Gea Bock 96023 GB
Gea Bock 96023 GB
Gea Bock 96023 GB
This makes it all the more important that you have a partner – in GEA Refrigeration
Technologies – that has learned to master refrigeration from A to Z. And all of this since
1896, when Willem Grasso founded his refrigeration division. From this history of GEA
Refrigeration Technologies, you will profit in the form of technical expertise and top
sector know-how.
But we all live in the present and think about the future. We ponder a future in which
more and more processes need energy around the world, and fewer natural resources are
available. As a result, we have taken it as our goal to create solutions that are not only long-
life and cost-effective, but also energy-saving and environment-protecting. We feel obliga-
ted to sustainability in many respects. Our objective is to produce longlife and material-
saving products over the long run – as well as products that use environmentally benign
refrigerants. And we aim to produce efficiently. But our responsibility does not end at
the factory gate. As a result, we take great pains to ensure that our systems are energy-
efficient and that they protect the climate. With GEA Refrigeration Technologies, you can
also count on optimal economy: saving energy indeed means reducing money spent for
energy. At the same time, you protect the environment. Thanks to our refrigeration tech-
nology, your processes will run more economically and more ecologically. To maintain our
standard of living and to assure quality of life for future generations as well.
Our claim of combining economy with saving natural resources is reflected in all com-
ponents of our company, such as the following: compressors, chillers, heat pumps, ice
machines, fittings and valves, control systems, and many, many more. You can find proof
of the above throughout the world. Our international corporate network – and above all
our reference projects – are spread all over the globe.
F single-stage compressors I 1
F compressors for NH3 I 2
FDK compressor units for direct drive I 3
Service made by GEA Bock I 4
Disclaimer
This catalogue has been produced for you with the greatest of care. Nevertheless it The details are provided as unbinding general information and cannot substitute de-
is not possible to rule out mistakes completely. In such cases we cannot assume any tailed, individual consultation. Reprints even only of excerpts only allowed with the
liability. The contents correspond to the status on going to print. Deviations cannot explicit approval of GEA Bock GmbH. © GEA Bock GmbH 2011
be ruled out because of the ongoing development process for our products.
Available versions
Single-stage compressors 6 model sizes with 8 capacity stages - from 10,5 to 178,4 m³/h (1450 rpm)
Compressors for NH3 6 model sizes with 8 capacity stages - from 10,5 to 178,4 m³/h (1450 rpm)
Compressor units for direct drive 5 model sizes with 7 capacity stages - from 20,3 to 178,4 m³/h (1450 rpm)
The Bock HG (Hermetic Gas-cooled) range of semi-hermetic compressors offers traditional suction gas-cooled compressor state of the art
technology. These compressors of the highest quality standard excel in their running comfort, easy maintenance, efficiency and reliability.
Suitable as standard for conventional or chlorine-free HFC refrigerants.
The HA (Hermetic Air-cooled) range, specially engineered by Bock, exists for deep-freezing applications, in particular for use with refrige-
rants R22 and R404A.
Available versions
Single-stage compressors 8 model sizes with 26 capacity stages - from 5,4 to 279,8 m³/h (50 Hz)
CO2 compressors subcritical 4 model sizes with 14 capacity stages - from 3,6 to 48,2 m³/h (50 Hz)
CO2 compressors transcritical 3 model sizes with 11 capacity stages - from 2,7 to 20,1 m³/h (50 Hz)
R134a compressors 2 model sizes with 6 capacity stages - from 62,9 to 122,4 m³/h (50 Hz)
R407C compressors 1 model sizes with 4 capacity stages - from 18,8 to 33,1 m³/h (50 Hz)
R410A compressors 4 model sizes with 11 capacity stages - from 5,4 to 40,5 m³/h (50 Hz)
ATEX compressors 6 model sizes with 20 capacity stages - from 5,4 to 122,4 m³/h (50 Hz)
HC compressors 3 model sizes with 7 capacity stages - from 18,8 to 56,6 m³/h (50 Hz)
Aluminium compressors 2 model sizes with 10 capacity stages - from 11,1 to 66,1 m³/h (50 Hz)
2-pole compressors 1 model sizes with 3 capacity stages - from 44,3 to 66,1 m³/h (50 Hz)
Two-stage compressors 1 model sizes with 3 capacity stages - from (LP/HP) 93,7/46,9 to 122,4/61,2 m³/h (50 Hz)
Duplex compressors 7 model sizes with 23 capacity stages - from 5,4 to 367,2 m³/h (50 Hz)
Compressor units with receiver 7 model sizes with 23 capacity stages - from 5,4 to 183,6 m³/h (50 Hz)
Condenser units air-cooled 4 model sizes with 14 capacity stages - from 5,4 to 56,6 m³/h (50 Hz)
Vehicle compressors FK
Bock vehicle compressors of the FK range are the result of many years of experience in the domain of mobile cooling systems. Especially
for bus and coach air-conditioning systems, they are among the standard units used by all well-known manufacturers, while also being well
established in the domain of transport refrigeration systems and in other mobile and stationary refrigeration systems.
