4 Pow-R-Line Group-Mounted Distribution Switchboard
Description Page
4 Pow-R-Line Distribution Switchboards
Product Description . . . . . . . . . . . . . . . . . . . . V2-T4-2
4 Application Description . . . . . . . . . . . . . . . . . . V2-T4-2
Features, Benefits and Functions . . . . . . . . . . V2-T4-2
4 Standards and Certifications . . . . . . . . . . . . . . V2-T4-2
Product Selection . . . . . . . . . . . . . . . . . . . . . . V2-T4-2
4
4
4
4
4
4
4 Pow-R-Line Distribution Switchboards
4 Product Description Features, Benefits Standards and Certifications
Eatons Pow-R-Line and Functions Meets NEMA Standard
4 distribution switchboards 6000A maximum main Main and Individually
Mounted Devices
PB-2 and UL 891
combine a space-saving bus rating Seismically qualified
4 Magnum SB insulated
design with modular 600 Vac and below
construction and increased case circuit breakers, 800
600 Vdc and below 5000A, fixed or drawout
4 system ratings to provide
economical and dependable Front or rear accessible Magnum DS power circuit
electrical system distribution Type 1 or Type 3R breakers, 8005000A,
4 and protection. enclosures fixed or drawout Product Selection
ANSI-61 gray powder Series NRX insulated For complete application and
4 Application Description
Refer to Eatons Consulting
coat paint finish circuit breaker, 4003000A, pricing information, contact
Microprocessor-based fixed or drawout your local Eaton sales office.
4 Application Guide. metering and monitoring Molded case circuit
devices breakers, 4002500A,
4 Utility metering provisions fixed mounted
Surge protective devices Bolted pressure switches,
4 (SPD) 8005000A
Ground fault protection FDPW fusible switches,
4 on mains and distribution
devices
4001200A
Group-Mounted
4 Busway and transformer
connections
Distribution Devices
Molded case circuit
4 Complete protective device
accessory capability
breakers, 151200A
FDPW fusible switches,
4 65 kAIC bus bracing
standard; optional 100
301200A
or 200 kAIC
4 Standard tin-plated
aluminum bus; optional
4 copper- or silver-plated
copper bus
4 Standard bus ampacities
based on UL heat test
4 ratings. Optional density
rated bus systems are
4 also available
4
V2-T4-2 Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com
Switchboards
Group-Mounted Switchboards
4.1
Contents
Commercial Metering Switchboards
Description Page
4
Commercial Metering Switchboards 4
Features, Benefits and Functions . . . . . . . . . . . V2-T4-4
Standards and Certifications . . . . . . . . . . . . . . V2-T4-5 4
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V2-T4-5
Technical Data and Specifications . . . . . . . . . . V2-T4-5 4
4
4
WWCMS WCMS
4
4
4
4
Commercial Metering Switchboards 4
Product Description Application Description 4
Eatons commercial metering
switchboards provide Type WWCMS Type WCMS 4
electrical system distribution For EUSERC serviced areas. For other than EUSERC
and metering for shopping
centers, office buildings
The self-contained meter
sockets include a test
serviced areas. Self-contained
meter sockets are provided
4
bypass/disconnect block per with manual lever bypass and
and other commercial
multimetering applications. EUSERC requirements, and can be arranged for either hot 4
are arranged, typically, for hot or cold sequence metering.
Using standard Pow-R-Line
construction and features,
sequence metering. 4
these switchboards
incorporate metering sections 4
with tenant feeder circuits
using meter sockets to meet 4
local utility or customer
requirements. 4
All meter sockets and
associated feeder devices are 4
completely factory prewired
and shipped ready for the
Socket with Manual Lever Bypass
4
installation of the meters.
Refer to Eatons Consulting
Application Guide.
4
Socket and Test Block Assembly
4
4
4
4
4
4
4
4
Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com V2-T4-3
4.1 Switchboards
Group-Mounted Switchboards
Seismically qualified
4
4
Product Selection
For complete application and
4
pricing information, contact
your local Eaton sales office. 4
Technical Data and Specifications 4
Service Metering Sections 4
120/240V, single-phase, Tenant main disconnects
three-wire and meter sockets (200A
maximum self-contained
4
240/120V, 208Y/120V,
415Y/240V, 480Y/277V or
600Y/347V three-phase,
metered circuits)
Hot sequence
4
four-wire
600 Vdc
metering circuits
Cold sequence metering
4
Main Bus Rating
circuits (WCMS only)
Optional rear barriered
4
4004000A
4
Contents
4 Integrated Facility Switchboard
Description Page
4 Integrated Facility Switchboards
Features, Benefits and Functions . . . . . . . . . . V2-T4-7
4 Standards and Certifications . . . . . . . . . . . . . . V2-T4-7
Product Selection. . . . . . . . . . . . . . . . . . . . . . . V2-T4-7
4 An Eaton
Green Solution
4
4
4
4
4
4
4 Product Description Application Description
4 Eatons Integrated Facility
Switchboards use the
The service entrance
equipment can be integrated
Other associated equipment
can also be integrated into
Eatons Integrated Facility
Switchboards are designed
modular Pow-R-Line group- with multiple lighting the assembly, including to meet specific needs for:
4 mounted switchboard design and appliance branch dry-type distribution
to integrate traditionally panelboards into a compact transformers, Building
Retail chain stores
4 separate electrical distribution front-accessible group- Management Systems, Commercial offices
and control equipment into a mounted switchboard. Where Pow-R-Command lighting High rise buildings
4 single space-saving factory
assembled and connected
multiple panelboards are
used in the same electrical
control system, electronic
controls, surge protective
Correctional facilities
Agricultural facilities
4 package. room as a conventional
distribution switchboard or
devices, metering and
energy monitoring devices.
Industrial facilities
power panelboards, the Depending upon the Hospitals/healthcare
4 integrated design will application, other user- facilities
significantly reduce defined equipment such as Educational facilities
4 equipment space a subsystem control package
Whether the application is a
requirements, as well as may also be incorporated.
4 reduce installation time
and costs.
multi-site prototype or single
application, integrated
switchboards offer time and
4 space-saving features.
storage, cubicle
4
Healthcareadditional
work area
Retrofitsability to fit
4
existing rooms
4
4
4
4
4
4
4
Traditionally Mounted Equipment
4
4
4
4
4
4
4
4
Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com V2-T4-7
4.3 Switchboards
Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards
Contents
4 Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards
Description Page
4 Pow-R-Line Drawout Molded Case Circuit Breaker
Switchboards
4 Product Selection . . . . . . . . . . . . . . . . . . . . . . . V2-T4-9
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V2-T4-10
4 Options, Accessories and Modifications. . . . . . V2-T4-13
4
4
4
4
4
4
4 Product Description Features, Benefits and Standards and
Functions Certifications
4 Drawout molded case
circuit breaker switchboard Eatons Pow-R-Line Drawout Aluminum bus is standard UL 891 listed
4 Front accessible switchboard design is listed with copper and silver-plated
4
70250 200 100 35 JGC 7X
250600 85 35 18 LGS 9X
4
250600 100 65 35 LGH 9X
Dual Branch/Feeder 250600 200 100 50 LGC 9X
Single-Mount Breakers with Electronic 310+ Trip Units (Three-Pole Only)
2050 85 35 18 JGS 7X
4
2050
2050
100
200
65
100
25
35
JGH
JGC
7X
7X
4
40100 85 35 18 JGS 7X
4
40100 100 65 25 JGH 7X
40100 200 100 35 JGC 7X 4
80150 85 35 18 JGS 7X
80150 100 65 25 JGH 7X 4
80150 200 100 35 JGC 7X
100250 85 35 18 JGS 7X 4
100250 100 65 25 JGH 7X
100250 200 100 35 JGC 7X 4
100250 85 35 18 LGS 9X
100250 100 65 35 LGH 9X 4
100250 200 100 50 LGC 9X
200400 85 35 18 LGS 9X 4
200400 100 65 35 LGH 9X
200400 200 100 50 LGC 9X 4
4
250600 85 35 18 LGS 9X
250600 100 65 35 LGH 9X
250600 200
Single-Mount 310+ Electronic Trip Unit
100 50 LGC 9X
4
5001200 85 50 25 NGS 12X
4
5001200 100 65 35 NGH 12X
5001200 200 100 65 NGC 12X 4
Provision for Future (Includes Factory-Installed Base Cassette)
20250 Any JG family branch/feeder breaker 7X 4
100600 Any LG family branch/feeder breaker 9X
4
4
4
4
4
Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com V2-T4-9
4.3 Switchboards
Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards
Dimensions
4 Approximate Dimensions in Inches (mm)
4 Select the appropriate All breakers are front
distribution section(s) for accessible and front
4 drawout MCCB feeder
devices from the sections
connected.
