MIPP-MODULAR-INDUSTRIAL-PATCH-PANEL PB00187 INET HIR 1019 ENG LowRes Original 146320

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Product Bulletin

Modular Industrial Patch


Panel - MIPP Key Features
• High port density: up to 72 fibers
Combines both copper and fiber cable and 24 copper cables
• LC, SC, ST and E-2000 fiber duplex
termination in one future-proof solution adapters
• Support singlemode and multimode
The MIPP is designed for harsh environments, fibers
• Double fiber module accommodates
where its robust construction and high port hybrid fiber cables
density with multiple connector types make it • RJ45 copper keystone jacks (shielded
and unshielded, CAT5E, CAT6, CAT6A)
ideal for installation in industrial networks.
• RJ45 copper coupler (shielded and
unshielded, CAT6A)
• RJ45 copper Industrial REVConnect
Maximum system flexibility & versatility by combining jacks (shielded and unshielded, CAT6A)
copper and fiber management in one patch panel. • RJ45 copper Industrial REVConnect
couplers (unshielded, CAT6A)
Highest level of reliability due to its solid metal • Module can be removed from
construction, designed for use in indoors industrial housing for easy cable installation
environments without a cabinet. • 100% factory tested pre-terminated
MPO cassette for fast, reliable fiber
installation
Quick and easy installation of structured cabling to • Wide temperature range from -20 °C
reduce installation costs (CapEx) and maintenance to +70 °C
costs (OpEx). • UL approval (UL 1863)

Due to their compact dimensions, up to 6 modules can be combined in any


permutation – and when required, each module can be easily removed or replaced.
MIPP: A Versatile, Modular Patch Panel for Industrial Applications
The MIPP provides the ideal connection between Belden cables and Hirschmann
switches. Its industrial modular design is suitable for industrial applications where
active devices or end devices must be connected to infrastructure cabling.

It can easily be mounted on a DIN Rail, or attached at the sides of the cabinets by
simply using a wall mount plate.

The MIPP Pre-Terminated MPO Cassette is 100% tested during manufacture.


No need to splice, cleave or polish when installing on the plant floor.

The MIPP is available as both single and double modules:


• Single Fiber Modules (up to 12 fiber connections)
– 6 x SC duplex adapters
– 6 x LC duplex adapters
MIPP Mix – 6 x ST duplex adapters
– 6 x E-2000 duplex adapters
• Single Copper Modules
– 2 or 4 x RJ45 keystone shielded
– 2 or 4 x RJ45 keystone unshielded
– 2 or 4 x RJ45 coupler shielded
– 2 or 4 x RJ45 coupler unshielded
– 2 or 4 x RJ45 Industrial REVConnect jack shielded
– 2 or 4 x RJ45 Industrial REVConnect jack unshielded
– 2 or 4 x RJ45 Industrial REVConnect coupler unshielded
• Double Fiber Modules (up to 24 fiber connections)
– 12 x SC duplex adapters
– 12 x LC duplex adapters
Pre-Terminated
– 12 x ST duplex adapters
MPO Cassette
– 12 x E-2000 duplex adapters

Applications and Markets


The MIPP is ideal for use in a wide range of industrial applications requiring maximum
system reliability and flexibility. The industrial design makes it highly suited for use
in Machine Building, Transportation, Alternative Power Generation, Oil & Gas, and
Power Transmission & Distribution markets, as well as more general use in enterprise,
buildings and other applications.

Technical Information
Housing Type and Description
Description Modular Industrial Patch Panel, DIN Rail
Number of Single Modules 1 2 3 4 5 6

Mechanical Construction
Material Housing Aluminium
Dimensions (W x H x D) 42 x 138 x 122 mm 72 x 138 x 122 mm 102 x 138 x 122 mm 132 x 138 x 122 mm 162 x 138 x 122 mm 192 x 138 x 122 mm
Dimensions with Adapters 165 x 133 mm 165 x 133 mm 165 x 133 mm 165 x 133 mm 165 x 133 mm 165 x 133 mm
and Gland, max. (H x D)
Mounting DIN Rail
Appr. Weight Housing 360 g 530 g 697 g 865 g 1034 g 1200 g
Dimension Wallmount Plate 38 x 157 mm 68 x 157 mm 98 x 157 mm 128 x 157 mm 158 x 157 mm 188 x 157 mm
(WxH)
Appr. Weight Wallmount Plate 67 g 119 g 172 g 223 g 277 g 329 g

2 EMEA +49 (0) 7127/14 -1809 | hirschmann.com  US 1-800-BELDEN-1 | belden.com


Be Certain. Belden.

