Vle For Meoh/H2O System at 1 Atm Vle For Meoh/H2O System at 1 Atm
Vle For Meoh/H2O System at 1 Atm Vle For Meoh/H2O System at 1 Atm
Vle For Meoh/H2O System at 1 Atm Vle For Meoh/H2O System at 1 Atm
Temperature (oF)
210
0.9
188.42 86.9 0.108 0.44 0.408558 0.108
0.8
185.72 85.4 0.129 0.488 0.439742 0.129 200
0.6
174.38 79.1 0.268 0.648 0.595187 0.268
172.58 78.1 0.294 0.666 0.618443 0.294 180
0.5
169.7 76.5 0.352 0.704 0.666301 0.352
167.54 75.3 0.402 0.734 0.703963 0.402 170 0.4
165.56 74.2 0.454 0.76 0.740321 0.454 0.3
160
163.76 73.2 0.502 0.785 0.771772 0.502
161.6 72 0.563 0.812 0.809295 0.563 0.2
150
159.62 70.9 0.624 0.835 0.844504 0.624
0.1
156.56 69.2 0.717 0.877 0.894496 0.717
140
154.58 68.1 0.79 0.91 0.931129 0.79 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
0
152.96 67.2 0.843 0.93 0.956498 0.843 MeOH Content (mole fraction) 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
152.42 66.9 0.857 0.939 0.963042 0.857 x (mole frac MeOH)
150.26 65.7 0.938 0.971 0.999729 0.938
149 65 1 1 1.026572 1 y_calc = 1.026572 * x^0.4139722
This is a curve fit via Polymath.
(Curve above is simple connect the dots)
Experimental data from the compilation by Gmehling, J. and Onken, U. 1977. Vapor-Liquid Equilibrium Data Collection, Dechema, Frankfurt, Germany, vol. 1, p. 60.