c33d5 Ds93 CPGK Revc
c33d5 Ds93 CPGK Revc
c33d5 Ds93 CPGK Revc
Frequency: 50
Fuel Type: Diesel
Standby Prime
Fuel consumption kVA (kW) kVA (kW)
3-Phase Ratings 33 (26.4) 30 (24)
1-Phase Ratings 28.3 (28.3) 25.7 (25.7)
Load 1/4 1/2 3/4 Full 1/4 1/2 3/4 Full
gph 0.7 1.0 1.4 2.0 0.5 0.8 1.2 1.6
L/hr 3 5 6 9 2 4 5 7
Fuel flow
Maximum fuel flow, L/hr 40
Maximum fuel inlet restriction, mm Hg 73
Maximum fuel inlet temperature (°C) 60
Air
3
Combustion air, m /min 1.90 1.90
Maximum air cleaner restriction, kPa 2.5
©2007 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and
Cummins are registered trademarks of Cummins Inc. PowerCommand and “Our energy working for you.” are trademarks of Cummins Power
Generation. Other company, product, or service names may be trademarks or service marks of others.
Exhaust Standby rating Prime rating
3
Exhaust gas flow at set rated load, m /min 2.3 2.3
°
Exhaust gas temperature, C 600 550
Maximum exhaust back pressure, kPa 4.75
Genset outline
Open set
Enclosed set
Outlines are for illustrative purposes only. Please refer to the genset outline drawing for an exact representation of this model.
©2007 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and
Cummins are registered trademarks of Cummins Inc. PowerCommand and “Our energy working for you.” are trademarks of Cummins Power
Generation. Other company, product, or service names may be trademarks or service marks of others.
Alternator data
1 2
Feature code Connection Temp rise degrees C Duty Alternator Voltage
TBC Wye, 3 Phase 163/125 S/P PI144G 380-440V
Ratings definitions
Emergency Standby Power (ESP) Limited-Time running Power Prime Power (PRP): Base Load (Continuous) Power
Applicable for supplying power to Applicable for supplying power to a Applicable for supplying power to Applicable for supplying power
varying electrical load for the constant electrical load for limited varying electrical load for unlimited continuously to a constant electrical
duration of power interruption of a hours. Limited Time Running hours. Prime Power (PRP) is in load for unlimited hours.
reliable utility source. Emergency Power (LTP) is in accordance with accordance with ISO 8528. Ten Continuous Power (COP) in
Standby Power (ESP) is in ISO 8528. percent overload capability is accordance with ISO 8528, ISO
accordance with ISO 8528. Fuel available in accordance with ISO 3046, AS 2789, DIN 6271 and BS
Stop power in accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514.
3046, AS 2789, DIN 6271 and BS 5514.
5514.
©2007 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and
Cummins are registered trademarks of Cummins Inc. PowerCommand and “Our energy working for you.” are trademarks of Cummins Power
Generation. Other company, product, or service names may be trademarks or service marks of others.