LECTURE NOTES
(AEE018)
Prepared By:
1
INSTITUTE OF AERONAUTICAL ENGINEERING
(AUTONOMOUS)
Dundigal, Hyderabad -500 043.
DEPARTMENT OF MECHANICAL ENGINEERING
LECTURE NOTES:
SYLLABUS:
UNIT-I
ELECTRIC CIRCUITS, ELECTROMAGNETISM AND INSTRUMENTS:
Electrical Circuits: Basic definitions, types of elements, Ohm's Law, resistive networks,
inductive networks, capacitive networks, Kirchhoff's Laws, Series, parallel circuits and star
delta transformations, simple problems, Faradays law of electromagnetic induction;
Instruments: Basic principles of indicating instruments, permanent magnet moving coil and
moving iron instruments
UNIT-II
DC MACHINES
Principle of operation DC Generator, EMF equation, types, DC motor types, torque equation
applications, three point starter
UNIT-III
ALTERNATING QUANTITIES AND AC MACHINES
Alternating quantities: sinusoidal AC voltage, average, RMS, form and peak factor, concept of
three phase alternating quantity; Transformer: Principle of operation, EMF equation, losses,
efficiency and regulation.
Three phase induction motor: Principle of operation, slip, slip - torque characteristics,
efficiency and applications; Alternator: Principle of operation, EMF Equation, efficiency, and
regulation by synchronous impedance method.
UNIT-IV
SEMICONDUCTOR DIODE AND APPLICATIONS
Semiconductor diode: P-N Junction diode, symbol, V-I characteristics, half wave rectifier, full
wave rectifier, bridge rectifier and filters, diode as a switch, Zener diode as a voltage regulato
UNIT –V
BIPOLAR JUNCTION TRANSISTOR AND APPLICATIONS
2
Bipolar junction: DC characteristics, CE, CB, CC configurations, biasing, load line, Transistor
as an amplifier.
TEXT BOOKS:
1. David A. Bell, “Electronic Devices and Circuits”, Oxford University Press, 5th Edition,
2005.
2. M. Arshad, “Network Analysis and Circuits”, Infinity Science Press, 9th Edition, 2016.
3. A. Bruce Carlson, “Circuits”, Cengage Learning, 1st Edition, 2008.
4. S. Salivahanan, N. Suresh Kumar, A. Vallavaraj, “Electronic Devices and Circuits”,
Tata Mc Graw Hill, 2nd Edition, 2011.
3
UNIT – I
ELECTRIC CIRCUITS, ELECTROMAGNETISM AND INSTRUMENTS
1.1 INTRODUCTION
Given an electrical network, the network analysis involves various methods. The process of finding
the network variables namely the voltage and currents in various parts of the circuit is known as
network analysis. Before we carry out actual analysis it is very much essential to thoroughly
understand the various terms associated with the network. In this chapter we shall begin with the
definition and understanding in detail some of the commonly used terms. The basic laws such as
Ohm’s law, KCL and KVL, those can be used to analyse a given network Analysis becomes easier if
we can simplify the given network. We will be discussing various techniques, which involve
combining series and parallel connections of R, L and C elements.
One great advantage of SI unit is that it uses prefixes based on the power of 10 to relate larger and
smaller units to the basic unit.
1.3.1 CHARGE
The most basic quantity in an electric circuit is the electric charge. We all experience the effect of
electric charge when we try to remove our wool sweater and have it stick to our body or walk across a
carpet and receive a shock.
Charge is an electrical property of the atomic particles of which matter consists, measured in
coulombs (C). Charge, positive or negative, is denoted by the letter q or Q.
We know from elementary physics that all matter is made of fundamental building blocks known as
atoms and that each atom consists of electrons, protons, and neutrons. We also know that the charge
4
‘e’ on an electron is negative and equal in magnitude to 1.602x10-19 C, while a proton carries a
positive charge of the same magnitude as the electron and the neutron has no charge. The presence of
equal numbers of protons and electrons leaves an atom neutrally charged.
1.3.2 CURRENT
Current can be defined as the motion of charge through a conducting material, measured in Ampere
(A). Electric current, is denoted by the letter i or I.
The unit of current is the ampere abbreviated as (A) and corresponds to the quantity of total charge
that passes through an arbitrary cross section of a conducting material per unit second.
Mathematically,
Where is the symbol of charge measured in Coulombs (C), I is the current in amperes (A) and t is
the time in second (s).
The current can also be defined as the rate of charge passing through a point in an electric circuit.
Mathematically,
A constant current (also known as a direct current or DC) is denoted by symbol I whereas a time-
varying current (also known as alternating current or AC) is represented by the symbol or ( ).
Figure 1.1 shows direct current and alternating current.
Fig. 1.2Two common types of current: (a) direct current (DC), (b) alternative current (AC)
5
Example 1.1
Determine the current in a circuit if a charge of 80 coulombs passes a given point in 20 seconds (s).
Solution:
Example 1.2
How much charge is represented by 4,600 electrons?
Solution:
Each electron has - 1.602x10-19 C. Hence 4,600 electrons will have:
-1.602x10-19x4600 = -7.369x10-16 C
Example 1.3
The total charge entering a terminal is given by =5 sin4 . Calculate the current at =0.5 .
Solution:
At =0.5 .
= 31.42
Example 1.4
Determine the total charge entering a terminal between =1 and =2 if the current passing the
terminal is = (3 2− ) .
Solution:
Voltage (or potential difference) is the energy required to move charge from one point to the other,
measured in volts (V). Voltage is denoted by the letter v or V.
Mathematically,
6
where w is energy in joules (J) and q is charge in coulombs (C). The voltage ab or simply V is
measured in volts (V).
1 volt = 1 joule/coulomb = 1 newton-meter/coulomb
Fig. 1.3 shows the voltage across an element (represented by a rectangular block) connected to points
a and b. The plus (+) and minus (-) signs are used to define reference direction or voltage polarity.
The ab can be interpreted in two ways: (1) point a is at a potential of ab volts higher than point b, or
(2) the potential at point a with respect to point b is ab . It follows logically that in general
Example 1.5
An energy source forces a constant current of 2 A for 10 s to flow through a lightbulb. If 2.3 kJ is
given off in the form of light and heat energy, calculate the voltage drop across the bulb.
Solution:
Total charge dq= i*dt = 2*10 = 20 C
1.3. 4 POWER
Power is the time rate of expending or absorbing energy, measured in watts (W). Power, is denoted by
the letter p or P.
Mathematically,
Where p is power in watts (W), w is energy in joules (J), and t is time in seconds (s).
Thus, ifthe magnitude of current I and voltage are given, then power can be evaluated as the product
of the two quantities and is measured in watts (W).
Sign of power:
7
Passive sign convention:
If the current enters through the positive polarity of the voltage, p = +vi
If the current enters through the negative polarity of the voltage, p = – vi
1.3.5 ENERGY
Energy is the capacity to do work, and is measured in joules (J).
The energy absorbed or supplied by an element from time 0 to t is given by,
The electric power utility companies measure energy in watt-hours (WH) or Kilo watt-hours (KWH)
1 WH = 3600 J
Example 1.6
A source e.m.f. of 5 V supplies a current of 3A for 10 minutes. How much energy is provided in this
time?
Solution:
= = 5 × 3 × 10 × 60 = 9
Example 1.7
An electric heater consumes 1.8Mj when connected to a 250 V supply for 30 minutes. Find the power
rating of the heater and the current taken from the supply.
Solution:
= / = (1.8×106)/ (30×60) = 1000
Power rating of heater = 1kW
=
Thus
= / =1000/250=4
Hence the current taken from the supply is 4A.
Example 1.7
Find the power delivered to an element at =3 if the current entering its positive terminals is
=5cos60 and the voltage is: (a) =3 , (b) =3didt.
Solution:
(a) The voltage is =3 =15cos60 ; hence, the power is: = =75cos260
At =3 ,
=75cos260 ×3×10−3 =53.48
8
At =3 ,
=−4500 sin0.18 cos0.18 =−6.396
Georg Simon Ohm (1787–1854), a German physicist, is credited with finding the relationship
between current and voltage for a resistor. This relationship is known as Ohm’s law.
Ohm’s law states that at constant temperature, the voltage (V) across a conducting material is directly
proportional to the current (I) flowing through the material.
Mathematically,
V I
V=RI
Wherethe constant of proportionality R is called the resistance of the material. The V-I relation for
resistor according to Ohm’s law is depicted in Fig.1.6
a) Active elements (Energy sources): The elements which are capable of generating or delivering
the energy are called active elements.
E.g., Generators, Batteries
b) Passive element (Loads): The elements which are capable of receiving the energy are called
passive elements.
E.g., Resistors, Capacitors and Inductors
9
1.5.1.1 INDEPENDENT SOURCES:
An ideal independent source is an active element that provides a specified voltage or current that is
completely independent of other circuit elements.
VL= VS - IL Rse
10
Fig. 1.9 Ideal Independent Current Source
IL = Is -Ish
An ideal dependent (or controlled) source is an active element in which the source quantity is
controlled by another voltage or current.
Dependent sources are usually designated by diamond-shaped symbols, as shown in Fig. 1.11. Since
the control of the dependent source is achieved by a voltage or current of some other element in the
circuit, and the source can be voltage or current, it follows that there are four possible types of
dependent sources, namely:
11
Fig. 1.11 Symbols for Dependent voltage source and Dependent current source
Dependent sources are useful in modeling elements such as transistors, operational amplifiers, and
integrated circuits. An example of a current-controlled voltage source is shown on the right-hand side
of Fig. 1.12, where the voltage 10i of the voltage source depends on the current i through element C.
Students might be surprised that the value of the dependent voltage source is 10i V (and not 10i A)
because it is a voltage source. The key idea to keep in mind is that a voltage source comes with
polarities (+ -) in its symbol, while a current source comes with an arrow, irrespective of what it
depends on.
Fig. 1.12 The source in right hand side is current-controlled voltage source
1.5.2.1 RESISTOR
Materials in general have a characteristic behavior of resisting the flow of electric charge. This
physical property, or ability to resist the flow of current, is known as resistance and is represented by
the symbol R.The Resistance is measured in ohms ( ). The circuit element used to model the current-
resisting behavior of a material is called the resistor.
12
Fig. 1.13 (a) Typical Resistor, (b) Circuit Symbol for Resistor
The resistance of a resistor depends on the material of which the conductor is made and geometrical
shape of the conductor. The resistance of a conductor is proportional to the its length ( and inversely
proportional to its cross sectional area (A). Therefore the resistance of a conductor can be written as,
The proportionality constant is called the specific resistance o resistivity of the conductor and its
value depends on the material of which the conductor is made.
The inverse of the resistance is called the conductance and inverse of resistivity is called specific
conductance or conductivity. The symbol used to represent the conductance is G and conductivity is .
Thus conductivity and its units are Siemens per meter
By using Ohm’s Law, The power dissipated in a resistor can be expressed in terms of R as below
Or
Example 1.8
In the circuit shown in Fig. below, calculate the current i, the conductance G, the power p and energy
lost in the resistor W in 2hours.
13
Solution:
The voltage across the resistor is the same as the source voltage (30 V) because the resistor and the
voltage source are connected to the same pair of terminals. Hence, the current is
The conductance is
or
or
1.5.2.2 INDUCTOR
A wire of certain length, when twisted into a coil becomes a basic inductor. The symbol for inductor
is shown in Fig.1.14 (b). If current is made to pass through an inductor, an electromagnetic field is
formed. A change in the magnitude of the current changes the electromagnetic field. Increase in
current expands the fields, and decrease in current reduces it. Therefore, a change in current produces
change in the electromagnetic field, which induces a voltage across the coil according to Faraday's
law of electromagnetic induction. i.e., the voltage across the inductor is directly proportional to the
time rate of change of current.
Mathematically,
Where L is the constant of proportionality called the inductance of an inductor. The unit of inductance
is Henry (H).we can rewrite the above equation as
14
From the above equation we note that the current in an inductor is dependent upon the integral of the
voltage across its terminal and the initial current in the coil .
The power absorbed by the inductor is
Example 1.9
Find the current through a 5-H inductor if the voltage across it is
The power
15
1.5.2.2 CAPACITOR
Fig. 1.15 (a) Typical Capacitor, (b) Capacitor connected to a voltage source, (c) Circuit Symbol of
capacitor
Any two conducting surfaces separated by an insulating medium exhibit the property of a capacitor.
The conducting surfaces are called electrodes, and the insulating medium is called dielectric. A
capacitor stores energy in the form of an electric field that is established by the opposite charges on
the two electrodes. The electric field is represented by lines of force between the positive and negative
charges, and is concentrated within the dielectric.
When a voltage source v is connected to the capacitor, as in Fig 1.15 (c), the source deposits a
positive charge q on one plate and a negative charge — q on the other. The capacitor is said to store
the electric charge. The amount of charge stored, represented by q, is directly pro-proportional to the
applied voltage v so that
Where C, the constant of proportionality, is known as the capacitance of the capacitor. The unit of
capacitance is the farad (F).
Although the capacitance C of a capacitor is the ratio of the charge q per plate to the applied voltage
v, it does not depend on q or v. It depends on the physical dimensions of the capacitor. For example,
for the parallel-plate capacitor shown in Fig.1.15 (a), the capacitance is given by
Where A is the surface area of each plate, d is the distance between the plates, and is the
permittivity of the dielectric material between the plates.
The current flowing through the capacitor is given by
16
From the above equation we note that the voltage across the terminals of a capacitor is dependent
upon the integral of the current through it and the initial voltage .
The power absorbed by the capacitor is
1. The current in a capacitor is zero if the voltage across it is constant; that means, the capacitor acts
as an open circuit to DC.
2. A small change in voltage across a capacitance within zero time gives an infinite current through
the capacitor, which is physically impossible. In a fixed capacitance the voltage cannot change
abruptly. i.e., A capacitor will oppose the sudden changes in voltages.
3. The capacitor can store a finite amount of energy, even if the current through it is zero.
4. A pure capacitor never dissipates energy, but only stores it; that is why it is called non-dissipative
passive element. However, physical capacitors dissipate power due to internal resistance.
