EHYD3 Hydraulic Cartridge HY15-3501 CEsec1

Download as pdf or txt
Download as pdf or txt
You are on page 1of 27

Catalog HY15-3501/US

Contents Coils and Electronics


CV
SERIES DESCRIPTION PAGE NO.

Valves
Check
SUPER COILS
CC ............................................... 1/2″ Solenoid Tubes ................................................................................... CE3-CE4 SH
CA ............................................... 5/8″ Solenoid Tubes ................................................................................... CE5-CE6

Shuttle
Valves
STANDARD COILS
Unicoil ........................................ 1/2″ Solenoid Tubes ................................................................................... CE7-CE8
Unicoil ........................................ 5/8″ Solenoid Tubes ................................................................................. CE9-CE10 LM

Load/Motor
Controls
DS .............................................. 1/2″ Solenoid Tubes ............................................................................... CE11-CE12
DS .............................................. 5/8″ Solenoid Tubes ............................................................................... CE13-CE14
DS .............................................. 1″ Solenoid Tubes ............................................................................................ CE15 FC

Controls
Flow
ELECTRONICS
V XPRO902 .................................... 12 VDC PWM Controller, 110Hz, 19W ................................................... CE17-CE18
I PC
XPRO932 .................................... 12 VDC PWM Controller, 110Hz, 30W ................................................... CE17-CE18

Pressure
Controls
XPRO904 .................................... 24 VDC PWM Controller, 110Hz, 19W ................................................... CE17-CE18
XPRO934 .................................... 24 VDC PWM Controller, 110Hz, 30W ................................................... CE17-CE18
LE
XPRO902d .................................. 12 VDC PWM Controller, 95-230Hz, 19W .............................................. CE19-CE20

Elements
V XPRO932d .................................. 12 VDC PWM Controller, 95-230Hz, 30W .............................................. CE19-CE20

Logic
I
XPRO904d .................................. 24 VDC PWM Controller, 95-230Hz, 19W .............................................. CE19-CE20 DC
XPRO934d .................................. 24 VDC PWM Controller, 95-230Hz, 30W .............................................. CE19-CE20

Directional
Controls
XPRO902rid ............................... 12 VDC PWM Controller, 95-230Hz, 19W, Multi-adj. ............................. CE21-CE22
XPRO932rid ............................... 12 VDC PWM Controller, 95-230Hz, 30W, Multi-adj. ............................. CE21-CE22
MV
XPRO904rid ............................... 24 VDC PWM Controller, 95-230Hz, 19W, Multi-adj. ............................. CE21-CE22

Manual
Valves
XPRO934rid ............................... 24 VDC PWM Controller, 95-230Hz, 30W, Multi-adj. ............................. CE21-CE22

XPRO704 .................................... Soft Start Valve Controller, 12/24 VDC ............................................................. CE23 SV

Solenoid
Valves
PV
XPRO704b .................................. Soft Start and Stop Valve Controller, 12/24 VDC .............................................. CE24

Proportional
Valves
CE
Electronics
XPRO804 .................................... Power Saver Controller, 12/24 VDC PWM ........................................................ CE25
Coils &

BC
Bodies &
Cavities

TD
Technical
Data

Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3501/US
Technical Tips Coils and Electronics
CV
INTRODUCTION
This technical tips section is designed to help familiarize you with the Parker line of Coils. In this section we
Valves
Check

highlight the features and discuss some of the available options. We also use this section to present some
common terminology related to coil and coil technology.
SH
Shuttle
Valves

New Parker SUPER COIL


LM
Now Available!
Load/Motor
Controls

Class N Magnetic Wire


Internal wires have a class N
DC Windings
rating, providing longer
All coils are DC wound. An internal
FC life at typical
full wave rectifier is added for AC
temperatures.
current, eliminating inrush current,
Controls

and allowing for voltage interchangeability.


Flow

PC Variety of Terminations
Coils are offered in a wide variety
Pressure

of terminations, including integrally


Controls

molded connectors and voltages to


meet your system requirements.

LE Rugged Thermoplastic Encapsulation


Coil is encased in a thermoplastic polyester
Elements

resin. This allows for higher temperature


Logic

exposure and less flexural creep. Also, this


resin is resistant to moisture,
caustic solutions, and
Low Carbon
DC fungus providing
Steel Frame
protection for
Zinc plated low
Directional

coil windings.
carbon steel frame
Controls

surrounds coil, increasing


flux density. Low carbon steel provides better
magnetic properties and greater permeability.
MV
Diodes
Internally molded
Manual
Valves

diodes are available.


Polarity is molded into coil
for ease of installation.
SV
Ribbed Surface
External ridges
Solenoid

provide a larger
Valves

coil surface area, which


allows for better heat dissipation.

PV
Proportional

*Exceeds IP69k Specifications


Valves

After exhaustive testing, the new Super Coil has clearly distanced itself from the competition. This coil was
subjected to the rigors of this environmental standard and the results were excellent. This coil stands up to
CE most rugged of environmental conditions including weather, dust, and extreme temperature variations.
Electronics

*Water Dunk Test Qualified


Coils &

The Super Coil was taken to task in a repeated water dunk thermal cycle test program with alternate
exposure to high and low temperature, only to perform with outstanding results.
BC *Endurance Tested
The goal of this test was to cycle the coil to high temperature extremes in order to validate the coils ability to
Bodies &

perform in extreme temperature environments.


Cavities

*Water Spray and Chemical Solvent Compatibility


The Super Coil was subjected to numerous chemical solvents in a rigorous test which established the fact
TD that these coils can withstand harsh and unusual environments. Also, the coils were subjected to a high
pressure water spray test. Once again, the Super Coil passed this test.
Technical

*Deutsch connector required.


Data

CE1 Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3501/US
Technical Tips Coils and Electronics
CV
COMMON OPTIONS
Below are some of the common options to the Unicoil product offering.

Valves
Check
Continuous Duty: Parker’s standard line of coils are Voltages: Parker has a wide selection of coils avail-
rated for continuous duty operation. This means the able to meet your needs. Most coil terminations are SH
coil can be left on continuously without fear of the available with our standard voltages of 12V and 24V in
magnet wire insulation breakdown, when used in DC, and 120V and 240V in AC. Voltages 6V, 10V, 18V,

Shuttle
Valves
standard climate conditions. The Unicoils and Super 36V, 48V DC and 440V AC are also available for many
Coils are made of a high quality Class N magnet wire. termination types at a slight premium. Contact your
This Class N rating signifies the internal wires are Parker representative should your application call for LM
rated to 200°C (392°F). voltages other than our standard offering.

Load/Motor
Controls
Continuous duty does not mean the coil will have the Diodes: The Parker Coils can be ordered with a diode
same amount of power after hours of operation as it molded internally. Parker Unicoils use a IN5062 diode.
had at initial actuation. Coils do heat up during use. The Super Coils use a IN5627 diode. Diodes are FC
This internal heat rise increases the resistance of the sometimes used to protect sensitive, downstream

Controls
coil and thus, decreases the current (V = IR). The electrical components from potential surges from the

Flow
performance curves presented on the solenoid valve coil. By internally molding the diode into the coil, you
pages are based on a coil at room temperature and can reduce the assembly time
85% of voltage. Thus, when using a valve in continu- and cost associated with PC
ous duty applications, you may need to derate the externally wiring a diode.

Pressure
Controls
performance. In short, the continuous duty rating One should be careful
signifies that while the coil will get hot during use and not to switch the polarity
resistance will increase, it will not generate enough (“+” and “-” terminals), when wiring a coil with an
heat to damage the coil. internal diode. If these terminals are switched, the first LE
time voltage is applied to the coil; the short circuit will

Elements
Terminations: Parker offers a wide variety of coil destroy the diode and render the coil use-less. Parker

Logic
terminations for all coils to meet the demands of your coils with diodes have “+” and “-” molded near the
application. Over the years, the dual lead wire and dual termination outlet to help identify polarity. DC
spade offerings have been popular due to their ease of

Directional
installation and availability. In the past few years, the DIN Connectors: Parker does offer connectors for use

Controls
demand for more secure termination connections has with the DIN style coils. As shown below, the DIN
increased. In addition, the integral connectors reduce connectors are available in both rectified and non-
cost and improve integrity by reducing the number of rectified forms. The cable gland versions can be MV
connections. As such, the Amp Junior, Weatherpack, ordered for type PG9 or PG11.
Metri-Pack, and Deutsch have increased in popularity.

