DESIGN OF 20.00 M RCC SUPERSTRUCTURE
RCC/GIRDER/174+
DESIGN NOTE NO.: R-0 DATE : 9-May-19
311
INDEX
SR NO SUBJECT
1 INTRODUCTION
2 PREAMBLE
3 DATA SHEET
4 GRID FIXING
The design of RCC Girder for 20 m span for following Chainages are being submitted herewith.
Chainages
The span consists of 4 nos of Precast RCC girder with end diaphragm at either end.
MATERIAL PROPERTIES
Limit State
Material Details Method Units Reference
Basic & Seismic
Ref: Fig 6.2, Note (1)
Partial safety 1.15 combination
Accidental of IRC :112-2011, pg
factor, ϒm
1 combination 30
Ultimate design
yield stress = 0.87fy 434.78 N/mm2
(Serviceability Limit
Allowable tensile State) Ref: Cl.12.2.2 of
stress, fs = 0.8fy 400.00 N/mm2 IRC :112-2011, pg 120
Composite action is considered for the slab load, SDIL and live loads. Slabs are provided sloped in the
Ø direction of required camber. Girders are accordingly raised with higher pedestals.
Live loads are run in position concentric to all the 4 girders, and combinations are worked out based
Ø on the minimum distance between the two lanes.
Diaphragm loads are taken from the above for service condition and a separate analysis with
Ø changed supports for jack up condition.
REFERENCE CODES
Standard specification and code of practice for road bridges
IRC :6-2014 (Section II – Loads and stresses)
IRC :112-2011 Standard specifications and code of practice for road bridges
The construction of the High Level bridge at Ch. 174+311 is proposed. The General Arrangement
proposed is as shown in GAD drawing . The precast RCC-I Girder with 225mm thk deck slab is proposed.
The dead load & live load calculations are given in the subsequent calculations. The thickness of deck
slab is 0.225m. The analysis of the live load & SIDL is carried out using Grillage Method. The
calculations are done to established the flexture and shear reinforcement, Support reactions only.
The cross girder and slab design will be provided later with supersturcture design.
2 Materials :-
a) Concrete & Steel :-
Controlled concrete of M40 Grade giving Characteristic strength of 400 kg/cm 2 on 150 mm cubes tested
at 28 days is proposed for the Precast PSC I Girder
The Steel is HYSD Fe 500 & HTS.
3 Loading Consideration :-
The following loads and load combination as per IRC-6 : 2014 have been considered as given below:
1) Dead Load ( Self weight of structure, Superstructure, SIDL, Wearing Course) (G, G1 & G2)
2) Live load ( Q )
Cases :-
a) Class 70 R Wheeled + Class A
b) Class 70 R Tracked + Class A
c) Class A1
d) Class A - 3 Lane
3.1 Dead Load (DL)
Unit weight for Dead Loads calculation has been considered by adopting unit weights as per IRC: 6 –
2015 (Standard Specifications and Code of Practice for Road Bridges, Section-II – Loads and Stresses).
3.5 Loadcombination
Load due to Temperature Variation
as per IRC 6 : 2014 is considered in the Design Calculation
Load combination for Limit state given in Annexure B of IRC:6-2014 has been considered.
The following limit states are considered:
1. Ultimate Limit State (ULS)
Under this limit state, capacity of section to carry bending moment and shear force is checked.
2. Serviceability Limit State (SLS)
Under this limit state, stress in concrete and reinforcement, crack width and deflection are checked.
For checking crack width, quasi-permanent combination is used.
6 Analysis
The analysis of the PSC T Beam Girder has been modelled as a 2D structure in STAAD PRO by the
consultant. The Dead load, Superimposed Dead Load (comprises of Wearing coat and Crash barrier),
Live load of 70R Class A, 2 Lanes of Class A and & Class AA in third lane is applied as per Morrice Little
Method as cross check for moemnts and shears.
7
7.1 Concrete Grades and Reinforcements
Concrete:
Grade of concrete (PSC I girder) - M35
Grade of Concrete (PCC Works) - M15
Reinforcement:
HYSD bars (Grade Fe – 500D) conforming to IS: 1786-2008 are provided as reinforcement.
Clear Cover:
The minimum cover to reinforcement has been determined from the recommendations of IRC: 112-2011
taking into account the local environmental conditions. Following clear cover has been adopted for
the various components:
Structural components (foundation) - 75 mm
Structural components (Substructure and Superstructure) - 40 mm
Condition of Exposure:
Condition of exposure is taken as moderate
Ultimate Limit State (For Verification of Structural Strength)(Table 3.2, Annex B, IRC:6-2014)
Basic Seismic
Load Comb Comb
Dead Load 1.35 1.35
SIDL (except 1.35 1.35
surfacing)
1.75 1.75
SIDL (surfacing)
Live load and
associated loads 1.5 0
(Leading)
Live load and
1.15 0.2
associated loads
1 1
Water Current
0.15 0.15
Buoyancy
1.5 1.5
Earth Pressure
Live load
1.2 0.2
surcharge
Hydrodynamic
- 1
Effect
1.5 -
Wind (Leading)
Wind
0.9 -
(Accompanying)
Seismic Effect
- 1.5
(During service)
Seismic Effect
(During - 0.75
construction)
For Materials
Basic Seismic
Material
Comb Comb
Concrete 1.5 1.5
Reinforcing steel 1.15 1.15
Temperature
variation = 42.5 oC
=
7.46 Condition of Exposure = Moderate
Seismic forces need to be considered = No
2 SIDL Data
3 Material Data
Grade of Concrete - slab = M 35
Grade of Concrete - Girder = M 35
Grade of Steel = Fe 500
Conditions of Exposure = Moderate 1
Density of Reinforced Concrete = 2.5 t/m3
4 GIRDER DATA
From C/L Of From DIST. BETn DIST. FROM DIST. OF SECTn
Bearing (mm) Face SECTn (m) ANCH.(mm) FROM MID.(mm)
SECTION Of
Girder
(mm)
SECTION 1-1 = 0.00 400 0.000 280 9500
SECTION 2-2 = 1900 2300 1.900 2180 7600
SECTION 3-3 = 3800 4200 1.900 4080 5700
SECTION 4-4 = 5700 6100 1.900 5980 3800
SECTION 5-5 = 7600 8000 1.900 7880 1900
SECTION 6-6 = 9500 9900 1.900 9780 0
constant section 139 149 0.31500 0.00000 0.05145 0.00133 0.225 m 1.400 m 0.788 t/m
231 241 0.31500 0.00000 0.05145 0.00133 0.225 m 1.400 m 0.788 t/m
162 172 0.31500 0.00000 0.05145 0.00133 0.225 m 1.400 m 0.788 t/m
185 195 0.31500 0.00000 0.05145 0.00133 0.225 m 1.400 m 0.788 t/m
208 218 0.31500 0.00000 0.05145 0.00133 0.225 m 1.400 m 0.788 t/m
Total L = 19.000 m
Load 1 Load 5
2.531 t/m Load 2 Load 3 Load 4 2.531 t/m
1.744 t/m
0.250 m
0.600 m
C/S OF GIRDER AT CENTRE
Beff 0.600 m
0.9 m 0.225 m
0 0.375 m
0.150 m
0.050 m
1.350 m 0.500 m
0.600 m 1.150 m
