Pulsar Series

Eaton EX
700/1000/1500/2200/3000 VA

Double conversion (on-line)

Maximum availability
• Topology: double conversion on-line UPS with automatic
by-pass and power factor correction
• Powershare: the Eaton EX output sockets are individually
controlled to provide load-shedding to maximise the backup
time and provide remote reboot and sequential start-up as
standard
• Continuous power supply: Hot swappable batteries.
The HotSwap MBP (Maintenance By-Pass) module allows the
UPS to be replaced without interrupting the power supply
• Long backup times: 1 to 4 EXB battery units can be added
Eaton EX 1500 to the Eaton EX. The Eaton EX 3000XL has a built-in super
charger for extra long backup times

Minimum total cost of ownership


• Easy operation: the LCD gives you access to a wide range
of measurements and set-up menus
• Remote supervision: the Eaton software suite offers a wide
range of communication option including: SNMP and HTML,
ModBus/JBus and relay outputs

Total flexibility
Eaton EX has unmatched Flexibility.
Eaton EX Rack/Tower versatility • Format: EX 700 to 1500 are available in tower format or
RT2U convertible rack/tower format (compatible with
short-depth rack). EX 2200 & 3000 are available in RT2U
format (optimised for rack mounting) or RT3U (for tower or
Ideal protection for: short-depth racks)
• Servers, data storage and network equipment
• Connections: with FlexPDU and HotSwap MBP, the RT2U
• Telephony - VoIP and RT3U models can be connected by sockets or terminal
• Medical equipment - Industrial processes blocks.
They can be installed as required, on the side or on top of
the unit
• Compatible with high power factor loads: Eaton EX is
rated for 0.9 power factor (700 VA/630 W, 1000 VA/900 W,
1500 VA/1350 W, 2200 VA/1980 W and 3000 VA/2700 W)
• Communication: the EX includes both serial and USB ports,
plus remote On/Off connector and an extra slot for optional
communication cards. The UPS comes with a complete
Eaton software suite.
Eaton EX UPS

LCD Multilingual display 1 USB port + 1 serial port + remote ON/OFF and
- 6 languages, emergency stop inputs.
- displays measurements, EXB battery unit connector.
- displays alarms,
- access to control and set-up menus. EXB units recognised automatically.
Panel for batteries replacement (Hot 8 IEC 10A sockets, including 4 Powershare pro-
swappable) grammable sockets and 1 IEC 16A socket.
Communication card slot.
Mountings for HotSwap MBP and FlexPDU.
Eaton EX 3000

