Survey Meter Reading Primer - : Bartlett Nuclear, Inc. - May 2007 1
Survey Meter Reading Primer - : Bartlett Nuclear, Inc. - May 2007 1
Survey Meter Reading Primer - : Bartlett Nuclear, Inc. - May 2007 1
Reading Primer
3,200 cpm
SCALE = x10
Needle is on the 320 marking (320 x10 = 3200)
10,000 cpm
SCALE = 100x
Needle is on the 100 marking (100 x 100 = 10,000 cpm)
22,000 cpm
SCALE = 100x
Needle is on the 220 marking (220 x 100 = 22,000 cpm)
300 cpm
SCALE = 0.1x
Needle is on the 3K (3000) marking (3000 x 0.1 = 300 cpm)
20,000 cpm
SCALE = 10x
Needle is on the 2K (2000) marking (2000 x 10 = 20,000 cpm)
400 mR/h
3.6 mR/hr
2500 mR/hr
8.5 R/hr
SCALE = 50 R/hr
The 1 represents 10 R/h. The needle is between the 8
R/hr and 9 R/hr markings
502 counts
48 mR/hr
SCALE = x100
Needle is on the 0.48 marking (0.48 x100 = 48)
7.3 mR/hr
SCALE = x10
Needle is on the 0.73 marking clearly between the 0.72
and 0.74 markings
(0.73 x10 = 7.3)
30.6 mR/h
35.7 R/h
1.0 mR/h
300 mR/h
1.169 R/h
89.7 mR/h
SCALE = 5 R/h
The 1 represents 1 R/h. The needle is between the 0.8
R/hr and 1 R/hr markings
SCALE = 50 mR/h
The 3 represents 30 mR/h and the 4 represents 40
mR/h. The needle is on the 36 marking.