Delivery Release SIMATIC STEP 7 Professional / Basic V15
Delivery Release SIMATIC STEP 7 Professional / Basic V15
Delivery Release SIMATIC STEP 7 Professional / Basic V15
(0)
Rate
SIMATIC STEP 7 is the world's best known and most widely used programming software in
industrial automation. SIMATIC STEP 7 (TIA Portal) is a winner thanks to innovative
engineering for both proven and new SIMATIC controllers.
You can find the latest news on additional TIA Portal products at the following site: 109752224
STEP 7 V15 includes new features for all phases of the engineering workflow.
Hardware configuration
The following new CPUs of the S7-1500 family complete the portfolio:
CPU 1518(F)-4 PN/DP MFP (multifunctional platform)
CPU 1516T(F)
Hardware recognition of real existing PROFINET IO devices: The online function
"hardware recognition" detects IO devices on the connected PROFINET subnet. You can
transfer a detected device to your project: STEP 7 inserts the IO device with all the
modules and submodules, thus saving the manual insertion of IO devices and modules
from the hardware catalog.
The "Go to device view" function enables fast navigation from the PLC tag table to the
configured input or output in the device view.
Extended alarm display with new filter functions.
Testing with breakpoints is also possible in mixed LAD/FBD blocks for SCL and STL
programs.
When a breakpoint is reached, the CPU goes to the "HOLD" operating state. Tags can
also be monitored and controlled when the breakpoint is reached.
This allows the STL and SCL program code to be tested step-by-step using breakpoints
in order to find and correct logical errors during program creation. This enables easy and
fast analysis of complex programs before the actual commissioning.
Language innovations
"References" provides a new type of pointer. References are typed pointers that refer to a
specific ata type. When you use references, you define the data type during the creating
of the program. ecause the data type does not have to be determined at runtime, the
program will perform better nd be more clearly structured. "Dereferencing" gives can
direct write or read access to the referenced ag without having to copy the tag beforehand
or integrate additional instructions in your program.
CPU of the S7-1500 series as of version V2.5 is required to use referencing. With STEP
7 V15, references can initially only be saved for one cycle.
Constants of the BOOL type can be used at inputs of instructions in LAD/FBD. This
facilitates the esting or "bridging" of current paths.
New instructions
You can use the "FileReadC" and "FileWriteC" instructions to read data from an ASCII
file on the SIMATIC memory card on S7-1500 CPUs or write data to an ASCII file on
the SIMATIC Memory Card.
You can use the "GetClockStatus" instruction to read the following information from the
CPU-internal clock on S7-1500 CPUs:
o Information about time synchronization via an NTP Server
o Information about whether automatic switching of daylight saving to standard
time is activated
With the help of the "EQ_TypeOfDB" instruction (SCL: "TypeofDB"), the data type of a
data block which is addressed via a DB_ANY tag can be determined.
The existing "SCATTER" and "GATHER" instructions have been extended and now also
support an anonymous STRUCT data type and PLC data types with Boolean elements
only.
There are two new PID auxiliary functions available: They reduce the programming
effort for Tasks in control technology.
o "SplitRange"
o "RampFunction"
This limits the sweep rate and the maximum values of signals. The slew rate can
be individually limited in four operating areas: For positive or negative signals,
for rising or falling signals.
System functions
The information system offers the possibility to display hardware manuals integrated.
This has the advantage that you can search, filter or use the content as a favorite. Some
hardware manuals are already included in the installation of the TIA Portal V15. If
necessary, you can download additional hardware manuals available as support packages.
To do this, select the function "Check for updates" in the toolbar of the table of Contents.
Local user and rights management
o Managing project users
o Open new function rights as read only / open project as read only + write / create
users and roles
o Managing project roles
o Assignment of users to project roles
o A block for industrial security with TIA Portal
o Efficient user administration for products in a TIA Portal project
Libraries
Global libraries can be exported as read-only libraries. The contained library types have
permanent write protection and are therefore protected against changes. Write protection
of the library types is retained even when they are used as a type instance. Write
protection of protected global libraries cannot be revoked. Read-only libraries are
available for PLC and HMI types.
Boolean operands can be controlled by double-clicking on the monitor value. The actual
values can be toggled easily and quickly.
Non-Boolean operands can also be controlled easily and quickly via the stored dialog.
Both global tags and instance tags are supported in the DB.
User-defined "Instruction" type filters enable you to display all the instructions used in a
CPU in the cross-references with the respective instruction Versions.
