13.8Kv Automatic Bus Transfer Scheme Panel +abts: A EA-381674 P HA556 3-1313003.05 4400004657
13.8Kv Automatic Bus Transfer Scheme Panel +abts: A EA-381674 P HA556 3-1313003.05 4400004657
13.8Kv Automatic Bus Transfer Scheme Panel +abts: A EA-381674 P HA556 3-1313003.05 4400004657
A of
HA556 EA-381674 P 3-1313003.05 4400004657 3 4 5 6 7
03 NOTES
REV. NO. SHEET NO. DRAWING NUMBER PLANT NO. INDEX JOB ORDER NO. CONTRACT NO.
OW NER.
1 2
13.8kV AUTOMATIC BUS TRANSFER SCHEME PANEL +ABTS
SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION
TS
OF I
FUSE / LINK SWITCHING DEVICE WITH MANUAL OPERATION
CONSENT
A A
ELEMENT WITH STATIC NEGATED OUTPUT RESISTOR AND WITH AUTOMATIC RESET BELL, BUZZER
TTEN
AND WITH NON-AUTOMATIC RESET SIREN , HORN
ELEMENT WITH DYNAMIC INPUT
THE W RI
CURRENT TRANSFORMER
RESISTOR WITH PRESET ADJUSTMENT
- SINGLE LINE DIAGRAM
THOUT
CURRENT TRANSFORMER
WI
SEMICONDUCTOR DIODE USED AS A
- TRIPOLAR DRAWING ELEMENT WITH INHIBITING INPUT CAPACITIVE DEVICE TERMINAL BLOCK - KNIFE TYPE
DOCUMENT
RELAY COIL
S
THI
- SINGLE LINE DIAGRAM SLOW OPERATING RELAY COIL
FROM
ELEMENT WITH INPUT WHICH DOES NOT CARRY
ANY LOGIC INFORMATION
POWER SOCKET
WINDING
SLOW RELEASING RELAY COIL
NED
CHANGE-OVER CONTACT, BREAK
SHALL BE OBTAI
X ELEMENT WITH POSTPONED OUTPUT
BEFORE MAKE
VOLTAGE TRANSFORMER
RELAY WITH MAKE CONTACT VT TEST SWITCH
- TRIPOLAR DRAWING
PART
VOLTMETER
BREAK CONTACT WHICH IS LATE WHEN CONTROL TEST SWITCH
RELAY WITH CHANGE-OVER CONTACT
>1 OPERATING AND EARLY WHEN RELEASING
OR-ELEMENT WITH TWO INPUTS
N
I
C C
A
FULL OR
AMMETER
N
W WATTMETER
I
INPUTS AND THRESHOLD VALUE 2 DELAYED WHEN OPERATING
MAKE CONTACT DELAYED WHEN OPERATING
ON
REPRODUCTI
REFERENCE DRAWINGS
Var VARMETER BREAK CONTACT DELAYED WHEN RELEASING
DRAWING TITLE DRAWING NO.
=2
"2 AND ONLY 2" RELAY WITH MAKE CONTACT, DRAWING CONTROL SHEET EE-381610
ELEMENT WITH THREE INPUTS FOR DELAYED WHEN RELEASING
RELAY & METERING ONE LINE DIAGRAM EA-381356
MAKE CONTACT DELAYED WHEN OPERATING
NO
PF POWER FACTOR METER AND RELEASING
d SA
=1
onalGri
D D
EXCLUSIVE OR-ELEMENT WITH THREE INPUTS
POSITION INDICATOR MAIN CONTACT OF A SWITCH DISCONNECTOR RELAY WITH MAKE CONTACT, DELAYED
WHEN OPERATING AND RELEASING
OF Nati
MAIN CONTACT OF A DISCONNECTOR
=
SYNCHROSCOPE LOGIC IDENTITY ELEMENT WITH THREE INPUTS
N
HEREI
MAKE CONTACT DELAYED WHEN RELEASING
E E
h HOUR METER
&
NED
NAND ELEMENT WITH TWO INPUTS
TWO MECHANICAL LINKS CROSSING
A 2016-01-11 AES ISSUED FOR DETAILED DESIGN KAM AS AS
CONTAI
WITHOUT CONNECTION
REV. DATE BY CHKD. CERT. APPD.
DESCRIPTION
NO.
Wh WATT-HOUR METER
DRAWING COMPLETION CERTIFICATE (DCC):
>1 NOR ELEMENT WITH TWO INPUTS
ON
JUNCTION OF MECHANICAL LINKS
NFORMATI
WATT-HOUR METER FOR ENERGY FROM
Wh A BUSBAR SYSTEM X
BISTABLE ELEMENT AUTOMATIC RESET
THE I
SIGNALLING LAMP
DINAKAR KAMAL NONE
Y DRAWN BY CHECKED BY SCALE:
2016-01-11
DATE STARTED DATE COMPLETED
AND
ELEMENT WITH STATIC INPUT OPR'G. DEPT. ENG. DEPT.
FRAME CONNECTION NON-AUTOMATIC RESET
F
ELECTRO-MECHANICAL POSITION INDICATOR
POSITION F THIS DRAWING IS NOT TO BE USED FOR CERTIFIED
NG
WITH ONE DE-ENERGIZED AND TWO OPERATED CONSTRUCTION OR FOR ORDERING
DRAW I
MATERIAL UNTIL CERTIFIED AND DATED BY DATE
EARTH CONNECTION
ELEMENT WITH STATIC NEGATED INPUT GRAPHICAL SYMBOLS FOR DIAGRAMS +ABTS
13.8kV AUTOMATIC BUS TRANSFER SCHEME PANEL
S
THI
AL-UQAIR 115/13.8kV SUBSTATION-B
MANUFACTURER/VENDOR NAME
AL-UQAIR SAUDI ARABIA
ALFANAR ELECTRICAL SYSTEMS CONTRACT NO. JOB ORDER NO. INDEX PLANT NO. DRAWING NUMBER SHEET NO. REV. NO.
DRAWING NO. SHEET NO. REV. NO.
03
EA-381674 03 of 13 A 1 2 3 4 5 6 7
4400004657 3-1313003.05 P HA556 EA-381674 of
13 A
NG-A (2012/01)