A (A) 10vso18-140 Series 3x PDF
A (A) 10vso18-140 Series 3x PDF
A (A) 10vso18-140 Series 3x PDF
RA 92 711/05.04 1/36
Variable Axial Piston Pump Replaces: 05.95
RA 92 712/05.95
(A)A10VSO
open circuit
Contents Features
Ordering code - standard range 2 – Variable displacement axial piston pump of swashplate
Fluids 4 design for hydrostatic open circuit systems
Type of operation
Pump in open circuit O
Series
31
Direction of rotation
Viewed on shaft end clockwise R
counter clockwise L
Seals
NBR nitril-caoutchouc, shaft seal in FKM P
FKM flour-caoutchouc V
● = available
❍ = in preparation
- = not available
RA 92 711/05.04 | (A)A10VSO Industrial Hydraulics | Bosch Rexroth AG 3/36
AA10VS O / 31 -
1)
Not for new projects. Permitted with reduced through drive torque only (see page 26).
4/36 Bosch Rexroth AG | Industrial Hydraulics (A)A10VSO | RA 92 711/05.04
Fluids
We request, that before starting a project, detailed information Notes on the selection of hydraulic fluid
about the choice of hydraulic fluids and application conditions
In order to select the correct fluid, it is necessary to know the
are taken from our catalog sheets RE 90220 (petroleum oil)
operating temperature in the tank (open circuit) in relation to
and RE 90221 (environmentally acceptable hydraulic fluids).
the ambient temperature.
When using environmentally acceptable hydraulic fluids
The hydraulic fluid should be selected so that within the
possible limitations for the technical data apply. If necessary
operating temperature range, the viscosity is within the op-
please contact our technical department (please indicate type
timum range (νopt.; see shaded section of the selection dia-
of the hydraulic fluid used in your application when ordering.
gram). We recommend that the higher viscosity grade is
Operating viscosity range selected in each case.
We recommend that the operating viscosity (at operating Example: at an ambient temperature of X °F (°C) the operating
temperature) for both the efficiency and life of the unit, be temperature in the tank is 140 °F (60 °C). In the optimum vis-
chosen within the optimum range of cosity range νopt ( shaded area), this corresponds to viscosity
grades VG 46 or VG 68, VG 68 should be selected.
νopt = opt. operating viscosity 80...170 SUS (16...36 mm2/s) Important: The leakage oil temperature is influenced by
pressure and speed and is typically higher than the tank
temperature. However max. temperature at any point in the
referred to tank temperature at open circuit.
system may not exceed 195 °F (90 °C).
Viscosity limits At high temperatures please use FKM seals.
The limiting values for viscosity are as follows:
If the above mentioned conditions cannot be kept due to ex-
νmin = 60 SUS (10 mm2/s) treme operating parameters or high ambient temperatures,
short term (t ≤ 1 min) please consult us.
at a max. permissible leakage oil temperature
Filtration of fluid
of tmax = 195 °F (90 °C).
The finer the filtration, the better the achieved cleanliness of
Please note that the max. fluid temperature of 195 °F (90 °C) is
the fluid and the longer the life of the axial piston unit.
also not exceeded in certain areas (for instance bearing area).
The temperature in the bearing area is approx. 7 °F (5 K ) To ensure a reliable functioning of the axial piston unit, a mini-
higher than the average leakage fluid temperature. mum cleanliness of
νmax = 7500 SUS (1600 mm2/s) 20/18/15 acc. to ISO 44061) is necessary.
short term (t ≤ 1min)
If the above cleanliness classes cannot be met please consult
on cold start
us.
(p ≤ 435 psi/30 bar, n ≤ 1000 rpm, tmin = -13 °F/-25 °C)
1)
draft issue 1999
Selection diagram
(5000) 1000 1000 (4635)
(3000) 600
(2000) 400
Viscosity v mm2/s (SUS)
VG 68
VG
VG 32
VG 46
VG 2
(1000) 200
10
2
(500) 100
(300) 60
(200) 40 36
(150) (170)
vopt.
