Femap Tip and Tricks: Equation Based Loading
Femap Tip and Tricks: Equation Based Loading
Femap Tip and Tricks: Equation Based Loading
To demonstrate the creation of equation based loading we’ll use a water tank quarter model. Prior to
load application a local coordinate system positioned at the expected water level has already been
defined and the wall surfaces have been split at the corresponding level to allow a group of wetted
surfaces to be created.
Water level
The hydrostatic pressure (P) is a function of the fluid density ( ), acceleration due to gravity (g), and fluid
depth (h).
For water, and using the mm/tonnes/s consistent set of units in this model, this simplifies to:
Note that “!z” is the Femap variable that represents the depth of water in the equation.
Create a new load definition by opening the Model section in the Model Info tree and right clicking
Loads. Select New and enter a Title in the New Load Set dialog, then click OK.
Expand the Loads section of the Model Info tree and right click Load Definitions and select On Surface.
You should now select the surfaces that represent the wetted area of the model in the Entity Selection
dialog.
In the Create Loads on Surfaces dialog, select Pressure as the load type. In the Load section of the form,
enter 1. as the Pressure. In the Coord Sys box, select the local coordinate system that is positioned at the
water level (this needs to have been defined previously). In the Method section of the form, select
Variable, then click the Advanced button.
In the Advanced Load Methods dialog select Equation and enter the equation 9.79e-6*!z in the Equation
box. Click OK and OK again.
The surface load markers are now visible, but to see the actual element loads that have been created
select Model | Load | Expand in the menu.
In the Expand Geometry Loads dialog, click the Convert to Node/Elem checkbox and click OK, then Yes
in the confirmation dialog. The elemental loads are then displayed.