Panel Type Case No. : Analysis & Design of Slab

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

CALCULATION SHEET

Analysis & Design of Slab


Panel Type Case No.=
fcu 25 fcd 11.33333333 0
fyk 400 fyd 347.826087
Cover [mm], c 25 Lx 0 S-1 0

b a for 2:1 b a for 1:1 Ratio calc. b a calc 0


25 35 1.10 33.97959184 Ly

Panel Name S-1 D [mm]


Depth Lx [m] Ly [m] b a calc d [mm] 180
4.9 5.4 33.97959184 144.2 170
thickness t unit weight load
Concrete slab 0.17 25 4.25 gG= 1.3
Floor finish 0.01 16 0.08 gQ= 1.6
Ceiling Plaster 0.02 23 0.46
4.5 cm Screed 0.045 23 1.04 h, m
reservior load 0.15 14 4.09 3.5
Lwall= 0 0.00
DL with
U.d. partition wall 0.00
out own
Total DL unfactored, G k = 12.63 Wt. of 8.38
Total factored DL =g G*G k= 16.41 Slab
Live Load, Q k 4 g Q*Q k= 6.40
Design load, qdes. =gG*Gk+gQ*Qk = 22.81 qck= 16.6

r values r1 r2 r3 r4 nd
0.000 0.000 0.000 0.000 4

Alpha values axs a ys a xf a yf b


0.00 0.00 0.065 0.056 0.26
Moment Mxs Mys Mxf Myf b
0.0 0.0 35.6 30.7 1000
k-value 0 0 43 40
r 0.000 0.000 0.573 0.486
As.min[sq.mm] 213 213 213 213
Ascal [sq.mm] 0.0 0.0 801.5 680.7
As.final [sq.mm] 213.0 213.0 801.5 680.7
f 10 10 10 10
deff 140 140 140 140
Bar spacing,calc. 368.7 368.7 98.0 115.4
Bar spacing,max 200 200 200 200
Final bar spacing 200.0 200.0 90.0 110.0
Bar spacing prov. 100 120 140 160

Load Transfer on Beams, unfactored Ly/Lx= 1.10


Shear coefficient bvcx bvdx bvcy bvdy
0.000 0.000 0.000 0.000
Load on Beams Rcx Rdx Rcy Rdy
Total charac. load N.A. N.A. N.A. N.A.
Live Load N.A. N.A. N.A. N.A.
Dead Load N.A. N.A. N.A. N.A.

qck =Gk + Qk
r =100 * fcd / fyd * ( 1 - ( 1 - 2 * M / ( fcd * b * d ^ 2 ) ) ^ 0.5 )
nd = is the number of discontinuous edges of a panel
0 ≤ nd ≤ 4
a yf = ( 24 + 2 * nd + 1.5 * nd^ 2 ) / 1000
a xf = b / (( 1 + r3 ) ^ 0.5 + ( 1 + r4 ) ^ 0.5 )) ^ 2 )
b =2 / 3 { 1 - Lx / Ly * ( 2 * ayf ) ^ 0.5 *( ( 1 + r1 ) ^ 0.5 + ( 1 + r2 ) ^ 0.5 )}
r1, r2, r3, r4 are the ratios of negative moment capacity at the edges 1 to 4, respectively, to the span moment capacity
in the same direction and take values of 4/3 for continuous edges or zero for discontinuous edges

Note:-N.A.-Means Not Applicable 1 -Continuous


0 -Discontinuous
CALCULATION SHEET
Analysis
Analysis & Design & Design
of Typical Slabof Slab
Panel Type Case No.= 4
fcu 25 fcd 11.33333333 0
fyk 400 fyd 347.826087
Cover [mm], c 25 Lx 1 S-5 0

b a for 2:1 b a for 1:1 Ratio calc. b a calc 1


30 40 1.04 39.65 Ly

Panel Name S-5 D [mm]


Depth Lx [m] Ly [m] b a calc d [mm] 190
6 6.21 39.65 151.3 230
thickness t unit weight load
Concrete slab 0.23 25 5.75 gG= 1.3
Floor finish 0.01 16 0.08 gQ= 1.6
Ceiling Plaster 0.02 23 0.46
4.5 cm Screed 0.045 23 1.04 h, m
Wall Load 0.15 14 3.5
Lwall= 0 0.00
DL with
U.d. partition wall 1.00
out own
Total DL unfactored, G k = 8.33 Wt. of 2.58
Total factored DL =g G*G k= 10.82 Slab
Live Load, Q k 2.5 g Q*Q k= 4.00
Design load, qdes. =gG*Gk+gQ*Qk = 14.82 qck= 10.8

r values r1 r2 r3 r4 nd
1.333 0.000 0.000 1.333 2

Alpha values axs a ys a xf a yf b


0.051 0.045 0.038 0.034 0.24
Moment Mxs Mys Mxf Myf b
27.2 24.0 20.3 18.1 1000
k-value 26 24 22 21
r 0.200 0.176 0.148 0.132
As.min[sq.mm] 288 288 288 288
Ascal [sq.mm] 401.6 353.0 296.8 264.9
As.final [sq.mm] 401.6 353.0 296.8 288.0
f 8 8 8 8
deff 201 201 201 201
Bar spacing,calc. 125.2 142.4 169.4 174.5
Bar spacing,max 200 200 200 200
Final bar spacing 120.0 140.0 160.0 170.0
Bar spacing prov. 200 200 200 200