Manual
Valves
Cable Gland 1.57 .39
We offer these connectors on a lead wire coil, as well
as an internally molded version of the DIN, Amp Type Non-Rectified Rectified
Junior, and Metri-Pack coils. If you do not find your PG9 710549-00 712126-01 1.04 SV
PG11 710549-01 712126-00
desired coil termination in our catalog, contact your

Solenoid
factory sales representative. We entertain special

Valves
.06
requests and have several special terminations not
1.04
listed in this catalog.
PV

Proportional
Current Types: Both direct current (DC) and alternat- 1.04
ing current (AC) versions are available for the Parker

Valves
line of coils. The AC versions are essentially DC coils
with a full wave rectifier integrally molded into the coil. Conduit Rectified Conduit Non-Rectified
The rectifiers are rated for voltage peaks up to 1000 CE
712704-00 710549-02
Electronics

volts maximum. For voltage transients greater than


Coils &

1000 volts, a Harris Thyrector is recommended. The 2.45 1.57


AC coils operate at 50/60 cycles (Hz). Since the AC
versions are rectified 1.04
AC Coil Assembly
1.37 BC
DC coils, there is .06
no inrush current
Bodies &
Cavities

like with “true” .06 .22


AC coils. It 1.06 .22 1.04
also means TD
DC coils and
Technical

1.06 Ø 1.00 1.04


AC coils are Voltage Surge
interchangeable.
Data

Suppressor (Thyrector)

CE2 Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3501/US Super Coil
Technical Information Series 1/2″″ I.D.
CV
Features
• Integral Deutsch connector coil exceeds IP69K
Valves
Check

standards

SH • Integral Deutsch connector coil thermal shock dunk test


rated
• Integral Amp Jr. coil exceeds IP67 standards for thermal
Shuttle
Valves

shock, water resistance and “dunk capability”


• Universal 50/60 Hz operation
LM • Waterproof coil hermetically sealed, requires
Load/Motor

no O-rings or waterproofing kits


Controls

• External plated steel flux-carrying band (unlike


encapsulated band) enables coil to withstand severe Ordering Information
thermal shocks without cracking
FC
• Symmetrical coil can be reversed without
affecting performance CC
Controls
Flow

Specifications Super Coil Wattage Voltage Termination


1/2″″ I.D.
PC Coil Type S Standard
P Puissant Code Wattage
Pressure
Controls

Nominal Wattage S 14 Watts S Standard


(See Ordering P 19 Watts P Puissant
LE Information For
Exact Wattage) Code Voltage
Watts Amps Ohms**
Elements

Duty Cycle Continuous @ 100% voltage Volts S P S P S P


Logic

Magnetic Wire ‘N’ Rated at 200°C (392°F) 010 10 VDC 14 19 1.38 1.90 7.25 5.26
DC Insulation Class 012* 12 VDC 14 19 1.15 1.58 10.43 7.58
018 18 VDC 14 19 0.77 1.06 23.48 17.05
Directional

Temperature -40°C to +200°C


Controls

Range (-40°F to +392°F) 024* 24 VDC 14 19 0.58 0.79 41.74 30.30


Temperature S 75°C (135°F) 048 48 VDC 14 19 0.29 0.40 167.0 121.3
Rise At Nominal P 95°C (172°F) 115* 115 VAC 16 19 0.17 0.20 680 576
MV
Voltage And 230 230 VAC 17 22 0.09 0.12 2596 1919
Natural Ventilation *Standard **Resistance ±10% at 68°F
Manual
Valves

Dielectric Strength .0005 In dry lab condition at Code Termination


Maximum Current 1000V AC for 30 seconds A Amp Jr. (DC Only)
SV Leakage (Amps) .001 After being immersed in 23°C
AD Amp Jr. with 3 Amp Diode (DC Only)
(77°F) water with waterproof
C Double Lead Wire with Conduit Connector (AC Only)
Solenoid

connector for 24 hours at


Valves

500V AC D DIN 43650 (AC or DC, Supplied without DIN Connector)


H Integral Deutsch
Encapsulating Glass filled rynite
PV Material HE Integral Deutsch with 3 Amp Diode
Proportional

L Double Lead (DC Only)


Color Identification S Black Ring
LD Double Lead with Deutsch Connector
Valves

On The Terminal P Red Ring DT04-2P-EP04 (DC Only) (Use ‘H’ series if possible)
Boss
LE Double Lead with 3 Amp Diode (DC Only)
CE Weight 0.20 kg (0.44 lbs.) PF Double Lead Wire with Packard Female Weather Pack
Electronics

Connector 1201 5792 (DC Only)


AC Coil Assembly
Coils &

PM Double Lead Wire with Packard Male Weather Pack


Connector 1201 0973 (DC Only)
S Double Spade (DC Only)
BC W Double Screw (DC only)
WE Double Screw with 3 Amp Diode (DC Only)
Bodies &
Cavities

Y Single Screw (Internally Grounded, DC Only)


Note: Additional voltages and other terminals are available. Some coils are UL
approved. For details please consult factory.
TD DIN Female Mating Connector: See page CL2
Deutsch Mating Connector: # DT06-25
Technical

Packard Male Weather Pack Connector: 12010973


Packard Female Weather Pack Connector: 12015792
Data

CE3 Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3501/US Super Coil
Technical Information Series 1/2″″ I.D.
CV
Terminal Styles and Dimensions

Valves
Check
19.8
(0.78) L - Double Lead A - Amp Junior
S - Double Spade 18 gauge 457mm 18" long AD - Amp Junior
black color
with 3 Amp Diode
(+ and - metered) SH
33.8

Shuttle
Valves
(1.33)

MADEINU.S.A.
PAT.XXXXXXX

MADEINU.S.A.
PAT.XXXXXXX

MADEINU.S.A.
PAT.XXXXXXX
CCX XXX H

CCX XXX H

CCX XXX H
XXVDC XXW

XXVDC XXW

XXVDC XXW
LM

Load/Motor
13 Ø (.52) I.D.

Controls
56.0 53.0 67.0
(2.21) (2.07) (2.62)
39.6
(1.56) Y - Single Screw LE - Double Lead
(Internal ground) with 3 Amp Diode FC
8-32 UNC screw & nut 18 gauge 457mm (18") long
W - Double Screw Red wire positive,

Controls
8-32 UNC screw & nut Black wire negative PF - Female PM - Male
MADEINU.S.A.
PAT.XXXXXXX
CCX XXX H

Diode protection from


XXVDC XXW

WE - Double Screw

Flow
positive to negative
Packard Packard
39.6 with 3 Amp Diode Connector Connector
(1.56) (+ and - metered)
PC

Pressure
Controls
MADEINU.S.A.
PAT.XXXXXXX

MADEINU.S.A.
PAT.XXXXXXX
CCX XXX H

CCX XXX H
XXVDC XXW

XXVDC XXW
Part No. Voltage
LE

Elements
57.0 53.0
(2.25) (2.07)

Logic
177.0
H - Integral Deutsch (7.0)
C - Double Lead DT04 - 2P - EP04 DC
Conduit (1/2" NPTF) HE - Integral Deutsch D - DIN 43650

Directional
18 gauge 457mm 18" long, black color (ground wire on AC only)
with 3 Amp Diode

Controls
MADEINU.S.A.
PAT.XXXXXXX
CCX XXX H
XXVDC XXW
(+ and - metered)
MADEINU.S.A.
PAT.XXXXXXX
MADEINU.S.A.
PAT.XXXXXXX

CCX XXX H
MADEINU.S.A.
PAT.5002253
CCX XXX H

CCX XXX H

XXVDC XXW
XXVDC XXW

XXVDC XXW

MV
53.0
(2.07)

Manual
Valves
75.0 62.74 64.0
(2.97) (2.47) (2.53)
SV
NOTES:

Solenoid
Valves
1. The standard A.C. coil includes a molded-in full wave rectifier rated for 800 peak reverse voltage.
2. All P Puissant (high wattage) coils use a red ring as an indiction marker on the terminal boss.

