / ES1H / AK1H / EK1H

X Y

4819207051

Extension cable types for Hiperface® encoders K0H / EK0H / AS1H / ES1H / AK1H / EK1H

Type Number of cores and cable Part number Routing


cross section
CMP 6 × 2 × 0.25 mm2 01995391 Fixed installation
CMP 6 × 2 × 0.25 mm2 01995405 Cable carrier installation

Alternative plug connector cables for Hiperface® encoders AK0H / EK0H / AS1H / ES1H / AK1H /
EK1H
Signal plug connector with socket contacts (complete)

Type Cross sections that can be con- Part number


nected
AK0H 6 x 2 x 0.06 to 1 mm2 01986732
EK0H
AS1H
ES1H
AK1H
19381212/EN – 03/2015

EK1H

384 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Encoder cables 12
Hiperface® encoder cable, terminal box, CMP for MOVIAXIS®, MOVIDRIVE

4838486411

Hiperface® encoder cable types, terminal box, CMP for MOVIAXIS®, MOVIDRIVE®

Type Number of cores Part number Routing


and cable cross sec-
tion
CMP 5 × 2 × 0.25 mm2 13356291 Fixed installation
12
CMP 13356305 Cable carrier installation

Pin assignment for Hiperface® encoder cables, terminal box, AS1H / ES1H / AK1H / AK0H / EK1H

Hiperface® cable, terminal box connection MOVIAXIS® MXA, MOVIDRIVE® MDX..B with CMP motors
Motor connection end Connection
MOVIAXIS® MXA
MOVIDRIVE
®
MDX..B
Terminal strip Pin no. Description Cable core color Description Pin no. Plug
connec-
tor
6 Data + Black (BK) Data + 4 D-sub,
1

15-pin
2

5 Data - Violet (VT) Data - 12


3
4

1 S1 (COS +) Red (RD) S1 (COS +) 1


5

1
9
6

2 S3 (COS -) Blue (BU) S3 (COS -) 9


7

3 S2 (SIN +) Yellow (YE) S2 (SIN +) 2


8

15 8
9

4 S4 (SIN -) Green (GN) S4 (SIN -) 10


12 11 10

7 GND Gray-pink (GYPK) / GND 8 View Y


12642818315 pink (PK)
View X 8 Us Red blue (RDBU) Us 15
9 TF / TH / KTY Brown (BN) TF / TH / KTY 14
+ +
10 TF / TH / KTY White (WH) TF / TH / KTY 6
- -
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 385


12 Prefabricated cables
Forced cooling fan cables

12.23 Forced cooling fan cables


12.23.1 Cable for motors with forced cooling fan VR
[1] [3] [2] [3]

[4]

4819487627

[1] Connector: STAK 200


[2] Printed on connector: SEW-EURODRIVE
[3] Nameplate
[4] Line length ≤ 5 m: Tolerance +200 mm
Line length ≥ 5 m: Tolerance +2%
Permitted line length according to the technical documents.

12.23.2 Cable types for motors with forced cooling fan VR

Type Cross section Routing Part number


CMP 3 × 1 mm2 (AWG 18) Fixed installation 01986341
CMP Cable carrier installa- 0199560X
tion

12.23.3 Pin assignment of cables for motors with VR forced cooling fan

STAK 200 plug Con- Core iden- As- Pin Connection


connector view X tact tification signed type
Connector with 1 Digit 1 24 V + Cut-off, length Conductor
two socket con- approx. 250 mm end sleeves
2 Digit 2 0V
tacts
19381212/EN – 03/2015

386 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Forced cooling fan cables 12
12.23.4 Alternative connector for VR forced cooling fan cable
Signal plug connector with socket contacts (complete)

Type Cross sections that can be Routing Part number


connected
VR 3 x 1 mm2 (AWG 18) Fixed installation / cable 01984985
carrier installation

12.23.5 Extension cable for motors with forced cooling fan VR


[1] [3] [2] [3] [5]

X Y
12
[4]

4819495051

[1] Connector: STAS 200


[2] Printed on connector: SEW-EURODRIVE
[3] Nameplate
[4] Line length ≤ 5 m: Tolerance +200 mm
Line length ≥ 5 m: Tolerance +2%
Permitted line length according to the technical documents.
[5] Socket: STAK 200

12.23.6 Extension cable types for motors with forced cooling fan VR

Type Cross section Routing Part number


2
CMP 3 × 1 mm (AWG 18) Fixed installation 01995618
CMP Cable carrier installa- 01995626
tion

12.23.7 Alternative connector for cable for the VR forced cooling fan
Signal plug connector with pins (complete)

Type Cross sections that can be con- Part no.


nected
VR 3 x 1 mm2 01985693
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 387


12 Prefabricated cables
Cable specifications of power cables

12.24 Cable specifications of power cables


12.24.1 Fixed installation

Motor cables
Routing Fixed
Cable cross sections 4 x 1.5 4 x 2.5 4x4 4x6 4 x 10 4 x 16
mm2 mm2 mm2 mm2 mm2 mm2
(AWG 16) (AWG 14) (AWG 12) (AWG 10) (AWG 8) (AWG 5)
Manufacturer HELUKABEL
Manufacturer designation LI9YCY
Operating voltage V 600 / 1000
V0 / V AC
Temperature range °C Fixed installation – 40 to +80
Max. temperature °C +80
Min. bending radius mm 45 55 65 73 85 106.5
Diameter D mm 9.0 ± 0.2 11 ± 0.2 13 ± 0.2 14.3 ± 0.3 17.0 ± 0.6 21.3 ± 0.6
Core identification BK with lettering WH + GN/YE
Sheath color Orange, similar to RAL 2003
Approval(s) DESINA / VDE / UL
Capacitance conductor/ nF/km 110 110 118 125 125 130
shield
Capacitance core/core nF/km 70 70 75 80 80 85
Halogen-free No
Silicon-free Yes
CFC-free Yes
Inner insulation (conductor) PP
Outer insulation (sheath) PVC
Flame retardant/self-extinguishing Yes
Conductor material Cu
Shielding Tinned Cu
Weight (cable) kg/km 134 202 262 332 601 1040

19381212/EN – 03/2015

388 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Cable specifications of power cables 12
Brakemotor cables
Routing Fixed
Cable cross sections 4 x 1.5 4 x 2.5 4x4 4x6 4 x 10 4 x 16
mm2 mm2 mm2 mm2 mm2 mm2
(AWG 16) (AWG 14) (AWG 12) (AWG 10) (AWG 8) (AWG 5)
+ + + + + +
3x1 3x1 3x1 3 x 1.5 3 x 1.5 3 x 1.5
mm2 mm2 mm2 mm2 mm2 mm2
(AWG 18) (AWG 18) (AWG 18) (AWG 16) (AWG 16) (AWG 16)
Manufacturer HELUKABEL
Manufacturer designation LI9YCY
Operating voltage V 600 / 1000
V0 / V AC
Temperature range °C Fixed installation: – 40 to +80
Max. temperature °C +80
Min. bending radius mm 60 68 75 85 100 116
Diameter D mm 11.8 ± 0.4 13.4 ± 0.4 15.0 ± 0.5 17.0 ± 0.6 20.0 ± 1.0 23.2 ± 1.0
Core identification BK with lettering WH + GN/YE 12
Sheath color Orange similar to RAL 2003
Approval(s) DESINA / VDE / UL
Capacitance conductor/shield nF/km 105 105 110 115 120 130
Capacitance core/core nF/km 60 60 70 75 78 85
Halogen-free No
Silicon-free Yes
CFC-free Yes
Inner insulation (conductor) PP
Outer insulation (sheath) PVC
Flame retardant/self-extinguishing Yes
Conductor material Cu
Shielding Tinned Cu
Weight (cable) kg/km 229 292 393 542 938 1230
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 389


12 Prefabricated cables
Cable specifications of power cables

12.24.2 Cable carrier installation

Motor cables
Routing Cable carrier
Cable cross sections 4 x 1.5 mm2 4 x 2.5 mm2 4 x 4.0 mm2 4 x 6.0 mm2 4x 4x 4x 4x
10 mm2 16 mm2 25 mm2 35 mm2
(AWG 16) (AWG 14) (AWG 12) (AWG 10) (AWG 8) (AWG 5) (AWG 3) (AWG 2)
Manufacturer Nexans Helukabel
Manufacturer's designation PSL(LC)C11Y-J 4 x – PSL11YC11Y-J 4 x – mm2 TOPSERV 109
mm2
Operating voltage V 600 / 1000
V0 / V AC
Temperature range °C -20 to +60 -50 to +80 -50 to +80
Max. temperature °C +90 (on conductor)
Min. bending radius mm 134 140 135 155 180 225 191 215
Diameter D mm 12.8 + 0.6 / 15.7 ± 0.3 13.2 ± 0.4 15.4 ± 0.4 17.8 ± 0.5 21.8 ± 0.7 25.4 28.6
Maximum acceleration m/s2 20
Max. velocity m/min 200 at max. travel distance of 5 m
Core identification BK with lettering WH + GN/YE
Sheath color Orange similar to RAL 2003
Approval(s) DESINA / VDE / UL / cRUus
Capacitance conductor/ nF/km 95 95 170 170 170 – – –
shield
Capacitance core/core nF/km 65 65 95 95 95 – – –
Halogen-free Yes
Silicon-free Yes
CFC-free Yes
Inner insulation (conductor) Polyolefin TPM
Outer insulation (sheath) TPU (PUR)
Flame retardant/self-extinguishing Yes
Conductor material E-Cu blank
Shielding Braided tinned Cu shield (optically covered > 85%)
Weight (cable) kg/km 249 373 311 426 644 977 1523 2080
Min. bending cycles ≥ 5 million

19381212/EN – 03/2015

390 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Cable specifications of power cables 12
Brakemotor cables
Routing Cable carrier
Cable cross sections 4 x 1.5 mm2 4 x 2.5 mm2 4 x 4 mm2 4 x 6 mm2 4 x 10 mm2 4 x 16 mm2
(AWG 16) (AWG 14) (AWG 12) (AWG 10) (AWG 8) (AWG 5)
+ + + + + +
3 x 1 mm2 3 x 1 mm2 3 x 1 mm2 3 x 1,5 mm2 3 x 1,5 mm2 3 x 1,5 mm2
(AWG 18) (AWG 18) (AWG 18) (AWG 16) (AWG 16) (AWG 16)
Manufacturer Nexans
Manufacturer designation PSL(LC)C11Y-J 4x... +3A.../C PSL11YC11Y-J 4x... +3A.../C
Operating voltage V 600 / 1000
V0 / V AC
Temperature range °C -20 to +60
Max. temperature °C +90 (conductor)
Min. bending radius mm 159 170 155 175 200 235
Diameter D mm 15.0 ± 0.9 16.5 ± 0.7 15.3 ± 0.5 17.4 ± 0.5 20.5 ± 0.5 23.3 ± 0.7
Maximum acceleration m/s2 20
Max. velocity m/min 200 at max. travel distance of 5 m
Core identification BK with lettering WH + GN/YE 12
Sheath color Orange similar to RAL 2003
Approval(s) DESINA / VDE / UL / cRUus
Capacitance conductor/shield nF/km 105 105 170 170 170 170
Capacitance core/core nF/km 65 65 95 95 95 95
Halogen-free Yes
Silicon-free Yes
CFC-free Yes
Inner insulation (cable) TPM
Outer insulation (sheath) Polyolefin TPU (PUR)
Flame retardant/self-extinguishing Yes
Conductor material E-Cu blank
Shielding Braided tinned Cu shield (optically covered > 85%)
Weight (cable) kg/km 335 433 396 522 730 1053
Min. bending cycles ≥ 5 million
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 391


12 Prefabricated cables
Cable specification of encoder cables

12.25 Cable specification of encoder cables


12.25.1 Fixed installation of feedback cables
Accessory designation AS1H / ES1H /AK0H /EK0H / RH1M
AK1H /EK1H
Cable cross sections 6 x 2 x 0.25 mm2 5 x 2 x 0.25 mm2
Manufacturer HELUKABEL
Manufacturer designation LI9YCY
Operating voltage V0 / V AC V 230 / 350
Temperature range °C Fixed installation -40 to +80
Max. temperature °C + 80
Min. bending radius mm 43 36.5
Diameter D mm 8.6 ± 0.2 7.3 ± 0.2
Core identification DIN 47 100
Sheath color Green, similar to RAL 6018
Approval(s) DESINA / VDE / cRUus
Capacitance core/shielding nF/km 110
Capacitance core/core nF/km 70
Halogen-free No
Silicone-free Yes
CFC-free Yes
Inner insulation (conductor) PP
Outer insulation (sheath) PVC
Flame-retardant/self-extinguishing No
Conductor material Cu blank
Shielding Braided tinned Cu
Weight (cable) kg/km 107 78