Technical Information
Module Type and Description
MIPP Fiber Splice Box MIPP Copper Patch Panel
Type Single Module Single Module Single Module Single Module Single Module Single Module
Description 6 x SC Duplex 6 x LC Duplex 6 x ST Duplex 6 x E-2000 Duplex 4 x RJ45 Keystone 4 x RJ45 Coupler,
Jack, Unshielded Unshielded

Mechanical Construction
Material Steel
Adapter/Keystone Types • Blue SC adapter OS2 •B  lue LC adapter OS2 •B  lue ST adapter OS2 • Blue E-2000 adapter • C AT5E Modular • C AT6A/10GX Modular
UPC zirconia ceramic UPC zirconia ceramic UPC zirconia ceramic OS2 UPC zirconia Jack, Keyconnect, Jack, Keyconnect
• Beige SC adapter •B  eige LC adapter •B  eige ST adapter ceramic black Couple, black
OM1/OM2 PC OM1/OM2 PC OM1/OM2 PC • Beige E-2000 adapter • C AT6+ Modular • C AT6A/10GX Industrial
phosphor bronze phosphor bronze phosphor bronze OM1/OM2 Jack, Keyconnect, REVConnect Coupler,
• Aqua SC adapter • A qua LC adapter • A qua ST adapter PC zirconia ceramic black black
OM3/OM4 PC OM3/OM4 PC OM3/OM4 PC • Aqua E-2000 adapter • C AT6A/10GX Modular
zirconia ceramic zirconia ceramic zirconia ceramic OM3/OM4 PC Jack, Keyconnect,
zirconia ceramic black
• C AT6A/10GX Industrial
REVConnect Jack,
black
Appr. Weight Module 218 g 218 g 218 g 218 g 516 g 516 g
Protection Class IP40 IP40 IP40 IP40 IP20 IP20
Cable Entry 3 x M16 Glands 3 x M16 Glands 3 x M16 Glands 3 x M16 Glands • 1 cable entry point • 1 cable entry point
• with tie wrap fixing latch • with tie wrap fixing latch
Maximum Diameter Cable 10 mm 10 mm 10 mm 10 mm 8.6 mm 8.6 mm
Cable Types Fiber cables up to 12 fibers: loose tube, mini-breakout, breakout cables CAT5E unshielded, CAT6 unshielded,
CAT6A unshielded

Module Type and Description


Type Double Modules Double Modules Double Modules Double Modules Single Module Single Module
Description 12 x SC Duplex 12 x LC Duplex 12 x ST Duplex 12 x E-2000 Duplex 4 x RJ45 Keystone 4 x RJ45 Coupler,
Jack, Shielded Shielded