PV

Proportional
Valves
CE
Electronics
Coils &

BC
Bodies &
Cavities

TD
Technical
Data

CE4 Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3501/US Super Coil
Technical Information Series 5/8″″ I.D.
CV
Features
• Integral Deutsch connector coil exceeds IP69K
Valves
Check

standards

SH • Integral Deutsch connector coil thermal shock dunk test


rated
• Integral Amp Jr. coil exceeds IP67 standards for thermal
Shuttle
Valves

shock, water resistance and “dunk capability”


• Universal 50/60 Hz operation
LM • Coil hermetically sealed, requires no O-rings or
Load/Motor

waterproofing kits
Controls

• External plated steel flux-carrying band (unlike


encapsulated band) enables coil to withstand severe Ordering Information
thermal shocks without cracking
FC
• Symmetrical coil can be reversed without
affecting performance CA
Controls
Flow

Specifications Super Coil Wattage Voltage Termination


5/8″″ I.D.
PC Coil Type S Standard
P Puissant Code Wattage
Pressure
Controls

Nominal Wattage S 18 Watts S Standard


(See Ordering P 28 Watts P Puissant
LE Information For
Exact Wattage) Code Voltage
Watts Amps Ohms**
Elements

Duty Cycle Continuous @ 100% voltage Volts S P S P S P


Logic

Magnetic Wire ‘N’ Rated at 200°C (392°F) 010 10 VDC 18 28 1.80 2.80 5.56 3.57
DC Insulation Class 012* 12 VDC 18 28 1.50 2.33 8.00 5.14
018 18 VDC 18 28 1.00 1.56 18.0 11.6
Directional

Temperature -40°C to +200°C


Controls

Range (-40°F to +392°F) 024* 24 VDC 18 28 0.75 1.17 32.0 20.6


Temperature S 75°C (135°F) 048 48 VDC 18 28 0.38 0.58 128.0 82.3
Rise At Nominal P 95°C (172°F) 115* 115 VAC 18 28 0.20 0.26 554 417
MV
Voltage And 230 230 VAC 18 28 0.10 0.15 2100 1430
Natural Ventilation *Standard **Resistance ±10% at 68°F
Manual
Valves

Dielectric Strength .0005 In dry lab condition at Code Termination


Maximum Current 1000V AC for 30 seconds A Amp Jr. (DC Only)
SV Leakage (Amps) .001 After being immersed in 23°C AD Amp Jr. with 3 Amp Diode (DC Only)
(77°F) water with waterproof
C Double Lead Wire with Conduit Connector (AC Only)
Solenoid

connector for 24 hours at


Valves

500V AC D DIN 43650 (AC or DC, Supplied without DIN Connector)


H Integral Deutsch
Encapsulating Glass filled rynite HE Integral Deutsch with 3 Amp Diode
PV Material HS Integral Deutsch with Internal Seal
Proportional

Color Identification S Black Ring L Double Lead (DC Only)


Valves

On The Terminal P Red Ring LD Double Lead with Deutsch Connector


Boss DT04-2P-EP04 (DC Only) (Use ‘H’ series if possible)
LE Double Lead with 3 Amp Diode (DC Only)
CE Weight 0.29 kg (0.64 lbs.) PF Double Lead Wire with Packard Female Weather Pack
Electronics

Connector 1201 5792 (DC Only)


AC Coil Assembly
Coils &

PM Double Lead Wire with Packard Male Weather Pack


Connector 1201 0973 (DC Only)
S Double Spade (DC Only)
BC W Double Screw (DC only)
WE Double Screw with 3 Amp Diode (DC Only)
Bodies &
Cavities

Y Single Screw (Internally Grounded, DC Only)


Note: Additional voltages and other terminals are available. Some coils are UL
approved. For details please consult factory.
TD DIN Female Mating Connector: See page CL2
Deutsch Mating Connector: # DT06-25
Technical

Packard Male Weather Pack Connector: 12010973


Packard Female Weather Pack Connector: 12015792
Data

CE5 Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3501/US Super Coil
Technical Information Series 5/8″″ I.D.
CV
Terminal Styles and Dimensions

Valves
Check
22.0
(0.86) L - Double Lead A - Amp Junior
S - Double Spade 18 gauge 457mm 18" long AD - Amp Junior
black color
with 3 Amp Diode SH
(+ and - metered)
36.0

Shuttle
Valves
(1.43)

MADEINU.S.A.
PAT.XXXXXXX

MADEINU.S.A.
PAT.XXXXXXX
CAX XXX H

CAX XXX H

MADEINU.S.A.
PAT.XXXXXXX
XXVDC XXW

XXVDC XXW

CAX XXX H
XXVDC XXW
LM

Load/Motor
16 Ø (.64) I.D.

Controls
43.0 60.0 57.0 71.0
(1.71) (2.36) (2.23) (2.79) FC

Controls
Y - Single Screw LE - Double Lead
(Internal ground) with 3 Amp Diode

Flow
8-32 UNC screw & nut 18 gauge 457mm 18" long
W - Double Screw Red wire positive,
MADEINU.S.A.
PAT.XXXXXXX
CAX XXX H
XXVDC XXW

50.0 8-32 UNC screw & nut Black wire negative


Diode protection from PF - Female PM - Male PC
(1.97) WE - Double Screw Packard Packard
positive to negative
with 3 Amp Diode Connector Connector

Pressure
Controls
(+ and - metered)

LE
MADEINU.S.A.
PAT.XXXXXXX

MADEINU.S.A.
PAT.XXXXXXX
CAX XXX H

CAX XXX H
XXVDC XXW

XXVDC XXW
Part No. Voltage

Elements
Logic
61.0 57.0
DC

Directional
(2.40) (2.23)
178.0

Controls
(7.0)
H - Integral Deutsch
C - Double Lead DT04 - 2P - EP04
Conduit (1/2" NPTF) HE - Integral Deutsch D - DIN 43650
18 gauge 457mm 18" long, black color (ground wire on AC only) MV
with 3 Amp Diode
(+ and - metered)

MADEINU.S.A.
PAT.XXXXXXX
CAX XXX H
XXVDC XXW

Manual
Valves
MADEINU.S.A.
PAT.XXXXXXX
MADEINU.S.A.
PAT.XXXXXXX

MADEINU.S.A.
PAT.XXXXXXX
CAX XXX H
CAX XXX H

CAX XXX H
XXVDC XXW
XXVDC XXW

XXVDC XXW

SV
57.0

Solenoid
(2.23)

Valves
79.0 66.5 68.0
(3.12) (2.62) (2.68) PV

Proportional
NOTES:

Valves
1. The standard A.C. coil includes a molded-in full wave rectifier rated for 800 peak reverse voltage.
2. All P Puissant (high wattage) coils use a red ring as an indiction marker on the terminal boss. (No ring on Integral Deutsch connector.)
CE
Electronics
Coils &

BC
Bodies &
Cavities

TD
Technical
Data

CE6 Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3501/US Unicoil
Technical Information Series 1/2″″ I.D.
CV
Features
• Compact one piece encapsulated design
Valves
Check

• Minimal amperage draw


SH • Numerous terminals and voltages Standard
(Without Diode)
• Coil designed for use with series DSL
and DSH type valves only
Shuttle
Valves

• Coils made with high quality Class N magnet wire

LM • Superior thick internal iron frame surrounding copper


windings to increase the flux density
Optional
(With Diode Consult Factory)
Load/Motor

• More ampere turns to deliver more magnetic flux per


Controls

input voltage
Ordering Information
• A.C. coil operates @ 50/60 cycle (Hz)
FC
Specifications S8 L
Controls
Flow

Wattage 14 Watts
Unicoil Wattage Termination Diode Voltage
Duty Rating Continuous @ 100% voltage 1/2″″ I.D.
PC
Wire Class Class N - 200°C (392°F)
Pressure
Controls

Heat Rise 45°C (115°F) over ambient Code Wattage Code Termination
A.C. Rectifier Integral full wave bridge L 14 Watt C *Conduit
Lead Wire 18 gauge 24″ long, 600 volt rating D *DIN Plug Face
LE Code Diode J Amp Jr.
Lead Wire 34 kg (75 lbs.) @ 21°C (70°F) &
Omit Without Diode M Metri-Pack
Elements

Strain Relief 18 kg (40 lbs.) @ 93°C (200°F)


R Diode P *Dual Spade
Logic

Encapsulating Rynite, resistant to moisture,


Material caustic solutions, fungus, Diode not available with all S *Dual Screw
and temperatures from connectors.
DC W Dual Lead
-40°C (-40°F) to 200°C (392°F) WS Weather Pack Shroud 24″
Directional
Controls

