Lsj320ap04 e Samsung PDF
Lsj320ap04 e Samsung PDF
Lsj320ap04 e Samsung PDF
Product Information
SAMSUNG TFT-LCD
MODEL :
The Information Described in this Specification is Preliminary and can be changed without
prior notice
LCD Business
Samsung Electronics Co . , LTD.
Description
LSJ320AP04 is a color active matrix liquid crystal display (LCD) that uses amorphous
silicon TFT( Thin Film Transistor) as switching components. This model is composed of a
TFT LCD panel, a driver circuit. The resolution of a 32“ is 1366 x 768 and this model can
display up to 16.7 Million colors with wide viewing angle of 89° or higher in all directions.
This panel is intended to support applications to provide a excellent performance for Flat
Panel Display such as Home-alone Multimedia TFT-LCD TV and High Definition TV.
Features
High contrast Ratio & aperture ratio with wide color gamut
SVA (Super Vertical Align) mode
Wide viewing angle (±178°)
High speed response
HD resolution (16:9)
LVDS (Low Voltage Differential Signaling) interface
General Information
Weight 1.2(Max) kg
Pixel Pitch 0.51075(H) X 0.17025(V) mm
Active Display Area 697.6845(H) X 392.256(V) mm
Surface Treatment Haze 2%, Hard-coating (2H)
Glass surface
temperature Center TOPR 0 50 ℃ (2)
(Operation)
Response (3)
G-to-G Tg - 10 16 msec
Time RD-80S
Rx Normal 0.640
Red
Ry qL,R=0 0.330
qU,D=0
Gx 0.300
Green Viewing
Color Gy 0.600
Angle TYP. TYP. (5),(6)
Chromaticity
Bx -0.03 0.150 +0.03 D65
(CIE 1931)
Blue
By 0.060
Wx 0.280
White
Wy 0.290
sRGB Concordance - - 98.5 - % (5)
Color Temperature - - 10,000 - K D65
qL 75 89 -
Hor.
Viewing qR 75 89 - (6)
C/R≥10 Degree EZ-
Angle qU 75 89 - Contrast
Ver.
qD 75 89 -
Notice
Photo detector
Photo detector Field
SR3 1°
RD-80S 2° Field
BM-5A : 50㎝
RD-80S : 50㎝
EZ-Contrast:0㎝
TFT - LCD Module
LCD Panel
Active Area
180 ⑨ ⑧ ⑦
Test Point
540 ⑥ ⑤ ④
900 ③ ② ①
G max
C/R
G min
Gmax : Luminance with all pixels white
Gmin : Luminance with all pixels black
Display data Black (data off) White (data on) Black (data off)
TR TF
Optical Instruments
100%
Response
90%
10%
0%
TIME
※ G-to-G : Average response time between Gray to Gray (Scale)
Note (1) The ripple voltage should be controlled under 10% of VDD.
(2) fV= 60 Hz, fDCLK = 78 MHz, VDD = 12.0V, DC Current.
(3) Power dissipation check pattern (LCD Module only)
a) Black Pattern b) White Pattern c) N-pattern
VDD
100%
90%
10%
GND
TRUSH=470㎲
Rush Current IRUSH can be measured when TRUSH. is 470㎲.
Note1) No Connection: These PINS are used only for SAMSUNG. (DO NOT CONNECT)
PCB
#1 #30 #1 #10
TxIN/RxOUT0 R2
TxIN/RxOUT1 R3
TxIN/RxOUT2 R4
TxOUT/RxIN0 TxIN/RxOUT3 R5
TxIN/RxOUT4 R6
TxIN/RxOUT6 R7
TxIN/RxOUT7 G2
TxIN/RxOUT8 G3
TxIN/RxOUT9 G4
TxIN/RxOUT12 G5
TxOUT/RxIN1 TxIN/RxOUT13 G6
TxIN/RxOUT14 G7
TxIN/RxOUT15 B2
TxIN/RxOUT18 B3
TxIN/RxOUT19 B4
TxIN/RxOUT20 B5
TxIN/RxOUT21 B6
TxOUT/RxIN2 TxIN/RxOUT22 B7
TxIN/RxOUT24 HSYNC
TxIN/RxOUT25 VSYNC
TxIN/RxOUT26 DEN
TxIN/RxOUT27 R0
TxIN/RxOUT5 R1
TxIN/RxOUT10 G0
TxOUT/RxIN3 TxIN/RxOUT11 G1
TxIN/RxOUT16 B0
TxIN/RxOUT17 B1
TxIN/RxOUT23 RESERVED
Vsync FV 48 60 66 HZ
Active
Display TVD - 768 - Lines
Vertical Period
Display Term
Vertical
TVB 776 802 1200 Lines
Total
Active
Display THD - 1366 - Clocks
Horizontal Period
Display Term
Horizontal
TH 1480 1624 2000 clocks
Total
Note) This product is DE only mode. The input of Hsync & Vsync signal does
not have an effect on normal operation.