overall 1.825 m SECTION THROUGH DIAPHRAGM
0.000 m
0.250 m
0.600 m
C/S OF GIRDER AT ENDS - WIDENED SECTION
CL of Pier CL of bearing
0.600 m 1.000 m
CL of Girder 0.600 m
Sectional Properties
(1) (1)
600 600
3250
At End Section
1750 1500
900 ( 10 ) 900
Deck slab 225
(1) (1)
0 0 0
600 600
Details Girder Composite Girder Composite Girder Composite End section 1 One side
2
Area in m 0.698 1.429 0.855 1.586 1.013 1.744 Varying sec. 1.5 One side
4
Moment of Inertia about x-x axis, Ix-x in mm 0.201 0.481 0.215 0.520 0.230 0.559 Mid section 7 upto C/L
4
Moment of Inertia about y-y axis, Iy-y in mm 0.019 0.668 0.028 0.677 0.036 0.686
C.G about x-x axis from top of slab in m 0.543 0.582 0.621
C.G about x-x axis from top of girder in m 0.769 0.318 0.766 0.357 0.763 0.396
C.G about x-x axis from bottom of girder in m 0.831 1.282 0.834 1.243 0.837 1.204
Section modulus about x-x (top of girder) 0.261 1.514 0.281 1.463 0.302 1.411
Section modulus about x-x (bot of girder) 0.242 0.375 0.258 0.420 0.275 0.464
Cross section of Girder at Mid Section Cross section of Girder at End Section
Girder Girder
Sectional Properties
(1) (1)
600 600
3000
At End Section
1500 1500
900 ( 10 ) 900
Deck slab 225
(1) (1)
0 0 0
600 600
Details Girder Composite Girder Composite Girder Composite End section 1 One side
2
Area in m 0.698 1.373 0.855 1.530 1.013 1.688 Varying sec. 1.5 One side
4
Moment of Inertia about x-x axis, Ix-x in mm 0.201 0.470 0.215 0.507 0.230 0.544 Mid section 7 upto C/L
4
Moment of Inertia about y-y axis, Iy-y in mm 0.019 0.526 0.028 0.534 0.036 0.542
C.G about x-x axis from top of slab in m 0.560 0.599 0.638
C.G about x-x axis from top of girder in m 0.769 0.335 0.766 0.374 0.763 0.413
C.G about x-x axis from bottom of girder in m 0.831 1.265 0.834 1.226 0.837 1.187
Section modulus about x-x (top of girder) 0.261 1.402 0.281 1.359 0.302 1.316
Section modulus about x-x (bot of girder) 0.242 0.372 0.258 0.415 0.275 0.458
Cross section of Girder at Mid Section Cross section of Girder at End Section
Girder Girder
SECTIONAL PROPERTIES
GIRDER : End Diaphragm
LOCATION: Supports
Y
xc
0.600 m 0.600 m Grade of Precast Girder = M40
E of Girder = 33000.0 GPa
0.500 m 1
0.4 m Grade of Cast - in situ slab = M40
E of Girder = 33000.0 GPa
yc 2 0.00 m
3a 3b 0.00 m
X 4
X
0.500 m
1.73 m 1.35 m
5a 5b 0.00 m
6
0.00 m
0.500 m
Y
1 1.200 m 0.375 m R 0.450 0.000 0.188 0.000 0.084 0.0053 0.0540 0.0105 0.0000 0.518 0.000 0.121
0 0.500 m 0.000 m R 0.000 0.000 0.375 0.000 0.000 0.0000 0.0000 0.0000 0.0000 0.330 0.000 0.000
3a 0.000 m 0.000 m T 0.000 -0.250 0.375 0.000 0.000 0.0000 0.0000 0.0000 0.2500 0.330 0.000 0.000
3b 0.000 m 0.000 m T 0.000 0.250 0.375 0.000 0.000 0.0000 0.0000 0.0000 -0.2500 0.330 0.000 0.000
4 0.500 m 1.350 m R 0.675 0.000 1.050 0.000 0.709 0.1025 0.0141 0.0563 0.0000 -0.345 0.000 0.080
5a 0.000 m 0.000 m T 0.000 -0.250 1.725 0.000 0.000 0.0000 0.0000 0.0000 0.2500 -1.020 0.000 0.000
5b 0.000 m 0.000 m T 0.000 0.250 1.725 0.000 0.000 0.0000 0.0000 0.0000 -0.2500 -1.020 0.000 0.000
6 0.500 m 0.000 m R 0.000 0.000 1.725 0.000 0.000 0.0000 0.0000 0.0000 0.0000 -1.020 0.000 0.000
1.125 0.000 0.793 0.108 0.068 0.067 0.000 0.201
4 2
yc = 0.793 / 1.125 = 0.705 m Iz = 0.309 m Area = 1.125 m
4 2
xc = 0.000 / 1.125 = 0.000 m Iy = 0.068 m Area of girder = 0.675 m
Itor = 0.067 m4
SECTIONAL PROPERTIES
GIRDER : Interior Diaphragm
LOCATION: Centre of Span
Y
xc
0.150 m 0.150 m Grade of Precast Girder = M40
E of Girder = 33000.0 GPa
0.500 m 1
0.4 m Grade of Cast - in situ slab = M40
E of Girder = 33000.0 GPa
yc 2 0.00 m
3a 3b 0.00 m
X 4
X
0.300 m
1.73 m 1.35 m
5a 5b 0.00 m
6
0.00 m
0.300 m
Y
1 0.300 m 0.375 m R 0.113 0.000 0.188 0.000 0.021 0.0013 0.0008 0.0017 0.0000 0.675 0.000 0.051
0 0.500 m 0.000 m R 0.000 0.000 0.375 0.000 0.000 0.0000 0.0000 0.0000 0.0000 0.488 0.000 0.000
3a 0.100 m 0.000 m T 0.000 -0.183 0.375 0.000 0.000 0.0000 0.0000 0.0000 0.1833 0.488 0.000 0.000
3b 0.100 m 0.000 m T 0.000 0.183 0.375 0.000 0.000 0.0000 0.0000 0.0000 -0.1833 0.488 0.000 0.000
4 0.300 m 1.350 m R 0.405 0.000 1.050 0.000 0.425 0.0615 0.0030 0.0122 0.0000 -0.188 0.000 0.014
5a 0.000 m 0.000 m T 0.000 -0.150 1.725 0.000 0.000 0.0000 0.0000 0.0000 0.1500 -0.863 0.000 0.000
5b 0.000 m 0.000 m T 0.000 0.150 1.725 0.000 0.000 0.0000 0.0000 0.0000 -0.1500 -0.863 0.000 0.000
6 0.300 m 0.000 m R 0.000 0.000 1.725 0.000 0.000 0.0000 0.0000 0.0000 0.0000 -0.863 0.000 0.000
0.518 0.000 0.446 0.063 0.004 0.014 0.000 0.065
4 2
yc = 0.446 / 0.518 = 0.863 m Iz = 0.128 m Area = 0.518 m
4 2
xc = 0.000 / 0.518 = 0.000 m Iy = 0.004 m Area of girder = 0.405 m
Itor = 0.014 m4
LOCATION
SLAB
Sl. No.
No. DL SIDL FPLL DL
Distance LOADS
1 1 2 3 4 5 6
Load case 1 2 3 4
1 0.000 23 Start 0.00 0.00 0.00 0.00 17.98
2 0.250 23 End -4.42 -4.94 -4.22 0.00 -17.34
3 0.500 24 End -8.67 -9.75 -8.33 0.00 -16.71
4 0.750 25 End -12.77 -14.43 -12.32 0.00 -16.08
5 1.000 26 End -16.71 -19 -16.2 0.00 -15.45
6 1.750 27 End -27.69 -31.93 -27.16 0.00 -13.84
7 2.500 28 End -37.47 -43.27 -36.71 0.00 -12.24
8 3.900 29 End -52.89 -60.54 -51.11 0.00 -9.79
9 5.300 30 End -64.89 -73.94 -62.21 0.00 -7.35
10 6.700 31 End -73.46 -83.51 -70.08 0.00 -4.90
GIRDER G1
LOCATION
SLAB
Sl. No.
No. DL SIDL FPLL DL
Distance LOADS
1 1 2 3 4 5 6
Load case 1 2 3 4
24 0.000 45 Start 0.00 0.00 0.00 0.00 17.91
25 0.250 45 End -4.4 -3.88 -0.1 0.00 -17.28
26 0.500 46 End -8.64 -7.67 -0.2 0.00 -16.65
27 0.750 47 End -12.72 -11.36 -0.31 0.00 -16.02
28 1.000 48 End -16.65 -14.95 -0.42 0.00 -15.38
29 1.750 49 End -27.59 -25.17 -0.79 0.00 -13.78
30 2.500 50 End -37.32 -34.15 -1.19 0.00 -12.18
31 3.900 51 End -52.67 -47.91 -1.96 0.00 -9.74
32 5.300 52 End -64.6 -58.63 -2.67 0.00 -7.3
GIRDER - G2
LOCATION
SLAB
Sl. No.
No. DL SIDL FPLL DL
Distance LOADS
1 1 2 3 4 5 6
Load case 1 2 3 4
47 0.000 67 Start 0.00 0.00 0.00 0.00 17.91
48 0.250 67 End -4.4 -3.88 -0.1 0.00 -17.28
49 0.500 68 End -8.64 -7.67 -0.2 0.00 -16.65
50 0.750 69 End -12.72 -11.36 -0.31 0.00 -16.02
51 1.000 70 End -16.65 -14.95 -0.42 0.00 -15.38
52 1.750 71 End -27.59 -25.17 -0.79 0.00 -13.78
53 2.500 72 End -37.32 -34.15 -1.19 0.00 -12.18
54 3.900 73 End -52.67 -47.91 -1.96 0.00 -9.74
55 5.300 74 End -64.6 -58.63 -2.67 0.00 -7.3
GIRDER - G3
LOCATION
SLAB
Sl. No.