Finish Coil - Black *Diode not available


Frame - Yellow zinc dichromate
Code Voltage Current Resistance Lead
MV Amps Ohms Color
Coil Accessories For DIN Connector 43650
*D006 6 VDC 2.40 2.5 Black
Cable Gland 1.57 .39
Manual
Valves

*D010 10 VDC 1.45 6.9 Yellow


Type Non-Rectified Rectified D012 12 VDC 1.17 10.2 Red
PG9 710549-00 712126-01 1.04
SV *D018 18 VDC 0.84 21.5 Gray
PG11 710549-01 712126-00
D024 24 VDC 0.57 41.8 Blue
Solenoid

*D036 36 VDC 0.45 80.5 Orange


Valves

.06
1.04 *D048 48 VDC 0.32 150.6 Green
A120 120 VAC 0.16 663 Brown
PV A240 240 VAC 0.07 3032 White
Proportional

1.04
* Consult Factory.
Valves

Conduit Rectified Conduit Non-Rectified


CE
712704-00 710549-02
Electronics
Coils &

2.45 1.57

BC 1.04
1.37
.06
Bodies &
Cavities

.06 .22
1.06 .22 1.04

TD
Technical

1.06 Ø 1.00 1.04


Data

CE7 Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3501/US Unicoil
Technical Information Series 1/2″″ I.D.
CV
Terminal Styles and Dimensions

Valves
Check
1.671 1.155 1.671 0.875 1.671 0.896
0.881 0.881 0.881
SH
0.42

Shuttle
Valves
1.312 1.18 1.312 1.18 1.312

Double Lead ISO Standard


Type C - Male
Nut Side 1/2" NPTF Nut Side DIN 43650 Nut Side Connector LM
Plug Face Only

Load/Motor
Controls
1.752 1.602 1.752 1.602 1.752 1.602
1.49 1.47 1.20

0.080 0.080 0.080 0.564 FC


Cartridge Side Cartridge Side Cartridge Side

Type C Type D Type J

Controls
Conduit DIN Plug Face 43650 Amp Jr.

Flow
PC

Pressure
Controls
1.671 1.233 1.671 0.50 1.671 0.545
0.881 0.881 0.881

1.312 1.316 1.312 0.860 1.180 1.312 0.995 LE

Elements
Packard Thru Holes 8-32 Screw

Logic
Nut Side #12162269 Nut Side Tinned Brass Nut Side and Nut
SAE 1B-0.25

1.752 1.602 1.752 1.602 1.506 1.752 1.602 1.584 DC


1.20 1.120 1.20

Directional
Controls
0.080 0.080 0.080
Cartridge Side Cartridge Side Cartridge Side

Type M Type P Type S


Metri-Pack 150.2 Series Dual Spade Double Screw MV
Mating Connector 12162193

Manual
Valves
1.671 0.390 0.390
SV
1.671
0.881 0.881

Solenoid
Valves
1.312 0.660 1.312 0.660

18 Gauge 18 Gauge PV
24" Long Nut Side 24" Long

Proportional
Nut Side

Valves
1.752 1.602 1.752 1.602 Code Connector
1.355 1.335
WS 24" Leads
WS6 6" Leads
0.080
CE
0.080
Electronics
Cartridge Side Cartridge Side
Coils &

Type W Type WS
Dual Lead Weather Pack Shroud 12010973
Mating Connector 12015792
BC
Bodies &
Cavities

TD
Technical
Data

CE8 Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3501/US Unicoil
Technical Information Series 5/8″″ I.D.
CV
Features
• Compact one piece encapsulated design
Valves
Check

• Minimal amperage draw


SH • Numerous terminals and voltages Standard
(Without Diode)
• Coil designed for use with series DSL
and DSH type valves only
Shuttle
Valves

• Coils made with high quality Class N magnet wire

LM • Superior thick internal iron frame surrounding copper


windings to increase the flux density Optional
Load/Motor

(With Diode Consult Factory)


• More ampere turns to deliver more magnetic flux per
Controls

input voltage
Ordering Information
• A.C. coil operates @ 50/60 cycle (Hz)
FC
Specifications S10 L
Controls
Flow

Wattage 20 Watts
Unicoil Wattage Termination Diode Voltage
Duty Rating Continuous @ 100% voltage 5/8″″ I.D.
PC
Wire Class Class N - 200°C (392°F)
Pressure
Controls

Heat Rise 45°C (115°F) over ambient Code Wattage Code Termination
A.C. Rectifier Integral full wave bridge L 20 Watt C *Conduit
Lead Wire 18 gauge 24″ long, 600 volt rating D *DIN Plug Face
LE Code Diode J Amp Jr.
Lead Wire 34 kg (75 lbs.) @ 21°C (70°F) &
Omit Without Diode M Metri-Pack
Elements

Strain Relief 18 kg (40 lbs.) @ 93°C (200°F)


R Diode P *Dual Spade
Logic

Encapsulating Rynite, resistant to moisture,


Material caustic solutions, fungus, Diode not available with all S *Dual Screw
and temperatures from connectors.
DC W Dual Lead
-40°C (-40°F) to 200°C (392°F) WS Weather Pack Shroud 24″
Directional
Controls

Finish Coil - Black *Diode not available


Frame - Yellow zinc dichromate
Code Voltage Current Resistance Lead
MV Amps Ohms Color
Coil Accessories For DIN Connector 43650
*D006 6 VDC 3.33 1.8 Black
Cable Gland 1.57 .39
Manual
Valves

*D010 10 VDC 2.10 4.8 Yellow


Type Non-Rectified Rectified D012 12 VDC 1.67 7.2 Red
PG9 710549-00 712126-01 1.04
SV *D018 18 VDC 1.21 14.9 Gray
PG11 710549-01 712126-00
D024 24 VDC 0.88 27.4 Blue
Solenoid

*D036 36 VDC 0.61 58.9 Orange


Valves

.06
1.04 *D048 48 VDC 0.47 102.4 Green
A120 120 VAC 0.192 626 Brown
PV A240 240 VAC 0.10 2400 White
Proportional

1.04
* Consult Factory.
Valves

Conduit Rectified Conduit Non-Rectified


CE
712704-00 710549-02
Electronics
Coils &

2.45 1.57

BC 1.04
1.37
.06
Bodies &
Cavities

.06 .22
1.06 .22 1.04

TD
Technical

1.06 Ø 1.00 1.04


Data

CE9 Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3501/US Unicoil
Technical Information Series 5/8″″ I.D.
CV
Terminal Styles and Dimensions

Valves
Check
1.927 1.927 1.927
SH
1.025 1.025 1.025
1.145 0.865 0.886

Shuttle
Valves
1.470 1.180 1.470 1.180 1.470

Double Lead ISO Standard


Nut Side 1/2" NPTF Nut Side
DIN 43650
Nut Side Type C LM
Male

Load/Motor
Plug Face Only

Controls
2.124 1.964 2.124 1.964 2.124 1.964
1.505 1.485
1.215

0.080 0.080 0.579


0.080 Cartridge Side Cartridge Side Cartridge Side FC
Type C Type D Type J

Controls
Conduit DIN Plug Face 43650 Amp Jr.

Flow
PC

Pressure
Controls
1.927 1.927 1.927
1.025 1.025 1.025
1.231 0.490 0.535
LE
1.470 1.385 1.470 0.860 1.180 1.470 0.995

Elements
Thru Holes 8-32 Screw

Logic
Nut Side 1216229 Nut Side Nut Side
Tinned Brass and Nut
SAE 18-0.25

2.124 1.964 2.124 1.964


1.521
2.124 1.964
1.599
DC
1.215 1.135 1.215

Directional
Controls
0.080 Cartridge Side 0.080 Cartridge Side 0.080 Cartridge Side

Type M Type P Type S


Metri-Pack 150.2 Series Dual Spade Double Screw MV
Mating Connector 12162193

Manual
Valves
1.927 1.927
SV
1.025 1.025

Solenoid
0.380 0.380

Valves
1.470 0.652 1.470 0.652

18 Gauge 18 Gauge
PV
Nut Side Nut Side

Proportional
24" Long 24" Long

Valves
2.124 1.964 2.124 1.964 Code Connector
1.370 1.370 WS 24" Leads
WS6 6" Leads
0.080
CE
0.080 Cartridge Side Cartridge Side
Electronics

