UEP-HL Stop Cards Feb - 2017
UEP-HL Stop Cards Feb - 2017
UEP-HL Stop Cards Feb - 2017
2 1-Feb-17 TP UEP
4 1-Feb-17 RM UEP
5 1-Feb-17 AD UEP
6 1-Feb-17 FM Hilong
7 1-Feb-17 AD Hilong
8 1-Feb-17 RA Hilong
9 1-Feb-17 DM Hilong
10 1-Feb-17 FM Hilong
11 1-Feb-17 AD Hilong
13 1-Feb-17 FM Hilong
14 1-Feb-17 FM Hilong
15 1-Feb-17 RA Hilong
16 2-Feb-17 TP UEP
18 2-Feb-17 AD UEP
20 2-Feb-17 FM Hilong
21 2-Feb-17 FM Hilong
22 2-Feb-17 FM Hilong
23 2-Feb-17 AD Hilong
24 2-Feb-17 RA Hilong
25 2-Feb-17 DM HILONG
26 2-Feb-17 RA HILONG
27 2-Feb-17 RA HILONG
28 2-Feb-17 FM HILONG
29 2-Feb-17 RA HILONG
37 3-Feb-17 AD Hilong
38 3-Feb-17 TP Hilong
40 3-Feb-17 AD Hilong
41 3-Feb-17 FM Hilong
42 4-Feb-17 TP
50 5-Feb-17 AD UEP
52 5-Feb-17 DM UEP
53 5-Feb-17 DM UEP
55 5-Feb-17 AD UEP
56 5-Feb-17 TP UEP
59 5-Feb-17 AD Hilong
62 5-Feb-17 RA Hilong
63 5-Feb-17 TP Hilong
64 5-Feb-17 TP Hilong
65 5-Feb-17 AD Hilong
66 5-Feb-17 FM Hilong
68 5-Feb-17 AD Hilong
69 5-Feb-17 HSE Hilong
70 5-Feb-17 AD Hilong
74 6-Feb-17 AD UEP
75 6-Feb-17 TP UEP
77 6-Feb-17 AD UEP
81 6-Feb-17 TP UEP
82 6-Feb-17 AD Hilong
84 6-Feb-17 DM Hilong
88 6-Feb-17 TP Hilong
90 6-Feb-17 TP Hilong
93 7-Feb-17 DM UEP
94 7-Feb-17 RA UEP
96 7-Feb-17 DM UEP
98 7-Feb-17 AD UEP
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
S# Category Cards Quantity
Confined Space
1 Entry
0
Cost Saving
2 Opportunity
1
3 Driving Safety 4
4 Dropped Objects 16
5 Energy Isolation 11
Environmental
6 Hazards
7
7 Ground Disturbance 5
8 Health Hazards 10
9 Housekeeping 25
10 HSE Suggestion 8
11 Lifting Operations 6
Management of
12 Change
3
13 Maintenance 36
14 Permit to Work 1
15 PPE 23
Procedures &
16 Orderlines
57
17 Appreciation 20
18 Slip/Trip/Fall 16
19 Tools & Equipment 15
20 Working at Heights 4
21 Manual lifting 0
22 Pinch Point 8
Total 276
Daily SOC / STOP card sheet
When entering the work zone everyone shall be using PPE as required,
PPE Rig Site Closed
observe one FM and inform to use correct PPE while at rig site
Truck helper was standing on the truck while loading equipment with Lifting
Rig Site Closed
forklift, stopped & removed helper from the truck Operations
Work permit was prepared before rigging up the cementing equipment, Procedures &
Rig Site Closed
informed supervisor & they prepared work permit Orderlines
Procedures &
After finishing the work permit should be submit into the HSE office Rig Site Closed
Orderlines
Air winch was not working properly while picking up the elevator,
Maintenance Rig Site Closed
informed mechanic & he fixed it
During cementing job a person was standing near to the high pressure Procedures &
Rig Site Closed
lines, stopped & removed him Orderlines
Observed that the service company person was working near to the v- Dropped
Rig Site Closed
door & at that time v-door was open, stopped him ,close the gate. Objects
After finishing the casing job hole was not covered & a person was doing Procedures &
Rig Site Closed
hammering job near by, I covered the hole properly Orderlines
I was visually inspecting the casing sling time to time for the drop Procedures &
Rig Site Closed
prevention Orderlines
Procedures &
Wind sock on the mud system was not working ,checked & correct it Rig Site Closed
Orderliness
Rubber boots were not placed at proper area, found it & placed at proper
PPE Rig Site Closed
area on the mud tank
Observed that third party person was working without gloves, stopped &
PPE Rig Site Closed
told him to use gloves.
