Diaphragm Pump
DP-25 ALN Aluminium Neoprene
Sheet 1 of 10 FF - MM - 27 REV - 3
Diaphragm Pump DP-25 ALN
Operation & Maintenance Guide
Common Nomenclature for DP/DPB Series pumps. Safety
Always wear safety glasses in vicinity of an operating pump,
WETTED PARTS PUMP SIZES fluid being pumped may spray in case of diaphragm rupture.
Aluminium = Al 75 - 3” pump Necessary care should be taken if the fluid being pumped is
Stainless Steel = SS hazardous. Do not exceed 125 psi air supply pressure. Ensure
50 - 2” pump that all clamp bands are tightened correctly to specified
Polypropylene = PP
Cast iron = CI 40 - 1½” pump torques. Verify compatibility of fluid being pumped with pump
25 - 1” pump wetted parts. Before opening supply hose connections ensure
that supply has been shut off.
ELASTOMERS 12 - ½” pump
Suction capabilities
Neoprene =N
DP 25 Series pumps, under ideal conditions generate a
Buna N =B vacuum equivalent to 16 feet of water. Practically the amount of
PTFE =T suction head the pump will generate is dependant on many
Viton =V factors among them being atmospheric pressure, viscosity of
process fluid, density of the process fluid and number of bends
MODEL EXAMPLE in suction side of piping.
DP B 12 SS V Pipe Diameters recommended
Dp25 suction pipeline recommended diameters is 1inch.
Elastomer Suction side line should be non collapsible. Discharge pipe
line recommended diameter is 1 inch and air inlet 1/4 inch
Wetted parts Tightening torques recommended
Outer flange to Shaft 45 Nm
Size of pump Small Clamp Band 3.5 Nm
Large Clamp Band 11 Nm
Type of construction Air Valve Body to Housing 3.5 Nm
B - Bolted
W/O B - Clamped
COMPATIBLE FLUIDS
Diaphragm Pump NEOPRENE ELASTOMER DP-25ALN
Temperature range : 17.8º C to 93.3ºC
Air Supply An excellent general purpose diaphragm for use in non-aggressive
Compressed air at 90 psi, free from moisture and having an applications such as water based slurries, well water or sea water.
oil mist is essential. Use of filter regulator lubricator (FRL) unit Exhibits excellent flex life and low cost.
is highly recommended and should be installed as close as
possible to the pump inlet. Ensure that the correct grade of oil
is used to obtain proper shifting of the air valve. Too thick an
oil may cause the shifting mechanism to run slower than
normal and affect pump performance. See suggested
lubricants at bottom of this section.
Site Selection
Ideally the pump should be located in such a way that the
piping should have the minimum bends. This will keep friction
losses to a minimum and extend the pump parts life. The Troubleshooting
location should be easily accessible to make maintenance
easier. Try to install the pump in such a way to minimize the Problem Possible cause and solution
suction head for maximum pumping efficiency. See pump Pump will not run Air valve stuck, service or replace if worn.
performance at end of section for suction and delivering head Air supply insufficient, Check proper and
data. Ensure that the suction head is well within the pumps adequate air supply
capability. In areas where there is a possibility of a positive Check shaft operation, replace worn shaft or
suction head, a suitable gate valve is a must to allow for rings
pump maintenance. Diaphragm pumps generate vibratory
force due to the reciprocatory motion, ensure that suitable Pump runs Check ball seats and proper clamping
flexible piping is employed between the pump and pipelines. slowly Check air valve operation
Also the pump should be bolted down onto a solid Check shaft operation
foundation. Ensure that the correct pipe diameters are used,
especially if the fluid is of a viscous nature. See table at end of
section for proper selection of pipe diameter. Air valve freezing Remove moisture from air supply line
Should the application demand, these pumps can be used in
the submerged condition. In this situation exhaust air must be Air bubbles in Replace diaphragms
piped above the surface of the fluid. Diaphragm pumps are discharge and /
capable of handling considerable solid sizes. DP25 Series or fluid
pumps will let solids of 3.2mm diameter pass through. It is discharging from
preferable that a suitable strainer be installed on the suction air exhaust
line to prevent the possibility of ingress of larger particles. All
joints should be leak proof - leaky joints on suction side will
drastically affect the pumps suction head capabilities.
Sheet 2 of 10 FF - MM - 27 REV - 3
Diaphragm Pump DP-25 ALN
Operation & Maintenance Guide
Dis-assembly and Re-assembly
Shut off air supply and allow residual pressure to bleed off. the air valve body. If air valve is excessively worn and there is
Disconnect air supply considerable play in its motion, it should be replaced.