(100) 20
(80) 16
(80)
(70)
(60) 10
194
-13 0 20 40 60 80 100 120 140 160 180
(-20) (-10) (0) (10) (20) (30) (40) (50) (60) (70) (80) (90)
(-25)
Temperature t in °F (°C)
RA 92 711/05.04 | (A)A10VSO Industrial Hydraulics | Bosch Rexroth AG 5/36
Technical data
Inlet operating pressure range Maximum permissible speed (Speed limit)
Absolute pressure at port S Graph, showing permissible speed with increased inlet pres-
sure at port S ( pwabs ) resp. reduced displacement(Vg < Vg max ).
pabs min _____________________________________________________________ 12 psi (0,8 bar)
1,2 bar psi
pabs max __________________________________________________________ 435 psi (30 bar)
1,6 23
Speed n/nmax
Pressure at port B 1,4 20
1,1
Nominal pressure pN _________________________________ 4000 psi (280 bar)
1,2 17.5
Peak pressure pmax ____________________________________ 5100 psi (350 bar)
(Pressure data to DIN 24312)
Applications with intermittet operating pressure up to 4600 psi 1,0 1,0 14.5
(315 bar) at < 10 % duty are permissible.
0,9 13
Limitation of pump output pressure spikes is possible with relief
valve blocks mounted directly on flange connection, acc. to
data sheets RA 25 880 and RE 25 890 to be ordered 0,9 0,8 11.5
separately. 0,7 0,8 0,9 1,0
pL abs max _____________________________________________________________ 29 psi (2 bar) Important: The drive speed increase (1.2 • n0) refers to the
standard drive speed n0.
e.g. size 100: nmax = 1.2 • 2000 rpm = 2400 rpm
WRONG: 1.2 • 2400 rpm = 2880 rpm
Technical Data
Table of values
Size (A)A10VSO Standard 18 28 45 71 100 140
AA10VSO High Speed 71 100 140
Displacement Vg max in3 1.10 1.71 2.75 4.33 6.1 8.54 4.33 6.1 8.54
(cm3) (18) (28) (45) (71) (100) (140) (71) (100) (140)
Speed1), max.
at Vg max n0 max rpm 3300 3000 2600 2200 2000 1800 2550 2300 2050
at increased inlet pressure n0 max perm. rpm 3900 3600 3100 2600 2400 2100 2600 2400 2100
pabs resp. Vg < Vgmax
Flow, max
at n0 max qvo max gpm 15.7 22 31 41 53 67 48 61 76
(L/min) (59.4) (84) (117) (156) (200) (252) (181) (230) (287)
at nE = 1800 rpm qvo gpm 7.2 13.3 21.4 33.8 47.6 67 33.8 47.6 67
(L/min) (32) (59) (81) (128) (180) (252) (128) (180) (252)
Power, max. (∆p = 4000 psi (280 bar))
at n0 max Po max HP 36.6 51 72 96 124 156 112 142 177
(kW) (28) (39) (55) (73) (93) (118) (84) (107) (134)
at nE = 1800 rpm P HP 19 31 50 79 111 156 79 111 156
(kW) (15) (24) (38) (69) (84) (118) (69) (84) (118)
Torque, max.