The unsurpassed light, compact, robust design and wide r.p.m. range are only some of the outstanding features of this unique product range
of two, four and six cylinder compressors.
A wide variety of designs can be tailored to suit individual requirements.
The so-called K version is a special innovation with a unique valve plate system for maximum requirements in bus and coach airconditio-
ning systems.
Available versions
Compressors for bus and railway air-conditioning 4 model sizes with 16 capacity stages - from 118 to 976 cm³
Compressors for transport refrigeration and other applications 4 model sizes with 14 capacity stages - from 118 to 776 cm³
At a glance 8
Operating limits and performance data 13
Technical data 22
Dimensions and connections 23
Scope of supply and accessories 32
° Bock open type compressors F
At a glance
The F model series provides modern open type compressors for separate drive systems using V belts or direct couplings. Load transfer
through a V pair. Virtually all drive capacity requirements can be met.
Type key
F X 14 / 1166
Swept volume 2)
Size
1) X - Ester oil filling (HFC refrigerant, e.g. R134a, R407C)
Ester oil filling 1)
2) Indication only at F14, F16
Series
200
F16
F14
100
F5
displacement m³/h
F4
F3
F2
5 5 0 0
21 33 66 46 16 36 75 05
-1 -2 -4 -8 -1 -1 -1 -2
... ... ... ... ... ... ... ...
2 cylinder 2 cylinder 4 cylinder 4 cylinder 4 cylinder 6 cylinder
1
2
3
4
-- Compact construction
-- Robust and easy to handle
-- Suitable for v-belt or coupling drive
-- Large number of applications with a wide r.p.m. range
-- Naturally with oil pump lubrication
Universal
-- e.g. R134a, R404A, R507, R407C, R22
-- One
compressor design for all conventional refrigerants,
for air conditioning applications, normal or deep-freezing.
Maximum permissible operating pressure: 28 bar
-- Compressor designs for NH3
-- Compressor designs for CO2 on request
6-cylinder engine
-- Globally proven valve design with one-sided fixed tongue fins, intake side and pressure side
(F 14, F 16 intake side formed as ring fins)
-- Valves made out of high-quality, impact-resistant spring steel
-- Conical shaft end for safe force transmission and exact installation of the drive elements
-- Drive via v-belt or coupling, with all the conventional drive sources
(electric motors, combustible motors, hydraulic motors, etc.)
Unlimited
application range
Supplementary cooling or
reduced suction gas temperature
1)
LP = low pressure HP = high pressure
1
2
3
R134a Notes
4
Limits of application
1,4
Performance data
1,2
1,0
Performance specifications for the R134a are based on 25°C
0,8
suction gas temperatures without liquid subcooling. Compressor
0,6
speed 1450 rpm.
Cooling capacity Q0
0,4
The values can be stated to judge the overall performance at Power required P
other speed with the help of the calculation factors below. 0,2
Factor
0,0
500 750 1000 1250 1500 1800
For additional technical data for other operating points see
Compressor speed (rpm)
GEA Bock software.