Example 1.10
Determine the current through a 200 capacitor whose voltage is shown in Fig. below
Solution:
The voltage waveform can be described mathematically as
17
1.6 NETWORK/CIRCUIT TERMINOLOGY
In the following section various definitions and terminologies frequently used in electrical circuit
analysis are outlined.
Network Elements: The individual components such as a resistor, inductor, capacitor, diode,
voltage source, current source etc. that are used in circuit are known as network elements.
Network: The interconnection of network elements is called a network.
Circuit: A network with at least one closed path is called a circuit. So, all the circuits are
networks but all networks are not circuits.
Branch: A branch is an element of a network having only two terminals.
Node: A node is the point of connection between two or more branches. It is usually indicated by
a dot in a circuit.
Loop: A loop is any closed path in a circuit. A loop is a closed path formed by starting at a node,
passing through a set of nodes, and returning to the starting node without passing through any
node more than once.
Mesh or Independent Loop: Mesh is a loop which does not contain any other loops in it.
The most common and useful set of laws for solving electric circuits are the Kirchhoff’s voltage and
current laws. Several other useful relationships can be derived based on these laws. These laws are
formally known as Kirchhoff’s current law (KCL) and Kirchhoff’s voltage law (KVL).
This is also called as Kirchhoff's first law or Kirchhoff’s nodal law. Kirchhoff’s first law is based on
the law of conservation of charge, which requires that the algebraic sum of charges within a system
cannot change.
Statement: Algebraic sum of the currents meeting at any junction or node is zero. The term
'algebraic' means the value of the quantity along with its sign, positive or negative.
Where N is the number of branches connected to the node and is the nth current entering (or
leaving) the node. By this law, currents entering a node may be regarded as positive, while currents
leaving the node may be taken as negative or vice versa.
Alternate Statement: Sum of the currents flowing towards a junction is equal to the sum of the
currents flowing away from the junction.
18
Fig 1.16 Currents meeting in a junction
Consider Fig. 1.16 where five branches of a circuit are connected together at the junction or node A.
Currents I1, I2 and I4 are flowing towards the junction whereas currents I3 and I5 are flowing away
from junction A. If a positive sign is assigned to the currents I2 and I4 that are flowing into the
junction then the currents I3 and I4 flowing away from the junction should be assigned with the
opposite sign i.e. the negative sign.
Applying Kirchhoff’s current law to the junction A
I1 + I2 - I3 + I4 - I5= 0 (algebraic sum is zero)
The above equation can be modified as I1 + I2 + I4 = I3 + I5 (sum of currents towards the junction =
sum of currents flowing away from the junction).
This is also called as Kirchhoff's second law or Kirchhoff's loop or mesh law. Kirchhoff’s second law
is based on the principle of conservation of energy.
Statement: Algebraic sum of all the voltages around a closed path or closed loop at any instant is
zero. Algebraic sum of the voltages means the magnitude and direction of the voltages; care should be
taken in assigning proper signs or polarities for voltages in different sections of the circuit.
Where N is the number of voltages in the loop (or the number of branches in the loop) and is the nth
voltage in a loop.
The polarity of the voltages across active elements is fixed on its terminals. The polarity of the
voltage drop across the passive elements (Resistance in DC circuits) should be assigned with
reference to the direction of the current through the elements with the concept that the current flows
from a higher potential to lower potential. Hence, the entry point of the current through the passive
elements should be marked as the positive polarity of voltage drop across the element and the exit
point of the current as the negative polarity. The direction of currents in different branches of the
circuits is initially marked either with the known direction or assumed direction.
After assigning the polarities for the voltage drops across the different passive elements, algebraic
sum is accounted around a closed loop, either clockwise or anticlockwise, by assigning a particular
sign, say the positive sign for all rising potentials along the path of tracing and the negative sign for
all decreasing potentials. For example consider the circuit shown in Fig. 1.17
19
Fig. 1.17 Circuit for KVL
The circuit has three active elements with voltages E1, E2 and E3. The polarity of each of them is
fixed. R1, R2, R3 are three passive elements present in the circuit. Currents I1 and I3 are marked
flowing into the junction A and current I2 marked away from the junction A with known information
or assumed directions. With reference to the direction of these currents, the polarity of voltage drops
V1, V2 and V3 are marked.
For loop1 it is considered around clockwise
+ E1 - V1 + V3 - E3 = 0
+ E1 - I1 R1 + I3 R3 - E3 = 0
E1 - E3 = I1 R1 - I3 R3
For loop2 it is considered anticlockwise
+ E2+ V2+ V3 – E3 = 0
+ E2 + I2 R2 + I3 R3 – E3 = 0
E2 – E3 = - I2 R2 - I3 R3
Two equations are obtained following Kirchhoff’s voltage law. The third equation can be written
based on Kirchhoff’s current law as
I1 – I2 + I3 = 0
With the three equations, one can solve for the three currents I1, I2, and I3.
If the results obtained for I1, I2, and I3 are all positive, then the assumed direction of the currents are
said to be along the actual directions. A negative result for one or more currents will indicate that the
assumed direction of the respective current is opposite to the actual direction.
Example 1.11
Calculate the current supplied by two batteries in the circuit given below
20
Solution:
The four junctions are marked as A, B, C and D. The current through R1 is assumed to flow from A to
B and through R2, from C to B and finally through R3 from B to D. With reference to current
directions, polarities of the voltage drop in R1, R2 and R3 are then marked as shown in the figure.
Applying KCL to junction B
I3 =I1 + I2 …..(1)
Applying KVL to loop 1
E1 – I1R1 – I3R3 = 0
I1R1 + I3R3 = E1
10I1 + 25I3 = 90 …… (2)
Substituting Eq. (1) in Eq. (2)
10I1 + 25(I1 + I2) = 90
35I1 + 25I2 = 90 ……. (3)
Applying KVL to loop 2
E2 – I2R2 – I3R3 = 0
I2R2 + I3R3 = E2
5I2 + 25I3 = 125 …… (4)
21
………. (1)
If we apply KVL to the loop (moving in the clockwise direction), we have
……….. (2)
Combining equations (1) and (2), we get
……….. (3)
Or
……….. (4)
Equation (3) can be written as
………. (5)
implying that the two resistors can be replaced by an equivalent resistor ;that is
…………… (6)
Thus, Fig. 1.18 can be replaced by the equivalent circuit in Fig. 1.19. The two circuits in Fig 1.18 and
1.19 are the equivalent because they because they exhibit the same voltage-current relationships at the
terminals a-b. An equivalent circuit such as the one in Fig. 1.19 is useful in simplifying the analysis of
a circuit.
In general, the equivalent resistance of any number of resistors connected in series is the sum of the
individual resistances.
For N resistors in series then,
……… (7)
VOLTAGE DIVISION:
To determine the voltage across each resistor in Fig. 1.18, we substitute Eq. (4) into Eq. (1) and obtain
……… (8)
Notice that the source voltage is divided among the resistors in direct proportion to their
resistances; the larger the resistance, the larger the voltage drop. This is called the principle of voltage
division, and the circuit in Fig. 1.18 is called a voltage divider. In general, if a voltage divider has N
resistors ( ) in series with the source voltage , the nth resistor ( ) will have a voltage
drop of
.…….. (9)
Two or more resistors are said to be in parallel if the same voltage appears across each
element.Consider the circuit in Fig. 1.20, where two resistors are connected in parallel and therefore
have the same voltage across them.
22
23
Fig. 1.20 Two resistors in parallel
……… (1)
………. (2)
…….. (3)
Substituting Eq. (2) into Eq. (3), we get
……… (4)
where is the equivalent resistance of the resistors in parallel.
………. (5)
Or
……….. (6)
Thus,
The equivalent resistance of two parallel resistors is equal to the product of their resistances divided
by their sum.
It must be emphasized that this applies only to two resistors in parallel. From Eq. (6), if
We can extend the result in Eq. (5) to the general case of a circuit with N resistors in parallel. The
equivalent resistance is
24
……… (7)
Thus,
The equivalent Resistance of parallel-connected resistors is the reciprocal of the sum of the
reciprocals of the individual resistances.
Note that is always smaller than the resistance of the smallest resistor in the parallel combination.
Current Division:
Given the total current i entering node in Fig. 1.20, then how do we obtain currents ? We
know that the equivalent resistor has the same voltage, or
……. (8)
Substitute (8) in (2), we get
……….. (9)
This shows that the total current is shared by the resistors in inverse proportion to their resistances.
This is known as the principle of current division, and the circuit in Fig.1.20 is known as a current
divider. Notice that the larger current flows through the smaller resistance.
Fig. 1.22 (a) series connection of N inductors (b) Equivalent circuit for the series inductors
25
We know that the voltage across an inductor is
Where,
Thus
The equivalent inductance of series-connected inductors is the sum of the individual inductances.
* Inductors in series are combined in exactly the same way as resistors in series.
Fig. 1.23 (a) Parallel connection of N inductors (b) Equivalent circuit for parallel inductors
Using KCL,
If we neglect the initial value of current i.e, then current through inductor becomes
Hence,
26
Where,
Thus,
The equivalent inductance of parallel inductors is the reciprocal of the sum of the reciprocals of the
individual inductances.
* Note that the inductors in parallel are combined in the same way as resistors in parallel.
Fig. 1.24 (a) series connection of N capacitors (b) Equivalent circuit for the series capacitors
If we neglect the initial value of voltage i.e, then voltage across the capacitor becomes
27
Where,
Thus,
The equivalent capacitance of series-connected capacitors is the reciprocal of the sum of the
reciprocals of the individual capacitances.
* Note that the capacitors in series are combined in the same way as resistors in parallel.
For N=2,
Fig. 1.25 (a) Parallel connection of N capacitors (b) Equivalent circuit for parallel capacitors
28
Where,
Thus
The equivalent capacitance of parallel-connected capacitors is the sum of the individual capacitances.
* Capacitors in parallel are combined in exactly the same way as resistors in series.
The measurement of a given quantity is the result of comparison between the quantity to be measured
and a definite standard. The instruments which are used for such measurements are called measuring
instruments. The three basic quantities in the electrical measurement are current, voltage and power.
The measurement of these quantities is important as it is used for obtaining measurement of some
other quantity or used to test the performance of some electronic circuits or components etc.
1. With the introduction of the instrument in the circuit, the circuit conditions should not be
altered. Thus the quantity to be measured should not get affected due to the instrument used.
2. The power consumed by the instruments for their operation should be as small as
possible.
The instrument which measures the current flowing in the circuit is called ammeter while the
instrument which measures the voltage across any two points of a circuit is called voltmeter. But there
is no fundamental difference in the operating principle of analog voltmeter and ammeter. The action
of almost all the analog ammeters and voltmeters depends on the deflecting torque produced by an
electric current. In ammeters such a torque is proportional to the current to be measured. In voltmeters
this torque is decided by a current which is proportional to the voltage to be measured. Thus all the
analog ammeters and voltmeters are basically current measuring devices. The instruments which are
used to measure the power are called power meters or wattmeters.
1) Absolute instruments
Absolute instruments are those which give the value of the quantity to be measured in terms of the
constants of the instrument and their detection only. No previous calibration or comparison is
necessary in their case. The example of such an instrument is tangent galvanometer, which gives the
value of current, in terms of the tangent of deflection produced by the current, the radius and number
of turns of wire used and the horizontal component of earth's field.
2) Secondary instruments
Secondary instruments are those, in which the value of electrical quantity to be measured can be
determined from the deflection of the instruments, only when they have been pre-calibrated by
comparison with an absolute instrument. Without calibration, the deflection of such instruments is
29
meaningless. Secondary instruments are most generally used in everyday work; the use of the
absolute instruments being merely confined within laboratories, as standardizing instruments.
The secondary instruments are again divided into the following three types
a) Indicating instruments
b) Recording instruments
c) Integrating instruments
a) Indicating instruments:
Indicating instruments are those which indicate the instantaneous value of the electrical quantity being
measured at the time at which it is being measured. Their indications are given by pointers moving
over calibrated dials. Ordinary ammeters, voltmeters and wattmeters belong to this class.
b) Recording instruments:
These instruments give a continuous record of the given electrical quantity which is being measured
over a specific period. The examples are various types of recorders. In such recording instruments, the
readings are recorded by drawing the graph. The pointer of such instruments is provided with a
marker i.e. pen or pencil, which moves on graph paper as per the reading. The X-Y plotter is the best
example of such an instrument.
c) Integrating instruments:
These instruments measure the total quantity of electricity delivered over period of time. For example
a household energy meter registers number of revolutions made by the disc to give the total energy
delivered, with the help of counting mechanism consisting of dials and pointers.
In case of measuring instruments, the effect of unknown quantity is converted into a mechanical force
which is transmitted to the pointer which moves over a calibrated scale. The moving system of such
instrument is mounted on a pivoted spindle. For satisfactory operation of any indicating instrument,
following systems must be present in an instrument.
In most of the indicating instruments the mechanical force proportional to the quantity to be measured
is generated. This force or torque deflects the pointer. The system which produces such a deflecting
torque is called deflecting system and the torque is denoted as Td.
The deflecting system uses one of the following effects produced by current or voltage, to
produce deflecting torque.
a) Magnetic Effect: When a current carrying conductor is placed in uniform magnetic field, it
experiences a force which causes to move it. This effect is mostly used in many instruments like
moving iron attraction and repulsion type, permanent magnet moving coil instruments etc
b) Thermal Effect: The current to be measured is passed through a small element which heats it to
cause rise in temperature which is converted to an e.m.f. by a thermocouple attached to it.
When two dissimilar metals are connected end to end to form a closed loop and the two junctions
formed are maintained at different temperatures, then e.m.f. is induced which causes the flow of
current through the closed circuit which is called a thermocouple.
30
c) Electrostatic Effect: When two plates are charged, there is a force exerted between them, which
move one of the plates. This effect is used in electrostatic instruments which are normally
voltmeters.
d) Induction Effect: When a non-magnetic conducting disc is placed in a magnetic field produced
by electromagnets which are excited by alternating currents, an e.m.f. is induced in it.
If a closed path is provided, there is a flow of current in the disc. The interaction between induced
currents and the alternating magnetic fields exerts a force on the disc which causes to move it.
