Eds-P506E Series: 4+2G-Port Gigabit Poe+ Managed Ethernet Switches With 4 Ieee 802.3Af/At Poe+ Ports
Eds-P506E Series: 4+2G-Port Gigabit Poe+ Managed Ethernet Switches With 4 Ieee 802.3Af/At Poe+ Ports
Eds-P506E Series: 4+2G-Port Gigabit Poe+ Managed Ethernet Switches With 4 Ieee 802.3Af/At Poe+ Ports
4+2G-port Gigabit PoE+ managed Ethernet switches with 4 IEEE 802.3af/at PoE+ ports
• Smart PoE functions for remote power device diagnosis and failure recovery
Certifications
Introduction
The EDS-P506E Series includes Gigabit managed PoE+ Ethernet switches that come standard with 4 10/100BaseT(X), 802.3af (PoE), and 802.3at
(PoE+)-compliant Ethernet ports, and 2 combo Gigabit Ethernet ports. The EDS-P506E Series provides up to 30 watts of power per PoE+ port in
standard mode and allows a high-power output of up to 4-pair 60 W for industrial heavy-duty PoE devices, such as weather-proof IP surveillance
cameras with wipers/heaters, high-performance wireless access points, and rugged IP phones.
The EDS-P506E Series is highly versatile, and the SFP fiber ports can transmit data up to 120 km from the device to the control center with high
EMI immunity. The Ethernet switches support a variety of management functions, including STP/RSTP, Turbo Ring, Turbo Chain, PoE power
management, PoE device auto-checking, PoE power scheduling, PoE diagnostic, IGMP, VLAN, QoS, RMON, bandwidth management, and port
mirroring. The EDS-P506E Series is designed especially for harsh outdoor applications with 4 kV surge protection to ensure uninterrupted reliability
of PoE systems.
1 www.moxa.com
Specifications
Ethernet Interface
Combo Ports (10/100/1000BaseT(X) or 100/ 2
1000BaseSFP+) Full/Half duplex mode
Auto MDI/MDI-X connection
Auto negotiation speed
Management Back Pressure Flow Control, BOOTP, DDM, DHCP Option 66/67/82, DHCP Server/
Client, Fiber check, Flow control, IPv4/IPv6, RARP, RMON, SMTP, SNMP Inform,
SNMPv1/v2c/v3, Syslog, Telnet, TFTP
MIB Bridge MIB, Ethernet-like MIB, MIB-II, P-BRIDGE MIB, Q-BRIDGE MIB, RMON MIB
Groups 1, 2, 3, 9, RSTP MIB
Redundancy Protocols Link Aggregation, MSTP, RSTP, STP, Turbo Chain, Turbo Ring v1/v2
Security Broadcast storm protection, HTTPS/SSL, MAC ACL, TACACS+, MAB authentication,
Sticky MAC, NTP authentication, Port Lock, RADIUS, SSH
Switch Properties
IGMP Groups 256
Priority Queues 4
USB Interface
Storage Port USB Type A
LED Interface
LED Indicators PWR1, PWR2, STATE, FAULT, 10/100M (TP port), 10/100/1000M (Gigabit Combo port),
MSTR/HEAD, CPLR/TAIL, PoE
2 www.moxa.com
Serial Interface
Console Port USB-serial console (Type B connector)
Input/Output Interface
Digital Input Channels 1
Alarm Contact Channels 1, Relay output with current carrying capacity of 0.5 A @ 48 VDC
Power Parameters
Input Voltage 12/24/48 VDC, Redundant dual inputs
Power Consumption (Max.) Max. 18.96 W full loading without PDs’ consumption
Total PoE Power Budget Max. 180 W for total PD's consumption @ 48 VDC input
Max. 150 W for total PD's consumption @ 24 VDC input
Max. 62 W for total PD's consumption @ 12 VDC input
Physical Characteristics
Housing Metal
IP Rating IP40
Environmental Limits
Operating Temperature EDS-P506E-4PoE-2GTXSFP: -10 to 60°C (14 to 140°F)
EDS-P506E-4PoE-2GTXSFP-T: -40 to 75°C (-40 to 167°F)
EMC EN 61000-6-2/-6-4
3 www.moxa.com
EMS IEC 61000-4-6 CS: 10 V
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV
IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
IEC 61000-4-11 DIPs
IEC 61000-4-8 PFMF
Railway EN 50121-4
MTBF
Time 755,167 hrs
Warranty
Warranty Period 5 years
Package Contents
Device 1 x EDS-P506E Series switch
Note SFP modules need to be purchased separately for use with this product.
4 www.moxa.com
Dimensions
Ordering Information
Combo Ports
PoE Ports
Model Name 10/100/1000BaseT(X) or 100/ Operating Temp.
