3 RC Piles Cap Design With Eccentricity Example - Costas - 13 02 2014 PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Job Ref.

Three Reinforced Pile Cap Design, in


Project:
accordance with (BS8110:Part1:1997).

Section
GEODOMISI Ltd. - Dr. Costas Sachpazis Sheet no./rev. 1
Civil & Geotechnical Engineering
Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Foundation
Engineering & Retaining Structures. Calc. by Date Chk'd by
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 - Mobile: (+30)
13/02/2014 Date App'd by Date
6936425722 & (+44) 7585939944, [email protected] Dr. C. Sachpazis Marcin Dajczak

RC PILE CAP DESIGN (BS8110:PART1:1997)

w2

e φ e
3 Pile Cap, height h

P1
Loaded width - y,x
Ldiag

ex
0.866s s s
L

x
P2 P3
0.288s
w1 s w1

Pile Cap Design – Truss Method


Design Input - 3 Piles - No Eccentricity
Number of piles; N=3
ULS axial load; Fuls = 1500.0 kN
The ultimate load per pile is; Fuls_pile = Fuls/3 = 500.0 kN
Characteristic axial load; Fchar = 1000.0 kN

1
Job Ref.
Three Reinforced Pile Cap Design, in
Project:
accordance with (BS8110:Part1:1997).

Section
GEODOMISI Ltd. - Dr. Costas Sachpazis Sheet no./rev. 1
Civil & Geotechnical Engineering
Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Foundation
Engineering & Retaining Structures. Calc. by Date Chk'd by
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 - Mobile: (+30)
13/02/2014 Date App'd by Date
6936425722 & (+44) 7585939944, [email protected] Dr. C. Sachpazis Marcin Dajczak

The characteristic load per pile is; Fchar_pile = Fchar/3 = 333.3 kN


Pile diameter; φ = 250 mm
Pile spacing; s = 750 mm
Pile cap overhang; e = 150 mm
Overall length of pile cap; L = sin(60) × s+ φ +2 × e = 1200 mm
Overall width of pile cap; b = s + φ +2 × e = 1300 mm
Width at pile parallel to length, L; w1 = φ + 2 × e = 550 mm
Width at pile parallel to overall width, b; w2 = φ + 2 × e = 550 mm
Overall height of pile cap; h = 450 mm
2 2
Diagonal length of sides; Lside_diag = √( (L-w1) + ((b-w2)/2) ) = 750 mm
Dimensions of loaded area; x = 300 mm
y = 300 mm
Cover
2
Concrete grade; fcu = 40.0 N/mm
Nominal cover; cnom = 40 mm
Tension bar diameter; Dt = 16 mm
Link bar diameter; Ldia = 12 mm
Depth to tension steel; d = h – cnom - Ldia - Dt/2 = 390 mm
Pile Cap Forces
Compression within pile cap; Fc = Fuls/(3 × sin(θ)) = 747.1 kN
Tension within pile cap; Ft = Fc × cos(θ) / (2 × Cos(30)) = 320.5 kN
Compression In Pile Cap - Suggested Additional Check
Check compression diagonal as an unreinforced column, using a core equivalent to pile diameter
2
Compressive force in pile cap; Pc = 0.4 × fcu × π × φ /4 = 785.4 kN
PASS Compression
Cl. 3.8.4.3

Tension In One Truss Member


2
Characteristic strength of reinforcement; fy = 500 N/mm
Partial safety factor for strength of steel; γms = 1.15
2
Required area of reinforcement; As_req = Ft /(1/γms × fy) =737 mm
2
Provided area of reinforcement; As_prov = Ast = 1005 mm
Tension in truss member; Pt = (1/γms × fy) × As_prov = 437.1 kN
PASS Tension
Cl. 3.11.4.2

Max / Min Areas of Reinforcement - Considering A Strip Of Cap


2
Minimum required area of steel; Ast_min = kt × Ac = 293 mm
2
Maximum allowable area of steel; Ast_max = 4 % × Ac = 9000 mm
Area of tension steel provided OK
Cl. 3.12.6 & Table 3.25

2
Job Ref.
Three Reinforced Pile Cap Design, in
Project:
accordance with (BS8110:Part1:1997).

Section
GEODOMISI Ltd. - Dr. Costas Sachpazis Sheet no./rev. 1
Civil & Geotechnical Engineering
Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Foundation
Engineering & Retaining Structures. Calc. by Date Chk'd by
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 - Mobile: (+30)
13/02/2014 Date App'd by Date
6936425722 & (+44) 7585939944, [email protected] Dr. C. Sachpazis Marcin Dajczak

Beam Shear

Check shear stress on the sections at distance φ / 5 inside face of piles.