This interaction is called an induction effect. This principle is mainly used in energy meters.
e) Hall Effect: If a bar of semiconducting material is placed in uniform magnetic field and if the bar
carries current, then an e.m.f. is produced between two edges of conductor. The magnitude of this
e.m.f. depends on flux density of magnetic field, current passing through the conducting bar and
Hall Effect co-efficient which is constant for a given semiconductor. This effect is mainly used in
flux-meters.
Thus the deflecting system provides the deflecting torque or operating torque for movement of pointer
from its zero position. It acts as the prime mover for the deflection of pointer.
This system should provide a force so that current or any other electrical quantity will produce
deflection of the pointer proportional to its magnitude. The important functions of this system are,
1) It produces a force equal and opposite to the deflecting force in order to make the deflection of
pointer at a definite magnitude. If this system is absent, then the pointer will swing beyond its final
steady position for the given magnitude and deflection will become indefinite.
2) It brings the moving system back to zero position when the force which causes the movement of
the moving system is removed. It will never come back to its zero position in the absence of
controlling system.
The controlling torque in indicating instruments may be provide by one of the following two
methods.
1) GRAVITY CONTROL
31
This type of control consists of a small weight attached to the moving system whose position is
adjustable. This weight produces a controlling torque due to gravity. This weight is called control
weight. The Figs. 1.29(a) shows the gravity control system. At the zero position of the pointer, the
controlling torque is zero. This position is shown as position A of the weight in the Fig. 1.29(b). If the
system deflects, the weight position also changes, as shown in the Fig.1.29(b).
The system deflects through an angle . The control weight acts at a distance from the center.
The component W sin of this weight we try to restore the pointer back to the zero position.
Thus,
Here
Generally all meters are current sensing meters, where deflecting torque is proportional to
current. i.e.,
Where K= constant
In equilibrium position,
function of, the scale for the instrument using gravity control is not uniform.
Advantages:
3) The controlling torque can be varied by adjusting the position of the control weight.
2) The system must be used in vertical position only and must be properly levelled.
Otherwise it may cause serious errors in the measurement.
3) As delicate and proper leveling required, in general it is not used for indicating
instruments and portable instruments.
32
2) SPRING CONTROL
Two hair springs are attached to the moving system which exerts controlling torque. To
employ spring control to an instrument, following requirements are essential.
The arrangement of the springs is shown in the Fig. 1.30. The springs are made up of non-magnetic
materials like silicon bronze, hard rolled silver or copper, platinum silver and german silver. For most
of the instruments, phosphor bronze spiral springs are provided. Flat spiral springs are used in almost
all indicating instruments. The inner end of the spring is attached to the spindle while the outer end is
attached to a lever or arm which is actuated by a set of screw mounted at the front of the instrument.
So zero setting can be easily done.
The controlling torque provided by the instrument is directly proportional to the angular deflection of
the pointer.
At equilibrium
33
Thus the deflection is proportional to the current. Hence the scale of the instrument using spring
control is uniform. When the current is removed, due to spring force the pointer comes back to initial
position. The spring control is very popular and is used in almost all indicating instruments.
The deflecting torque provides some deflection and controlling torque acts in the opposite direction to
that of deflecting torque. So before coming to the rest, pointer always oscillates due to inertia, about
the equilibrium position. Unless pointer rests, final reading cannot be obtained. So to bring the pointer
to rest within short time, damping system is required. The system should provide a damping torque
only when the moving system is in motion. Damping torque is proportional to velocity of the moving
system but it does not depend on operating current. It must not affect controlling torque or increase
the friction.
The quickness with which over damped the moving system settles to the final steady position Time
depends on relative damping. If the moving system reaches to its final position rapidly.
but smoothly without oscillations, the instrument is said to be critically damped. If the instrument is
under damped, the moving system will oscillate about the final steady position with decreasing
amplitude and will take some timeto come to rest. The instrument is said to be over damped, if the
moving system moves slowly to its final steady position. In over damped case the response of the
system is very slow and sluggish. In practice slightly under damped systems are preferred. The time
response of damping system for various types of damping conditions is shown in the Fig. 1.31.
34
1) AIR FRICTION DAMPING
This arrangement consists of a light aluminium piston which is attached to the moving system, as
shown in the Fig. 1.32.
The piston moves in a fixed air chamber. It is close to one end. The clearance between piston and wall
chambers is uniform and small. The piston reciprocates in the chamber when there are oscillations.
When piston moves into the chamber, air inside is compressed and pressure of air developed due to
friction opposes the motion of pointer. There is also opposition to motion of moving system when
piston moves out of the chamber. Thus the oscillations and the overshoot gets reduced due to and fro
motion of the piston in the chamber, providing necessary damping torque. This helps in settling down
the pointer to its final steady position very quickly.
The arrangement is shown in the Fig. 1.33. It consists of a vane attached to the spindle which is
completely dipped in the oil. The frictional force between oil and the vane is used to disc produce the
damping torque, which opposes the oscillating behavior of the pointer.
35
Advantages:
1. This can be only used for the instruments which are in vertical "position.
2. Due to oil leakage, the instruments cannot be kept clean.
This is the most effective way of providing damping. It is based on the Faraday's law and Lenz's law.
When a conductor moves in a magnetic field cutting the flux, e.m.f. gets induced in it and the
direction of this e.m.f. is so as to oppose the cause producing it.
In this method, an 'aluminium disc is connected to the spindle. The arrangement of disc is
such that when it rotates, it cuts the magnetic flux lines of a permanent magnet. The arrangement is
shown in the Fig. 1.34. When the pointer oscillates, aluminium disc rotates under the influence of
magnetic field of damping magnet. So disc cuts the flux which causes an induced e.m.f. in the disc.
The disc is a closed \path hence induced e.m.f. circulates current through the disc called eddy current.
The direction of such eddy current is so as oppose the cause producing it. The cause is relative motion
between disc and field. Thus it produces an opposing torque so as to reduce the oscillations of pointer.
This brings pointer to rest quickly. This is most effective and efficient method of damping.
Principe:
When a current carrying coil is placed in the magnetic field produced by permanent magnet, the coil
experiences a force and moves. The amount of force experienced by the coil is proportional to the
current passing through the coil.
36
Construction:
The construction of PMMC instrument is as shown in the Fig. 1.35. It consists of a moving coil which
is either rectangular or circular in shape. It has number of turns of fine wire. The coil is suspended so
that it is free to turn about its vertical axis. The coil is placed in uniform, horizontal and radial
magnetic field of a permanent magnet in the shape of a horse-shoe. As the coil is moving and the
magnet is permanent, the instrument is called permanent magnet moving coil instrument. The
controlling torque is provided by two phosphor bronze hair springs. The damping torque is provided
by eddy current damping. It is obtained by movement of the aluminium former, moving in the
magnetic field of the permanent magnet.The pointer is carried by the spindle and it moves over a
graduated scale. The pointer has light weight so that it can deflect rapidly. The mirror is placed below
the pointer to get the accurate reading by removing the parallax error. The scale markings of the basic
PMMC instruments are usually linearly spaced as the deflecting torque and hence the pointer
deflection is directly proportional to the current passing through the coil.
Operation:
Whenever the PMMCinstrument is connected in the electric circuit to measure the current or voltage,
current flows through the moving coil. As the current carrying coil is placed in the magnetic field
produced by the permanent magnet, a mechanical force acts on the coil. As the coil is attached to the
moving systemthe pointer moves in a clockwise direction over a graduated scale to indicate the value
of current or voltage being measured. Therefore, the mechanical force is responsible for producing the
deflecting torque in the clockwise direction. The two hair springs provided in the spindle will generate
the necessary controlling torque. When the controlling torque equals to the deflecting torque the
pointer comes to the rest and indicate the current through the coil. The damping torque is provided by
the eddy current damping, it is obtained by the movement of the aluminium former moving in the
magnetic field of permanent magnet.
If we reverse the direction of current through the coil, then the pointer tends to rotate in anti
clockwise direction. But a stopper or observer is provided to protect the pointer tends to rotate in the
anticlockwise direction. The resultant deflecting torque in the coil for AC input current is zero. Hence
the PMMC meter cannot measure AC quantities and measure DC only.
When the current of I ampere flows through the coil, the coil experiences a force of F Newton which
is given by
F = NBIl newton
Deflecting torque
37
= NBIl*d
= NBIA
Td α I
Td = K I
Tc α θ
Tc = Kc θ
Td = Tc
K I = Kc θ
θ = (K/Kc) I
Therefore,
θαI
Thus the deflection of the pointer is directly proportional to the current passing through the coil.
Advantages:
1. The scale is uniformly divided as the current is directly proportional to deflection of the
pointer. Hence it is very easy to measure the quantities from the instruments.
2. Power consumption is also very low.
3. The torque to weight ratio is high
4. The sensitivity is high
5. Extension of instrument range is possible
6. The eddy currents induced in the metallic former on which coil is wound, provide
effective damping.
Disadvantages:
38
2. The cost is high due to delicate construction and accurate machining.
3. Ageing of permanent magnet and control springs introduces the errors.
The basic sources of errors in PMMC instruments are friction, temperature and aging of various parts.
To reduce the frictional errors ratio of torque to weight is made very high.
The most serious errors are produced by the heat generated or by changes in the temperature. This
changes the resistance of the working coil, causing large errors. In case of voltmeters, a large series
resistance of very low temperature coefficient is used. This reduces the temperature errors.
The aging of permanent magnet and control springs also cause errors. The weakening of magnet and
springs cause opposite errors. The weakening of magnet cause less deflection while weakening of the
control springs cause large deflection, for a particular value of current. The proper use of material and
pre-ageing during manufacturing can reduce the errors due to weakening of the control springs.
The basic working principle of these instruments is very simple that a soft iron piece if brought near
the magnet gels attracted by the magnet.
Construction:
The construction of the attraction type instrument is shown in the Fig. 1.36. It consists of a fixed coil
C and moving iron piece D. The coil is flat and has a narrow slot like opening. The moving iron is a
flat disc which is eccentrically mounted on the spindle. The spindle is supported between the jewel
bearings. The spindle carries a pointer which moves over a graduated scale. The numbers of turns of
the fixed coil are dependent on the range of the instrument. For passing large current through the coil
only few turns are required
39
The controlling torque is provided by the springs but gravity control may also be used for vertically
mounted panel type instruments. The damping torque is provided by the air friction. A light
aluminium piston is attached to the moving system. It moves in a fixed chamber. The chamber is
closed at one end. It can also be provided with the help of vane attached to the moving system. The
operating magnetic field in moving iron instruments is very weak. Hence eddy current damping is not
used since it requires a permanent magnet which would affect or distort the operating field.
Operation:
When the instrument is connected in a circuit to measure the current, then the fixed coil develops a
magnetic field. The coil behaves like a magnet and attracts the moving iron piece towards it. As an
moving iron piece is attached to the moving system, the pointer moves over a graduated scale.
If the current in the coil is reversed, direction of magnetic field produced is also reverse
and attracts the iron piece toward the centre of the coil and the pointer moves. Hence the moving iron
instrument can be used o measure both DC and AC quantities.
Principle:
Two iron pieces are kept with close proximity in a magnetic field get magnetized with the same
polarity. Hence a repulsive force is developed. If one of the two iron pieces is made movable, the
repulsive force will act on it and move it one side. This movement is used measure voltage or current
which produces the field.
Construction:
The construction of the attraction type instrument is shown in the Fig. 1.37. It consists of a fixed hallow
cylindrical coil which carries the operating current. Two iron pieces (iron vanes) are available inside
the coil, one iron piece is fixed and the other is movable. The fixed iron piece is attached to the coil,
40
while the moving iron piece is attached to the moving system. When the moving iron is replulsed
from the fixed iron piece the pointer moves over a graduated scale.
Operation:
When the voltage is applied to the coil the magnetic field will be developed inside the coil. Then the
two iron pieces are magnetized with same polarity. Due to the same polarity in between them, the
moving iron piece get repulsive from the fixed iron piece. As the pointer is attached to the moving
iron, with the movement of the moving iron the pointer also moves and show the reading. Here the
controlling torque is provided by the spring control or gravity control and damping torque is provided
by the air friction damping.
Then the deflection torque produced due to the current flowing through the coil is given by,
= angular deflection dL
=change in inductance
d = change in angular deflection
Hence, the deflection of the moving iron instrument is directly proportional to the square of the
current flowing through the coil.
Advantages:
1) Hysteresis error: Due to hysteresis effect, the flux density for the same current while ascending
and descending values is different. While descending, the flux density is higher and while ascending it
is lesser. So meter reads higher for descending values of current or voltage. So remedy for this is to
use smaller iron parts which can demagnetize quickly or to work with lower flux densities
41
2) Temperature error: The temperature error arises due to the effect of temperature on the
temperature coefficient of the spring. This error is of the order of 0.02% per °C change in
temperature. Errors can cause due to self heating of the coil and due to which change in resistance of
the coil. So coil and series resistance must have low temperature coefficient. Hence manganin is
generally used for the series resistances.
3) Stray magnetic field error: The operating magnetic field in case of moving iron instruments is
very low. Hence effect of external i.e. stray magnetic field can cause error. This effect depends on the
direction of the stray magnetic field with respect to the operating field of the instrument.
4) Frequency error: These are related to a.c. operation of the instrument. The change in frequency
affects the reactance of the working coil and also affects the magnitude of the eddy currents. This
causes errors in the instrument.
5) Eddy current error: When instrument is used for a.c. measurements the eddy currents are
produced in the iron parts of the instrument. The eddy current affects the instrument current causing
the change in the deflecting torque. This produces the error in the meter reading. As eddy currents are
frequency dependent, frequency changes cause eddy current error.
UNIT II
DC MACHINES
2.1 Introduction
42
Converters that are used to continuously translate electrical input to mechanical output or vice
versa are called electric machines. The process of translation is known as electromechanical energy
conversion. An electric machine is therefore a link between an electrical system and a mechanical
system. In these machines the conversion is reversible. If the conversion is from mechanical to
electrical energy, the machine is said to act as a generator. If the conversion is from electrical to
mechanical energy, the machine is said to act as a motor. In these machines, conversion of energy
from electrical to mechanical form or vice versa results from the following two electromagnetic
phenomena:
A DC generator can be used as a DC motor without any constructional changes and vice versa is
also possible. Thus, a DC generator or a DC motor can be broadly termed as a DC machine. These
basic constructional details are also valid for the construction of a DC motor. Hence, let's call this
point asconstruction of a DC machine instead of just 'construction of a dc generator'.