19381212/EN – 03/2015

392 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Cable specification of encoder cables 12
12.25.2 Cable carrier installation of feedback cables
Accessory designation AS1H / ES1H /AK0H /EK0H / RH1M
AK1H /EK1H
Cable cross sections 6 x 2 x 0.25 mm2 5 x 2 x 0.25 mm2
Manufacturer Nexans
Manufacturer designation SSL18YC11Y 6 x 2 x 0.25/ SSL11YC11Y 5 x 2 x 0.25
Operating voltage V0 / V AC V 300
Temperature range °C -20 to + 60
Max. temperature °C +90 (on conductor)
Min. bending radius mm 100 80
Diameter D mm 9.8 ± 0.2 9.5 ± 0.2
Maximum acceleration m/s2 20
Max. velocity m/min 200
Core identification WH/BN, GN/YE, GY/PK, BU/RD, WH/BN, GN/YE, GY/PK,
BK/VT, GY-PK/RD-BU BU/RD, BK/VT
Sheath color Green similar to RAL 6018
Approval(s) DESINA / VDE / cRUus 12
Capacitance core/shielding nF/km 100
Capacitance core/core nF/km 55
Halogen-free Yes
Silicone-free Yes
CFC-free Yes
Inner insulation (conductor) PP
Outer insulation (sheath) TPE-U
Flame-retardant/self-extinguish- Yes
ing
Conductor material E-Cu blank
Shielding Braided tinned Cu
Weight kg/km 130 120
Min. bending cycles ≥ 5 million
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 393


12 Prefabricated cables
Cable specifications of forced cooling fan cables

12.26 Cable specifications of forced cooling fan cables


12.26.1 Fixed installation of forced cooling fan cables
Accessory designation VR
Cable cross sections 3 x 1 mm2
Manufacturer Lapp
Manufacturer's designation Ölflex 110 Classic
Operating voltage V0 / V AC V 300 / 500
Temperature range °C -30 to +70
Max. temperature °C + 70
Min. bending radius mm 24
Diameter D mm 6.0 ± 0.3
Core identification VDE 0293
Sheath color Silver gray, RAL 7001
Approval(s) VDE
Capacitance core/shielding nF/km –
Capacitance core/core nF/km –
Halogen-free No
Silicone-free Yes
CFC-free Yes
Inner insulation (conductor) PVC
Outer insulation (sheath) PVC
Flame-retardant/self-extinguishing No
Conductor material Cu blank
Shielding –
Weight (cable) kg/km 65

19381212/EN – 03/2015

394 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Prefabricated cables
Cable specifications of forced cooling fan cables 12
12.26.2 Cable carrier installation for forced cooling fan cables
Accessory designation VR
Cable cross sections 3 x 1 mm2
Manufacturer Nexans
Manufacturer designation PSL 3 x 1.0
Operating voltage V0 / V AC V 300
Temperature range °C - 30 to + 70
Max. temperature °C +90 (on conductor)
Min. bending radius mm 45
Diameter D mm 5.7 ± 0.2
Maximum acceleration m/s2 10
Max. velocity m/min 50
Core identification 2 x WH with digit
+ 1 x GN/YE
Sheath color Black RAL 9005
Approval(s) VDE / UL
Capacitance core/shielding nF/km – 12
Capacitance core/core nF/km –
Halogen-free Yes
Silicone-free Yes
CFC-free Yes
Inner insulation (conductor) TPM
Outer insulation (sheath) TPE-U
Flame-retardant/self-extinguishing Yes
Conductor material E-Cu blank
Shielding –
Weight kg/km 50
Min. bending cycles ≥ 5 million
19381212/EN – 03/2015

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 395


13 Appendix
Cable dimensions to AWG

13 Appendix
13.1 Cable dimensions to AWG
AWG stands for American Wire Gauge and refers to the size of wires. The number
specifies the diameter or cross section of a wire in code. This type of cable designa-
tion is usually only used in the USA. However, the designations can also be seen in
catalogs or data sheets in Europe.

AWG designation Cross section in


mm2
000000 (6/0) 185
00000 (5/0) 150
0000 (4/0) 120
000 (3/0) 90
00 (2/0) 70
0 (1/0) 50
1 50
2 35
3 25
4 25
5 16
6 16
7 10
8 10
9 6
10 6
11 4
12 4
13 2.5
14 2.5
15 2.5
16 1.5
16 1
18 1
19 0.75
20 0.5
19381212/EN – 03/2015

21 0.5
22 0.34
23 0.25
24 0.2

396 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Address Directory
14
14 Address Directory
Germany
Headquarters Bruchsal SEW-EURODRIVE GmbH & Co KG Tel. +49 7251 75-0
Production plant Ernst-Blickle-Strasse 42 Fax +49 7251 75-1970
Sales 76646 Bruchsal, Germany http://www.seweurodrive.com
P.O. box address [email protected]
Postfach 3023 • D-76642 Bruchsal, Germany
Production Plant / In- Bruchsal SEW-EURODRIVE GmbH & Co KG Tel. +49 7251 75-0
dustrial Gear Units Christian-Pähr-Str.10 Fax +49 7251 75-2970
76646 Bruchsal, Germany
Production plant Graben SEW-EURODRIVE GmbH & Co KG Tel. +49 7251 75-0
Ernst-Blickle-Strasse 1 Fax +49 7251 75-2970
76676 Graben-Neudorf, Germany
P.O. box address
Postfach 1220 • 76671 Graben-Neudorf, Germa-
ny
Östringen SEW-EURODRIVE GmbH & Co KG, Oestringen Tel. +49 7253 9254-0
Plant Fax +49 7253 9254-90
Franz-Gurk-Strasse 2 oestringen@sew‑eurodrive.de
76684 Oestringen, Germany
Service Competence Mechanical/ SEW-EURODRIVE GmbH & Co KG Tel. +49 7251 75-1710
Centers Mechatronic Ernst-Blickle-Strasse 1 Fax +49 7251 75-1711 14
Components 76676 Graben-Neudorf, Germany sc-mitte@sew‑eurodrive.de
Electronics SEW-EURODRIVE GmbH & Co KG Tel. +49 7251 75-1780
Ernst-Blickle-Strasse 42 Fax +49 7251 75-1769
76646 Bruchsal, Germany [email protected]
Drive Technology North SEW-EURODRIVE GmbH & Co KG Tel. +49 5137 8798-30
Center Alte Ricklinger Strasse 40-42 Fax +49 5137 8798-55
30823 Garbsen (near Hanover) [email protected]
East SEW-EURODRIVE GmbH & Co KG Tel. +49 3764 7606-0
Daenkritzer Weg 1 Fax +49 3764 7606-30
08393 Meerane (near Zwickau) sc-ost@sew‑eurodrive.de
South SEW-EURODRIVE GmbH & Co KG Tel. +49 89 909552-10
Domagkstrasse 5 Fax +49 89 909552-50
85551 Kirchheim (near Munich) sc-sued@sew‑eurodrive.de
West SEW-EURODRIVE GmbH & Co KG Tel. +49 2173 8507-30
Siemensstrasse 1 Fax +49 2173 8507-55
40764 Langenfeld (near Düsseldorf) sc-west@sew‑eurodrive.de
Drive Service Hotline/24-hour availability +49 800 SEWHELP
+49 800 7394357
Technical offices Augsburg SEW-EURODRIVE GmbH & Co KG Tel. +49 821 22779-10
August-Wessels-Strasse 27 Fax +49 821 22779-50
86156 Augsburg, Germany tb-augsburg@sew‑eurodrive.de
Berlin SEW-EURODRIVE GmbH & Co KG Tel. +49 306331131-30
Lilienthalstrasse 3a Fax +49 306331131-36
12529 Schoenefeld, Germany tb-berlin@sew‑eurodrive.de
Lake Constance SEW-EURODRIVE GmbH & Co KG Tel. +49 7544 96590-90
Dornierstraße 4 Fax +49 7544 96590-99
88677 Markdorf, Germany tb-bodensee@sew‑eurodrive.de
Bremen SEW-EURODRIVE GmbH & Co KG Tel. +49 421 33918-10
Bornstr.19 ... 22 Fax +49 421 33918-22
28195 Bremen, Germany tb-bremen@sew‑eurodrive.de
Dortmund SEW-EURODRIVE GmbH & Co KG Tel. +49 231 229028-10
Hildastraße 8 Fax +49 231 229028-20
44145 Dortmund, Germany tb-dortmund@sew‑eurodrive.de
Dresden SEW-EURODRIVE GmbH & Co KG Tel. +49 351 26338-0
19381212/EN – 03/2015

Hauptstrasse 32 Fax +49 351 26338-38


01445 Radebeul, Germany tb-dresden@sew‑eurodrive.de
Erfurt SEW-EURODRIVE GmbH & Co KG Tel. +49 361 21709-70
Dubliner Strasse 12 Fax +49 361 21709-79
99091 Erfurt, Germany tb-erfurt@sew‑eurodrive.de
Guestrow SEW-EURODRIVE GmbH & Co KG Tel. +49 3843 8557-80
Glasewitzer Chaussee 33 B Fax +49 3843 8557-88
18273 Guestrow, Germany tb-guestrow@sew‑eurodrive.de
P.O. box address
Postfach 1216 • 18262 Güstrow, Germany

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 397


14 Address Directory

Germany
Hamburg SEW-EURODRIVE GmbH & Co KG Tel. +49 40 298109-60
Bramfelder Strasse 119 Fax +49 40 298109-70
22305 Hamburg, Germany tb-hamburg@sew‑eurodrive.de
Hanover/Garbsen SEW-EURODRIVE GmbH & Co KG Tel. +49 5137 8798-10
Alte Ricklinger Str.40-42 Fax +49 5137 8798-50
30823 Garbsen, Germany tb-hannover@sew‑eurodrive.de
P.O. box address
Postfach 1104 53 • 30804 Garbsen, Germany
Heilbronn SEW-EURODRIVE GmbH & Co KG Tel. +49 7143 8738-0
Zeppelinstrasse 7 Fax +49 7143 8738-25
74357 Boennigheim, Germany tb-heilbronn@sew‑eurodrive.de
Herford SEW-EURODRIVE GmbH & Co KG Tel. +49 5221 9141-0
Göbenstraße 3 – 7 Fax +49 5221 9141-20
32052 Herford tb-herford@sew‑eurodrive.de
Karlsruhe SEW-EURODRIVE GmbH & Co KG Tel. +49 7245 9190-10
Ettlinger Weg 2 Fax +49 7245 9190-20
76467 Bietigheim, Germany tb-karlsruhe@sew‑eurodrive.de
P.O. box address
Postfach 43 • 76463 Bietigheim, Germany
Kassel SEW-EURODRIVE GmbH & Co KG Tel. +49 561 95144-80
Lange Strasse 14 Fax +49 561 95144-90
34253 Lohfelden, Germany tb-kassel@sew‑eurodrive.de
Koblenz SEW-EURODRIVE GmbH & Co KG Tel. +49 2652 9713-30
Bahnstrasse 17a Fax +49 2652 9713-40
56743 Mendig, Germany tb-koblenz@sew‑eurodrive.de
Lahr SEWEURODRIVE GmbH & Co KG Tel. +49 7821 90999-60
Europastrasse 3/1 Fax +49 7821 90999-79
77933 Lahr/Schwarzwald, Germany tb-lahr@sew‑eurodrive.de
Langenfeld SEW-EURODRIVE GmbH & Co KG Tel. +49 2173 8507-10
Siemensstrasse 1 Fax +49 2173 8507-50
40764 Langenfeld, Germany tb-langenfeld@sew‑eurodrive.de
Magdeburg SEW-EURODRIVE GmbH & Co KG Tel. +49 39203 7577-1
Breiteweg 53 Fax +49 39203 7577-9
39179 Barleben, Germany tb-magdeburg@sew‑eurodrive.de
Mannheim SEW-EURODRIVE GmbH & Co KG Tel. +49 621 71683-10
Besselstrasse 26 Fax +49 621 71683-22
68219 Mannheim, Germany tb-mannheim@sew‑eurodrive.de
Munich SEW-EURODRIVE GmbH & Co KG Tel. +49 89 90955-110
Domagkstrasse 5 Fax +49 89 90955-150
85551 Kirchheim, Germany tb-muenchen@sew‑eurodrive.de
Muenster SEW-EURODRIVE GmbH & Co KG Tel. +49 251 41475-11
Hafenplatz 4 Fax +49 251 41475-50
48155 Muenster, Germany tb-muenster@sew‑eurodrive.de
Nuremberg SEW-EURODRIVE GmbH & Co KG Tel. +49 911 98884-50
Plattenaeckerweg 6 Fax +49 911 98884-60
90455 Nuremberg, Germany tb-nuernberg@sew‑eurodrive.de
Regensburg SEW-EURODRIVE GmbH & Co KG Tel. +49 941 46668-68
Im Gewerbepark A15 Fax +49 941 46668-66
93059 Regensburg, Germany tb-regensburg@sew‑eurodrive.de
Rhine-Main SEW-EURODRIVE GmbH & Co KG Tel. +49 6172 9617-0
Niederstedter Weg 5 Fax +49 6172 9617-50
61348 Bad Homburg, Germany tb-rheinmain@sew‑eurodrive.de
Stuttgart SEW-EURODRIVE GmbH & Co KG Tel. +49 711 16072-0
Friedrich-List-Strasse 46 Fax +49 711 16072-72
70771 Leinfelden-Echterdingen, Germany tb-stuttgart@sew‑eurodrive.de
Ulm SEWEURODRIVE GmbH & Co KG Tel. +49 7348 9885-0
19381212/EN – 03/2015