(1) Test Point : TTL control signal and CLK at LVDS Tx input terminal in system
(2) Internal VDD = 3.3V
(3) Spread spectrum
- Modulation rate (max) : ± 1.5 %
- Modulation Frequency : 30 ~ 300KHz
TV
TVD
DE
TH
THD
DE
DCLK
TC
DATA
SIGNALS
0.5ms<T1≤10ms
1ms<T2≤50ms
0ms<T3≤50ms
1000ms≤T4
1000ms≤T5
100ms≤T6
The supply voltage of the external system for the Module input should be the same
as the definition of VDD.
Apply the lamp voltage within the LCD operation range. When the back light turns on
before the LCD operation or the LCD turns off before the back light turns off,
the display may momentarily show abnormal screen.
In case of VDD = off level,
please keep the level of input signals low or keep a high impedance.
T4 should be measured after the Module has been fully discharged between power off
and on period.
Interface signal should not be kept at high impedance when the power is on.
10EA 10EA
10EA
Pallet-Plastic
1. 23 Kg / Pallet-Plastic (1ea)
Pallet-Wood 1Box / Pallet
2. 2.00 Kg / Packing Pallet-Box(1ea)
LSJ320AP04
LSJ320AP04
xxxx
140
9.1 Handling
(a) When the Module is assembled, it should be attached to the system firmly
using all mounting holes. Be careful not to twist and bend the Module.
(b) Refrain from strong mechanical shock and / or any force to the Module.
In addition to damage, this may cause improper operation or damage to the Module
and CCFL back light.
(c) Note that polarizers are very fragile and could be damage easily.
Do not press or scratch the surface harder than a HB pencil lead.
(d) Wipe off water droplets or oil immediately. If you leave the droplets for a long
time, staining or discoloration may occur.
(e) If the surface of the polarizer is dirty, clean it using absorbent cotton or soft cloth.
(g) If the liquid crystal material leaks from the panel, it should be kept away
from the eyes or mouth . In case of contact with hands, legs or clothes, it must
be washed away with soap thoroughly.
(h) Protect the module from Electrostatic discharge. Otherwise the ASIC IC or
Semiconductor would be damaged.
(i) Use finger-stalls with soft gloves in order to keep display clean during the
incoming inspection and assembly process.
(k) Protection film for polarizer on the Module should be slowly peeled off just before use
so that the electrostatic charge can be minimized. Must put on antistatic glove while
handle a module
(l) Pins of I/F connector should not be touched directly with bare hands.
6 Temperature 0 ∼ 35℃
7 Humidity 60 to 70 [%RH]
Storage
(℃) 5 40
Temperature
Storage
(%rH) 35 75
Humidity
- The storage room should provide good ventilation and temperature control.
- Products should not be placed on the floor, but on the Pallet away from
a wall.
- Prevent products from direct sunlight, moisture nor water; Be cautious of
Storage a build up of condensation.
- Avoid other hazardous environment while storing goods.
Condition
9.3 Operation
(a) Do not connect or disconnect the Module in the "Power On" condition.
(b) Power supply should always be turned on/off by the "Power on/off sequence"
(c) Module has high frequency circuits. Sufficient suppression to the electromagnetic
interference should be done by system manufacturers. Grounding and shielding methods
may be important to minimize the interference.
(d) The cable between the back light connector and its inverter power supply should
be connected directly with a minimized length. A longer cable between
the back light and the inverter may cause lower luminance of lamp(CCFT) and
may require higher startup voltage(Vs).
(b) If the product will be used in extreme conditions such as high temperature,
humidity, display patterns or operation time etc.., It is strongly recommended
to contact SEC for Application engineering advice. Otherwise, its reliability and
function may not be guaranteed. Extreme conditions are commonly found at
Airports, Transit Stations, Banks, Stock market, and Controlling systems.
9.5 Others
(c) Do not exceed the absolute maximum rating value. ( supply voltage variation,
input voltage variation, variation in part contents and environmental temperature,
and so on)
Otherwise the Module may be damaged.
(d) If the Module keeps displaying the same pattern for a long period of time,
the image may be "sticked" to the screen.
To avoid image sticking, it is recommended to use a screen saver.
(e) This Module has its circuitry PCB's on the rear side and should be handled
carefully in order not to be stressed.
(f) Please contact SEC in advance when you display the same pattern for a long time.