No. DL SIDL FPLL DL
Distance LOADS
1 1 2 3 4 5 6
Load case 1 2 3 4
70 0.000 89 Start 0.00 0.00 0.00 0.00 17.98
71 0.250 89 End -4.42 -4.94 -4.22 0.00 -17.34
72 0.500 90 End -8.67 -9.75 -8.33 0.00 -16.71
73 0.750 91 End -12.77 -14.43 -12.32 0.00 -16.08
74 1.000 92 End -16.71 -19 -16.2 0.00 -15.45
75 1.750 93 End -27.69 -31.93 -27.16 0.00 -13.84
76 2.500 94 End -37.47 -43.27 -36.71 0.00 -12.24
77 3.900 95 End -52.89 -60.54 -51.11 0.00 -9.79
78 5.300 96 End -64.89 -73.94 -62.21 0.00 -7.35
GIRDER - G4
DiStance
Section
SL. NO
Tap End 1.0 -17 -17 -16 -15 -16 -16 -39 3 40 -17 -17 -16 -15 -16 -16 -42 3 40
2 0.1 L 1.9 -30 -31 -29 -13 -14 -14 -69 5 37 -30 -31 -29 -13 -14 -14 -73 5 37
Tap St 2.5 -37 -39 -37 -12 -13 -13 -87 6 36 -37 -39 -37 -12 -13 -13 -94 6 34
3 0.2 L 3.8 -52 -55 -50 -10 -11 -10 -123 9 31 -52 -55 -50 -10 -11 -10 -129 9 29
4 0.3 L 5.7 -67 -72 -64 -7 -7 -7 -162 12 25 -67 -72 -64 -7 -7 -7 -166 12 22
GIRDER G1
5 0.4 L 7.6 -77 -82 -73 -3 -4 -4 -189 14 19 -77 -82 -73 -3 -4 -4 -189 14 16
6 0.5 L 9.5 -80 -86 -76 0 0 -1 -199 15 15 -80 -86 -76 0 0 -1 -199 15 15
Distance
Section
SL. NO Moments Force -BM
Girder
ning
SLAB SLAB LL - SF SLAB SLAB
LL -
DL LOAD SIDL DL LOAD SIDL Sag Hog DL LOAD SIDL DL LOAD SIDL Sag Hog
SF
S S S S
1 0.00 L 0.0 0 0 0 -18 -17 0 0 0 51 0 0 0 -18 -17 0 0 0 51
Tap End 1.0 -17 -16 0 -15 -15 0 -48 2 48 -17 -16 0 -15 -15 0 -52 2 48
2 0.1 L 1.9 -30 -29 -1 -13 -13 0 -84 3 43 -30 -29 -1 -13 -13 0 -90 3 43
Tap St 2.5 -37 -36 -1 -12 -12 -1 -106 3 42 -37 -36 -1 -12 -12 -1 -113 3 42
3 0.2 L 3.8 -52 -51 -2 -10 -10 -1 -147 4 36 -52 -51 -2 -10 -10 -1 -154 4 36
Distance
Section
SL. NO Moments Force -BM
Girder
ning
SLAB SLAB LL - SF SLAB SLAB
LL -
DL LOAD SIDL DL LOAD SIDL Sag Hog DL LOAD SIDL DL LOAD SIDL Sag Hog
SF
S S S S
1 0.00 L 0.0 0 0 0 -18 -17 0 0 0 52 0 0 0 -18 -17 0 0 0 52
Tap End 1.0 -17 -16 0 -15 -15 0 -50 2 50 -17 -16 0 -15 -15 0 -51 2 47
2 0.1 L 1.9 -30 -29 -1 -13 -13 0 -86 3 45 -30 -29 -1 -13 -13 0 -87 3 43
Tap St 2.5 -37 -36 -1 -12 -12 -1 -110 3 43 -37 -36 -1 -12 -12 -1 -110 3 39
3 0.2 L 3.8 -52 -51 -2 -10 -10 -1 -150 4 38 -52 -51 -2 -10 -10 -1 -150 4 34
Distance
Section
SL. NO Moments Force -BM
Girder
ning
SLAB SLAB LL - SF SLAB SLAB
LL -
DL LOAD SIDL DL LOAD SIDL Sag Hog DL LOAD SIDL DL LOAD SIDL Sag Hog
SF
S S S S
1 0.00 L 0.0 0 0 0 -18 -18 17 0 0 42 0 0 0 -18 -18 17 0 0 42
Tap End 1.0 -17 -17 -16 -15 -16 -16 -39 2 40 -17 -17 -16 -15 -16 -16 -42 2 40
2 0.1 L 1.9 -30 -31 -29 -13 -14 -14 -69 4 37 -30 -31 -29 -13 -14 -14 -73 4 37
Tap St 2.5 -37 -39 -37 -12 -13 -13 -87 5 36 -37 -39 -37 -12 -13 -13 -94 5 33
3 0.2 L 3.8 -52 -55 -50 -10 -11 -10 -123 7 31 -52 -55 -50 -10 -11 -10 -129 7 29
4 0.3 L 5.7 -67 -72 -64 -7 -7 -7 -162 9 25 -67 -72 -64 -7 -7 -7 -166 9 22
GIRDER G4
5 0.4 L 7.6 -77 -82 -73 -3 -4 -4 -189 11 19 -77 -82 -73 -3 -4 -4 -189 11 17
6 0.5 L 9.5 -80 -86 -76 0 0 -1 -199 12 15 -80 -86 -76 0 0 -1 -199 12 15
Rare Combination - 1.00*(DL+SIDL) + + 1.00 *(LL) Frequent Combination - 1.00*(DL+SIDL) + + 0.75 *(LL)
Distance
Distance
Section
Section
Girder 1 Girder 2 Girder 3 Girder 4 Girder 1 Girder 2 Girder 3 Girder 4
BM SF BM SF BM SF BM SF BM SF BM SF BM SF BM SF
Units Units
tm t tm t tm t tm t tm t tm t tm t tm t
Tap End 1.0 -92 87 -85 79 -84 77 -92 87 Tap End 1.0 -81 77 -72 67 -71 66 -81 77
0.10 L 1.9 -163 79 -148 70 -146 70 -163 79 0.10 L 1.9 -145 70 -126 59 -124 59 -145 70
Tap St 2.5 -207 71 -187 66 -184 64 -207 71 Tap St 2.5 -184 63 -159 56 -157 54 -184 63
0.20 L 3.8 -286 60 -258 57 -254 55 -286 60 0.20 L 3.8 -253 53 -219 48 -216 46 -253 53
0.30 L 5.7 -370 43 -330 42 -332 42 -370 43 0.30 L 5.7 -328 38 -282 35 -283 35 -328 38
0.40 L 7.6 -421 28 -377 30 -377 30 -421 28 0.40 L 7.6 -374 23 -322 24 -322 24 -374 24
0.50 L 9.5 -441 16 -393 19 -392 21 -441 16 0.50 L 9.5 -391 12 -336 14 -335 16 -391 12
Quasi - Permanent Combination - 1.00*(DL+SIDL) + + 0.00 *(LL) Basic Combination - 1.35*(DL+SIDL) + + 1.50 *(LL)
Distance
Distance
Section
Section
Girder 1 Girder 2 Girder 3 Girder 4 Girder 1 Girder 2 Girder 3 Girder 4
BM SF BM SF BM SF BM SF BM SF BM SF BM SF BM SF
Units Units
tm t tm t tm t tm t tm t tm t tm t tm t
Tap End 1.0 -50 47 -33 31 -33 31 -50 47 Tap End 1.0 -130 123 -123 114 -121 112 -130 124
0.10 L 1.9 -90 42 -59 27 -59 27 -89.5 42 0.10 L 1.9 -231 112 -214 101 -210 101 -231 112
Tap St 2.5 -113 38 -75 24 -75 24 -113 38 Tap St 2.5 -293 101 -270 95 -265 92 -293 101
0.20 L 3.8 -157 31 -104 20 -104 20 -157 31 0.20 L 3.8 -405 85 -371 82 -365 79 -405 85
0.30 L 5.7 -204 21 -137 14 -137 14 -204 21 0.30 L 5.7 -524 62 -475 61 -478 60 -524 62
0.40 L 7.6 -232 11 -156 7 -156 7 -232 11 0.40 L 7.6 -597 40 -541 43 -542 44 -597 40
0.50 L 9.5 -242 1 -163 0 -163 0 -242 1 0.50 L 9.5 -625 23 -566 28 -563 31 -625 24
BM SF BM SF BM SF BM SF BM SF BM SF BM SF BM SF
m tm t tm t tm t tm t tm t tm t m tm t tm t
1.0 -92 87 -85 79 -81 77 -72 67 -50 47 -33 31 1.0 -130 124 -123 114
1.9 -163 79 -148 70 -145 70 -126 59 -90 42 -59 27 1.9 -231 112 -214 101
2.5 -207 71 -187 66 -184 63 -159 56 -113 38 -75 24 2.5 -293 101 -270 95
3.8 -286 60 -258 57 -253 53 -219 48 -157 31 -104 20 3.8 -405 85 -371 82
5.7 -370 43 -332 42 -328 38 -283 35 -204 21 -137 14 5.7 -524 62 -478 61
7.6 -421 28 -377 30 -374 24 -322 24 -232 11 -156 7 7.6 -597 40 -542 44
9.5 -441 16 -393 21 -391 12 -336 16 -242 1 -163 0 9.5 -625 24 -566 31
BM SF BM SF BM SF BM SF BM SF BM SF BM SF BM SF
m tm t tm t tm t tm t tm t tm t tm t tm t
0.0 0 19 0 34 0 42 0 52 0 18 0 18 0 36 0 35
Mcs = εdiffEcfAcfαcentφ
3250
225
900 150
100
150
250
600
2
Acf = 3250*225 = 731250 mm
therefore, force due to differential shrinkage at the centroid of the deck slab
F = 0.0002*33000*731250*0.43/1000 = 2075 kN
At bottom of girder 0 0
Mcs = εdiffEcfAcfαcentφ
3000
225
900 150
100
150
250
600
2
Acf = 3000*225 = 675000 mm
therefore, force due to differential shrinkage at the centroid of the deck slab
F = 0.0002*33000*675000*0.43/1000 = 1916 kN
At bottom of girder 0 0
h = 1.825 m 0 17.80°
1.68 0.00°
3250
900 225
150
100
150
250
600
Momen
Total C.G of t of
Dist. Of Tempe Stress due to Force force force
Fibre fibre from rature Width of temp. b/w from top abt top
No. top at fibre fibre resistance Force fibres of slab of slab
C.G of composite section from top of the slab (end section) = 0.621 m
C.G of composite section from top of the slab (mid section) = 0.543 m
h = 1.825 m 0 17.80°
1.68 0.00°
3000
900 225
150
100
150
250
600
Momen
Total C.G of t of
Dist. Of Tempe Stress due to Force force force
Fibre fibre from rature Width of temp. b/w from top abt top
No. top at fibre fibre resistance Force fibres of slab of slab
C.G of composite section from top of the slab (end section) = 0.638 m
C.G of composite section from top of the slab (mid section) = 0.560 m
0 -10.60°
0.50 0.00°
h2
0.50 0.00° 1.825
1.33 0.00°
3250
900 225
150
100
150
250
600
Momen
Total C.G of t of
Dist. Of Tempe Stress due to Force force force
Fibre fibre from rature Width of temp. b/w from top abt top
No. top at fibre fibre resistance Force fibres of slab of slab
C.G of composite section from top of the slab (end section) = 0.621 m
C.G of composite section from top of the slab (mid section) = 0.543 m
0 -10.60°
0.50 0.00°
h2
0.50 0.00° 1.825