Emergency shower was leaking, inform to the concern & fixed it leakage. Maintenance Rig Site Closed
Observed that third party person was passing from the high pressure Procedures &
Rig Site Closed
area, stopped & briefed him about the hazards, he agreed Orderliness
HSE
Need to maintained good housekeeping standard at all time Rig Site Closed
Suggestion
Third party person was working at height without using fall arrestor, Working at
Rig Site Closed
stopped him & told him the safe system of work. Heights
While lay down DP the RA follow safe body & hand placement good
Appreciation Rig Site Closed
attitude
DP were torqued so driller use manul tong anf FM was in danger zone
Pinch Point Rig Site Closed
so driller tell him to get away to safe place as tong might slip and hit him
Rig floor shower station access was blocked by waste drum so infrom AD
Housekeeping Rig Site Closed
to remove it
Some material in basket was not safely stacked as it can fall out or down
Dropped
whnever its moved so infrom AD and he with fork lift arrange in safe Rig Site Closed
Objects
manner
No stand by person present during work inside confined space so inform Procedures &
Rig Site Closed
TP to check when ever such work is on going Orderlines
Elect. Extension board was left over on Mud tanks after work is finished
Housekeeping Rig Site Closed
which is not good practice
During inspection at Mud tanks found two safety pins of hand railing
Maintenance Rig Site Closed
loose so adjusted them
Welding work shop area was cleaned by welder after cutting and
Housekeeping Rig Site Closed
grinding work good attitude
Chemical drum was placed un safely as it could have rolled on any
Slip/Trip/Fall Rig Site Closed
perosn feet so place it up right
Lifting belt after use was thrown near water tanks which is not good Tools &
Rig Site Closed
practice Equipment
DP stands were made but FM not use rope for handling DP while pick up Procedures &
Rig Site Closed
unsafe act Orderlines
DP protector was thrown from rig floor to ground level which is unsafe act Dropped
Rig Site Closed
so inform AD to rectify and stop any unsafe act Objects
Not using safety galss is becoming a habit so discuss in meeting to
PPE Rig Site Closed
follow hse rules and implemet for self safety
While moving DP from basket to the pipe rack Fork optr. Speed up the
fork due to which the DP got un balance near to fall so infrom fork optr to Driving Safety Rig Site Closed
follow speed limits 5 km/ph
Color code not found on lifting devices informed to TP/AD in meeting for Procedures &
Rig Site Closed
color code marking (BLUE) Orderlines
Water hose after use not closed and water was wasted at pits area so
Procedures &
inform DWM supervisor to check the equipt. Properly after work is Rig Site Closed
Orderlines
finished
Discuss the incident & fatality of person while fuel tank cleaning , refresh HSE
Rig Site Closed
the crew on confnied space entry and follow all procedures in meeting Suggestion
while lifting the HLB unit HLB crew not use tag line and stand near to
Lifting
lifted load so stop work and inform correct and safe procedures and Rig Site Closed
Operations
commenced work again
During FIT job a person by passed high pressure area so HSE stopped
Permit to Work Rig Site Closed
him and inform other route and propely closed the area with caution tape
Halliburton crew after FIT job left over the chicksan line and hoses hap
hazardly then informed them to house keep area to avoid tripping Maintenance Rig Site Closed
hazards
Stabbing board fall arrestor was missed so infrom HSE and he placed a
Appreciation Rig Site Closed
new fall arrestor there
One tube light was damaged in mud lab on tanks infrom Elect for
Maintenance Rig Site Closed
rectification
FM not stand in safe place while driller maked DP connection with
Pinch Point Rig Site Closed
manaul tong so driller stop and makes safe position of FM
Catwalk air winch was rusty and not clean so oiled it and make it
Maintenance Rig Site Closed
lubricated for easy use
While normal drilling the V door gate was not closed by FM and cleaning Procedures &
Rig Site Closed
was continued which is unsafe as drop hazard is present Orderlines
H2s siren fixing plate was loose and can injure any one due to minor cut
Pinch Point Rig Site Closed