Dieselstrasse 14 Fax +49 7348 9885-90


89160 Dornstadt, Germany tb-ulm@sew‑eurodrive.de
Drive Center SEW-EURODRIVE GmbH & Co KG Tel. +49 931 27886-60
Wuerzburg Nuernbergerstrasse 118 Fax +49 931 27886-66
97076 Wuerzburg-Lengfeld, Germany tb-wuerzburg@sew‑eurodrive.de
Zwickau / Meer- SEW-EURODRIVE GmbH & Co KG Tel. +49 3764 7606-0
ane Dänkritzer Weg 1 Fax +49 3764 7606-20
08393 Meerane, Germany tb-zwickau@sew‑eurodrive.de

398 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Address Directory
14
France
Production plant Haguenau SEW-USOCOME Tel. +33 3 88 73 67 00
Sales 48-54 route de Soufflenheim Fax +33 3 88 73 66 00
Service B. P. 20185 http://www.usocome.com
67506 Haguenau Cedex, France [email protected]
Production plant Forbach SEW-USOCOME Tel. +33 3 87 29 38 00
Zone industrielle
Technopôle Forbach Sud
B. P. 30269
57604 Forbach Cedex, France
Assembly plant Bordeaux SEW-USOCOME Tel. +33 5 57 26 39 00
Sales Parc d'activités de Magellan Fax +33 5 57 26 39 09
Service 62 avenue de Magellan - B. P. 182
33607 Pessac Cedex, France
Lyon SEW-USOCOME Tel. +33 4 72 15 37 00
Parc d'affaires Roosevelt Fax +33 4 72 15 37 15
Rue Jacques Tati
69120 Vaulx en Velin, France
Nantes SEW-USOCOME Tel. +33 2 40 78 42 00
Parc d’activités de la forêt Fax +33 2 40 78 42 20
4 rue des Fontenelles
44140 Le Bignon, France
Paris SEW-USOCOME Tel. +33 1 64 42 40 80
Zone industrielle Fax +33 1 64 42 40 88 14
2 rue Denis Papin
77390 Verneuil I'Etang, France
Technical offices Alsace SEW-USOCOME Tel. +33 3 89 74 51 62
1 rue Auguste Gasser Fax +33 3 89 76 58 71
68360 Soultz, France
Aquitaine/Char- SEW-USOCOME Tel. +33 5 57 26 39 08
ente Parc d'activités de Magellan Fax +33 5 57 26 39 09
62 avenue de Magellan - B.P.182
33607 Pessac Cedex, France
Auvergne/Limou- SEW-USOCOME Tel. +33 5 55 20 12 10
sin Farges Fax +33 5 55 20 12 11
19600 Chasteaux, France
Lower Normandy SEW-USOCOME Tel. +33 2 31 37 92 86
5 rue de la Limare Fax +33 2 31 74 68 15
14250 Brouay, France
Burgundy SEW-USOCOME Tel. +33 3 85 49 92 18
10 rue de la poste Fax +33 3 85 49 92 19
71350 Saint Loup Géanges, France
Brittany SEW-USOCOME Tel. +33 2 40 78 42 04
Parc d’activités de la forêt Fax +33 2 40 78 42 20
4 rue des Fontenelles
44140 Le Bignon, France
Centre/Poitou SEW-USOCOME Tel. +33 2 40 78 42 11
Parc d’activités de la forêt Fax +33 2 40 78 42 20
4 rue des Fontenelles
44140 Le Bignon, France
Champagne-Ard- SEW-USOCOME Tel. +33 3 25 79 63 24
enne 25 bis rue Victor Hugo Fax +33 3 25 79 63 25
Appartement 7
10120 Saint André les Vergers, France
Franche-Comté SEW-USOCOME Tel. +33 3 81 60 20 47
24 avenue Charles Boby Fax +33 3 81 87 75 93
70000 Quincey, France
Île-de-France SEW-USOCOME Tel. +33 3 23 62 81 24
19381212/EN – 03/2015

East/Aisne 20 rue Félix Faure Fax +33 3 23 62 81 44


02100 Saint Quentin, France
Île-de-France SEW-USOCOME Tel. +33 1 41 05 92 74
North/Picardy 25bis rue Kléber Fax +33 1 41 05 92 75
92300 Levallois Perret, France
Île-de-France SEW-USOCOME Tel. +33 1 60 81 10 56
South 6 chemin des bergers Fax +33 1 60 81 10 57
Lieu-dit Marchais
91410 Roinville sous Dourdan, France

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 399


14 Address Directory

France
Lothringen/North- SEW-USOCOME Tel. +33 3 83 96 28 04
ern Alsace 1 rue de la forêt Fax +33 3 83 96 28 07
54250 Champigneulles, France
Midi-Pyrénées/ SEW-USOCOME Tel. +33 5 61 08 15 85
Roussillon 179 route de Grazac Fax +33 5 61 08 16 44
31190 Caujac, France
Nord-Pas-de-Cal- SEW-USOCOME Tel. +33 3 21 10 86 86
ais 209, route d’Hesdigneul Fax +33 3 21 10 86 87
62360 Hesdin l’Abbé, France
Paris/Île-de- SEW-USOCOME Tel. +33 1 30 90 89 86
France West 42 avenue Jean Jaurès Fax +33 1 30 90 93 15
78580 Maule, France
Pays de la Loire SEW-USOCOME Tel. +33 2 40 78 42 03
Parc d’activités de la forêt Fax +33 2 40 78 42 20
4 rue des Fontenelles
44140 Le Bignon, France
Provence-Alpes- SEW-USOCOME Tel. +33 4 91 18 00 11
Côte d’Azur Le Clos Montolivet Fax +33 4 91 18 00 12
9 impasse Bounin – Bât. A
13012 Marseille, France
Rhône-Alpes East SEW-USOCOME Tel. +33 4 75 05 65 95
Montée de la Garenne Fax +33 4 75 05 65 96
26750 Génissieux, France
Rhône-Alpes SEW-USOCOME Tel. +33 4 72 15 37 03
North Parc d'affaires Roosevelt Fax +33 4 72 15 37 15
Rue Jacques Tati
69120 Vaulx en Velin, France
Rhône-Alpes SEW-USOCOME Tel. +33 4 72 15 37 04
West Parc d'affaires Roosevelt Fax +33 4 72 15 37 15
Rue Jacques Tati
69120 Vaulx en Velin, France

Algeria
Sales Algiers REDUCOM Sarl Tel. +213 21 8214-91
16, rue des Frères Zaghnoune Fax +213 21 8222-84
Bellevue [email protected]
16200 El Harrach Alger http://www.reducom-dz.com

Argentina
Assembly plant Buenos Aires SEW EURODRIVE ARGENTINA S.A. Tel. +54 3327 4572-84
Sales Ruta Panamericana Km 37.5, Lote 35 Fax +54 3327 4572-21
(B1619IEA) Centro Industrial Garín sewar@sew‑eurodrive.com.ar
Prov. de Buenos Aires http://www.sew-eurodrive.com.ar
Córdoba SEW EURODRIVE ARGENTINA S.A. Tel. +54 351-490-0010
Ruta Nacional 19, Manzana 97, Lote 5 [email protected]
(X5125) Malvinas Argentinas http://www.sew-eurodrive.com.ar
Prov. de Córdoba
Santa Fe SEW EURODRIVE ARGENTINA S.A. Tel. +54 341-317-7277
Ruta Prov. 21 Km 7, Lote 41 [email protected]
Parque Industrial Alvear http://www.sew-eurodrive.com.ar
(2126) Gral. Alvear
Prov. de Santa Fe
Service Mendoza SEW EURODRIVE ARGENTINA S.A. Tel. +54 261-430-0060
[email protected]
http://www.sew-eurodrive.com.ar
Technical offices Tucumán SEW EURODRIVE ARGENTINA S.A. Tel. +54 381-400-4569
Balcarce 609 [email protected]
19381212/EN – 03/2015

(T4000IAM) S.M. de Tucumán http://www.sew-eurodrive.com.ar


Prov. de Tucumán
Bahía Blanca SEW EURODRIVE ARGENTINA S.A. Tel. +54 291-451-7345
O'Higgins 95, 1er Piso A [email protected]
(B8000IVA) Bahía Blanca http://www.sew-eurodrive.com.ar
Prov. de Buenos Aires
Comahue SEW EURODRIVE ARGENTINA S.A. Tel. +54 299-478-1290
Puerto Rico 1885 [email protected]
(R8324IOE) Cipolletti http://www.sew-eurodrive.com.ar
Prov. de Río Negro

400 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Address Directory
14
Argentina
Mining Mendoza SEW EURODRIVE ARGENTINA S.A. Tel. +54 261-430-0060
[email protected]
http://www.sew-eurodrive.com.ar

Australia
Assembly plants Melbourne SEW‑EURODRIVE PTY. LTD. Tel. +61 3 9933-1000
Sales 27 Beverage Drive Fax +61 3 9933-1003
Service Tullamarine, Victoria 3043, Australia http://www.sew-eurodrive.com.au
enquires@sew‑eurodrive.com.au
Sydney SEW‑EURODRIVE PTY. LTD. Tel. +61 2 9725-9900
9, Sleigh Place, Wetherill Park Fax +61 2 9725-9905
New South Wales, 2164, Australia enquires@sew‑eurodrive.com.au
Sales Adelaide SEW‑EURODRIVE PTY. LTD. Tel. +61 8 8161 4000
Service 9C Park Way Fax +61 8 8161 4002
Mawson Lakes, SA 5095, Australia enquires@sew‑eurodrive.com.au
Brisbane SEW‑EURODRIVE PTY.LTD. Tel. +61 7 3276 5100
1 /34 Collinsvale St Fax +61 7 3276 5102
Rocklea, Queensland, 4106, Australia enquires@sew‑eurodrive.com.au
Perth SEW‑EURODRIVE PTY. LTD. Tel. +61 8 9251-4900
10 Colin Jamieson Drive Fax +61 8 9251-4903
Welshpool, WA 6106, Australia enquires@sew‑eurodrive.com.au
Sales Townsville SEW‑EURODRIVE PTY. LTD.
12 Leyland Street
Tel. +61 7 4779 4333
Fax +61 7 4779 5333
14
Garbutt, QLD 4814, Australia enquires@sew‑eurodrive.com.au

Austria
Assembly plant Vienna SEW‑EURODRIVE Ges.m.b.H. Tel. +43 1 617 55 00-0
Sales Richard-Strauss-Strasse 24 Fax +43 1 617 55 00-30
Service 1230 Wien, Austria http://www.sew-eurodrive.at
sew@sew‑eurodrive.at
Technical offices Linz SEW‑EURODRIVE Ges.m.b.H. Tel. +43 732 655 109-0
Reuchlinstr. 6/3 Fax +43 732 655 109-20
4020 Linz, Austria tb-linz@sew‑eurodrive.at
Graz SEW‑EURODRIVE Ges.m.b.H. Tel. +43 316 685 756-0
Grabenstraße 231 Fax +43 316 685 755
8045 Graz, Austria tb-graz@sew‑eurodrive.at
Dornbirn SEW‑EURODRIVE Ges.m.b.H. Tel. +43 5572 3725 99-0
Lustenauerstraße 27/1 Fax +43 5572 3725 99-20
6850 Dornbirn, Austria tb-dornbirn@sew‑eurodrive.at

Bangladesh
Sales Bangladesh SEW‑EURODRIVE INDIA PRIVATE LIMITED Mobile +88 01729 097309
345 DIT Road salesdhaka@seweurodrivebangla-
East Rampura desh.com
Dhaka-1219, Bangladesh

Belarus
Sales Minsk SEW‑EURODRIVE BY Tel. +375 17 298 47 56 / 298 47 58
RybalkoStr. 26 Fax +375 17 298 47 54
220033 Minsk, Belarus http://www.sew.by
[email protected]

Belgium
Assembly plant Brussels SEW‑EURODRIVE n.v./s.a. Tel. +32 16 386-311
Sales Researchpark Haasrode 1060 Fax +32 16 386-336
Service Evenementenlaan 7 http://www.sew-eurodrive.be
BE-3001 Leuven info@sew‑eurodrive.be
Service Competence Industrial gear SEW‑EURODRIVE n.v./s.a. Tel. +32 84 219-878
19381212/EN – 03/2015