1.33 0.00°
3000
900 225
150
100
150
250
600
Momen
Total C.G of t of
Dist. Of Tempe Stress due to Force force force
Fibre fibre from rature Width of temp. b/w from top abt top
No. top at fibre fibre resistance Force fibres of slab of slab
C.G of composite section from top of the slab (end section) = 0.638 m
C.G of composite section from top of the slab (mid section) = 0.560 m
3250 3250
1750 1500 1750 1500
(1) 900 (1) 900 225
225
150 300
1825 1825
(6) N.A N.A (6)
0 150
150 150
250 250
600 600
Distance from support 0.0 1.0 1.9 2.5 3.8 5.7 7.6 9.5
No fo Bars Nos. 5 5 5 5 5 5 5 5
Layer
"1" Dia of Bars mm 32 32 32 32 32 32 32 32
No fo Bars Nos. 2 2 2 3 5 5 5 5
Layer
"2" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 132 132 132 132 132 132 132 132
No fo Bars Nos. 0 0 0 0 0 0 3 3
Layer
"3" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 196 196 196 196 196 196 196 196
No fo Bars Nos. 0 0 0 0 0 0 0 0
Layer
"4" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 260 260 260 260 260 260 260 260
No fo Bars Nos. 0 0 0 0 0 0 0 0
Layer
"5" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 324 324 324 324 324 324 324 324
Total Area of reinforcement provided, Ast mm2 5630 5630 5630 6434 8042 8042 10455 10455
Min. area of steel (Ref: Cl.16.5.1.1 of IRC :112-2011) > > > > > > > >
Max. of As,min = 0.26*(fctm/fyk)*bt*d (or) 0.0013btd (or)
2
As,min for crack width mm 1628 1221 814 811 807 807 797 797
Check for minimum area of Reinforcement = 5630 > 1628 Safe Safe Safe Safe Safe Safe Safe Safe
Effective depth, d = 1825-86.28 mm 1739 1739 1739 1733 1725 1725 1703 1703
Width of Web, bw mm 600 450 300 300 300 300 300 300
Fc1 = 0.36fckbf (if N.A lies in flange) N/mm 46800 46800 46800 46800 46800 46800 46800 46800
Fc1 = 0.36fckbw N/mm 8640 6480 4320 4320 4320 4320 4320 4320
(if N.A lies in web)
Fc2 = 0.45fck(bf - bw) N/mm 47700 50400 53100 53100 53100 53100 53100 53100
yf = min(0.15xu + 0.65Df , Df) mm 154 154 154 155 157 157 161 161
Depth of Neutral Axis, xu mm 52.33 52.33 52.33 59.80 74.75 74.75 97.18 97.18
= (0.87fyAst) / (0.36fckbf) < < < < < < < <
Limiting depth of Neutral Axis, xu,max mm 799.94 799.94 799.94 797.18 793.50 793.50 783.38 783.38
Hence, Depth of Neutral Axis, xu mm 52.33 52.33 52.33 59.80 74.75 74.75 97.18 97.18
Hence Neutral Axis Lies in FLANGE FLANGE FLANGE FLANGE FLANGE FLANGE FLANGE FLANGE
Remarks > 0.43 > 0.43 > 0.43 > 0.43 > 0.43 > 0.43 > 0.43 > 0.43
Moment of resistance, MR tm 421 421 421 478 593 593 756 756
= 0.87fy Ast d {1 - (Ast fy)/ (bf d fck)} > > > > > > > >
Ultimate Design Moment at the section, Mu tm 0 130 231 294 405 524 597 625
Check for Moment of Resistance 756>625.1 Safe Safe Safe Safe Safe Safe Safe Safe
where, ν = 0.6[1-fck/310] = 0.523 fcd = αccfck/γm = 17.9 N/mm2 where, αcc = 0.67
Max.allowable shear,
VED ≤ 0.5bwdνfcd = =0.5*600*1739*0.523*17.9/10^4 t 488 366 244 243 242 242 239 239
Check for Max. allowable Shear 133.66419375<488 Safe Safe Safe Safe Safe Safe Safe Safe
Design Shear Resistance of the member = Maximum of VRdc = [0.12 K (80ρ1fck)0.33+0.15σcp]bwd or VRdc = [νmin+0.15σcp]bwd
K = 1 + √(200/d) ≤ 2 = 1+SQRT(200/1739) 1.339 1.339 1.339 1.340 1.341 1.341 1.343 1.343
νmin = 0.031 K3/2fck1/2 =0.031*1.339^(3/2)*40^0.5 0.304 0.304 0.304 0.304 0.304 0.304 0.305 0.305
σcp = NED /Ac < 0.2 fcd = 0.2*αccfck/γm NED = 0 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
ρ1 = Asl /(bwd) = 5630/600/1739 0.0054 0.0072 0.0108 0.0124 0.0155 0.0155 0.0205 0.0205
VRdc=[0.12 K(80ρ1fck)0.33 =(0.12*1.339*(80*0.0054*40)^0
+0.15σcp]bwd .33+0.15*0)*600*1739/10^4 t 43 35 27 28 30 30 33 33
VRdc =
[νmin+0.15σcp]bwd =(0.304+0.15*0)*600*1739/10^ t 32 24 16 16 16 16 16 16
Spacing of reinforcement provided mm 150 150 150 150 150 150 150 150
Check for Spacing of shear reinforcement 150<270 Safe Safe Safe Safe Safe Safe Safe Safe
Area of Shear Reinforcement provided, Asw,prov. mm2 452 452 402 402 226 226 226 157
452/150*0.9*1739*348/10^4*
VRds=(Asw/s)*zfywdcotθ = 1 t 164 164 146 146 81 81 80 56
VRd.max = [αcwbwzν1fcd]/(cotθ+tanθ) where, αcw = 1 (since no axial force) ν1 = 0.6 fcd = αccfck/γm = 17.9 N/mm2
VRd.max = 1*600*0.9*1739*0.6*17.9/(1+1)/10^4 t 504 378 252 251 250 250 247 247
3000 3000
1500 1500 1500 1500
(1) 900 (1) 900 225
225
150 300
1825 1825
(6) N.A N.A (6)
0 150
150 150
250 250
600 600
Distance from support 0.0 1.0 1.9 2.5 3.8 5.7 7.6 9.5
No fo Bars Nos. 5 5 5 5 5 5 5 5
Layer
"1" Dia of Bars mm 32 32 32 32 32 32 32 32
No fo Bars Nos. 2 2 2 3 5 5 5 5
Layer
"2" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 132 132 132 132 132 132 132 132
No fo Bars Nos. 0 0 0 0 0 0 3 3
Layer
"3" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 196 196 196 196 196 196 196 196
No fo Bars Nos. 0 0 0 0 0 0 0 0
Layer
"4" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 260 260 260 260 260 260 260 260
No fo Bars Nos. 0 0 0 0 0 0 0 0
Layer
"5" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 324 324 324 324 324 324 324 324
Total Area of reinforcement provided, Ast mm2 5630 5630 5630 6434 8042 8042 10455 10455
Min. area of steel (Ref: Cl.16.5.1.1 of IRC :112-2011) > > > > > > > >
Max. of As,min = 0.26*(fctm/fyk)*bt*d (or) 0.0013btd (or)
2
As,min for crack width mm 1628 1221 814 811 807 807 797 797
Check for minimum area of Reinforcement = 5630 > 1628 Safe Safe Safe Safe Safe Safe Safe Safe
Effective depth, d = 1825-86.28 mm 1739 1739 1739 1733 1725 1725 1703 1703
Width of Web, bw mm 600 450 300 300 300 300 300 300
Fc1 = 0.36fckbf (if N.A lies in flange) N/mm 43200 43200 43200 43200 43200 43200 43200 43200
Fc1 = 0.36fckbw N/mm 8640 6480 4320 4320 4320 4320 4320 4320
(if N.A lies in web)
Fc2 = 0.45fck(bf - bw) N/mm 43200 45900 48600 48600 48600 48600 48600 48600
yf = min(0.15xu + 0.65Df , Df) mm 155 155 155 156 158 158 162 162
Depth of Neutral Axis, xu mm 56.69 56.69 56.69 64.79 80.98 80.98 105.28 105.28
= (0.87fyAst) / (0.36fckbf) < < < < < < < <
Limiting depth of Neutral Axis, xu,max mm 799.94 799.94 799.94 797.18 793.50 793.50 783.38 783.38
Hence, Depth of Neutral Axis, xu mm 56.69 56.69 56.69 64.79 80.98 80.98 105.28 105.28
Hence Neutral Axis Lies in FLANGE FLANGE FLANGE FLANGE FLANGE FLANGE FLANGE FLANGE
Remarks > 0.43 > 0.43 > 0.43 > 0.43 > 0.43 > 0.43 > 0.43 > 0.43
Moment of resistance, MR tm 420 420 420 478 592 592 755 755
= 0.87fy Ast d {1 - (Ast fy)/ (bf d fck)} > > > > > > > >
Ultimate Design Moment at the section, Mu tm 0 123 214 270 371 478 542 566
Check for Moment of Resistance 755>565.7 Safe Safe Safe Safe Safe Safe Safe Safe
where, ν = 0.6[1-fck/310] = 0.523 fcd = αccfck/γm = 17.9 N/mm2 where, αcc = 0.67
Max.allowable shear,
VED ≤ 0.5bwdνfcd = =0.5*600*1739*0.523*17.9/10^4 t 488 366 244 243 242 242 239 239
Check for Max. allowable Shear 125.7933375<488 Safe Safe Safe Safe Safe Safe Safe Safe
Design Shear Resistance of the member = Maximum of VRdc = [0.12 K (80ρ1fck)0.33+0.15σcp]bwd or VRdc = [νmin+0.15σcp]bwd
K = 1 + √(200/d) ≤ 2 = 1+SQRT(200/1739) 1.339 1.339 1.339 1.340 1.341 1.341 1.343 1.343
3/2 1/2
νmin = 0.031 K fck =0.031*1.339^(3/2)*40^0.5 0.304 0.304 0.304 0.304 0.304 0.304 0.305 0.305
σcp = NED /Ac < 0.2 fcd = 0.2*αccfck/γm NED = 0 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
