Lecture 36 - Lacing Systems

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

Course on Design of Steel Structures

Professor Damodar Maity


Department of Civil Engineering
Indian Institute of Technology Kharagpur
Lecture 36
Module 8
Lacing Systems

In this lecture we are going to discuss about the lacing systems. Lacing systems are used
basically to keep the built up sections throughout its length and we need to tie them to make
them parallel and to make them equidistant and to make them act as a monolithically, so that
as a whole the built up section works.

So for that we may use lacing which are basically some inclined member between the two
vertical members. We can also use batten system instead of lacing system. Batten system is
basically it is a horizontal plate which are connected with the two main members. But in this
lecture we will be discussing about the lacing member which are basically the inclined
members and these lacing members are used when compressive loads are acts eccentrically.
Therefore especially for eccentric loading we generally prefer lacing system.

Now for lacing system the lacing members are generally flat plate, it may be angle section, it
may be light channel section, or may be circular section means tubular section, so in different
way we can provide.
(Refer Slide Time: 1:53)

Now in case of lacing member again we can consider two type of lacing member as shown in
the figure.

So we can provide as a single lacing or we can provide double lacing also. So in different
way we can connect the lacing members. So when we will be designing we have to first
decide whether we are going for single lacing or double lacing because accordingly the force
on lacing member will come into picture that has to be taken care.

(Refer Slide Time: 3:21)

Now when we will be going for designing of a lacing we need to know what the failure
modes of the lattice member are. So what type of failure may happen that we will first see
and accordingly we will try to develop a design methodology so that the failure can be
pretend. Built-up members may fail due to buckling of built up member as a whole. So in
case of buckling of built up member as a whole, if column is very slender and axial load is
much high then it may buckle as shown in the figure.

Another way it may fail that buckling of main component as shown in the figure. So what we
could see if the loading whatever it is coming for that if the member is not able to carry that
much load due to excessive buckling then the main component may fail. if we use channel
section as a main component then the minimum radius of gyration will be about y-y, so the
failure will happen about that section. So as a local failure this can arise buckling of main
component.

(Refer Slide Time: 5:48)

Then another way of failure is the distortion of the section. Say for example there is a built up
section as shown in the figure where lacing has been provided. Now if distortion happens it
will be something like this, so due to distortion the failure may happen which has to be taken
care.

Another failure is the failure of lacing member or batten member whatever we are providing
that has to be also taken care. Say for example if we provide two built up sections with the
lacing and its width is less compared to its length then it may buckle.

Now what we need to do is that we will design the lacing system in such a way that it will
arrest the failure of local buckling, it will arrest the failure of lacing system and it will take
care the failure of member as a whole means globally and also distortion.
(Refer Slide Time: 7:46)

Now L/rcmin, the slenderness ratio of the highlighted member as shown in the figure should be
limited otherwise it may fail. Therefore we should provide some restriction and to restrict the
slenderness ratio we have to restrict the length that means spacing between two lacing has to
be decided. So from failure of local buckling we can find out what should be the maximum
distance between two lacing L.

(Refer Slide Time: 8:34)

Again if the lacing cross section is not sufficient to take the load, lacing member may fail.
Therefore what should be the width of the lacing member, what should be the thickness of the
lacing member that has to be decided from which the slenderness ratio is calculated.
Now if we are providing two sections which will be connected by lacing or batten then to
prevent the global failure we need to take the section spacing in such a way that the
slenderness ratio of the built up section should not exceed the limiting value.

(Refer Slide Time: 9:55)

So now coming to the general requirements which has been given in the code. Clause 7.6 of
IS: 800-2007 says that the compression member comprising of two main components laced
and tied should where practicable, have a radius of gyration about the axis perpendicular to
the plane of lacing not less than the radius of gyration about the axis in the plane of lacing. So
this has to be taken care. Therefore as far as practicable lacing system shall not be varied
throughout the length of the strut that means the lacing spacing and lacing dimension should
not be varied along its length.

(Refer Slide Time: 10:45)


Now coming to the single lacing system say for example we have a channel section toe to toe
and we have face A and face B then we can provide the lacings as in the prefer orientation as
shown in the figure. Whereas we cannot provide the lacing as not preferred orientation.

(Refer Slide Time: 11:41)

So this is also mentioned in the code, we can see here that the preferred lacing arrangement
where lacing on face A and lacing on face B has been made. So one is shadow of the others
and this is given in the IS: 800-2007 figure 10A and in figure 10B. In the figure 10A,
preferred arrangement for single lacing system is given. Whereas in figure 10B, preferred
arrangement for double lacing system is given.

(Refer Slide Time: 12:41)


Again in the figure 10C of that code, it is given that double lacing system and single lacing
system on opposite sides of the main components shall not be combined with cross members
perpendicular to the longitudinal axis of the strut unless all forces resulting from deformation
of the strut members are calculated and provided for in the lacing and fastenings.

(Refer Slide Time: 13:40)


Now in design specification first it is told that the total transverse shear force V will be the
2.5 percent of the compressive force P, because in lacing when we are going to design a
lacing, lacing will be undergoing some compression or tension. Now the transverse shear
force is calculated from the axial compressive force.