at Vg max Tmax ft-lb 58 91 146 230 324 453 230 324 453
(∆p=4000psi (280bar)) (Nm) (80) (125) (200) (316) (445) (623) (316) (445) (623)
at Vg max T ft-lb 14.6 33 53 83 117 164 83 117 164
(∆p=1450psi (100bar)) (Nm) (28.6) (45) (72) (113) (159) (223) (113) (159) (223)
Moment of inertia J lbs-ft2 0.022 0.0403 0.0783 0.1970 0.3963 0.5743 0.1970 0.3963 0.5743
(about drive axis) (kgm2) (0.00093) (0.0017) (0.0033) (0.0083) (0.0167) (0.0242) (0.0083) (0.0167) (0.0242)
Fill volume gal. (L) 0.1 (0.4) 0.2 (0.7) 0.26 (1.0) 0.4 (1.6) 0.6 (2.2) 0.8 (3.0) 0.4 (1.6) 0.6 (2.2) 0.8 (3.0)
Weight (without fluid) ca. m lbs (kg) 26.5 (12) 33 (15) 46 (21) 73 (33) 99 (45) 132 (60) 73 (33) 99 (45) 132 (60)
Permissible loading of drive shaft
max. perm. load Fq Fax max lbf (N) 157 225 337 540 900 1080 540 900 1080
± Fax
(700) (1000) (1500) (2400) (4000) (4800) (2400) (4000) (4800)
X/2 X/2
max. perm. load2) X
Fq max lbf (N) 79 270 337 427 517 630 427 517 630
(350) (1200) (1500) (1900) (2300) (2800) (1900) (2300) (2800)
1) These values are valid for an absolute pressure of 14.5 psi (1 bar) at the suction port S. By reducing the displacement or
increasing the input pressure the speed can be increased as shown in the diagram.
2) Please consult us for higher radial forces.
Determination of size
Flow qv =
Vg • n • ηv
231
[gpm]
( qv =
Vg • n • ηv
1000
[L/min]
) Vg = Displacement per revolution in in3 (cm3)
∆ p = Differential pressure in psi (bar)
n = Speed in rpm (min–1)
Torque T =
Vg • ∆ p
24 • π • ηmh
[lb-ft]
( T=
Vg • ∆ p
20 • π • ηmh
[Nm]
) ηv = Volumetric efficiency
ηmh = Mechanical-hydraulic efficiency
ηt = Total efficiency
Power P=
qv • ∆ p
1714 • ηt
[HP]
( P=
qv • ∆ p
600 • ηt
[kW]
)
RA 92 711/05.04 | (A)A10VSO Industrial Hydraulics | Bosch Rexroth AG 7/36
Noise level
Characteristics for pump
Measured in an anechoic chamber
Distance from microphone to pump = 3.3 ft (1 m)
Measuring error: + 2 dB(A)
Fluid: Hydraulic oil to ISO VG 46 DIN 51519, t = 122 °F (50 °C)
Size 18 Size 71
74 80 qv max
qv max
72 78 qv zero
qv zero 76
70 qv max
74 n = 2200 rpm
68 n = 3000 rpm qv zero
qv max 72 n = 1800 rpm
66
qv zero 70
64 n = 1500 rpm
68
62 66
60 64
58 62
60
56
500 1000 1500 2000 2500 3000 3500 4000 psi 58
500 1000 1500 2000 2500 3000 3500 4000 psi
0 (50) (100) (150) (200) (250)(280)(bar) 0 (50) (100) (150) (200) (250)(280)(bar)
operating pressure p operating pressure p
Size 28 Size 100
74 82 qv max
qv max
72 80
qv zero qv zero
noise level LA [dB (A)]
78
70 qv max qv max
n = 2000 rpm
noise level LA [dB (A)]
qv max 80
noise level LA [dB (A)]
72 78
n = 2600 rpm n = 1800 rpm qv zero n = 1800 rpm
70 76
68 74
72
66
70
64 68
62 66
60 64
62
58
500 1000 1500 2000 2500 3000 3500 4000 psi 60
