NPCP Chapter 4
NPCP Chapter 4
NPCP Chapter 4
Note
Brass or Copper shall not be used for Urinal Tailpiece
or Trap
SECTION 405 PROHIBITED FIXTURES
- Water Closet (prohibited)
inivisible seals, unventilate space and having walls
which are not thoroughly washed at each discharge
- Drinking Fountain
shall not be installed on Public toilet Rooms
- Fixed wooden, Concrete, Tile, WASH TRAYS or SINKS
shall not be installed on buildings for human habitation
Note
The minimum distance bet.the Door or Entry to the drain
opening is 1.2 meters
- Shower Compartments
Area 0.6 m2 (min.)
Encompassing Circle 762 mm diameter
height 1.78 meters (min.)
- Floors of public rooms
shall be non skid surface
- Gutters in public or gang showers shall have pounded corners and
a slope of 2% towards the drain
- Drain in gutters shall be spaced not more than 4.9 meters
- Maximum Temperature of Hot Water
48.48 degrees celsius
- Lead and Copper Sub pan Linings
*materials 6 kgs.of asphalt felt
*unit weight not less than 19.6 kg/m3
*thickness for copper Gauge #24 B&S or 0.5 mm thick
pans
- Joints
Lead pans burned