if some one passes by so inform Rutledge and he corrected the plate
Left over food and fruits were lying inside dog house which is not a
Health Hazards Rig Site Closed
healthy attitude infrom in pre tour meeting to daily house keep areas
While lowering the elevator FM stand in unsafe position as he can be hit
by the moving links or elevator so inform him to stay safe distance form Pinch Point Rig Site Closed
moving equipt
Material basket gate are broken so infrom TP to repair by welder Maintenance Rig Site Closed
Small size shakcles and bolts were placed in material basket so
Housekeeping Rig Site Closed
collected all and transfer to store room for safe keeping
Drill pipe protector was thrown on the ground from floor which is unsafe Dropped
Rig Site Closed
act must infrmo in meeting to stop such acts Objects
People at camp site not comply with shoes policy so informed in meeting Procedures &
Rig Site Closed
to all to make sure the use of shoes is in compliance Orderlines
While cleaning tanks the stand by person left thye RA inside for tea
Procedures &
break which is not safe practice so discuss with AD & crew to follow PTW Rig Site Closed
Orderlines
requiremnts at all time
Escape line door was broken due to high winds so lifted with air winch to Dropped
Rig Site Open
rig floor and infromed TP to weld it at Rig move Objects
Drill pipe were cleaned and buffed but RA not use face shield which is
PPE Rig Site Closed
unsafe so issued him face shield for work
Mud tank suction line was broken so infrom Mech to repair and he did Slip/Trip/Fall Rig Site Closed
Due to sudden changes in PVT the TP informed in meeting to AD to keep Procedures &
Rig Site Closed
close eye on well and must be ready for well control Orderlines
T cards were fully used by crew so infromed all crew to implement safe Procedures &
Rig Site Closed
practice Orderlines
Management of
Color code changed to BLUE at rig site lifting points by Crew Rig Site Closed
Change
If any worker is near mixing area & while chemical is added so other HSE
Rig Site Closed
person shall take safety and use mask as a protection Suggestion
Grounding cable was not attached so repaired it with tank 5/6 Energy Isolation Rig Site Closed
Emergency slide was blocked as the crew placed material infront of it so Ground
Rig Site Closed
inform the AD to clear any emergency exits and slide for easy use Disturbance
DM got tripped while taking sample at the tanks due to unrolled hose
Slip/Trip/Fall Rig Site Closed
pipes discuss the same in meeting with both shifts to clear walk ways
The wasted food is thrown on floor or table in Rig Mess crew must be
Housekeeping Rig Site Closed
infomred for hygiene and helath issues
Tools &
O2 and Actyl cylinders are seperatly stored Rig Site Closed
Equipment
While pick up slips the FM not pay attention to back safety or manual
Health Hazards Rig Site Closed
handling techniques
Often seen that broken hammers or wrench is used instead of hammer Tools &
Rig Site Closed
which is unsafe practice and inform to all to use correct tools for the job Equipment
AD arrange PTW, tools and Locked out the Pump by Elect. For
Appreciation Rig Site Closed
inspection and repair this is good attitude
Chanin tong was dmaged and I took it to welder for repair and he
Maintenance Rig Site Closed
repaired it for use
TP beofre tour start inform to all to check safety pns and dies of slips Procedures &
Rig Site Closed
and tongs Orderlines
Rig site color code job is finished and now camp lifting points are painted Management of
Rig Site Closed
(BLUE) Change
HSE discuss with crew to follow safety signs, requirements and PPE as
Appreciation Rig Site Closed
they are for our own benefit which motivates all crew
Wash down the driller screen as there were many dirty patches of mud
Housekeeping Rig Site Closed
so after its clean driller can easily see clearly
Electrician performed weekly inspections and closed the minor points on Procedures &
Rig Site Closed
spot like lights changing & loose wiring Orderlines
Discuss the importance of PPE specially eye protetcion with crew and
PPE Rig Site Closed
focused them to use at work areas
Discuss with crew that during POOH always be carefull for DP screen Dropped
Rig Site Closed
when DM removes it, may be it can drop and hit the floor Objects