10/100BaseT(X), RJ45 Connector
1000BaseSFP+
ABC-02-USB-T Configuration backup and restoration tool, firmware upgrade, and log file storage tool for managed
Ethernet switches and routers, -40 to 75°C operating temperature
SFP Modules
SFP-1FELLC-T SFP module with 1 100Base single-mode with LC connector for 80 km transmission, -40 to 85°C
operating temperature
SFP-1FEMLC-T SFP module with 1 100Base multi-mode with LC connector for 4 km transmission, -40 to 85°C
operating temperature
SFP-1FESLC-T SFP module with 1 100Base single-mode with LC connector for 40 km transmission, -40 to 85°C
operating temperature
SFP-1G10ALC WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission; TX
1310 nm, RX 1550 nm, 0 to 60°C operating temperature
SFP-1G10ALC-T WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission; TX
1310 nm, RX 1550 nm, -40 to 85°C operating temperature
SFP-1G10BLC WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission; TX
1550 nm, RX 1310 nm, 0 to 60°C operating temperature
SFP-1G10BLC-T WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission; TX
1550 nm, RX 1310 nm, -40 to 85°C operating temperature
5 www.moxa.com
SFP-1G20ALC WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission; TX
1310 nm, RX 1550 nm, 0 to 60°C operating temperature
SFP-1G20ALC-T WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission; TX
1310 nm, RX 1550 nm, -40 to 85°C operating temperature
SFP-1G20BLC WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission; TX
1550 nm, RX 1310 nm, 0 to 60°C operating temperature
SFP-1G20BLC-T WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission; TX
1550 nm, RX 1310 nm, -40 to 85°C operating temperature
SFP-1G40ALC WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission; TX
1310 nm, RX 1550 nm, 0 to 60°C operating temperature
SFP-1G40ALC-T WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission; TX
1310 nm, RX 1550 nm, -40 to 85°C operating temperature
SFP-1G40BLC WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission; TX
1550 nm, RX 1310 nm, 0 to 60°C operating temperature
SFP-1G40BLC-T WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission; TX
1550 nm, RX 1310 nm, -40 to 85°C operating temperature
SFP-1GEZXLC SFP module with 1 1000BaseEZX port with LC connector for 110 km transmission, 0 to 60°C operating
temperature
SFP-1GEZXLC-120 SFP module with 1 1000BaseEZX port with LC connector for 120 km transmission, 0 to 60°C operating
temperature
SFP-1GLHLC SFP module with 1 1000BaseLH port with LC connector for 30 km transmission, 0 to 60°C operating
temperature
SFP-1GLHLC-T SFP module with 1 1000BaseLH port with LC connector for 30 km transmission, -40 to 85°C operating
temperature
SFP-1GLHXLC SFP module with 1 1000BaseLHX port with LC connector for 40 km transmission, 0 to 60°C operating
temperature
SFP-1GLHXLC-T SFP module with 1 1000BaseLHX port with LC connector for 40 km transmission, -40 to 85°C
operating temperature
SFP-1GLSXLC SFP module with 1 1000BaseLSX port with LC connector for 500 m transmission, 0 to 60°C operating
temperature
SFP-1GLSXLC-T SFP module with 1 1000BaseLSX port with LC connector for 500 m transmission, -40 to 85°C
operating temperature
SFP-1GLXLC SFP module with 1 1000BaseLX port with LC connector for 10 km transmission, 0 to 60°C operating
temperature
SFP-1GLXLC-T SFP module with 1 1000BaseLX port with LC connector for 10 km transmission, -40 to 85°C operating
temperature
SFP-1GSXLC SFP module with 1 1000BaseSX port with LC connector for 300/550 m transmission, 0 to 60°C
operating temperature
SFP-1GSXLC-T SFP module with 1 1000BaseSX port with LC connector for 300/550 m transmission, -40 to 85°C
operating temperature
SFP-1GZXLC SFP module with 1 1000BaseZX port with LC connector for 80 km transmission, 0 to 60°C operating
temperature
SFP-1GZXLC-T SFP module with 1 1000BaseZX port with LC connector for 80 km transmission, -40 to 85°C operating
temperature
Software
MXview-50 Industrial network management software with a license for 50 nodes (by IP address)
MXview-100 Industrial network management software with a license for 100 nodes (by IP address)
MXview-250 Industrial network management software with a license for 250 nodes (by IP address)
MXview-500 Industrial network management software with a license for 500 nodes (by IP address)
MXview-1000 Industrial network management software with a license for 1000 nodes (by IP address)
MXview-2000 Industrial network management software with a license for 2000 nodes (by IP address)
MXview Upgrade-50 License expansion of MXview industrial network management software by 50 nodes (by IP address)
6 www.moxa.com
© Moxa Inc. All rights reserved. Updated Feb 10, 2020.
This document and any portion thereof may not be reproduced or used in any manner whatsoever without the express written permission of
Moxa Inc. Product specifications subject to change without notice. Visit our website for the most up-to-date product information.
7 www.moxa.com