Amos - Commandline Interface: 1. Getting Started 1.1 Launching Amos From Oss Front Page Gui

Download as pdf or txt
Download as pdf or txt
You are on page 1of 20

AMOS - COMMANDLINE INTERFACE

1. GETTING STARTED

1.1 LAUNCHING AMOS FROM OSS FRONT PAGE GUI

AMOS MOSHELL SESSION IS OPEN DEFAULT FROM USER HOME DIRECTORY IN OSS.

1.2 LAUNCHING AMOS FROM OSS ONE/ OSS NETWORK EXPLORER


THE AMOS SESSION DIRECTLY OPENED INTO R021E NODE.

2. USING AMOS

2.1 THESE ARE THE IP ADDRESSES OF THE RNC .

RNC IP ADDRESS PASSWORD


R021E 10.10.121.133 rnc@1234
R031E 10.17.121.133 rnc@1234
R041E 10.11.121.133 rnc@1234
R051E 10.18.121.133 rnc@1234
R061E 10.8.121.133 rnc@1234
R071E 10.14.121.133 rnc@1234
2.2 AMOS SESSION

USER MAY USE NODE DNS NAME OR IP ADDRESS TO CONNECT TO THE NODE.

WHEN THE IP CONTACT IS OK, BOTH IS ACCESSIBLE.

2.2.1 PLEASE USER SMALL LETTER FOR command initiation throughout the AMOS SESSION.

amos R021E or amos 10.10.121.133

2.2.2 IP Addresses are used when the OSS does not define the updated Node DNS with its IP
Address.

2.2.3 After amos R021E, user must send command “lt all”.

This will refresh and load all MO’s information into the session.

User may notice that for the “amos 10.10.121.133” the effect “lt all”, will later on read the
node userlabel to be R021E.

2.2.4 Command to be used in the RNC session


1. Alarm checking in RNC

alt - Alarm list with time

ala - Alarm list in detail information

alc - Alar list in comma separated value. Useful to import in excel


format
2. Checking NodeB in RNC

lst <NodeB ID>

Normally, Site ID is starting with 2 alphabets follow by 4 digits.

To check all subordinate of a cell, use “lst”.

To check the main element use, ‘st”


To see all site listing in the related RNC, use “str”

To have site listing in CSV format, use “str <any label>”, it will create the file csv format and
need to be transferred from OSS your user folder into your laptop and can be open in excel file
as sample below.

R021E> str UI0401

Output saved to CSV file: UI0401

R021E> !ls UI0401*

UI0401

R021E> !pwd

/home/nakzaidi

File sample after excel extraction:


2014-17-12 Update of command “str”

The implementation of 2nd carrier has cause some confusion to the output command “str”.

It register the fully operational site as only 1 site and the rest, in under the second category –
totally or partially unavailable.

This is due to the 1st carrier utrancells are fully operational and 2nd carrier utrancells are
LOCKED.

The recommendation given to the issue is to monitor closely the red marker CELLNAMES
column.

Detail information here:

Columns:

MOD: this the RNC module that the site is defined in.

IUBLINK: this is the identity of the iublink that the site is using.

CELLNAME: this is the name of the cells that are connected to that IubLink.

the cell names correspond to the respective sectors.

eg: 6306-1/2/3 means that: cell 63061 is connected to SECT1

cell 63062 is connected to SECT2

cell 63063 is connected to SECT3.

CFRPHEM: the first digit is the state of the UtranCell.

the three following digits are the state of the common channels (Fach/Rach/Pch).
the fifth digit (if present) represents the state of the hsdpa channel (Hsdsch).

the sixth digit (if present) represents the state of the enhanced uplink channel (Eul).

the seventh digit (if present) represents the state of the Mbms channel (MbmsCch).

ICDS: the first digit is the state of the IubLink

the second digit is the state of NbapCommon

the third digit is the state of NbapDedicated

Up to P5, the final two digits are the states of NodeSynchTp 1 and 2.

From P6, the final digit is the state of NodeSynch.

TN: The type of transport network used by the IubLink. A=ATM, I=IP, AI=DualStack

States:

- L = Locked

- S = ShuttingDown

- 0 = Unlocked & Disabled

- 1 = Unlocked & Enabled

Please concentrate on the highlighted column only.