500 1000 1500 2000 2500 3000 3500 4000 psi
0 (50) (100) (150) (200) (250)(280)(bar) 0 (50) (100) (150) (200) (250)(280)(bar)
operating pressure p operating pressure p
8/36 Bosch Rexroth AG | Industrial Hydraulics (A)A10VSO | RA 92 711/05.04
Size 18
(L/min) gpm (kW) HP
n = 1500 rpm
(80) 20 (40)
n = 3300 rpm
(60) (30) 40
Flow qv
drive power P
qv Pqv max
(40) 10 (20)
20
(20) Pqv zero (10)
drive power P
n = 2000 rpm
(40) 10 (20)
20
(20) Pqv zero (10)
drive power P
n = 2000 rpm (80) (40)
20
(60) (30) 40
Pqv max
(40) 10 (20)
Pqv zero 20
(20) (10)
drive power P
Flow qv
drive power P
(160) qv (80)
40 100
(140) (70)
(120) Pqv max (60) 80
30
(100) (50)
60
(80) 20 (40)
(60) (30) 40
(40) 10 Pqv zero (20)
20
(20) (10)
drive power P
60
(220) (110)
140
(200) (100)
50
(180) (90) 120
(160) (80)
40 100
(140) Pqv max (70)
(120) (60) 80
30
(100) (50)
60
(80) 20 (40)
(60) (30) 40
(40) 10 (20)
Pqv zero 20
(20) (10)
Size 140
Size A1 A2 A3 A4 X (plugged)
18 5.83 (148) 3.52 (89.5) 3.68 (93,5) 0.12 (3) R 1/4 in
28 6.22 (158) 3.94 (100) 4.07 (103,5) 0.12 (3) R 1/4 in
45 6.81 (173) 4.33 (110) 4.47 (113,5) 0.12 (3) R 1/4 in
71 7.91 (201) 4.86 (123,5) 5.02 (127,5) 0.12 (3) R 1/4 in
100 10.55 (268) 5.06 (128,5) 5.22 (132,5) 0.12 (3) R 1/4 in
140 10.55 (268) 6.02 (153) 6.22 (158) 0.18 (4) R 1/4 in
12/36 Bosch Rexroth AG | Industrial Hydraulics (A)A10VSO | RA 92 711/05.04
DR - Pressure control
The pressure controller serves to maintain a constant pressure Circuit drawing
in a hydraulic system within the range of the pump. The pump Size 18 ... 100
therefore supplies only the amount of hydraulic fluid required
by the system. Pressure may be steplessly set at the pilot valve.
B
Static characteristic
(at n1 = 1500 rpm; toil = 122°F / 50°C)
Circuit drawing
Size 140
setting range
qv min
290 psi 4000 psi
(20 bar) operating pressure p (280 bar)
Dynamic characteristic
The opening curves are mean values measured under test
conditions with the unit mounted inside the tank.
Conditions: n = 1500 rpm
toil = 122°F (50°C)
Main relief set at 5100 psi (350 bar)
Ports
B Pressure port
Stepped loading by suddenly opening or closing the pressure
S Inlet port
line using a pressure relief valve at 3.3 ft (1 m) downstream
from the pump pressure outlet. L,L1 Case drain port (L1 plugged)
psi (bar)
5100 (350)
Controller data
4350 (300) Hysteresis and repetitive accuracy ∆p ____ max. 45 psi (3 bar)
3600 (250) Pilot oil consumption max. approx 0.8 gpm (3 L/min)
operating pressure p
0 18 50 25 20
Vgmax 28 60 30 20
45 80 40 20
71 100 50 25
100 125 90 30
(swivel angle)
displacement
Vgmin
On sizes 18 to 100 the DFR valve is used. The flow control spool is blocked and not tested.
