Dekguard S TDS
Dekguard S TDS
Dekguard S TDS
Properties
The values obtained are for the Dekguard S system applied at the minimum recommended application rate.
Application Instructions Dekguard Primer should be applied in one or more coats until
the recommended application rate of 0.4 litre per square metre
Preparation has been achieved. This is best accomplished by using portable
All surfaces should be dry and free from contamination such spray equipment of the knapsack-type. Very porous surfaces
as oil, grease, loose particles, decayed matter, moss, algal may require the application of Nitoprime DG as an alternative
growth, laitance, and all traces of mould release oils and curing primer, or may require other special treatment.
compounds. This is best achieved by lightly grit-blasting the Nitoprime DG should be applied at the same coverage rate as
surface. Where moss, algae or similar growths have occurred, Dekguard Primer in continuous, multiple coats as necessary.
treatment with a proprietary biocide should be carried out after If in doubt about the condition of the substrate, contact your
the grit-blasting process. local Parchem sales office.
Note: When Nitoprime 330 has been used to cure Renderoc The primer should be allowed to dry for a minimum of two hours
repairs, it is not necessary to remove the Nitoprime 330 prior (at 20°C) before application of Dekguard S. Under no
to the application of Dekguard S. Any other curing membrane circumstances should the primer be overcoated until the surface
will need to be mechanically removed. is properly dry.
Where application over existing sound coatings is required, Dekguard S may be applied by the use of suitable brushes,
trials should be conducted to ensure compatibility and retention rollers or spray. For further information about application
of the bond between the underlying coating and the substrate. techniques, please consult your local Parchem sales office.
For further advice consult your local Parchem sales office.
All primed substrates should be treated with two coats of
It is essential to produce an unbroken coating of Dekguard S. Dekguard S. The material should be stirred thoroughly before
To ensure this is achieved, surfaces containing blow-holes or use. The first coat should be applied to all areas by the use of
similar areas of pitting should first be filled using Renderoc FC, suitable brushes, rollers or spray to achieve a uniform coating
a cementitious fairing coat (for further details, refer to separate with a wet film thickness not less than 175 microns. This coat
Technical Data Sheet). Renderoc FC should be allowed to cure should be allowed to dry before continuing.
for approximately 48 hours dependent on ambient conditions
before the application of Dekguard S. The second coat of Dekguard S should be applied exactly as
detailed above, again achieving a wet film thickness not less
than 175 microns.
Application
In order to obtain the protective properties of the Dekguard S Cleaning
system, it is important that the correct rates of application and Dekguard Primer, Nitoprime DG and Dekguard S should be
overcoating times are observed. removed from tools and equipment using Solvent 10.
Dekguard Primer Dekguard S
Limitations
Number of coats: Flood coat 2
The Dekguard S system is formulated for application to clean,
Theoretical 2.5 m²/litre 6 m²/litre
sound concrete or masonry. Where application over existing
application rate per
0.4 litres/m² 0.167 litres/m² sound coatings or paints is required, trials should be conducted
coat:
to ensure compatibility and retention of the bond between the
Theoretical wet film N/A 175 microns underlying coating and the substrate. When applied over existing
thickness per coat: coatings or paints, the performance characteristics of Dekguard
Overcoating time - S may be impaired and its fire rating invalidated. Compatibility
and soundness should be assessed on a trial area. For further
@ 2°C: 4 hours 12 hours
advice consult your local Parchem sales office.
@ 20°C: 2 hours 6 hours
Application should not commence if the temperature of the
@ 30°C: 90 minutes 5 hours substrate is below 2°C.
Application should not commence if the temperature of the Dekguard coatings are not designed nor suitable for use on
substrate is below 2°C. trafficable surfaces.
Any areas of glass should be masked. Plants, grass, joint
sealants, asphalt and bitumen-painted areas should be protected
during application.
Estimating
Supply
Coverage
Storage
Shelf life
Dekguard products have a shelf life of 12 months from date of
manufacture if kept in a dry store in the original, unopened
containers. Refer to the Use by Date indicated on the packaging.
Storage conditions
Store in cool, dry conditions, away from sources of heat and
naked flames, in the original, unopened packs. If stored at high
temperatures and/or high humidity conditions the shelf life may
be reduced.
Important notice
A Safety Data Sheet (SDS) and Technical Data Sheet (TDS) are available from the Parchem website or upon request from the nearest Parchem sales office. Read the SDS and TDS carefully
prior to use as application or performance data may change from time to time. In emergency, contact any Poisons Information Centre (phone 13 11 26 within Australia) or a doctor for advice.
Product disclaimer
This Technical Data Sheet (TDS) summarises our best knowledge of the product, including how to use and apply the product based on the information available at the time. You should read this
TDS carefully and consider the information in the context of how the product will be used, including in conjunction with any other product and the type of surfaces to, and the manner in which, the
product will be applied. Our responsibility for products sold is subject to our standard terms and conditions of sale. Parchem does not accept any liability either directly or indirectly for any losses
suffered in connection with the use or application of the product whether or not in accordance with any advice, specification, recommendation or information given by it.
*Manufactured and sold under license from Fosroc Parchem Construction Supplies Pty Ltd
International Limited. Fosroc, Dekguard and the Fosroc 7 Lucca Road, Wyong NSW 2259
logo are trade marks of Fosroc International Limited, used Phone: 1300 737 787
under license. www.parchem.com.au
ABN 80 069 961 968
constructive solutions Page 3
Distributed in New Zealand by: Concrete Plus Ltd
23 Watts Rd, Sockburn 8042 Ph: 0800 657 156