Duty Load (kg) 250, 320, 450 550, 630, 800, 1000
Rated Speed (m/s) 0.63/1.0 1.0/1.5/1.75
Max. Rise (m) 30 90
Max. Group Control 4
Machine Type PM Gearless
Drive VVVF
Time
Saving
C-ES1
VIL-EM1C
C-EL1
CBM-EM1C
C-EL2
■ Hairline ■ Handrail
HR-04
HR-02
■ Color
0WFSIFBE ,
$)
$)
3JTF 3
1.75 800
7 550 2S 1100 1300 1850 1750
8 630 1100 1400 1850 1850
10 800 900 1200 1500 1950 1950
13 1000 1100 2100 1850 2550
Full Collective All registered car & hall calls will be answered in the sequence by which the elevator cars approach landings. The travel
●
Operation direction of car will be determined by the first registered car or hall call.
Inspection operation switches, inspection buttons & emergency stop device are provided at car top. When inspection mode
Top of Car Inspection ●
starts, only inspection operation is allowed.
Emergency Car Light When the normal lighting power fails, the emergency lighting operates. ●
Separate Car and Hall
The time of door retaining open for answering hall call and car call can be adjusted separately. ●
Call Door Times
When a car is loaded to a preset percentage of its rated load, it is considered as “full”, the car will bypass further hall calls.
Load Non Stop ●
The hall calls will be registered and will be answered on next trip (single) or by another car (group).
When elevator stays at independent service, which has been designed to meet special needs of customers, it will no longer
Independent Service ●
answer calls from out of hoistway but only operate, close & open door under manual control.
When the car is overloaded, the alarm light and buzzer operate. When overloading is indicated, car door will not close and
Overload Warning ●
elevator will not operate.
Trip Counter A counter is arranged in elevator control cabinet to count times of elevator operation for the convenience of maintenance. ●
Alarm Bell For passengers to press alarming button in emergency cases to inform outside in time. ●
Light Curtain Light curtain is provided as door closing safety device. ●
Intercom Intercom between surveillance room and machine room and car (including car top/pit) is offered, effective at power failure. ●
Emergency Firemen When fireman switch is on, the system will cancel all calls, drive elevators to fire-fighting floor directly, opens door to release
●
Operation passengers and stop operation.
Emergency Rescue in
When elevator encounters problem, the emergency rescue in controller is operated to rescue the passengers. ●
Controller
Each elevator will have a key switch 'PKS' at a designated landing (e.g., at the lobby). With this feature, a particular car may
Parking Operation ○
be commanded by its key switch to the designated landing.
Attendant Service The Attendant Operation feature allows semi-automatic operation with manual control. ○
Stopping errors shall be corrected by relevelling. The size of a possible stopping error depends on the type of drive and the
Relevelling Operation ○
accuracy of the position sensors.
Fan Automatic and A manual switch for light power is provided on car operation panel. The fan is controlled by software according to running
○
Light Manual Switch status of the elevator.
A chime installed on car top will ring when the car approaches landing to remind passengers that they have arrived at the
Chime in Car ○
destination floor.
When the car arrives at floor or ready to move, the system will announce about the floor number and running direction by
Voice Synthesizer ○
artificial voice.
If there is only one passenger in the car and an excessive number of car calls is registered, such nuisance is detected and all
Anti-Nuisance ○
car calls will be canceled, requiring registration of a proper number of calls.
Fire Alarm Home
When fire alarm system in a building is activated, the car will return to appointed floor immediately and send such signal to passengers. ○
Landing
Card Reader Passengers with IC card will be permitted to reach appointed floor. ○
By using a contact the elevator signal such as floor, up-down, fault, over-load, fire alarm etc. will be sent to costumed
BA Interface ○
Building Automation room.
Elevator Supervisory Monitor panel will be provided, and the elevator operation situation (running, overload, door opening, fire alarm, fault) will be
○
Panel monitored.
Elevator Monitor
To monitor the elevator operation, including floor, running direction, door opening. overload, fire alarm, fault by PC system. ○
System With PC
Automatic Emergency When the power fails suddenly, if the elevator has not arrived at the appointed floor, the ARED device will activate the car to
○
Rescue Device reach nearest floor and open the door; if the car has already arrived at the floor, the door will open by ARED.