Eds-P506E Series: 4+2G-Port Gigabit Poe+ Managed Ethernet Switches With 4 Ieee 802.3Af/At Poe+ Ports

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

EDS-P506E Series

4+2G-port Gigabit PoE+ managed Ethernet switches with 4 IEEE 802.3af/at PoE+ ports

Features and Benefits


• Built-in 4 PoE+ ports support up to 60 W output per port

• Wide-range 12/24/48 VDC power inputs for flexible deployment

• Smart PoE functions for remote power device diagnosis and failure recovery

• 2 Gigabit combo ports for high-bandwidth communication

• Supports MXstudio for easy, visualized industrial network management

Certifications

Introduction
The EDS-P506E Series includes Gigabit managed PoE+ Ethernet switches that come standard with 4 10/100BaseT(X), 802.3af (PoE), and 802.3at
(PoE+)-compliant Ethernet ports, and 2 combo Gigabit Ethernet ports. The EDS-P506E Series provides up to 30 watts of power per PoE+ port in
standard mode and allows a high-power output of up to 4-pair 60 W for industrial heavy-duty PoE devices, such as weather-proof IP surveillance
cameras with wipers/heaters, high-performance wireless access points, and rugged IP phones.
The EDS-P506E Series is highly versatile, and the SFP fiber ports can transmit data up to 120 km from the device to the control center with high
EMI immunity. The Ethernet switches support a variety of management functions, including STP/RSTP, Turbo Ring, Turbo Chain, PoE power
management, PoE device auto-checking, PoE power scheduling, PoE diagnostic, IGMP, VLAN, QoS, RMON, bandwidth management, and port
mirroring. The EDS-P506E Series is designed especially for harsh outdoor applications with 4 kV surge protection to ensure uninterrupted reliability
of PoE systems.

Additional Features and Benefits


• Supports different PoE output settings (High-power 36 W and 60 W, • Port mirroring for online debugging
Force and Legacy modes) to maximize powered device • IGMP snooping and GMRP for filtering multicast traffic
compatibility • Port-based VLAN, IEEE 802.1Q VLAN, and GVRP to ease network
• Supports Smart PoE functions (PoE diagnosis, PD failure check, planning
PoE scheduling, and PoE Event Warning) to enhance PoE • QoS (IEEE 802.1p/1Q and TOS/DiffServ) to increase determinism
operational efficiency • Port Trunking for optimum bandwidth utilization
• Command line interface (CLI) for quickly configuring major • RADIUS, TACACS+, MAB Authentication, SNMPv3, IEEE 802.1x, MAC
managed functions ACL, HTTPS, SSH, and sticky MAC address to enhance network
• Supports EtherNet/IP, PROFINET, and Modbus TCP protocols for security
device management and monitoring • SNMPv1/v2c/v3 for different levels of network management
• Supports V-ON™ to ensure millisecond-level Layer2/Layer3 • Fiber Check™ provides a comprehensive fiber Digital Diagnostic
network recovery Monitoring (DDM) function and event warning on SFP fiber ports
• Turbo Ring and Turbo Chain (recovery time < 20 ms @ 250 • Bandwidth management to prevent unpredictable network status
switches),1 RSTP/STP, and MSTP for network redundancy • ABC-02-USB (Automatic Backup Configurator) for system
• Automatic warning by exception through email and relay output configuration backup/restore and firmware upgrade

1. Gigabit Ethernet recovery time < 50 ms

1 www.moxa.com
Specifications
Ethernet Interface
Combo Ports (10/100/1000BaseT(X) or 100/ 2
1000BaseSFP+) Full/Half duplex mode
Auto MDI/MDI-X connection
Auto negotiation speed

PoE Ports (10/100BaseT(X), RJ45 connector) 4


Full/Half duplex mode
Auto MDI/MDI-X connection
Auto negotiation speed

Standards IEEE 802.1D-2004 for Spanning Tree Protocol


IEEE 802.1p for Class of Service
IEEE 802.1Q for VLAN Tagging
IEEE 802.1s for Multiple Spanning Tree Protocol
IEEE 802.1w for Rapid Spanning Tree Protocol
IEEE 802.1X for authentication
IEEE 802.3 for 10BaseT
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3ad for Port Trunk with LACP
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3x for flow control
IEEE 802.3z for 1000BaseSX/LX/LHX/ZX

Ethernet Software Features


Filter 802.1Q VLAN, GMRP, GVRP, IGMP v1/v2/v3, Port-based VLAN

Industrial Protocols EtherNet/IP, Modbus TCP, PROFINET

Management Back Pressure Flow Control, BOOTP, DDM, DHCP Option 66/67/82, DHCP Server/
Client, Fiber check, Flow control, IPv4/IPv6, RARP, RMON, SMTP, SNMP Inform,
SNMPv1/v2c/v3, Syslog, Telnet, TFTP

