Abstract: The article describes the calibration of petroleum products provers with a
compact prover as reference (master prover), using the same fluid in the same
conditions as used in the process line.
1. Introduction
The “Brazilian Technical Regulation for Measurement of Petroleum and Natural Gas” is
in use since June 2000, and companies that transfer fluids through ducts must have their metering
systems periodically calibrated according to the rules of this Technical Regulation. In the case of
transfer of large quantities of expensive fluids, the reference metering system in the petroleum
and petrochemical is usually a prover, either ball or compact, which is installed and aligned with
a totalizing flow meter, the custody transfer meter.
The prover calibration method described in the API – MPMS - Chapter 12.2 –Part 4 –
Calculation of Base Prover Volumes by the water Draw Method, is s the water draw, which
determines its volume either by using a standard test measure or by the gravimetric method
(weighing device), using water as calibrating fluid.
To use this method is necessary to disconnect the prover from the metering station,
normally isolating the prover from the system by means of a blind plate. The system must be then
be decontaminated, i.e., all the working fluid must be drained, and washed. After that, it is
necessary to assemble a bench composed by re-circulation pumps, a reservoir with enough
potable water to fulfill the test line and a standard test measure or a weighing tank. This requires
significant time and work, which implies that this kind of test is quite expensive.
2. Methodology of Calibration
The calibration of provers using the "prover-by-prover" method consists basically in the
determination of the base prover volume using another calibrated prover as standard, and an
intermediate meter between both provers, to be calibrated by both provers and then extrapolating
the global uncertainty. This meter will be the responsible for the transference of the volume
values, as it is mentioned in the OIML R 119 - Pipe provers for testing measuring systems for
liquids other than water.
1
Copyright @ FLOMEKO 2010
15th Flow Measurement Conference (FLOMEKO) October 13-15, 2010 Taipei, Taiwan
T P
Master prover
Portable compact prover Optical
switches
Master
meter
Electronic meter
proving counter
Electronic meter
proving counter Flow reversal valve
with seal check facility Sphere
for master meter Pipe prover to be calibrated
T P D1
Vent valve
Detector Switch
supply line
T P D2
Return
line
In the tests conducted at the facilities of a petroleum refinery, a conventional ball prover with
3600 litres (prover under calibration) was calibrated with a compact prover of 94 litres (master
prover), using a 6 inches turbine meter as the transfer standard.
The mobile prover was assembled in series with the measurement station which contains the
prover to be calibrated, with all secondary instruments installed, composed of the following
items:
Flowmeter, which was a turbine meter;
Static pressure transmitter installed near the turbine meter;
Temperature transmitter, sensor installed in the turbine meter.
These instruments were connected to the flow computer of the master prover (the compact
prover). These outputs are usually installed on the flow computer assembled in the measurement
station.
2
Copyright @ FLOMEKO 2010
15th Flow Measurement Conference (FLOMEKO) October 13-15, 2010 Taipei, Taiwan
Once the mobile prover is installed, the calibration system will function as a measurement
station composed of the two provers and a turbine meter.
The calibration of the turbine (master meter) installed on the measurement station should then
take place, using both provers in each run.
The meter calibration consists on the meter factor (MF) determination and its calculation is
presented below.
Combining the volume equations of the turbine meter and prover, the mathematical model
which is used for the determination of the MF is obtained. This model is obtained from both
provers, the master prover (mp) and the prover under calibration (puc). The index p refers to any
of the provers, the index m refers to the turbine meter.
Vp15
MF
Vm15
on which:
3
Copyright @ FLOMEKO 2010
15th Flow Measurement Conference (FLOMEKO) October 13-15, 2010 Taipei, Taiwan
The “prover-by-prover” calibration method made the comparison between the results obtained
in the calibrations of the meter installed on the measurement station realized with both provers, in
the same operating conditions, and it is therefore important that the information contained on the
flow computers of both systems, be correctly configured with the same fluid specification, fluid
density, correction tables for the calculation of CTL and CPL, since these calculations are
implemented through the flow computers algorithms.
The turbine meter was calibrated realizing 5 runs for each flow rate. Two different flow rates
were used: operating flow rate and another at least 25% below this value.
The calibration of the turbine meter used as reference must take place simultaneously with
both provers installed in series. Once the meter has been calibrated and the calibration reports
from both flow computers obtained, with all corrections made, it is possible to calculate the new
volume for the prover that is being calibrated, using the volume of the master prover as reference.
As explained, it was used a turbine meter to transfer the values of the master prover volume
(compact prover used as reference) to the volume of the prover under calibration.
The MF of the turbine meter obtained using the prover under calibration must equal the MF
obtained with the master prover used as reference.
MF15 Masterprover
FC or
MF15 actual MFprover under calibratio n
And:
MF15 New MF prover under calibration MF15 actual MF prover under calibration FC (III)
4
Copyright @ FLOMEKO 2010
15th Flow Measurement Conference (FLOMEKO) October 13-15, 2010 Taipei, Taiwan
Then:
V15 New volume prover under calibration V15 actual volume prover under calibration FC
So:
V15New volume prover under calibration = new volume for the Ball prover determined on the calibration.
V15actual volume prover under calibration = volume of the ball prover used in the calibration.