Type W Type WS
Coils &

Dual Lead Weather Pack Shroud 12010973


Mating Connector 12015792
BC
Bodies &
Cavities

TD
Technical
Data

CE10 Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3501/US DS Coil
Technical Information Series 1/2″″ I.D.
CV
Features
Valves


Check

Compact one piece encapsulated design

SH • Minimal amperage draw

• Numerous terminals and voltages


Shuttle
Valves

• High watt design available for intermittent operation


LM
• Heavy gauge color coded lead wire with built-in strain
Load/Motor

relief
Controls

• 180°C Class H wire standard

FC • 200°C Class N wire on high watt models


Controls
Flow

Specifications
PC
Wattage 12 Watts — Standard - Black Coil
25 Watts — High Watt - Red Coil
Pressure
Controls

Duty Rating Continuous @ 100% voltage


LE Symbol
Wire Class Class H for all voltages 12 Watt
Elements

Class N for all voltages 25 Watt


Logic

A.C. Rectifier Integral full wave bridge


DC
Lead Wire 18 gauge 24″ long, 600 volt rating
Directional
Controls

Lead Wire 34 kg (75 lbs.) @ 21°C (70°F) &


Strain Relief 18 kg (40 lbs.) @ 93°C (200°F)
MV
Encapsulating Glass filled nylon, resistant to
Material moisture, caustic solutions, fungus,
Manual
Valves

and temperatures from


-40°C (-40°F) to 200°C (392°F)
SV
Solenoid
Valves

AC Coil Assembly
No inductive or capacitive loads can be installed NOTE:
PV
between surge suppressor and rectified valves. Parker A.C. Coils incorporate integrally molded full
Proportional

wave rectifiers which are rated for reverse voltage


Valves

AC Coil Assembly peaks of 1000 volts maximum. For voltage transients


greater than 1000 volts P.I.V., Harris Thyrector
CE V150LA10A or V150LA20A for 115 VAC and
Electronics

V250LA15A or V250LA40A for 200 VAC is


Coils &

recommended.

BC
Bodies &
Cavities

Voltage Surge
Suppressor (Thyrector)
TD
Technical
Data

CE11 Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3501/US DS Coil
Technical Information Series 1/2″″ I.D.
CV
Terminal Styles and Dimensions

Valves
Check
13.0 (.50) I.D.
Type P Type W Type C
Dual Spade Dual Lead Double Lead With
Thru Hole Conduit Connector
28.6 Tinned Brass 18 Gauge (1/2" NPTF) 18 Gauge SH
(1.13) SAE 1B-0.25 24" Long 24" Long

Shuttle
Valves
Voltage
Part No.
33.5 25.8 40.4 LM

Load/Motor
(1.32) (1.02) (1.59)
37.1

Controls
(1.46)
Type D Type S Type J
DIN Double Screw AMP Junior
Timer Type C
DIN 43650 8-32 Screw FC
33.7 Plug Face Only & Nut
(1.33)

Controls
Flow
36.6 33.1 40.8 PC
(1.44) (1.31) (1.61)

Pressure
NOTES:

Controls
1. Coil to be installed with part number on nut side.
2. For additional terminals, voltages and wattages,
consult factory for details. LE

Elements
Logic
DC
Coil Part Numbers

Directional
Controls
Type P Type W Type C Type D Type S
Double Double Conduit DIN Double Lead Wire
Voltage Watts Spade Lead Connector Plug Face Screw Amps† Color
MV
**6 VDC 12 851007-006 851009-006 851003-006* 851005-006* 851011-006 2.22 Black
25 851008-006 851010-006 851004-006 851006-006 851012-006 3.90

Manual
Valves
**10 VDC 12 851007-010 851009-010 851003-010* 851005-010* 851011-010 1.43 Yellow
25 851008-010 851010-010 851004-010 851006-010 851012-010 2.48
SV
12 VDC 12 851007-012 851009-012 851003-012* 851005-012* 851011-012 1.05 Red

Solenoid
25 851008-012 851010-012 851004-012 851006-012 851012-012 1.94

Valves
**18 VDC 12 851007-018 851009-018 851003-018* 851005-018* 851011-018 0.75 Gray
25 851008-018 851010-018 851004-018 851006-018 851012-018 1.42
24 VDC 12 851007-024 851009-024 851003-024* 851005-024* 851011-024 0.52 Blue
PV

Proportional
25 851008-024 851010-024 851004-024 851006-024 851012-024 1.17

Valves
**36 VDC 12 851007-036 851009-036 851003-036* 851005-036* 851011-036 0.38 Orange
25 851008-036 851010-036 851004-036 851006-036 851012-036 0.73
**48 VDC 12 851007-048 851009-048 851003-048* 851005-048* 851011-048 0.26 Green CE
Electronics

25 851008-048 851010-048 851004-048 851006-048 851012-048 0.59


Coils &

120 VAC 12 851003-120 851005-120 0.14 Brown


25 851004-120 851006-120 0.23
230 VAC 12 851003-240 851005-240 0.08 White BC
25 851004-240 851006-240 0.12
Bodies &
Cavities

**440 VAC 12 851003-480 851005-480 0.04 Violet


25 851004-480 851006-480 0.07
**Consult Factory *UL Listed †Amperage draw @ 21°C (70°F) TD
Technical
Data

CE12 Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3501/US DS Coil
Technical Information Series 5/8″″ I.D.
CV
Features

Valves

Compact one piece encapsulated design


Check

• Minimal amperage draw


SH
• Numerous terminals and voltages

• High watt design optional


Shuttle
Valves

• Heavy gauge color coded lead wire with built-in strain


relief
LM
Load/Motor

• 180°C Class H wire standard


Controls

• 200°C Class N wire on high watt models

FC
Specifications
Controls
Flow

Wattage 17 Watts — Standard - Black Coil


30 Watts — High Watt - Red Coil
PC
Duty Rating Continuous @ 100% voltage
Pressure
Controls

Wire Class Class H for all voltages 17 Watt


Class N for all voltages 30 Watt
LE Symbol
A.C. Rectifier Integral full wave bridge
Elements
Logic

Lead Wire 18 gauge 24″ long, 600 volt rating


DC
Lead Wire 34 kg (75 lbs.) @ 21°C (70°F) &
Directional

Strain Relief 18 kg (40 lbs.) @ 93°C (200°F)


Controls

Encapsulating Glass filled nylon, resistant to


Material moisture, caustic solutions, fungus,
MV
and temperatures from
-40°C (-40°F) to 200°C (392°F)
Manual
Valves

SV
AC Coil Assembly
Solenoid

No inductive or capacitive loads can be installed NOTE:


Valves

between surge suppressor and rectified valves. Parker A.C. Coils incorporate integrally molded full
wave rectifiers which are rated for reverse voltage
PV
AC Coil Assembly peaks of 1000 volts maximum. For voltage transients
Proportional

greater than 1000 volts P.I.V., Harris Thyrector


Valves

V150LA10A or V150LA20A for 115 VAC and


V250LA15A or V250LA40A for 200 VAC is
CE recommended.
Electronics
Coils &

BC
Voltage Surge
Bodies &

Suppressor (Thyrector)
Cavities

TD
Technical
Data

CE13 Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3501/US DS Coil
Technical Information Series 5/8″″ I.D.
CV
Terminal Styles and Dimensions

Valves
Check
16.0 (.63) I.D.
Type P Type W Type C
Dual Spade Dual Lead Double Lead With
Thru Hole Conduit Connector
31.7 Tinned Brass 18 Gauge
(1/2" NPTF) 18 Gauge SH
SAE 1B-0.25 24" Long
(1.25) 24" Long

Shuttle
Valves
Voltage
Part No.
40.6 38.4 28.6 42.2
LM

Load/Motor
(1.60) (1.51) (1.13) (1.66)

Controls
Type D Type J
DIN AMP Junior
Timer Type C
DIN 43650
45.0 Plug Face Only FC
(1.77)

Controls
Flow
40.2 40.8 PC
(1.58) (1.61)

Pressure
NOTES:

Controls
1. Coil to be installed with part number on nut side.
2. For additional terminals, voltages and wattages,
consult factory for details. LE

Elements
Logic
DC
Coil Part Numbers

Directional
Controls
Type P Type W Type C Type D
Double Double Conduit DIN Lead Wire
Voltage Watts Spade Lead Connector Plug Face Amps* Color
MV
6 VDC 17 851021-006 851023-006 851017-006 851019-006 2.43 Black
30 851022-006 851024-006 851018-006 851020-006 4.84