The above figure shows the constructional details of a simple 4-pole DC machine. A DC machine
consists of two basic parts; stator and rotor. Basic constructional parts of a DC machine are described
below.
43
1. Yoke: The outer frame of a dc machine is called as yoke. It is made up of cast iron or steel. It not
only provides mechanical strength to the whole assembly but also carries the magnetic flux
produced by the field winding.
2. Poles and pole shoes: Poles are joined to the yoke with the help of bolts or welding. They carry
field winding and pole shoes are fastened to them. Pole shoes serve two purposes; (i) they support
field coils and (ii) spread out the flux in air gap uniformly.
3. Field winding: They are usually made of copper. Field coils are former wound and placed on
each pole and are connected in series. They are wound in such a way that, when energized, they
form alternate North and South poles.
4. Armature core: Armature core is the rotor of the machine. It is cylindrical in shape with slots to
carry armature winding. The armature is built up of thin laminated circular steel disks for
reducing eddy current losses. It may be provided with air ducts for the axial air flow for cooling
purposes. Armature is keyed to the shaft.
5. Armature winding: It is usually a former wound copper coil which rests in armature slots. The
armature conductors are insulated from each other and also from the armature core. Armature
winding can be wound by one of the two methods; lap winding or wave winding. Double layer
lap or wave windings are generally used. A double layer winding means that each armature slot
will carry two different coils.
6. Commutator and brushes: Physical connection to the armature winding is made through a
commutator-brush arrangement. The function of a commutator, in a dc generator, is to collect the
current generated in armature conductors. Whereas, in case of a dc motor, commutator helps in
providing current to the armature conductors. A commutator consists of a set of copper segments
which are insulated from each other. The number of segments is equal to the number of armature
coils. Each segment is connected to an armature coil and the commutator is keyed to the shaft.
Brushes are usually made from carbon or graphite. They rest on commutator segments and slide
on the segments when the commutator rotates keeping the physical contact to collect or supply the
current
44
Figure 2.3 Commutator2.3 Classifications of DC
Machines: (DC Motors and DC Generators)
Each DC machine can act as a generator or a motor. Hence, this classification is valid forboth: DC
generators and DC motors. DC machines are usually classified on the basis oftheir field excitation
method. This makes two broad categories of dc machines; (i) Separately excited and (ii) Self-excited.
Separately excited: In separately excited dc machines, the field winding is supplied from a
separate power source. That means the field winding is electrically separated from the armature
circuit. Separately excited DC generators are not commonly used because they are relatively
expensive due to the requirement of an additional power source or circuitry. They are used in
laboratories for research work, for accurate speed control of DC motors with Ward-Leonard
system and in few other applications where self-excited DC generators are unsatisfactory. In
this type, the stator field flux may also be provided with the help of permanent magnets (such
as in the case of a permanent magnet DC motors). A PMDC motor may be used in a small toy
car.
Self-excited: In this type, field winding and armature winding are interconnected in various
ways to achieve a wide range of performance characteristics (for example, field winding in
series or parallel with the armature winding). In self-excited type of DC generator, the field
winding is energized by the current produced by themselves. A small amount of flux is always
present in the poles due to the residual magnetism. So, initially, current induces in the armature
conductors of a dc generator only due to the residual magnetism. The field flux gradually
increases as the induced current starts flowing through the field winding.
▪ Series wound – In this type, field winding is connected in series with the armature
winding. Therefore, the field winding carries whole load current (armature
current). That is why series winding is designed with few turns of
thick wire and the resistance is kept very low (about 0.5 Ohm).
▪ Shunt wound – Here, field winding is connected in parallel with the armature
winding. Hence, the full voltage is applied across the field winding. Shunt winding is
made with a large number of turns and the resistance is kept very high (about 100
Ohm). It takes only small current which is less than 5% of the
rated armature current.
▪ Compound wound – In this type, there are two sets of field winding. One is
connected in series and the other is connected in parallel with the
armature winding. Compound wound machines are further divided as -
▪ Short shunt – field winding is connected in parallel with only the
armature winding
45
▪ Long shunt – field winding is connected in parallel with the
combination of series field winding and armature winding
DC GENERATOR
46
According to Fleming’s right hand rule, the direction of induced current changes whenever the
direction of motion of the conductor changes. Let’s consider an armature rotating clockwise and a
conductor at the left is moving upward. When the armature completes a half rotation, the direction of
motion of that particular conductor will be reversed to downward. Hence, the direction of current in
every armature conductor will be alternating. If you look at the above figure, you will know how the
direction of the induced current is alternating in an armature conductor. But with a split ring
commutator, connections of the armature.
conductors also gets reversed when the current reversal occurs. And therefore, we get
unidirectional current at the terminals.
Now,
▪ Average emf generated per conductor is given by dΦ/dt (Volts) ... eq. 1 ▪ Flux
cut by one conductor in one revolution = dΦ = PΦ ….(Weber),
▪ Number of revolutions per second (speed in RPS) = N/60 ▪
Therefore, time for one revolution = dt = 60/N (Seconds)
▪ From eq. 1, emf generated per conductor = dΦ/dt = PΦN/60 (Volts) …..(eq. 2)
Above equation-2 gives the emf generated in one conductor of the generator. The
conductors are connected in series per parallel path, and the emf across the generator
terminals is equal to the generated emf across any parallel path.
For simplex lap winding, number of parallel paths is equal to the number of poles (i.e. A=P),
Therefore, for simplex lap wound dc generator, Eg = PΦNZ / 60P
For simplex wave winding, number of parallel paths is equal to 2 (i.e P=2),
Therefore, for simplex wave wound dc generator, Eg = PΦNZ / 120
DC generators can be classified in two main categories, viz; (i) Separately excited and (ii) Self-
excited.
(i) Separately excited: In this type, field coils are energized from an independent external DC
source.
(ii) Selfexcited: In this type, field coils are energized from the current produced by the generator
itself. Initial emf generation is due to residual magnetism in field poles. The generated emf causes a
part of current to flow in the field coils, thus strengthening the field flux and thereby increasing emf
generation. Self excited dc generators can further be divided into three types
2.7 Characteristics of DC Generators
47
Generally, following three characteristics of DC generators are taken into considerations: (i) Open
Circuit Characteristic (O.C.C.), (ii) Internal or Total Characteristic and (iii) External Characteristic.
These characteristics of DC generators are explained below.
Now, from the emf equation of dc generator, we know that Eg = kɸ. Hence, the generated emf should
be directly proportional to field flux (and hence, also directly proportional to the field current).
However, even when the field current is zero, some amount of emf is generated (represented by OA in
the figure below). This initially induced emf is due to the fact that there exists some residual
magnetism in the field poles. Due to the residual magnetism, a small initial emf is induced in the
armature. This initially induced emf aids the existing residual flux, and hence, increasing the overall
field flux. This consequently increases the induced emf. Thus, O.C.C. follows a straight line.
However, as the flux density increases, the
poles get saturated and the ɸ becomes practically constant. Thus, even we increase the If further, ɸ
remains constant and hence, Eg also remains constant. Hence, the O.C.C. curve looks like the B-H
characteristic.
48
The above figure shows a typical no-load saturation curve or open circuit characteristics for all
types of DC generators.
An internal characteristic curve shows the relation between the on-load generated emf (Eg) and the
armature current (Ia). The on-load generated emf Eg is always less than E0 due to the armature
reaction. Eg can be determined by subtracting the drop due to demagnetizing effect of armature
reaction from no-load voltage E0. Therefore, internal characteristic curve lies below the O.C.C.
curve.
An external characteristic curve shows the relation between terminal voltage (V) and the load current
(IL). Terminal voltage V is less than the generated emf Eg due to voltage drop in the armature circuit.
Therefore, external characteristic curve lies below the internal characteristic curve. External
characteristics are very important to determine the suitability of a generator for a given purpose.
Therefore, this type of characteristic is sometimes also called as performance characteristic or load
characteristic.
Internal and external characteristic curves are shown below for each type of generator.
If there is no armature reaction and armature voltage drop, the voltage will remain constant for any
load current. Thus, the straight line AB in above figure represents the no-load voltage vs. load current
IL. Due to the demagnetizing effect of armature reaction, the on-load generated emf is less than the
no-load voltage. The curve AC represents the on-load generated emf Eg vs. load current IL i.e.
internal characteristic (as Ia = IL for a separately excited dc generator). Also, the terminal voltage is
lesser due to ohmic drop occurring in the armature and brushes. The curve AD represents the
terminal voltage vs. load current i.e. external characteristic.
To determine the internal and external load characteristics of a DC shunt generator the machine is
allowed to build up its voltage before applying any external load. To build up voltage of a shunt
generator, the generator is driven at the rated speed by a prime mover. Initial voltage is induced due
to residual magnetism in the field poles. The generator builds up its voltage as explained by the
49
O.C.C. curve. When the generator has built up the voltage, it is gradually loaded with resistive load
and readings are taken at suitable intervals. Connection arrangement is as shown in the figure below.
Unlike, separately excited DC generator, here, IL≠Ia. For a shunt generator, Ia=IL+If. Hence, the
internal characteristic can be easily transmitted to Eg vs. IL by subtracting the correct value of If
from Ia. During a normal running condition, when load resistance is decreased, the load current
increases. But, as we go on decreasing the load resistance, terminal voltage also falls. So, load
resistance can be decreased up to a certain limit, after which the terminal voltage drastically
decreases due to excessive armature reaction at very high armature current and increased I2R
losses. Hence, beyond this limit any further decrease in load resistance results in decreasing load
current. Consequently, the external characteristic curve turns back as shown by dotted line in the
above figure.
The curve AB in above figure identical to open circuit characteristic (O.C.C.) curve. This is because
in DC series generators field winding is connected in series with armature and load. Hence, here
load current is similar to field current (i.e. IL=If). The curve OC and OD
50
2.7.4 Characteristics of DC Compound Generator
The above figure shows the external characteristics of DC compound generators. If series winding
amp-turns are adjusted so that, increase in load current causes increase in terminal voltage then the
generator is called to be over compounded. The external characteristic for over compounded generator
is shown by the curve AB in above figure.
If series winding amp-turns are adjusted so that, the terminal voltage remains constant even the load
current is increased, then the generator is called to be flat compounded. The external characteristic
for a flat compounded generator is shown by the curve AC.
If the series winding has lesser number of turns than that would be required to be flat compounded,
then the generator is called to be under compounded. The external characteristics for an under
compounded generator are shown by the curve AD.
DC MOTOR
A motor is an electrical machine which converts electrical energy into mechanical energy. The
principle of working of a DC motor is that "whenever a current carrying conductor is placed in a
magnetic field, it experiences a mechanical force". The direction of this force is given by
Fleming's left hand rule and it's magnitude is given by F = BIL. Where, B = magnetic flux density,
I = current and L = length of the conductor within the magnetic field.
Fleming's left hand rule: If we stretch the first finger, second finger and thumb of our left hand to
be perpendicular to each other AND direction of magnetic field is represented by the first finger,
51
direction of the current is represented by second finger then the thumb represents the direction of the
Working of DC Motor
When armature windingsare connected to a DC supply, current sets up in the winding. Magnetic field
may be provided by field winding (electromagnetism) or by using permanent magnets. In this case,
current carrying armature conductors experience force due to the magnetic field, according to the
principle stated above.
Commutator is made segmented to achieve unidirectional torque. Otherwise, the direction of force
would have reversed every time when the direction of movement of conductor is reversed the
magnetic field.
Back EMF
According to fundamental laws of nature, no energy conversion is possible until there is something to
oppose the conversion. In case of generators this opposition is provided by magnetic drag, but in case
of dc motors there is back emf.
When the armature of the motor is rotating, the conductors are also cutting the magnetic flux lines and
hence according to the Faraday's law of electromagnetic induction, an emf induces in the armature
conductors. The direction of this induced emf is such that it opposes the armature current (Ia) . The
circuit diagram below illustrates the direction of the back emf and armature current. Magnitude of
Back emf can be given by the emf equation of DC generator.
52
Magnitude of back emf is directly proportional to speed of the motor. Consider the load on a dc motor
is suddenly reduced. In this case, required torque will be small as compared to the current torque.
Speed of the motor will start increasing due to the excess torque. Hence, being proportional to the
speed, magnitude of the back emf will also increase. With increasing back emf armature current will
start decreasing. Torque being proportional to the armature current, it will also decrease until it
becomes sufficient for the load. Thus, speed of the motor will regulate.
On the other hand, if a dc motor is suddenly loaded, the load will cause decrease in the speed. Due to
decrease in speed, back emf will also decrease allowing more armature current. Increased armature
current will increase the torque to satisfy the load requirement. Hence, presence of the back emf
makes a dc motor ‘self-regulating’.
DC motors are usually classified of the basis of their excitation configuration, as follows - ▪
Separately excited (field winding is fed by external source)
▪
Self excited -
Series wound (field winding is connected in series with the armature)
Shunt wound (field winding is connected in parallel with the armature)
Compound wound -
Long shunt
Short shunt
When armature conductors of a DC motor carry current in the presence of stator field flux, a
mechanical torque is developed between the armature and the stator. Torque is given by the product
of the force and the radius at which this force acts.
▪ Net power developed in the armature = word done / time
But, F × r = T and 2πN/60 = angular velocity ω in radians per second. Putting these in the
above equation 2.1
▪ The power developed in the armature can be given as, Pa = Ta × ω = Ta × 2πN/60
53
▪ The mechanical power developed in the armature is converted from the electrical
power,
▪ We know, Eb = PΦNZ / 60A
▪ Therefore, Ta × 2πN/60 = (PΦNZ / 60A) × Ia
The term (PZ / 2πA) is practically constant for a DC machine. Thus, armature torque is
directly proportional to the product of the flux and the armature current i.e. Ta Φ.Ia
Due to iron and friction losses in a dc machine, the total developed armature torque is not available at
the shaft of the machine. Some torque is lost, and therefore, shaft torque is always less than the
armature torque.