ρ1 = Asl /(bwd) = 5630/600/1739 0.0054 0.0072 0.0108 0.0124 0.0155 0.0155 0.0205 0.0205
VRdc=[0.12 K(80ρ1fck)0.33 =(0.12*1.339*(80*0.0054*40)^0
+0.15σcp]bwd .33+0.15*0)*600*1739/10^4 t 43 35 27 28 30 30 33 33
VRdc =
[νmin+0.15σcp]bwd =(0.304+0.15*0)*600*1739/10^ t 32 24 16 16 16 16 16 16
Is check for Shear required? Yes Yes Yes Yes Yes Yes Yes No
Spacing of reinforcement provided mm 150 150 150 150 150 150 150 150
Check for Spacing of shear reinforcement 150<296 Safe Safe Safe Safe Safe Safe Safe Safe
Area of Shear Reinforcement provided, Asw,prov. mm2 452 452 402 402 226 226 226 157
452/150*0.9*1739*348/10^4*
VRds=(Asw/s)*zfywdcotθ = 1 t 164 164 146 146 81 81 80 56
VRd.max = [αcwbwzν1fcd]/(cotθ+tanθ) where, αcw = 1 (since no axial force) ν1 = 0.6 fcd = αccfck/γm = 17.9 N/mm2
VRd.max = 1*600*0.9*1739*0.6*17.9/(1+1)/10^4 t 504 378 252 251 250 250 247 247
150 300
0 150
150 150
250 250
600 600
Distance from support 0.0 1.0 1.9 2.5 3.8 5.7 7.6 9.5
No fo Bars Nos. 5 5 5 5 5 5 5 5
Layer
"1" Dia of Bars mm 32 32 32 32 32 32 32 32
No fo Bars Nos. 2 2 2 3 5 5 5 5
Layer
"2" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 132 132 132 132 132 132 132 132
No fo Bars Nos. 0 0 0 0 0 0 3 3
Layer
"3" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 196 196 196 196 196 196 196 196
No fo Bars Nos. 0 0 0 0 0 0 0 0
Layer
"4" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 260 260 260 260 260 260 260 260
No fo Bars Nos. 0 0 0 0 0 0 0 0
Layer
"5" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 324 324 324 324 324 324 324 324
Total Area of reinforcement provided, Ast mm2 5630 5630 5630 6434 8042 8042 10455 10455
Min. area of steel (Ref: Cl.16.5.1.1 of IRC :112-2011) > > > > > > > >
Max. of As,min = 0.26*(fctm/fyk)*bt*d (or) 0.0013btd (or)
2
As,min for crack width mm 1417 1063 709 706 702 702 692 692
Check for minimum area of Reinforcement = 5630 > 1417 Safe Safe Safe Safe Safe Safe Safe Safe
Effective depth, d = 1600-86.28 mm 1514 1514 1514 1508 1500 1500 1478 1478
Width of Web, bw mm 600 450 300 300 300 300 300 300
Fc1 = 0.36fckbf (if N.A lies in flange) N/mm 12960 12960 12960 12960 12960 12960 12960 12960
Fc1 = 0.36fckbw N/mm 8640 6480 4320 4320 4320 4320 4320 4320
(if N.A lies in web)
Fc2 = 0.45fck(bf - bw) N/mm 5400 8100 10800 10800 10800 10800 10800 10800
yf = min(0.15xu + 0.65Df , Df) mm 128 130 133 142 150 150 150 150
Depth of Neutral Axis, xu mm 203.44 215.63 235.03 293.90 434.78 434.78 677.76 677.76
= (0.87fyAst - 0.45fck(bf -bw)yf) / (0.36fckbw) < < < < < < < <
Limiting depth of Neutral Axis, xu,max mm 696.44 696.44 696.44 693.68 690.00 690.00 679.88 679.88
Hence, Depth of Neutral Axis, xu mm 203.44 215.63 235.03 293.90 434.78 434.78 677.76 677.76
Hence Neutral Axis Lies in WEB WEB WEB WEB WEB WEB WEB WEB
Remarks > 0.43 > 0.43 > 0.43 > 0.43 < 0.43 < 0.43 < 0.43 < 0.43
Moment of resistance, MR tm 351 351 351 396 478 478 577 577
= 0.36 fck bw xu (d-0.42xu )+0.45fck (bf -bw) yf (d-yf /2) > > > > > > > >
Check for Moment of Resistance 577>80 Safe Safe Safe Safe Safe Safe Safe Safe
Permissible Comp. stress in Concrete at top,
fc,perm = 19.20 N/mm2 0.0 0.9 1.5 1.7 1.9 2.5 2.4 2.5
(0.45fck bw 0.43xu + 2/3*0.45fck bw*0.57xu) * (d - 0.42xu) +
0.45fck(bf-bw)*yf(d-yf/2) = Safe Safe Safe Safe Safe Safe Safe Safe
150 300
0 150
150 150
250 250
600 600
Distance from support 0.0 1.0 1.9 2.5 3.8 5.7 7.6 9.5
No fo Bars Nos. 5 5 5 5 5 5 5 5
Layer
"1" Dia of Bars mm 32 32 32 32 32 32 32 32
No fo Bars Nos. 2 2 2 3 5 5 5 5
Layer
"2" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 132 132 132 132 132 132 132 132
No fo Bars Nos. 0 0 0 0 0 0 3 3
Layer
"3" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 196 196 196 196 196 196 196 196
No fo Bars Nos. 0 0 0 0 0 0 0 0
Layer
"4" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 260 260 260 260 260 260 260 260
No fo Bars Nos. 0 0 0 0 0 0 0 0
Layer
"5" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 324 324 324 324 324 324 324 324
Total Area of reinforcement provided, Ast mm2 5630 5630 5630 6434 8042 8042 10455 10455
Min. area of steel (Ref: Cl.16.5.1.1 of IRC :112-2011) > > > > > > > >
Max. of As,min = 0.26*(fctm/fyk)*bt*d (or) 0.0013btd (or)
2
As,min for crack width mm 1417 1063 709 706 702 702 692 692
Check for minimum area of Reinforcement = 5630 > 1417 Safe Safe Safe Safe Safe Safe Safe Safe
Effective depth, d = 1600-86.28 mm 1514 1514 1514 1508 1500 1500 1478 1478
Width of Web, bw mm 600 450 300 300 300 300 300 300
Fc1 = 0.36fckbf (if N.A lies in flange) N/mm 12960 12960 12960 12960 12960 12960 12960 12960
Fc1 = 0.36fckbw N/mm 8640 6480 4320 4320 4320 4320 4320 4320
(if N.A lies in web)
Fc2 = 0.45fck(bf - bw) N/mm 5400 8100 10800 10800 10800 10800 10800 10800
yf = min(0.15xu + 0.65Df , Df) mm 128 130 133 142 150 150 150 150
Depth of Neutral Axis, xu mm 203.44 215.63 235.03 293.90 434.78 434.78 677.76 677.76
= (0.87fyAst - 0.45fck(bf -bw)yf) / (0.36fckbw) < < < < < < < <
Limiting depth of Neutral Axis, xu,max mm 696.44 696.44 696.44 693.68 690.00 690.00 679.88 679.88
Hence, Depth of Neutral Axis, xu mm 203.44 215.63 235.03 293.90 434.78 434.78 677.76 677.76
Hence Neutral Axis Lies in WEB WEB WEB WEB WEB WEB WEB WEB
Remarks > 0.43 > 0.43 > 0.43 > 0.43 < 0.43 < 0.43 < 0.43 < 0.43
Moment of resistance, MR tm 351 351 351 396 478 478 577 577
= 0.36 fck bw xu (d-0.42xu )+0.45fck (bf -bw) yf (d-yf /2) > > > > > > > >
Check for Moment of Resistance 577>80 Safe Safe Safe Safe Safe Safe Safe Safe
Permissible Comp. stress in Concrete at top,
fc,perm = 19.20 N/mm2 0.0 0.9 1.5 1.7 1.9 2.5 2.4 2.5
(0.45fck bw 0.43xu + 2/3*0.45fck bw*0.57xu) * (d - 0.42xu) +
0.45fck(bf-bw)*yf(d-yf/2) = Safe Safe Safe Safe Safe Safe Safe Safe
150 300
0 150
150 150
250 250
600 600
Distance from support 0.0 1.0 1.9 2.5 3.8 5.7 7.6 9.5
No fo Bars Nos. 5 5 5 5 5 5 5 5
Layer
"1" Dia of Bars mm 32 32 32 32 32 32 32 32
No fo Bars Nos. 2 2 2 3 5 5 5 5
Layer
"2" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 132 132 132 132 132 132 132 132
No fo Bars Nos. 0 0 0 0 0 0 3 3
Layer
"3" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 196 196 196 196 196 196 196 196
No fo Bars Nos. 0 0 0 0 0 0 0 0
Layer
"4" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 260 260 260 260 260 260 260 260
No fo Bars Nos. 0 0 0 0 0 0 0 0
Layer
"5" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 324 324 324 324 324 324 324 324
Total Area of reinforcement provided, Ast mm2 5630 5630 5630 6434 8042 8042 10455 10455
Min. area of steel (Ref: Cl.16.5.1.1 of IRC :112-2011) > > > > > > > >
Max. of As,min = 0.26*(fctm/fyk)*bt*d (or) 0.0013btd (or)
2
As,min for crack width mm 1417 1063 709 706 702 702 692 692
Check for minimum area of Reinforcement = 5630 > 1417 Safe Safe Safe Safe Safe Safe Safe Safe
Effective depth, d = -86.28 mm 1514 1514 1514 1508 1500 1500 1478 1478
Width of Web, bw mm 600 450 300 300 300 300 300 300
Fc1 = 0.36fckbf (if N.A lies in flange) N/mm 12960 12960 12960 12960 12960 12960 12960 12960
Fc1 = 0.36fckbw N/mm 8640 6480 4320 4320 4320 4320 4320 4320
(if N.A lies in web)
Fc2 = 0.45fck(bf - bw) N/mm 5400 8100 10800 10800 10800 10800 10800 10800
yf = min(0.15xu + 0.65Df , Df) mm 128 130 133 142 150 150 150 150