4 shown below.
4
4 Optional
Customer
Metering
4 50X
Vertical
50X
Vertical 1200A
Feeder 90.00
or
Blank
90.00 90.00 Max.
Panel Panel
4
(2286.0) (2286.0) (2286.0)
Space Space Optional GFP
for for
Optional GFP
Devices Devices
4 22X 22X
Dist. Device
Space
Classis
4
4 36.00 24.00 24.00
18.00 18.00
36, 45 51.00 (914.4) (609.6) 36, 45 D
(914.4, 1143.0) (457.2) (1295.4) (457.2) (914.4, 1143.0) (609.6)
Min. Min. W
4 JG/LG Full
Distribution Section
NG Full
Distribution Section
Top-Mounted Feeder
with Distribution Chassis
Maximum 2000A
CT Compartment
4
Combination Section
Notes
4 All four sections widths 36-inch minimum.
See distribution layout Guides Page V2-T4-11 for actual minimum structure width and for feeder device X requirements.
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
V2-T4-10 Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com
Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards
Switchboards
4.3
Layout for Group-Mounted Drawout Molded Case Circuit Breaker Feeder Devices
4
Instructions
Determine the structure width by the group-mounted drawout MCCB feeder devices below. 4
The width of the structure is determined by the maximum structure size shown for each device.
4
Surge Protective Device 4
7X (includes behind the
Surge Protective
Device (SPD) 1
or
10X
deadfront disconnect)
7X through 200 kA
4
10X 250 kA through 400 kA
4
4
4
Customer
4
11X Customer Metering
Metering
4
4
36-Inch (914.4 mm) Wide Minimum Structure
2 or 3P 250A
Single Drawout
Feeder
7X
Max.
JGS, JGH, JGC
4
4
2 or 3P
600A
4
Single Drawout 9X LGS, LGH, LGC
Feeder
Max.
4
4
45-Inch (1143.0 mm)
4
Wide Structure
2 or 3P 2 or 3P
Dual Drawout 250A JGS, JGH, JGC
Dual Drawout 7X
Max.
Feeder Feeder
4
4
51-Inch (1295.4 mm)
3P 3P
Dual Drawout Dual Drawout 600A 4
Wide Structure
4
4
Note
1 Preferred location of SPD is mounted at the top of the first distribution section.
4
4
4
4
4
4
4
4
Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com V2-T4-11
4.3 Switchboards
Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards
4
4
4 2 or 3P
800A
4
Single Drawout 12X NGS, NGH, NGC
Max.
Feeder
4
51-Inch (1295.4 mm) Wide Minimum Structure
4
4
2 or 3P
4 Single Drawout 12X
1200A
Max.
NGS, NGH, NGC
Feeder
4
4
4 Note
1 Preferred location of SPD is mounted at the top of the first distribution section.
4
4
4
4
4
4
4
4
4
4
V2-T4-12 Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com
Switchboards
Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards
4.3
Options, Accessories and Modifications 6. Copper Main Busbars 8. Electronic Trip Units
Optional copper busbars are Thermal-magnetic trip units 4
1. Ambient Compensating available in all ampere ratings. are standard. For electronic
Breakers trip units, select appropriate 4
For ambient compensating Modification 6 breaker from the electronic
breakers (where available) in Ampere Bare Copper Silver-Plated trip section of Pages 4
lieu of standard breakers, add Range Chassis Bus Copper Bus V2-T4-9 and V2-T4-11. See
10% to panelboard branch
breaker and to main breaker 800
selection below for electronic
trip units.
4
list prices, when required. 1200
Panels with this option can 1600 Modification 8
4
not be UL listed.
2000 Breaker Frame
Family Trip Unit Type
4
2500
2. JG and LG Breaker AccessoriesInternal (Only One Accessory
Per Position) 3000 Drawout Feeder Digitrip 310+ LS
JGS, JGH, JGC Digitrip 310+ LSI 4
4000
Accessories Digitrip 310+ LSG
4
Breaker Device 7. Density Rated Bus Digitrip 310+ LSIG
Type Mounting Internal Breaker Accessory
Standard main bus ampere LGS, LGH, LGC
Drawout
310+ LS 4
JG family Drawout 1 Auxiliary switch 1A-1B rating is determined by UL 310+ LSI
JG family Drawout 1 Auxiliary switch 2A-2B listed temperature rise
testing. Density rated bus is
310+ LSG 4
JG family Drawout 1 Bell alarm 310+ LSIG
JG family Drawout 1 High load alarm w/trip
defined at 750A per square
inch for aluminum bus and 310+ w/GFA LSA 4
1000A per square inch for 310+ w/GFA LSIA
4
JG family Drawout 1 Ground fault alarm w/trip
copper bus. Adder for 310+ w/Arcflash ALSI
JG family Drawout 2 Undervoltage release
aluminum density rated bus is 310+ w/Arcflash ALSIG
JG family Drawout 2 Zone selective interlock in addition to the base price. 310+ w/ZSI LSI 4
LG family Drawout 1 Auxiliary switch 1A-1B Adder for copper density
310+ w/ZSI LSIG
LG family Drawout 1 Auxiliary switch 2A-2B
rated bus is in addition to
the base price plus the 310+ w/ZSI, 4
LG family Drawout 1 Bell alarm Arcflash ALSI
appropriate adder for copper
LG family Drawout 1 High load alarm w/trip bus. See Modification 7. 310+ w/ZSI, 4
Arcflash ALSIG
4
LG family Drawout 1 Ground fault alarm w/trip
NG Drawout 310+ LS
LG family Drawout 2 Undervoltage release 3
Modification 7
310+ LSI
4
Ampere Rating
LG family Drawout 2 Zone selective interlock 310+ LSG
Aluminum750A per Square Inch 310+ LSIG
Notes
1 Accessories wired to a pull-apart terminal block. Right position only. 800 310+ w/GFA LSA 4
2 Accessories wired to a pull-apart terminal block. Left position only.
310+ w/GFA LSIA
4
3 Not available when breaker is equipped with ARMS trip unit.
1200
310+ w/Arcflash ALSI
1600
310+ w/Arcflash ALSIG
3. Drawout NG Breaker
Accessories Internal
4. Compression Main Lugs
Al/Cu Burndy Range Taking
2000 310+ w/ZSI LSI 4
Type. 2500 310+ w/ZSI LSIG
Accessories
3000 310+ w/ZSI, 4
Internal NG Breaker Accessories Modification 4 Arcflash ALSI
Drawout 1 Auxiliary switch 1A-1B Main Lug PRL4D Lug 4000 310+ w/ZSI, 4
Amperes Wire Range Arcflash ALSIG
4
Drawout 1 Auxiliary switch 2A-2B Copper1000A per Square Inch
800 (3) 500750 kcmil Notes
Drawout 1 Bell alarm 800
L = Adjustable long time pickup
4
1200 (4) #2600 kcmil
Drawout 1 High load alarm with trip 1200
(4) 500750 kcmil S = Adjustable short time pickup
Drawout 1 Ground fault alarm with trip w/fixed short time delay
1600
Drawout 2 Undervoltage release 3 5. Copper Lugs/Terminals
2000
I
G
= Adjustable instantaneous pickup
= Adjustable ground fault pickup
4
Drawout 2 Zone selective interlock Optional copper mechanical
main lugs only and includes 2500
A = Adjustable ground fault alarm
only (no trip) 4
main incoming neutral lug. 3000 Arcflash = Arcflash Reduction
4 Note
1 Available on only single-mounted
4
drawout. Not available on dual-mounted
feeder devices.