Rotary tabl water passing ditches were cleaned by FM so easliy the
Housekeeping Rig Site Closed
water can pass from floor to pits
Safety life line needs to be installed at A frame as FM go for cleaning job HSE
Rig Site Closed
they use it Suggestion
Informed the crew in meeting that never enter near the crane working
Lifting
radius around 360 degree as its danger zone except for rigger and Rig Site Closed
Operations
signalman when they feel its safe working in that position
Found lifting belts damaged so sent to welder to cut off and diospose Tools &
Rig Site Closed
them as they are unsafe for use Equipment
Observed that oil lubricator pump shut off and not start so inform
Maintenance Rig Site Closed
electrcian and he rectified
Cleaned the drill spool and cover it with plastic to save from water and
Maintenance Rig Site Closed
rust
Power tong oil was leaking so infrom Mech to check and repair and he
Maintenance Rig Site Closed
did in time
T cards were not followed strictly by the crew discuss in meeting for Procedures &
Rig Site Closed
complete compliance Orderlines
After mixing chemical the RA thorweed away the bag on ground which is
Housekeeping Rig Site Closed
not good practice so tell him to collect and dispose in bin
Diesel and oil was used for lubrication of DP but the FM not use rubber
Health Hazards Rig Site Closed
gloves which might damage the skin discussed with them for safety
Pump area was baricated as they are running on high pressure so its not Procedures &
Rig Site Closed
safe working or crossing at that area Orderlines
FM standing upside on Drill pipes on racks for cleaning its unsafe as he
Slip/Trip/Fall Rig Site Closed
might get slip
Inspected the slings on ware house and inform material man to cover the Tools &
Rig Site Closed
sings from plastic to save from dust and weather Equipment
AtaUllah performs duty on shaker with full PPE and handles the system
Appreciation Rig Site Closed
well good skills and hard work
Procedures &
New safety signs are posted across the site for more safety awareness Rig Site Closed
Orderlines
Some bags of chemicals were torn and spilled at chemical area so Environmental
Rig Site Closed
infrom Mud engrr to make sure chemical is cleaned Hazards
First aid box at mud tank was mepty so informed DR to check and refill Health Hazards Rig Site Closed
Handrailing to rig floor ladders was loose nifomred Mech to check and fix Tools &
Rig Site Closed
after Mech tighten the bolts and now ok Equipment
Mud Pump area is barricated to identify high pressure area and danger
Procedures &
zone so all crew is instructed not to go in that area during pump Rig Site Closed
Orderlines
opertaion
Crane optr. Helps and works with drilling crew its good team work from
Appreciation Rig Site Closed
him
Chemiclas were not covered so inform the Mud Engg to cover the Environmental
Rig Site Closed
chemicals from sun light and weather Hazards
Speed limit sign board was posted at the rig site for speed control and
Driving Safety Rig Site Closed
identification
Tool pusher daily assigns job to all crew and check at shift end its good Management of
Rig Site Closed
safety leader ship Change
Water gun was leaking so infrom to Mech to repair as it might get
Energy Isolation Rig Site Closed
damage or person can get electrical shock
Power ting and manual tongs were color coded for safe handling points Maintenance Rig Site Closed
Informed to Plumbing supervisor for water iisue in camp during day and
Maintenance Camp Open
night shifts time so check and rectify
SWL was painted on the air winches at rig floor by FM Appreciation Rig Site Closed
Manual tong handle was repaired as it got broke in rig move time now
Maintenance Rig Site Closed
safley welded and can be used
Pipe stopper was missing on casing racks so instructed welder to make Procedures &
Rig Site Closed
a new pipe stopper & inform crew not to use stopper for any other work Orderlines
When making connection the DP elevator was not jamming and not Tools &
Rig Site Closed
easliy operated by DM so inform Mech to lubricate & check Equipment
Lifting
Rig site all lifitng points of equipments , loads were color coded BLUE Rig Site Closed
Operations
Shakerman was given H2S detector by rutledge for use at shaker PPE Rig Site Closed
Water hoses at tanks were causing tripping hazard so inform crew that