Centers units Rue de Parc Industriel, 31 Fax +32 84 219-879


6900 Marche-en-Famenne, Belgium http://www.sew-eurodrive.be
service-wallonie@sew‑eurodrive.be

Brazil
Production plant São Paulo SEW‑EURODRIVE Brasil Ltda. Tel. +55 11 2489-9133
Sales Avenida Amâncio Gaiolli, 152 - Rodovia Presi- Fax +55 11 2480-3328
Service dente Dutra Km 208 http://www.sew-eurodrive.com.br
Guarulhos - 07251-250 - SP, Brazil [email protected]
SAT - SEW ATENDE - 0800 7700496

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 401


14 Address Directory

Brazil
Assembly plants Rio Claro SEW‑EURODRIVE Brasil Ltda. Tel. +55 19 3522-3100
Sales Rodovia Washington Luiz, Km 172 Fax +55 19 3524-6653
Service Condomínio Industrial Conpark [email protected]
Caixa Postal: 327
13501-600 – Rio Claro / SP
Joinville SEW‑EURODRIVE Brasil Ltda. Tel. +55 47 3027-6886
Rua Dona Francisca, 12.346 – Pirabeiraba Fax +55 47 3027-6888
89239-270 – Joinville / SC [email protected]
Indaiatuba SEW‑EURODRIVE Brasil Ltda. Tel. +55 19 3835-8000
Estrada Municipal Jose Rubim, 205 [email protected]
Rodovia Santos Dumont Km 49
13347-510 – Indaiatuba / SP

Bulgaria
Sales Sofia BEVER-DRIVE GmbH Tel. +359 2 9151160
Bogdanovetz Str.1 Fax +359 2 9151166
1606 Sofia, Bulgaria [email protected]

Cameroon
Sales Douala, Came- Electro-Services Tel. +237 33 431137
roon Rue Drouot Akwa Fax +237 33 431137
B.P. 2024 [email protected]
Douala, Cameroon

Canada
Assembly plants Toronto SEW-EURODRIVE CO. OF CANADA LTD. Tel. +1 905 791-1553
Sales 210 Walker Drive Fax +1 905 791-2999
Service Bramalea, ON L6T 3W1 http://www.sew-eurodrive.ca
l.watson@sew‑eurodrive.ca
Vancouver SEW-EURODRIVE CO. OF CANADA LTD. Tel. +1 604 946-5535
Tilbury Industrial Park Fax +1 604 946-2513
7188 Honeyman Street b.wake@sew‑eurodrive.ca
Delta, BC V4G 1G1
Montreal SEW-EURODRIVE CO. OF CANADA LTD. Tel. +1 514 367-1124
2555 Rue Leger Fax +1 514 367-3677
Lasalle, PQ H8N 2V9 a.peluso@sew‑eurodrive.ca
Please contact us for more addresses of service centers in Canada.

Chile
Assembly plant Santiago de Chile SEW‑EURODRIVE CHILE LTDA. Tel. +56 2 75770-00
Sales Las Encinas 1295 Fax +56 2 75770-01
Service Parque Industrial Valle Grande http://www.sew-eurodrive.cl
LAMPA ventas@sew‑eurodrive.cl
RCH-Santiago de Chile
P.O. box address
Casilla 23 Correo Quilicura - Santiago - Chile

China
Production plant Tianjin SEW‑EURODRIVE (Tianjin) Co., Ltd. Tel. +86 22 25322612
Assembly plant No. 46, 7th Avenue, TEDA Fax +86 22 25323273
Sales Tianjin 300457 info@sew‑eurodrive.cn
Service http://www.sew-eurodrive.cn
Assembly plant Suzhou SEW‑EURODRIVE (Suzhou) Co., Ltd. Tel. +86 51262581781
Sales 333, Suhong Middle Road Fax +86 512 62581783
Service Suzhou Industrial Park suzhou@sew‑eurodrive.cn
Jiangsu Province, 215021
Guangzhou SEW‑EURODRIVE (Guangzhou) Co., Ltd. Tel. +86 20 82267890
No. 9, JunDa Road Fax +86 20 82267922
East Section of GETDD guangzhou@sew‑eurodrive.cn
19381212/EN – 03/2015

Guangzhou 510530, China


Shenyang SEW‑EURODRIVE (Shenyang) Co., Ltd. Tel. +86 24 25382538
10A-2, 6th Road Fax +86 24 25382580
Shenyang Economic Technological Develop- shenyang@sew‑eurodrive.cn
ment Area
Shenyang, 110141, China

402 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Address Directory
14
China
Wuhan SEW‑EURODRIVE (Wuhan) Co., Ltd. Tel. +86 27 84478388
10A-2, 6th Road Fax +86 27 84478389
No. 59, the 4th Quanli Road, WEDA wuhan@sew‑eurodrive.cn
430056 Wuhan, China
Xi'An SEW‑EURODRIVE (Xi'An) Co., Ltd. Tel. +86 29 68686262
No. 12 Jinye 2nd Road Fax +86 29 68686311
Xi'An High-Technology Industrial Development xian@sew‑eurodrive.cn
Zone
Xi'An 710065

Colombia
Assembly plant Bogota SEW‑EURODRIVE COLOMBIA LTDA. Tel. +57 1 54750-50
Sales Calle 22 No. 132-60 Fax +57 1 54750-44
Service Bodega 6, Manzana B http://www.sew-eurodrive.com.co
Santafé de Bogotá, Colombia [email protected]

Côte d'Ivoire
Sales Abidjan SICA Tel. +225 21 25 79 44
Société Industrielle & Commerciale pour l'Afrique Fax +225 21 25 88 28
165, Boulevard de Marseille [email protected]
26 BP 1173 Abidjan 26

Croatia
14
Sales Zagreb KOMPEKS d. o. o. Tel. +385 1 4613-158
Service Zeleni dol 10 Fax +385 1 4613-158
10 000 Zagreb, Croatia [email protected]

Czech Republic
Sales Hostivice SEW‑EURODRIVE CZ S.R.O. Tel. +420 255 709 601
Assembly plant Floriánova 2459 Fax +420 235 350 613
Service 253 01 Hostivice http://www.sew-eurodrive.cz
sew@sew‑eurodrive.cz
Drive Service Hot- HOTLINE: +420 800 739 739 (800 SEW SEW) Service:
line/24-hour avail- Tel. +420 255 709 632
ability Fax +420 235 358 218
servis@sew‑eurodrive.cz
Assembly plant Plzeň SEW‑EURODRIVE CZ S.R.O. Tel. +420 378 775 320
Service Areal KRPA a.s. Fax +420 377 970 710
Zahradni 173/2 sew@sew‑eurodrive.cz
326 00 Plzeň
Technical offices Brno SEW‑EURODRIVE CZ S.R.O. Tel. +420 543 254 174
Křenová 52 Fax +420 543 256 845
60200 Brno [email protected]
Hradec Králové SEW‑EURODRIVE CZ S.R.O. Tel. +420 495 510 141
Čechova 498 Fax +420 495 521 313
50202 Hradec Králové [email protected]
Ostrava SEW‑EURODRIVE CZ S.R.O. Tel. +420 597 329 044
Studentská 6202/17 [email protected]
708 00 Ostrava-Poruba
Klatovy SEW‑EURODRIVE CZ S.R.O. Tel. +420 376 331 634
Vídeňská 841 Fax +420 376 331 634
33901 Klatovy [email protected]
Service Horní Moštěnice SEW‑EURODRIVE CZ S.R.O. Tel. +420 581 224 374
Nám.Dr.M.Tyrše 14/64 Fax +420 581 224 374
751 17 Horní Moštěnice servis@sew‑eurodrive.cz

Denmark
Assembly plant Copenhagen SEW‑EURODRIVE A/S Tel. +45 43 9585-00
19381212/EN – 03/2015

Sales Geminivej 28-30 Fax +45 43 9585-09


Service 2670 Greve, Denmark http://www.sew-eurodrive.dk
sew@sew‑eurodrive.dk

Egypt
Sales Cairo Copam Egypt Tel. +20 2 22566-299 +1 23143088
Service for Engineering & Agencies Fax +20 2 22594-757
33 EI Hegaz ST, Heliopolis, Cairo, Egypt http://www.copam-egypt.com/
[email protected]

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 403


14 Address Directory

Estonia
Sales Tallinn ALAS-KUUL AS Tel. +372 6593230
Reti tee 4 Fax +372 6593231
EE-75301 Peetri küla, Rae vald, Harjumaa, Esto- [email protected]
nia

Finland
Assembly plant Hollola SEW‑EURODRIVE OY Tel. +358 201 589-300
Sales Vesimäentie 4 Fax +358 3 780-6211
Service 15860 Hollola 2, Finland http://www.sew-eurodrive.fi
[email protected]
Service Hollola SEW‑EURODRIVE OY Tel. +358 201 589-300
Keskikankaantie 21 Fax +358 3 780-6211
FIN-15860 Hollola http://www.sew-eurodrive.fi
[email protected]
Technical offices Helsinki SEW‑EURODRIVE OY Tel. +358 201 589-300
Luutnantintie 5 [email protected]
00410 Helsinki, Finland
Vaasa SEW‑EURODRIVE OY Tel. +358 201 589-300
Asemakatu 7 [email protected]
65100 Vaasa, Finland
Kuopio SEW‑EURODRIVE OY Tel. +358 201 589-300
Viestikatu 3 [email protected]
70600 Kuopio, Finland
Production plant Karkkila SEW Industrial Gears Oy Tel. +358 201 589-300
Assembly plant Valurinkatu 6, PL 8 Fax +358 201 589-310
FI-03600 Karkkila, 03601 Karkkila [email protected]
http://www.sew-eurodrive.fi

Gabon
Sales Libreville, Gabon ESG Electro Services Gabun Tel. +241 741059
Feu Rouge Lalala Fax +241 741059
1889 Libreville [email protected]
Gabon

Greece
Sales Athens Christ. Boznos & Son S.A. Tel. +30 2 1042 251-34
12, K. Mavromichali Street Fax +30 2 1042 251-59
P.O. Box 80136 http://www.boznos.gr
GR-18545 Piraeus [email protected]
Technical office Thessaloniki Christ. Boznos & Son S.A. Tel. +30 2 310 7054-00
Asklipiou 26 Fax +30 2 310 7055-15
562 24 Evosmos, Thessaloniki, Greece [email protected]

Great Britain
Assembly plant Normanton SEW‑EURODRIVE Ltd. Tel. +44 1924 893-855
Sales DeVilliers Way Fax +44 1924 893-702
Service Trident Park http://www.sew-eurodrive.co.uk
Normanton info@sew‑eurodrive.co.uk
West Yorkshire
WF6 1GX
Drive Service Hotline/24-hour availability Tel. +44 1924 896911
Service Competence Southern England SEW‑EURODRIVE Ltd. Tel. +44 1189 701-699
Centers Unit 41 Fax +44 1189 701-021
Easter Park
Benyon Road
Silchester
Reading
Berkshire
19381212/EN – 03/2015

RG7 2PQ
Technical offices Midlands SEW‑EURODRIVE Ltd. Tel. +44 1527 877-319
5 Sugar Brook Court Fax +44 1527 575-245
Aston Road
Bromsgrove
Worcs.
B60 3EX

404 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Address Directory
14
Great Britain
Scotland SEW‑EURODRIVE Ltd. Tel. +44 17 8647-8730
No 37 Enterprise House Fax +44 17 8645-0223
Springkerse Business Park
Stirling
FK7 7UF

Hong Kong
Assembly plant Hong Kong SEW‑EURODRIVE LTD. Tel. +852 36902200
Sales Unit No. 801-806, 8th Floor Fax +852 36902211
Service Hong Leong Industrial Complex contact@sew‑eurodrive.hk
No. 4, Wang Kwong Road
Kowloon, Hong Kong

Hungary
Sales Budapest SEW‑EURODRIVE Kft. Tel. +36 1 437 06-58
Service 1037 Budapest, Hungary Fax +36 1 437 06-50
Kunigunda u. 18 http://www.sew-eurodrive.hu
[email protected]