4
4
4
4
4
4
4
4
4
4
4
4
V2-T4-14 Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com
Switchboards
Compartmentalized Switchboards
4.4
Contents
Compartmentalized Feeder Sections
Description Page
4
Compartmentalized Switchboards 4
Standards and Certifications . . . . . . . . . . . . . . V2-T4-16
4
4
4
4
4
4
Front ViewCircuit Breakers Front ViewFusible Units
4
4
Product Description Features, Benefits and Functions 4
Eatons Pow-R-Line i
switchboards are engineered
Significant safety features
include:
Main devices are available
from 4004000A and can
Integrated Monitoring
Protection and Control
4
in a new compartmentalized include molded case circuit
design for applications where
Individual compartments breakers, Magnum SB,
Communications Systems
The capabilities of distribution
4
a greater degree of safety is for branch devices Magnum DS circuit breakers,
required. A wide variety of glass polyester for circuit
breakers and steel for
FDPW fusible switches or
and control assemblies
can be expanded by tying 4
configurations is possible, bolted pressure switches.
together multiple devices
including utility metering,
customer metering, main
fusible switches. These
compartments help
Main buses are rated up
to 6000A.
in electrical distribution 4
eliminate possible contact systems. From a central
devices, branch devices,
accessories and enclosures. with the main bus and Branch circuit breakers range location (on-site or off-site), 4
reduce fault propagation from 151200A frames. an operator uses a personal
Application Description
Three-section construction When circuit breakers are
used, higher ratings and
computer (master control
unit) to monitor, control
4
with each section barriered
Refer to Eatons Consulting
Application Guide.
from the other increased series ratings will
be achieved. Branch fusible
and communicate with
compatible devices on a 4
Device sectioneach
switches are available from distribution system. These
device is mounted in its
own compartment 1001200A. microprocessor-based 4
devices, designed and
Bus bar section
contains both horizontal
Interrupting ratings up to
200,000A are UL listed and
built by Eaton, perform 4
monitoring, protection
4
and vertical buses the bus bar system may be and control functions.
Rear cable braced from a standard
compartment 65,000A up to a maximum
completely isolated 200,000A. 4
from the bus bars
Insulated copper runback.
4
Power is taken from the
protective device by the 4
insulated copper runback
through a standard full 4
height glass polyester
barrier to the rear cable 4
compartment. This design
virtually eliminates the
possibility of accidental
4
contact with the main
buses during installation 4
or maintenance
4
4
Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com V2-T4-15
4.4 Switchboards
Compartmentalized Switchboards
4
4
4
4
4
4
4
4
4
4
4
4
4
V2-T4-16 Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com
Switchboards
Instant Service Switchboards
4.5
Contents
Instant Service Switchboards
Description Page
4
Instant Service Switchboards 4
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V2-T4-18
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V2-T4-20 4
Technical Data and Specifications . . . . . . . . . . V2-T4-21
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V2-T4-21 4
4
4
4
4
Type 1 Indoor Type 3R Outdoor
4
4
Product Description Features, Benefits Standards and 4
and Functions Certifications
Eatons Instant Service
Switchboards are designed These switchboards are two #4600 kcmil lugs per Eatons Instant Service
4
as stocked units to provide
fast delivery to match the
available in either indoor
or outdoor enclosures
phase for cable connection
to the service section.
Switchboards are listed by
Underwriters Laboratories 4
needs of the construction manufactured of code-gauge and comply with all applicable
market. steel with a durable light Distribution panels can
be included for 240 Vac
industry standards. 4
gray finish. All units are
Suitable for use as service
entrance equipment, they
completely enclosed with maximum (single-phase
three-wire or three-phase
These switchboards meet
EUSERC standards as well 4
front, rear and side covers.
combine utility metering four-wire), 480Y/277 Vac as other local utility codes.
provisions with a fused main
Outdoor units include a front
hinged door. (three-phase four-wire) or 4
switch in a single compact 480 Vac (three-phase three- Seismic Qualified
section that can also include a
distribution panel for feeder
The service section includes: wire). The 240V panels have Eatons Instant Service 4
provisions for four Type ED Switchboards are seismically
Main lugs mounted at the
4
and branch circuit breakers. 225A frame circuit breakers tested, seismically qualified and
top (two #4600 kcmil and 24 poles of Type BAB meet or exceed requirements
per phase) for overhead
Application Description feed or for use with an
100A frame circuit breakers.
The 480Y/277V panel has
of the Uniform Building Code
(UBC), the California Building 4
Typical applications for underground pull section provisions for four Type FD Code (CBC) and the
these versatile switchboards A sealable metering and 225A frame circuit breakers International Building Code 4
include small office buildings CT compartment with and 24 poles of Type GHB (IBC) for all seismic zones.
and factories, stores,
supermarkets and
bussing for utility bar
type CTs and two 15-inch
100A frame circuit breakers. 4
The bolt-on type circuit
shopping centers. (381.0 mm) high meter
compartment doorsone
breakers are ordered
separately.
4
with provisions for meter
socket and test block, one For applications that require 4
blank (meter socket is the load circuit conductors to
ordered separately) exit at the top, a loadside
wireway compartment is
4
A 400 or 600A T-Type fused
main switch or 400, 600 or available that bolts to the
service section. 4
800A main circuit breaker
with either load lugs (same
as main lugs)
Standard switchboards
include two 15.00-inch
4
or with connections
to a factory installed
(381.0 mm) high meter
compartment doors, one 4
distribution panel with meter socket provisions
Underground pull sections and one blank. For other 4
arrangements, accessory
are available with lug landing
kits providing studs for units are available. Check 4
incoming cables per utility requirements.
EUSERC standards and 4
Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com V2-T4-17
4.5 Switchboards
Instant Service Switchboard
Product Selection
4
4 Main Fused Switch Only
Main Type 1Indoor Type 3ROutdoor
4
Service Ampere Rating Catalog Number Catalog Number
240 Vac Maximum
4 Single-phase
three-wire
400 MSB423 RMSB423
600 MSB623 RMSB623
4 Three-phase 400 MSB424 RMSB424
four-wire
600 MSB624 RMSB624
4 480Y/277 Vac
4 Three-phase
four-wire
400
600
MSB444
MSB644
RMSB444
RMSB644
4
4 Main Fused Switch with Distribution Panel
Main Type 1Indoor Type 3ROutdoor
4 Service Ampere Rating Catalog Number Catalog Number
240 Vac Maximum 1
4 Single-phase 400 MSBP423 RMSBP423
three-wire
600 MSBP623 RMSBP623
4 Three-phase 400 MSBP424 RMSBP424
four-wire
4 480Y/277 Vac 2
600 MSBP624 RMSBP624
4 Three-phase
four-wire
400 MSBP444 RMSBP444
600 MSBP644 RMSBP644
4
4 Main Breaker Switch Only
Main Type 1Indoor Type 3ROutdoor
4 Service Ampere Rating Catalog Number Catalog Number
240 Vac Maximum 1
4 Single-phase 400 MBB423 RMBB423
three-wire
4 600
800
MBB623
MBB823
RMBB623
RMBB823
4 Three-phase
four-wire
400 MBB424 RMBB424
600 MBB624 RMBB624
4 800 MBB824 RMBB824
480Y/277 Vac 2
4 Three-phase 400 MBB444 RMBB444
four-wire
4 600
800
MBB644
MBB844
RMBB644
RMBB844
4 Notes
1 240V distribution panels have double branch provisions for four Type ED 225A frame circuit breakers and 24 poles of Type BAB 100A frame
4 circuit breakers.
2 480Y/277V distribution panels have double branch provisions for four Type FD 225A frame circuit breakers and 24 poles of Type GHB 100A frame
4
circuit breakers.
Circuit breakers for distribution panels are ordered separately.
4
4
4
4
V2-T4-18 Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com
Switchboards
Instant Service Switchboard
4.5
Main Breaker Only with Distribution Panel
Main Type 1Indoor Type 3ROutdoor
4
Service Ampere Rating Catalog Number Catalog Number
240 Vac Maximum
4
Single-phase
three-wire
400 MBBP423 1 RMBBP423 1
4
600 MBBP623 1 RMBBP623 1
800 MBBP823 2 RMBBP823 2 4
800 MBBP823-P 3 RMBBP823-P 3
800 MBBP823-K 4 RMBBP823-K 4 4
4
Three-phase 400 MBBP424 1 RMBBP424 1
four-wire
600 MBBP624 1 RMBBP624 1
800 MBBP824 2
3
RMBBP824 2
4
800 MBBP824-P RMBBP824-P 3
800 MBBP824-K 4 RMBBP824-K 4 4
480Y/277 Vac
Three-phase 400 MBBP444 5 RMBBP444 5 4
four-wire
600
800
MBBP644 5
MBBP844 2
RMBBP644 5
RMBBP844 2
4
800 MBBP844-K 4 RMBBP844-K 4 4
4
Underground Pull SectionsSame Depth as Switchboard with Provisions for
Lug Landing Kit
4
Section Width Type 1Indoor Type 3ROutdoor
Inches (mm) Catalog Number Catalog Number
4
24.00 (609.6) 6 UG24W RUG24W
30.00 (762.0) UG30W RUG30W 4
NEMA Type 1 pull section can be installed separate from service section. Add side closer plate, catalog number UGCP.