Disconnect inlet and outlet discharge lines Re-assemble the parts in reverse sequence of dis-assembly.
Turn upside down and allow process fluid to drain away. Coat the air valve and shaft with recommended oil and
Make a mark to indicate the positioning of each liquid assemble the air valve.
chamber relative to the housing. Check free motion of air valve in air valve body
Remove the small clamp band on one side and lift off the Tighten bolts within specified limits.
outlet Then remove small clamp band on bottom side and
remove inlet manifolds. Remove balls and seats from the
pump body.
Remove the Big clamp band on one side and lift away the
liquid chamber.
Unscrew the outer flange and remove the diaphragm
Do not damage the diaphragm during this operation
Unscrew the stud from the shaft
Repeat procedure for the other side diaphragm.
Take care not to dent or damage the shaft housing
Remove the O rings from the housing carefully
Unscrew the four screws holding the air valve assembly to Suggested Lubricants
the housing and lift off the assembly
Above 27 deg C 5 deg C to 27 deg C Below 5 deg C
The air valve is restrained by two circlips. Remove these (80 deg F) (40 degF to 80 degF) ( 40 deg F)
circlips on either side of the air valve. Caps can be removed Shell Toona R 72 Toona R 41 Toona R 27
by screwing in a suitable puller into the tapping and pulling Mobil Almo 529 Almo 527 Almo 525
them out. Slide out the air valve. Esso -- -- -- Arox EP 65 Arox EP 45
Clean all components with light oil and inspect for wear. Caltex Rando Oil 150 Rando Oil 100 Rando Oil 46
Specially ensure that there is no grit in the air valve cylinder Texaco Regal Oil F Regal Oil PE Regal Oil B
as this will interfere with valve motion and impede Daltron Silkolene 881 Silkolene 548 Silkolene 773
performance. Burmah Castrol RD Oil 3 RD Oil Light Megna SPX
Inspect all rubber components for wear as required. BP RD 220 HP60C RD150 HP20C RD80 HP10C
Inspect the diaphragms for wear marks and replace if wear Duckham Garnet 7 Garnet 6 Zero Flo 5
is excessive. Sternol Merlin 87 Merlin 71 Merlin 54
Inspect the shaft and housing O rings for wear and nicks Petrofina Purifoc 53 Purifoc 46 Purifoc 32
Chevron Vistac Oil 18X Vistac Oil 19X Vistac Oil 9X
and replace if necessary.
The air valve should be checked for smooth sliding within
6 200
8 0 psi air supply
80
20
15
5
cfm
cfm
10
25
cfm su
air
ai
rc
5
c
ai
ai r
cf
on
on
rc
su
co ion
40 y
on
ai
um
m
ns
rc
io
pt
pt
2 pt
um
n
on
su i on
50 20 psi air supply m
p ti
20 pt
1
on
io
n
0 0 0
0 5 10 15 20 25 30 35
(19) (38) (57) (76) (95) (114) (133)
Sheet 3 of 10 FF - MM - 27 REV - 3
Physical Dimensions for DP 25 Series
Sheet 4 of 10 FF - MM - 27 REV - 3
Diaphragm Pump DP-25 ALN
Exploded View
Sheet 5 of 10 FF - MM - 27 REV - 3
Diaphragm Pump DP-25 ALN
Assembly Part List
Illus. No. PART NO. DESCRIPTION QTY
1 160 10 06 Shaft housing with Bush 1
2 160 40 21 Square ring for Bush Insert 4
3 160 21 10 Shaft 1
4 160 21 09 Stud 2
5 160 30 12 Inner flange 2
6 160 10 05 Outer flange 2
7 160 40 20 Diaphragm 2
8 160 10 04 Outer chamber Side 2
9 160 40 15 Valve ball 4
10 160 10 03 Outlet 1
11 160 10 02 Inlet Base 1
12 160 30 13 Big clamp 4
13 160 90 32 Allen bolt for big clamp 4
14 022 40 21 Hex nut for big clamp 4
15 160 97 37 Air valve replacement kit 1
16 160 30 14 small clamp 8
17 150 40 28 Allen bolt for Small clamp 8
18 150 40 25 Hex nut for small clamp 8
19 160 40 18 Gasket for blocking pad 1
20 160 10 07 Blocking pad 1
21 150 40 26 Allen bolt for blocking pad 4
22 160 40 16 Valve ball Seat 4
- 150 97 35 Silencer (Optional) 1
- 160 2198 Nipple for Inlet / Outlet (Optional) 1
Note : Always use genuine TERYAIR spares part for best performance.