30
P
Q
25,52
145822
24,65
133308
23,73
121602
21,76
100486
19,70
82215
17,63
66533
15,65
53180
13,82
41898
12,24
32429
10,99
24515
10,15
17897 2
P 13,45 14,16 14,68 15,22 15,18 14,67 13,78 12,63 11,33 9,99 8,70
Q
3
130423 119010 108353 89177 72636 58473 46429 36247 27667 20431 14282
40
P 19,32 19,51 19,54 19,18 18,37 17,19 15,76 14,19 12,58 11,04 9,68
Q 114566 104272 94681 77480 62705 50097 39399 30351 22696 16175 10530
FX16/1751 50
P 24,50 24,21 23,79 22,63 21,12 19,37 17,48 15,57 13,74 12,09 10,74
60
Q
P
98365
28,95
89208
28,23
80702
27,40
65512
25,52
52538
23,41
41521
21,17
32203
18,91
24326
16,74
17631
14,78
11861
13,11
6756
11,86
4
Q 81937 73935 66531 53388 42250 32860 24959 18288 12589 7605 3076
70
P 32,65 31,53 30,35 27,83 25,19 22,55 20,01 17,68 15,66 14,06 12,99
Q 170924 156256 142534 117783 96368 77986 62334 49110 38011 28735 20977
30
P 15,77 16,60 17,21 17,84 17,80 17,19 16,15 14,81 13,29 11,71 10,20
Q 152875 139497 127005 104528 85140 68539 54422 42486 32429 23948 16740
40
P 22,65 22,87 22,90 22,49 21,53 20,15 18,47 16,63 14,75 12,94 11,35
Q 134288 122222 110980 90818 73499 58721 46181 35575 26602 18959 12342
FX16/2051 50
P 28,71 28,37 27,89 26,52 24,75 22,70 20,49 18,25 16,10 14,17 12,59
Q 115298 104565 94594 76789 61582 48668 37746 28513 20666 13902 7919
60
P 33,93 33,08 32,12 29,91 27,43 24,81 22,17 19,63 17,32 15,37 13,90
Q 96042 86662 77983 62578 49523 38517 29255 21436 14757 8914 3606
70
P 38,27 36,96 35,57 32,62 29,53 26,44 23,46 20,72 18,35 16,48 15,22
Unlimited
application range
Supplementary cooling or
reduced suction gas temperature
1)
LP = low pressure HP = high pressure
R404A/R507 Notes
Limits of application
1,4
Performance data
1,2
1,0
Performance specifications for R404A/R507 are based on 20°C
0,8
suction gas temperatures without liquid subcooling. Compressor
0,6
speed 1450 rpm. Cooling capacity Q0
0,4
The values can be stated to judge the overall performance at Power required P
0,2
other speed with the help of the calculation factors below.
Factor
0,0
500 750 1000 1250 1500 1800
For additional technical data for other operating points see Compressor speed (rpm)
GEA Bock software.
Unlimited
application range
Supplementary cooling or
reduced suction gas temperature
1)
LP = low pressure HP = high pressure
R407C Notes
Limits of application
points. 1,8
1,6
1,2
Performance specifications for R407C are based on 25°C suction 1,0
gas temperatures without liquid subcooling. Compressor speed 0,8
1450 rpm. 0,6
The values can be stated to judge the overall performance at Cooling capacity Q0
0,4
Power required P
other speed with the help of the calculation factors below.