Slip/Trip/Fall Rig Site Closed
when evr shift is over must give clean & clear work are to other shift
STOP card box on rig floor was filled with oily rags & gloves so cleaned it Procedures &
Rig Site Closed
and keep at dog house Orderlines
During rig inspection found dried grounding pits so infromed Elect. To
Maintenance Rig Site Closed
check and water tehm daily
One high pressure line was leaked so quickly arranged new hose and
Maintenance Rig Site Closed
installed it was good team effort
While pressure test service co. person by pass barricaded area which is Procedures &
Rig Site Closed
unsafe act infrom him to follow HSE signs for his safety Orderlines
While lifting kelly kock with Fork lift the lifting belt got tangled and the
Dropped
equipt. Got un balance no body was near by so fork optr slowly lowered Rig Site Closed
Objects
kelly kock and released it
AC of junior side rooms in camp not cooling so infrom Elect. To check
Maintenance Rig Site Open
and repair
While playing in camp side the ball go outside the fence in night & a
Procedures &
person opened the fence and took the ball back inside camp which is Rig Site Closed
Orderlines
unsafe for security purpose inform to security perosnnel
Smoke detector in general washroom is not working please check Maintenance Rig Site Closed
All 5" DP were cleaned and lubricated and kept in baskets good team
Appreciation Rig Site Closed
effort by day shift
Minor oil patches near drill pipe baskets so infrm AD to clean with dry Environmental
Rig Site Closed
sand Hazards
DWM unit is not properly lighted so inform the electrician to arrange one Procedures &
Rig Site Closed
light nearn their unit Orderlines
Procedures &
Smoking policy & drug policy discussed with crew for refresher Rig Site Closed
Orderlines
Observed that tools was left unattended and not placed properly. Discuss
Housekeeping Rig Site Closed
with the concern and placed at proper area.
Poor Housekeeping notice at mixing area ,discuss with the concern and
Housekeeping Rig Site Closed
clean that area.
Poor housekeeping observed in the workshop area, discuss with the
Housekeeping Rig Site Closed
concern & fixed this issue.
Observed that the person was standing at high noise area, instruct him
Health Hazards Rig Site Closed
to use ear plugs or removed from that area.
Procedures &
Color code was missed from the shackles, paint it accordingly. Rig Site Closed
Orderlines
Water connection to vacuum degasser was missed, arranged the hose
Maintenance Rig Site Closed
and made a proper connection.
One person was walking on the augers, stopped him and told him about
Slip/Trip/Fall Rig Site Closed
the hazards.
Power tong safety pin was missed ,installed it correctly. Maintenance Rig Site Closed
Fire extinguisher was not placed after completing the task, contact the Procedures &
Rig Site Closed
supervisor & remind him about the procedure. Orderlines
Handover is a very good safety tool to know about the last 12 hrs HSE
Rig Site Closed
worked. Suggestion
During lifting chemical drum, not properly latch it ,stopped the crane Lifting
Rig Site Closed
operator & rearrange the job after corrective actions Operations
There was too much water between the mud pumps, cleaned it properly Housekeeping Rig Site Closed
Site safety induction was given to SLB wire line crew and informed to Procedures &
Rig Site Closed
follow all safety requirements during the job Orderlines
While Rig up the SLB tools one SLB crew not used gloves so SLB
supervisor stop him and informed to use proper PPE for the job its good PPE Rig Site Closed
safety leader ship
while maintenance of pumps the FM not using proper tools he used
Tools &
broken hammer so stoop him and infrom to take new hammer from store Rig Site Closed
Equipment
for work
Fire pump room was not cleaned, oil and water present informed Mech
Housekeeping Rig Site Closed
to clean and daily check the status of pump operation
While off loading fuel the truck driver not use ppe and did not connected
the grounding cable so the labor stop them and infrom to use ppe and Energy Isolation Rig Site Closed
connected bonding cable before offloading starts
Camp site junior mess door was welded as ig got broken due to rough
Maintenance Rig Site Closed
use now ok