Generally, three characteristic curves are considered important for DC motors which are, (i) Torque
vs. armature current, (ii) Speed vs. armature current and (iii) Speed vs. torque. These are explained
below for each type of DC motor. These characteristics are determined by keeping the following two
relations in mind.
Ta α ɸ.Ia and
N α Eb/ɸ
These above equations can be studied at - emf and torque equation of dc machine. For a DC motor,
magnitude of the back emf is given by the same emf equation of a dc generator i.e. Eb = PɸNZ / 60A.
For a machine, P, Z and A are constant, therefore, N Eb/ɸ
This characteristic is also known as electrical characteristic. We know that torque is directly
proportional to the product of armature current and field flux, Ta ɸ.Ia. In DC series motors, field
winding is connected in series with the armature, i.e. Ia = If. Therefore, before magnetic saturation of
the field, flux ɸ is directly proportional to Ia. Hence, before magnetic saturation Ta α Ia 2. Therefore,
the Ta-Ia curve is parabola for smaller values of Ia.
After magnetic saturation of the field poles, flux ɸ is independent of armature current Ia. Therefore,
the torque varies proportionally to Ia only, T Ia.Therefore, after magnetic saturation, Ta-Ia curve
becomes a straight line.
54
The shaft torque (Tsh) is less than armature torque (Ta) due to stray losses. Hence, the curve Tsh vs Ia
lies slightly lower.
In DC series motors, (prior to magnetic saturation) torque increases as the square of armature current,
these motors are used where high starting torque is required.
For small load current (and hence for small armature current) change in back emf Eb is small and it
may be neglected. Hence, for small currents speed is inversely proportional to ɸ. As we know, flux is
directly proportional to Ia, speed is inversely proportional to Ia. Therefore, when armature current is
very small the speed becomes dangerously high. That is why a series motor should never be started
without some mechanical load.
But, at heavy loads, armature current Ia is large. And hence, speed is low which results in
decreased back emf Eb. Due to decreased Eb, more armature current is allowed.
This characteristic is also called as mechanical characteristic. From the above two characteristics
of DC series motor, it can be found that when speed is high, torque is low and vice versa
In case of DC shunt motors, we can assume the field flux ɸ to be constant. Though at heavy loads, ɸ
decreases in a small amount due to increased armature reaction. As we are neglecting the change in
the flux ɸ, we can say that torque is proportional to armature current. Hence, the Ta-Ia characteristic
for a dc shunt motor will be a straight line through the origin. Since heavy starting load needs heavy
starting current, shunt motor should never be started on a heavy load.
As flux ɸ is assumed to be constant, we can say N Eb. But, as back emf is also almost constant, the
speed should remain constant. But practically, ɸ as well as Eb decreases with increase in load. Back
emf Eb decreases slightly more than ɸ, therefore, the speed decreases slightly. Generally, the speed
decreases only by 5 to 15% of full load speed. Therefore, a shunt motor can be assumed as a
constant speed motor. In speed vs. armature current characteristic in the following figure, the
straight horizontal line represents the ideal characteristic and the actual characteristic is shown by the
dotted line.
55
2.11.3 Characteristics of DC Compound Motor
DC compound motors have both series as well as shunt winding. In a compound motor, if series and
shunt windings are connected such that series flux is in direction as that of the shunt flux then the
motor is said to be cumulatively compounded. And if the series flux is opposite to the direction of the
shunt flux, then the motor is said to be differentially compounded. Characteristics of both these
compound motors are explained below.
Cumulative compound motors are used where series characteristics are required but the load is likely
to be removed completely. Series winding takes care of the heavy load, whereas the shunt winding
prevents the motor from running at dangerously high speed when the load is suddenly removed. These
motors have generally employed a flywheel, where sudden and temporary loads are applied like in
rolling mills.
Since in differential field motors, series flux opposes shunt flux, the total flux decreases with increase
in load. Due to this, the speed remains almost constant or even it may increase slightly with increase
in load (N Eb/ɸ). Differential compound motors are not commonly used, but they find limited
applications in experimental and research work.
56
Now, when the motor is at rest, obviously, there is no back emf Eb, hence armature
current will be high at starting.
1. blow out the fuses and may damage the armature winding and/or commutator brush
arrangement.
2. produce very high starting torque (as torque is directly proportional to armature current), and
this high starting toque will produce huge centrifugal force which may throw off the armature
windings.
Thus to avoid above two drawbacks, starters are used for starting of DC machine.
Thus, to avoid the above dangers while starting a DC motor, it is necessary to limit the starting
current. For that purpose, starters are used to start a DC motor. There are various starters like, 3 point
starter, 4 point starter, No load release coil starter, thyristor starter etc. The main concept behind every
DC motor starter is, adding external resistance to the armature winding at starting.
a) 3 Point Starter
The internal wiring of a 3 point starter is as shown in the figure.
When motor is to be started, the lever is turned gradually to the right. When lever touches point 1, the
field winding gets directly connected across the supply, and the armature winding gets connected with
resistances R1 to R5 in series. Hence at starting full resistance is added in series with armature. Then
as the lever is moved further, the resistance is gradually is cut out from the armature circuit. Now, as
the lever reaches to position 6, all the resistance is cut out from the armature circuit and armature gets
directly connected across the supply. The electromagnet E (no voltage coil) holds the lever at this
position. This electromagnet releases the lever when there is no (or low) supply voltage. When the
motor is overloaded beyond a predefined value, overcurrent release electromagnet D gets activated,
which short circuits electromagnet E , and hence releases the lever and motor is turned off.
57
b) 4 Point Starter:
The main difference between a 3 point starter and a 4 point starter is that the no voltage coil is not
connected in series with field coil. The field gets directly connected to the supply, as the lever moves
touching the brass arc. The no voltage coil (or Hold on coil) is connected with a current limiting
resistance Rh. This arrangement ensures that any change of current in the shunt field does not affect
the current through hold on coil at all. This means that electromagnet pull of the hold-on coil will
always be sufficient so that the spring does not unnecessarily restore the lever to the off position.
This starter is used where field current is to be adjusted by means of a field rheostat.
Construction of DC series motor starters is very basic as shown in the figure. A start arm is simply
moved towards right to start the motor. Thus at first maximum resistance is connected in series with
the armature and then gradually decreased as the start arm moves towards right.
The no load release coil holds the start arm to the run position and leaves it at no load.
A dc generator converts mechanical power into electrical power and a dc motor converts electrical
power into mechanical power. Thus, for a dc generator, input power is in the form of mechanical and
the output power is in the form of electrical. On the other hand, for a dc motor, input power is in the
form of electrical and output power is in the form of mechanical. In a practical machine, whole of the
input power cannot be converted into output power as some power is lost in the process. This causes
the efficiency of the machine to be reduced. Efficiency is the ratio of output power to the input power.
Thus, in order to design rotating dc machines with higher efficiency, it is important to study the losses
occurring in them.
58
Various losses in a rotating DC machine (DC generator or DC motor) can be characterized as
follows:
Copper losses
Armature Cu loss
Field Cu loss
Loss due to brush contact resistance
Iron Losses
Hysteresis loss
Eddy current loss
Mechanical losses
Friction loss
Windage loss
The above tree categorizes various types of losses that occur in a dc generator or a dc motor.
Each of these is explained in details below.
a) Copper Losses
These losses occur in armature and field copper windings. Copper losses consist of Armature copper
loss, Field copper loss and loss due to brush contact resistance.
Armature copper loss = Ia2Ra (where, Ia = Armature current and Ra = Armature resistance)
This loss contributes about 30 to 40% to full load losses. The armature copper loss is variable and
depends upon the amount of loading of the machine.
In the case of a shunt wounded field, field copper loss is practically constant. It contributes about 20
to 30% to full load losses.
Brush contact resistance also contributes to the copper losses. Generally, this loss is included into
armature copper loss.
As the armature core is made of iron and it rotates in a magnetic field, a small current gets induced in
the core itself too. Due to this current, eddy current loss and hysteresis loss occur in the armature iron
core. Iron losses are also called as Core losses or magnetic losses.
Hysteresis loss is due to the reversal of magnetization of the armature core. When the core passes
under one pair of poles, it undergoes one complete cycle of magnetic reversal. The frequency of
magnetic reversal if given by, f=P.N/120 (where, P = no. of poles and N = Speed in rpm)
The loss depends upon the volume and grade of the iron, frequency of magnetic reversals and value of
flux density. Hysteresis loss is given by, Steinmetz formula:
Eddy current loss: When the armature core rotates in the magnetic field, an emf is also induced in
the core (just like it induces in armature conductors), according to the Faraday's law of
electromagnetic induction. Though this induced emf is small, it causes a large current to flow in the
body due to the low resistance of the core. This current is known as eddy current. The power loss due
to this current is known as eddy current loss.
59
c) Mechanical Losses
Mechanical losses consist of the losses due to friction in bearings and commutator. Air friction loss of
rotating armature also contributes to these.
Stray Losses
In addition to the losses stated above, there may be small losses present which are called as stray
losses or miscellaneous losses. These losses are difficult to account. They are usually due to
inaccuracies in the designing and modeling of the machine. Most of the times, stray losses are
assumed to be 1% of the full load.
The most convenient method to understand these losses in a dc generator or a dc motor is using the
power flow diagram. The diagram visualizes the amount of power that has been lost in various types
of losses and the amount of power which has been actually converted into the output. Following are
the typical power flow diagrams for a dc generator and a dc motor.
It is a constant speed motor. Where the speed is required to remain almost constant from no load to
full load. Where the load has to be driven at a number of speeds and any one of which is nearly
constant.
Industrial use:
60
Lathes
Drills
Boring mills
Shapers
Spinning and weaving machines.
It is a variable speed motor. The speed is low at high Page on torque at light or no load ,the motor
speed attains dangerously high speed. The motor has a high starting torque.(elevators, electric
traction)
Industrial use:
electric traction
cranes
elevators
air compressor
vaccum cleaner
hair dryer
sewing machine
3. D.C. Compound motor: Differential compound motors are rarely used because of its poor torque
characteristics.
Industrial uses:
Presses Shears
Reciprocating machine
61
UNIT III
ALTERNATING QUANTITIES AND AC MACHINES
3.1 INTRODUCTION:
The alternating quantity is one whose value varies with time. This alternating quantity may be
periodic and non-periodic. Periodic quantity is one whose value will be repeated for every specified
interval. Generally to represent alternating voltage or current we prefer sinusoidal wave form, because
below listed properties
3.3 Definitions:
Peak to peak value: It is total value from positive peak to the negative peak.(2Vm)
Instantaneous value: It is the magnitude of wave form at any specified time. V(t)
62
Hence it is defined for half cycle.
Vd = (1 / Π) ʃ Vm sin wt.dwt
= 2Vm / Π
RMS value:
= Vm / = effective value.
Peak factor:
It is the ratio of peak value to the rms value.
Pp = Vp / Vrms =
Form factor:
It is the ratio of average value to the rms value.
Fp = Vd / Vrms = 2 / Π = 1.11
Eg: Find the peak, peak to peak, average, rms, peak factor and form factor of given current function ,
i(t) = 5 sin wt.
Phase difference is the difference of phase between two wave forms taking one as reference.
Eg: If wave form A is Vm sin (wt+15), B is Vm sin (wt – 30) and C is Vm sin (wt + 45).
Determine the phase difference between every pair if wave forms.
When A and B are compared , phase difference is 45 degrees.
When C and B are compared , phase difference is 75 degrees.
When A and C are compared , phase difference is 30 degrees.
63
3.6 Phase relations of network parameters:
Resistor:
Let us consider resistor allowing alternating current i(t). Then the voltage drop across resistor is given
as,
If, V(t) = Vm sin wt
V(t) = i(t).R
i(t) = V(t) / R
= Vm sin wt / R
i(t) = Im sin wt.
The ratio of V(t) / i(t) = Z = impedance offered by resistor.(ohms).
Z = Vm sin wt / Im sin wt.
= Vm / Im
Hence we can say that V(t) and i(t) in resistor element are in phase.
Inductor:
Capacitor:
In the case of DC circuits power is given as product of voltage and current in that element.
P = V.I (W)
Let V(t) = Vm sin wt
64
i(t) = Im sin(wt +90)
Instantaneous power, P (t) = V (t).i (t)
= Vm sin wt. Im sin(wt + Ф)
= Vm.Im sin wt sin (wt + Ф).
Cos Ф = Pav / Pa
Z = R + jXL
I2 Z = I2R + j I2XL
65
Z = R - jXC
S = V(t).i(t)*
= P+jQ or P-jQ
Q = reactive power
Here only useful power is true power where as net reactive power over an cycle will be zero.
3.9 Complex numbers:
Complex numbers can be represented in two ways, either rectangle form or polar form
Rectangular form = a + j b
Polar form = tan-1 (b/a)
Here j operator plays major role in complex number, which is define unit vector rotating in anti-clock
wise direction with phase 90.
j=1 =
j2 = -1
j3 = -
66
Adding the potentials around the circuit:
67
Example
A 240V, 250/π Hz supply is connected in series with 60R, 180mH and 50μF. Take
the emf as the reference phase and find:
(a) the complex impedance of the circuit
(b) the complex, real (i.e. physical) and rms currents, and
(c) the complex, real (i.e. physical) and rms potential differences across each
element.
68
The complex impedance for the circuit is 78.1 Ω, and the phase angle between current and applied emf
is 0.69 radians (or 39.80).
69
Complex potentials and currents hold both magnitude and phase information.
Resistor/Capacitor and Resistor/Inductor circuits can form filters to block high or low frequency
signals.
Average Power is calculated with rms quanties.Apparent Power is the product of applied emf and
current.Real Power is the product of applied emf, current and cos(the phase angle between emf and
current) (in Watt). cos(phase angle between emf and current) is called the power factor.Apparent and
Complex power are given the unit VA (Volt Amp).Reactive Power is given the unit VAR (Volt Amp
Reactive).
However, the analysis of a parallel RLC circuits can be a little more mathematically difficult than for
series RLC circuits so in this tutorial about parallel RLC circuits only pure components are assumed in
this tutorial to keep things simple.