0,2
Factor
0,0
For additional technical data for other operating points see 500 750 1000 1250 1500 1800
GEA Bock software. Compressor speed (rpm)
FX5 40
P
Q
9,77
88680
10,35
81100
10,78
74013
11,25
61236
11,27
50182
10,94
40682
10,33
32568
9,53
25671
8,64
19823
7,73
14856 2
P 14,48 14,64 14,68 14,44 13,85 13,00 11,97 10,85 9,72 8,67
3
Q 77827 71017 64665 53248 43410 34982 27794 21679 16469 11995
50
P 18,57 18,36 18,05 17,19 16,08 14,79 13,42 12,06 10,78 9,68
Q 136367 124912 114186 94805 77993 63517 51147 40650 31796 24352
30
P 13,45 14,24 14,83 15,47 15,51 15,05 14,21 13,12 11,88 10,63
FX14/1166 40
Q
P
122008 111579 101830 84252 69043 55973 44809 35320 27274 20439 4
19,92 20,14 20,20 19,87 19,06 17,89 16,47 14,93 13,37 11,93
Q 107077 97708 88968 73262 59727 48130 38241 29828 22659 16503
50
P 25,55 25,26 24,84 23,65 22,12 20,35 18,47 16,59 14,84 13,32
Q 160037 146594 134006 111261 91531 74543 60025 47706 37314 28578
30
P 15,78 16,71 17,40 18,16 18,20 17,66 16,68 15,39 13,95 12,47
Q 143185 130946 119504 98876 81028 65689 52587 41450 32007 23987
FX14/1366 40
P 23,38 23,64 23,70 23,32 22,37 20,99 19,33 17,52 15,69 14,00
Q 125661 114666 104410 85978 70093 56484 44878 35005 26592 19367
50
P 29,99 29,64 29,15 27,76 25,96 23,88 21,68 19,47 17,41 15,63
Q 204684 187491 171392 142302 117067 95339 76771 61015 47725 36551
30
P 20,19 21,37 22,25 23,22 23,28 22,58 21,33 19,69 17,84 15,95
Q 183133 167479 152845 126461 103634 84015 67258 53015 40937 30679
FX16/1751 40
P 29,91 30,23 30,32 29,82 28,61 26,85 24,72 22,40 20,07 17,90
Q 160720 146658 133540 109966 89649 72243 57399 44771 34010 24770
50
P 38,35 37,92 37,28 35,50 33,20 30,55 27,72 24,90 22,27 19,99
Q 239918 219766 200895 166798 137219 111751 89987 71519 55940 42843
30
P 23,66 25,05 26,08 27,22 27,28 26,47 25,00 23,08 20,91 18,70
Q 214657 196309 179156 148231 121474 98478 78836 62141 47985 35960
FX16/2051 40
P 35,05 35,44 35,53 34,96 33,53 31,47 28,98 26,26 23,53 20,99
Q 188386 171903 156528 128895 105081 84679 67280 52478 39865 29034
50
P 44,95 44,44 43,70 41,62 38,92 35,81 32,50 29,19 26,10 23,43
Unlimited
application range
Supplementary cooling or
reduced suction gas temperature
1)
LP = low pressure HP = high pressure
R22 Notes
Limits of application
1,4
Performance data 1,2
1,0
Performance specifications for R22 are based on 25°C suction
0,8
gas temperatures without liquid subcooling. Compressor speed
0,6
1450 rpm. Cooling capacity Q0
0,4
The values can be stated to judge the overall performance at Power required P
0,2
Factor
F5 40
P
Q
10,45
80069
11,18
67422
11,51
56302
11,49
46589
11,19
38166
10,67
30915
10,00
24716
9,24
19452
8,46
15004
7,71
11254
7,06
8084 2
P 14,40 14,57 14,39 13,93 13,25 12,41 11,48 10,52 9,59 8,76 8,10
72345 60673 50449 41554 33871 27281 21665 16905
3
Q
50
P 18,14 17,77 17,11 16,23 15,18 14,05 12,88 11,74
Q 120460 101761 85270 70824 58260 47416 38128 30234 23571 17976 13286
30
P 14,38 15,39 15,83 15,80 15,39 14,68 13,76 12,71 11,63 10,61 9,72
F14/1166 40
Q
P
110163
19,82
92762
20,05
77462
19,80
64100
19,16
52511
18,22
42534
17,07
34006
15,79
26763
14,47