India
Company office Vadodara SEW‑EURODRIVE India Private Limited Tel. +91 265 3045200, +91 265 2831086
Assembly plant Plot No. 4, GIDC Fax +91 265 3045300, +91 265 2831087
Sales POR Ramangamdi • Vadodara - 391 243, India http://www.seweurodriveindia.com
Service Gujarat [email protected] 14
Assembly plant Chennai SEW‑EURODRIVE India Private Limited Tel. +91 44 37188888
Sales Plot No. K3/1, Sipcot Industrial Park Phase II Fax +91 44 37188811
Service Mambakkam Village [email protected]
Sriperumbudur - 602105
Kancheepuram Dist, Tamil Nadu
Technical offices Ahmedabad SEW‑EURODRIVE India Private Limited Tel. +91 79 40072067/68
306, Shaan office complex, Behind Sakar-IV, Fax +91 79 40072069
Ellisebridge, Ashram Road salesahmedabad@seweurodrivein-
Ahmedabad – Gujarat, India dia.com
Aurangabad SEW‑EURODRIVE INDIA PRIVATE LIMITED Tel. +91 86000 12333
salesaurangabad@seweurodrivein-
dia.com
Bangalore SEW‑EURODRIVE India Private Limited Tel. +91 80 22266565
Sy.no:41-P3, Peenya1, Phase 1A, Peenya Vil- Fax +91 80 22266569
lage, Yeswanthapura Hobli, Bangalore North Ta- [email protected]
luk,
Bangalore Dist, Karnataka
SEW‑EURODRIVE India Private Limited Tel. +91 80 28522662 / 28522663
# C-104, 3rd Block, KSSIDC Complex, Electronic [email protected]
City.
Bangalore – 560100, Karnataka
Bangladesh SEW‑EURODRIVE INDIA PRIVATE LIMITED Mobile +88 01729 097309
Genetic Udayanchal, salesdhaka@seweurodrivebangla-
House-96 (6th Floor), Road-23/A, desh.com
Block-B, Banani, Dhaka-1213, Bangladesh
Bellary SEW‑EURODRIVE India Private Limited Tel. +91 77609 88668
Door no-56/279 Ward No-16, Sindhigi com- [email protected]
pound, Near Raghavendra talkies,
Bellary-583101
Karnataka
Chandigarh SEW‑EURODRIVE India Private Limited Tel. +91 81462 67606
# 72, Type- 4, Power Colony, saleschandigarh@seweurodrivein-
Chandigarh - Rupnagar Highway dia.com
Rupnagar- 140001, Punjab
19381212/EN – 03/2015

Chennai SEW‑EURODRIVE India Private Limited Tel. +91 44 42849813


2nd Floor, Josmans Complex, Fax +91 44 42849816
No. 5, McNichols Road, [email protected]
Chetpet
Chennai - 600031 - Tamil Nadu, India
Kochi SEW‑EURODRIVE India Private Limited Tel. +91 98951 30375
CF7-(2), Block No 1, Vasanth Nagar, [email protected]
Opposite Jawahar Lal Nehru Stadium,
Palarivattom – Cochin 682025

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 405


14 Address Directory

India
Coimbatore SEW‑EURODRIVE INDIA PRIVATE LIMITED Tel. +91 422 2322420
687/2, SRI SAKTHIVEL TOWERS (NEAR Fax +91 422 2323988
DEEPAM HOSPITAL) salescoimbatore@seweurodrivein-
TRICHY ROAD, RAMANATHAPURAM dia.com
COIMBATORE - 641 045.Tamilnadu, India
Cuttack SEW‑EURODRIVE India Private Limited Tel. +91 9937446333
Plot No. 1764, [email protected]
Nuasahi, Nayapalli
Bhubaneswar-12
Orissa
Gandhidham SEW‑EURODRIVE India Private Limited Tel. +91 81282 36850
TCX-S-28, FF, Ward 12/A, salesgandhidham@seweurodrivein-
Gandhidham - Kutch - 370201 dia.com
Hyderabad SEW‑EURODRIVE India Private Limited Tel. +91 40 23414698
408, 4th Floor, Meridian Place Fax +91 40 23413884
Green Park Road [email protected]
Amerpeet
Hyderabad - 500016 - Andhra Pradesh, India
Jamshedpur SEW‑EURODRIVE India Private Limited Tel. +91 9934123671
Flat no.: S1 " Kashi Kunj",h. No. 60, New Rani salesjamshedpur@seweurodrivein-
Kudar Road No - 3 dia.com
P.o. + P.s. - Kadma
Jamshedpur - Pin - 831005 Jharkhand
Kolhapur SEW EURODRIVE India Private Limited Tel. +91 86000 20846
[email protected]
Kolkata SEW EURODRIVE India Private Limited Tel. +91 33 22827457
2nd floor, Room No. 35 Fax +91 33 22894204
Chowringhee Court [email protected]
55, Chowringhee Road
Kolkata - 700 071 - West Bengal, India
Lucknow SEW‑EURODRIVE India Private Limited Tel. +91 9793627333
69, Shiv Vihar Colony [email protected]
Vikas Nagar-5
Lucknow 226022 - Uttar Pradesh
Mumbai SEW‑EURODRIVE India Private Limited Tel. +91 22 28348440
312 A, 3rd Floor, Acme Plaza, J.B. Nagar, Fax +91 22 28217858
Andheri Kurla Road, Andheri (E) [email protected]
Mumbai - 400059 - Maharashtra, India
Nagpur SEW‑EURODRIVE India Private Limited Tel. +91 95610 89525
Plot No 49, New Kailash Nager, Samta colony, [email protected]
Nagpur-440027
Nashik SEW‑EURODRIVE India Private Limited Tel. +91 9665752978
107, "YOG" Bunglow, [email protected]
Mahatama Nagar, Trimbak Road,
Nashik, Maharashtra – 422 007
New Delhi SEW‑EURODRIVE India Private Limited Tel. +91 11 25544111
1008, 10th Floor, 12th Level Fax +91 11 25544113
"Westend Mall" [email protected]
Tower Plot, District Centre
Adjacent Hotel Hilton
Janak Puri, New Delhi – 110058
Pune SEW‑EURODRIVE India Private Limited Tel. +91 20-65118890 / 91
Jai Tulajabhavani Complex. Fax +91 20 25380721
Office No: 15 First Floor, [email protected]
Opp. Century Enka Company,
MIDC Bhosari, Pune 411 026
SEW‑EURODRIVE India Private Limited Tel. +91 20 25380730/735
19381212/EN – 03/2015

LUNAWAT PRISM Fax +91 20 25380721


4th Floor, S.No. 148 [email protected]
Opposite Wanaz Company, Besides Mega Mart [email protected]
At Neena Co-Operative Housing Society, Paud
Road,
Pune 411038 - Maharashtra, India
Raipur SEW‑EURODRIVE India Private Limited Tel. +91 771 4090765
A-42, Ashoka Millenium Complex, Fax +91 771 4090765
Ring Road-1, [email protected]
Raipur 492 001 - Chhattisgarh, India

406 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Address Directory
14
India
Ranchi SEW‑EURODRIVE India Private Limited Tel. +91 8294630772
Flat No.: A - 101, [email protected]
Krishna Shree Apartment,
Anantpur, P.O. Doranda – Ranchi 834002
Tiruchirappalli SEW‑EURODRIVE India Private Limited Mobile +91 95009 88081
A-106,Trichy Towers, [email protected]
Chandrasekarapuram,
Salai Road,
Trichy – 620018.
Vadodara SEW‑EURODRIVE India Private Limited Tel. +91 265 2325258
Unit No. 301, Savorite Bldg, Fax +91 265 2325259
Plot No. 143, Vinayak Society, [email protected]
off old Padra Road,
Vadodara - 390 007. Gujarat
Vijayawada SEW‑EURODRIVE India Private Limited Tel. +91 99895 01748
Door No:40-5/3-10A, Syam Nagar, NGO's Colo- Fax +91 8662475157
ny, Mobile +91 9989501748
Tikkle Road, Vijayawada-520010 salesvijayawada@seweurodrivein-
dia.com

Indonesia
Sales Jakarta PT. Cahaya Sukses Abadi Tel. +62 21 65310599
Komplek Rukan Puri Mutiara Blok A no 99, Sunt- Fax +62 21 65310600 14
er [email protected]
Jakarta 14350, Indonesia
PT. Agrindo Putra Lestari Tel. +62 21 63855588
Jl.Prof.DR.Latumenten no27/A Fax +62 21 63853789
Jakarta 11330 [email protected]
Medan PT. Serumpun Indah Lestari Tel. +62 61 687 1221
Pulau Solor no. 8, Kawasan Industri Medan II Fax +62 61 6871429 / +62 61 6871458 /
Medan 20252 +62 61 30008041
[email protected]
[email protected]
Surabaya PT. TRIAGRI JAYA ABADI Tel. +62 31 5990128
Jl. Sukosemolo No. 63, Galaxi Bumi Permai G6 Fax +62 31 5962666
No. 11 [email protected]
Surabaya 60122
CV. Multi Mas Tel. +62 31 5458589 / +62 31 5317224
Jl. Raden Saleh 43A Kav. 18 Fax +62 31 5317220 / +62 31 5994629
Surabaya 60174 [email protected]

Ireland
Sales Dublin Alperton Engineering Ltd. Tel. +353 1 830-6277
Service 48 Moyle Road Fax +353 1 830-6458
Dublin Industrial Estate [email protected]
Glasnevin, Dublin 11, Ireland http://www.alperton.ie

Iceland
Sales Reykjavik VARMA & VELAVERK EHF Tel. +354 585 1070
Dalshrauni 5 Fax +354 585 1071
IS-220 Hafnarjördur [email protected]
http://www.varmaverk.is

Israel
Sales Tel Aviv Liraz Handasa Ltd. Tel. +972 3 5599511
Ahofer Str 34B / 228 Fax +972 3 5599512
58858 Holon, Israel http://www.liraz-handasa.co.il
[email protected]
19381212/EN – 03/2015

Italy
Assembly plant Solaro SEW‑EURODRIVE di R. Blickle & Co.s.a.s. Tel. +39 02 96 9801
Sales Via Bernini,14 Fax +39 02 96 980 999
Service I-20020 Solaro (Milano), Italy http://www.sew-eurodrive.it
sewit@sew‑eurodrive.it
Technical offices Bologna SEW‑EURODRIVE di R. Blickle & Co.s.a.s. Tel. +39 051 65-23-801
Via della Grafica, 47 Fax +39 02 96 980 499
40064 Ozzano dell'Emilia (Bo), Italy

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 407


14 Address Directory

Italy
Caserta SEW‑EURODRIVE di R. Blickle & Co.s.a.s. Tel. +39 0823 219011
Viale Carlo III Km. 23,300 Fax +39 02 96 980 599
81020 S. Nicola la Strada (Caserta), Italy
Milan SEW‑EURODRIVE di R. Blickle & Co.s.a.s. Tel. +39 02 96 980229
Via Bernini,14 Fax +39 02 96 980 999
I-20020 Solaro (Milano), Italy
Pescara SEW‑EURODRIVE di R. Blickle & Co.s.a.s. Tel. +39 085 41-59-427
Viale Europa,132 Fax +39 02 96 980 699
I-65010 Villa Raspa di Spoltore (PE)
Turin SEW‑EURODRIVE di R. Blickle & Co.s.a.s. Tel. +39 011 3473780
Filiale Torino Fax +39 02 96 980 799
c.so Unione Sovietica 612/15 - int. C
10135 Torino, Italy
Verona SEW‑EURODRIVE di R. Blickle & Co.s.a.s. Tel. +39 045 89-239-11
Via Antonio Meucci 5, Fax +39 02 96 980 814
I-37042 - Caldiero ( VR )

Japan
Assembly plant Iwata SEW‑EURODRIVE JAPAN CO., LTD Tel. +81 538 373811
Sales 250-1, Shimoman-no, Fax +81 538 373855
Service Iwata http://www.sew-eurodrive.co.jp
Shizuoka 438-0818 sewjapan@sew‑eurodrive.co.jp
Technical offices Fukuoka SEW‑EURODRIVE JAPAN CO., LTD. Tel. +81 92 713-6955
C-go, 5th-floor, Yakuin-Hiruzu-Bldg. Fax +81 92 713-6860
1-5-11, Yakuin, Chuo-ku [email protected]
Fukuoka, 810-0022, Japan
Osaka SEW‑EURODRIVE JAPAN CO., LTD. Tel. +81 6 6444--8330
Higobashi Shimizu Bldg. 10th floor Fax +81 6 6444--8338
1-3-7 Tosabori, Nishi-ku [email protected]
Osaka, 550-0001, Japan
Tokyo SEW‑EURODRIVE JAPAN CO., LTD. Tel. +81 3 3239-0469
Omarimon Yusen Bldg. 13th floor Fax +81 3 3239-0943
3-23-5 Nishinbashi, Minato-ku [email protected]
Tokyo 105-0003, Japan

Kazakhstan
Sales Almaty ТОО "СЕВ-ЕВРОДРАЙВ" Тел. +7 (727) 334 1880
пр.Райымбека, 348 Факс +7 (727) 334 1881
050061 г. Алматы http://www.sew-eurodrive.kz
Республика Казахстан sew@sew‑eurodrive.kz

Kenya
Sales Nairobi Barico Maintenances Ltd Tel. +254 20 6537094/5
Kamutaga Place Fax +254 20 6537096
Commercial Street [email protected]
Industrial Area
P.O.BOX 52217 - 00200
Nairobi

Latvia
Sales Riga SIA Alas-Kuul Tel. +371 6 7139253
Katlakalna 11C Fax +371 6 7139386
1073 Riga, Latvia http://www.alas-kuul.com
[email protected]

Lebanon
Sales Lebanon Beirut Gabriel Acar & Fils sarl Tel. +961 1 510 532
B. P. 80484 Fax +961 1 494 971
Bourj Hammoud, Beirut, Lebanon [email protected]
19381212/EN – 03/2015

After Sales Service [email protected]


Sales Jordan / Ku- Beirut Middle East Drives S.A.L. (offshore) Tel. +961 1 494 786
wait / Saudi Arabia / Sin El Fil. Fax +961 1 494 971
Syria B. P. 55-378 [email protected]
Beirut http://www.medrives.com
After Sales Service [email protected]