Depth of Neutral Axis, xu mm 203.44 215.63 235.03 293.90 434.78 434.78 677.76 677.76
= (0.87fyAst - 0.45fck(bf -bw)yf) / (0.36fckbw) < < < < < < < <
Limiting depth of Neutral Axis, xu,max mm 696.44 696.44 696.44 693.68 690.00 690.00 679.88 679.88
Hence, Depth of Neutral Axis, xu mm 203.44 215.63 235.03 293.90 434.78 434.78 677.76 677.76
Hence Neutral Axis Lies in WEB WEB WEB WEB WEB WEB WEB WEB
Remarks > 0.43 > 0.43 > 0.43 > 0.43 < 0.43 < 0.43 < 0.43 < 0.43
Moment of resistance, MR tm 351 351 351 396 478 478 577 577
= 0.36 fck bw xu (d-0.42xu )+0.45fck (bf -bw) yf (d-yf /2) > > > > > > > >
Check for Moment of Resistance 577>166 Safe Safe Safe Safe Safe Safe Safe Safe
Permissible Comp. stress in Concrete at top,
fc,perm = 19.20 N/mm2 0.0 1.7 3.1 3.4 4.0 5.2 4.9 5.1
(0.45fck bw 0.43xu + 2/3*0.45fck bw*0.57xu) * (d - 0.42xu) +
0.45fck(bf-bw)*yf(d-yf/2) = Safe Safe Safe Safe Safe Safe Safe Safe
150 300
0 150
150 150
250 250
600 600
Distance from support 0.0 1.0 1.9 2.5 3.8 5.7 7.6 9.5
No fo Bars Nos. 5 5 5 5 5 5 5 5
Layer
"1" Dia of Bars mm 32 32 32 32 32 32 32 32
No fo Bars Nos. 2 2 2 3 5 5 5 5
Layer
"2" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 132 132 132 132 132 132 132 132
No fo Bars Nos. 0 0 0 0 0 0 3 3
Layer
"3" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 196 196 196 196 196 196 196 196
No fo Bars Nos. 0 0 0 0 0 0 0 0
Layer
"4" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 260 260 260 260 260 260 260 260
No fo Bars Nos. 0 0 0 0 0 0 0 0
Layer
"5" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 324 324 324 324 324 324 324 324
Total Area of reinforcement provided, Ast mm2 5630 5630 5630 6434 8042 8042 10455 10455
Min. area of steel (Ref: Cl.16.5.1.1 of IRC :112-2011) > > > > > > > >
Max. of As,min = 0.26*(fctm/fyk)*bt*d (or) 0.0013btd (or)
2
As,min for crack width mm 1417 1063 709 706 702 702 692 692
Check for minimum area of Reinforcement = 5630 > 1417 Safe Safe Safe Safe Safe Safe Safe Safe
Effective depth, d = -86.28 mm 1514 1514 1514 1508 1500 1500 1478 1478
Width of Web, bw mm 600 450 300 300 300 300 300 300
Fc1 = 0.36fckbf (if N.A lies in flange) N/mm 12960 12960 12960 12960 12960 12960 12960 12960
Fc1 = 0.36fckbw N/mm 8640 6480 4320 4320 4320 4320 4320 4320
(if N.A lies in web)
Fc2 = 0.45fck(bf - bw) N/mm 5400 8100 10800 10800 10800 10800 10800 10800
yf = min(0.15xu + 0.65Df , Df) mm 128 130 133 142 150 150 150 150
Depth of Neutral Axis, xu mm 203.44 215.63 235.03 293.90 434.78 434.78 677.76 677.76
= (0.87fyAst - 0.45fck(bf -bw)yf) / (0.36fckbw) < < < < < < < <
Limiting depth of Neutral Axis, xu,max mm 696.44 696.44 696.44 693.68 690.00 690.00 679.88 679.88
Hence, Depth of Neutral Axis, xu mm 203.44 215.63 235.03 293.90 434.78 434.78 677.76 677.76
Hence Neutral Axis Lies in WEB WEB WEB WEB WEB WEB WEB WEB
Remarks > 0.43 > 0.43 > 0.43 > 0.43 < 0.43 < 0.43 < 0.43 < 0.43
Moment of resistance, MR tm 351 351 351 396 478 478 577 577
= 0.36 fck bw xu (d-0.42xu )+0.45fck (bf -bw) yf (d-yf /2) > > > > > > > >
Check for Moment of Resistance 577>159 Safe Safe Safe Safe Safe Safe Safe Safe
Permissible Comp. stress in Concrete at top,
fc,perm = 19.20 N/mm2 0.0 1.6 3.0 3.3 3.8 5.0 4.7 4.9
(0.45fck bw 0.43xu + 2/3*0.45fck bw*0.57xu) * (d - 0.42xu) +
0.45fck(bf-bw)*yf(d-yf/2) = Safe Safe Safe Safe Safe Safe Safe Safe
3250 3250
1750 1500 1750 1500
(1) 900 (1) 900 225
225
150 300
1825 1825
(6) N.A N.A (6)
0 150
150 150
250 250
600 600
Distance from support 0.0 1.0 1.9 2.5 3.8 5.7 7.6 9.5
No fo Bars Nos. 5 5 5 5 5 5 5 5
Layer
"1" Dia of Bars mm 32 32 32 32 32 32 32 32
No fo Bars Nos. 2 2 2 3 5 5 5 5
Layer
"2" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 132 132 132 132 132 132 132 132
No fo Bars Nos. 0 0 0 0 0 0 3 3
Layer
"3" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 196 196 196 196 196 196 196 196
No fo Bars Nos. 0 0 0 0 0 0 0 0
Layer
"4" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 260 260 260 260 260 260 260 260
No fo Bars Nos. 0 0 0 0 0 0 0 0
Layer
"5" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 324 324 324 324 324 324 324 324
Total Area of reinforcement provided, Ast mm2 5630 5630 5630 6434 8042 8042 10455 10455
Min. area of steel (Ref: Cl.16.5.1.1 of IRC :112-2011) > > > > > > > >
Max. of As,min = 0.26*(fctm/fyk)*bt*d (or) 0.0013btd (or)
2
As,min for crack width mm 1628 1221 814 811 807 807 797 797
Check for minimum area of Reinforcement = 5630 > 1628 Safe Safe Safe Safe Safe Safe Safe Safe
Effective depth, d = 1825-86.28 mm 1739 1739 1739 1733 1725 1725 1703 1703
Width of Web, bw mm 600 450 300 300 300 300 300 300
Fc1 = 0.36fckbf (if N.A lies in flange) N/mm 46800 46800 46800 46800 46800 46800 46800 46800
Fc1 = 0.36fckbw N/mm 8640 6480 4320 4320 4320 4320 4320 4320
(if N.A lies in web)
Fc2 = 0.45fck(bf - bw) N/mm 47700 50400 53100 53100 53100 53100 53100 53100
yf = min(0.15xu + 0.65Df , Df) mm 154 154 154 155 157 157 161 161
Depth of Neutral Axis, xu mm 52.33 52.33 52.33 59.80 74.75 74.75 97.18 97.18
= (0.87fyAst) / (0.36fckbf) < < < < < < < <
Limiting depth of Neutral Axis, xu,max mm 799.94 799.94 799.94 797.18 793.50 793.50 783.38 783.38
Hence, Depth of Neutral Axis, xu mm 52.33 52.33 52.33 59.80 74.75 74.75 97.18 97.18
Hence Neutral Axis Lies in FLANGE FLANGE FLANGE FLANGE FLANGE FLANGE FLANGE FLANGE
Remarks > 0.43 > 0.43 > 0.43 > 0.43 > 0.43 > 0.43 > 0.43 > 0.43
Moment of resistance, MR tm 421 421 421 478 593 593 756 756
= 0.87fy Ast d {1 - (Ast fy)/ (bf d fck)} > > > > > > > >
Design Moment at the section, M (Rare Combination) tm 0 92 163 207 286 370 421 441
Check for Moment of Resistance 756>441 Safe Safe Safe Safe Safe Safe Safe Safe
Permissible Comp. stress in Concrete at top,
fc,perm = 19.20 N/mm2 0.0 3.2 5.6 6.2 7.0 9.0 8.0 8.4
fc = M / (bf xu* (d - 0.42xu)) Safe Safe Safe Safe Safe Safe Safe Safe
Permissible Tensile stress in Steel at bottom,
ft,perm = -400.00 N/mm2 0 -95 -169 -188 -210 -272 -242 -254
fs = M / (Ast* (d - 0.42xu)) Safe Safe Safe Safe Safe Safe Safe Safe
Design Moment at the section, M (Frequent
Combination) tm 0 81 145 184 253 328 374 391
Check for Moment of Resistance 756>391 Safe Safe Safe Safe Safe Safe Safe Safe
Permissible Comp. stress in Concrete at top,
2
fc,perm = 19.20 N/mm 0.0 2.8 5.0 5.5 6.1 8.0 7.1 7.4
fc = M / (bf xu* (d - 0.42xu)) Safe Safe Safe Safe Safe Safe Safe Safe
Permissible Tensile stress in Steel at bottom,
ft,perm = -400.00 N/mm2 0 -84 -150 -167 -186 -241 -215 -225
fs = M / (Ast* (d - 0.42xu)) Safe Safe Safe Safe Safe Safe Safe Safe
Design Moment at the section, M (Quasi-Permanent
Combination) tm 0 50 90 113 157 204 232 242
Check for Moment of Resistance 756>242 Safe Safe Safe Safe Safe Safe Safe Safe
fc = M / (bf xu* (d - 0.42xu)) Safe Safe Safe Safe Safe Safe Safe Safe
Permissible Tensile stress in Steel at bottom,
2
ft,perm = -400.00 N/mm 0 -52 -93 -103 -115 -150 -134 -139
fs = M / (Ast* (d - 0.42xu)) Safe Safe Safe Safe Safe Safe Safe Safe
3000 3000
1500 1500 1500 1500
(1) 900 (1) 900 225
225
150 300
1825 1825
(6) N.A N.A (6)
0 150
150 150
250 250
600 600
Distance from support 0.0 1.0 1.9 2.5 3.8 5.7 7.6 9.5
No fo Bars Nos. 5 5 5 5 5 5 5 5
Layer
"1" Dia of Bars mm 32 32 32 32 32 32 32 32