This time instead of the current being common to the circuit components, the applied voltage is now
common to all so we need to find the individual branch currents through each element. The total
impedance, Z of a parallel RLC circuit is calculated using the current of the circuit similar to that for a
DC parallel circuit, the difference this time is that admittance is used instead of impedance. Consider
the parallel RLC circuit below.
In the above parallel RLC circuit, we can see that the supply voltage, V S is common to all three
components whilst the supply current IS consists of three parts. The current flowing through the
resistor, IR, the current flowing through the inductor, IL and the current through the capacitor, IC.
But the current flowing through each branch and therefore each component will be different to each
other and to the supply current, IS. The total current drawn from the supply will not be the
mathematical sum of the three individual branch currents but their vector sum.
70
Like the series RLC circuit, we can solve this circuit using the phasor or vector method but this time
the vector diagram will have the voltage as its reference with the three current vectors plotted with
respect to the voltage. The phasor diagram for a parallel RLC circuit is produced by combining
together the three individual phasors for each component and adding the currents vectorially.
Since the voltage across the circuit is common to all three circuit elements we can use this as the
reference vector with the three current vectors drawn relative to this at their corresponding angles. The
resulting vector IS is obtained by adding together two of the vectors, IL and IC and then adding this sum
to the remaining vector IR. The resulting angle obtained between V and IS will be the circuits phase
angle as shown below.
Phasor Diagram for a Parallel RLC Circuit
We can see from the phasor diagram on the right hand side above that the current vectors produce a
rectangular triangle, comprising of hypotenuse IS, horizontal axis IRand vertical axis IL – IC Hopefully
you will notice then, that this forms a Current Triangle and we can therefore use Pythagoras’s
theorem on this current triangle to mathematically obtain the magnitude of the branch currents along
the x-axis and y-axis and then determine the total current IS of these components as shown.
Since the voltage across the circuit is common to all three circuit elements, the current through each
branch can be found using Kirchoff’s Current Law, (KCL). Kirchoff’s current law or junction law
states that “the total current entering a junction or node is exactly equal to the current leaving that
node”, so the currents entering and leaving node “A” above are given as:
71
Taking the derivative, dividing through the above equation by C and rearranging gives us the
following Second-order equation for the circuit current. It becomes a second-order equation because
there are two reactive elements in the circuit, the inductor and the capacitor.
You will notice that the final equation for a parallel RLC circuit produces complex impedance’s for
each parallel branch as each element becomes the reciprocal of impedance, ( 1/Z ) with the reciprocal
of impedance being called Admittance.
In parallel AC circuits it is more convenient to use admittance, symbol ( Y ) to solve complex branch
impedance’s especially when two or more parallel branch impedance’s are involved (helps with the
math’s). The total admittance of the circuit can simply be found by the addition of the parallel
admittances. Then the total impedance, ZT of the circuit will therefore be 1/YT Siemens as shown.
72
3.11.1 Admittance of a Parallel RLC Circuit
The new unit for admittance is the Siemens, abbreviated as S, ( old unit mho’s ℧, ohm’s in reverse ).
Admittances are added together in parallel branches, whereas impedance’s are added together in series
branches. But if we can have a reciprocal of impedance, we can also have a reciprocal of resistance
and reactance as impedance consists of two components, R and X. Then the reciprocal of resistance is
called Conductance and the reciprocal of reactance is called Susceptance.
3.12 Three Phase AC Circuits
3.12.1 Introduction
Three-phase systems are commonly used in generation, transmission and distribution of electric
power. Power in a three-phase system is constant rather than pulsating and three-phase motors start
and run much better than single-phase motors. A three-phase system is a generator-load pair in which
the generator produces three sinusoidal voltages of equal amplitude and frequency but differing in
There are two types of system available in electric circuit, single phase and three phase system. In
single phase circuit, there will be only one phase, i.e the current will flow through only one wire and
there will be one return path called neutral line to complete the circuit. So in single phase minimum
amount of power can be transported. Here the generating station and load station will also be single
phase. This is an old system using from previous time.
In polyphase system, that more than one phase can be used for generating, transmitting and for load
system. Three phase circuit is the polyphase system where three phases are send together from the
generator to the load. Each phase are having a phase difference of 120°, i.e 120° angle electrically. So
from the total of 360°, three phases are equally divided into 120° each. The power in three phase
system is continuous as all the three phases are involved in generating the total power. The sinusoidal
waves for 3 phase system is shown below The three phases can be used as single phase each. So if the
load is single phase, then one phase can be taken from the three phase circuit and the neutral can be
used as ground to complete the circuit..
v a Vm cos t
v b V m cos t 120
v c Vm cost 240 ,
73
the corresponding phasors are
Va Vm
Vb Vm e j120
Vc Vm e j240 .
1. Star connection
2. Delta connection
When equal current will flow through all the three phases, then it is called as balanced current. And
when the current will not be equal in any of the phase, then it is unbalanced current. In this case,
during balanced condition there will be no current flowing through the neutral line and hence there is
no use of the neutral terminal. But when there will be unbalanced current flowing in the three phase
74
circuit, neutral is having a vital role. It will take the unbalanced current through to the ground and
protect the transformer. Unbalanced current affects transformer and it may also cause damage to the
transformer and for this star connection is preferred for long distance transmission.
In star connection, the line voltage is √3 times of phase voltage. Line voltage is the voltage between
two phases in three phase circuit and phase voltage is the voltage between one phase to the neutral
line. And the current is same for both line and phase. It is shown as expression below
75
In three phase circuit, star and delta connection can be arranged in four different ways-
1. Star-Star connection
2. Star-Delta connection
3. Delta-Star connection
4. Delta-Delta connection
But the power is independent of the circuit arrangement of the three phase system. The net power in
the circuit will be same in both star and delta connection. The power in three phase circuit can be
calculated from the equation below,
Since there is three phases, so the multiple of 3 is made in the normal power equation and the PF is
power factor. Power factor is a very important factor in three phase system and sometimes due to
certain error, it is corrected by using capacitors.
In a balanced system, each of the three instantaneous voltages has equal amplitudes, but is
separated from the other voltages by a phase angle of 120. The three voltages (or phases) are
typically labeled a, b and c. The common reference point for the three phase voltages i s designated
as the neutral connection and is labeled as n.
A three-phase system is shown in Fig. In a special case all impedances are identical
Za = Zb = Zc = Z
Va Vb Vc
Ia Ib Ic .
Z Z Z
76
Using KCL, we have,
Va Vb Vc Vm 1 e j120 e j 240
1 3
3 1
Vm 1 cos120 j sin 120 cos 240 j sin 240 Vm 1 j j 0 .
2 2 2 2
I n I a I b I c Va Vb Vc ,(4)
1
Z
Since the current flowing though the fourth wire is zero, the wire can be removed
Va Ia Z
Vb Ib Z
n n’
Vc Ic Z
Three-phase systems deliver power in enormous amounts to single-phase loads such as lamps,
heaters, air-conditioners, and small motors. It is the responsibility of the power systems engineer to
distribute these loads equally among the three-phases to maintain the demand for power fairly
balanced at all times. While good balance can be achieved on large power systems, individual loads
on smaller systems are generally unbalanced and must be analyzed as unbalanced three phase
systems.
When the three phases of the load are not identical, an unbalanced system is produced. An unbalanced
Y-connected system is shown in Fig.1. The system of Fig.1 contains perfectly conducting wires
connecting the source to the load. Now we consider a more realistic case where the wires are
represented by impedances Zp and the neutral wire connecting n and n’ is represented by impedance Zn
77
the node n as the datum, we express the currents Ia, Ib, Ic and In in terms of the node voltage Vn
Va Vn
Ia
Za Zp
Vb Vn
Ib
Zb Zp
Vc Vn
Ic
Zc Zp
V
In n
Zn
Va Vb Vc
Za Zp Zb Zp Zc Zp
And Vn
1 1 1 1
Zn Za Zp Zb Zp Zc Zp
In the balanced systems, the average power consumed by each load branch is the same and given by
~
Pav Veff Ieff cos
where Veff is the effective value of the phase voltage, Ieff is the effective value of the phase current and
is the angle of the impedance. The total average power consumed by the load is the sum of those
consumed by each branch, hence, we have
~
Pav 3Pav 3Veff Ieff cos
78
In the balanced Y systems, the phase current has the same amplitude as the line current
Ieff Ieff L , whereas the line voltage has the effective value Veff L which is 3 times greater than
the effective value of the phase voltage, Veff L 3Veff . Hence, using (22), we obtain
But we have I1+I2+I3=0, hence putting the value of I1+I2=-I3. We get total power as V1I1+V2I2+V3I3.
For delta connected load, the diagram is shown in below
But V1+V2+V3=0, hence expression for total power will reduce to V1I1+V2I2+V3I3
79
13.16 Measurement of Three Phase Power by One Wattmeter Method
Limitation of this method is that it cannot be applied on unbalanced load. So under this condition we
have I1=I2=I3=I and V1=V2=V3=V.
Two switches are given which are marked as 1-3 and 1-2, by closing the switch 1-3 we get reading of
wattmeter as
80
UNIT IV
SEMICONDUCTOR DIODE AND APPLICATIONS
4.1 INTRODUCTION:
We start our study of nonlinear circuit elements. These elements (diodes and transistors) are made of
semiconductors. A brief description of how semiconductor devices work is rst given to understand
their i v characteristics. You will see a rigorous analysis of semiconductors in the breadth courses.
4.1.2 Semiconductors:
Semiconductor material are mainly made of elements from group IVB of the periodic table like
C (diamond), Si, Ge, SiC. These material have 4 electrons in their outer most electronic shell. Each
atom can form a \covalent" bond with four of its neighbors sharing one electron with that atom. In
this manner, each atom \sees" eight electrons in its outer most electronic shell (4 of its own, and one
from each neighbor), completely lling that shell. It is also possible to form this type of covalent
bond by combining elements from group IIIB (sharing three electrons) with element from group VB
(sharing ve electrons). Examples of these semiconductors are GaAs or AlGaAs and are usually
called \3-5" semiconductors. We focus mostly on Si semiconductors in this class. Figure below
shows this covalent
bond structure for Si. A pair of electrons and holes are slow shown. Note that Si form a
tetrahedron structure and an atom in the center of the tetrahedron share electrons with atoms on the
each vertex. Figure below is a two-dimensional representation of such a structure. The leftgure is for
a pure Si semiconductor and an electron-hole pair is depicted. Both electrons and holes are called
\mobile" carriers as they are responsible for carrying electric current.
If we add a small amount of an element from group VB, such as P, to the semiconductor, we
create a n-type semiconductor and the impurity dopant is called a n-type dopant. Each of these new
atoms also form a covalent bond with four of its neighbors. However, as a n-type dopant has 5 valance
electron, the extra electron will be located in the \empty" energy band. As can be seen, there is no hole
associated with this electron. In addition to electrons from the n-type dopant, there are electron-hair
pair in the solid from the base semiconductor (Si in he above gure) which are generated due to
temperature e ects. In a n-type semiconductor, the number of free electrons from the dopant is much
larger than the number of electrons from electron-hole pairs. As such, a n-type semiconductor is
considerably more conductive than the base semiconductor (in this respect, a n-type semiconductor is
more like a \resistive" metal than a semiconductor).
81
In summary, in a n-type semiconductor there are two charge carriers: \holes" from the base
semiconductor (called the \minority" carriers) and electrons from both the n-type dopant and electron-
hole pairs (called the \majority" carrier).
Similarly, we can create a p-type semiconductor by adding an element from group IIIB, such
as B, to the semiconductor. In this case, the p-type dopant generate holes. We will have two charge
carriers: majority carriers are \holes" from the p-type dopant and electron-hole pairs and minority
carriers are electrons from the base semiconductor (from electron-hole pairs).
The charge carriers (electrons and holes) move in a semiconductor through two mechanisms:
First, charge carriers would move from regions of higher concentration to lower concentration in
order to achieve a uniform distribution throughout the semiconductor. This process is called Diff
usion" and is characterized by the diffusion coefficient, D. Second, charge carriers move under the
influence of an electricfield. This motion is called the drift and is characterized by the mobility.
What is a Diode?
A diode is a device which only allows unidirectional flow of current if operated within a rated
specified voltage level. A diode only blocks current in the reverse direction while the reverse voltage
is within a limited range otherwise reverse barrier breaks and the voltage at which this breakdown
occurs is called reverse breakdown voltage. The diode acts as a valve in the electronic and electrical
circuit. A P-N junction is the simplest form of the diode which behaves as ideally short circuit when it
is in forward biased and behaves as ideally open circuit when it is in the reverse biased. Beside simple
PN junction diodes, there are different types of diodes although the fundamental principle is more or
less same. So a particular arrangement of diodes can convert AC to pulsating DC, and hence, it is
82
sometimes also called as a rectifier. The name diode is derived from "di-ode" which means a device
having two electrodes.
A simple PN junction diode can be created by doping donor impurity in one portion and acceptor
impurity in other portion of a silicon or germanium crystal block. These make a p n junction at the
middle portion of the block beside which one portion is p type (which is doped by trivalent or acceptor
impurity) and other portion is n type (which is doped by pentavalent or donor impurity). It can also be
formed by joining a p-type (intrinsic semiconductor doped with a trivalent impurity) and n-type
semiconductor (intrinsic semiconductor doped with a pentavalent impurity) together with a special
fabrication technique such that a p-n junction is formed. Hence, it is a device with two elements, the p-
type forms anode and the n-type forms the cathode. These terminals are brought out to make the
external connections.
In a PN junction diode when the forward voltage is applied i.e. positive terminal of a source is
connected to the p-type side, and the negative terminal of the source is connected to the n-type side,
the diode is said to be in forward biased condition. We know that there is a barrier potential across the
junction. This barrier potential is directed in the opposite of the forward applied voltage. So a diode
can only allow current to flow in the forward direction when forward applied voltage is more than
barrier potential of the junction. This voltage is called forward biased voltage. For silicon diode, it is
0.7 volts. For germanium diode, it is 0.3 volts. When forward applied voltage is more than this
forward biased voltage, there will be forward current in the diode, and the diode will become short
83
circuited. Hence, there will be no more voltage drop across the diode beyond this forward biased
voltage, and forward current is only limited by the external resistance">resistance connected in series
with the diode. Thus, if forward applied voltage increases from zero, the diode will start conducting
only after this voltage reaches just above the barrier potential or forward biased voltage of the
junction. The time taken by this input voltage to reach that value or in other words the time taken by
this input voltage to overcome the forward biased voltage is called recovery time.