4
Lug Landing Kits for Underground Pull Sections 4
Maximum Catalog
Ampere Rating Service Number 4
400 Single-phase three-wire LL4003
Three-phase four-wire LL4004
4
800 Single-phase three-wire LL8003 7
4
Three-phase four-wire LL8004 7
4
Load Side Wireway12 Inches (304.8 mm) Wide Same Depth as Switchboard 4
Type Catalog Number
Type 1Indoor LSS12W 4
4
Type 3ROutdoor RLSS12W
Notes
1 240V distribution panels have double branch provisions for four Type ED 225A frame circuit breakers and 24 poles of Type BAB 100A frame
circuit breakers.
4
2 800A distribution panels have double branch provision for six Type FD 225A frame circuit breakers only.
3 Suffix-P: four Type FD 225A frame circuit breakers and 24 poles of Type GHB 100A frame circuit breakers. 4
4 Suffix-K: one Type KD OR HKD 400A frame circuit breakers and four Type FD 225A frame circuit breakers.
5 480Y/277V distribution panels have double branch provisions for four Type FD 225A frame circuit breakers and 24 poles of Type GHB 100A frame
circuit breakers.
4
6 Check utility requirementsmost EUSERC utilities require 30-inch (762.0 mm) width.
7 Mounts in 30-inch (762.0 mm) wide section only. 4
Circuit breakers for distribution panels are ordered separately.
4
4
Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com V2-T4-19
4.5 Switchboards
Instant Service Switchboards
Accessories
4
Meter Compartment Doors(Meter Sockets Not Included) Circuit Breakers for Distribution Panels 480Y/277 Vac
4 Height Width Drilling Catalog Number
(Three-Phase Four-Wire)
Ampere Single-Pole Two-Pole Three-Pole
4 15.00 (381.0) 32.00 (812.8) Blank MD150 Rating Catalog Number Catalog Number Catalog Number
One socket MD151
15 GHB1015I GHB2015I GHB3015I
4 30.00 (762.0) 32.00 (812.8) Blank MD300
20 GHB1020I GHB2020I GHB3030I
Two sockets MD302
4 30
40
GHB1030I
GHB1040I
GHB2030I
GHB2040I
GHB3030I
GHB3040I
Number of Jaws Catalog Number Number of Jaws Catalog Number 60 GHB1060I GHB2060I GHB3060I
4 4 M4 8 M8
70 GHB2070I GHB3070I
90 GHB2090I GHB3090I
4 5 1
2
M5 13
3
M13
100 GHB2100I GHB3100I
6 M6 15 M15
4 100 FD2100I FD3100I
125 FD2125I FD3135I
4 50 BAB1050I BAB2050I BAB2050HI BAB3050HI Special Utility OptionsSelect for the Following Utilities
60 BAB1060I BAB2060I BAB2060HI BAB3060HI Utility Company Catalog Number
4 70 BAB2070I BAB2070HI BAB3070HI City of Anaheim ISTAHEIM
4
90 BAB2090I BAB2090HI BAB3090HI City of Burbank ISTBANK
100 BAB2100I BAB2100HI BAB3100HI
4 breakers only.
3 Suffix-P: four Type FD 225A frame circuit breakers and 24 poles of Type GHB 100A frame
circuit breakers.
4
4
4
4
V2-T4-20 Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com
Switchboards
Instant Service Switchboards
4.5
Technical Data and Specifications
120/240 Vac, single-phase three-wire
4
208Y/120V or 240/120 Vac, three-phase four-wire
4
240 Delta/120 Vac, three-phase four-wire
480Y/277 Vac, three-phase four-wire 4
480 Vac, three-phase three-wire
Interrupting Ratings (Series Rating) 4
65,000 rms symmetrical amperes at 240 Vac, using
4
Dimensions 4
Approximate Dimensions in Inches (mm)
4
Instant Service Switchboards
Height Width Depth
4
Indoor 4
90.00 (2286.0) 32.00 (812.8) 14.00 (355.6)
Outdoor 4
90.00 (2286.0) 38.00 (965.2) 26.00 (660.4)
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com V2-T4-21
4.6 Switchboards
Roll-Up Generator Termination Box
Contents
4 Roll-Up Generator Termination Box
Description Page
4 Roll-Up Generator Termination Box
Technical Data and Specifications . . . . . . . . . . . V2-T4-23
4 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V2-T4-36
4
4
4
4
4
4
4
4 Product Description Features
4 Eatons roll-up generator
termination boxes (RUGTB)
Enclosure Terminations
are designed as an The enclosure is free- The enclosure uses feet All roll-up generator
4 intermediate termination standing with feet on the that raise the termination termination boxes contain
cabinet between temporary, bottom, providing access to compartment off finished a termination/lug landing
4 portable roll-up generator the cable connections for
temporary roll-up generator
grade by 18 inches
(457.2 mm). Enclosure feet
for three phases and neutral
plus ground. Line termination
and the facility being served.
4 The RUGTB is designed for
permanent installation and
terminations. The enclosure
is made from code gauge
have provisions for anchoring
the RUGTB. Anchor bolts
options include mechanical
lugs, one-hole and two-hole
steel and is suitable for either secure the RUGTB and shall compression lugs, one-hole
4 is secured to a concrete pad
with bolts. outdoor or indoor installation be encased in a concrete and two-hole compression
(Type 3R construction). The pad by the installer in a lug provisions, and quick
4 The RUGTB includes
line terminations for the
enclosure is powder coat
painted ANSI 61 gray. Each
manner that is suitable as a
permanent base for the unit.
disconnect.
Lug provisions are provided
4 temporary connection of
the portable generator and
enclosure houses line and
load phase, neutral and
A template for anchor bolt
installation is available from with bolt configurations as
permanent connections ground connections. Access the manufacturer. described in the catalog
4 on the load side to the is provided at the bottom of data on the following pages.
secondary disconnect in the the enclosure for both the The enclosure contains a Where lug provisions are
4 facility, which is interlocked temporary connections to the sturdy, lockable, hinged door
for access to the termination
ordered, lugs are supplied
by others.
with the main overcurrent roll-up generator and
4 device in a manner that permanent connections to compartment by qualified
personnel as described in
ensures that only one the facilitys generator
NFPA 70E and the National
Standards and
4 (either the service main or
the generator main) can be
overcurrent disconnecting
means. The permanent Electrical Code. Feeder Certifications
energized at any one time. connection section at the conductor entry is provided in UL 1773 listed
4 The conductors and conduits bottom of the enclosure the bottom of the enclosure
for the line side (generator).
termination boxes
must be sized and suitable contains a fixed mounting 600 Vac maximum
4 for carrying the load ratings plate. The temporary A hinged bottom plate is
provided on the line side for
Amperage ratings: 800,
marked on the equipment per generator connection to the 1200, 1600, 2000 and 2500
access to line terminations.