20644
13,20
15484
12,06
11121
11,14
4
Q 99536 83477 69410 57173 46602 37535 29808 23259
50
P 24,96 24,45 23,54 22,32 20,89 19,33 17,72 16,15
Q 141369 119424 100070 83117 68372 55646 44746 35482 27662 21096 15592
30
P 16,88 18,06 18,58 18,55 18,06 17,23 16,15 14,92 13,65 12,45 11,40
Q 129284 108863 90907 75225 61625 49917 39908 31409 24227 18172 13052
F14/1366 40
P 23,26 23,53 23,24 22,49 21,39 20,03 18,53 16,98 15,49 14,15 13,08
Q 116813 97966 81458 67096 54690 44049 34982 27296
50
P 29,29 28,69 27,62 26,20 24,52 22,68 20,79 18,96
Q 180811 152743 127990 106306 87448 71171 57230 45381 35380 26982 19942
30
P 21,58 23,09 23,76 23,72 23,10 22,03 20,65 19,08 17,46 15,92 14,59
Q 165353 139235 116270 96212 78818 63843 51042 40171 30986 23241 16693
F16/1751 40
P 29,74 30,09 29,72 28,76 27,35 25,62 23,70 21,72 19,81 18,10 16,73
Q 149402 125297 104183 85815 69948 56338 44741 34911
50
P 37,46 36,69 35,33 33,51 31,36 29,01 26,60 24,25
Q 211935 179036 150022 124606 102501 83422 67081 53193 41470 31626 23375
30
P 25,30 27,07 27,85 27,80 27,08 25,83 24,21 22,37 20,47 18,66 17,10
Q 193817 163203 136285 112775 92386 74833 59829 47086 36320 27242 19567
F16/2051 40
P 34,86 35,27 34,83 33,71 32,06 30,03 27,78 25,45 23,22 21,21 19,61
Q 175120 146867 122118 100588 81990 66037 52443 40921
50
P 43,91 43,01 41,41 39,28 36,76 34,00 31,17 28,42
F2
101
B
B1 DV
A1
B/L SV
A
ca.340
H/D1
310
195
X
1
123
4xØ9
K
2
114 77 134 F/G
3
15
ca.255 152
4
Shaft end
8xM6 Ø82
6xM5 Ø49
A4x6,5 DIN 6888
M8x22
1.5
Ø101 h8
Ø60
Ø25
Ø21,69
1:4
25
30
32,5
59
F3
135
118 B1 90
DV
B/L
A
A1
ca.400
SV
360
C/E
230
D/D1/H
X
K 135
4xØ9
17
F/G
130 96.5 175
ca.315 200
Shaft end
8xM8 Ø110
6xM5 Ø49
A4x6,5 DIN 6888
M8x22
1.3
Ø130 h8
Ø60
Ø25
Ø21,69
1:4
25
30
37
63
F4
ca.305
ca.240 L B1 B DV
SV
A1
ca.430
D
395
C/E
ca.200 H
X D1 K
170
1
F
2
130 4x 11 J1
3
25
ca.225 210
240
ca.455 4
Shaft end
8xM10 130
6xM8 72
40
90
1:5
50
54
100
F5
ca.355
B1 246
B
L
DV
SV
A
ca.465
A1
430
D
C/E
340 D1
X 170 H K
F
4xØ11 240 J1
25
Shaft end
8xM10 Ø150
6xM8 Ø72
A5x9 DIN 6888
M12x30
2
Ø170 h8
Ø90
Ø40
1:5
50
53
100
ca.510(560)
448(498)
B2
432(482)
H
D1 C
D E
P Y
1
180(230)
X
Y K
F
J1 2
290 121.5 4xø13.5 ÖV1 3
20
342 290
ca.530 320
4
Shaft end
12xM10 210
8xM8 111
A5x9 DIN 6888
M12x26
2
130 h8
50
1:5
50
53,5
94
ca.310
363 170 ca.515
SV
A1
DV B1
L B
C
ca.535 (585)
B2 B
470 (520)
452 (502)
A H
E
D D1 K
ca.260
200 (250)
X P Y
Y F
J1
290 143,5 4x 13,5
ÖV1
20
342 290
ca.580 320
Shaft end
12xM10 210
8xM8 111
A10x16 DIN 6888
M12x26
3,2
130 h8
60
1:5
50
57,5
115
View X,Y
Position view X:
F2, F3, F4, F5, F14, F16
4 hole oil sightglass
Position view Y:
F14, F16
Second oil sightglass can be attached as an option
(available as original equipment only) 4 x M6, 10 mm deep
1
2
3
4
Connection facilities
Bock adapter for oil level regulator, Bock adapter for oil-gas regulator,
fits the makes ESK, AC+R, CARLY. single design, 4 hole steel connector for
3 hole fastener on the side of the oil level regulator Pipe Ø 35 mm, fits all sightglass positions.
4 hole fastener on the side of the compressor 1 item per compressor required.