No fo Bars Nos. 2 2 2 3 5 5 5 5
Layer
"2" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 132 132 132 132 132 132 132 132
No fo Bars Nos. 0 0 0 0 0 0 3 3
Layer
"3" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 196 196 196 196 196 196 196 196
No fo Bars Nos. 0 0 0 0 0 0 0 0
Layer
"4" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 260 260 260 260 260 260 260 260
No fo Bars Nos. 0 0 0 0 0 0 0 0
Layer
"5" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 324 324 324 324 324 324 324 324
Total Area of reinforcement provided, Ast mm2 5630 5630 5630 6434 8042 8042 10455 10455
Min. area of steel (Ref: Cl.16.5.1.1 of IRC :112-2011) > > > > > > > >
Max. of As,min = 0.26*(fctm/fyk)*bt*d (or) 0.0013btd (or)
2
As,min for crack width mm 1628 1221 814 811 807 807 797 797
Check for minimum area of Reinforcement = 5630 > 1628 Safe Safe Safe Safe Safe Safe Safe Safe
Effective depth, d = 1825-86.28 mm 1739 1739 1739 1733 1725 1725 1703 1703
Width of Web, bw mm 600 450 300 300 300 300 300 300
Fc1 = 0.36fckbf (if N.A lies in flange) N/mm 43200 43200 43200 43200 43200 43200 43200 43200
Fc1 = 0.36fckbw N/mm 8640 6480 4320 4320 4320 4320 4320 4320
(if N.A lies in web)
Fc2 = 0.45fck(bf - bw) N/mm 43200 45900 48600 48600 48600 48600 48600 48600
yf = min(0.15xu + 0.65Df , Df) mm 155 155 155 156 158 158 162 162
Depth of Neutral Axis, xu mm 56.69 56.69 56.69 64.79 80.98 80.98 105.28 105.28
= (0.87fyAst) / (0.36fckbf) < < < < < < < <
Limiting depth of Neutral Axis, xu,max mm 799.94 799.94 799.94 797.18 793.50 793.50 783.38 783.38
Hence, Depth of Neutral Axis, xu mm 56.69 56.69 56.69 64.79 80.98 80.98 105.28 105.28
Hence Neutral Axis Lies in FLANGE FLANGE FLANGE FLANGE FLANGE FLANGE FLANGE FLANGE
Remarks > 0.43 > 0.43 > 0.43 > 0.43 > 0.43 > 0.43 > 0.43 > 0.43
Moment of resistance, MR tm 420 420 420 478 592 592 755 755
= 0.87fy Ast d {1 - (Ast fy)/ (bf d fck)} > > > > > > > >
Design Moment at the section, M (Rare Combination) tm 0 85 148 187 258 332 377 393
Check for Moment of Resistance 755>393 Safe Safe Safe Safe Safe Safe Safe Safe
Permissible Comp. stress in Concrete at top,
fc,perm = 19.20 N/mm2 0.0 2.9 5.1 5.6 6.3 8.1 7.2 7.5
fc = M / (bf xu* (d - 0.42xu)) Safe Safe Safe Safe Safe Safe Safe Safe
Permissible Tensile stress in Steel at bottom,
ft,perm = -400.00 N/mm2 0 -88 -153 -170 -190 -244 -217 -227
fs = M / (Ast* (d - 0.42xu)) Safe Safe Safe Safe Safe Safe Safe Safe
Design Moment at the section, M (Frequent
Combination) tm 0 72 126 159 219 283 322 336
Check for Moment of Resistance 755>336 Safe Safe Safe Safe Safe Safe Safe Safe
Permissible Comp. stress in Concrete at top,
2
fc,perm = 19.20 N/mm 0.0 2.5 4.3 4.8 5.3 6.9 6.1 6.4
fc = M / (bf xu* (d - 0.42xu)) Safe Safe Safe Safe Safe Safe Safe Safe
Permissible Tensile stress in Steel at bottom,
ft,perm = -400.00 N/mm2 0 -75 -130 -145 -161 -208 -186 -194
fs = M / (Ast* (d - 0.42xu)) Safe Safe Safe Safe Safe Safe Safe Safe
Design Moment at the section, M (Quasi-Permanent
Combination) tm 0 33 59 75 104 137 156 163
Check for Moment of Resistance 755>163 Safe Safe Safe Safe Safe Safe Safe Safe
fc = M / (bf xu* (d - 0.42xu)) Safe Safe Safe Safe Safe Safe Safe Safe
Permissible Tensile stress in Steel at bottom,
2
ft,perm = -400.00 N/mm 0 -34 -61 -68 -76 -101 -90 -94
fs = M / (Ast* (d - 0.42xu)) Safe Safe Safe Safe Safe Safe Safe Safe
3250 3250
1750 1500 1750 1500
(1) 900 (1) 900 225
225
150 300
1825 1825
(6) N.A N.A (6)
0 150
150 150
250 250
600 600
Distance from support 0.0 1.0 1.9 2.5 3.8 5.7 7.6 9.5
No fo Bars Nos. 5 5 5 5 5 5 5 5
Layer
"1" Dia of Bars mm 32 32 32 32 32 32 32 32
No fo Bars Nos. 2 2 2 3 5 5 5 5
Layer
"2" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 132 132 132 132 132 132 132 132
No fo Bars Nos. 0 0 0 0 0 0 3 3
Layer
"3" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 196 196 196 196 196 196 196 196
No fo Bars Nos. 0 0 0 0 0 0 0 0
Layer
"4" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 260 260 260 260 260 260 260 260
No fo Bars Nos. 0 0 0 0 0 0 0 0
Layer
"5" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 324 324 324 324 324 324 324 324
Total Area of reinforcement provided, Ast mm2 5630 5630 5630 6434 8042 8042 10455 10455
Min. area of steel (Ref: Cl.16.5.1.1 of IRC :112-2011) > > > > > > > >
Max. of As,min = 0.26*(fctm/fyk)*bt*d (or) 0.0013btd (or)
2
As,min for crack width mm 1628 1221 814 811 807 807 797 797
Check for minimum area of Reinforcement = 5630 > 1628 Safe Safe Safe Safe Safe Safe Safe Safe
Effective depth, d = 1825-86.28 mm 1739 1739 1739 1733 1725 1725 1703 1703
Width of Web, bw mm 600 450 300 300 300 300 300 300
Fc1 = 0.36fckbf (if N.A lies in flange) N/mm 46800 46800 46800 46800 46800 46800 46800 46800
Fc1 = 0.36fckbw N/mm 8640 6480 4320 4320 4320 4320 4320 4320
(if N.A lies in web)
Fc2 = 0.45fck(bf - bw) N/mm 47700 50400 53100 53100 53100 53100 53100 53100
yf = min(0.15xu + 0.65Df , Df) mm 154 154 154 155 157 157 161 161
Depth of Neutral Axis, xu mm 52.33 52.33 52.33 59.80 74.75 74.75 97.18 97.18
= (0.87fyAst) / (0.36fckbf) < < < < < < < <
Limiting depth of Neutral Axis, xu,max mm 799.94 799.94 799.94 797.18 793.50 793.50 783.38 783.38
Hence, Depth of Neutral Axis, xu mm 52.33 52.33 52.33 59.80 74.75 74.75 97.18 97.18
Hence Neutral Axis Lies in FLANGE FLANGE FLANGE FLANGE FLANGE FLANGE FLANGE FLANGE
Remarks > 0.43 > 0.43 > 0.43 > 0.43 > 0.43 > 0.43 > 0.43 > 0.43
Design Moment at the section, DL+SIDL tm 0 50 90 113 157 204 232 242
Comp. stress in Concrete at top N/mm2 0.0 1.7 3.1 3.4 3.8 5.0 4.4 4.6
Tensile stress in Steel at bottom N/mm2 0 -52 -93 -103 -115 -150 -134 -139
Comp. stress in Concrete at top N/mm2 0.0 1.4 2.5 2.8 3.1 4.0 3.6 3.8
Tensile stress in Steel at bottom N/mm2 0 -43 -76 -86 -95 -122 -109 -115
Stress at top of slab N/mm2 -0.66 -0.66 -0.38 -0.38 -0.38 -0.38 -0.38 -0.38
Differential Shrinkage
Stress at bottom steel N/mm2 -0.86 -0.86 -1.06 -1.06 -1.06 -1.06 -1.06 -1.06
Positive Temperature Stress at top of slab N/mm2 4.12 4.06 4.00 4.00 4.00 4.00 4.00 4.00
Difference
Stress at bottom steel N/mm2 2.19 2.10 2.00 2.00 2.00 2.00 2.00 2.00
Negative Temperature Stress at top of slab N/mm2 -0.69 -0.61 -0.53 -0.53 -0.53 -0.53 -0.53 -0.53
Difference
Stress at bottom steel N/mm2 -3.38 -3.11 -2.84 -2.84 -2.84 -2.84 -2.84 -2.84
Rare Combination Perm. Comp. stress in concrete = 19.2MPa Perm. Tensile stress= -3.00MPa Perm. Tensile Stress in Steel = -400MPa
Case (i) 1.00*(DL+SIDL) + + 1.00 *(LL) + 1.00 *(Diff. Shrinkage) + 0.60 *(+ve Temp. Diff.)
Stress at top of slab N/mm2 1.8 4.9 7.6 8.3 9.0 11.0 10.0 10.4
Leading Live Load
Stress at bottom steel N/mm2 0.5 -94.8 -168.5 -188.2 -209.8 -271.5 -242.1 -253.6
Case (ii) 1.00*(DL+SIDL) + + 1.00 *(LL) + 0.75 *(Diff. Shrinkage) + 1.00 *(+ve Temp. Diff.)
2
Stress at top of slab N/mm 3.6 6.7 9.3 10.0 10.7 12.7 11.7 12.1
Leading Thermal loads
Case (iii) 1.00*(DL+SIDL) + + 1.00 *(LL) + 1.00 *(Diff. Shrinkage) + 0.60 *(-ve Temp. Diff.)
Stress at top of slab N/mm2 -1.1 2.1 4.9 5.5 6.3 8.3 7.3 7.7
Leading Live Load
Stress at bottom steel N/mm2 -2.9 -97.9 -171.4 -191.1 -212.7 -274.4 -245.0 -256.5
Case (iv) 1.00*(DL+SIDL) + + 1.00 *(LL) + 0.75 *(Diff. Shrinkage) + 1.00 *(-ve Temp. Diff.)