Now if the diode is reverse biased i.e. positive terminal of the source is connected to the n-type end,
and the negative terminal of the source is connected to the p-type end of the diode, there will be no
current through the diode except reverse saturation current. This is because at the reverse biased
condition the depilation layer of the junction becomes wider with increasing reverse biased voltage.
Although there is a tiny current flowing from n-type end to p-type end in the diode due to minority
carriers. This tiny current is called reverse saturation current. Minority carriers are mainly thermally
generated electrons and holes in p-type semiconductor and n-type semiconductor respectively. Now if
reverse applied voltage across the diode is continually increased, then after certain applied voltage the
depletion layer will destroy which will cause a huge reverse current to flow through the diode. If this
current is not externally limited and it reaches beyond the safe value, the diode may be permanently
destroyed. This is because, as the magnitude of the reverse voltage increases, the kinetic energy of the
minority charge carriers also increase. These fast moving electrons collide with the other atoms in the
device to knock-off some more electrons from them. The electrons so released further release much
more electrons from the atoms by breaking the covalent bonds. This process is termed as carrier
multiplication and leads to a considerable increase in the flow of current through the p-n junction. The
associated phenomenon is called Avalanche Breakdown.
1) Zener diode
2) P-N junction diode
84
3) Tunnel diode
4) Varractor diode
5) Schottky diode
6) Photo diode
7) PIN diode
8) Laser diode
9) Avalanche diode
10) Light emitting diode
Semiconductor materials (Si, Ge) are used to form variety of electronic devices. The most basic device
is diode. Diode is a two terminal P-N junction device. P-N junction is formed by bringing a P type
material in contact with N type material.When a P-type material is brought in contact with N- type
material electrons and holes start recombining near the junction. This result in lack of charge carriers
at the junction and thus the junction is called depletion region. Symbol of P-N junction is given as:
Biased i.e. when voltage is applied across the terminals of P-N junction, it is called diode.
Diode is unidirectional device that allows the flow of current in one direction only depending on the
biasing.
85
Positive terminal of the battery repels majority carriers, holes, in P-region and negative terminal repels
electrons in the N-region and push them towards the junction. This result in increase in concentration
of charge carriers near junction, recombination takes place and width of depletion region decreases.
As forward bias voltage is raised depletion region continues to reduce in width, and more and more
carriers recombine. This results in exponential rise of current.
Negative terminal of the battery attracts majority carriers, holes, in P-region and positive terminal
attracts electrons in the N-region and pull them away from the junction. This result in decrease in
concentration of charge carriers near junction and width of depletion region increases. A small amount
of current flow due to minority carriers, called as reverse bias current or leakage current. As reverse
bias voltage is raised depletion region continues to increase in width and no current flows. It can be
concluded that diode acts only when forward biased. Operation of diode can be summarized in form of
I-V diode characteristics graph. For reverse bias diode, V<0, ID = IS Where, V = supply voltage ID =
diode current IS = reverse saturation current For forward bias, V > 0, ID = IS(eV/NVT - 1)
Where,
VT = volt’s equivalent of temperature = KT/Q = T/11600
Q = electronic charge = 1.632 X 10 - 19 C
K = Boltzmann’s constant = 1.38 X 10 - 23
N = 1, for Ge
= 2, for Si
86
As reverse bias voltage is further raised, depletion region width increases and a point comes when
junction breaks down. This results in large flow of current. Breakdown is the knee of diode
characteristics curve. Junction breakdown takes place due to two phenomena
Where
It is observed that Ge diodes has smaller cut-in-voltage when compared to Si diode. The
reverse saturation current in Ge diode is larger in magnitude when compared to silicon diode.
When, V is positive the junction is forward biased and when V is negative, the junction is
reversing biased. When V is negative and less than VTH, the current is very small. But when
V exceeds VTH, the current suddenly becomes very high. The voltage VTH is known as
threshold or cut in voltage. For Silicon diode VTH = 0.6 V. At a reverse voltage
corresponding to the point P, there is abrupt increment in reverse current. The PQ portion of
the characteristics is known as breakdown region.
87
4.6 P-N Junction Band Diagram
For an n-type semiconductor, the Fermi level EF lies near the conduction band edge. EC but for an p -
type semiconductor, EF lies near the valance band edge EV.
Now, when a p-n junction is built, the Fermi energy EF attains a constant value. In this scenario the p-
sides conduction band edge. Similarly n–side valance band edge will be at higher level than Ecn, n-
sides conduction band edge of p - side. This energy difference is known as barrier energy. The barrier
energy is EB = Ecp - Ecn = Evp - Evn
If we apply forward bias voltage V, across junction then the barrier energy decreases by an amount of
eV and if V is reverse bias is applied the barrier energy increases by eV.
88
4.6.1 P-N Junction Diode Equation
The p-n junction diode equation for an ideal diode is given below
I = IS[exp(eV/KBT) - 1]
Here,
e = charge of electron
KB = Boltzmann constant
I = IS[exp(eV/ɳKBT) - 1]
Here,
Electric current flows through a p - n junction diode when it is forward biased and we get output
current through the load. Let, we supply a sinusoidal voltage Vin = Vsinωt as a source voltage. Now, if
the input voltage is positive, the diode is forward biased and when that is negative, the diode is in
reverse bias condition. When the input voltage is positive, i.e, for the positive cycle of the input
voltage, the current flows through the diode.
89
So, the current will flow through the load also and we obtain output voltage across the load. But for
the negative half cycle of the input, the p-n junction get reverse biased and no current flows through
the diode as a result we obtain zero current and zero voltage across the load.
90
Now, different parameters for half wave rectifier is given below
The diode works only when it is in forward bias, only the current flows through p-n junction diode and
output current across the load is found. If two diodes are connected in such a way that one diode
conducts during one half of the input voltage and the other one conducts during the next half of the
cycle, in a unidirectional can flow through the load during the full cycle of the impact voltage. This is
known as full wave rectifier.
According to the diagram given below a center tapped transformer D1, and D2 are two p-n junction
diodes with similar characteristics D1 conducts for negative half of the output voltage. Thus we get
output voltage and the output current for the entire input cycle.
The circuit diagram of the full wave diode rectifier given below,
Full wave rectification can also be achieved using a bridge rectifier which is made of four diodes.
91
According to the figure, when D1 and D3 are forward biased, they conduct but D2 and D4 and on D1
and D3 are reverse biased in both cases load current in the same direction.
Bridge rectifier has several advantages over simple full wave rectifier. It performance and efficiency is
better than that of the simple full time rectifier.
Rectifiers are the circuits used to convert alternating current (AC) into direct current (DC). Half-Wave
Rectifiers are designed using a diode (D) and a load resistor (RL) as shown in Figure 1. In these
rectifiers, only one-half of the input waveform is obtained at the output i.e. the output will comprise of
either positive pulses or the negative pulses only. The polarity of the output voltage so obtained
(across RL) depends on the direction of the diode used in the circuit of half-wave rectifier. This is
evident from the figure as Figure 1a shows the output waveform consisting of only positive pulses
while the Figure 1b has only negative pulses in its output waveform.
92
This is because, in Figure 1a the diode gets forward biased only during the positive pulse of the input
which causes the current to flow across RL, producing the output voltage.
Further for the same case, if the input pulse becomes negative, then the diode will be reverse biased
and hence there will be no current flow and no output voltage. Similarly for the circuit shown in
Figure 1b, the diode will be forward biased only when the input pulse is negative, and thus the output
voltage will contain only the negative pulses. Further it is to be noted that the input to the half-wave
rectifier can be supplied even via the transformer. This is advantageous as the transformer provides
isolation from the power line as well as helps in obtaining the desired level of DC voltage. Next, one
can connect a capacitor across the resistor in the circuit of half wave rectifier to obtain a smoother DC
output (Figure 2). Here the capacitor charges through the diode D during the positive pulse of the
input while it discharges through the load resistor RL when the input pulse will be negative. Thus the
output waveform of such a rectifier will have ripples in it as shown in the figure.
Further, for half-wave rectifier, rms voltage is given as Vm/2 which results in the ripple factor of
1.21.
4. Efficiency: It is the ratio of DC output power to the AC input power and is equal to 40.6 %.
5. Transformer Utilization Factor: It is the ratio of DC power delivered to the load to the AC rating
of the transformer secondary and is equal to 0.287.
93
6. Form Factor: This is the ratio of rms value to the average value and is thus equal to 1.57 for half-
wave rectifier.
7. Peak Factor: It is the ratio of peak value to the rms value and is equal to 2.
Half wave rectifiers are advantageous as they are cheap, simple and easy to construct. These are quite
rarely used as they have high ripple content in their output. However they can be used in non-critical
applications like those of charging the battery. They are also less preferred when compared to other
rectifiers as they have low output power, low rectification efficiency and low transformer utilization
factor. In addition, if AC input is fed via the transformer, then it might get saturated which inturn
results in magnetizing current, hysteresis loss and/or result in the generation of harmonics. Lastly it is
important to note that the explanation provided here applies only for the case where the diode is ideal.
Although for a practical diode, the basic working remains the same, one will have to consider the
voltage drop across the diode as well as its reverse saturation current into consideration during the
analysis.
The circuit can be analyzed by considering its working during the positive and the negative input
pulses separately.
Figure 2a shows the case where the AC pulse is positive in nature i.e. the polarity at the top of the
primary winding is positive while its bottom will be negative in polarity. This causes the top part of
the secondary winding to acquire a positive charge while the common centre-tap terminal of the
transformer will become negative.
94
This causes the diode D1 to be forward biased which inturn causes the flow of current through R L
along the direction shown in Figure 2a. However at the same time, diode D2 will be reverse biased and
hence acts like an open circuit. This causes the appearance of positive pulse across the R L, which will
be the DC output. Next, if the input pulse becomes negative in nature, then the top and the bottom of
the primary winding will acquire the negative and the positive polarities respectively. This causes the
bottom of the secondary winding to become positive while its centre-tapped terminal will become
negative. Thus the diode D2 gets forward biased while the D1 will get reverse biased which allows the
flow of current as shown in the Figure 2b. Here the most important thing to note is the fact that the
direction in which the current flows via RL will be identical in either case (both for positive as well as
for negative input pulses). Thus we get the positive output pulse even for the case of negative input
pulse (Figure 3), which indicates that both the half cycles of the input AC are rectified.
Such circuits are referred to as (i) Centre-Tapped Full Wave Rectifiers as they use a centre-tapped
transformer, (ii) Two-Diode Full-Wave Rectifiers because of the use of two diodes and/or (iii) Bi-
Phase Circuits due to the fact that in these circuits, the output voltage will be the phasor addition of the
voltages developed across the load resistor due to two individual diodes, where each of them conducts
only for a particular half-cycle. However as evident from Figure 3, the output of the rectifier is not
pure DC but pulsating in nature, where the frequency of the output waveform is seen to be double of
that at the input. In order to smoothen this, one can connect a capacitor across the load resistor as
shown by the Figure 4. This causes the capacitor to charge via the diode D1 as long as the input
positive pulse increases in its magnitude. By the time the input pulse reaches the positive maxima, the
capacitor would have charged to the same magnitude. Next, as long as the input positive pulse keeps
95
decreasing, the capacitor tries to hold the charge acquired (being an energy-storage element).
However there will be voltage-loss as some amount of charge gets lost through the path provided by
the load resistor (nothing but discharging phenomenon). Further, as the input pulse starts to go low to
reach the negative maxima, the capacitor again starts to charge via the path provided by the diode D 2
and acquires an almost equal voltage but with opposite polarity. Next, as the input voltage starts to
move towards 0V, the capacitor slightly discharges via RL. This charge-discharge cycle of the
capacitor causes the ripples to appear in the output waveform of the full-wave rectifier with RC filter
as shown in Figure 4.
Different parameters and their values for the centre-tapped full-wave rectifiers are
1. Peak Inverse Voltage (PIV): This is the maximum voltage which occurs across the diodes when
they are reverse biased. Here it will be equal to twice the peak of the input voltage, 2Vm.
2. Average Voltage: It is the DC voltage available across the load and is equal to 2V m/π. The
corresponding DC current will be 2Im/π, where Im is the maximum value of the current.
3. Ripple Factor (r): This is the ratio of the root mean square (rms) value of AC component to the dc
component at the output. It is given by
and will be equal to 0.482 as the rms voltage for a full-wave rectifier is given as
4. Efficiency: This is the ratio of DC output power to the AC input power and is equal to 81.2 %.
5. Transformer Utilization Factor (TUF): This factor is expressed as the ratio of DC power
delivered to the load to the AC rating of the transformer secondary. For the full-wave rectifier this
will be 0.693.
6. Form Factor: This is the ratio of rms value to the average value and is equal to 1.11.
7. Peak Factor: It is the ratio of peak value to the rms value and is equal to √2 for the full-wave
rectifiers.
Further it is to be noted that the two-diode full-wave rectifier shown in Figure 1 is costly and bulky in
size as it uses the complex centre-tapped transformer in its design. Thus one may resort to another
type of full-wave rectifier called Full-Wave Bridge Rectifier (identical to Bridge Rectifier) which
might or might not involve the transformer (even if used, will not be as complicated as a centre-tap
one). It also offers higher TUF and higher PIV which makes it ideal for high power applications.
However it is to be noted that the full wave bridge rectifier uses four diodes instead of two, which in
turn increases the magnitude of voltage drop across the diodes, increasing the heating loss. Full wave
rectifiers are used in general power supplies, to charge a battery and to provide power to the devices
like motors, LEDs, etc. However due to the ripple content in the output waveform, they are not
96
preferred for audio applications. Further these are advantageous when compared to half-wave
rectifiers as they have higher DC output power, higher transformer utilization factor and lower ripple
content, which can be made more smoother by using π-filters. All these merits mask-up its demerit of
being costly in comparison to the half-wave rectifiers due to the use of increased circuit elements. At
last, it is to be noted that the explanation provided here considers the diodes to be ideal in nature. So,
incase of practical diodes, one will have to consider the voltage drop across the diode, its reverse
saturation current and other diode characteristics into account and reanalyze the circuit. Nevertheless
the basic working remains the same.