D
Connection oil pressure
- 1
/8 " NPTF 7
/16 " UNF 7
/16 " UNF 7
/16 " UNF 7
/16 " UNF
1
safety switch LP
D1
Connection oil return from 1
/8 " NPTF 1
/8 " NPTF 1
/8 " NPTF 1
/8 " NPTF 5
/8 " UNF 5
/8 " UNF
2
oil separator
E
Connection
- 1
/8 " NPTF 7
/16 " UNF 7
/16 " UNF 7
/16 " UNF 7
/16 " UNF
3
oil pressure gauge
4
F Oildrain R 3 /8 " M 22 x 1,5 M 22 x 1,5 M 22 x 1,5 M 26 x 1,5 M 26 x 1,5
Connection thermal
L 1
/8 " NPTF 1
/8 " NPTF 1
/8 " NPTF 1
/8 " NPTF 1
/8 " NPTF 1
/8 " NPTF
protection thermostat
1)
Oil sump heating optional
2)
Second sightglass can be attached,
Positioning view Y ( optional, available only as original equipment)
Oil filling:
F: FUCHS Reniso SP 46
FX: FUCHS Reniso Triton SE 55
Sight glass
Shaft seal with piece of tube Screw-in option for oil differential pressure switch Oil service valve
1 2 3
Sight glass Thermal protection thermostat Water-cooled cylinder covers Elevated base plate
7 8 9 10
At a glance 36
Operating limits and performance data 37
Technical data 40
Dimensions and connections 41
Scope of supply and accessories 48
° Bock open type compressors F NH3
At a glance
Type key
F 14 / 1166 NH3
Refrigerant
Swept volume 1) 1) Indication only at F14, F16
Size
Series
F3 NH3 20,3
F4 NH3 40,5
F5 NH3 73,7
NH3 Limits of application F2 NH3, F3 NH3, F4 NH3, F5 NH3, F14 NH3, F16 NH3
Unlimited
application range
S upplementary cooling necessary
(e.g. water-cooled cylinder covers)
1)
LP = low pressure HP = high pressure
1
2
NH3 Notes
3
Limits of application Operation with NH3 and R723
4
Compressor operation is possible within the examples in the diagram NH3 is a refrigerant traditionally used in industry and largescale refri-
showing the limitations of use. The meaning of the surfaces marked geration system, as NH3 has considerably more vapouration heat and
in colour are to be observed. Limiting areas should not be selected for thus a larger volumetric refrigerating capacity than most F gases. That
layout or continuous operating points. is why operating NH3 at small capacities (< 30 KW, e.g. in the commer-
cial sector) can be problematic.
Performance data NH3 has a high adiabatic index and thus significantly higher pressure
gas temperatures. On one hand, this greatly limits the application ran-
Performance specifications for the NH3 are based on 10 K suction gas
ge with regard to low temperatures; on the other hand, this requires
overheating without liquid subcooling. Compressor speed 1450 rpm.
thermally highly stable refrigeration oils. Nonsoluable mineral oils with
The values can be stated to judge the overall performance at other
a viscosity of 68 are used as standard - Fuchs Reniso KC 68. Flooded
speed with the help of the calculation factors below.
operation is customary.
In the case of dry expansion, please note that overheating results in
For additional technical data for other operating points see GEA Bock
higher hot-gas temperatures. That is why only low temperature condi-
software.
tions are possible or multi-stage refrigeration systems are necessary.
2,0 The use of mixable polyalkylene glycol oils (PAG) with dry expansi-
1,8 on must be viewed critically due to the moisture problem (refrigerant
1,6 NH3 < 400 ppm and PAG oil < 250 ppm must be run extremely dry!)
1,4 For systems with plate heat exchangers, for example, the small pipe
1,2
dimensions can result in oil return problems. Polyalphaolefin oils (PAO),
e.g. Fuchs Reniso Synth 68, have proven themselves in the first applica-
1,0
tions. They are currently being tested in the field.
0,8
So far there has not yet been enough experience with R723 (60 %
0,6
NH3 + 40 % Dimethylether) to recommend its use. For R723, we also
0,4 Cooling capacity Q0
recommend using Reniso Synth 68.
0,2 Power required P
Factor
Please consult our technical service if you have any questions about the
0,0
500 750 1000 1250 1500 current status of development.
