DC972A 226-276kW PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

SCANIA POWER GENERATION engines

DC09 072A. 226-276 kW (253-309 kVA)


Fuel optimized

Standard equipment
• Scania Engine Management System, EMS
• Unit injectors, PDE
• Turbocharger
• Fuel filter and extra pre-filter with water
separator
• Oil filter, full flow
• Centrifugal oil cleaner
• Oil cooler, integrated in block
• Oil filler, in valve cover
• Deep front oil sump
• Oil dipstick, in block
• Magnetic drain plug for oil draining
• Starter, 1-pole 6.0 kW
• Alternator, 1-pole 100A
• Flywheel, SAE 14
• Silumin flywheel housing, SAE 1 flange
• Front-mounted engine brackets
The engines for power generation from Scania are based on a robust design with a • Open crankcase ventilation
strength optimised cylinder block containing wet cylinder liners that can easily be • Operator’s manual

exchanged. Individual cylinder heads with 4 valves per cylinder promotes repairability
and fuel economy. Optional equipment
  The engine is equipped with a Scania developed Engine Management System, EMS, • Cooling package
• Fan
in order to ensure the control of all aspects related to engine performance.
• Side-mounted PTO
The injection system is based on electronically controlled unit injectors that gives low • Exhaust connections
exhaust emissions with good fuel economy and a high torque. The engine can be fit- • Instrument panel
ted with many accessories such as air cleaners, radiators and PTOs in order to suit a • Engine heater
• Stiff rubber engine suspension
variety of installations.
• Air cleaner
• Closed crankcase ventilation
• Studs in flywheel housing
• Low coolant level reaction
• Fine tune potentiometer
Engine speed (rpm) • Ramp start delay
• Ramp up rate
1500 rpm (50 Hz) 1800 rpm (60 Hz)
PRP ESP PRP ESP
Gross power (kW) 226 249 251 276
Gross power (kVA) 253 280 278 309
Spec fuel consumption. Full load (g/kWh) 189 192 197 199
Spec fuel consumption. 3/4 load (g/kWh) 189 188 197 197
Spec fuel consumption. 1/2 load (g/kWh) 196 194 205 202
Heat rejection to coolant (kW) 78 85 86 92

PRP – Prime power: For continuous operation at varying load. Max mean load factor of 70% of ra-
ted power over 24 h of operation. 1 hour/12 hours period of accumulated peak overload to 110%.
ESP – Stand-by power: For operation under normal varying load during a power outage. Not over-
loadable. Max mean load factor of 70% of rated power over 24 h of operation. Not for applications
intended for more than 200 h/year.

This specification may be revised without notice.


SCANIA POWER GENERATION engines

DC09 072A. 226-276 kW (253-309 kVA)


Fuel optimized

Engine description

No of cylinders 5 in-line
Working principle 4-stroke
Firing order 1-2-4-5-3
Displacement 9.3 litres
Bore x stroke 130 x 140 mm
Compression ratio 16:1
Weight 950 kg (excl oil and coolant)
Piston speed at 1500 rpm 7.0 m/s
Piston speed at 1800 rpm 8.4 m/s
Camshaft High position alloy steel
Pistons Aluminium pistons
Connection rods I-section press forgings of alloy steel
Crankshaft Alloy steel with hardened
and polished bearing surfaces
Oil capacity 32-38 dm3
Electrical system 1-pole 24V
1:7000
Edition 03 © Scania CV AB, SE-151 87 Södertälje, Sweden

1242

428 433
855
437

1:7001

All dimensions in mm SE 151 87 Södertälje, Sweden


Telephone +46 8 553 810 00
Telefax +46 8 553 829 93
www.scania.com
[email protected]

You might also like