408 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Address Directory
14
Lithuania
Sales Alytus UAB Irseva Tel. +370 315 79204
Statybininku 106C Fax +370 315 56175
LT-63431 Alytus [email protected]
http://www.sew-eurodrive.lt

Luxembourg
Assembly plant Brussels SEW‑EURODRIVE n.v./s.a. Tel. +32 16 386-311
Sales Researchpark Haasrode 1060 Fax +32 16 386-336
Service Evenementenlaan 7 http://www.sew-eurodrive.lu
BE-3001 Leuven info@sew‑eurodrive.be

Madagascar
Sales Antananarivo Ocean Trade Tel. +261 20 2330303
BP21bis. Andraharo Fax +261 20 2330330
Antananarivo. [email protected]
101 Madagascar

Malaysia
Assembly plant Johor SEW‑EURODRIVE SDN BHD Tel. +60 7 3549409
Sales No. 95, Jalan Seroja 39, Taman Johor Jaya Fax +60 7 3541404
Service 81000 Johor Bahru, Johor sales@sew‑eurodrive.com.my
West Malaysia
Technical offices Kuala Lumpur SEW‑EURODRIVE Sdn. Bhd. Tel. +60 3 51229633 14
No. 2, Jalan Anggerik Mokara 31/46 Fax +60 3 51229622
Kota Kemuning Seksyen 31 [email protected]
40460 Shah Alam
Selangor Darul Ehsan
Kuching SEW‑EURODRIVE Sdn. Bhd. Tel. +60 82 232380
Lot 268, Section 9 KTLD Fax +60 82 242380
Lorong 9, Jalan Satok
93400 Kuching, Sarawak
East Malaysia
Penang SEW‑EURODRIVE Sdn. Bhd. Tel. +60 4 3999349
No. 38, Jalan Bawal Fax +60 4 3999348
Kimsar Garden [email protected]
13700 Prai, Penang

Morocco
Sales Mohammedia SEW‑EURODRIVE SARL Tel. +212 523 32 27 80/81
Service 2 bis, Rue Al Jahid Fax +212 523 32 27 89
28810 Mohammedia sew@sew‑eurodrive.ma
http://www.sew-eurodrive.ma

Mauritania
Sales Zouérat AFRICOM - SARL Tel. +222 45 44 50 19
En Face Marché Dumez Fax +222 45 44 03 14
P.B. 88 [email protected]
Zouérate

Macedonia
Sales Skopje Boznos DOOEL Tel. +389 23256553
Dime Anicin 2A/7A Fax +389 23256554
1000 Skopje http://www.boznos.mk

Mexico
Assembly plant Quéretaro SEW‑EURODRIVE MEXICO SA DE CV Tel. +52 442 1030-300
Sales SEM-981118-M93 Fax +52 442 1030-301
Service Tequisquiapan No. 102 http://www.sew-eurodrive.com.mx
Parque Industrial Quéretaro [email protected]
19381212/EN – 03/2015

C.P. 76220
Quéretaro, Mexico

Mongolia
Sales Ulan Bator SEW-EURODRIVE Representative Office Mon- Tel. +976-70009997
golia Fax +976-70009997
Olympic street 8, http://www.sew-eurodrive.mn
2nd floor Juulchin corp bldg., [email protected]
Sukhbaatar district,
Ulaanbaatar 14253

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 409


14 Address Directory

Namibia
Sales Swakopmund DB Mining & Industrial Services Tel. +264 64 462 738
Einstein Street Fax +264 64 462 734
Strauss Industrial Park [email protected]
Unit1
Swakopmund

New Zealand
Assembly plants Auckland SEW‑EURODRIVE NEW ZEALAND LTD. Tel. +64 9 2745627
Sales P.O. Box 58-428 Fax +64 9 2740165
Service 82 Greenmount Drive http://www.sew-eurodrive.co.nz
East Tamaki Auckland, New Zealand sales@sew‑eurodrive.co.nz
Christchurch, SEW‑EURODRIVE NEW ZEALAND LTD. Tel. +64 3 384-6251
New Zealand 10 Settlers Crescent, Ferrymead Fax +64 3 384-6455
Christchurch, New Zealand sales@sew‑eurodrive.co.nz
Technical offices Palmerston North SEW‑EURODRIVE NEW ZEALAND LTD. Tel. +64 6 355-2165
C/-Grant Shearman, RD 5, Aronui Road Fax +64 6 355-2316
Palmerston North sales@sew‑eurodrive.co.nz

Netherlands
Assembly plant Rotterdam SEW‑EURODRIVE B.V. Tel. +31 10 4463-700
Sales Industrieweg 175 Fax +31 10 4155-552
Service 3044 AS Rotterdam, Netherlands Service: 0800-SEWHELP
Postbus 10085 http://www.sew-eurodrive.nl
3004 AB Rotterdam, Netherlands info@sew‑eurodrive.nl

Nigeria
Sales Lagos EISNL Engineering Solutions and Drives Ltd Tel. +234 1 217 4332
Plot 9, Block A, Ikeja Industrial Estate (Ogba [email protected]
Scheme) http://www.eisnl.com
Adeniyi Jones St. End
Off ACME Road, Ogba, Ikeja, Lagos
Nigeria

Norway
Assembly plant Moss SEW‑EURODRIVE A/S Tel. +47 69 24 10 20
Sales Solgaard skog 71 Fax +47 69 24 10 40
Service 1599 Moss, Norway http://www.sew-eurodrive.no
sew@sew‑eurodrive.no

Pakistan
Sales Karatschi Industrial Power Drives Tel. +92 21 452 9369
Al-Fatah Chamber A/3, 1st Floor Central Com- Fax +92-21-454 7365
mercial Area, [email protected]
Sultan Ahmed Shah Road, Block 7/8,
Karachi

Paraguay
Sales Fernando de la SEW-EURODRIVE PARAGUAY S.R.L Tel. +595 991 519695
Mora De la Victoria 112, Esquina nueva Asunción Fax +595 21 3285539
Departamento Central [email protected]
Fernando de la Mora, Barrio Bernardino

Peru
Assembly plant Lima SEW DEL PERU MOTORES REDUCTORES Tel. +51 1 3495280
Sales S.A.C. Fax +51 1 3493002
Service Los Calderos, 120-124 http://www.sew-eurodrive.com.pe
Urbanizacion Industrial Vulcano, ATE, Lima, Pe- sewperu@sew‑eurodrive.com.pe
ru

Philippines
19381212/EN – 03/2015

Sales Luzon Totaltech Corporation Tel. +63 2 551-9265 / +63 2 551-9271 /


5081-B C&L Mansion Filmore Ave. Cor. Fahren- +63 2 551-9378
heit St. Fax +63 2 551-9273
1235 Makati City [email protected]
All Areas P.T. Cerna Corporation Tel. +63 2 519 6214
4137 Ponte St., Brgy. Santa Cruz, Makati City Fax +63 2 890 2802
1205 [email protected]

410 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Address Directory
14
Poland
Assembly plant Łódź SEW‑EURODRIVE Polska Sp.z.o.o. Tel. +48 42 676 53 00
Sales ul. Techniczna 5 Fax +48 42 676 53 49
Service 92-518 Łódź, Poland http://www.sew-eurodrive.pl
sew@sew‑eurodrive.pl
Service Tel. +48 42 6765332 / 42 6765343 Linia serwisowa 24 hour hotline
Fax +48 42 6765346 Tel. +48 602 739 739
(+48 602 SEW SEW)
serwis@sew‑eurodrive.pl
Technical office Tychy SEW‑EURODRIVE Polska Sp.z.o.o. Tel. +48 32 32 32 610
ul. Strzelecka 66 Fax +48 32 32 32 648
PL-43-109 Tychy
Bydgoszcz SEW‑EURODRIVE Polska Sp.z.o.o. Tel. +48 52 3606590
ul. Fordońska 246 Fax +48 52 3606591
PL-85-959 Bydgoszcz
Gdansk SEW‑EURODRIVE Polska Sp.z.o.o. Tel. +48 58 762 70 00
ul. Galaktyczna 30A Fax +48 58 762 70 09
PL-80-299 Gdańsk
Poznan SEW‑EURODRIVE Polska Sp.z.o.o. Tel. +48 61 6465500
ul. Romana Maya 1 Fax +48 61 6465519
61-371 Poznań, Poland
Radom SEW‑EURODRIVE Polska Sp.z.o.o. Tel. +48 48 365 40 50
ul. Słowackiego 84 Fax +48 48 365 40 52 14
26-600 Radom, Poland

Portugal
Assembly plant Coimbra SEW‑EURODRIVE, LDA. Tel. +351 231 20 9670
Sales Apartado 15 Fax +351 231 20 3685
Service 3050-901 Mealhada, Portugal http://www.sew-eurodrive.pt
infosew@sew‑eurodrive.pt
Service Competence Lisbon SEW‑EURODRIVE, LDA. Tel. +351 21 958-0198
Centers Núcleo Empresarial I de São Julião do Tojal Fax +351 21 958-0245
Rua de Entremuros, 54 esc.lisboa@sew‑eurodrive.pt
Fracção I
2660-533 São Julião do Tojal, Portugal
Technical office Porto SEW‑EURODRIVE, LDA. Tel. +351 229 350 383
Av. 25 de Abril, 68 Fax +351 229 350 384
4440-502 Valongo, Portugal Tel. +351 9 32559110
esc.porto@sew‑eurodrive.pt

Romania
Sales Bucharest Sialco Trading SRL Tel. +40 21 230-1328
Service str. Brazilia nr. 36 Fax +40 21 230-7170
011783 Bucuresti, Romania [email protected]

Russia
Assembly plant St. Petersburg ZAO SEW‑EURODRIVE Tel. +7 812 3332522 +7 812 5357142
Sales P.O. Box 36 Fax +7 812 3332523
Service RUS-195220 St. Petersburg http://www.sew-eurodrive.ru
sew@sew‑eurodrive.ru
Technical office Ekaterinburg ZAO SEW‑EURODRIVE Tel. +7 343 310 3977
Kominterna Str. 16 Fax +7 343 310 3978
Office 614 eso@sew‑eurodrive.ru
620078 Ekaterinburg, Russia
Irkutsk ZAO SEW‑EURODRIVE Tel. +7 3952 25 5880
5-Armii Str., 31 Fax +7 3952 25 5881
664011 Irkutsk, Russia iso@sew‑eurodrive.ru
Moscow ZAO SEW‑EURODRIVE Tel. +7 495 9337090
Malaja Semjonowskaja Str. Fax +7 495 9337094
19381212/EN – 03/2015

д. 9, корпус 2 mso@sew‑eurodrive.ru
107023 Moscow
Novosibirsk ZAO SEW‑EURODRIVE Tel. +7 383 3350200
pr. K Marksa 30 Fax +7 383 3462544
630087 Novosibirsk, Russia nso@sew‑eurodrive.ru
Perm ZAO SEW‑EURODRIVE Tel. +7 342 2219494
Stakhanovskaya str., 45 Office 512 Fax +7 342 2219444
RUS-614066 Perm [email protected]

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 411


14 Address Directory

Russia
Togliatti ZAO SEW‑EURODRIVE Tel. +7 8482 710529
Sportivnaya Str. 4B, office 2 Fax +7 8482 810590
Samarskaya obl.
445057 Togliatti, Russia

Senegal
Sales Dakar SENEMECA Tel. +221 338 494 770
Mécanique Générale Fax +221 338 494 771
Km 8, Route de Rufisque [email protected]
B.P. 3251, Dakar http://www.senemeca.com

Serbia
Sales Belgrade DIPAR d.o.o. Tel. +381 11 347 3244 / +381 11 288
Ustanicka 128a 0393
PC Košum, IV sprat Fax +381 11 347 1337
SRB-11000 Beograd, Serbia [email protected]

Singapore
Assembly plant Singapore SEW‑EURODRIVE PTE. LTD. Tel. +65 68621701
Sales No 9, Tuas Drive 2 Fax +65 68612827
Service Jurong Industrial Estate http://www.sew-eurodrive.com.sg
Singapore 638644 sewsingapore@sew‑eurodrive.com

Slovakia
Sales Bratislava SEW‑EURODRIVE SK s.r.o. Tel. +421 2 33595 202
Rybničná 40 Fax +421 2 33595 200
831 06 Bratislava, Slovakia sew@sew‑eurodrive.sk
http://www.sew-eurodrive.sk
Žilina SEW‑EURODRIVE SK s.r.o. Tel. +421 41 700 2513
Industry Park - PChZ Fax +421 41 700 2514
ulica M.R.Štefánika 71 sew@sew‑eurodrive.sk
010 01 Žilina, Slovakia
Banska Bystrica SEW‑EURODRIVE SK s.r.o. Tel. +421 48 414 6564
Rudlovská cesta 85 Fax +421 48 414 6566
974 11 Banská Bystrica, Slovakia sew@sew‑eurodrive.sk
Košice SEW‑EURODRIVE SK s.r.o. Tel. +421 55 671 2245
Slovenská ulica 26 Fax +421 55 671 2254
040 01 Košice, Slovakia sew@sew‑eurodrive.sk