Compressor speed (rpm)
10
P
Q
33,90
33,14 31,67 29,56
138257
18,86
110659
18,26
86991
17,33
66970
16,17
50313
14,88
36738
13,56
25960
12,32
17697
11,25
2
P
Q 195548 159276 127655 100402 77233 57866 42018 29405 19745 12755
20
P
Q
20,99 21,35
266615 220692 180141 144678
21,14
114020
20,44
87885
19,38
65988
18,04
48049
16,52
33782
14,94
22905
13,38 11,95 3
F16/1751 NH3 60
P 24,32 25,72 26,29 26,14 25,37 24,08 22,37 20,34 18,09 15,72
40
Q
P
246823 202173 163049 129168
33,17 33,64 33,24 32,07
100247
30,24
76002
27,83
56152
24,97
4
Q 226696 184092 147168 115642
50
P 43,37 42,40 40,51 37,82
Q 162095 129738 101990 78517 58988 43072 30436 20749
10 22,11 21,40 20,31 18,95 17,44 15,90 14,44 13,19
P
Q 229263 186737 149664 117712 90549 67843 49262 34475 23150 14954
20 24,61 25,03 24,78 23,97 22,72 21,15 19,37 17,51 15,69 14,02
P
Q 312583 258742 211199 169622 133679 103037 77366 56333 39606 26855
F16/2051 NH3 30
P 28,51 30,15 30,82 30,65 29,74 28,23 26,22 23,84 21,21 18,44
Q 289379 237031 191161 151438 117531 89106 65833
40 38,89 39,44 38,97 37,60 35,45 32,63 29,27
P
Q 265781 215832 172542 135580
50
P 50,85 49,71 47,50 44,34
F2 NH3
95 105
DV
B1
SV
B/L
A1
ca.330
H/D1
300
K
195
123
F/G 1
114 77 15 4xØ9
2
ca.265 134
152
3
4
Shaft end
8xM6 Ø82
6xM5 Ø49
A4x6,5 DIN 6888
M8x22
1.5
Ø101 h8
Ø60
Ø25
Ø21,69
1:4
25
30
32,5
59
F3 NH3
120
118 B 75
DV
L B1
A
A1
ca.390
SV
ca.365
C/E
230
D/D1/H
135 X
K 17 4xØ9
F/G
130 96.5 175
ca.345 200
Shaft end
8xM8 Ø110
6xM5 Ø49
A4x6,5 DIN 6888
M8x22
1.3
Ø130 h8
Ø60
Ø25
Ø21,69
1:4
25
30
37
63
F4 NH3
ca.305
ca.240 L B1 DV
B
SV
A
ca.425
A1
398
D
ca.200 H C/E
X D1 K
170
F
1
130 169
25 4x 11 G 2
210
213 3
ca.450 240
4
Shaft end
8xM10 130
6xM8 72
40
90
1:5
50
54
100
F5 NH3
246
B B1 DV
SV
ca.485
H
A
464
D1 C/E
347
A1
K
X D
170
25 F
G
4xØ11 240
150 169 270
ca.470 ca.355
Shaft end
8xM10 Ø150
6xM8 Ø72
A5x9 DIN 6888
M12x30
2
Ø170 h8
Ø90
Ø40
1:5
50
53
100
ca.560
D1 E
498
482
D C
X K
Y Y 1
230
G
20 F 2
290 121.5 4xØ13.5 ÖV1
342 290 3
ca.530 320
4
Shaft end
12xM10 210
8xM8 111
A5x9 DIN 6888
M12x26
2
130 h8
50
1:5
50
53,5
94
ca.305
363 170 ca.515
SV A1
B1
DV
L B2 B
B
H
ca.585 D1
E
A C
520
D 502 K
ca.295
250
Y Y
X G
F
290 143,5 4x 13,5 ÖV1
20
342 290
ca.580 320
Shaft end
12xM10 210
8xM8 111
A10x16 DIN 6888
M12x26
3,2
130 h8
60
1:5
50
57,5
115
D
Connection oil pressure
- Ø 10 mm Ø 6 mm Ø 6 mm Ø 6 mm Ø 6 mm
1
safety switch LP 1)
D1
Connection oil return from
Ø 10 mm Ø 10 mm Ø 10 mm Ø 10 mm Ø 10 mm Ø 10 mm
2
oil separator 1)
E
Connection
-
3
Ø 6 mm Ø 6 mm Ø 6 mm Ø 6 mm Ø 6 mm
oil pressure gauge 1)
Connection thermal
L 1
/8 " NPTF 1
/8 " NPTF /8 " NPTF
1 1
/8 " NPTF 1
/8 " NPTF /8 " NPTF
1
protection thermostat
ÖV1 Oil service valve 1) - - - - Ø 6 mm Ø 6 mm
1)
Compression joint for steel pipes
2)
Second sightglass can be attached, Positioning view Y (optional, only as original equipment)
View X,Y
Position view X:
F2 NH3, F3 NH3, F4 NH3, F5 NH3, F14 NH3, F16 NH3
4 hole oil sightglass
4 x M6, 10 mm deep
Position view Y:
F14 NH3, F16 NH3
Second oil sightglass can be attached as an option
(available as original equipment only)
Scope of supply F2 NH3 F3 NH3 F4 NH3 F5 NH3 F14 NH3 F16 NH3
Open type compressor for NH3 with
suction and discharge shutt-off valves