Size 140
Size A1 A2
18 4.13 (105) 4.96 (126)
28 4.17 (106) 5.35 (136)
45 4.17 (106) 5.75 (146)
71 4.17 (106) 6.30 (160)
100 4.17 (106) 6.50 (165)
140 5.00 (127) 6.65 (169)
14/36 Bosch Rexroth AG | Industrial Hydraulics (A)A10VSO | RA 92 711/05.04
qv max
Flow qv
setting range
qv min
290 psi 4000 psi
(20 bar) operating pressure p (280 bar)
Size 140
adapter
Size A1 A2 A3 A4 A5 Port X
18 4.11 (104,5) 4.94 (125) 4.29 (109) 1.57 (40) 5.12 (130) 7/16-20 UNF-2B; 0.45 (11,5) deep
28 4.17 (106) 5.35 (136) 4.69 (119) 1.57 (40) 5.43 (138) 7/16-20 UNF-2B; 0.45 (11,5) deep
45 4.17 (106) 5.75 (146) 5.08 (129) 1.57 (40) 6.02 (153) 7/16-20 UNF-2B; 0.45 (11,5) deep
71 4.17 (106) 6.30 (160) 5.63 (143) 1.57 (40) 7.13 (181) 7/16-20 UNF-2B; 0.45 (11,5) deep
100 4.17 (106) 6.50 (165) 5.83 (148) 1.57 (40) 9.76 (248) 7/16-20 UNF-2B; 0.45 (11,5) deep
140 5.00 (127) 6.65 (169) 5.63 (143) 1.06 (27) 8.74 (222) 9/16-18 UNF-2B; 0.51 (13) deep
16/36 Bosch Rexroth AG | Industrial Hydraulics (A)A10VSO | RA 92 711/05.04
Ports
speed n B Pressure port
Dynamic characteristic operating curve S Inlet port
psi (bar) L,L1 Drain port (L1 closed)
100 5100 (350)
X Pilot pressure port
4350 (300)
4000 (280) Differential pressure ∆p:
75
3600 (250)
Standard setting: 200 psi (14 bar). If a different setting is
displacement Vg %
load pressure
Size 140
adapter
Size A1 A2 A3 A4 A5 Port X
18 4.13 (105) 4.96 (126) 4.29 (109) 1.57 (40) 4.29 (109) 7/16-20 UNF-2B; 0.45 (11,5) deep
28 4.17 (106) 5.35 (136) 4.69 (119) 1.57 (40) 5.43 (138) 7/16-20 UNF-2B; 0.45 (11,5) deep
45 4.17 (106) 5.75 (146) 5.08 (129) 1.57 (40) 6.02 (153) 7/16-20 UNF-2B; 0.45 (11,5) deep
71 4.17 (106) 6.30 (160) 5.63 (143) 1.57 (40) 7.13 (181) 7/16-20 UNF-2B; 0.45 (11,5) deep
100 4.17 (106) 6.50 (165) 5.83 (148) 1.57 (40) 9.76 (248) 7/16-20 UNF-2B; 0.45 (11,5) deep
140 5.00 (127) 8.23 (209) 7.20 (183) 1.06 (27) 8.74 (222) 9/16-18 UNF-2B; 0.51 (13) deep
18/36 Bosch Rexroth AG | Industrial Hydraulics (A)A10VSO | RA 92 711/05.04
100
Flow qv [%]
75
power valve
Size 140
power valve
Size A1 A2 A3 A4 A5 A6 Port X
28 4.17 (106) 5.35 (136) 4.69 (119) 1.57 (40) 7.60 (193) 4.21 (107) 7/16-20 UNF-2B; 0.39 (10) deep
45 4.17 (106) 5.75 (146) 5.08 (129) 1.57 (40) 8.23 (209) 4.41 (112) 7/16-20 UNF-2B; 0.39 (10) deep
71 4.17 (106) 6.30 (160) 5.63 (143) 1.57 (40) 9.37 (238) 4.88 (124) 7/16-20 UNF-2B; 0.39 (10) deep
100 4.17 (106) 6.50 (165) 5.83 (148) 1.57 (40) 11.93 (303) 5.08 (129) 7/16-20 UNF-2B; 0.39 (10) deep
140 5.00 (127) 8.23 (209) 7.20 (183) 2.22 (56,4) 12.36 (314) 5.51 (140) 9/16-18 UNF-2B; 0.51 (13) deep
20/36 Bosch Rexroth AG | Industrial Hydraulics (A)A10VSO | RA 92 711/05.04
1.87 (47.6)
3.27 (83)
0.79 (20)
0.25 (6.3) V
B
1)
Flange SAE J744 L
(1
43
82-2 (A)
DIA 3.2479(Ø82.55)h8
2.48 (63)
0.