Slovenia
Sales Celje Pakman - Pogonska Tehnika d.o.o. Tel. +386 3 490 83-20
Service UI. XIV. divizije 14 Fax +386 3 490 83-21
3000 Celje, Slovenia [email protected]

Spain
Assembly plant Bilbao SEW‑EURODRIVE ESPAÑA, S.L. Tel. +34 94 43184-70
Sales Parque Tecnológico, Edificio, 302 Fax +34 94 43184-71
Service 48170 Zamudio (Vizcaya), Spain http://www.sew-eurodrive.es
sew.spain@sew‑eurodrive.es
Technical offices Barcelona Delegación Barcelona Tel. +34 93 7162200
Avda. Francesc Macià, 60 – Planta 16, porta 1 Fax +34 93 7233007
Eix Macià – "Torre Milenium"
08208 Sabadell (Barcelona), Spain
Madrid Delegación Madrid Tel. +34 91 6342250
Gran Via. 48-2° A-D Fax +34 91 6340899
28220 Majadahonda (Madrid), Spain
Sevilla MEB Tel. +34 954 356 361
Pólogono Calonge, C/A Nave 2 - C Fax +34 954 356 274
E-41.077 Sevilla, Spain [email protected]
19381212/EN – 03/2015

Valencia MEB Tel. +34 961 565 493


Músico Andreu i Piqueres, 4 Fax +34 961 566 688
E-46.900 Torrente (Valencia) [email protected]

Sri Lanka
Sales Colombo SM International (Pte) Ltd Tel. +94 1 2584887
254, Galle Raod Fax +94 1 2582981
Colombo 4, Sri Lanka

412 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Address Directory
14
South Africa
Assembly plants Johannesburg SEW‑EURODRIVE (PROPRIETARY) LIMITED Tel. +27 11 248-7000
Sales Eurodrive House Fax +27 11 494-3104
Service Cnr. Adcock Ingram and Aerodrome Roads http://www.sew.co.za
Aeroton Ext. 2 [email protected]
Johannesburg 2013, South Africa
P.O.Box 90004
Bertsham 2013, South Africa
Cape Town SEW‑EURODRIVE (PROPRIETARY) LIMITED Tel. +27 21 552-9820
Rainbow Park Fax +27 21 552-9830
Cnr. Racecourse & Omuramba Road Telex 576 062
Montague Gardens [email protected]
Cape Town, South Africa
P.O. Box 36556
Chempet 7442
Cape Town, South Africa
Durban, South Af- SEW‑EURODRIVE (PROPRIETARY) LIMITED Tel. +27 31 902 3815
rica 48 Prospecton Road Fax +27 31 902 3826
Isipingo [email protected]
Durban, South Africa
P.O. Box 10433, Ashwood 3605, South Africa
Nelspruit SEW‑EURODRIVE (PTY) LTD. Tel. +27 13 752-8007
7 Christie Crescent Fax +27 13 752-8008
Vintonia [email protected] 14
P.O. Box 1942
Nelspruit 1200
Technical offices Port Elizabeth SEW‑EURODRIVE PTY LTD. Tel. +27 41 3722246
8 Ruan Access Park Fax +27 41 3722247
Old Cape Road [email protected]
Greenbushes
6000 Port Elizabeth

South Korea
Assembly plant Ansan SEW‑EURODRIVE KOREA CO., LTD. Tel. +82 31 492-8051
Sales B 601-4, Banweol Industrial Estate Fax +82 31 492-8056
Service #1048-4, Shingil-Dong, Danwon-Gu, http://www.sew-korea.co.kr
Ansan-City, Kyunggi-Do Zip 425-839 master.korea@sew‑eurodrive.com
Busan SEW‑EURODRIVE KOREA Co., Ltd. Tel. +82 51 832-0204
No. 1720 - 11, Songjeong - dong Fax +82 51 832-0230
Gangseo-ku [email protected]
Busan 618-270, Korea
Technical offices Daegu SEW‑EURODRIVE KOREA Co., Ltd. Tel. +82 53 650-7111
No.1108 Sungan officetel Fax +82 53 650-7112
87-36, Duryu 2-dong, Dalseo-ku
Daegu 704-712
Daejeon SEW‑EURODRIVE KOREA Co., Ltd. Tel. +82 42 828-6461
No. 1502, Hongin officetel Fax +82 42 828-6463
536-9, Bongmyung-dong, Yusung-ku
Daejeon 305-301
Gwangju SEW‑EURODRIVE KOREA Co., Ltd. Tel. +82 62 511-9172
4fl., Dae-Myeong B/D Fax +82 62 511-9174
96-16 Unam-dong, Buk-ku
Kwangju 500-170
Seoul SEW‑EURODRIVE KOREA Co., Ltd. Tel. +82 2 862-8051
No.504 Sunkyung officetel Fax +82 2 862-8199
106-4 Kuro 6-dong, Kuro-ku
Seoul 152-054, Korea

Swaziland
19381212/EN – 03/2015

Sales Manzini C G Trading Co. (Pty) Ltd Tel. +268 2 518 6343
PO Box 2960 Fax +268 2 518 5033
Manzini M200 [email protected]

Sweden
Assembly plant Jönköping SEW-EURODRIVE AB Tel. +46 36 3442 00
Sales Gnejsvägen 6-8 Fax +46 36 3442 80
Service 55303 Jönköping, Sweden http://www.sew-eurodrive.se
Box 3100 S-55003 Jönköping [email protected]

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 413


14 Address Directory

Sweden
Sales Göteborg SEW-EURODRIVE AB Tel. +46 31 70968 80
Gustaf Werners gata 8 Fax +46 31 70968 93
42132 Västra Frölunda, Sweden [email protected]
Stockholm SEW-EURODRIVE AB Tel. +46 8 44986 80
Björkholmsvägen 10 Fax +46 8 44986 93
14146 Huddinge, Sweden [email protected]
Malmö SEW-EURODRIVE AB Tel. +46 40 68064 80
Borrgatan 5 Fax +46 40 68064 93
21124 Malmö, Sweden [email protected]
Skellefteå SEW-EURODRIVE AB Tel. +46 910 7153 80
Trädgårdsgatan 8 Fax +46 910 7153 93
93131 Skellefteå, Sweden [email protected]

Switzerland
Assembly plant Basel Alfred lmhof A.G. Tel. +41 61 417 1717
Sales Jurastrasse 10 Fax +41 61 417 1700
Service CH-4142 Münchenstein bei Basel http://www.imhof-sew.ch
[email protected]
Technical offices Romandy André Gerber Tel. +41 24 445 3850
Es Perreyres Fax +41 24 445 4887
1436 Chamblon, Switzerland
Bern / Solothurn Rudolf Bühler Tel. +41 32 652 2339
Muntersweg 5 Fax +41 32 652 2331
2540 Grenchen, Switzerland
Central Switzer- Armin Pfister Tel. +41 62 962 54 55
land, Aargau Stierenweid Fax +41 62 962 54 56
4950 Huttwill, BE, Switzerland
Zurich, Tessin Gian-Michele Muletta Tel. +41 44 994 81 15
Fischerstrasse 61 Fax +41 44 994 81 16
8132 Egg bei Zürich, Switzerland
Lake Constance Markus Künzle Tel. +41 71 845 2808
and Eastern Swit- Eichweg 4 Fax +41 71 845 2809
zerland 9403 Goldach, Switzerland

Taiwan (R.O.C.)
Sales Nan Tou Ting Shou Trading Co., Ltd. Tel. +886 49 255353
No. 55 Kung Yeh N. Road Fax +886 49 257878
Industrial District
Nan Tou 540
Taipei Ting Shou Trading Co., Ltd. Tel. +886 2 27383535
6F-3, No. 267, Sec. 2 Fax +886 2 27368268
Tung Hwa South Road, Taipei, Taiwan Telex 27 245
[email protected]

Tanzania
Sales Dar es Salaam SEW-EURODRIVE PTY LIMITED TANZANIA Tel. +255 0 22 277 5780
Plot 52, Regent Estate Fax +255 0 22 277 5788
PO Box 106274 [email protected]
Dar Es Salaam

Thailand
Assembly plant Chonburi SEW‑EURODRIVE (Thailand) Ltd. Tel. +66 38 454281
Sales 700/456, Moo.7, Donhuaroh Fax +66 38 454288
Service Muang sewthailand@sew‑eurodrive.com
Chonburi 20000, Thailand
Technical offices Bangkok SEW‑EURODRIVE (Thailand) Ltd. Tel. +66 2 7178149
6th floor, TPS Building Fax +66 2 7178152
1023, Phattanakarn Road sewthailand@sew‑eurodrive.com
19381212/EN – 03/2015

Suanluang
Bangkok,10250
Hat Yai SEW‑EURODRIVE (Thailand) Ltd. Tel. +66 74 359441
Hadyai Country Home Condominium Fax +66 74 359442
59/101 Soi.17/1 sewthailand@sew‑eurodrive.com
Rachas-Utid Road.
Hadyai, Songkhla 90110, Thailand

414 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Address Directory
14
Thailand
Khon Kaen SEW‑EURODRIVE (Thailand) Ltd. Tel. +66 43 225745
4th Floor, Kaow-U-HA MOTOR Bldg, Fax +66 43 324871
359/2, Mitraphab Road. sew-thailand@sew‑eurodrive.com
Muang District
Khonkaen 40000, Thailand

Tunisia
Sales Tunis T. M.S. Technic Marketing Service Tel. +216 79 40 88 77
Zone Industrielle Mghira 2 Fax +216 79 40 88 66
Lot No. 39 http://www.tms.com.tn
2082 Fouchana [email protected]

Turkey
Assembly plant Kocaeli-Gebze SEW-EURODRİVE Tel. +90-262-9991000-04
Sales Sistemleri San. Ve TIC. Ltd. Sti Fax +90-262-9991009
Service Gebze Organize Sanayi Böl. 400 Sok No. 401 http://www.sew-eurodrive.com.tr
41480 Gebze Kocaeli sew@sew‑eurodrive.com.tr
Technical offices Adana SEW-EURODRİVE Tel. +90 322 359 94 15
Cevat Yurdakul Cad.No:52 Fax +90 322 359 94 16
Akdoğan İş Merkezi K:5 D.18
Seyhan / Adana
Ankara SEW-EURODRİVE Tel. +90 312 385 33 90
1368.Cadde Eminel İşmerkezi Fax +90 312 385 32 58 14
No: 18/68
İvogsan / Ankara
Bursa SEW-EURODRİVE Tel. +90 224 443 45 60
Üçevler Mah. Bayraktepe Sok. Fax +90 224 443 45 58
Akay İş Merkezi Kat:3 No: 7/6
Nilüfer / Bursa
Istanbul SEW-EURODRİVE Tel. +90-262-9991000-04
Tekstilkent Ticaret Merkezi Fax +90-262-9991009
B-13 Blok No:70
Esenler / İstanbul
Izmir SEW-EURODRİVE Tel. +90 232 469 62 64
1203/11 Sok. No. 4/614 Fax +90 232 433 61 05
Kara Hasan Atlı İş Merkezi Kat :6
Yenişehir / İzmir

Ukraine
Assembly plant Dnipropetrowsk ООО «СЕВ-Евродрайв» Тел. +380 56 370 3211
Sales ул.Рабочая, 23-B, офис 409 Факс. +380 56 372 2078
Service 49008 Днепропетровск http://www.sew-eurodrive.ua
sew@sew‑eurodrive.ua
Sales Kiev ООО «СЕВ-Евродрайв» Тел. +380 44 503 95 77
ул.С.Олейника, 21 Факс. +380 44 503 95 78
02068 Киев kso@sew‑eurodrive.ua
Donetsk ООО «СЕВ-Евродрайв» Тел. +380 62 38 80 545
ул.25-летия РККА, 1-B, оф. 805 Факс. +380 62 38 80 533
83000 Донецк dso@sew‑eurodrive.ua
Ivano-Frankivsk ООО «СЕВ-Евродрайв» Тел. +380 342 725 190
ул.Независимости, 4, оф.303 Факс. +380 342 725 191
83000 Ивано-Франковск [email protected]

Uruguay
Assembly plant Montevideo SEW‑EURODRIVE Uruguay, S. A. Tel. +598 2 21181-89
Sales Jose Serrato 3569 Esqina Corumbe Fax +598 2 21181-89
CP 12000 Montevideo sewuy@sew‑eurodrive.com.uy

USA
19381212/EN – 03/2015

Production plant Southeast Region SEW‑EURODRIVE INC. Tel. +1 864 439-7537


Assembly plant 1295 Old Spartanburg Highway Fax Sales +1 864 439-7830
Sales P.O. Box 518 Fax Manufacturing +1 864 439-9948
Service Lyman, S.C. 29365 Fax Assembly +1 864 439-0566
Fax Confidential/HR +1 864 949-5557
http://www.seweurodrive.com
[email protected]

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 415


14 Address Directory

USA
Assembly plants Northeast Region SEW‑EURODRIVE INC. Tel. +1 856 467-2277
Sales Pureland Ind. Complex Fax +1 856 845-3179
Service 2107 High Hill Road, P.O. Box 481 [email protected]
Bridgeport, New Jersey 08014, USA
Midwest Region SEW‑EURODRIVE INC. Tel. +1 937 335-0036
2001 West Main Street Fax +1 937 332-0038
Troy, Ohio 45373, USA [email protected]
Southwest SEW‑EURODRIVE INC. Tel. +1 214 330-4824
Region 3950 Platinum Way Fax +1 214 330-4724
Dallas, Texas 75237, USA [email protected]
Western Region SEW‑EURODRIVE INC. Tel. +1 510 487-3560
30599 San Antonio St. Fax +1 510 487-6433
Hayward, CA 94544, USA [email protected]
Please contact us for other service center addresses in the USA.

