101 Iso 10147-2004
101 Iso 10147-2004
101 Iso 10147-2004
STANDARD 10147
Second edition
2004-11-15
Reference number
ISO 10147:2004(E)
--`,,,`,,-`-`,,`,,`,`,,`---
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
--`,,,`,,-`-`,,`,,`,`,,`---
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.
© ISO 2004
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail [email protected]
Web www.iso.org
Published in Switzerland
ii
Copyright International Organization for Standardization © ISO 2004 – All rights reserved
Reproduced by IHS under license with ISO
No reproduction or networking permitted without license from IHS Not for Resale
ISO 10147:2004(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
--`,,,`,,-`-`,,`,,`,`,,`---
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 10147 was prepared by Technical Committee ISO/TC 138, Plastics pipes, fittings and valves for the
transport of fluids, Subcommittee SC 5, General properties of pipes, fittings and valves of plastic materials and
their accessories — Test methods and basic specifications.
This second edition cancels and replaces the first edition (ISO 10147:1994), which has been technically
revised.
1 Scope
This International Standard specifies a method for the assessment of the degree of crosslinking in
polyethylene (PE-X) pipes and fittings by determination of the gel content by solvent extraction.
2 Principle
The mass of a test piece taken from a pipe or a fitting is measured before and after immersion of the test
--`,,,`,,-`-`,,`,,`,`,,`---
piece in a solvent for a specified period of time. The degree of crosslinking is expressed as the percentage by
mass of the insoluble material.
3 Solvent
3.1 Xylene, analytically pure, to which 1 % of antioxidant has been added [either 2,2-methylene-
bis(4-methyl-6-t-butylphenol) or 3-(3,5-di-t-butyl-4-hydroxyphenyl) propionate, or a combination of both].
WARNING — Xylene is a harmful and inflammable solvent that can be absorbed through the skin and,
as such, should be handled carefully. Attention is drawn to any relevant regulations and associated
exposure limits. Use only in a ventilated hood. Check the effectiveness of the hood before starting the
test. Do not inhale the vapour. Excessive inhalation of the vapour may cause dizziness, headache or
both. In the event of excessive vapour inhalation, seek fresh, clean air.
4 Apparatus
4.1 Reflux condenser, of the general type shown in Figure 1.
4.3 Heating mantle, to fit the flask (4.2), and with sufficient heating capacity to boil xylene (boiling range:
138 °C to 144 °C).
4.4 Cage, with lid, large enough to contain a test piece (see Clause 5).
The cage shall be made of wire cloth or mesh, of aluminium or stainless steel, with a pore size of
(125 ± 25) µm. The wire cloth or mesh shall be free of grease, oil or other contaminants soluble in xylene. If
not, it shall be washed with acetone and dried before use.
4.5 Lathe with automatic feed, for machining out test pieces, or microtome or other suitable cutting
tool.
Key
A identification tag and fine wire attached to cage G variable transformer
B reflux condenser H water outlet
C ring clamp I stand
D water inlet J xylene
E ground-glass joint or cork K heating mantle
F wide-necked round-bottomed flask L wire cage enclosing test piece
4.6 Vacuum oven or forced-ventilation oven, capable of maintaining the specified conditions (see 6.6).
4.7 Balance, capable of weighing the cage, with or without a test piece, to an accuracy of 1 mg.
Each test piece shall comprise a slice or shaving having a thickness of (0,2 ± 0,02) mm, taken from a cross-
section of the pipe or fitting to include the full wall thickness round at least one circumference unless specified
otherwise by the referring standard. The mass of the test piece shall be W 0,2 g.
The degree of crosslinking can vary through the wall thickness of a pipe or fitting and therefore, for surface or
midwall measurements, test pieces shall be machined accordingly.
NOTE It is recommended that a lathe be used to machine test pieces from pipe. Alternatively, a microtome or other
suitable cutting tool may be used, and may be necessary for obtaining test pieces from fittings.
2
Copyright International Organization for Standardization
--`,,,`,,-`-`,,`,,`,`,,`---
© ISO 2004 – All rights reserved
Reproduced by IHS under license with ISO
No reproduction or networking permitted without license from IHS Not for Resale
ISO 10147:2004(E)
6 Procedure
6.1 Weigh a clean, dry cage, including its lid (see 4.4), to an accuracy of 1 mg (mass m1).
6.2 Place a test piece in the cage and weigh the cage and test piece together to an accuracy of 1 mg
(mass m2).
6.3 Place the cage and test piece in the flask (4.2) and ensure that there is sufficient xylene solvent to
maintain total immersion and to provide a ratio by mass of solvent to test piece of at least 200:1.
6.4 Boil the solvent vigorously to ensure good agitation for 8 h ± 30 min.
6.5 Carefully remove the cage and the residue of the test piece from the solvent after the time specified in
6.4. If the residue can be easily separated from the cage, place the residue only in pure boiling xylene for
5 min. If the residue cannot be separated from the cage and lid, place the complete assembly in pure boiling
xylene for 5 min.
NOTE Take care when removing the cage from the boiling solution (see warning in 3.1).
6.6 Complete the drying of the residue, or cage, lid and residue, by placing them for at least 3 h in:
a) either a vacuum oven (see 4.6), kept at (90 ± 2) °C under a vacuum (negative pressure) of at least
0,85 bar (85 kPa) (i.e. approximately 0,15 bar absolute pressure or less);
b) or a forced-ventilation oven (see 4.6), with an adequate extraction facility, kept at (140 ± 2) °C.
6.7 After drying, allow to cool to ambient temperature and weigh the residue (mass m4), or cage, lid and
residue (mass m3), to an accuracy of 1 mg.
m4
G= × 100
m 2 − m1
m 3 − m1
G= × 100
m 2 − m1
where
m2 is the mass of the original test piece, the cage and the lid, in milligrams;
The mass of any filler present in the material shall be taken into account.
8 Test report
The test report shall include the following information:
d) details of any variation in the specified procedure and of any abnormal behaviour observed during the
test;
--`,,,`,,-`-`,,`,,`,`,,`---
4
Copyright International Organization for Standardization © ISO 2004 – All rights reserved
Reproduced by IHS under license with ISO
No reproduction or networking permitted without license from IHS Not for Resale
--`,,,`,,-`-`,,`,,`,`,,`---
--`,,,`,,-`-`,,`,,`,`,,`---