7)
0.87 (22.2)
(6
64
3.2500
2.
2.48 (63)
2.60 (66)
2.52 (64)
View V
2.06 (52.4)
0.98 (25)
0.45 (11.5) L1
4.19 (106.4)
1.69 (43)
5.98 (152) S
5.71 (145)
7.68 (195) mech.
displacement
W limiter 1.03 (26.2)
Shaft ends
K Parallel with key R Splined shaft 3/4 in 11T S Splined shaft 3/4 in 11T U Splined shaft 5/8 in 9T
ISO 3019-1 19-1 16/32 DP1) 16/32 DP1) 16/32 DP1)
SAE J744-19-4 (A-B) SAE J744-19-4 (A-B) SAE J744-16-4 (A)
0.1884
0.1874
(4.76+0.025 )
1/4-20UNC-2B
0.83 (21.1)
Centering3)
R3.15x6.7 DIN332
3/4 in
Ø 3/4 in
DIA 0.7500 (Ø19.05–0.02)
Centering3)
R3.15x6.7 DIN332
1.13 (28.6) 0.55
0.87 (22)
0.10 (2.5) (14)
1.18 (30)
0.7492
0.62 (15.8)
1.50 (38) 1.50 (38) 0.94 (23.8)
1.25 (31.8)
1.30 (33) usable spline length
1.61 (41)
View V
mech.
displacement
limiter
Shaft ends
K Parallel with key R Splined shaft 7/8 in 13T 16/32 DP1) S Splined shaft 7/8 in 13T 16/32 DP1)
ISO 3019-1 22-1 SAE J744-22-4 (B) SAE J744-22-4 (B)
View V
mech. displacement
limiter
Shaft ends
K Parallel with key R Splined shaft 1 in 15T 16/32 DP1) S Splined shaft 1 in 15T 16/32 DP1) U Splined shaft 7/8 in
ISO 3019-1 25-1 SAE J744-25-4 (B-B) SAE J744-25-4 (B-B) 13T 16/32 DP1)
SAE J744-22-4 (B)
in
9,
View V
mech. displacement
limiter
Shaft ends
K Parallel with key R Splined shaft 1 1/4 in 14T 12/24 DP1) S Splined shaft 1 1/4 in 14T 12/24 DP1)
ISO 3019-1 32-1 SAE J744-32-4 (C) SAE J744-32-4 (C)
in
mech.
displacement
limiter min.
mech.
Flange SAE J744 displacement
View V
127-2 (C) limiter min.
mech. displacement
limiter
mech.
displacement
limiter max.
Shaft ends
K Parallel with key S Splined shaft 1 1/2 in 17T 12/24 DP1) U Splined shaft 1 1/4 in 14T 12/24 DP1)
ISO 3019-1 38-1 SAE J744-38-4 (C-C) SAE J744-32-4 (C)
in
mech.
View V
displacement
limiter min.
mech. displacement
limiter
mech.
displacement
limiter max.
Shaft ends
K Parallel with key S Splined shaft 1 3/4 in 13T 8/16 DP1)
ISO 3019-1 44-1 SAE J744-44-4 (D)
Through drives
Axial piston units (A)A10VSO can be supplied with a through drive as shown in the ordering code on page 3. The type of through
drive is determined by codes (K40-K...). If the combination pump is not mounted in the factory, the simple type code is sufficient.
Included in this case are: shaft coupler, seals, and if necessary an adapter flange.
Maximum permissible input and through drive torque.