4 the National Electrical Code. RUGTB contains a hinged
cover that allows access to The permanent load
Assembly short-circuit
connections (feeding to rating: 25,000A rms
4
the enclosure for generator symmetrical
conductors. the facility overcurrent
device) exit the enclosure Marked Suitable for use
4 from the bottom. on the line side of service
equipment per UL 1773
4
4
4
V2-T4-22 Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com
Switchboards
Roll-Up Generator Termination Box
4.6
Technical Data and Specifications
Approximate Dimensions in Inches (mm)
4
Roll-Up Generator Termination Box with Line and Load Mechanical Box Lugs 1 4
Ampere
Rating
Dimensions
Height Width Depth
Mechanical Box Lugs Line
Termination Number, Range and Type
Mechanical Box Lugs Load
Termination Number, Range and Type Catalog Number
4
800 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (3) 4/0500 kcmil Al/Cu (3) 4/0500 kcmil Al/Cu GTB08MAMA
4
(3) 4/0500 kcmil Al/Cu (2) 3/0750 kcmil Al/Cu GTB08MAMB
(2) 3/0750 kcmil Al/Cu (3) 4/0500 kcmil Al/Cu GTB08MBMA 4
(2) 3/0750 kcmil Al/Cu (2) 3/0750 kcmil Al/Cu GTB08MBMB
1200 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (4) 4/0500 kcmil Al/Cu (4) 4/0500 kcmil Al/Cu GTB12MCMC 4
4
(4) 4/0500 kcmil Al/Cu (3) 3/0750 kcmil Al/Cu GTB12MCMD
(3) 3/0750 kcmil Al/Cu (4) 4/0500 kcmil Al/Cu GTB12MDMC
(3) 3/0750 kcmil Al/Cu (3) 3/0750 kcmil Al/Cu GTB12MDMD
4
1600 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (5) 4/0500 kcmil Al/Cu (5) 4/0500 kcmil Al/Cu GTB16MEME
(5) 4/0500 kcmil Al/Cu (4) 3/0750 kcmil Al/Cu GTB16MEMF 4
(4) 3/0750 kcmil Al/Cu (5) 4/0500 kcmil Al/Cu GTB16MFME
(4) 3/0750 kcmil Al/Cu (4) 3/0750 kcmil Al/Cu GTB16MFMF 4
4
2000 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (6) 4/0500 kcmil Al/Cu (6) 4/0500 kcmil Al/Cu GTB20MGMG
(6) 4/0500 kcmil Al/Cu (5) 3/0750 kcmil Al/Cu GTB20MGMH
(5) 3/0750 kcmil Al/Cu (6) 4/0500 kcmil Al/Cu GTB20MHMG
4
(5) 3/0750 kcmil Al/Cu (5) 3/0750 kcmil Al/Cu GTB20MHMH
2500 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (8) 4/0500 kcmil Al/Cu (8) 4/0500 kcmil Al/Cu GTB25MJMJ 4
(8) 4/0500 kcmil Al/Cu (7) 3/0750 kcmil Al/Cu GTB25MJMK
(7) 3/0750 kcmil Al/Cu (8) 4/0500 kcmil Al/Cu GTB25MKMJ 4
4
(7) 3/0750 kcmil Al/Cu (7) 3/0750 kcmil Al/Cu GTB25MJMJ
Roll-Up Generator Termination Box with Line Mechanical Box Lugs; Load Single-Hole Compression Lugs 12 4
Ampere
Rating
Dimensions
Height Width Depth
Mechanical Box Lugs Line
Termination Number, Range and Type
Single-Hole Compression Load
Termination Number, Range and Type Catalog Number
4
800 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (3) 4/0500 kcmil Al/Cu (3) 4/0500 kcmil Al/Cu GTB08MACA
4
(3) 4/0500 kcmil Al/Cu (2) 3/0750 kcmil Al/Cu GTB08MACB
(2) 3/0750 kcmil Al/Cu (3) 4/0500 kcmil Al/Cu GTB08MBCA 4
(2) 3/0750 kcmil Al/Cu (2) 3/0750 kcmil Al/Cu GTB08MBCB
1200 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (4) 4/0500 kcmil Al/Cu (4) 4/0500 kcmil Al/Cu GTB12MCCC 4
4
(4) 4/0500 kcmil Al/Cu (3) 3/0750 kcmil Al/Cu GTB12MCCD
(3) 3/0750 kcmil Al/Cu (4) 4/0500 kcmil Al/Cu GTB12MDCC
(3) 3/0750 kcmil Al/Cu (3) 3/0750 kcmil Al/Cu GTB12MDCD
4
1600 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (5) 4/0500 kcmil Al/Cu (5) 4/0500 kcmil Al/Cu GTB16MECE
(5) 4/0500 kcmil Al/Cu (4) 3/0750 kcmil Al/Cu GTB16MECF 4
(4) 3/0750 kcmil Al/Cu (5) 4/0500 kcmil Al/Cu GTB16MFCE
(4) 3/0750 kcmil Al/Cu (4) 3/0750 kcmil Al/Cu GTB16MFCF 4
4
2000 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (6) 4/0500 kcmil Al/Cu (6) 4/0500 kcmil Al/Cu GTB20MGCG
(6) 4/0500 kcmil Al/Cu (5) 3/0750 kcmil Al/Cu GTB20MGCH
(5) 3/0750 kcmil Al/Cu (6) 4/0500 kcmil Al/Cu GTB20MHCG
4
(5) 3/0750 kcmil Al/Cu (5) 3/0750 kcmil Al/Cu GTB20MHCH
2500 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (8) 4/0500 kcmil Al/Cu (8) 4/0500 kcmil Al/Cu GTB25MJCJ 4
(8) 4/0500 kcmil Al/Cu (7) 3/0750 kcmil Al/Cu GTB25MJCK
(7) 3/0750 kcmil Al/Cu (8) 4/0500 kcmil Al/Cu GTB25MKCJ 4
4
(7) 3/0750 kcmil Al/Cu (7) 3/0750 kcmil Al/Cu GTB25MJCJ
Notes
1 Line side mechanical lugs are factory selected and installed.
2 Load side Anderson, single-hole compression lugs are factory selected and installed.
4
Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com V2-T4-23
4.6 Switchboards
Roll-Up Generator Termination Box
4 Rating
800
Height
78.00 (1981.2)
Width
45.00 (1143.0)
Depth
24.00 (609.6)
Termination Number, Range and Type
(3) 4/0500 kcmil Al/Cu
Termination Cu Only Wire Size
(3) 350 kcmil Cu only
Catalog Number
GTB08MACL
4
1200 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (4) 4/0500 kcmil Al/Cu (4) 500 kcmil Cu only GTB12MCCN
(4) 4/0500 kcmil Al/Cu (3) 600 kcmil Cu only GTB12MCCP
4
(8) 4/0500 kcmil Al/Cu (6) 600 kcmil Cu only GTB25MJCY
(8) 4/0500 kcmil Al/Cu (6) 750 kcmil Cu only GTB25MJCZ
4
Notes
1 Line side mechanical lugs are factory selected and installed.
2 Load side factory installed Burndy, two-hole, short barrel compression lugs suitable for copper wire only requires a 45-inch (1143.0 mm) wide enclosure.
4
4
4
4
4
4
4
4
4
4
V2-T4-24 Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com
Switchboards
Roll-Up Generator Termination Box
4.6
Approximate Dimensions in Inches (mm)
4
Roll-Up Generator Termination Box with Line Mechanical Box Lugs; Load Provisions Only, Single-Hole Compression Lugs 12
Ampere Dimensions Mechanical Box Lugs Line Single-Hole Compression Load
4
4
Rating Height Width Depth Termination Number, Range and Type Provisions Only Number and Range Catalog Number
800 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (3) 4/0500 kcmil Al/Cu (3) Provisions per phase GTB08MAP1
(2) 3/0750 kcmil Al/Cu (3) Provisions per phase GTB08MBP1 4
1200 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (4) 4/0500 kcmil Al/Cu (4) Provisions per phase GTB12MCP2
(3) 3/0750 kcmil Al/Cu (4) Provisions per phase GTB12MDP2 4
1600 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (5) 4/0500 kcmil Al/Cu (5) Provisions per phase GTB16MEP3
(4) 3/0750 kcmil Al/Cu (5) Provisions per phase GTB16MFP3
4
2000 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (6) 4/0500 kcmil Al/Cu (6) Provisions per phase GTB20MGP4
4
(5) 3/0750 kcmil Al/Cu (6) Provisions per phase GTB20MHP4
2500 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (8) 4/0500 kcmil Al/Cu (8) Provisions per phase GTB25MJP5 4
(7) 3/0750 kcmil Al/Cu (8) Provisions per phase GTB25MKP5
4
Roll-Up Generator Termination Box with Line Mechanical Box Lugs; Load Provisions Only, Two-Hole Compression Lugs 134 4
Dimensions
Ampere
Rating Height Width Depth
Mechanical Box Lugs Line
Termination Number, Range and Type
Two-Hole Compression Load
Provisions Only Number and Range Catalog Number 4
800 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (3) 4/0500 kcmil Al/Cu
(2) 3/0750 kcmil Al/Cu
(3) Provisions per phase
(3) Provisions per phase
GTB08MAPA
GTB08MBPA
4
1200 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (4) 4/0500 kcmil Al/Cu (4) Provisions per phase GTB12MCPB 4
(3) 3/0750 kcmil Al/Cu (4) Provisions per phase GTB12MDPB
1600 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (5) 4/0500 kcmil Al/Cu (5) Provisions per phase GTB16MEPC 4
(4) 3/0750 kcmil Al/Cu (5) Provisions per phase GTB16MFPC
2000 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (6) 4/0500 kcmil Al/Cu (6) Provisions per phase GTB20MGPD
4
(5) 3/0750 kcmil Al/Cu (6) Provisions per phase GTB20MHPD
4
2500 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (8) 4/0500 kcmil Al/Cu (8) Provisions per phase GTB25MJPE
(7) 3/0750 kcmil Al/Cu (8) Provisions per phase GTB25MKPE 4
4
Notes
1 Line side mechanical lugs are factory selected and installed.
2 Load side factory installed 3/8-inch bolt provisions for single-hole compression lugs (lugs furnished by others).
3 Load side factory installed 1/2-inch bolt provisions on 1-3/4-inch hole centers for two-hole compression lugs (lugs furnished by others).