Bridge Rectifiers are the circuits which convert alternating current (AC) into direct current (DC)
using the diodes arranged in the bridge circuit configuration. They usually comprise of four or more
number of diodes which cause the output generated to be of the same polarity irrespective of the
polarity at the input. Figure 1 shows such a bridge rectifier composed of four diodes D1, D2, D3 and D4
in which the input is supplied across two terminals A and B in the figure while the output is collected
across the load resistor RL connected between the terminals C and D.
Now consider the case wherein the positive pulse appears at the AC input i.e. the terminal A is
positive while the terminal B is negative. This causes the diodes D1 and D3 to get forward biased and
at the same time, the diodes D2 and D4 will be reverse biased.
As a result, the current flows along the short-circuited path created by the diodes D1 and D3
(considering the diodes to be ideal), as shown by Figure 2a. Thus the voltage developed across the
load resistor RL will be positive towards the end connected to terminal D and negative at the end
connected to the terminal C.
97
Next if the negative pulse appears at the AC input, then the terminals A and B are negative and
positive respectively. This forward biases the diodes D2 and D4, while reverse biasing D1 and D3
which causes the current to flow in the direction shown by Figure 2b. At this instant, one has to note
that the polarity of the voltage developed across RL is identical to that produced when the incoming
AC pulse was positive in nature. This means that for both positive and negative pulse, the output of
the bridge rectifier will be identical in polarity as shown by the wave forms in Figure 3.
However it is to be noted that the bridge rectifier's DC will be pulsating in nature. In order to obtain
pure form of DC, one has to use capacitor in conjunction with the bridge circuit (Figure 4).
In this design, the positive pulse at the input causes the capacitor to charge through the diodes D1 and
D3. However as the negative pulse arrives at the input, the charging action of the capacitor ceases and
it starts to discharge via RL. This results in the generation of DC output which will have ripples in it as
shown in the figure. This ripple factor is defined as the ratio of AC component to the DC component
in the output voltage. In addition, the mathematical expression for the ripple voltage is given by the
equation
Further, the bridge rectifiers can be majorly of two types, viz., Single-Phase Rectifiers and Three-
Phase Rectifiers. In addition, each of these can be either Uncontrolled or Half-Controlled or Full-
Controlled. Bridge rectifiers for a particular application are selected by considering the load current
requirements. These bridge rectifiers are quite advantageous as they can be constructed with or
without a transformer and are suitable for high voltage applications. However here two diodes will be
conducting for every half-cycle and thus the voltage drop across the diodes will be higher. Lastly one
has to note that apart from converting AC to DC, bridge rectifiers are also used to detect the
amplitude of modulated radio signals and to supply polarized voltage for welding applications.
98
UNIT V
5.1 INTRODUCTION
The transistor was invented in 1947 by John Bardeen, Walter Brattain and William Shockley at
Bell Laboratory in America. A transistor is a semiconductor device, commonly used as an Amplifier
or an electrically Controlled Switch.
In Unipolar transistor, the current conduction is only due to one type of carriers i.e., majority
charge carriers. The current conduction in bipolar transistor is because of both the types of charge
carriers i.e., holes and electrons. Hence it is called as Bipolar Junction Transistor and it is referred to
as BJT.
BJT is a semiconductor device in which one type of semiconductor material is sand witched
between two opposite types of semiconductor i.e., an n-type semiconductor is sandwiched between
two p-type semiconductors or a p-type semiconductor is sandwiched between two n-type
semiconductor.
Hence the BJTs are of two types.They are:
1) n-p-n Transistor
2) p-n-p Transistor
The arrow head represents the conventional current direction from p to n. Transistor has three
terminals.
1) Emitter 2) Base 3) Collector
99
Base: The charge carriers emitted by the emitter should reach collector passing through the base.
Hence base should be very thin and to avoid recombination, and to provide more collector current base
is lightly doped.
Collector: Collector has to collect the most of charge carriers emitted by the emitter. Hence the area
of cross section of collector is more compared to emitter and it is moderately doped.
Transistor can be operated in three regions.
1) Active region.
2) Saturation region.
3) Cut-Off region.
Active Region: For the transistor to operate in active region base to emitter junction is forward biased
and collector to base junction is reverse biased.
Saturation Region: Transistor to be operated in saturation region if both the junctions i.e., collector to
base junction and base to emitter junction are forward biased.
Cut-Off Region: For the transistor to operate in cut-off region both the junctions i.e., base to emitter
junction and collector to base junction are reverse biased.
Transistor can be used as
1) Amplifier 2) Switch
For the transistor to act as an amplifier, it should be operated in active region. For the transistor to act
as a switch, it should be operated in saturation region for ON state, and cut-off region for OFF state.
5.2 TRANSISTOR OPERATION:
Working of a n-p-n transistor:
The n-p-n transistor with base to emitter junction forward biased and collector base junction reverse
biased is as shown in figure.
As the base to emitter junction is forward biased the majority carriers emitted by the n type emitter
i.e., electrons have a tendency to flow towards the base which constitutes the emitter
Current IE As the base is p-type there is chance of recombination of electrons emitted by the emitter
with the holes in the p-type base. But as the base is very thin and lightly doped only few electrons
emitted by the n-type emitter less than 5% combines with the holes in the p-type base, the remaining
more than 95% electrons emitted by the n-type emitter cross over into the collector region constitute
the collector current. The current distributions are as shown in fig IE = IB + IC
Working of a p-n-p transistor:
The p-n-p transistor with base to emitter junction is forward biased and collector to base junction
reverse biased is as show in figure. As the base to emitter junction is forward biased the majority
carriers emitted by the type emitter i.e., holes have a tendency to flow towards the base which
constitutes the emitter current IE. As the base is n-type there is a chance of recombination of holes
emitted by the emitter with the electrons in the n-type base. But as the base us very thin and lightly
doped only few electrons less than 5% combine with the holes emitted by the p-type emitter, the
100
remaining 95% charge carriers cross over into the collector region to constitute the collector current.
The current distributions are shown in figure.
IE = IB + IC
Current components in a transistor:
The figure below shows the various current components which flow across the forward biased emitter
junction and reverse-biased collector junction in P-N-P transistor
Figure. Current components in a transistor with forward-biased emitter and reverse-biased Collector
junctions. The emitter current consists of the following two parts:
1) Hole current IpE constituted by holes (holes crossing from emitter into base).
2) Electron current InE constituted by electrons (electrons crossing from base into the emitter).
When the emitter is open-circuited, IE=0, and hence IpC=0. Under this condition, the base and
collector together current IC equals the reverse saturation current ICO, which consists of the following
two parts: IPCO caused by holes moving across IC from N-region to P-region.
InCO caused by electrons moving across IC from P-region to N-region. ICO = InCO + IpCO
In general,
IC = InC + IpC
Thus for a P-N-P transistor,
IE = IB + IC
101
Fig. Common – Base configuration
When no signal is applied, then the ratio of the collector current to the emitter current is
called dc alpha (α dc) of a transistor.
102
(Negative sign signifies that IE flows into transistor while IC flows out of it). ‘ α’ of a transistor is a
measure of the quality of a transistor. Higher is the value of ‘α ’, better is the transistor in the sense
that collector current approaches the emitter current. By considering only magnitudes of the currents,
IC = a IE and hence IB = IE - IC
Therefore,
IB = IE -a IE = IE(1-a ) …………. (2)
When signal is applied, the ratio of change in collector current to the change in emitter current at
constant collector-base voltage is defined as current amplification factor,
For all practical purposes, dc a =aac =a and practical values in commercial transistors range from 0.9
to 0.99.
In this configuration, the input signal is applied between base and emitter and the output is taken from
collector and emitter. As emitter is common to input and output circuits, hence the name common
emitter configuration.
Figure shows the common-emitter P-N-P transistor circuit.
103
Total Collector Current:
The Total collector current IC = β IB + ICEO ………… (3)
Where ICEO is the leakage current.
In this configuration, the input signal is applied between base and collector and the output is taken
from the emitter. As collector is common to input and output circuits, hence the name common
collector configuration. Figure shows the common collector PNP transistor circuit.
When no signal is applied, then the ratio of emitter current to the base current is called as
dc gamma (γdc) of the transistor.
104
5.4 INPUT CHARACTERISTICS:
To determine the input characteristics, the collector-base voltage VCB is kept constant at zero volts
and the emitter current IE is increased from zero in suitable equal steps by increasing VEB. This is
repeated for higher fixed values of VCB. A curve is drawn between emitter current IE and emitter-
base voltage VEB at constant collector-base voltage VCB.
The input characteristics thus obtained are shown in figure below.
As the collector voltage VCC is made to increase the reverse bias, the space charge width between
collector and base tends to increase, with the result that the effective width of the base
decreases. This dependency of base-width on collector-to-emitter voltage is known as Early effect (or)
Base-Width modulation.
105
5.5 Punch Through (or) Reach Through:
When reverse bias voltage increases more, the depletion region moves towards emitter junction and
effective base width reduces to zero. This causes breakdown in the transistor. This condition is called
“Punch Through” condition.
Output Characteristics:
To determine the output characteristics, the emitter current IE is kept constant at a suitable value by
adjusting the emitter-base voltage VEB. Then VCB is increased in suitable equal steps and the
collector current IC is noted for each value of IE. Now the curves of IC versus VCB are plotted for
constant values of IE and the output characteristics thus obtained is shown in figure below.
Transistor Parameters:
The slope of the CB characteristics will give the following four transistor parameters. Since these
parameters have different dimensions, they are commonly known as common base hybrid parameters
(or) h-parameters.
It is defined as the ratio of change in (input) emitter to base voltage to the change in (input) emitter
current with the (output) collector to base voltage kept constant. Therefore,
It is defined as the ratio of change in the (output) collector current to the corresponding change in the
(output) collector-base voltage, keeping the (input) emitter current IE constant. Therefore,
106
It is the slope of CB output characteristics IC versus VCB.
The typical value of this parameter is of the order of 0.1 to 10μmhos
It is defined as a ratio of the change in the (output) collector current to the corresponding change in the
(input) emitter current keeping the (output) collector voltage VCB constant. Hence,
It is the slope of IC versus IE curve. Its typical value varies from 0.9 to 1.0.
It is the slope of VEB versus VCB curve. Its typical value is of the order of 10-5 to 10-4
The circuit diagram for determining the static characteristic curves of the an N-P-N transistor in the
common emitter configuration is shown in figure below.
107
base junction will increase. Hence he effective width of the base will decrease. This effect causes a
decrease in the base current IB. Hence, to get the same value of IB as that for VCE=0, VBE should be
increased. Therefore, the curve shifts to the right as VCE increases.
Output Characteristics:
To determine the output characteristics, the base current IB is kept constant at a suitable value by
adjusting base-emitter voltage, VBE. The magnitude of collector-emitter voltage VCE is increased in
suitable equal steps from zero and the collector current IC is noted for each setting of VCE. Now the
curves of IC versus VCE are plotted for different constant values of IB. The output characteristics thus
obtained are shown in figure below.
Active Region:
The region where the curves are approximately horizontal is the “Active” region of the CE
configuration. In the active region, the collector junction is reverse biased. As VCE is increased,
reverse bias increase. This causes depletion region to spread more in base than in collector, reducing
the changes of recombination in the base. This increase the value of a dc . This Early effect causes
collector current to rise more sharply with increasing VCE in the active region of output
characteristics of CE transistor.
Saturation Region:
If VCE is reduced to a small value such as 0.2V, then collector-base junction becomes forward biased,
since the emitter-base junction is already forward biased by 0.7V. The input junction in CE
configuration is base to emitter junction, which is always forward biased to operate transistor in active
region. Thus input characteristics of CE configuration are similar to forward characteristics of p-n
junction diode. When both the junctions are forwards
biased, the transistor operates in the saturation region, which is indicated on the output characteristics.
The saturation value of VCE, designated VCE(Sat) , usually ranges between 0.1V to 0.3V.
Cut-Off Region:
When the input base current is made equal to zero, the collector current is the reverse leakage current
ICEO. Accordingly, in order to cut off the transistor, it is not enough to reduce IB=0. Instead, it is
necessary to reverse bias the emitter junction slightly. We shall define cut off as the condition where
the collector current is equal to the reverse saturation current ICO and the emitter current is zero.
108
5.6 TRANSISTOR PARAMETERS:
The slope of the CE characteristics will give the following four transistor parameters. Since these
parameters have different dimensions, they are commonly known as Common emitter hybrid
parameters (or) h-parameters.
It is defined as the ratio of change in (input) base voltage to the change in (input) base current with the
(output) collector voltage (VCE), kept constant. Therefore,
It is defined as the ratio of change in the (output) collector current to the corresponding change in the
(output) collector voltage. With the (input) base current IB kept constant. Therefore,
It is defined as a ratio of the change in the (output) collector current to the corresponding change in the
(input) base current keeping the (output) collector voltage VCE constant. Hence,
It is defined as a ratio of the change in the (input) base voltage and the corresponding change in
(output) collector voltage with constant (input) base current, IB. Hence,
The circuit diagram for determining the static characteristics of an N-P-N transistor in the common
collector configuration is shown in fig. below.
109
Fig. Circuit to determine CC static characteristics.
Input Characteristics:
To determine the input characteristic, VEC is kept at a suitable fixed value. The base collector
voltage VBC is increased in equal steps and the corresponding increase in IB is noted. This is repeated
for different fixed values of VEC. Plots of VBC versus IB for different values of VEC shown in figure
are the input characteristics.
Output Characteristics:
The output characteristics shown in figure below are the same as those of the common emitter
configuration.
110
Problem:
1 A Germanium transistor used in a complementary symmetry amplifier has ICBO=10μA at 27oC and
hfe=50. (a) find IC when IB=0.25mA and (b) Assuming hfe does not increase with temperature; find
the value of new collector current, if the transistor’s temperature rises to 50oC.
a) IC = βIB+(1+β)ICBO
= 50x(0.25x10-3)+(1+50)x(10x10-6)A
=13.01mA
111