Manual
Valves
10 VDC 17 851021-010 851023-010 851017-010 851019-010 1.58 Yellow
30 851022-010 851024-010 851018-010 851020-010 3.28
SV
12 VDC 17 851021-012 851023-012 851017-012 851019-012 1.44 Red

Solenoid
30 851022-012 851024-012 851018-012 851020-012 2.30

Valves
18 VDC 17 851021-018 851023-018 851017-018 851019-018 0.94 Gray
30 851022-018 851024-018 851018-018 851020-018 1.86
24 VDC 17 851021-024 851023-024 851017-024 851019-024 0.72 Blue
PV

Proportional
30 851022-024 851024-024 851018-024 851020-024 1.20

Valves
36 VDC 17 851021-036 851023-036 851017-036 851019-036 0.43 Orange
30 851022-036 851024-036 851018-036 851020-036 0.88
48 VDC 17 851021-048 851023-048 851017-048 851019-048 0.30 Green CE
Electronics

30 851022-048 851024-048 851018-048 851020-048 0.58


Coils &

120 VAC 17 851017-120 851019-120 0.15 Brown


30 851018-120 851020-120 0.24
230 VAC 17 851017-240 851019-240 0.08 White BC
30 851018-240 851020-240 0.13
Bodies &
Cavities

440 VAC 17 851017-480 851019-480 0.04 Violet


30 851018-480 851020-480 0.07
*Amperage draw @ 21°C (70°F) TD
Technical
Data

CE14 Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3501/US DS Coil
Technical Information Series 1″″ I.D.
CV
Features
• Compact one piece encapsulated design
Valves
Check

• Numerous terminals and voltages

SH • Heavy gauge color coded lead wire with built-in strain


relief
• 200°C Class N wire standard
Shuttle
Valves

• U.L. recognized on most DC coils (consult factory)

LM Specifications
Load/Motor

Wattage 42 Watts — Standard


Controls

30 Watts — Low Watt


AC Coil Assembly
Duty Rating Continuous @ 100% voltage
FC No inductive or capacitive loads can be installed
Wire Class Class N for all voltages
between surge suppressor and rectified valves.
Controls

Lead Wire 18 gauge 24″ long, 600 volt rating


Flow

AC Coil Assembly
Lead Wire 34 kg (75 lbs.) @ 21°C (70°F) &
Strain Relief 18 kg (40 lbs.) @ 93°C (200°F)
PC
Encapsulating Glass filled nylon, resistant to
Pressure
Controls

Material moisture, caustic solutions, fungus,


and temperatures from
-40°C (-40°F) to 200°C (392°F)
LE Color Black
Elements

Voltage Surge
Logic

Terminal Styles and Dimensions Suppressor (Thyrector)

25.4 (1.00) I.D.


DC Type P Type W
Directional

Dual Spade Double Lead


Controls

Thru Hole
48.1 Tinned Brass 18 Gauge
(1.89) SAE 1B-0.25 24" Long

MV
Voltage
Part No.
Manual
Valves

56.0
(2.20)

SV 40.7 40.7
(1.60) (1.60)
Solenoid
Valves

59.8
(2.35) Type C Type D
Double Lead With ISO Standard
Conduit Connector
PV (1/2" NPTF) 18 Gauge DIN 43650
Plug Face Only
Proportional

24" Long
Valves

NOTES:
CE 1. Coil to be installed with part number on nut side.
Electronics

2. For additional terminals, voltages and wattages,


Coils &

consult factory for details. 51.8 50.6


(2.04) (1.99)

BC Coil Part Numbers


Type P Type W Type D Lead Wire
Bodies &
Cavities

Wattage Voltage Double Spade Double Lead ISO STANDARD Amps Color
42 Watts 12 VDC 851060-012* 851062-012* 851058-012* 3.53 Red
42 Watts 24 VDC 851060-024* 851062-024* 851058-024* 1.79 Blue
TD
30 Watts 12 VDC 853496-012 853497-012 853495-012 2.50 Red
Technical

30 Watts 24 VDC 853496-024 853497-024 853495-024 1.25 Blue


Data

*UL Listed

CE15 Parker Hannifin Corporation


Hydraulic Cartridge Systems
Notes
Catalog HY15-3501/US

CE16
DS Coil
Series 1″″ I.D.

Hydraulic Cartridge Systems


Parker Hannifin Corporation
Technical Bodies & Coils & Proportional Solenoid Manual Directional Logic Pressure Flow Load/Motor Shuttle Check
LE
FC

TD
CE
PV
SV
PC

Data Cavities Electronics Valves Valves Valves Controls Elements Controls Controls Controls Valves Valves
SH

BC
DC
CV

LM

MV
Catalog HY15-3501/US Proportional Valve Controller
Technical Information Series XPRO902, 932, 904, 934
CV
General Description
Valves

Proportional Valve Controllers. 12 and 24 Volts, PWM.


Check

For additional information see Technical Tips on pages I Max Adjustment


SH CE1-CE2. 0 - 100 %

Operation
Shuttle
Valves

The 902/932 and 904/934 are valve top mounted PWM


controllers for proportional control valves. They can be
LM
used with an external potentiometer to give accurate
Load/Motor

current control using the units internal reference


Controls

Output LED
voltage. Alternatively these controllers can be used
with a 0-10V command signal from a PLC or engine
FC management system.
‘I Max’ adjustment is provided to allow the maximum
Controls
Flow

output current to be set via a 12 turn potentiometer. V


Turn clockwise to increase the output current. I
PC
Notes:
Pressure

XPRO902 and XPRO932


Controls

In order to avoid damaging a controller the +8V


(yellow) lead must not be shorted to the +12V (red)
LE lead or to the 0V (blue) lead. Features

Elements

XPRO904 and XPRO934 Self contained DIN ‘Plug Top’


Logic

In order to avoid damaging a controller the +15V • High impact resistant molded ABS

DC
(yellow) lead must not be shorted to the +24V (red) • Complies with current CE regulations
lead or to the 0V (blue) lead.
Directional
Controls

Output Regulation
Specifications (Curve shows coil temperature compensation)
MV 0.7
Nominal XPRO902 12V DC
Voltage XPRO932 12V DC
Manual
Valves

XPRO904 24V DC 0.6


XPRO934 24V DC
SV
Maximum XPRO902 19W 0.5
Power XPRO932 30W
Solenoid
Valves

XPRO904 19W
XPRO934 30W
0.4
Current, A

PV (IP) Rating IP 65
Proportional

0.3
Maximum XPRO902 1.6A XPRO
Valves

Current XPRO932 2.6A


XPRO904 1.0A Non-XPRO
0.2
CE XPRO934 1.4A
Electronics

Command Voltage 0 - 10V


Coils &

0.1
Input Resistance 10K ohms
BC 0
Refference Voltage XPRO902 +8V (2mA) 0.5 2.5 4.5 6.5 8.5 10.5 12.5 14.5 16.5 18.5
Bodies &

XPRO932 +8V (2mA)


Cavities

Time, minutes
XPRO904 +15V (2mA)
XPRO934 +15V (2mA)
TD Cable Length 1 meter
Application
For use with most proportional valves. GP, HP, JP, GTP
Technical

Frequency 110 Hz ±5% and AP series valves.