4 Requires 45-inch (1143.0 mm) wide enclosure.
4
4
4
4
4
4
4
4
4
4
4
4
Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com V2-T4-25
4.6 Switchboards
Roll-Up Generator Termination Box
4 1600 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (5) 4/0500 kcmil Al/Cu
(5) 4/0500 kcmil Al/Cu
(5) 4/0500 kcmil Al/Cu
(4) 3/0750 kcmil Al/Cu
GTB16CEME
GTB16CEMF
4
Roll-Up Generator Termination Box with Line and Load Single-Hole Compression Lugs 3
4 Ampere Dimensions Single-Hole Compression Line Single-Hole Compression Load
Rating Height Width Depth Termination Number, Range and Type Termination Number, Range and Type Catalog Number
4 800 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (3) 4/0500 kcmil Al/Cu (3) 4/0500 kcmil Al/Cu GTB08CACA
4 1600 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (5) 4/0500 kcmil Al/Cu
(5) 4/0500 kcmil Al/Cu
(5) 4/0500 kcmil Al/Cu
(4) 3/0750 kcmil Al/Cu
GTB16CECE
GTB16CECF
4 Notes
1 Line side Anderson, single-hole compression lugs are factory selected and installed.
2 Load side mechanical lugs are factory selected and installed.
4 3 Line side and load Anderson, single-hole compression lugs are factory selected and installed.
Notes
4
4
1 Line side Anderson, single-hole compression lugs are factory selected and installed.
2 Load side factory installed Burndy, two-hole, short barrel compression lugs suitable for copper wire only.
3 Requires 45-inch (1143.0 mm) wide enclosure.
4 Load side factory installed 3/8-inch bolt provisions for single-hole compression lugs (lugs furnished by others). 4
Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com V2-T4-27
4.6 Switchboards
Roll-Up Generator Termination Box
4 Rating
800
Height
78.00 (1981.2)
Width
45.00 (1143.0)
Depth
24.00 (609.6)
Termination Number, Range and Type
(3) 4/0500 kcmil Al/Cu
Provisions Only Number and Range
(3) Provisions per phase
Catalog Number
GTB08CAPA
4
1600 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (5) 4/0500 kcmil Al/Cu (5) Provisions per phase GTB16CEPC
(4) 3/0750 kcmil Al/Cu (5) Provisions per phase GTB16CGPC
4 2000 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (6) 4/0500 kcmil Al/Cu (6) Provisions per phase GTB20CGPD
(5) 3/0750 kcmil Al/Cu (6) Provisions per phase GTB20CHPD
4 2500 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (8) 4/0500 kcmil Al/Cu (8) Provisions per phase GTB25CJPE
(7) 3/0750 kcmil Al/Cu (8) Provisions per phase GTB25CKPE
4
4 Roll-Up Generator Termination Box with Line Two-Hole Compression Lugs and Load Mechanical Box Lugs 345
Ampere Dimensions Two-Hole Compression Line Mechanical Box Lugs Load
4 Rating Height Width Depth Termination Cu Only Wire Size Termination Number, Range and Type Catalog Number
800 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (3) 350 kcmil Cu only (3) 4/0500 kcmil Al/Cu GTB08CLMA
4 (3) 350 kcmil Cu only (2) 3/0750 kcmil Al/Cu GTB08CLMB
4 1200 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (4) 500 kcmil Cu only (4) 4/0500 kcmil Al/Cu GTB12CNMC
(4) 500 kcmil Cu only (3) 3/0750 kcmil Al/Cu GTB12CNMD
4 (3) 600 kcmil Cu only (4) 4/0500 kcmil Al/Cu GTB12CPMC
(3) 600 kcmil Cu only (3) 3/0750 kcmil Al/Cu GTB12CPMD
4 (3) 750 kcmil Cu only (4) 4/0500 kcmil Al/Cu GTB12CQMC
4
(4) 750 kcmil Cu only (5) 4/0500 kcmil Al/Cu GTB16CTME
(4) 750 kcmil Cu only (4) 3/0750 kcmil Al/Cu GTB16CTMF
4 2000 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (6) 500 kcmil Cu only (6) 4/0500 kcmil Al/Cu GTB20CUMG
(6) 500 kcmil Cu only (5) 3/0750 kcmil Al/Cu GTB20CUMH
4 (5) 600 kcmil Cu only (6) 4/0500 kcmil Al/Cu GTB20CVMG
(5) 600 kcmil Cu only (5) 3/0750 kcmil Al/Cu GTB20CVMH
4 (5) 750 kcmil Cu only (6) 4/0500 kcmil Al/Cu GTB20CWMG
4 Notes
1 Line side Anderson, single-hole compression lugs are factory selected and installed.
4
2 Load side factory installed 1/2-inch bolt provisions on 1-3/4-inch hole centers for two-hole compression lugs (lugs furnished by others).
3 Requires 45-inch (1143.0 mm) wide enclosure.
4 Line side factory installed Burndy, two-hole, short barrel compression lugs suitable for copper wire only.
4 Rating
800
Height
78.00 (1981.2)
Width
45.00 (1143.0)
Depth
24.00 (609.6)
Termination Cu Only Wire Size
(3) 350 kcmil Cu only
Termination Cu Only Wire Size
(3) 350 kcmil Cu only
Catalog Number
GTB08CLCL
4
1200 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (4) 500 kcmil Cu only (4) 500 kcmil Cu only GTB12CNCN
(4) 500 kcmil Cu only (3) 600 kcmil Cu only GTB12CNCP
4 1600 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (5) 500 kcmil Cu only (5) 500 kcmil Cu only GTB16CRCR
(5) 500 kcmil Cu only (4) 600 kcmil Cu only GTB16CRCS
4 (5) 500 kcmil Cu only (4) 750 kcmil Cu only GTB16CRCT
(4) 600 kcmil Cu only (5) 500 kcmil Cu only GTB16CSCR
4 (4) 600 kcmil Cu only (4) 600 kcmil Cu only GTB16CSCS
4
(6) 500 kcmil Cu only (5) 600 kcmil Cu only GTB20CUCV
(6) 500 kcmil Cu only (5) 750 kcmil Cu only GTB20CUCW
4
(5) 750 kcmil Cu only (5) 750 kcmil Cu only GTB20CWCW
2500 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (7) 500 kcmil Cu only (7) 500 kcmil Cu only GTB25CXCX
Notes
4 Line and load side factory installed Burndy, two-hole, short barrel compression lugs suitable for copper wire only.
Requires 45-inch (1143.0 mm) wide enclosure.
4
4
4
V2-T4-30 Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com
Switchboards
Roll-Up Generator Termination Box
4.6
Approximate Dimensions in Inches (mm)
4
Roll-Up Generator Termination Box with Line Two-Hole Compression Lugs; Load Provisions Only, Single-Hole
Compression Lugs 123 4
Dimensions
Ampere
Rating Height Width Depth
Two-Hole Compression Line
Termination Cu Only Wire Size
Single-Hole Compression Load Provisions
Only Number and Range Catalog Number 4
800 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (3) 350 kcmil Cu only
(3) 400 kcmil Cu only
(3) Provisions per phase
(3) Provisions per phase
GTB08CLP1
GTB08CMP1
4
1200 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (4) 500 kcmil Cu only (4) Provisions per phase GTB12CNP2 4
(3) 600 kcmil Cu only (4) Provisions per phase GTB12CPP2
(3) 750 kcmil Cu only (4) Provisions per phase GTB12CQP2 4
2000 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (6) 500 kcmil Cu only (6) Provisions per phase GTB20CUP4
(5) 600 kcmil Cu only (6) Provisions per phase GTB20CVP4
4
(5) 750 kcmil Cu only (6) Provisions per phase GTB20CWP4
4
2500 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (7) 500 kcmil Cu only (8) Provisions per phase GTB25CXP5
(6) 600 kcmil Cu only (8) Provisions per phase GTB25CYP6 4
(6) 750 kcmil Cu only (8) Provisions per phase GTB25CZP6
4
Roll-Up Generator Termination Box with Two-Hole Compression Lugs; Load Provisions Only, Two-Hole Compression Lugs 4 4
Dimensions
Ampere
Rating Height Width Depth
Two-Hole Compression Line
Termination Cu Only Wire Size
Two-Hole Compression Load Provisions
Only Number and Range Catalog Number 4
800 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (3) 350 kcmil Cu only
(3) 400 kcmil Cu only
(3) Provisions per phase
(3) Provisions per phase
GTB08CLPA
GTB08CMPA
4
1200 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (4) 500 kcmil Cu only (4) Provisions per phase GTB12CNPB 4
(3) 600 kcmil Cu only (4) Provisions per phase GTB12CPPB
(3) 750 kcmil Cu only (4) Provisions per phase GTB12CQPB 4
1600 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (5) 500 kcmil Cu only (5) Provisions per phase GTB16CRPC
(4) 600 kcmil Cu only (5) Provisions per phase GTB16CSPC
4
(4) 750 kcmil Cu only (5) Provisions per phase GTB16CTPC
4
2000 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (6) 500 kcmil Cu only (6) Provisions per phase GTB20CUPD
(5) 600 kcmil Cu only (6) Provisions per phase GTB20CVPD 4
(5) 750 kcmil Cu only (6) Provisions per phase GTB20CWPD
2500 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (7) 500 kcmil Cu only (8) Provisions per phase GTB25CXPE 4
4
(6) 600 kcmil Cu only (8) Provisions per phase GTB25CYPE
(6) 750 kcmil Cu only (8) Provisions per phase GTB25CZPE
Notes
1 Line side factory installed Burndy, two-hole, short barrel compression lugs suitable for copper wire only.
4
2 Load side factory installed 3/8-inch bolt provisions for single-hole compression lugs (lugs furnished by others).
3 Requires 45-inch (1143.0 mm) wide enclosure.
4
4
4 Load side factory installed 1/2-inch bolt provisions on 1-3/4-inch hole centers for two-hole compression lugs (lugs furnished by others).