Oxygen & Acetylene cylinders were not upright & chained while welding
Procedures &
operation near work shop so inform the welder for correct procedure to Rig Site Closed
Orderlines
keep separate both cylinders
T cards were made up to date & informed crew to properly use T cards Procedures &
Rig Site Closed
for safety Orderlines
DWM crew not perform LOTO on uager and working on auger so
Energy Isolation Rig Site Closed
stopped them and told safe procedure for LOTO and then start work
During cut & slip drill line RA stand near cat walk which is unsafe place Dropped
Rig Site Closed
so indtrcuted to move back and keep eye on any dropped line or tool Objects
Pressure tets on BOP but service co. person come and observe
Pinch Point Rig Site Closed
operation in unsafe place so instrcut to move out
During work at height at BOP the FM not use safety harness so stop Working at
Rig Site Closed
them and give verbal warning for not following safety procedures Heights
Jar was laid down from rig floor but one RA near the catw alk so FM told Dropped
Rig Site Closed
him to keep back due tot drop hazard Objects
No rope used on hammer wrench while BOP job so inform crew to use
Pinch Point Rig Site Closed
safe tools for operation and avoid pinch points
Eye wash was laeking at shaker area inform HSE and thewn we refilled it Maintenance Rig Site Closed
Broken hammers were palced in work shop to install new handles for Tools &
Rig Site Closed
safe work by FM Equipment
Safety galsses were not used while cleaning the shaker area so told the
PPE Rig Site Closed
RA hazards for human eye and msut compliy safety rules
Observed 54 room wash room and exhaust fan not working informm C
Maintenance Rig Site Closed
Boss to rectify
Appreciation for DM and crew who carried out safe procedures during
Appreciation Rig Site Closed
the well operation
Area was barricaded when SLB job was on going so all crew followed it
Appreciation Rig Site Closed
as procedure
While rig down SLB tools the SLB crew stand on cat walk so it was Dropped
Rig Site Closed
unsafe so SLB supervisor instruct their crew to move out Objects
Fork lift was off loading the equipt. Truck helper was near the drop zone Dropped
Rig Site Closed
& in unsafe area so told them to keep away Objects
Halliburton guy while working on the cement unit but not hook up safety Working at
Rig Site Closed
harness so infrom him to use safety equipt. Properly Heights
Observe that third party crew not use gloves and eye protection while
PPE Rig Site Closed
working
While cleaning the chemical area the labor not use face mask which can
Health Hazards Rig Site Closed
cause health problems so infrom them to use proper PPE
Service co. person by mistak came outside of unit and started to go
towards mud tanks without hard hat so stopped him and inform that no PPE Rig Site Closed
PPE and he thanked
Barrication not done during the SLB wire line job so I barricaded the area Procedures &
Rig Site Closed
for safety awareness Orderlines
SLB crew standing on the cat walk while pick up tools from cat walk so Dropped
Rig Site Closed
stop them and told to stand away Objects
SLB crew perosn not use eye protetcion and working at rig floor so inform him for
saefty procedures and he followed
PPE Rig Site Closed
AC was placed on electrical cable tray which can damage the cables inside Procedures &
inform Mech to remove it and place other place
Rig Site Closed
Orderlines
Hose pipe was not rolled after cleaning job so inform the FM to roll back
Slip/Trip/Fall Rig Site Closed
hose pipe and clear area
Helper with the welder was not using safety galsses as he is also
PPE Rig Site Closed
exposed to hazardous welding light so inform him to use goggles
BOP area after POOH was slippery so AD instructed the RA to clean
Slip/Trip/Fall Rig Site Closed
area
Mud pumps and tanks were cleaned by RA and it was a good effort Appreciation Rig Site Closed
Rutledge H2S Engg. Trained all guys for safe SCBA donning and ERP Procedures &
Rig Site Closed
proceudre in emergency Orderlines
Used gloves were found at mud tanks,tool box and walk ways enforced
Housekeeping Rig Site Closed
the crew to throw waste in proper bins
Auger near the waste pit was un balance inform DWM crew to check and
Maintenance Rig Site Closed
rectify