3. Blocking/Deblocking a NodeB

To block an utrancell only.

The same when doing with command “bl <utrancell id>”

Also the same when “bl <proxy no>”


To block a site, use “bl <site id>” or “lbl <site id>”

4. Checking NodeB downtime from the log in RNC


-s startdate

lga Alarm log only

lgaj Alarm log with duration.

M* Alarm initiated with Major severity and “*” alarm cease.

5. Checking RNC hardware

“st plug” - listing of main EPB1 board carry NodeB, Ranap,Rnsap traffic

“cabx” - hardware information on board name, serial number, Temperature


In RNC, Slot=3 and Slot=25 is the main controlling board, one in Active and another one must
be in StandbyReady mode. It shown in “cabx” command.

Alarm temperature will trigger if more than 85 Celsius.


R021E> cabx

141213-12:51:16 10.10.121.133 10.0n RNC_NODE_MODEL_U_1_2679 stopfile=/tmp/1411

Please enter Node Password:

...........put /var/opt/ericsson/amos/moshell_logfiles/nakzaidi/logs_moshell/tempfiles/20141213-
113430_1203/lhCmd1411 /d/usr/lhCmd1411 ... OK

.........put /var/opt/ericsson/amos/moshell_logfiles/nakzaidi/logs_moshell/tempfiles/20141213-
113430_1203/lhCmd1411 /d/usr/lhCmd1411 ... OK

===============================================================================================================
=

SMN APN BOARD FAULT OPER MAINT FRO PRODUCTNUMBER REV SERIAL DATE TEMP COREMGR

===============================================================================================================
=

0 1 SCXB3 OFF ON OFF 2 ROJ208395/1 R6B A065078545 20131120

0 2 CMXB3 OFF ON OFF 20 ROJ208392/1 R7D A065083927 20131129


0 3 EPB1 OFF ON OFF 1 ROJ208394/1 R1D CA71543572 20131101 +58C StandbyReady*

0 4 EPB1 OFF ON OFF 5 ROJ208394/1 R1D CA71543575 20131101 +59C

0 5 EPB1 OFF ON OFF 8 ROJ208394/1 R1D CA71543609 20131101 +57C

0 6 EPB1 OFF ON OFF 25 ROJ208394/1 R1D CA71543554 20131101 +62C

0 7 EPB1 OFF ON OFF 14 ROJ208394/1 R1D CA71543616 20131101 +60C

0 8 EPB1 OFF ON OFF 11 ROJ208394/1 R1D CA71543574 20131101 +61C

0 10 EPB1 OFF ON OFF 17 ROJ208394/1 R1D CA71543555 20131101 +56C

0 11 EVOET OFF ON OFF 21 ROJ208467/1 R1E A065082733 20131127 +71C

0 12 EPB1 OFF ON OFF 40 ROJ208394/1 R1D CA71543571 20131101 +59C

0 13 EPB1 OFF ON OFF 37 ROJ208394/1 R1D CA71535377 20131029 +62C

0 14 EPB1 OFF ON OFF 34 ROJ208394/1 R1D CA71535384 20131029 +57C

0 15 EPB1 OFF ON OFF 59 ROJ208394/1 R1D CA71535319 20131029 +57C

0 16 EPB1 OFF ON OFF 28 ROJ208394/1 R1D CA71535303 20131029 +60C

0 17 EPB1 OFF ON OFF 31 ROJ208394/1 R1D A065085201 20131203 +58C

0 18 EPB1 OFF ON OFF 43 ROJ208394/1 R1D A065085218 20131203 +59C

0 19 EPB1 OFF ON OFF 46 ROJ208394/1 R1D A065085224 20131203 +59C

0 20 EPB1 OFF ON OFF 65 ROJ208394/1 R1D A065085223 20131203 +57C

0 22 EPB1 OFF ON OFF 52 ROJ208394/1 R1D CA71535402 20131029 +59C

0 23 EVOET OFF ON OFF 55 ROJ208467/1 R1E A065082702 20131127 +76C

0 24 EPB1 OFF ON OFF 49 ROJ208394/1 R1D CA71543569 20131101 +60C

0 25 EPB1 OFF ON OFF 68 ROJ208394/1 R1D CA71543576 20131101 +62C Active

0 26 EPB1 OFF ON OFF 62 ROJ208394/1 R1D CA71543573 20131101 +62C

0 27 SCXB3 OFF ON OFF 71 ROJ208395/1 R6B A065078544 20131120

0 28 CMXB3 OFF ON OFF 72 ROJ208392/1 R7D A065083936 20131129

---------------------------------------------------------------------------------------------------------------
-EPB1: Alarm limit: 95 degrees Celsius. Alarm cease limit: 85 degrees Celsius