Ttot Tthr
The drive torques for pump 1 and pump 2 can be split up as required. However the max. permissible input torque Ttot as well as
the max. permissible through drive torque Tthr may not be exceeded.
omitted on
size 28
thread
metric
to pump mounting flange
5.75
DIA 146)
(Ø
omitted on
thread
M12
5.75
DIA 146)
(Ø
omitted on
thread
M12
size 28
0.39 (10) metric
B A3
to pump mounting flange A1
1)
Not for new projects. Permitted with reduced through drive
torque only (see page 26).
30/36 Bosch Rexroth AG | Industrial Hydraulics (A)A10VSO | RA 92 711/05.04
omitted on
size 28 thread
metric
to pump mounting flange
thread
metric
to pump mounting flange
thread
metric
to pump mounting flange
1)
Not for new projects. Permitted with reduced through drive
torque only (see page 26).
RA 92 711/05.04 | (A)A10VSO Industrial Hydraulics | Bosch Rexroth AG 31/36
thread
to pump mounting flange metric
9
4.1
+0.050
DIA 06.5)
3.2520
DIA3.2508
(ø
(ø1
3.2520
DIA 3.2508
(ø101,6+0,020)
+0,050
1 100 13.31 1.87 0.72 2.56 M12; 0.79 (20) deep
4.0020
DIA4.0008
(ø
A5
(350) (47,5) (18,4) (77)
0.39 (10)
B A2
to pump mounting flange A1
thread
metric
7.13
+0.050
DIA 1) 140 13.78 2.36 0.77 3.03 M16; 0.95 (24) deep
5.0020
DIA 5.0008
(ø18
(350) (60) (19,4) (77)
B 0.51 (13)
A2
to pump mounting flange A1
thread
to pump mounting flange metric
1)
pressure angle 30°, flat root side fit, tolerance class 5
RA 92 711/05.04 | (A)A10VSO Industrial Hydraulics | Bosch Rexroth AG 33/36
thread
to pump mounting flange metric
34/36 Bosch Rexroth AG | Industrial Hydraulics (A)A10VSO | RA 92 711/05.04
ht min
L S
L1 L1
min. 8 in (200mm) fig. 3
S
fig. 1 Arrangement outside the reservoir
Arrangement outside the reservoir Fill pump housing before commissioning.
Before installation fill pump housing while keeping it in a Pipe port “S“ and the higher port “L“ or “L1“
horizontal position. For mounting above the tank see fig. 2. a) When mounting above the reservoir: see fig. 4 (compare
item limiting conditions)
Limiting condition:
b) Mounting below the reservoir: pipe ports “L“ and “S“
Min. pump inlet pressure pabs min = 12 psi (0,8 bar) under static
according to fig. 5, “L“ closed.
and dynamic loading.
Note: Avoid mounting above tank wherever possible in order to
attain a low noise level. L
S
The permissible suction height h is a result of the overall
pressure loss, but may not be greater than hmax = 31.5 in (800
mm) (Immersion depth ht min = 8 in/200 mm). Fluid
ht min hmax
L1
L1 L
baffle
S fig. 4
ht min hmax
Fluid
Fluid
baffle fig. 2
ht min
Safety information
– Pump (A)A10VSO was designed for operation in open loop circuits.
– Systems design, installation and commissioning require trained technicians or tradesmen.
– All hydraulic ports can only be used for the fastening of hydraulic service lines.
– Tightening torques:
The tightening torques mentioned in this data sheet are maximum values and must not be exceeded (max. values for thread).
Manufacturers information concerning the maximum permitted tightening torques of the various fittings is to be observed!
For ISO68/DIN 13 mounting bolts, we recommend that tightening torques be checked on a case by case basis in accordance
with VDI 2230, published 2003.
– During and shortly after operation of a pump the housing and especially a solenoid can be extremely hot, avoid being burned!
36/36 Bosch Rexroth AG | Industrial Hydraulics (A)A10VSO | RA 92 711/05.04