4
4
4
4
4
4
4
Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com V2-T4-31
4.6 Switchboards
Roll-Up Generator Termination Box
4 Ampere Dimensions Single-Hole Compression Line Provisions Mechanical Box Lugs Load
4 Rating
800
Height
78.00 (1981.2)
Width
36.00 (914.4)
Depth
24.00 (609.6)
Only Number and Range
(3) Provisions per phase
Termination Number, Range and Type
(3) 4/0500 kcmil Al/Cu
Catalog Number
GTB08P1MA
4
1600 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (5) Provisions per phase (5) 4/0500 kcmil Al/Cu GTB16P3ME
(5) Provisions per phase (4) 3/0750 kcmil Al/Cu GTB16P3MF
4 2000 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (6) Provisions per phase (6) 4/0500 kcmil Al/Cu GTB20P4MG
(6) Provisions per phase (5) 3/0750 kcmil Al/Cu GTB20P4MH
4 2500 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (8) Provisions per phase (8) 4/0500 kcmil Al/Cu GTB25P5MJ
(8) Provisions per phase (7) 3/0750 kcmil Al/Cu GTB25P5MK
4
4 Roll-Up Generator Termination Box with Line Single-Hole Compression Lug Provisions; Load Single-Hole
Compression Lugs 13
4 Ampere Dimensions Single-Hole Compression Line Provisions Single-Hole Compression Load Termination
Rating Height Width Depth Only Number and Range Number, Range and Type Catalog Number
4 800 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (3) Provisions per phase (3) 4/0500 kcmil Al/Cu GTB08P1CA
4 2500 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (8) Provisions per phase (8) 4/0500 kcmil Al/Cu GTB25P5CJ
(8) Provisions per phase (7) 3/0750 kcmil Al/Cu GTB25P5CK
4 Notes
1 Line side factory installed 3/8-inch bolt provisions for single-hole compression lugs (lugs furnished by others).
4
4
4
4
4
4
4
4
4
4
4
V2-T4-32 Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com
Switchboards
Roll-Up Generator Termination Box
4.6
Approximate Dimensions in Inches (mm)
4
Roll-Up Generator Termination Box with Line Single-Hole Compression Lug Provisions; Load Two-Hole
Compression Lugs 123 4
Dimensions
Ampere
Rating Height Width Depth
Single-Hole Compression Line Provisions
Only Number and Range
Two-Hole Compression Load Termination
Cu Only Wire Size Catalog Number 4
800 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (3) 4/0500 kcmil
(3) 4/0500 kcmil
(3) 350 kcmil Cu only
(3) 400 kcmil Cu only
GTB08P1CL
GTB08P1CM
4
1200 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (4) 4/0500 kcmil (4) 500 kcmil Cu only GTB12P2CN 4
(4) 4/0500 kcmil (3) 600 kcmil Cu only GTB12P2CP
(4) 4/0500 kcmil (3) 750 kcmil Cu only GTB12P2CQ 4
1600 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (5) 4/0500 kcmil (5) 500 kcmil Cu only GTB16P3CR
(5) 4/0500 kcmil (4) 600 kcmil Cu only GTB16P3CS
4
(5) 4/0500 kcmil (4) 750 kcmil Cu only GTB16P3CT
4
2000 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (6) 4/0500 kcmil (6) 500 kcmil Cu only GTB20P4CU
(6) 4/0500 kcmil (5) 600 kcmil Cu only GTB20P4CU 4
(6) 4/0500 kcmil (5) 750 kcmil Cu only GTB20P4CW
2500 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (8) 4/0500 kcmil (7) 500 kcmil Cu only GTB25P5CX 4
4
(8) 4/0500 kcmil (6) 600 kcmil Cu only GTB25P5CY
(8) 4/0500 kcmil (6) 750 kcmil Cu only GTB25P5CZ
4
Roll-Up Generator Termination Box with Line Single-Hole Compression Lug Provisions; Load Single-Hole Compression Lugs
4
4
Ampere Dimensions Single-Hole Compression Line Provisions Single-Hole Compression Load Provisions
Rating Height Width Depth Only Number and Range Only Number and Range Catalog Number
4
800 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (3) Provisions per phase (3) Provisions per phase GTB08P1P1
1200 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (4) Provisions per phase (4) Provisions per phase GTB12P2P2 4
1600 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (5) Provisions per phase (5) Provisions per phase GTB16P3P3
2000 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (6) Provisions per phase (6) Provisions per phase GTB20P4P4
4
2500 78.00 (1981.2) 36.00 (914.4) 24.00 (609.6) (8) Provisions per phase (8) Provisions per phase GTB25P5P5
4
Notes
1 Line side factory installed 3/8-inch bolt provisions for single-hole compression lugs (lugs furnished by others).
2 Load side factory installed Burndy, two-hole, short barrel compression lugs suitable for copper wire only.
4
4
3 Requires 45-inch (1143.0 mm) wide enclosure.
4 Line and load side factory installed 3/8-inch bolt provisions for single-hole compression lugs (lugs furnished by others).
4
4
4
4
4
4
4
4
4
4
4
Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com V2-T4-33
4.6 Switchboards
Roll-Up Generator Termination Box
4 Ampere Dimensions Single-Hole Compression Line Provisions Two-Hole Compression Load Provisions
Rating Height Width Depth Only Number and Range Only Number and Range Catalog Number
4 800
1200
78.00 (1981.2)
78.00 (1981.2)
45.00 (1143.0)
45.00 (1143.0)
24.00 (609.6)
24.00 (609.6)
(3) Provisions per phase
(4) Provisions per phase
(3) Provisions per phase
(4) Provisions per phase
GTB08P1PA
GTB12P2PB
4 1600 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (5) Provisions per phase (5) Provisions per phase GTB16P3PC
2000 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (6) Provisions per phase (6) Provisions per phase GTB20P4PD
4 2500 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (8) Provisions per phase (8) Provisions per phase GTB25P5PE
4
Roll-Up Generator Termination Box with Line Single-Hole Compression Lug Provisions; Load Mechanical Box Lugs 234
4 Ampere Dimensions Two-Hole Compression Line Provisions Mechanical Box Lugs Load
Rating Height Width Depth Only Number and Range Termination Number, Range and Type Catalog Number
4 800 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (3) Provisions per phase (3) 4/0500 kcmil GTB08PAMA
4 2000 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (6) Provisions per phase
(6) Provisions per phase
(6) 4/0500 kcmil
(5) 3/0750 kcmil
GTB20PDMG
GTB20PDMH
4 2500 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (8) Provisions per phase (8) 4/0500 kcmil GTB25PEMJ
(8) Provisions per phase (7) 3/0750 kcmil GTB25PEMK
4
4 Roll-Up Generator Termination Box with Line Two-Hole Compression Lug Provisions; Load Single-Hole
Compression Lugs 235
4 Ampere Dimensions Two-Hole Compression Line Provisions Single-Hole Compression Load
Rating Height Width Depth Only Number and Range Termination Number, Range and Type Catalog Number
4 800 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (3) Provisions per phase (3) 4/0500 kcmil Al/Cu GTB08PACA
4
(3) Provisions per phase (2) 3/0750 kcmil Al/Cu GTB08PACB
1200 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (4) Provisions per phase (4) 4/0500 kcmil Al/Cu GTB12PBCC
4 2500 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (8) Provisions per phase
(8) Provisions per phase
(8) 4/0500 kcmil Al/Cu
(7) 3/0750 kcmil Al/Cu
GTB25PECJ
GTB25PECK
4 Notes
1 Line side factory installed 3/8-inch bolt provisions for single-hole compression lugs (lugs furnished by others).
4 2 Load side factory installed 1/2-inch bolt provisions on 1-3/4-inch hole centers for two-hole compression lugs (lugs furnished by others).
