Add Info B-82974EN 01
Add Info B-82974EN 01
Add Info B-82974EN 01
2. Summary of Change
New,Add,
Applicable
Group Name/Outline Correct,
Date
Delete
Basic
Setting up TCP/IP Add ASAP
Function
Optional
Function
Unit
Maintenanc
e Parts
Correction
Other
TITLE
FANUC Robot series R-30iA / R-30iA Mate Ethernet Function
SHEET
EDIT. DATE DESIG. DESCRIPTION FANUC LTD 1/2
Add the following description at the end of 2.4 Setting up TCP/IP
Caution for setting IP address
Each IP address for 2 Ethernet ports of R-30iA must be in network with different subnet.
Different subnet means network address which determined by subnet mask is different.
For example, network address is 192.168.1 and host address is 10 when subnet mask is
255.255.255.0 and IP address is 192.168.1.10.
"Host-179 IP Address mis-configuration" alarm will be asserted when IP address for 2 Ethernet ports
has the same subnet.
2 Ethernet ports of R-30iA are not able to use as Hub.
R-30iA is not able to set 2 nodes for one network.
External PLC
Ethernet/IP Scanner
TITLE
FANUC Robot series R-30iA / R-30iA Mate Ethernet Function
SHEET
EDIT. DATE DESIG. DESCRIPTION FANUC LTD 2/2