Mechanical Construction
Material Steel
Adapter/Keystone Types • Blue SC adapter OS2 •B  lue LC adapter OS2 •B  lue ST adapter OS2 • Blue E-2000 adapter • CAT5E Shielded Modular • C AT6A/10GX Shielded
UPC zirconia ceramic UPC zirconia ceramic UPC zirconia ceramic OS2 UPC zirconia Jack, Keyconnect, Modular Jack,
• Beige SC adapter •B  eige LC adapter •B  eige ST adapter ceramic metal body Keyconnect Coupler,
OM1/OM2 PC OM1/OM2 PC OM1/OM2 PC • Beige E-2000 adapter • C AT6+ Shielded Modular metal body
phosphor bronze phosphor bronze phosphor bronze OM1/OM2 PC Jack, Keyconnect,
• Aqua SC adapter • A qua LC adapter • A qua ST adapter phosphor bronze metal body
OM3/OM4 PC OM3/OM4 PC OM3/OM4 PC • Aqua E-2000 adapter • C AT6A/10GX Shielded
zirconia ceramic zirconia ceramic zirconia ceramic OM3/OM4 PC Modular Jack, Keyconnect,
zirconia ceramic metal body
• C AT6A/10GX Shielded
Industrial REVConnect
Jack, metal body
Appr. Weight Module 450 g 450 g 450 g 450 g 636 g 636 g
Protection Class IP40 IP40 IP40 IP40 IP20 IP20
Cable Entry 1 x M20 Gland 1 x M20 Gland 1 x M20 Gland 1 x M20 Gland • 1 cable entry point • 1 cable entry point
2 x M16 Glands 2 x M16 Glands 2 x M16 Glands 2 x M16 Glands • with tie wrap fixing latch • with tie wrap fixing latch
Maximum Diameter Cable 13 mm for G20 13 mm for G20 13 mm for G20 13 mm for G20 8.6 mm 8.6 mm
10 mm for G16 10 mm for G16 10 mm for G16 10 mm for G16
Cable Types Fiber cables up to 24 fibers: loose tube, mini-breakout CAT5E shielded, CAT6 shielded, CAT6A shielded,
Hybrid fiber cable: 6 x SM + 6 x OM1, 6 x SM + 6 x OM2, 6 x SM + 6 x OM3, 6 x SM + 6 x OM4 CAT7 shielded
Accessories
Pigtails • SC/UPC SM 9/125, OS2 • LC/UPC SM 9/125, OS2 • ST/UPC SM 9/125, OS2 • E-2000/UPC SM 9/125, OS2 • Universal cable crimping • Universal cable crimping
(1 pack of 12 pigtails, • SC/PC MM 62.5/125, OM1 • L C/PC MM 62.5/125, OM1 • S T/PC MM 62.5/125, OM1 • E-2000/PC MM 62.5/125, OM1 tool tool
900 micron, 0.6 m in • SC/PC MM 50/125, OM2 • L C/PC MM 50/125, OM2 • S T/PC MM 50/125, OM2 • E-2000/PC MM 50/125, OM2 • Core pack 10 pcs • Core pack 10 pcs
12 different colours) • SC/PC MM 50/125, OM3 • L C/PC MM 50/125, OM3 • S T/PC MM 50/125, OM3 • E-2000/PC MM 50/125, OM3 • Core Pack 20 pcs • Core Pack 20 pcs
• SC/PC MM 50/125, OM4 • L C/PC MM 50/125, OM4 • S T/PC MM 50/125, OM4 • E-2000/PC MM 50/125, OM4 • Core Pack 50 pcs • Core Pack 50 pcs
For MIPP housings equipped For MIPP housings equipped
with Industrial RevConnect with Industrial RevConnect
jacks or couplers jacks or couplers
Brilliance Field Installable 12 brilliance connectors SC: 12 brilliance connectors LC: 24 brilliance connectors ST:
Connector • SM 9/125, OS2, blue • SM 9/125, OS2, blue • SM 9/125, OS2, blue
(900 micron) • MM 62.5/125, OM1, • MM 62.5 micron, OM1, • MM 62.5/125, OM1,
beige beige beige
• MM 50/125, OM2, • MM 50 micron, OM2, • MM 50/125, OM2,
black black black
• MM 50/125, OM3/ • MM 50 micron, OM3/ • MM 50/125, OM3/
OM4, aqua OM4, aqua OM4, aqua

EMEA +49 (0) 7127/14 -1809 | hirschmann.com  US 1-800-BELDEN-1 | belden.com 3


Be Certain. Belden.