Venezuela
Assembly plant Valencia SEW‑EURODRIVE Venezuela S.A. Tel. +58 241 832-9804
Sales Av. Norte Sur No. 3, Galpon 84-319 Fax +58 241 838-6275
Service Zona Industrial Municipal Norte http://www.sew-eurodrive.com.ve
Valencia, Estado Carabobo, Venezuela ventas@sew‑eurodrive.com.ve
[email protected]

United Arab Emirates


Sales Sharjah Copam Middle East (FZC) Tel. +971 6 5578-488
Service Sharjah Airport International Free Zone Fax +971 6 5578-499
P.O. Box 120709 [email protected]
Sharjah

Vietnam
Sales Ho-Chi-Minh- All sectors except for ports and offshore: Tel. +84 8 8301026
Stadt Nam Trung Co., Ltd Fax +84 8 8392223
250 Binh Duong Avenue, Thu Dau Mot Town, [email protected]
Binh Duong Province [email protected]
HCM office: 91 Tran Minh Quyen Street [email protected]
District 10, Ho Chi Minh City
Ports and offshore: Tel. +84 8 62969 609
DUC VIET INT LTD Fax +84 8 62938 842
Industrial Trading and Engineering Services [email protected]
A75/6B/12 Bach Dang Street, Ward 02,
Tan Binh District, 70000 Ho Chi Minh City
Hanoi Nam Trung Co., Ltd Tel. +84 4 37730342
R.205B Tung Duc Building Fax +84 4 37762445
22 Lang ha Street [email protected]
Dong Da District, Hanoi City

Zambia
Sales Kitwe EC Mining Limited Tel. +260 212 210 642
Plots No. 5293 & 5294,Tangaanyika Road, Off Fax +260 212 210 645
Mutentemuko Road, [email protected]
Heavy Industrial Park, http://www.ecmining.com
P.O.BOX 2337
Kitwe
19381212/EN – 03/2015

416 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Index

Index
A BP brake
Block diagram of brake control, terminal box.......
Additional documentation..................................... 11 262
Additional feature ventilation .............................. 336 Brake coil resistance..................................... 258
Ambient temperature, maximum .......................... 37 Braking contactor .......................................... 259
Approved unit combinations............................... 302 Cable routing......................................... 243, 259
Assignment table Description .................................................... 248
Cables for CMP servomotors........................ 344 Dimension drawings for brake controls......... 263
Cables to CMP servomotors with BP brake.. 350 Function ........................................................ 250
Cables to CMP servomotors with BY brake......... General information ...................................... 250
356, 358, 366, 367
Operating currents ........................................ 257
Connectors and terminal boxes .................... 316
Principle ........................................................ 249
Encoder cables for connection option KK ..... 368
Selecting the brake ....................................... 251
Encoder cables for plug connection option /KKS
Sizing .................................................... 243, 259
...................................................................... 368
Technical data............................................... 256
Power cables and plug connectors CMP ...... 324
Wiring diagram for brake control plug connector
Power cables and plug connectors for CMPZ
...................................................................... 260
motors ........................................................... 325
Working capacity in case of emergency switch-
Axial forces........................................................... 43
ing off ............................................................ 255
B BP/BK brake
B10d values ....................................................... 304 Important design information ................ 236, 252
Ball bearing combinations, approved ................... 43 brake control system
BK brake Safety-rated .................................................. 301
BK brake coil resistance ............................... 242 Brake rectifier
Block diagram of brake control, terminal box....... BME .............................................................. 293
246 BMH .............................................................. 294
Braking contactor .......................................... 243 BMK .............................................................. 295
Cable routing......................................... 243, 259 BMP .............................................................. 294
Description .................................................... 232 BMV ...................................................... 244, 260
Dimensions drawings for brake controls ....... 247 BMV for CMP50, CMP63 .............................. 246
Function ........................................................ 234 BMV for CMP71 to CMP100 ......................... 262
General information ...................................... 234 BS ......................................................... 244, 260
Operating currents ........................................ 242 BS for CMP50, CMP63 ................................. 246
Principle ........................................................ 233 BS for CMP71 to CMP100 ............................ 262
Selecting the brake ....................................... 235 BSG .............................................................. 296
Sizing .................................................... 243, 259 Direct 24 V supply................................. 245, 261
Technical data............................................... 241 Brakemotors......................................................... 16
Wiring diagram brake control plug connector ...... BST
244 Characteristic safety values .......................... 304
19381212/EN – 03/15

Working capacity in case of emergency switch- Dimension drawings...................................... 303


ing off ............................................................ 239 BST brake module ............................................. 301
Block diagram of BY brake control – plug connec- BY brake
tors ................................................................ 286
Bestimmen der Bremsenspannung;Bremsens-
Block diagram of BY brake control – terminal box .... pannung BY-Bremse..................................... 278
293

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 417


Index

Block diagram of brake control – plug connec- Connection of SM1/SB1 power plug connector -BP
tors ................................................................ 286 brake ............................................................. 327
Block diagram of brake control – terminal box..... Connection of SM1/SB1 power plug connector, BY
293 brake ............................................................. 327
Braking torques..................................... 281, 304 Connection of SMB/SBB power plug connectors -
Braking work ......................................... 281, 304 BP brake ....................................................... 327
BY(FS) .......................................................... 298 Connection of SMB/SBB power plug connectors -
BY brake ....................................................... 328
Dimension drawings BY brake control .......... 297
Connection option via terminal box .................... 331
Dimensioning and routing of the cable.......... 283
Connection variants ........................................... 316
Emergency stop features .............................. 271
Copyright notice ................................................... 12
General information ...................................... 265
Corrosion protection............................................. 19
Important design information ........................ 267
Manual brake release ................................... 282 D
Operating currents of BY brakes................... 279
Degrees of protection according to IEC 60034‑5 ......
Principle of the BY brake .............................. 265 41
Resistance brake coils .................................. 280 Derating................................................................ 38
Selecting the brake control system ............... 284 Designs, possible
Selecting the brake in accordance with the proj- Brakemotors.................................................... 16
ect planning data........................................... 266
For international markets ................................ 17
Selecting the braking contactor..................... 283
Dimension drawings
Technical data............................................... 273
BK brake controls.......................................... 247
Working capacity........................................... 270
BP brake controls.......................................... 263
C Dimension drawings BST................................... 303
Dimension drawings BY brake control ............... 297
Cable specification
Dimension sheet information CMP..................... 170
Encoder cables ............................................. 392
Documentation, additional................................. 0
Forced cooling fan cables ............................. 394
Power cables ................................................ 388 E
Characteristic safety values ............................... 312
Electrical characteristics....................................... 39
Encoders....................................................... 311
EMC measures .................................................... 29
Circuit breaker and protective equipment ............ 29
Encoder cables for CMP. servomotors .............. 380
CMP product description
Encoders ............................................................ 305
Brakemotors.................................................... 16
Safety-rated .................................................. 309
CMP synchronous servomotors...................... 13
CMPZ synchronous servomotors.................... 13
F
Features of CMP. servomotors ....................... 13 Forced cooling fan cables, CMP. servomotors .. 386
Output types of CMP motors........................... 15 Functional safety .................................................. 18
Painting ........................................................... 15 BY brake ....................................................... 298
Rated speeds.................................................. 14 Functional safety technology................................ 18
Thermal motor information with KTY ............ 313
H
Torque range .................................................. 14
19381212/EN – 03/15

Cold storage application....................................... 37 Heavy load range .............................................. 0


Conformity with directives .................................... 27 I
Conformity with standards.................................... 27
Interfaces
Connection of signal plug connectors - encoder .......
330 Absolute ................................................ 311, 312
Sine/cosine ........................................... 311, 312

418 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


Index

International markets............................................ 17 Rated data ...................................................... 28


L Thermal characteristics................................... 37
Project planning for cable cross section............. 342
Light load range ................................................ 0 Project planning notes CMP
M Project planning procedure ............................. 37
Project planning procedure .................................. 33
Manual brake release retrofit set........................ 282
Part 1, servo gear units................................... 33
Manual brake release, BY brake........................ 282
Part 2, servo gear units................................... 34
Maximum ambient temperature ........................... 37
Part 3, servomotors......................................... 35
Maximum speed................................................... 70
Part 4, servomotors......................................... 36
Mechanical characteristics ................................... 39
Motor operating temperatures.............................. 15 R
Motor protection ................................................. 313 Rated data............................................................ 28
Thermal motor protection with PTC resistor . 314 Resistances
Motor types BP-Bremsspulen ........................................... 258
Encoders....................................................... 305 Retrofit set for manual brake release ................. 282
N S
Nameplate, example ............................................ 28 Safety characteristics ......................................... 311
No-load starting frequency, BY brake ................ 277 Safety function ................................................... 298
Number of poles................................................... 14 SBA............................................................... 298
O SBH............................................................... 298
Serial number....................................................... 26
Operating currents
SEW-EURODRIVE
BP brake ....................................................... 257
Group of companies.......................................... 7
Overhung loads.................................................... 43
SEW‑EURODRIVE
P Products............................................................ 8
Performance level .............................................. 298 Systems ............................................................ 8
Plug connector connection option ...................... 322 Standard conformity ............................................. 27
Plug connectors, connection option ................... 322 Standard type
Power cables and plug connectors CMP ........... 324 Connection variants ...................................... 316
Power cables and plug connectors for CMPZ mo- Motor protection ............................................ 313
tors ................................................................ 325 Standards and regulations ................................... 27
Power cables for CMP. motors .......................... 372 Structure of prefabricated cables for CMP. servo-
Preventive measures ........................................... 29 motors ........................................................... 369
Product groups....................................................... 8 Surface protection ................................................ 19
Product names ..................................................... 12 T
Production description of BY brakes
Technical data
Basic function................................................ 265
BK brake ....................................................... 241
Project planning
BP brake ....................................................... 256
19381212/EN – 03/15

Approved ball bearing types ........................... 43


Characteristic safety values BST .................. 304
Derating for increased ambient temperature .. 38
Forced cooling fan ........................................ 337
Mechanical characteristics;Electrical character-
istics ................................................................ 39 Technical data of BY brakes
Overhung loads;Axial loads ............................ 43 Brake coil resistance..................................... 280
Product characteristics of inverters................. 69 Braking torques..................................... 281, 304

Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100 419


Index

Braking work ................................................. 281


Operating currents ........................................ 279
Technical data of CMP
Thermal motor information with KTY ............ 313
Technical data of CMP and CMPZ servomotors
CMPZ motors.................................................. 77
Technical data of the BY brake .......................... 273
Terminal box ........................................................ 22
CMP71 – CMP100 connection...................... 334
Connection of CMP50 and CMP63............... 332
Terminal box, connection option ........................ 331
Thermal characteristics ........................................ 37
Thermal motor protection ................................... 313
Trademarks .......................................................... 12
Type designation
Connection variants ........................................ 25
Encoder........................................................... 24
Mechanical attachments ................................. 24
Motor series .................................................... 24
Temperature sensor and temperature detection
........................................................................ 24
Ventilation ....................................................... 25
Type designation of a servomotor........................ 26
U
unit combinations
Approved....................................................... 302
UWU51A switched-mode power supply............. 338
V
Ventilation, additional feature............................. 336
VR forced cooling fan
Mechanical installation.................................. 336
W
Wiring diagram for RH1M resolver signal plug con-
nectors .......................................................... 329
Wiring diagrams of the brake control – BY brake –
plug connector
BME .............................................................. 286
BMH .............................................................. 288
19381212/EN – 03/15

BMK .............................................................. 289


BMKB............................................................ 290
BMP .............................................................. 287
BMV .............................................................. 291
BSG .............................................................. 292

420 Catalog – CMP40 – CMP112, CMPZ71 – CMPZ100


SEW-EURODRIVE—Driving the world

SEW-EURODRIVE GmbH & Co KG


P.O. Box 3023
76642 BRUCHSAL
GERMANY
Phone +49 7251 75-0
Fax +49 7251 75-1970
[email protected]
www.sew-eurodrive.com

You might also like