Sheet 6 of 10 FF - MM - 27 REV - 3
Diaphragm Pump DP-25
Air Valve Replacement Kit
Sheet 7 of 10 FF - MM - 27 REV - 3
TECHNICAL SPECIFICATION FOR DP25 DIAPHRAGM PUMP
Model No DP25ALN DP25ALB DP25ALT DPB25PPT DP25SST
Wetted Material Aluminium Aluminium Aluminium Polypropylene Stainless steel S.S
Non wetted part Aluminium Aluminium Aluminium Aluminium Aluminium
Elastomer Neoprene Buna PTFE PTFE PTFE
Ball material Neoprene Buna PTFE PTFE PTFE
Seat material Neoprene Buna Aluminium Polypropylene S.S.
O-ring N. A. N. A. PTFE PTFE PTFE
Air_inlet_detail ¼'' inch NPT ¼'' inch NPT ¼'' inch NPT ¼'' inch NPT ¼'' inch NPT
Fluid Inlet 1 ” inch NPT 1 ” inch NPT 1 ” inch NPT 1” inch FLANGED 1 ” inch BSPP
Fluid Outlet 1 ” inch NPT 1 ” inch NPT 1 ” inch NPT 1” inch FLANGED 1 ” inch BSPP
Suction lift 5.2mtrs 5.2mtrs 3mtrs 3mtrs 3m trs
Max_particle _size 3.2mm 3.2mm 3.2m m 3.2mm 3.2mm
Construction Clamp Clamp Clamp Bolted Clamp
Max_delivery 114 liters/min 114 liters/min 94 liters/min 80 liters/min 94 liters/m in
Temperature Limits:
Neoprene -17.8°C to 93.3°C 0°F to 200°F
Buna-N -12.2°C to 82.2°C 10°F to 180°F
EPDM -51°C to 137.8°C -60°F to 280°F
Viton® -40°C to 176.7°C -40°F to 350°F
PTFE 4°C to 104.4°C 40°F to 220°F
Sheet 8 of 10 FF - MM - 27 REV - 3
INTENDED USE
The Diaphragm Pumps are intended for pumping water , viscous fluids up to 10000 cps, acidic, alkaline and
abrasives slurries.
2) Suction Head
1) DPB-12 Head- 9 feet Head- 9 feet Head- 5 feet Head -5 feet Head -5 feet
2) DP-25 Head- 16 feet Head-16 feet Head-10 feet Head-10 feet Head-10
feet
3) DP-40 Head-16 feet Head-16 feet Head-10 feet Head-12 feet Head-12
feet
4) DP-50 Head-16 feet Head-16 feet Head-12 feet Head-12 feet Head-12
feet
5) DPB-75 Head-16 feet Head-16 feet Head-12 feet Head-12 feet Head-12
feet
Sheet 9 of 10 FF - MM - 27 REV - 3
PROHIBITIVE USE
Air operated double diaphragm pumps should not be used for purposes other than specified in
intended use and following conditions must always be complied with.
1. Maximum slurry particle size must not be greater than the pump's solid passage
capability. A strainer may be placed on the inlet line to eliminate particle larger than the
pump's capability. Please refer operation and maintenance guide for pump's specific
soilds passage
capabilities.
2. Suction and discharge head lift requirement must not be greater than the pump's suction
and discharge head lift capabilities as mentioned in operation and maintenance
guide. Suction and discharge head lift will vary depending on number of inlet and
discharge elbows, the viscosity of process fluid, elevation (atmospheric pressure) and
pipe friction loss.
3. Air line should be blown out for 10 to 20 second before attaching to pump to make sure
al pipe line debris is clear.
4. Pump should not be used for temperature beyond specified limit as mentioned in
operation and maintenance guide.
5. Diaphragm life not only depends on diaphragm's chemical compatibility with the process
fluids but also on the process conditions. These conditions will vary depending on the
abrasiveness of your process fluid temperature, size of diaphragm, pumping media and
liftconditions. Pump should not be used for highly abrasive fluids.
6. Safety glasses and suitable protective outerwear must be worn in vicinity of an operating
pump fluid being pumped may spray in case of diaphragm rupture. Necessary care should
be taken if the fluid being pump is hazardous.
7. Before opening supply hose connections ensure that supply has been shut off.
8. Operation and maintenance guide instruction should be followed before start operation
and during maintenance & cleaning.
9. Personal safety equipments like Hand gloves, safety shoes, eye protection etc should be
used.
10. Any internal part of pump assembly shall not be removed for independent operation or
other use.
11. Do not exceed 125psi air supply pressure unless it has been specifically allowed in the
operation and Maintenance Guide.
12. Instructions given in operation and maintenance guide regarding maintenance, Cleaning,
Safety & Operation should be strictly followed.
Sheet 10 of 10 FF - MM - 27 REV - 3