BT139X800

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

NTE56058 thru NTE56060

TRIAC, 16A

Description:
The NTE56058 through NTE56060 are glass passivated TRIACs in an isolated full–pack type package
designed for use in applications requiring high bidirectional transient and blocking voltage capability and
high thermal cycling performance. Typical applications include motor control, industrial and domestic
lighting, heating and static switching.

Absolute Maximum Ratings:


Repetitive Peak Off–Sate Voltage, VDRM
NTE56058 (Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500V
NTE56059 (Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 600V
NTE56060 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 800V
RMS On–State Current (Full Sine Wave, THS ≤ 38°C), IT(RMS) . . . . . . . . . . . . . . . . . . . . . . . . . . 16A
Non–Repetitive Peak On–State Current, ITSM
(Full Sine Wave, TJ = +125°C prior to Surge, with Reapplied VDRMmax)
t = 20ms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140A
t = 16.7ms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150A
I t for Fusing (t = 10ms), I2t . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98A2sec
2

Repetitive Rate–of–Rise of On–State Current after Triggering, dIT/dt


(ITM = 20A, IG = 0.2A, dIG/dt = 0.2A/µs)
MT2 (+), G (+) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50A/µs
MT2 (+), G (–) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50A/µs
MT2 (–), G (–) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50A/µs
MT2 (–), G (+) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10A/µs
Peak Gate Current, IGM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2A
Peak Gate Voltage, VGM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5V
Peak Gate Power, PGM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5W
Average Gate Power (Over Any 20ms Period), PG(AV) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500mW
Operating Junction Temperature, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +125°C
Storage Temperature Range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –40° to +150°C
Thermal Resistance, Junction–to–Heatsink (Full or Half Cycle), RthJHS
With Heatsink Compound . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.0K/W
Without Heatsink Compound . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5K/W
Typical Thermal Resistance, Junction–to–Ambient, RthJA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55K/W
Note 1. Although not recommended, off–state voltages up to 800V may be applied without damage,
but the TRIAC may switch to the on–state. The rate–of–rise of current should not exceed
15A/µs.
Electrical Characteristics: (TJ = +25°C unless otherwise specfied)
Parameter Symbol Test Conditions Min Typ Max Unit
Static Characteristics
Gate Trigger Current
MT2 (+), G (+) IGT VD = 12V, IT = 0.1A – 5 35 mA
MT2 (+), G (–) – 8 35 mA
MT2 (–), G (–) – 10 35 mA
MT2 (–), G (+) – 22 70 mA
Latching Current
MT2 (+), G (+) IL VD = 12V, IT = 0.1A – 7 40 mA
MT2 (+), G (–) – 20 60 mA
MT2 (–), G (–) – 8 40 mA
MT2 (–), G (+) – 10 60 mA
Holding Current IH VD = 12V, IT = 0.1A – 6 30 mA
On–State Voltage VT IT = 20A – 1.2 1.6 V
Gate Trigger Voltage VGT VD = 12V, IT = 0.1A – 0.7 1.5 V
VD = 400V, IT = 0.1A, TJ = +125°C 0.25 0.4 – V
Off–State Leakage Current ID VD = VDRMmax, TJ = +125°C – 0.1 0.5 mA
Dynamic Characteristics
Critical Rate–of–Rise of dVD/dt VDM = 67% VDRMmax, TJ = +125°C, 100 250 – V/µs
Off–State Voltage Exponential Waveform, Gate Open
Critical Rate–of–Change of dVcom/dt VDM = 400V, TJ = +95°C, ITRMS = 16A, – 20 – V/µs
Commutating Voltage dIcom/dt = 7.2A/ms, Gate Open
Gate Controlled Turn–On Time tgt ITM = 20A, VD = VDRMmax, IG = 0.1A, – 2 – µs
dIG/dt = 5A/µs
Isolation Characteristics
RMS Isolation Voltage from All VISOL R.H. ≤ 65%, Clean and Dustfree – – 1500 V
3 Pins to External Heatsink
Capacitance from T2 to CISOL f = 1MHz – 12 – pF
External Heatsink

.402 (10.2) Max .173 (4.4)


Max
.224 (5.7) Max .114 (2.9)
.122 (3.1) Max
Dia

.295
(7.5)
.669 .165
(17.0) (4.2)
Max

MT1 MT2 G

.531
(13.5)
Min

.100 (2.54) .059 (1.5) Max