Data

CE17 Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3501/US Proportional Valve Controller
Technical Information Series XPRO902, 932, 904, 934
CV
Dimensions Millimeters (Inches) Ordering Information

Valves
Check
34.0 68.0
(1.34) (2.68) XPRO
SH
Controller Maximum
40.0 Current

Shuttle
Valves
(1.57)
Code Maximum Current
902 1.6A
LM
932 2.6A

Load/Motor
904 1.0A

Controls
934 1.4A

FC

Controls
Flow
Connection Details
PC
XPRO902 and XPRO932 XPRO904 and XPRO934

Pressure
Controls
10K Potentiometer 10K Potentiometer
Red: +12V Red: +24V
Yellow: +8V ref Yellow: +15V ref LE

Elements
Logic
Green: Command Green: Command

DC

Directional
Blue: 0V Blue: 0V Supply Blue: 0V Blue: 0V Supply

Controls
MV
From PLC From PLC
Red: +12V Red: +24V

Manual
Valves
Yellow: +8V ref (not used) Yellow: +15V ref (not used)

SV
0-10V Green: Command 0-10V Green: Command

Solenoid
Valves
0V 0V

Blue: 0V Blue: 0V Supply Blue: 0V Blue: 0V Supply


PV

Proportional
Valves
Controller / Coil Combination
CE
Electronics

Controller Controller
Coils &

Coil XPRO 902 XPRO 932 Coil XPRO 904 XPRO 934
CCS012D X CCS024D X
CCP012D X CCP024D X BC
CAS012D X CAS024D X
Bodies &
Cavities

CAP012D X CAP024D X

TD
Technical
Data

CE18 Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3501/US Proportional Valve Controller
Technical Information Series XPRO902d, 932d, 904d, 934d
CV
General Description
Proportional Valve Controllers. 12 and 24 Volts, PWM
Valves
Check

with Adjustable Dither. For additional information see


I Max Adjustment
Technical Tips on pages CE1-CE2. 0 - 100%
SH
Operation
Shuttle
Valves

The 902d/932d and 904d/934d are valve top mounted


PWM controllers for proportional control valves. They
LM can be used with an external potentiometer to give
Load/Motor

accurate current control using the units internal Frequency


Controls

reference voltage. Alternatively these controllers can Output LED


be used with a 0-10V command signal from a PLC or
FC
engine management system.
‘I Max’ adjustment is provided to allow the maximum
Controls

output current to be set via a 12 turn potentiometer.


Flow

Turn clockwise to increase the output current.


Dither adjustment POT is used to alter the PWM V
PC I
frequency of the controller from 95 HZ to 230 Hz. By
Pressure
Controls

changing the frequency this pot controls the amount of


dither imposed on the valve. Lower frequency = more
dither, higher frequency = less dither. Turn clockwise to
LE increase frequency. Features

Elements

Notes: Self contained DIN ‘Plug Top’


Logic

XPRO902d and XPRO932d


In order to avoid damaging a controller the +8V
• High impact resistant molded ABS

DC (yellow) lead must not be shorted to the +12V (red)


• Complies with current CE regulations
Directional

lead or to the 0V (blue) lead.


Controls

XPRO904d and XPRO934d Output Regulation


In order to avoid damaging a controller the +15V (Curve shows coil temperature compensation)
MV (yellow) lead must not be shorted to the +24V (red) 0.7
lead or to the 0V (blue) lead.
Manual
Valves

0.6
Specifications
SV
Nominal XPRO902d 12V DC 0.5
Voltage XPRO932d 12V DC
Solenoid
Valves

XPRO904d 24V DC
XPRO934d 24V DC 0.4
Current, A

PV Maximum XPRO902d 19W


Power XPRO932d 30W
Proportional

XPRO904d 19W 0.3 XPRO


Valves

XPRO934d 30W
(IP) Rating IP 65 Non-XPRO
0.2
CE Maximum XPRO902d 1.6A
Electronics

Current XPRO932d 2.6A


Coils &

XPRO904d 1.0A 0.1


XPRO934d 1.4A
Command Voltage 0 - 10V
BC 0
Input Resistance 10K ohms 0.5 2.5 4.5 6.5 8.5 10.5 12.5 14.5 16.5 18.5
Bodies &
Cavities

Refference Voltage XPRO902d +8V (2mA) Time, minutes


XPRO932d +8V (2mA)
XPRO904d +15V (2mA)
TD XPRO934d +15V (2mA) Application
Cable Length 1 meter For use with most proportional valves. GP, HP, JP, GTP
Technical

Frequency 95 Hz - 230 Hz and AP series valves.


Data

CE19 Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3501/US Proportional Valve Controller
Technical Information Series XPRO902d, 932d, 904d, 934d
CV
Dimensions Millimeters (Inches) Ordering Information

Valves
Check
34.0 68.0
(1.34) (2.68) XPRO
SH
Controller Maximum
40.0 Current

Shuttle
Valves
(1.57)
Code Maximum Current
902d 1.6A
LM
932d 2.6A

Load/Motor
904d 1.0A

Controls
934d 1.4A
Setting for standard:
Dither frequency: 110 HZ
FC

Controls
Flow
Connection Details
PC
XPRO902d and XPRO932d XPRO904d and XPRO934d

Pressure
Controls
10K Potentiometer 10K Potentiometer
Red: +12V Red: +24V
Yellow: +8V ref Yellow: +15V ref LE

Elements
Logic
Green: Command Green: Command

DC

Directional
Blue: 0V Blue: 0V Supply Blue: 0V Blue: 0V Supply

Controls
MV
From PLC From PLC
Red: +12V Red: +24V

Manual
Valves
Yellow: +8V ref (not used) Yellow: +15V ref (not used)

SV
0-10V Green: Command 0-10V Green: Command

Solenoid
Valves
0V 0V

Blue: 0V Blue: 0V Supply Blue: 0V Blue: 0V Supply


PV

Proportional
Valves
Controller / Coil Combination
CE
Electronics

Controller Controller
Coils &

Coil XPRO 902d XPRO 932d Coil XPRO 904d XPRO 934d
CCS012D X CCS024D X
CCP012D X CCP024D X BC
CAS012D X CAS024D X
Bodies &
Cavities

CAP012D X CAP024D X

TD
Technical
Data

CE20 Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3501/US Proportional Valve Controller
Technical Information Series XPRO902rid, 932rid, 904rid, 934rid
CV
General Description
Proportional Valve Controllers. 12 and 24 Volts, PWM
Valves
Check

with Multiple Adjustments. For additional information


see Technical Tips on pages CE1-CE2. Output LED I Max Adjustment
SH 0 - 100%

Operation
Shuttle
Valves

The 902rid/932rid and 904rid/934rid are valve top


mounted PWM controllers for proportional control
valves. They can be used with an external potentiom-
LM
eter to give accurate current control using the units
Load/Motor

internal reference voltage. Alternatively these control- Ramp Down Frequency


Controls

lers can be used with a 0-10V command signal from a Ramp Up I min 0 - 50%
PLC or engine management system.
FC ‘I’ Max adjustment is provided to allow the maximum
output current to be set via a 12 turn potentiometer.
Controls

Turn clockwise to increase the output current.


Flow

Ramp Up and Ramp Down adjustments provide


independent, linear control of the time it takes, to V
PC reach ‘I’ Max and to switch off, up to 8 seconds of I
delay. Turn clockwise for slower ramps.
Pressure
Controls

‘I’ Min adjustment Pot sets the minimum current the


controller will jump to when a command signal is
LE present, used to eliminate dead band in a slow ramp. Features
Turn clockwise for a higher ‘I’ Min setting.

Elements

Self contained DIN ‘Plug Top’


Dither adjustment Pot is used to alter the PWM
Logic

frequency of the controller from 95 HZ to 230 Hz. By • High impact resistant molded ABS

DC
changing the frequency this pot controls the amount of
dither imposed on the valve. Lower frequency = more
• Complies with current CE regulations
Directional

dither, higher frequency = less dither. Turn clockwise to


Controls

increase frequency. Output Regulation


Notes: (Curve shows coil temperature compensation)
MV XPRO902rid and XPRO932rid 0.7
In order to avoid damaging a controller the +8V
(yellow) lead must not be shorted to the +12V (red)
Manual
Valves

lead or to the 0V (blue) lead. 0.6


XPRO904rid and XPRO934rid
SV In order to avoid damaging a controller the +15V
(yellow) lead must not be shorted to the +24V (red) 0.5
Solenoid

lead or to the 0V (blue) lead.


Valves

0.4
Current, A

PV
Specifications
Proportional

Nominal XPRO902rid & 932rid 12V DC


0.3 XPRO
Valves

Voltage XPRO904rid & 934rid 24V DC


Maximum XPRO902rid & 904rid 19W
Power XPRO932rid & 934rid 30W Non-XPRO
0.2
CE
(IP) Rating IP 65
Electronics
Coils &

Maximum XPRO902rid 1.6A 0.1


Current XPRO932rid 2.6A
XPRO904rid 1.0A
BC XPRO934rid 1.4A 0
Command Voltage 0 - 10V 0.5 2.5 4.5 6.5 8.5 10.5 12.5 14.5 16.5 18.5
Bodies &
Cavities

Time, minutes
Input Resistance 10K ohms
Refference Voltage XPRO902rid & 932rid +8V (2mA)
TD XPRO904rid & 934rid +15V (2mA) Application
Cable Length 1 meter For use with most proportional valves. GP, HP, JP, GTP
Technical

Ramp Up/Down 200ms - 8s and AP series valves.