Sight glass
Shaft seal with piece of tube Elevated base plate Oil service valve
1 2 3
3 Compressor flywheel
1)
4 Shaft coupling for direct drive
Oil pressure safety switch Sight glass Thermal protection thermostat Water-cooled cylinder covers
5 7 8 9
At a glance 52
Dimensions and connections 54
Scope of supply and accessories 53
° Bock open type compressors FDK
At a glance
Based on the F compressor series with its many designs and application options, a
selection of compressor units with compact construction is available for use with
direct drive.
Force transmission is by an elastic shaft coupling. B3 drive motors can be used as
drives (optional).
Service-friendly
- Elastic shaft coupling, divided several times
- Possible to change the coupling or floating ring seal without
changing the position of the compressor or drive motor
Type key
FDK 4
40,5
FDK 4 NH3
FDK 5
73,7
FDK 5 NH3
FDK 14
101,5 / 118,9
FDK 14 NH3
FDK 16
152,2 / 178,4
FDK 16 NH3
Limits of application
You will find the operating limits diagrams for the various refrigerants in the chapter entitled „F series single-stage compressors“
from page 13 onwards as well as in „F compressors for NH3 series“ from page 37 onwards.
Performance data
You will find the performance data for the various refrigerants in the chapter entitled „F series single-stage compressors“ from
page 14 onwards as well as in „F compressors for NH3 series“ from page 38 onwards.
1
Technical data
2
You will find the technical data for the various compressors in the chapter entitled „F series single-stage compressors“ from page 22 onwards 3
as well as in „F compressors for NH3 series“ from page 40 onwards.
4
Scope of supply
You will find further information on the scope of supply for the individual basic compressors in the chapter entitled
„F series single-stage compressors“ from page 32 onwards as well as in „F compressors for NH3 series“ from page 48 onwards.
Accessories
You will find the accessories for the various compressors in the chapter entitled „F series single-stage compressors“
from page 33 onwards as well as in „F compressors for NH3 series“ from page 49 onwards.
FDK3
DV SV
ca.480
4xØ11 135
80 320
30 674 30 350
794
FDK4
DV SV
ca.530
170
100
4xØ11 210
25 875 25 240
925
FDK5
DV SV
ca.585
170
120
1
4xØ11 400 2
40 985 40 450
1155
3
4
DV SV ca.645
180
120
4xø11
50 1100 40 465
1265 505
DV SV
ca.670 (715)
213 (238)
263*
4xø11 (6xø11)
120 (140)
50 (120) 1100 (1120) 40 (60) 465 (550)
1290 (1400) 505 (600)
1
2
3
4
Many years ago, GEA Bock intensified its commitment in the area
Overview of training events offered:
of customer training.
And so we offer a comprehensive array of attractive training - GEA Bock Practitioners' Workshop
events, from two-day practitioners' workshops in Frickenhausen to - Training tailored to your individual needs
afterwork workshops throughout Germany. Regardless of the type - Training for your entire staff
of training you are interested in. - Training on your premises
Products
Sales network
News
-- Company news
-- Product news
-- Current dates
Know-How
Contact
The goal of quality leadership in all product areas has always been at
the centre of our company philosophy in our over 75-year history.