TECHNICAL SPECIFICATIONS 700 1000 - 1000 RT2U 1500 - 1500 RT2U 2200 3000 - 3000 XL
Rating (VA/W) 700 VA / 630 W 1000 VA / 900 W (1) 1500 VA / 1350 W (1) 2200 VA / 1980 W 3000 VA / 2700 W (1)
Format Mini tower Mini tower or RT2U (tower/rack 2U) RT2U (tower/rack 2U) and RT3U (tower/rack 3U)
Electrical characteristics
Architecture On-line double conversion with automatic by-pass and power factor correction
Input voltage and frequency ranges 100/120/140/160 V to 284V - 40 to 70 Hz 100/120/160/184 V to 284V - 40 to 70 Hz
for load level <20% / <33% / <66% / >=66% of
without using batteries for load level <20% / <33% / <66% / >=66% of rated output rated output
Output voltage and frequency 230 V (adjustable to 200/208/220/240/250 V), 50/60 Hz auto-select or 230 V (adjustable to 200/208/220/240 V),
frequency converter mode (2) 50/60 Hz auto-select or frequency converter mode
Connections
Input 1 IEC C14 (10A) socket 1 IEC C20 (16A) or terminal block on HotSwap
MBP HW (Hard-Wired)
Outputs 6 IEC C13 (10A) sockets 8 IEC C13 (10A) sockets + 1 IEC C19 (16A) socket
Remotely controlled Powershare sockets 2 independent groups: 2 + 1 IEC C13 (10A) sockets 2 groups of 2 x IEC C13 (10A) on Eaton EX
Additional outputs with
4 FR/Schuko sockets or 3 BS sockets or 6 IEC 10A sockets or terminal blocks (HW version)
HotSwap MBP FR/DIN/BS/IEC/HW
Additional outputs with
8 FR/Schuko sockets or 6 BS sockets or 12 IEC 10A sockets
FlexPDU FR/DIN/BS/IEC
Battery
Typical backup times for 50 and 70% load (5) except for Eaton EX 3000 XL (4)
EX 16 min / 10 min 18 min / 12 min 13 min / 9 min 17 min / 12 min 15 min / 10 min
EX + 1 EXB / 75 min / 50 min 50 min / 35 min 85 min / 60 min 60 min / 40 min
EX + 4 EXB / 250 min / 200 min 180 min / 120 min 285 min / 200 min 190 min / 150 min
Battery management Automatic weekly test (period adjustable using LCD display or in software supplied), automatic recognition
of external battery units => continuous maximisation of backup time + deep discharge protection
Interfaces
Indicators and display 3 LEDS + adjustable multilingual display: display of measurements, access to control and set-up menus
Communication ports 1 USB port + 1 RS232 serial port and relay contacts (3) + 1 mini terminal block for remote ON/OFF and emergency stop
Communications card slots 1 slot for NMC Minislot card (included in Netpack version) or NMC ModBus/JBus or MC Contacts/Serial
Operating conditions, standards and approvals
Operating temperature noise level 0°C to 40°C continuous, 45 dBA
Performance - Safety - EMC IEC/EN 62 040-1, IEC/EN 62 040-2, IEC/EN 62 040-3 (VFI-SS-113), IEC/EN 60 950-1 (RD)
Approvals CE, TüV GS, CB report, cTüV-US CE, TüV, CB Report, UL CE, TüV, CB Report, UL
Dimensions (H x W x D) / Weight
EX 242 x 153 x 440 mm / 242 x 153 x 440 mm / 242 x 153 x 490 mm / 440 x 131 x 490 mm (6) /
12.5 kg 15 kg 18 kg 30 kg (3000 XL = 18 kg)
86.5 x 438 x 483 mm / 86.5 x 438 x 483 mm /
EX (RT2U format) / 86 x 440 x 640 mm / 31 kg
18 kg 20.5 kg
EX EXB / 242 x 153 x 440 mm / 21 kg 440 x 131 x 490 mm (6)
EX EXB (RT2U format) / 86.5 x 438 x 483 mm / 24.5 kg / /
Customer Service & Support
2 years warranty Standard product exchange, including the battery
Warranty+ Optional 3-years warranty (depending on the country please visit www.eaton.com/powerquality)
1: Maximum rating with EXB battery units: Eaton EX 1000 = 800 W, Eaton EX 1500 =1200 W and Eaton EX 3000=2400W. 2: Derated by 15% when used as a frequency converter. 3: USB and RS232 serial
ports cannot be used simultaneously. 4: Except Eaton EX 3000 XL: UPS with high speed charger, without built-in batteries, for custom configurations: ask us for details. 5: Runtimes are shown at 0.7
power factor. Backup times are approximate and may vary with equipment, configuration, battery age, temperature, etc. 6: compatible with 600 mm deep rack

Part Numbers 700 1000 1500 2200 3000


EX 68 180 68 181 68 183 68 400 68 402 - XL: 68 404
EX (RT2U format, includes rack kit) / 68 182 68 184 68 401 68 403
EX HotSwap (RT3U format, includes / / / FR: 68406 DIN: 68407 BS: FR: 68412 DIN: 68413 BS:
rack kit + HotSwap MBP) 68408 68414
IEC: 68409 HW: 68410 IEC: 68415 HW: 68416
EX Netpack (RT2U format, includes
/ / / 68 411 68 417
rack kit and NMC card)
EX EXB / 68 185 68 185 / /
EX EXB (RT2U format, includes rack kit) / 68 186 68 186 / /
EX EXB (RT3U format, includes rack kit) / / / 68 405 68 405
EX Rack Kit 2U/3U / / / 68 441 68 441