Microwave Motion Sensor

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Microwave Motion Sensor KMY 24

Description
The KMY 24 is a microwave rader motion sensor
based on the Doppler effect. It transmits a low
energy microwave radiation at 2.45 GHz which is
reflected by objects. If the object is moving relative
to the sensor, a Doppler shift occurs. The shifted
wave is mixed with the original wave in two mixers,
resulting in two output voltage signals. The phase
shift between these two signals is negative or
positive depending on whether the target is
approaching or receding from the detector.

Features
• High sensitivity
• Dual Mixers enabling direction detecting
• High reliability
• Low power consumption
• Low harmonic emission
• Small size
• Light weight
• Low cost

Typ Marking Ordering Code Operating Frequency License No.


KMY 24 KMY 24 Q62702-R323 2.45 GHz BZT G127520H

Pin Configuration
1 − VS (GND)
2 VD1 (output voltage D1) SIEMENS
3 VD2 (output voltage D2) KMY 24
4 + VS
Notes:
1. Solder pads must not be perforated, as this will damage, 1 2 3 4 EHA07260
and may destroy the multilayer PC Board.
2. Regulations on the use of High frequency devices.
The use of high frequency devices is regulated in most
countries and certain frequencies can be subject to restrictions. The use of the KMY 24 should be clarified with
the respective authorities in each country to ensure compliance with the prevalent legislation.

Data Sheet 1 1999-04-01


KMY 24

Absolute Maximum Ratings


Parameter Symbol Limit Values Unit
Operating temperature range Top − 20 … + 60 °C
Storage temperature range Tstg − 30 … + 80 °C
Supply voltage VS 15.6 V

Electrical Characteristics
at TA = 25 °C
Parameter Symbol Limit Values Unit
min. typ. max.
Supply voltage VS 10.8 12 15.6 V
Operating frequency fo 2.40 2.45 2.48 GHz
Operating current Iop − 23 − mA
Detecting range1) rop − 5…8 − m
Amplitude of signal 1 VD1 − 1)
− mV
Quotient of amplitude of 1 and 2 VD1/VD2 − 2 −
Phase difference ϕ 2 − ϕ1 − 40 … 120 − Degrees
Equivalent isotropic radiated power at fo EIRP − 8 − dBm

1) The amplitude of the signal depends on the object size and its distance from the detector. Measurements taken
with 5 cm high, cylindrical metallic objects, moving in circles at a distance of 1 m for example, give signal
amplitudes of typically VD1 = 40 mV.

Data Sheet 2 1999-04-01


KMY 24

Output Signal
The phase difference between VD2 and VD1 is positive, if the target is receding from the
detector.
( ϕ1 – ϕ2 ) ≥ 0

EHA07261
VD1 Receding
VD2

Ch1 10 mV Ch2 10 mV M 100 ms

The phase difference between VD2 and VD1 is negative, if the target is approaching the
detector.
( ϕ1 – ϕ2 ) ≥ 0

EHA07262
Approaching VD1 VD2

Ch1 10 mV Ch2 10 mV M 100 ms

Data Sheet 3 1999-04-01


KMY 24

Typical Radiation Pattern


The diagram shows the typical radiation pattern in the x-z- and y-z-planes. The
z-direction is perpendicular to the patch antenna, x shows the longer and y the shorter
side of the rectangular antenna.

0
0 dB
30

-10 dB
60
-20 dB

90

EHA07263

Package Outline

Special Package

38 5.5
19.9

Marking
26
ø3.2
3

3 0.8 5
2.5 15.2
EHA07466

Sorts of Packing
Package outlines for tubes, trays etc. are contained in our
Data Book “Package Information”. Dimensions in mm

Data Sheet 4 1999-04-01


This datasheet has been download from:

www.datasheetcatalog.com

Datasheets for electronics components.

You might also like