High Speed Switching: Absolute Maximum Ratings
High Speed Switching: Absolute Maximum Ratings
High Speed Switching: Absolute Maximum Ratings
October 2008
FJA13009
High Speed Switching
• Suitable for Switching Regulator and Motor Control
• High Voltage Switch Mode Applications
1 TO-3P
1.Base 2.Collector 3.Emitter
* These ratings are limiting values above which the serviceability of any semiconductor device may be impaired.
V CE = 5V IC = 3 IB
hFE, DC CURRENT GAIN
1 VBE(sat)
10
0.1
VCE(sat)
1 0.01
0.1 1 10 100 0.1 1 10 100
1000 10000
VCC=125V
IC=5IB
tR, tD [ns], TURN ON TIME
Cob[pF], CAPACITANCE
100 1000
tR
1 10
0.1 1 10 100 1000 0.1 1 10 100
10000 100
VCC=125V
IC=5IB
tSTG, tF [ns], TURN OFF TIME
10
IC[A], COLLECTOR CURRENT
m
10
10 DC
0m
s
1m
tSTG
s
1000 1
0.1
tF
100 0.01
0.1 1 10 100 1 10 100 1000
Figure 5. Turn Off Time Figure 6. Forward Bias Safe Operating Area
140
100
Vcc=50V,
IB1=1A, I B2 = -1A 120
L = 1mH
10 100
80
1
60
40
0.1
20
0.01 0
10 100 1000 10000 0 25 50 75 100 125 150 175
5.00
4.60
15.80 1.65
15.40 1.45
5.20
4.80
(R0.50)
20.10
19.70 18.90
18.50
3.70
3.30
(1.85)
2.20
1.80
2.60
2.20
3.20 20.30
2.80 19.70
1.20
0.55 0.80
1 3
(R0.50)
NOTES:
A) THIS PACKAGE CONFORMS TO EIAJ
SC-65 PACKAGING STANDARD.
B) ALL DIMENSIONS ARE IN MILLIMETERS.
C) DIMENSIONING AND TOLERANCING PER
ASME14.5 1973.
D) DIMENSIONS ARE EXCLUSIVE OF BURRS,
MOLD FLASH, AND TIE BAR EXTRUSIONS.
E) DRAWING FILE NAME: TO3P03AREV2.
DISCLAIMER
FAIRCHILD SEMICONDUCTOR RESERVES THE RIGHT TO MAKE CHANGES WITHOUT FURTHER NOTICE TO ANY PRODUCTS
HEREIN TO IMPROVE RELIABILITY, FUNCTION, OR DESIGN. FAIRCHILD DOES NOT ASSUME ANY LIABILITY ARISING OUT OF
THE APPLICATION OR USE OF ANY PRODUCT OR CIRCUIT DESCRIBED HEREIN; NEITHER DOES IT CONVEY ANY LICENSE
UNDER ITS PATENT RIGHTS, NOR THE RIGHTS OF OTHERS. THESE SPECIFICATIONS DO NOT EXPAND THE TERMS OF
FAIRCHILD’S WORLDWIDE TERMS AND CONDITIONS, SPECIFICALLY THE WARRANTY THEREIN, WHICH COVERS THESE
PRODUCTS.
As used herein:
1. Life support devices or systems are devices or systems 2. A critical component is any component of a life support
which, (a) are intended for surgical implant into the body, or device or system whose failure to perform can be reasonably
(b) support or sustain life, and (c) whose failure to perform expected to cause the failure of the life support device or
when properly used in accordance with instructions for use system, or to affect its safety or effectiveness.
provided in the labeling, can be reasonably expected to result
in significant injury to the user.
Rev. I31
© 2008 Fairchild Semiconductor Corporation www.fairchildsemi.com
FJA13009 Rev. A1 5