PLC tag tables can be uploaded to and downloaded from the device in the specified
structure and enable improved team engineering on the CPU.
The PLC tag tables on the CPU are also displayed with "Accessible devices" and on the
memory card.
The online/offline comparison gives you a detailed overview of the tags available online
and offline in the individual PLC tag tables.
S7-PLCSIM
Know-how protected blocks of an S7-1500 CPU can be simulated with PLCSIM V15
(S7-1200 CPUs are currently not supported).
Using a slider for analog values and pushbuttons for Boolean values, you can very easily
make changes to values within the SIM table for quick testing of the STEP 7 user
program.
PLCSIM V15 and PLCSIM Advanced V2.0 can be installed on the same PC.
Simultaneous use of both simulation tools is excluded, however.
Trace
Generation of virtual signals based on mathematical functions from the recorded signals.
The following functions are supported:
o Basic arithmetic
o Absolute value, square root, square, 1/x, modulo operation
o Integral, differentiation
o Filter function
Calculation of the mean, RMS and integral of the selected signal in the range of the
measurement cursors
Time tags of type TIME, LTIME, TOD, LTOD, DATE and LDT can be recorded as a
signal and used to specify trigger conditions
Import and export of superimposed measurements
Moving the measurement cursors using the arrow keys
Editions
System requirements
The following table lists the recommended hardware and software requirements
Hardware/Software Requirement
Processor Intel® Core™ i5-6440EQ (up to 3.4 GHz)
RAM 16 GB (min. 8 GB, 32 GB for large projects)
Hard disc SSD with 50 GB of free space
Monitor 15.6" Full HD Display (1920 x 1080 or more)
Windows 7 (64-bit)
Operating system
Windows 7 Home Premium SP1 *
Windows 7 Professional SP1
Hardware/Software Requirement
Windows 7 Enterprise SP1
Windows 7 Ultimate SP1
Windows 10 (64-bit)
Installation
The Compatibility Tool is a function provided by the Industry Online Support with which you
can select compatible software products or check the compatibility of existing configurations.
You can find the Compatibility Tool here: 64847781
Projects can be upgraded directly to V15 from the TIA Portal project version V13 SP1. Upgrade
from earlier project versions (V11 ... V13) is based on the TIA Portal products (eg STEP 7) used
in the project in version V13 SP1 or V13 SP2 (last update recommended).
Important note
TIA Portal project versions V13 SP1 .. V14 SP1 are upgraded to the project version V15 with
TIA Portal V15. If you have to use a TIA Portal project version V13 SP1 .. V14 SP1, we
recommend an additional installation of the corresponding software in parallel to TIA Portal
V15. The license acquired for V15 is valid for all older TIA Portal Versions.
Program code and hardware configuration from STEP 7 V5.4 SP5 can be migrated directly to a
TIA Portal V15 project with STEP 7 V15.
Virus scanners
o Symantec Endpoint Protection 14
o Trend Micro OfficeScan Corporate Edition 12.0
o McAfee VirusScan Enterprise 8.8
o Kaspersky Anti-Virus 2017
o Windows Defender
o Qihoo 360 "Safe Guard 11.0" + "Virus Scanner 5.0"
Encryption Software
o Microsoft Bitlocker
Host-based Intrusion Detection System
o McAfee Application Control 8.0
Ordering data
The products with article numbers (order numbers) are listed in the attached file.
Please note
Download products are immediately available for download from the delivery release. The
package versions will be put on stock from January 2018.
All automation software updates on the day of publication, available complete for all
applications and independent of location - worldwide! Make the switch to the Software Update
Service (SUS) as download now. You can find more information here
The offer is valid for 8 weeks after delivery release of TIA Portal V15.
The SUS transition offer is available to all customers who order one of the SUS
download products listed above after delivery release of TIA Portal V15.
The offer is only valid for the delivery type SUS download.
You will receive a new SUS initial delivery (CoC, Certificate of Contract) and within 24
hours an additional free SUS delivery with the V15 upgrade as download.
Requirement: You have the current basic product with SUS capability.
You can find additional information for the SUS grace period offer in the following document:
Trial-Software Download
Here you can download a trial version for SIMATIC STEP 7 Basic and Professional V15 and
test it for 21 days (available from 22.12.2017): 109752566
Readme file
You can find additional information on STEP 7 V15 and WinCC V15 in the attached Readme
file.
Informational material
Title Link
Online Support - Technical information on the
65601780
TIA Portal
Programming Guideline for S7-1200 / S7-1500 67582299