Cl. 3.11.4.3 & fig. 3.23

Applied shear stress


Applied shear force; V = Fuls / 3 = 500.0 kN
Min effective width of pile cap along plane of shear; bv = min( bv1 , bv2 , 3 × φ ) = 750 mm
2
Design shear stress; v = V / ( bv × d ) = 1.71 N/mm
1/2 2
Allowable shear stress; vallowable = min ((0.8 N /mm) × √(fcu ), 5 N/mm ) =
2
5.00 N/mm
Shear stress - OK
Cl. 3.4.5.2

Design concrete shear strength


From BS8110-1:1997 Table 3.8;
1/3 1/4 2 2
vc_25 = 0.79 × r × max(0.67, (400 mm/d) ) × 1.0 N/mm / 1.25 = 0.56 N/mm
2 2 1/3
Shear enhancement (Cl. 3.4.5.8 and fig. 3.5); vc = vc_25 × ( min( fcu, 40 N/mm ) / 25 N/mm ) =
2
0.66 N/mm
av = min(2 × d, max((s / sqrt(3) - φ / 2 + φ / 5 - x / 2),
0.1mm)) = 208 mm
2
Enhanced shear stress; vc_enh = min( vallowable , 2 × d × vc / av) = 2.46 N/mm
Concrete shear strength - OK, no links reqd.
Table 3.16
Note: If no links are provided, the bond strengths for PLAIN bars must be used in calculations for
anchorage and lap lengths.
Cl. 3.12.8.3

Local Shear At Concentrated Loads (Cl 3.7.7)


Total length of inner perim. at edge of loaded area; u0 = 2 × ( x + y ) =1200 mm
Assumed average depth to tension steel; dav = d - Dt = 374 mm
Max shear effective across perimeter; Vp = Fuls = 1500.0 kN
2
Stress around loaded area; vmax = Vp / (u0 × dav) = 3.34 N/mm
1/2 2
Allowable shear stress; vallowable = min((0.8 N /mm) × √(fcu ), 5 N/mm ) =
2
5.00 N/mm
Shear stress - OK
Cl. 3.4.5.2

Clear Distance Between Bars In Tension (Cl 3.12.11.2.4)


Maximum / Minimum allowable clear distances between tension bars considering a strip of cap
Actual bar spacing;
spacingbars = max( 0mm, (bccs - nsurfaces × (cadopt + Ldia) - Dt)/(Lnt - 1) - Dt) =92 mm
Maximum allowable spacing of bars; spacingmax = min((47000 N/mm)/fs, 300 mm) = 192
mm
Minimum required spacing of bars; spacingmin = hagg + 5 mm = 25 mm

3
Job Ref.
Three Reinforced Pile Cap Design, in
Project:
accordance with (BS8110:Part1:1997).

Section
GEODOMISI Ltd. - Dr. Costas Sachpazis Sheet no./rev. 1
Civil & Geotechnical Engineering
Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Foundation
Engineering & Retaining Structures. Calc. by Date Chk'd by
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 - Mobile: (+30)
13/02/2014 Date App'd by Date
6936425722 & (+44) 7585939944, [email protected] Dr. C. Sachpazis Marcin Dajczak

Bar spacing OK
Clear Distance Between Face Of Beam And Tension Bars (Cl 3.12.11.2.5)
Distance to face of beam; Distedge = cadopt + Ldia + Dt/2 = 60 mm
2
Design service stress in reinforcement; fs = 2 × fy × As_req /(3 × As_prov × βb) = 244.4 N/mm
Max allowable clear spacing; Spacingmax = min((47000 N/mm)/fs, 300 mm) = 192
mm
Max distance to face of beam; Distmax = Spacingmax /2 = 96 mm
Max distance to beam edge check - OK
Anchorage Of Tension Steel
Anchorage factor; φfactor =35
Type of lap length; lap_type ="tens_lap"
Type of reinforcement; reft_type = "def2_fy500"
Minimum radius; rbar = 32 mm
Minimum end projection; Pbar = 130 mm
Minimum anchorage length or lap length req’d; Ltable 3.27 = φfactor × Dt = 560 mm
Check anchorage length to cl. 3.12.9.4 (b); Lcl. 3.12.9.4 = 12 × Dt + d/2 = 387 mm
Required minimum effective anchorage length; La = max(Ltable 3.27, Lcl. 3.12.9.4) = 560 mm
Check minimum radius required on bend
Note that the bars must extend at least 4D past the bend
Force per bar at bend; Fbt = Ft / Lnt = 64.1 kN
Edge bar centres; sext = cadopt + Dt = 56 mm
Edge maximum allowable bearing stress; fbt_max_ext = 2 × fcu / ( 1 + 2×(Dt / sext )) = 50.91
2
N/mm
Internal bar centres; sint = spacingbars + Dt = 108 mm
Internal maximum allowable bearing stress; fbt_max_int = 2 × fcu / ( 1 + 2×(Dt / sint )) = 61.71
2
N/mm
2
Design max allowable bearing stress; fbt_max = min(fbt_max_ext, fbt_max_int) = 50.91 N/mm
Minimum radius required; rmin = max(rbar, Fbt /(fbt_max × Dt)) = 78.7 mm
Minimum radius of bend required = 79 mm