Data

CE21 Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3501/US Proportional Valve Controller
Technical Information Series XPRO902rid, 932rid, 904rid, 934rid
CV
Dimensions Millimeters (Inches) Ordering Information

Valves
Check
34.0 68.0
(1.34) (2.68) XPRO
SH
Controller Maximum
40.0 Current

Shuttle
Valves
(1.57)
Code Maximum Current
902rid 1.6A
LM
932rid 2.6A

Load/Motor
904rid 1.0A

Controls
934rid 1.4A
Setting for standard:
Dither frequency: 110 HZ
FC

Controls
Flow
Connection Details
PC
XPRO902rid and XPRO932rid XPRO904rid and XPRO934rid

Pressure
Controls
10K Potentiometer 10K Potentiometer
Red: +12V Red: +24V
Yellow: +8V ref Yellow: +15V ref LE

Elements
Logic
Green: Command Green: Command

DC

Directional
Blue: 0V Blue: 0V Supply Blue: 0V Blue: 0V Supply

Controls
MV
From PLC From PLC
Red: +12V Red: +24V

Manual
Valves
Yellow: +8V ref (not used) Yellow: +15V ref (not used)

SV
0-10V Green: Command 0-10V Green: Command

Solenoid
Valves
0V 0V

Blue: 0V Blue: 0V Supply Blue: 0V Blue: 0V Supply


PV

Proportional
Valves
Controller / Coil Combination
CE
Electronics

Controller Controller
Coils &

Coil XPRO 902rid XPRO 932rid Coil XPRO 904rid XPRO 934rid
CCS012D X CCS024D X
CCP012D X CCP024D X BC
CAS012D X CAS024D X
Bodies &
Cavities

CAP012D X CAP024D X

TD
Technical
Data

CE22 Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3501/US Soft Start Valve Controller
Technical Information Series XPRO704
CV
General Description
Soft Start Valve Controller. 12 and 24 Volt PWM.
Valves
Check

For additional information see Technical Tips on


pages CE1-CE2.
SH
Features XPRO
Shuttle
Valves

704
• Self contained DIN PWM ‘Plug Top’

LM
• High impact resistant moulded ABS
• Supplied with approximately 1 meter of two color coded
Load/Motor

cables
Controls

• Can be used with 12V DC and 24V DC coils

FC
• Fixed I-second ramp upon engagement

Operation
Controls

The 704 is a soft start plug top PWM controller used


Flow

for reducing the hydraulic pressure peaks produced


PC when a hydraulic valve is operated. It can simply be
used in place of a standard DIN connector.
Pressure
Controls

Output Voltage
12/24V
LE Dimensions Millimeters (Inches)
Elements

48.0
Logic

(1.90)
Voltage To Coil

DC
Directional

XPRO 28.0
Controls

704 (1.10)

MV

0 0.5 1.0 1.5 2.0


Manual
Valves

Time sec
Connection Details
SV
Application
For use with most proportional valves. GP, HP, JP, GTP
Solenoid

and AP series valves. Brown + 12V / 24V


Valves

XPRO
PV
Specifications Blue 0V Supply 704
Proportional

Nominal Voltage 12V DC and 24V DC


Valves

Maximum Power 36W

CE (IP) Rating IP 65
Controller / Coil Combination
Electronics

Maximum Current 3.0A XPRO 704 can be used with all 12V DC and 24V DC
Coils &

Coil Resistance 4.5 - 30 ohms DIN coils.

BC Ramp Up Fixed 1000ms Ordering Information


Bodies &
Cavities

XPRO 704
TD Controller Plug Type
Technical

Code Plug Type


704 Soft Start
Data

CE23 Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3501/US Soft Start/Stop Valve Controller
Technical Information Series XPRO704b
CV
General Description
Soft Start/Stop Valve Controller. 12 and 24 Volts, PWM

Valves
Check
Step point up Step point down
with Adjustable Ramps. For additional information see
Technical Tips on pages CE1-CE2.
SH
Features

Shuttle
Valves
• Adjustable ramp to engage and disengage
• Self contained DIN ‘Plug Top’
LM
• High impact resistant moulded ABS Ramp rate up Ramp rate down

Load/Motor
Controls
Operation
The 704b is a valve top mounted ‘soft start, soft stop’
controller for use with a range of valves. FC
The controller can be set to jump to a preset ‘step’

Controls
voltage then ramp up to maximum at a preset rate. It

Flow
can also be set to jump down to a preset ‘step’ voltage
and ramp down to zero. This can be used to eliminate PC
‘bangs’ or hydraulic shocks associated with operating a

Pressure
Controls
hydraulic valve.

Output Voltage Dimensions Millimeters (Inches)


34.0 68.0 LE
Control Signal On (1.34) (2.68)

Elements
Logic
34.0
Voltage To Coil

Ramp (1.34)
Rate Up DC

Directional
Controls
Step Up Step Down
Set Point Set Point

Control Ramp Rate MV


Signal Off Down

Manual
Valves
Time
Application
For use with most proportional valves. GP, HP, JP, GTP Connection Details SV
and AP series valves. Connect to

Solenoid
Switch

Valves
Brown: +12V / +24V
Specifications
Nominal Voltage 12V DC and 24V DC PV
Green/Yellow: Control

Proportional
Maximum Power 36W

Valves
Blue: 0V Supply
(IP) Rating IP 65
CE
Maximum Current 3.0A Controller / Coil Combination
Electronics

XPRO 704b can be used with all 12V DC and 24V DC


Coils &

Coil Resistance 4.8 - 30 ohms


DIN coils.
Coil Voltage +V Supply
Ordering Information BC
Control Resistance 820 ohms
Bodies &
Cavities

Cable Length 1 meter


XPRO 704b
Step Up Adjust 10 - 80%
Controller Plug Type TD
Step Down Adjust 10 - 80%
Technical

Code Plug Type


Ramp Up/Down 200ms - 4s 704b Soft Start, Soft Stop
Data

CE24 Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3501/US Power Saver Controller
Technical Information Series XPRO804
CV
General Description
Power Saver Controller. 12 and 24 Volt, PWM.
Valves
Check

For additional information see Technical Tips on


pages CE1-CE2.
SH
Features XPRO
Shuttle
Valves

804
• Reduced power consumption and heat generation

LM
• Self contained DIN ‘Plug Top’
• High impact resistant moulded ABS
Load/Motor


Controls

Supplied with approximately 1 meter of two color coded


cables

FC Operation
The 804 is a power saver plug top PWM controller
Controls

used for reducing the current consumption of a stan-


Flow

dard on/off valve. The plug will deliver full voltage to


the valve for 50mS then drop down to a holding
PC
voltage of 30% of the applied voltage. This can be
Pressure

used where multiple valves are used and power


Controls

consumption is a consideration. It can simply be used


in place of a standard DIN connector.
LE Dimensions Millimeters (Inches)
Voltage Applied To Coil
Elements

48.0
Logic

(1.90)

DC
Directional

XPRO 28.0
Controls

804 (1.10)
Voltage, V

MV
Manual
Valves

Connection Details
0 50 100 150 200 250
SV
Time minutes
Solenoid

Brown + 12V / 24V


Valves

Application
XPRO
PV For use with most on/off valves. GO, GS series valves. Blue 0V Supply 804
Proportional

Specifications
Valves

Nominal Voltage 12V DC and 24V DC


CE
Controller / Coil Combination
Electronics

Maximum Power 36W


XPRO 804 can be used with all 12V DC and 24V DC
Coils &

(IP) Rating IP 65 coils.


Maximum Current 3.0A
BC Ordering Information
Coil Resistance 4.5 - 30 ohms
Bodies &
Cavities

Current Reduction 30% of Max XPRO 804


TD Controller Plug Type
Technical

Code Plug Type


804 Power Saver Plug
Data

CE25 Parker Hannifin Corporation


Hydraulic Cartridge Systems
Notes
Catalog HY15-3501/US

CE26
Series XPRO804
Power Saver Controller

Hydraulic Cartridge Systems


Parker Hannifin Corporation
Technical Bodies & Coils & Proportional Solenoid Manual Directional Logic Pressure Flow Load/Motor Shuttle Check
LE
FC

TD
CE
PV
SV
PC

Data Cavities Electronics Valves Valves Valves Controls Elements Controls Controls Controls Valves Valves
SH

BC
DC
CV

LM

MV