MIB Bridge MIB, Ethernet-like MIB, MIB-II, P-BRIDGE MIB, Q-BRIDGE MIB, RMON MIB
Groups 1, 2, 3, 9, RSTP MIB

Redundancy Protocols Link Aggregation, MSTP, RSTP, STP, Turbo Chain, Turbo Ring v1/v2

Security Broadcast storm protection, HTTPS/SSL, MAC ACL, TACACS+, MAB authentication,
Sticky MAC, NTP authentication, Port Lock, RADIUS, SSH

Time Management IEEE 1588v2 PTP (software-based), NTP Server/Client, SNTP

Switch Properties
IGMP Groups 256

Jumbo Frame Size 9.6 KB

MAC Table Size 8K

Packet Buffer Size 12 Mbits

Priority Queues 4

Max. No. of VLANs 64

VLAN ID Range VID 1 to 4094

USB Interface
Storage Port USB Type A

LED Interface
LED Indicators PWR1, PWR2, STATE, FAULT, 10/100M (TP port), 10/100/1000M (Gigabit Combo port),
MSTR/HEAD, CPLR/TAIL, PoE

2 www.moxa.com
Serial Interface
Console Port USB-serial console (Type B connector)

Input/Output Interface
Digital Input Channels 1

Digital Inputs Max. input current: 8 mA


+13 to +30 V for state 1
-30 to +3 V for state 0

Alarm Contact Channels 1, Relay output with current carrying capacity of 0.5 A @ 48 VDC

Buttons Reset button

DIP Switch Configuration


Ethernet Interface Turbo Ring, Master, Coupler, Reserve

Power Parameters
Input Voltage 12/24/48 VDC, Redundant dual inputs

Operating Voltage 12 to 57 VDC (> 50 VDC for PoE+ output recommended)

Input Current 4.08 A @ 48 VDC

Max. PoE Power Output per Port 60 W

Connection 2 removable 4-contact terminal block(s)

Power Consumption (Max.) Max. 18.96 W full loading without PDs’ consumption

Total PoE Power Budget Max. 180 W for total PD's consumption @ 48 VDC input
Max. 150 W for total PD's consumption @ 24 VDC input
Max. 62 W for total PD's consumption @ 12 VDC input

Overload Current Protection Supported

Reverse Polarity Protection Supported

Physical Characteristics
Housing Metal

IP Rating IP40

Dimensions 49.1 x 135 x 116 mm (1.93 x 5.31 x 4.57 in)

Weight 910 g (2.00 lb)

Installation DIN-rail mounting, Wall mounting (with optional kit)

Environmental Limits
Operating Temperature EDS-P506E-4PoE-2GTXSFP: -10 to 60°C (14 to 140°F)
EDS-P506E-4PoE-2GTXSFP-T: -40 to 75°C (-40 to 167°F)

Storage Temperature (package included) -40 to 85°C (-40 to 185°F)

Ambient Relative Humidity 5 to 95% (non-condensing)

Standards and Certifications


Safety UL 61010-2-201, EN 61010-2-201

EMC EN 61000-6-2/-6-4

EMI CISPR 32, FCC Part 15B Class A

3 www.moxa.com
EMS IEC 61000-4-6 CS: 10 V
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV
IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
IEC 61000-4-11 DIPs
IEC 61000-4-8 PFMF

Power Substation IEEE 1613, IEC 61850-3 Edition 2.0

Railway EN 50121-4

Traffic Control NEMA TS2

Vibration IEC 60068-2-6

Bump IEC 61850-3 Edition 2.0

Freefall IEC 60068-2-31

Shock IEC 60068-2-27

MTBF
Time 755,167 hrs

Standards Telcordia (Bellcore), GB

Warranty
Warranty Period 5 years

Details See www.moxa.com/warranty

Package Contents
Device 1 x EDS-P506E Series switch

Cable 1 x USB type A male to USB type B male

Installation Kit 4 x cap, plastic, for RJ45 port


2 x cap, plastic, for SFP slot

Documentation 1 x quick installation guide


1 x product certificates of quality inspection, Simplified Chinese
1 x product notice, Simplified Chinese
1 x warranty card

Note SFP modules need to be purchased separately for use with this product.