Stress at top of slab N/mm2 -1.2 6.7 9.3 10.0 10.7 12.7 11.7 12.1
Leading Thermal loads
2
Stress at bottom steel N/mm -4.0 -93.7 -167.4 -187.2 -208.8 -270.4 -241.0 -252.6
3000 3000
1500 1500 1500 1500
(1) 900 (1) 900 225
225
150 300
1825 1825
(6) N.A N.A (6)
0 150
150 150
250 250
600 600
Distance from support 0.0 1.0 1.9 2.5 3.8 5.7 7.6 9.5
No fo Bars Nos. 5 5 5 5 5 5 5 5
Layer
"1" Dia of Bars mm 32 32 32 32 32 32 32 32
No fo Bars Nos. 2 2 2 3 5 5 5 5
Layer
"2" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 132 132 132 132 132 132 132 132
No fo Bars Nos. 0 0 0 0 0 0 3 3
Layer
"3" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 196 196 196 196 196 196 196 196
No fo Bars Nos. 0 0 0 0 0 0 0 0
Layer
"4" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 260 260 260 260 260 260 260 260
No fo Bars Nos. 0 0 0 0 0 0 0 0
Layer
"5" Dia of Bars mm 32 32 32 32 32 32 32 32
Effective cover from base mm 324 324 324 324 324 324 324 324
Total Area of reinforcement provided, Ast mm2 5630 5630 5630 6434 8042 8042 10455 10455
Min. area of steel (Ref: Cl.16.5.1.1 of IRC :112-2011) > > > > > > > >
Max. of As,min = 0.26*(fctm/fyk)*bt*d (or) 0.0013btd (or)
2
As,min for crack width mm 1628 1221 814 811 807 807 797 797
Check for minimum area of Reinforcement = 5630 > 1628 Safe Safe Safe Safe Safe Safe Safe Safe
Effective depth, d = 1825-86.28 mm 1739 1739 1739 1733 1725 1725 1703 1703
Width of Web, bw mm 600 450 300 300 300 300 300 300
Fc1 = 0.36fckbf (if N.A lies in flange) N/mm 43200 43200 43200 43200 43200 43200 43200 43200
Fc1 = 0.36fckbw N/mm 8640 6480 4320 4320 4320 4320 4320 4320
(if N.A lies in web)
Fc2 = 0.45fck(bf - bw) N/mm 43200 45900 48600 48600 48600 48600 48600 48600
yf = min(0.15xu + 0.65Df , Df) mm 155 155 155 156 158 158 162 162
Depth of Neutral Axis, xu mm 56.69 56.69 56.69 64.79 80.98 80.98 105.28 105.28
= (0.87fyAst) / (0.36fckbf) < < < < < < < <
Limiting depth of Neutral Axis, xu,max mm 799.94 799.94 799.94 797.18 793.50 793.50 783.38 783.38
Hence, Depth of Neutral Axis, xu mm 56.69 56.69 56.69 64.79 80.98 80.98 105.28 105.28
Hence Neutral Axis Lies in FLANGE FLANGE FLANGE FLANGE FLANGE FLANGE FLANGE FLANGE
Remarks > 0.43 > 0.43 > 0.43 > 0.43 > 0.43 > 0.43 > 0.43 > 0.43
Comp. stress in Concrete at top N/mm2 0.0 1.1 2.0 2.3 2.5 3.3 3.0 3.1
Tensile stress in Steel at bottom N/mm2 0 -34 -61 -68 -76 -101 -90 -94
Comp. stress in Concrete at top N/mm2 0.0 1.8 3.1 3.4 3.7 4.7 4.2 4.4
Tensile stress in Steel at bottom N/mm2 0 -54 -93 -103 -113 -143 -127 -133
Stress at top of slab N/mm2 -0.70 -0.70 -0.42 -0.42 -0.42 -0.42 -0.42 -0.42
Differential Shrinkage
Stress at bottom steel N/mm2 -0.89 -0.89 -1.08 -1.08 -1.08 -1.08 -1.08 -1.08
Positive Temperature Stress at top of slab N/mm2 4.17 4.11 4.05 4.05 4.05 4.05 4.05 4.05
Difference
Stress at bottom steel N/mm2 2.16 2.06 1.97 1.97 1.97 1.97 1.97 1.97
Negative Temperature Stress at top of slab N/mm2 -0.77 -0.69 -0.60 -0.60 -0.60 -0.60 -0.60 -0.60
Difference
Stress at bottom steel N/mm2 -3.34 -3.08 -2.81 -2.81 -2.81 -2.81 -2.81 -2.81
Rare Combination Perm. Comp. stress in concrete = 19.20MPa Perm. Tensile stress= -3.00MPa Perm. Tensile Stress in Steel = -400MPa
Case (i) 1.00*(DL+SIDL) + + 1.00 *(LL) + 1.00 *(Diff. Shrinkage) + 0.60 *(+ve Temp. Diff.)
Stress at top of slab N/mm2 1.8 4.7 7.1 7.7 8.3 10.1 9.2 9.5
Leading Live Load
Stress at bottom steel N/mm2 0.4 -87.7 -154.2 -171.2 -189.6 -244.0 -217.3 -226.5
Case (ii) 1.00*(DL+SIDL) + + 1.00 *(LL) + 0.75 *(Diff. Shrinkage) + 1.00 *(+ve Temp. Diff.)
2
Stress at top of slab N/mm 3.7 6.5 8.8 9.4 10.0 11.8 10.9 11.2
Leading Thermal loads
Case (iii) 1.00*(DL+SIDL) + + 1.00 *(LL) + 1.00 *(Diff. Shrinkage) + 0.60 *(-ve Temp. Diff.)
Stress at top of slab N/mm2 -1.2 1.8 4.3 4.9 5.5 7.3 6.4 6.7
Leading Live Load
Stress at bottom steel N/mm2 -2.9 -90.8 -157.1 -174.1 -192.5 -246.9 -220.1 -229.4
Case (iv) 1.00*(DL+SIDL) + + 1.00 *(LL) + 0.75 *(Diff. Shrinkage) + 1.00 *(-ve Temp. Diff.)
Stress at top of slab N/mm2 -1.3 6.5 8.8 9.4 10.0 11.8 10.9 11.2
Leading Thermal loads
2
Stress at bottom steel N/mm -4.0 -86.6 -153.1 -170.1 -188.6 -243.0 -216.2 -225.4
kc = 0.4(1-(σc/(k1(h/h*)fct,eff))) ≤ 1
kc = coefficient = 0.4
1.269 N/mm2
542.6
1825 N.A
1032.4 1282.4
-2.414
250
-2.999 N/mm2
600
kc = 0.9(Fcr/(Act*fct,eff)) ≥ 0.5
kc = MAX(0.9*677/75000/3,0.5) = 0.5
k = coefficient = 1
2
As.min = 0.5*1*3*75000/500 = 225 mm
Clear cover, c = 40 mm
Effective diameter = 32 mm
αe = Es/Ecm = 6.06
s ≤ 5(c+φ/2) = 280 mm
Wk = 1241*0.0011576 = 1.44 mm
Permissible crack width (as per table 12.1 of IRC :112-2011) = 0.3 mm
Sr,max ={ (3.4c+0.17φ)/ρp,eff }
387 209 209 197 197
cl. 12.3.4 (3) of IRC :112-2011
kt 0.5 0.5 0.5 0.5 0.5
fct,eff 2.90 2.90 2.90 2.90 2.90
Es 200000 200000 200000 200000 200000
Ecm 32000 32000 32000 32000 32000
ae = Es / Ecm 6.25 6.25 6.25 6.25 6.25
(esm-ecm)=(ssc-kt fct,eff(1+ae rp,eff)/rp,eff 0.0000 0.0004 0.0012 0.0011 0.0012
cl. 12.3.4 (2) of IRC :112-2011
Wk = Sr,max (esm - ecm ) 0.00 0.08 0.27 0.24 0.25
cl. 12.3.4 (1) of IRC :112-2011
OK OK OK OK OK
* DIAPHRAGM LOADS
156 178 179 201 UNI GY -1.620
202 224 248 to 251 UNI GY -1.620
LOAD 2 SLAB LOADS
MEMBER LOADS
* SLAB LOADS
156 178 179 201 uni gy -0.680
202 224 248 to 251 uni gy -0.680
133 155 225 247 UNI GY -0.408
134 TO 136 152 TO 154 UNI GY -0.141
226 TO 228 244 TO 246 UNI GY -0.141
157 TO 159 175 TO 177 UNI GY -0.141
180 TO 182 198 TO 200 UNI GY -0.141
203 TO 205 221 TO 223 UNI GY -0.141
137 151 UNI GY -0.281
229 243 UNI GY -0.281
160 174 UNI GY -0.281
183 197 UNI GY -0.281
206 220 UNI GY -0.281
138 150 UNI GY -0.605
230 242 UNI GY -0.605
161 173 UNI GY -0.605
184 196 UNI GY -0.605
207 219 UNI GY -0.605
139 TO 149 UNI GY -0.788
231 TO 241 UNI GY -0.788
162 TO 172 UNI GY -0.788
185 TO 195 UNI GY -0.788
208 TO 218 UNI GY -0.788
LOAD 3 SIDL - WEARING COAT / CRASH BARRIER / HAND RAILS / FPDL
MEMBER LOADS
* WEARING COAT LOADS
133 155 UNI GY -0.120 0.500 1.750
225 247 UNI GY -0.120 0.000 1.250
134 TO 136 UNI GY -0.041 0.500 1.750
152 TO 154 UNI GY -0.041 0.500 1.750
226 TO 228 UNI GY -0.041 0.000 1.250
244 TO 246 UNI GY -0.041 0.000 1.250
157 TO 159 UNI GY -0.041 0.000 3.000
PERFORM ANALYSIS
PRINT MEMBER FORCES
FINISH