MIPP Configurator
Please Choose your Configuration Housing Module 1 Module 2 Module 3
Code in the Designated Boxes M I P P / L D / 2 S 3 P / c u e 4 / 1 N N N
Example Module 2
Housing
c u e 4
X = No housing H = 2 x double module fiber
A = 1 x single module I = 3 x double module fiber
B = 2 x single module J = 1 x single + 1 x double fiber Copper Patch Panel Module
C = 3 x single module K = 1 x single + 2 x double fiber
D = 4 x single module L = 2 x single + 1 x double fiber c = Single copper module
E = 5 x single module M = 2 x single + 2 x double fiber
F = 6 x single module N = 3 x single + 1 x double fiber Keystones / Couplers
G = 1 x double module fiber O = 4 x single + 1 x double fiber c = Unshielded couplers
d = Shielded couplers
Note: A double module requires two places
u = Unshielded keystones
s = Shielded keystones
Mounting r = Unshielded Industrial REVConnect couplers
j = Unshielded Industrial REVConnect jacks
D = Standard DIN Rail
v = Shielded Industrial REVConnect jacks
W = Wall mount plate included
X = No housing Category
Fiber Splice Box Module d = CAT5E
e = CAT6
1 = Single module for 12 fibers a = CAT6A
2 = Double module for 24 fibers
Number of Connections
Adapter
2 = 2 keystones / couplers
B = ST – ST metal duplex adapters 4 = 4 keystones / couplers
T = ST – ST duplex adapters Example Module 3
M = SC – SC metal duplex adapters
S = SC – SC duplex adapters 1 N N N
L = LC – LC duplex adapters
E = E-2000 – E-2000 adapters
Blind Module
Application 1 = Single blind module
1 = MM/OM1 6 = 6 x SM/OS2 / 6 x OM2 2 = Double blind module
2 = MM/OM2 7 = 6 x SM/OS2 / 6 x OM3
3 = MM/OM3 8 = 6 x SM/OS2 / 6 x OM4
4 = MM/OM4 9 = SM/OS2 UPC Accessories for MIPP with Industrial REVConnect
5 = 6 x SM/OS2 / 6 x OM1 A = SM/OS2 APC
Tool 942-290-001 Universal Cable Crimping Tool
Note: 5- 8 for double module only
Cores: 942-290-002 Core pack 10 pcs.
Accessories • Cable Manager 942-290-003 Core Pack 20 pcs.
P = Pigtails • Termination Cap 942-290-004 Core Pack 50 pcs.
B = Brilliance field installable connectors For additional Fiber Splice Box and Copper Patch Panel accessories, please contact
N = No accessories customer service.

MIPP Pre-Terminated MPO Cassette Configurator


Housing Cassette 1 Cassette 2 Cassette 3 Cassette 4 Cassette 5 Cassette 6
M I P P / A D / P 4 M A / X X X X / X X X X / X X X X / X X X X / X X X X X X
Housing Fiber MPO Cassette
X = No housing P = Pre-Terminated MPO Cassette
A = 1 x single module
B = 2 x single module Fiber Type (Applications)
C = 3 x single module
4 = LC duplex MM/OM4
D = 4 x single module
9 = LC duplex SM/OS2 UPC
E = 5 x single module
F = 6 x single module
Connector (Trunk Side)
Mounting M = 1-port MPO-12 (m)
D = Standard DIN Rail
Polarity
W = Wall mount plate included
X = No housing A = Type A
For additional housings and cassette combinations, please contact customer service.

Example Part Numbers


Configuration Description in DIN Rail Design
MIPP/AD/P9MA MIPP with Pre-Terminated MPO Cassette with 6 LC OS2/UPC duplex adapters (blue) to 1 MPO-12 (male), Polarity Type-A
MIPP/AD/P4MA MIPP with Pre-Terminated MPO Cassette with 6 LC OM4 duplex adapters (aqua) to 1 MPO-12 (male), Polarity Type-A
Can be inserted in any slot of a MIPP housing

Belden, Belden Sending All The Right Signals, GarrettCom, Hirschmann, Lumberg Automation, Tofino Security, Tripwire and the Belden logo are trademarks or registered trademarks of Belden Inc. or its affiliated companies in
the United States and other jurisdictions. Belden and other parties may also have trademark rights in other terms used herein.

EMEA +49 (0) 7127/14-1809  |  hirschmann.com US 1-800-BELDEN-1  |  belden.com


4 ©Copyright 2019, Belden Inc. MIPP-MODULAR-INDUSTRIAL-PATCH-PANEL_PB00187_INET_HIR_1019_ENG

You might also like