Gas detetcor was not usd by RA at trip tank & shaker area so give him Procedures &
Rig Site Closed
h2s detector for safety Orderlines
Safety meeting was held by SLB before TLC job and all possible safety Procedures &
Rig Site Closed
measure and operational condition were discussed Orderlines
Welding cable is damaged and unsafe for use so inform to TP/RM for
Procedures &
new cable and they confirmed that new cable is ordered and will arrive Rig Site Closed
Orderlines
soon
Welding work shop was a mess during inspection no house keeping ,
cables un rolled, tools not in tool box so infrom welder to make good Housekeeping Rig Site Closed
cleaning and maintain work shop
During site visit found a thinner liquid bottle near baskets after paint job Procedures &
Rig Site Closed
left there Orderlines
Eye wash lids are leaking infrom materialman to order new pairs as lids
PPE Rig Site Closed
are not available on rig site
SLB crew make too much mess, empty water bottles, tissues, cloth
pieces are present around there unit infrom SLB crew to clean the area Housekeeping Rig Site Closed
when job is finished
Electrician was inspecting the lights at rig floor but not follow safety rules
with out LOTO or isolation insoection of electrical equipment is not Energy Isolation Rig Site Closed
allowed
General wash room door is not working inform to camp supervisor to
Maintenance Rig Site Closed
check and repair
All crew come to work in welding work shop but after wards leave the
Housekeeping Rig Site Closed
area with out cleaning which is not a good habitt
While cut the drill line area was cordon off and supervised so no un Procedures &
Rig Site Closed
authorized person is exposed to unsa fe condition Orderlines
While cleaning the agitator motor crew not power off the motor its unsafe
Energy Isolation Rig Site Closed
as rotating equipt. Can cause damage to person if trapped
After oil seal change of the agitator the spill over oil was not cleaned by
the Mech and he left his work area discuss in meeting to clean area after Slip/Trip/Fall Rig Site Closed
work
BOP grating was loose and unbalance so with help of AD I arraneg it in Ground
Rig Site Closed
safe manner Disturbance
Always inform the shifts to control the work place slip & trip hazards Slip/Trip/Fall Rig Site Closed
Tool box at rig floor was dirty from inside so inform the crew to clean it up
Housekeeping Rig Site Closed
and throw the trash in proper bins
Gloves after use are often thrown on the work area or walk ways which is
not safe pracrice so informed the crew to motivate each other for a Housekeeping Rig Site Closed
cleaner work place
Eyes are important part of the body so every time I discuss with crew for
PPE Rig Site Closed
eye protection when working at rig site
Halliburton cementing crew using mobile phone near well head which is
Procedures &
unsafe so inform him the safe procedure and area for use of electrcial Rig Site Closed
Orderlines
devices
Safety harness was thrown on the rig floor after using at monkey baord Procedures &
Rig Site Closed
so instrcut all crew to take care of safety items Orderlines
Mud engg appreciated all the crew for safely completing the well with
Appreciation Rig Site Closed
safe procedures followed
Room no 54/56 AC problem waas rectified by electrciuan in time Maintenance Rig Site Closed
Inform the crew to check all hammers for mushrom head before rig move Tools &
Rig Site Closed
and repair all tools needed during rig move Equipment
Friut & food items thrown inside the dog house creating a bad odour and
un healthy condition so its informed to crew to mujst check rest rooms Health Hazards Rig Site Closed
are clean
Rajani-7 February-17
Target
Remarks
Date
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA Discuss in pre tour meeting
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA Discuss in pre tour meeting
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA Discuss in pre tour meeting
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA Discuss in pre tour meeting
NA
NA
NA
NA
NA
NA
NA
NA
NA
Service co. person by mistak came outside of unit and started to go towards
### AD UEP mud tanks without hard hat so stopped him and inform that no PPE and he
thanked
Barrication not done during the SLB wire line job so I barricaded the area for
### DM UEP
safety awareness
