275GL Series 12V 275GL+: Gas Engine With ESM 2
275GL Series 12V 275GL+: Gas Engine With ESM 2
275GL Series 12V 275GL+: Gas Engine With ESM 2
Technical Data
Cylinders 16V
Piston
13,048 cu. in. (214 L)
displacement
10.83” x 11.81”
Bore & stroke
(275 x 300 mm)
Jacket water
100 gal. (379 L)
system capacity
Fuel pressure
45 – 60 psi (3.1 – 4.1 bar)
range
Starting system 150 psi (10.3 bar) Image is representative of engine model.
Single, closed-loop Waukesha’s proven ESM2 control integrates the following into a Directly measures NOx emissions and automatically
engine control single, closed-loop system: adjusts operating parameters to maintain desired
system • Air/Fuel Ratio Control NOx setting.
• Wastegate Control
• Turbocharger Bypass Control
• Ignition Timing
• Knock Detection
• Fault Monitoring
Best-in-class fuel More power on more fuels, including full-load from 600-1550 Btu/ft3 More power on more fuels means more profits without
flexibility and operation up to 2300 Btu/ft3. the additional costs associated with fuel treatment
skids.
High reliability with Achieves up to 40,000 hours before top-end overhaul and 80,000 With low lifecycle costs and the ability to run up to
long maintenance hours before bottom end. 5 years continuously before overhaul, the 275GL+ is
intervals the best choice for the most remote, rugged, and
demanding applications.
Performance Data
Intercooler Water Temperature 130°F (54°C) 1000 RPM
0.3 NOx 0.5 NOx
Power bhp (kWb) 3,750 (2,796)
BSFC (LHV) Btu/bhp-hr (kJ/kWh) 6,805 (10,225) 6,665 (10,014)
WKI* (before derate) 50 50
Altitude (before derate) ft (m) 4,900 (1,493) 5,700 (1,737)
NOx g/bhp-hr (mg/Nm3 @ 5% O2) 0.3 (121) 0.5 (202)
CO g/bhp-hr (mg/Nm @ 5% O2)
3
1.99 (806) 1.57 (636)
Emissions
All information provided is subject to change without notice. All technical and performance data to be released via SAA - please contact Application
Engineering.
Consult your local Waukesha gas engine representative for system application assistance. The manufacturer reserves the right to change or modify
without notice, the design or equipment specifications as herein set forth without incurring any obligation either with respect to equipment previously
sold or in the process of construction except where otherwise specifically guaranteed by the manufacturer.