Code Case 2901 Nozzle S1 SL No Description Unit Value: Provided Nozzle Flange Is Safe For External Loadings

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 1

CODE CASE 2901

NOZZLE S1
SL NO DESCRIPTION UNIT VALUE
1 Internal design pressure PD barg 80.00
2 Internal design temperature T C0 80
3 Nozzle flange size Inch 2

4 Flange class selected # 600# adequate A 350 Gr. LF2

5 Flange rating as per B16.5 PR barg 96.00 96 barg


6 Static head Ps barg 0.06
7 Gasket MOC :- Double jacketed Inconel 625 + Non Asbestos Filler
8 Gasket outside diameter God mm 85.852 As per table 21 of ASME B-
9 Gasket inside diameter Gid mm 69.85 16.20
10 Axial external load F N 1485.23 151.5 Kgf
11 Maximum external longitudinal moment M L N-m 335.5 34.2 kgf-m
12 Maximum external circumferential moment MC N-m 335.5 34 kgf-m
13 Maximum external torsional moment MT N-m 470 47.9 kgf-m
14 Effective gasket width b mm 4.001
15 Gasket load reaction diameter G mm 77.851
16 Maximum external moment Mfs N-mm 474468.6502 Resultant Moment
pm N/mm2 5.121356943
MAWPReduction Pr N/mm2 0.312014977
17 MAWPReduction Peq N/mm2 5.433371919
18 MAWPReduction Peq barg 54.334
FM As per Table 1 of Code Case
18 Code Case 2901 Moment Factor - 0.5 2901

19 MAWPEXT LOAD = Min. [ PR, (PR x (1+FM)-MAWP REDUCTION)-PS barg 89.61

Provided nozzle flange is safe for external loadings

19 16 x MFS N-mm 7591498.403


20 4xFxG N-mm 462506.5629
21 PI X G3 X (PR- PD) + FM X PR N-mm 9486858.721
22 SAFE