Technical Data Sheet

Approved 502;503 1,5 502 epoxy ^(ValidationDate) 1

Jotafloor Topcoat

Product description
This is a two component amide cured epoxy coating. It is a high performance product. It is easy to apply. This
product is tintable in a wide range of colours in Jotun's Multicolor Industry (MCI) system. It has excellent gloss
and colour retention. It has good chemical, abrasion and impact resistance. If enhanced slip resistance is
required Jotafloor Non Slip can be used in the system. To be used as topcoat in atmospheric environments.
Suitable on approved primers on concrete substrates.

Typical use
Designed for a wide range of floors and walls with various levels of mechanical and chemical exposure. Specially
designed for floors where a dust free, hard wearing and aesthetically pleasing coating is required. Specially
designed for industrial floors, laboratories, hospitals, food and beverage plants, kitchens, high tech
manufacturing facilities, dairies, warehouses, factories and hangars.
Other

Approvals and certificates


Determination of Bond strength to host concrete - BS 1881 : Part 207
Determination of Crack Bridgeability - ASTM C884
Determination of Rapid Chloride Permeability - AASHTO T277
Determination of Water Permeability - DIN 1048
Determination of Acid or Alkali Reaction - ASTM D543
Determination of Weather or Salt Spray Test - N.F.C. Standard
Determination of Impact Resistance - ISO 6272
Determination of Shore 'A' hardness - ASTM D2240
Determination of Taber Abrasion (1,000 Cycles) - ASTM D4060
Determination of Toxicity - BS 6920
Determination of Flame Spread - ASTM D1360
Additional certificates and approvals may be available on request.

Colours
selected range of colours tinted over Multicolor Industry tinting system (MCI)

Product data
Property Test/Standard Description
Solids by volume ISO 3233 50 ± 2 %
Gloss level (GU 60 °) ISO 2813 gloss (70-85)
Flash point ISO 3679 Method 1 25 °C
VOC-US/Hong Kong US EPA method 24 (tested) 368 g/l

The provided data is typical for factory produced products, subject to slight variation depending on colour.
All data is valid for mixed paint.
Gloss description: According to Jotun Performance Coatings' definition.

Date of issue: 4 January 2017 Page: 1/5

This Technical Data Sheet supersedes those previously issued.


The Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the
Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at www.jotun.com
Technical Data Sheet
Jotafloor Topcoat

Film thickness per coat


Typical recommended specification range

Dry film thickness 40 - 60 μm


Wet film thickness 80 - 120 μm
Theoretical spreading rate 12,5 - 8,3 m²/l

The actual spreading rate per coat may vary depending on the size of the Jotafloor Non Slip Aggregates used.

Surface preparation
To secure lasting adhesion to the subsequent product all surfaces shall be clean, dry and free from any
contamination.

Surface preparation summary table

Surface preparation

Substrate Minimum Recommended

Concrete and Coated Clean, dry and undamaged compatible Clean, dry and undamaged compatible
surfaces coating (ISO 12944-4 6.1) coating (ISO 12944-4 6.1)

Application
Application methods
The product can be applied by

Spray: Use airless spray.


Brush: Recommended for stripe coating and small areas. Care must be taken to achieve the
specified dry film thickness.
Roller: May be used. Care must be taken to achieve the specified dry film thickness.

Conditions during application :

The temperature of the substrate should be minimum 10 °C and at least 3 °C above the dew point of the air,
measured in the vicinity of the substrate. Good ventilation is usually required in confined areas to ensure proper
drying. The moisture content in the substrate should not exceed 4 % (by weight). The coating should not be
exposed to oil, chemicals or mechanical stress until fully cured.

Product mixing ratio (by volume)

Jotafloor Topcoat Comp A 4 part(s)


Jotafloor Topcoat Comp B 1 part(s)

No part mixing of this product.


Use a slow speed drill and mixing paddle. Pour the full contents of the mixed material onto the floor immediately
after mixing is completed.
The temperature of base and curing agent is recommended to be 18 °C or higher when the paint is mixed.

Date of issue: 4 January 2017 Page: 2/5

This Technical Data Sheet supersedes those previously issued.


The Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the
Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at www.jotun.com
Technical Data Sheet
Jotafloor Topcoat

Thinner/Cleaning solvent
Thinner: Jotun Thinner No. 17

Guiding data for airless spray


Nozzle tip (inch/1000): 17-23
Pressure at nozzle (minimum): 150 bar/2100 psi

Drying and Curing time


Substrate temperature 10 °C 23 °C 40 °C

Surface (touch) dry 2.5 h 1.5 h 30 min


Walk-on-dry 14 h 6.5 h 3h
Dry to over coat, minimum 14 h 7h 3h
Dried/cured for service 14 d 7d 3d

Surface (touch) dry: The state of drying when slight pressure with a finger does not leave an imprint or reveal
tackiness.

Walk-on-dry: Minimum time before the coating can tolerate normal foot traffic without permanent marks,
imprints or other physical damage.

Dry to over coat, minimum: The shortest time allowed before the next coat can be applied.

Dried/cured for service: Minimum time before the coating can be permanently exposed to the intended
environment/medium.

Induction time and Pot life


Paint temperature 23 °C

Induction time 30 min


Pot life 8h

Product compatibility
Depending on the actual exposure of the coating system, various primers and topcoats can be used in
combination with this product. Some examples are shown below. Contact Jotun for specific system
recommendation.

Previous coat: Jotafloor Sealer or Jotafloor SF Primer or Jotafloor Solvent Free Primer

Packaging (typical)
Volume Size of containers

Date of issue: 4 January 2017 Page: 3/5

This Technical Data Sheet supersedes those previously issued.


The Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the
Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at www.jotun.com
Technical Data Sheet
Jotafloor Topcoat

(litres) (litres)

Jotafloor Topcoat Comp A 4/16 5/20


Jotafloor Topcoat Comp B 1/4 1/5

The volume stated is for factory made colours. Note that local variants in pack size and filled volumes can vary
due to local regulations.

Storage
The product must be stored in accordance with national regulations. Keep the containers in a dry, cool, well
ventilated space and away from sources of heat and ignition. Containers must be kept tightly closed. Handle
with care.

Shelf life at 23 °C
Jotafloor Topcoat Comp A 24 month(s)
Jotafloor Topcoat Comp B 48 month(s)

In some markets commercial shelf life can be dictated shorter by local legislation. The above is minimum shelf
life, thereafter the paint quality is subject to re-inspection.

Caution
This product is for professional use only. The applicators and operators shall be trained, experienced and have
the capability and equipment to mix/stir and apply the coatings correctly and according to Jotun's technical
documentation. Applicators and operators shall use appropriate personal protection equipment when using this
product. This guideline is given based on the current knowledge of the product. Any suggested deviation to suit
the site conditions shall be forwarded to the responsible Jotun representative for approval before commencing
the work.

Health and safety


Please observe the precautionary notices displayed on the container. Use under well ventilated conditions. Do
not inhale spray mist. Avoid skin contact. Spillage on the skin should immediately be removed with suitable
cleanser, soap and water. Eyes should be well flushed with water and medical attention sought immediately.

Colour variation
When applicable, products primarily meant for use as primers or antifoulings may have slight colour variations
from batch to batch. Such products may fade and chalk when exposed to sunlight and weathering.

Disclaimer
The information in this document is given to the best of Jotun's knowledge, based on laboratory testing and
practical experience. Jotun's products are considered as semi-finished goods and as such, products are often
used under conditions beyond Jotun's control. Jotun cannot guarantee anything but the quality of the product
itself. Minor product variations may be implemented in order to comply with local requirements. Jotun reserves
the right to change the given data without further notice.

Users should always consult Jotun for specific guidance on the general suitability of this product for their needs
and specific application practices.

If there is any inconsistency between different language issues of this document, the English (United Kingdom)

Date of issue: 4 January 2017 Page: 4/5

This Technical Data Sheet supersedes those previously issued.


The Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the
Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at www.jotun.com
Technical Data Sheet
Jotafloor Topcoat

version will prevail.

Date of issue: 4 January 2017 Page: 5/5

This Technical Data Sheet supersedes those previously issued.


The Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the
Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at www.jotun.com

You might also like