(Refer Slide Time: 14:52)

Now if we can consider θ as the angle of inclination for a single lacing system of two parallel
faces then the force on each bar will be

V V
F= =
nsinθ 2 sinθ
Where n is the number of transverse system in parallel plane which is generally 2. Now for
double lacing the force will be

V
F=
4 sinθ

This force will be tensile in one lacing bar and compressive in other bar.

(Refer Slide Time: 16:57)

Now as I told the lacing member may buckle locally, so the code has provided certain
restriction which is given in tabular form here that what should be the effective length and
what should be the slenderness ratio. The slenderness ratio (le/r) of the lacing bar should not
exceed by 145 that means as per the codal provision we have to make the dimension of a
lacing system in such a way that the slenderness ratio should not become more than 145.

And to calculate the effective length it has been also discussed in the code that in case of
single lacing with bolted end, effective length, le will be the overall length,,l where l is the
length between inner end bolts of lacing bar. And for double lacing bolted at ends and
intersections, le will be 0.7l and for welding lacing also it will be 0.7l

(Refer Slide Time: 18:54)

Now if we use flat bars as lacings then the slenderness ratio is calculated as follows:

le l e √ 12
l l ¿ =
λ= e = e t
r √I / A
√ b t 3 /12
bt
l e √ 12
∴ λ lacing= <145
t
(Refer Slide Time: 19:55)
Now in riveted/bolted connection, the minimum width of lacing bars should be more than
three times the nominal diameter of the end connector. So if the width of lacing bar is b and
the nominal diameter of the end connector is d then b should be greater than or equal to 3d.

(Refer Slide Time: 20:41)

Then coming to thickness, thickness either we can find out from that the slenderness ratio
value or at the beginning we can find out the thickness from the following criteria

l
t> for single lacing
40
l
t> for double lacing
60
Where, l is the length between the inner end bolts or welds

So the minimum thickness of the lacing bar can be found from these criteria for single lacing
and as well as for double lacing.

(Refer Slide Time: 21:45)


Then another important thing we have to decide that is the angle of inclination (θ) of the
lacing bar. Lacing bars, whether in double or single systems, shall be inclined at an angle not
less than 400 nor more than 700 to the axis of the member. However from the experience it
has been seen that the lacing system will be effective if we consider θ in between 35 and 45.

(Refer Slide Time: 22:30)

Then the maximum spacing of lacing bars should be such that minimum slenderness ratio
will be,

L
=0.7 λ max or
r cmin

¿ 50
Whichever is minimum.

Where, λmax is the maximum slenderness ratio of the compression member as a whole

L = Distance between centers of connections of the lattice bars to each component

c
r min = Minimum radius of gyration of the component of compression members
(Refer Slide Time: 24:00)

Now we need to find out certain number of bolts or welding dimensions for attachment of
lacing to the main component and that is dependent on the force acting on lacing member or
if we use weld connection the length of weld connection, size of weld connection should be
decided.

So the codal provision says that the riveting, bolting or welding of the lacing bars to the main
member should be sufficient to transmit the load in the bar. Then in case of weld connection
it is told that where welded lacing bars overlap the main members, the amount of lap
measured along either edge of the lacing bar shall be not less than the four times the thickness
of the bar or the members whichever is less.

And the welding should be sufficient to transmit the load in the bar and shall in any case we
provided along each side of the bar for the full length of lap, so this is what we have to
remember in case of weld connection. And for bolt connection we have to find out the
strength and number of bolts.
(Refer Slide Time: 25:29)

So in case of such member means such type of connection where connections are made
separately then the number of bolts can be decided as

F
For first case, the numbers of bolt, n=
R

But for second case where both the members are acting on this bolt, we have to find out the
resultant force which will be 2Fcosθ and for this particular case

Resultant Force 2 Fcosθ


The numbers of bolt, n= =
Bolt Value R

Where, F = Force in lacing bar

θ = Inclination

So if we find out the force in lacing bar then we can find out the number of bolt required to
connect the lacing bar with the main plate and this depends on what type of connections we
are going to consider whether it is separately connecting or two lacings are overlapped and
acting as a double shear. So here also you can see that the bolt value of this case and bolt
value of this case will be different, because here the bolt value will be under single shear and
here the bolt value will be under double shear, so accordingly the bolt value has to be
calculated.

So these are the things we have to remember when we will be going to design a lacing
member so in short if we say that lacing members are designed or the entire built up sections
are designed on the basis of failure criteria, failure of the member as a whole. So we have to
restrict the radius of gyration so that failure does not occur and to restrict the failure due to
local buckling of the main member we have to provide the spacing for lacing in such a way
that the slenderness ratio should not exceed certain value.

Also we have to find out a suitable arrangement of bolt or weld connection for attaching the
lacing system into the main members if we use bolt connection then again we have to see
whether we are connecting the lacing member separately or we are overlapping accordingly
the forces will be calculated and then the number of bolts will be calculated and in fact if we
see the force on the lacing member is quite less and generally number of bolts become 1 to 2
in maximum case and sometimes we will see 2 that is sufficient. So through work out
example we will also confirm this.