4 www.moxa.com
Dimensions

Ordering Information
Combo Ports
PoE Ports
Model Name 10/100/1000BaseT(X) or 100/ Operating Temp.
10/100BaseT(X), RJ45 Connector
1000BaseSFP+

EDS-P506E-4PoE-2GTXSFP 2 4 -10 to 60°C

EDS-P506E-4PoE-2GTXSFP-T 2 4 -40 to 75°C

Accessories (sold separately)


Storage Kits
ABC-02-USB Configuration backup and restoration tool, firmware upgrade, and log file storage tool for managed
Ethernet switches and routers, 0 to 60°C operating temperature

ABC-02-USB-T Configuration backup and restoration tool, firmware upgrade, and log file storage tool for managed
Ethernet switches and routers, -40 to 75°C operating temperature

SFP Modules
SFP-1FELLC-T SFP module with 1 100Base single-mode with LC connector for 80 km transmission, -40 to 85°C
operating temperature

SFP-1FEMLC-T SFP module with 1 100Base multi-mode with LC connector for 4 km transmission, -40 to 85°C
operating temperature

SFP-1FESLC-T SFP module with 1 100Base single-mode with LC connector for 40 km transmission, -40 to 85°C
operating temperature

SFP-1G10ALC WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission; TX
1310 nm, RX 1550 nm, 0 to 60°C operating temperature

SFP-1G10ALC-T WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission; TX
1310 nm, RX 1550 nm, -40 to 85°C operating temperature

SFP-1G10BLC WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission; TX
1550 nm, RX 1310 nm, 0 to 60°C operating temperature

SFP-1G10BLC-T WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission; TX
1550 nm, RX 1310 nm, -40 to 85°C operating temperature

5 www.moxa.com
SFP-1G20ALC WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission; TX
1310 nm, RX 1550 nm, 0 to 60°C operating temperature

SFP-1G20ALC-T WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission; TX
1310 nm, RX 1550 nm, -40 to 85°C operating temperature

SFP-1G20BLC WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission; TX
1550 nm, RX 1310 nm, 0 to 60°C operating temperature

SFP-1G20BLC-T WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission; TX
1550 nm, RX 1310 nm, -40 to 85°C operating temperature

SFP-1G40ALC WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission; TX
1310 nm, RX 1550 nm, 0 to 60°C operating temperature

SFP-1G40ALC-T WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission; TX
1310 nm, RX 1550 nm, -40 to 85°C operating temperature

SFP-1G40BLC WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission; TX
1550 nm, RX 1310 nm, 0 to 60°C operating temperature

SFP-1G40BLC-T WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission; TX
1550 nm, RX 1310 nm, -40 to 85°C operating temperature

SFP-1GEZXLC SFP module with 1 1000BaseEZX port with LC connector for 110 km transmission, 0 to 60°C operating
temperature

SFP-1GEZXLC-120 SFP module with 1 1000BaseEZX port with LC connector for 120 km transmission, 0 to 60°C operating
temperature

SFP-1GLHLC SFP module with 1 1000BaseLH port with LC connector for 30 km transmission, 0 to 60°C operating
temperature

SFP-1GLHLC-T SFP module with 1 1000BaseLH port with LC connector for 30 km transmission, -40 to 85°C operating
temperature

SFP-1GLHXLC SFP module with 1 1000BaseLHX port with LC connector for 40 km transmission, 0 to 60°C operating
temperature

SFP-1GLHXLC-T SFP module with 1 1000BaseLHX port with LC connector for 40 km transmission, -40 to 85°C
operating temperature

SFP-1GLSXLC SFP module with 1 1000BaseLSX port with LC connector for 500 m transmission, 0 to 60°C operating
temperature

SFP-1GLSXLC-T SFP module with 1 1000BaseLSX port with LC connector for 500 m transmission, -40 to 85°C
operating temperature

SFP-1GLXLC SFP module with 1 1000BaseLX port with LC connector for 10 km transmission, 0 to 60°C operating
temperature

SFP-1GLXLC-T SFP module with 1 1000BaseLX port with LC connector for 10 km transmission, -40 to 85°C operating
temperature

SFP-1GSXLC SFP module with 1 1000BaseSX port with LC connector for 300/550 m transmission, 0 to 60°C
operating temperature

SFP-1GSXLC-T SFP module with 1 1000BaseSX port with LC connector for 300/550 m transmission, -40 to 85°C
operating temperature

SFP-1GZXLC SFP module with 1 1000BaseZX port with LC connector for 80 km transmission, 0 to 60°C operating
temperature

SFP-1GZXLC-T SFP module with 1 1000BaseZX port with LC connector for 80 km transmission, -40 to 85°C operating
temperature

Software
MXview-50 Industrial network management software with a license for 50 nodes (by IP address)

MXview-100 Industrial network management software with a license for 100 nodes (by IP address)

MXview-250 Industrial network management software with a license for 250 nodes (by IP address)

MXview-500 Industrial network management software with a license for 500 nodes (by IP address)

MXview-1000 Industrial network management software with a license for 1000 nodes (by IP address)

MXview-2000 Industrial network management software with a license for 2000 nodes (by IP address)

MXview Upgrade-50 License expansion of MXview industrial network management software by 50 nodes (by IP address)

6 www.moxa.com
© Moxa Inc. All rights reserved. Updated Feb 10, 2020.

This document and any portion thereof may not be reproduced or used in any manner whatsoever without the express written permission of
Moxa Inc. Product specifications subject to change without notice. Visit our website for the most up-to-date product information.

7 www.moxa.com

You might also like