EVOET: Alarm limit: 110 degrees Celsius. Alarm cease limit: 65 degrees Celsius

================================================================

SMN ProductNr Rev Name Date SerialNr

================================================================

0 ROJ6091001/2 R2A BACKPLANE

0 ROJ 609 1001/2 R2A EGEM2 40G BP X912305373

----------------------------------------------------------------
===============================================================================================================
=

SMN APN PORT BOARD FAULT OPER MAINT PRODUCT NR REV SERIAL DATE TEMP

===============================================================================================================
=

---------------------------------------------------------------------------------------------------------------
-

===================================================================================

CONNECTED POS S LED NAME PRODUCT NR REV SERIAL DATE

===================================================================================

000100 LOWER 0 OFF FANUNIT BFB14013/1 R11B X052231145 20130916

002700 UPPER 0 OFF FANUNIT BFB14013/1 R11B X052233720 20130918

000100 1 OFF O/Econv. KDU137557/4 R4A A442737559 20131107

002700 1 OFF O/Econv. KDU137557/4 R4A A442737542 20131107

5. Checking Ranap and Rnsap connectivity.

Ranap have 2 elements

a. Iu-Cs connection – voice traffic and signaling towards core nodes.


b. Iu-Ps connection – packet/internet traffic and signaling

Rnsap carrying RNC to another RNC Iur traffic for call handover, inter RNC neighbour relation.
R021E> st ranap

141213-14:05:22 10.10.121.133 10.0n RNC_NODE_MODEL_U_1_2679 stopfile=/tmp/16330

===================================================================================

Proxy Adm State Op. State MO

===================================================================================

492 1 (ENABLED) TransportNetwork=1,SccpSp=1,SccpScrc=1,SccpApLocal=RanapLocal

7527 1 (ENABLED) RncFunction=1,CnOperator=1,IuLink=PS1,Ranap=GSSZA

7529 1 (ENABLED) RncFunction=1,CnOperator=1,IuLink=PS2,Ranap=GSRHA

7531 1 (ENABLED) RncFunction=1,CnOperator=1,IuLink=PS3,Ranap=GSMDA

7533 1 (ENABLED) RncFunction=1,CnOperator=1,IuLink=PS4,Ranap=GSTZA


7558 1 (ENABLED) RncFunction=1,CnOperator=1,IuLink=CS1,Ranap=MSTDB

7560 1 (ENABLED) RncFunction=1,CnOperator=1,IuLink=CS2,Ranap=MSRHC

7562 1 (ENABLED) RncFunction=1,CnOperator=1,IuLink=CS3,Ranap=MSBEB

7564 1 (ENABLED) RncFunction=1,CnOperator=1,IuLink=CS4,Ranap=MSKZB

===================================================================================

Total: 9 MOs

Or user may use “|” to include both ranap and rnsap listing as above.

M3UA is the IP transport circuit for an SCCP connection from RNC towards the core nodes.

By default in the MCI network, 4 M3ua is define per connection.

Use command “st m3ua”


2.2.5 Command to be used in the NodeB session

1. Alarm checking in NodeB, same as per description in RNC part.

alt - Alarm list with time

ala - Alarm list in detail information

alc - Alar list in comma separated value. Useful to import in excel


format

2. Checking NodeB data

Listing hardware unit


Listing Nbap|sector|carrier|localcell

Listing CV / Configuration Version


Listing frequencyband in NodeB

Checking hardware, serial number and temperature by “cabx”


VSWR is the power return loss of antenna system and most probably having connection
physical problem.

high value when read > 1.5 dBm

RSSI is the Radio Signal Strength Indicator and associate to interference

high value when read > -99.00 dBm/ getting lower than -100.00 dBm reading

2. Block hardware NodeB

Blocking a DUW by using a PROXY NO as below and command “bl <proxy>”


How to know the unit.

You might also like