Model: C33 D5 (X Series)

Frequency: 50
Fuel Type: Diesel

» Generator set data sheet

Our energy working for you.™

Spec sheet: SS19-CPGK


Noise data sheet (Open/enclosed): ND50-OS550 / ND50-CS550
Airflow data sheet: AF50-550
Derate data sheet (Open/enclosed): DD50-OS550 / DD50-CS550
Transient data sheet: TD50-550

Standby Prime
Fuel consumption kVA (kW) kVA (kW)
3-Phase Ratings 33 (26.4) 30 (24)
1-Phase Ratings 28.3 (28.3) 25.7 (25.7)
Load 1/4 1/2 3/4 Full 1/4 1/2 3/4 Full
gph 0.7 1.0 1.4 2.0 0.5 0.8 1.2 1.6
L/hr 3 5 6 9 2 4 5 7

Engine Standby rating Prime rating


Engine manufacturer Cummins
Engine model X 3.3 G1
Configuration 4 Cycle; In-line; 4 Cylinder Diesel
Aspiration Naturally Aspirated
Gross engine power output, kWm 36 32
BMEP at set rated load, kPa 804 757
Bore, mm 91.4
Stroke, mm 127
Rated speed, rpm 1500
Piston speed, m/s 6.35
Compression ratio 18.5:1
Lube oil capacity, L 6.5
Overspeed limit, rpm 1725 ±25
Regenerative power, kW 2.4
Governor type Mechanical
Starting voltage 12 Volts DC

Fuel flow
Maximum fuel flow, L/hr 40
Maximum fuel inlet restriction, mm Hg 73
Maximum fuel inlet temperature (°C) 60

Air
3
Combustion air, m /min 1.90 1.90
Maximum air cleaner restriction, kPa 2.5

©2007 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and
Cummins are registered trademarks of Cummins Inc. PowerCommand and “Our energy working for you.” are trademarks of Cummins Power
Generation. Other company, product, or service names may be trademarks or service marks of others.
Exhaust Standby rating Prime rating
3
Exhaust gas flow at set rated load, m /min 2.3 2.3
°
Exhaust gas temperature, C 600 550
Maximum exhaust back pressure, kPa 4.75

Standard set-mounted radiator cooling


Ambient design, °C 50
Fan load, KWm 0.9
Coolant capacity (with radiator), L 9.6
Cooling system air flow, m3/sec @ 12.7mmH2O 106
Total heat rejection, BTU/min 1653 1539
Maximum cooling air flow static restriction mmH2O 0.3

Open set derating factors kVA (kW)


Note: Standard open genset options running at 400V, 150m above sea level. For enclosed product derates, please refer to datasheet - DD50-
CS550.

27°C 40°C 45°C 50°C 55°C


Standby 33 (26.4) 33 (26.4) 31.5 (25.2) 29.9 (23.9) 29 (23.2)
Prime 30 (24) 30 (24) 29.1 (23.3) 28.3 (22.6) 27.3 (21.8)

Weights* Open Enclosed


Unit dry weight kgs 710 1070
Unit wet weight kgs 875 1235
* Weights represent a set with standard features. See outline drawing for weights of other configurations

Dimensions Length Width Height


Standard open set dimensions 1753 930 1250
Enclosed set standard dimensions 2242 967 1513

Genset outline
Open set

Enclosed set

Outlines are for illustrative purposes only. Please refer to the genset outline drawing for an exact representation of this model.

©2007 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and
Cummins are registered trademarks of Cummins Inc. PowerCommand and “Our energy working for you.” are trademarks of Cummins Power
Generation. Other company, product, or service names may be trademarks or service marks of others.
Alternator data
1 2
Feature code Connection Temp rise degrees C Duty Alternator Voltage
TBC Wye, 3 Phase 163/125 S/P PI144G 380-440V

Ratings definitions
Emergency Standby Power (ESP) Limited-Time running Power Prime Power (PRP): Base Load (Continuous) Power
Applicable for supplying power to Applicable for supplying power to a Applicable for supplying power to Applicable for supplying power
varying electrical load for the constant electrical load for limited varying electrical load for unlimited continuously to a constant electrical
duration of power interruption of a hours. Limited Time Running hours. Prime Power (PRP) is in load for unlimited hours.
reliable utility source. Emergency Power (LTP) is in accordance with accordance with ISO 8528. Ten Continuous Power (COP) in
Standby Power (ESP) is in ISO 8528. percent overload capability is accordance with ISO 8528, ISO
accordance with ISO 8528. Fuel available in accordance with ISO 3046, AS 2789, DIN 6271 and BS
Stop power in accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514.
3046, AS 2789, DIN 6271 and BS 5514.
5514.

Formulas for calculating full load currents:

Three phase output Single phase output

kWx1000 kWxSingleP haseFactor x1000


Voltagex1. 73x0.8 Voltage

See your distributor for more information.

Cummins Power Generation


Manston Park, Columbus Avenue
Manston, Ramsgate
Kent CT12 5BF, UK
Telephone: +44 (0) 1843 255000
Fax: +44 (0) 1843 255902
E-Mail: [email protected]
Web: www.cumminspower.com

©2007 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and
Cummins are registered trademarks of Cummins Inc. PowerCommand and “Our energy working for you.” are trademarks of Cummins Power
Generation. Other company, product, or service names may be trademarks or service marks of others.

You might also like