TEST REPORT 1397

Purpose: To show conformance of Parco nitrile compound 4462-90 to the requirements of ASTM
D2000 M4CH910 A25 B14 EF31 EO15 EO35 Z1 Z2 Z3 Z4. Reference Lab Request
9141.

Sequence: Tests as listed in specification.

Sec. ASTM
of Test
Spec. Physical Property Requirements Result Method

Original Properties
Hardness, Shore A 90 ± 5 91 D2240
Tensile strength, MPa (psi), min. 10.0(1450) 21.6(3127) D412
Ultimate elongation, pct., min. 100 187 D412
Z1 Modulus at 100 pct. elongation, psi Report 2286 D412
Z2 Specific gravity Report 1.30 D297

Heat Aging
A25 70 hours at 125°C (257°F) D865
Hardness change, pts., Shore A 0 to 15 3
Tensile strength change, pct., max. -25 -1
Ultimate elongation change, pct., max. -50 -44

Compression Set, Solid


B14 22 hours at 100°C (212°F) D395
pct. of original deflection, max. 25 15 Method B

Fluid Aging, ASTM Reference Fuel C


EF31 70 hours at 23°C (73°F) D471
Hardness change, pts., Shore A -30 to 0 -28
Tensile strength change, pct., max. -60 -28
Ultimate elongation change, pct., max. -60 -1
Volume change, pct. 0 to 50 37

Fluid Aging, IRM 901 Oil


EO15 70 hours at 125°C (257°F) D471
Hardness change, pts., Shore A 0 to 10 3
Tensile strength change, pct., max. -20 6
Ultimate elongation change, pct., max. -35 -24
Volume change, pct. -15 to 5 -3

Fluid Aging, IRM 903 Oil


EO35 70 hours at 125°C (257°F) D471
Hardness change, pts., Shore A ±10 -2
Tensile strength change, pct., max. -15 -6
Ultimate elongation change, pct., max. -30 -30
Volume change, pct. 0 to 25 5

1 of 2

PARCO, INC., 1801 S. Archibald Ave., Ontario, California 91761 (909) 947-2200 Fax (909) 923-0288
TEST REPORT 1397

Sec. ASTM
of Test
Spec. Physical Property Requirements Result Method

Low Temperature Resistance


Z3 TR-10, °C (°F) Report -9(16) D1329

Differential Scanning Calorimetry


Z4 Glass Transition, Midpoint °C (°F) Report -7(19) D3418

Conclusion: Parco nitrile compound 4462-90 meets the requirements of ASTM D2000 M4CH910 A25
B14 EF31 EO15 EO35 Z1 Z2 Z3 Z4.

Approved by: ___________________________


Carl Horn,
Vice President, Quality

Date testing completed: 04/28/16

Date report issued: 05/05/16