33.2.27A AOAC of Fi Cial Method 2000.18 Fat Con Tent of Raw and Pas Teur Ized Whole Milk
33.2.27A AOAC of Fi Cial Method 2000.18 Fat Con Tent of Raw and Pas Teur Ized Whole Milk
33.2.27A AOAC of Fi Cial Method 2000.18 Fat Con Tent of Raw and Pas Teur Ized Whole Milk
a
Table 2000.18A. Interlaboratory study results for percent fat in milk (g/100 g) determined by Gerber by weight method
Sample ID Mean No. of labs sr sR RSDr, % RSDR, % r R HorRat
Raw 4.431 10–11 0.023 0.053 0.52 1.20 0.065 0.148 0.38
Pasteurized, homogenized 3.677 10–11 0.029 0.040 0.78 1.08 0.080 0.111 0.33
a
Mean based on analysis of 7 raw whole milk and 4 pasteurized homogenized whole milk, respectively. Standard deviations (sr, sR) and prediction values (r, R)
based on analyses of 8 raw milks (2 in blind duplicates) and 8 pasteurized homogenized milks (2 in blind duplicates), for a total of 200 tests. Of the total of 200
tests, statistical outliers were identified for 5 raw milk tests and 5 pasteurized homogenized milk tests. Relative standard deviations (RSDr, RSDR) were
calculated as (sr/mean) ´ 100 and (sR/mean) ´ 100, respectively.
When loaded, the centrifuge must produce, within 2 min, a butyrometer, adding milk slowly at first to prevent charring and
relative centrifugal acceleration of 350 ± 50 ´ g at the outer end of violent reaction with acid. Add 1 ± 0.05 mL isoamyl alcohol to
the butyrometer stop per. This ac cel er a tion is pro duced by butyrometer containing test portion. Insert lock stopper securely
centrifuges with the following effective radius (horizontal distance using hand-held key. Wearing insulated gloves, grasp butyrometer
between the center of the centrifuge spindle and the outer end of the at graduated neck with stoppered end up. Without allowing small
buty rometer stop per) op er ated at the speed in di cated bulb to empty, shake until all traces of curd disappear. Holding
(Table 2000.18B). butyrometer by both stoppered end and graduated neck, invert at
(e) Water bath for test butyrometers.—With thermometer, device least 4 times to mix acid remaining in the small bulb and graduated
to maintain temperature of fat column at 60°–63°C, and providing neck with the contents of larger bulb.
intermittent or constant agitation. Depth of water bath must permit
vertical immersion of butyrometer to terminal (small) bulb. Place butyrometers in centrifuge, small bulb pointing up, and
(f) Wa ter bath for tem per ing milk test samples prior to counterbalance. Centrifuge 4 min after proper speed is reached.
weighing.—With thermometer and device to maintain temperature Transfer butyrometers to water bath maintained at 60°–63°C and
of milk at 39° ± 1°C. immerse, leav ing only small bulb ex posed. Let fat col umn
(g) Analytical balance.—Weighing to nearest 0.01 g. Check equilibrate for ³5 min.
accuracy periodically and whenever balance is moved or cleaned.
Keep record of balance calibration checks. Remove one butyrometer from water bath and wipe dry. Apply
(h) Calibration weights.—Class S, standard calibration weights gentle pressure to lock stopper to bring bottom line of fat column
to verify balance accuracy within weight range to be used for upward to coincide with nearest whole percentage graduation mark.
weighing empty milk butyrometers and butyrometers containing Promptly read scale at bottom of upper meniscus to nearest 0.05%.
test portions.
(i) Reading light.—As background when measuring fat columns.
Light should be diffused (soft white) and provide illumination from E. Repeat Analysis
angles above and below level of fat column and at eye level.
Magnification device to aid reading is useful. Repeat analysis if fat column is turbid or dark in color, or if there is
white or black material at bottom of fat column. Acceptable fat
D. Determination
columns are pale to strong yellow and uniform throughout with no
(a) Preparation of milk test samples.—Place milk test sample in light or dark particles.
water bath maintained at 39° ± 1°C. Level of H2O should be at or
above milk level. Mix milk 10´ by inversion. If fat line remains on
F. Calculations
inside surface of container, run hot tap water (ca 50°–60°C) over
outside surface for 15–20 s. Mix thoroughly by inversion and weigh Calculate % (w/w) fat content in milk as follows:
test portion immediately. Do not allow milk to remain in water bath
more than 15 min after reaching 38°C.
(b) Testing.—Add 10.0 ± 0.2 mL of H2SO4 at 15°–21°C to Fat, % =
butyrometer. Tare butyrometer containing H2SO4 on analytical reading at upper meniscus – reading at lower meniscus
balance. Weigh 11.13 ± 0.03 g tempered milk test sample, D(a), into
Reference: J. AOAC Int. 84, 1499(2001).