Load Transfer on Beams, unfactored Ly/Lx= 1.04


Shear coefficient bvcx bvdx bvcy bvdy
0.414 0.276 0.400 0.260
Load on Beams Rcx Rdx Rcy Rdy
Total charac. load 26.86 17.91 25.98 16.89
Live Load 6.20 4.14 6.00 3.90
Dead Load 20.66 13.77 19.98 12.99

qck =Gk + Qk
r =100 * fcd / fyd * ( 1 - ( 1 - 2 * M / ( fcd * b * d ^ 2 ) ) ^ 0.5 )
nd = is the number of discontinuous edges of a panel
0 ≤ nd ≤ 4
a yf = ( 24 + 2 * nd + 1.5 * nd^ 2 ) / 1000
a xf = b / (( 1 + r3 ) ^ 0.5 + ( 1 + r4 ) ^ 0.5 )) ^ 2 )
b =2 / 3 { 1 - Lx / Ly * ( 2 * ayf ) ^ 0.5 *( ( 1 + r1 ) ^ 0.5 + ( 1 + r2 ) ^ 0.5 )}
r1, r2, r3, r4 are the ratios of negative moment capacity at the edges 1 to 4, respectively, to the span moment capacity
in the same direction and take values of 4/3 for continuous edges or zero for discontinuous edges

Note:-N.A.-Means Not Applicable 1 -Continuous


0 -Discontinuous
CALCULATION SHEET
Analysis
Analysis & Design & Design
of Typical Slabof Slab
Panel Type Case No.= 7
fcu 25 fcd 11.33333333 0
fyk 300 fyd 260.8695652
Cover [mm], c 15 Lx 0 S-14 0

b a for 2:1 b a for 1:1 Ratio calc. b a calc 1


30 40 1.21 37.9 Ly

Panel Name S-14 D [mm]


Depth Lx [m] Ly [m] b a calc d [mm] 120
4 4.84 37.9 89.7 150
thickness t unit weight load
Concrete slab 0.15 25 3.75 gG= 1.3
Floor finish 0.01 16 0.08 gQ= 1.6
Ceiling Plaster 0.02 23 0.46
4.5 cm Screed 0.045 23 1.04 h, m
Wall Load 0.15 14 2.91
Lwall= 5.5 2.00
DL with
U.d. partition wall 1.00
out own
Total DL unfactored, G k = 7.32 Wt. of 3.57
Total factored DL =g G*G k= 9.52 Slab
Live Load, Q k 2 g Q*Q k= 3.20
Design load, qdes. =gG*Gk+gQ*Qk = 12.72 qck= 9.3

r values r1 r2 r3 r4 nd
0.000 0.000 0.000 1.333 3

Alpha values axs a ys a xf a yf b


0.071 0.00 0.053 0.044 0.34
Moment Mxs Mys Mxf Myf b
14.4 0.0 10.8 9.0 1000
k-value 29 0 25 23
r 0.336 0.000 0.248 0.205
As.min[sq.mm] 250 250 250 250
Ascal [sq.mm] 439.8 0.0 324.9 268.3
As.final [sq.mm] 439.8 250.0 324.9 268.3
f 8 8 8 8
deff 131 131 131 131
Bar spacing,calc. 114.3 201.1 154.7 187.3
Bar spacing,max 200 200 200 200
Final bar spacing 110.0 200.0 150.0 180.0
Bar spacing prov. 200 200 200 200

Load Transfer on Beams, unfactored Ly/Lx= 1.21


Shear coefficient bvcx bvdx bvcy bvdy
0.536 0.357 0.000 0.300
Load on Beams Rcx Rdx Rcy Rdy
Total charac. load 19.97 13.31 N.A. 11.19
Live Load 4.28 2.86 N.A. 2.40
Dead Load 15.69 10.46 N.A. 8.79

qck =Gk + Qk
r =100 * fcd / fyd * ( 1 - ( 1 - 2 * M / ( fcd * b * d ^ 2 ) ) ^ 0.5 )
nd = is the number of discontinuous edges of a panel
0 ≤ nd ≤ 4
a yf = ( 24 + 2 * nd + 1.5 * nd^ 2 ) / 1000
a xf = b / (( 1 + r3 ) ^ 0.5 + ( 1 + r4 ) ^ 0.5 )) ^ 2 )
b =2 / 3 { 1 - Lx / Ly * ( 2 * ayf ) ^ 0.5 *( ( 1 + r1 ) ^ 0.5 + ( 1 + r2 ) ^ 0.5 )}
r1, r2, r3, r4 are the ratios of negative moment capacity at the edges 1 to 4, respectively, to the span moment capacity
in the same direction and take values of 4/3 for continuous edges or zero for discontinuous edges

Note:-N.A.-Means Not Applicable 1 -Continuous


0 -Discontinuous