4. UNCERTAINTY BUDGET
MF15 Masterprover
FC
MF15 actual MFprover under calibratio n
V15 New volume prover under calibration V15 actual volume prover under calibratio n FC
5
Copyright @ FLOMEKO 2010
15th Flow Measurement Conference (FLOMEKO) October 13-15, 2010 Taipei, Taiwan
STANDARD
u (xi) DEGREES OF PROBABILITY SENSITIVITY CONTRIBUTION
UNCERTAINTY SOURCE, Xi SIMB. ESTIMATE, xi UNCERTAINTY ci . u[Xi] [ ci . u (Xi)]2
VALUE FREEDOM DISTRIBUTION COEFICIENT , ci (%)
u(xi)
Prover volume at 15ºC (Vbasep15), in liters Vbasep15 0,0945868 u(Vbasep15) 4,7E-06 infinity Normal 10,63224 5,03E-05 2,53E-09 20,43%
Corr. for the effect of temp. on steel in a prover (CTSp) CTSp 1,0007 u(CTSp) 6,80E-05 5,885E+08 Normal 1,00493 6,83E-05 4,67E-09 37,71%
Corr. for the effect of pressure on steel prover (CPSp) CPSp 1,0000 u(CPSp) 1,57E-06 1,282E+14 Normal 1,00562 1,58E-06 2,49E-12 0,02%
Corr. for compressibility of fluid in a prover (CTLp) CTLp 0,9830 u(CTLp) 4,51E-05 2260481 Normal 1,02301 4,62E-05 2,13E-09 17,22%
Corr. For compressibility of fluid in prover (CPLp) CPLp 1,0008 u(CPLp) 2,48E-06 1,066E+10 Normal 1,00489 2,49E-06 6,21E-12 0,05%
Pulses number (Np) Np 534,6404 u(Np) 0,1691 2 Normal 0,00018 2,99E-05 8,96E-10 7,24%
K factor, pulses per unit volume (Kn) Kn 5680,000 u(Kn) 0 infinity rectangular -0,00188 0,00E+00 0 0%
Corr. for the effect of temp. on a liquid in the meter (CTLm) CTLm 0,98305 u(CTLm) 4,51E-05 1,357E+06 Normal -1,02301 -4,62E-05 2,13E-09 17,23%
Corr. for compressibility of liquid in meter (CPLm) CPLm 1,0008 u(CPLm) 3,41E-06 450 Normal -1,00489 -3,43E-06 1,18E-11 0,10%
Meter factor MF 1,0057 u(type B) 1,11E-04 381 Normal 1,00000 1,11E-04 0,000000012 9,58%
standard
MF 1,00532 3,42E-04 5,000E+00 Normal 1,00000 3,42E-04 0,000000117 90,42%
Average meter factor deviation(MF)
6 0,00036 100%
6
Copyright @ FLOMEKO 2010
15th Flow Measurement Conference (FLOMEKO) October 13-15, 2010 Taipei, Taiwan
5. RESULTS
Three different ball provers were calibrated using the method, each one with a different fluid:
Diesel oil, propane and LPG-liquefied petroleum gas, using the same compact prover as master
meter.
The results presented refer to the temperature of 15C, and 101325 Pa. Thermal volumetric
expansion coefficient of the prover´s tube (mild carbon) Gc = 3,35E-05/oC. Modulus of elasticity
of the prover´s tube material (mild carbon steel) E = 206800000 kPa.
Table 1 – Results obtained in the calibration of the ball prover using Diesel oil
The expanded uncertainty associated to the average volume is of 3,25 Liters or 0,09%
Note: The expanded uncertainty shown is based in a combined standard uncertainty multiplied
by a coverage factor k = 2,52, which gives an approximated 95% confidence level.
Table 2 – Results obtained in the calibration of the ball prover using propane
The expanded uncertainty associated to the average volume is of 0,36 Liters or 0,09%
7
Copyright @ FLOMEKO 2010
15th Flow Measurement Conference (FLOMEKO) October 13-15, 2010 Taipei, Taiwan
The expanded uncertainty associated to the average volume is of 1,70 Liters or 0,09%
6. CONCLUSION
This paper shows the possibility of applying this calibration method, and that its uncertainty is
in accordance with the exactitude levels demanded by Brazilian law. It is, though, possible to
achieve better uncertainty levels as the methodology is used and improved.
REFERENCES
[1] API – MPMS - Chapter 12.2 – Calculation of Petroleum Quantities Using Dynamics
Measurement Methods and Volumetric Correction Factors. Part 3 – Proving Reports.
[2] API – MPMS - Chapter 12.2 – Calculation of Petroleum Quantities Using Dynamics
Measurement Methods and Volumetric Correction Factors. Part 4 – Calculation of Base
Prover Volumes by the water Draw Method.
[3] ISO 7278-2 Liquid hydrocarbons - Dynamic measurement - Proving systems for volumetric
meters - Part 2: Pipe provers
[4] Regulamento Técnico de Medição de Petróleo e Gás Natural, aprovado pela Portaria
Conjunta ANP/INMETRO Nº 1 de 19 de Junho de 2 000.
[5] OIML R 119 – Pipe provers for testing measuring systems for liquids other than water