SLB crew standing on the cat walk while pick up tools from cat walk so stop
### DM UEP
them and told to stand away
SLB crew perosn not use eye protetcion and working at rig floor so inform him for saefty
### AD UEP procedures and he followed
AC was placed on electrical cable tray which can damage the cables inside inform
### ELECT UEP Mech to remove it and place other place
Hose pipe was not rolled after cleaning job so inform the FM to roll back hose
### TP UEP
pipe and clear area
Helper with the welder was not using safety galsses as he is also exposed to
### FM Hilong
hazardous welding light so inform him to use goggles
### FM Hilong BOP area after POOH was slippery so AD instructed the RA to clean area
### AD Hilong Mud pumps and tanks were cleaned by RA and it was a good effort
Rutledge H2S Engg. Trained all guys for safe SCBA donning and ERP
### HSE Hilong
proceudre in emergency
Used gloves were found at mud tanks,tool box and walk ways enforced the
### HSE Hilong
crew to throw waste in proper bins
Auger near the waste pit was un balance inform DWM crew to check and
### FM Hilong
rectify
Gas detetcor was not usd by RA at trip tank & shaker area so give him h2s
### TP Hilong
detector for safety
Safety meeting was held by SLB before TLC job and all possible safety
### HSE Hilong
measure and operational condition were discussed
Welding cable is damaged and unsafe for use so inform to TP/RM for new
### TP Hilong
cable and they confirmed that new cable is ordered and will arrive soon
Welding work shop was a mess during inspection no house keeping , cables
### HSE Hilong un rolled, tools not in tool box so infrom welder to make good cleaning and
maintain work shop
During site visit found a thinner liquid bottle near baskets after paint job left
### HSE Hilong
there
Eye wash lids are leaking infrom materialman to order new pairs as lids are not
### HSE Hilong
available on rig site
SLB crew make too much mess, empty water bottles, tissues, cloth pieces are
### AD Hilong present around there unit infrom SLB crew to clean the area when job is
finished
2 PTW cold ( TLC SLB / Repair Agitator 16 ) Drop inspect / soc = 7 - stp
13=20
Health Hazards Rig Site Closed
Procedures &
Rig Site Closed
Orderlines
Dropped
Rig Site Closed
Objects
Procedures &
Rig Site Closed
Orderlines
Procedures &
Rig Site Closed
Orderlines
Procedures &
Rig Site Closed
Orderlines
Procedures &
Rig Site Closed
Orderlines
Procedures &
Rig Site Closed
Orderlines
Maintenance
Maintenance
Appreciation
Maintenance
Procedures &
Orderlines
Tools &
Equipment
Lifting
Operations
PPE
Slip/Trip/Fall
Procedures &
Orderlines
Dropped
Objects
Housekeeping
Housekeeping
Environmental
Hazards
Driving Safety
Energy Isolation
Dropped
Objects
Health Hazards
Energy Isolation
Slip/Trip/Fall
Procedures &
Orderlines
Maintenance
Maintenance
Procedures &
Orderlines
Dropped
Objects
Maintenance
Procedures &
Orderlines
Maintenance
Appreciation
Environmental
Hazards
Procedures &
Orderlines
Procedures &
Orderlines
Housekeeping
Housekeeping
Housekeeping
Health Hazards
Procedures &
Orderlines
Maintenance
Slip/Trip/Fall
Maintenance
Procedures &
Orderlines
HSE Suggestion
Lifting
Operations
Housekeeping
Procedures &
Orderlines
PPE
Tools &
Equipment
Housekeeping
Energy Isolation
Maintenance
Procedures &
Orderlines
Procedures &
Orderlines
Energy Isolation
Dropped
Objects
Pinch Point
Working at
Heights
Dropped
Objects
Pinch Point
Maintenance
Tools &
Equipment
PPE
Maintenance
Appreciation
Appreciation
Dropped
Objects
Dropped
Objects
Working at
Heights
PPE
Health Hazards
PPE
Procedures &
Orderlines
Dropped
Objects
PPE
Procedures &
Orderlines
Slip/Trip/Fall
PPE
Slip/Trip/Fall
Appreciation
Procedures &
Orderlines
Housekeeping
Maintenance
Procedures &
Orderlines
Procedures &
Orderlines
Procedures &
Orderlines
Housekeeping
Procedures &
Orderlines
PPE
Housekeeping
1 UNSAFE ACT 不安全行为 256
2 SAFE ACT安全行为 20
7.25%
92.75%
92.75%
Ground Disturbance 5;
1.81%
Ground Disturbance 5;
1.81%
ng Opportuni ty 1 Driving Safety 4 Dropped Objects 16 Energy Is olation 11 Envi ronmental Haza rds 7
azards 10 Hous ekeepi ng 25 HSE Suggestion 8 Li fting Operations 6 Ma nagement of Change 3
Work 1 PPE 23 Procedures & Orderl i nes 57 Appreciation 20 Sl i p/Tri p/Fal l 16
at Hei ghts 4 Ma nual li fti ng 0 Pi nch Poi nt 8
3