3 Requires 45-inch (1143.0 mm) wide enclosure.
4
4 Load side mechanical lugs are factory selected and installed.
5 Load side Anderson, single-hole compression lugs are factory selected and installed.
4
4
4
4
V2-T4-34 Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com
Switchboards
Roll-Up Generator Termination Box
4.6
Approximate Dimensions in Inches (mm)
4
Roll-Up Generator Termination Box with Line TWo-Hole Compression Lug Provisions; Load Two-Hole Compression Lugs 123
Ampere Dimensions Two-Hole Compression Line Provisions Two-Hole Compression Load
4
4
Rating Height Width Depth Only Number and Range Termination Cu Only Wire Size Catalog Number
800 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (3) Provisions per phase (3) 350 kcmil Cu only GTB08PACL
(3) Provisions per phase (3) 400 kcmil Cu only GTB08PACM 4
1200 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (4) Provisions per phase (4) 500 kcmil Cu only GTB12PBCN
(4) Provisions per phase (3) 600 kcmil Cu only GTB12PBCP 4
(4) Provisions per phase (3) 750 kcmil Cu only GTB12PBCQ
1600 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (5) Provisions per phase (5) 500 kcmil Cu only GTB16PCCR
4
(5) Provisions per phase (4) 600 kcmil Cu only GTB16PCCS
4
(5) Provisions per phase (4) 750 kcmil Cu only GTB16PCCT
2000 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (6) Provisions per phase (6) 500 kcmil Cu only GTB20PDCU 4
(6) Provisions per phase (5) 600 kcmil Cu only GTB20PDCU
(6) Provisions per phase (5) 750 kcmil Cu only GTB20PDCW 4
4
2500 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (8) Provisions per phase (7) 500 kcmil Cu only GTB25PECX
(8) Provisions per phase (6) 600 kcmil Cu only GTB25PECY
(8) Provisions per phase (6) 750 kcmil Cu only GTB25PECZ
4
4
Roll-Up Generator Termination Box with Line Two-Hole Compression Lug Provisions; Load Single-Hole
Compression Lugs 134
Dimensions
4
Ampere Two-Hole Compression Line Provisions Single-Hole Compression Load Provisions
Rating Height Width Depth Only Number and Range Only Number and Range Catalog Number
4
800 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (3) Provisions per phase (3) Provisions per phase GTB08PAP1
1200 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (4) Provisions per phase (4) Provisions per phase GTB12PBP2 4
1600 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (5) Provisions per phase (5) Provisions per phase GTB16PCP3
2000 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (6) Provisions per phase (6) Provisions per phase GTB20PDP4
4
2500 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (8) Provisions per phase (8) Provisions per phase GTB25PEP5
4
Roll-Up Generator Termination Box with Line Two-Hole Compression Lug Provisions; Load Two-Hole Compression
4
4
Lugs Provisions 35
Ampere Dimensions Two-Hole Compression Line Provisions Two-Hole Compression Load Provisions
Rating Height Width Depth Only Number and Range Only Number and Range Catalog Number
4
800 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (3) Provisions per phase (3) Provisions per phase GTB08PAPA
1200 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (4) Provisions per phase (4) Provisions per phase GTB12PBPB 4
1600 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (5) Provisions per phase (5) Provisions per phase GTB16PCPC
2000 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (6) Provisions per phase (6) Provisions per phase GTB20PDPD 4
4
2500 78.00 (1981.2) 45.00 (1143.0) 24.00 (609.6) (8) Provisions per phase (8) Provisions per phase GTB25PEPE
Notes
1 Line side factory installed 1/2-inch bolt provisions on 1-3/4-inch hole centers for two-hole compression lugs (lugs furnished by others).
2 Load side factory installed Burndy, two-hole, short barrel compression lugs suitable for copper wire only.
4
4
3 Requires 45-inch (1143.0 mm) wide enclosure.
4 Load side factory installed 3/8-inch bolt provisions for 1-hole compression lugs (lugs furnished by others).
5 Line and load side factory installed 1/2-inch bolt provisions on 1-3/4-inch hole centers for two-hole compression lugs (lugs furnished by others).
4
4
4
4
4
Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com V2-T4-35
4.6 Switchboards
Roll-Up Generator Termination Box
Dimensions
4 Approximate Dimensions in Inches (mm)
4
Enclosure
4 Rear Anchor Locations (8)
Use 0.5 (12.7) Diameter
4 6.00
(152.4)
6.00
(152.4) Grade 6 (Min.) Anchor Bolts
1.75 That Extend a Minimum of
D
4 (44.5) 0.75 (19.1) Above Finished Grade
4
25.75
4 14.50
(654.1)
(609.6)
4 6.00
2.75
(69.9)
(152.4) (2)
4
4.75
(120.7)
4
B C
5.25 3.25 1.75
(133.4) A (82.6) (44.5) (2)
4 Front
4 Termination/Lug Landing
4 78.00
(1981.2)
4.00 (101.6)
(Typical All Phases,
Neutral and Ground)
4
64.75
4 (1644.7)
56.50
4 (1435.1)
48.25
4 (1225.6) Punch Pattern on
Bus Varies Based on
4
40.00
(1016.0) Terminal Selection
35.00
4
(889.0)
4
20.00
4 (508.0)
4
4 0.00
(0.0)
0.00 A
4 (0.0)
4 45.00 (1143.0) 45.00 (1143.0) 18.25 (463.6) 18.00 (457.2) 28.50 (723.9) 45.00 (1143.0) 45.00 (1143.0)
Note
4 1 Conduit landing surface will be 20.00 (508.0) above finished grade.
4
V2-T4-36 Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com
Switchboards
Power Xpert Multipoint Metering Switchboard
4.7
Contents
Power Xpert Multipoint Metering Switchboard
Description Page
4
Power Xpert Multipoint Meter 4
Features, Benefits and Functions . . . . . . . . . . . V2-T4-38
Standards and Certifications . . . . . . . . . . . . . . V2-T4-38 4
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V2-T4-38
Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V2-T4-38 4
4
4
4
4
4
4
Power Xpert Multipoint Metering Switchboard 4
Overview Product Description Application Description 4
Allocation of energy Eatons Power Xpert Multipoint Using Eatons Power Xpert With energy cost on the rise,
consumption in a residential Meter can provide accurate Multipoint Metering it is vital to proactively monitor 4
or commercial application is a information of consumed Switchboard design, multiple and conserve electrical
tremendous task for a
property owner, management
energy for monthly involving
statements. Using the Power
tenant submetering has never
been easier. The Power Xpert
energy. Documentations of
electrical energy usage can
4
firm or electrical energy
manager. Eatons Power
Xpert Multipoint Meter for
utility allocation maximizes
Multipoint Metering
Switchboard combines the
promote energy conservation
for tenants or business 4
Xpert Multipoint Meter low- revenue by effectively Power Xpert Multi-Point departments. When the
cost solution can assist in measuring, allocating and Meter and Eatons PRL4, need for accurate energy 4
allocation or direct billing of recovering utility expenditures. PRLC or Integrated Facility consumption information
consumed energy. The
Power Xpert Multipoint
The Power Xpert Multipoint
Meter solution can interface
System (IFS)
to provide a space-saving,
for monthly tenant invoicing
arises, use Eatons Power
4
Meter provides a cost-
effective energy tabulation
with a third-party utility
allocation service and offers
cost-effective energy
tabulation system for
Xpert Multipoint Metering
Switchboard solution.
4
system for residential or the following advantages: residential or commercial
commercial metering metering installations. Using the Power Xpert 4
installations, including:
Purchase energy at bulk Multipoint Meter for utility
High-rise buildings
rates while charging
consumer rates
allocation maximizes revenue
by effectively measuring,
4
4
Universities and campuses Capitalize on naturally allocating and recovering utility
Office buildings variable tenant loads by expenditures. The Power
purchasing energy at a Xpert Multipoint Meter,
Apartment and
condominium complexes lower coinciding load using Eatons cost-allocation 4
Capture and allocate software or a third-party billing
Shopping malls
common area software, can generate single-
rate or multi-rate billing.
4
Airports maintenance cost
Promote tenant retention 4
with accurate and
defensible billing 4
Eliminate subsidization of
other tenants 4
4
4
4
4
Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com V2-T4-37
4.7 Switchboards
Power Xpert Multipoint Metering Switchboard
4
4
4
4
4
4
4
4
4
4
4
4
V2-T4-38 Volume 2Commercial Distribution CA08100003EOctober 2017 www.eaton.com