Ed Us 041502
Ed Us 041502
Ed Us 041502
Split Type
Air Conditioners
FTK(X)-N Series
FTK09NMVJU RK09NMVJU
FTK12NMVJU RK12NMVJU
Cooling Only
FTK18NMVJU RK18NMVJU
FTK24NMVJU RK24NMVJU
FTX09NMVJU RX09NMVJU
FTX12NMVJU RX12NMVJU
Heat Pump
FTX18NMVJU RX18NMVJU
FTX24NMVJU RX24NMVJU
1. Power Supply
Indoor Unit Outdoor Unit Power Supply
FTK09NMVJU RK09NMVJU
FTK12NMVJU RK12NMVJU
FTK18NMVJU RK18NMVJU
FTK24NMVJU RK24NMVJU
1 phase, 208 - 230 V, 60 Hz
FTX09NMVJU RX09NMVJU
FTX12NMVJU RX12NMVJU
FTX18NMVJU RX18NMVJU
FTX24NMVJU RX24NMVJU
2. Functions
FTK09/12NMVJU
FTX09/12NMVJU
FTK09/12NMVJU
FTX09/12NMVJU
RK09/12NMVJU
RX09/12NMVJU
RK09/12NMVJU
RX09/12NMVJU
Category Functions Category Functions
Basic Inverter (with inverter power control) z z Health & Air-purifying filter
Function 10 ~ 10 ~ Clean Photocatalytic deodorizing filter
Operation limit for cooling (CDB)
46 46 Air-purifying filter with photocatalytic
Operation limit for cooling (FDB) 50 ~ 50 ~ deodorizing function
114.8 114.8
Titanium apatite photocatalytic z z
15 ~ air-purifying filter (option)
Operation limit for heating (CWB)
18 Air filter (prefilter) z z
5~ Wipe-clean flat panel z z
Operation limit for heating (FWB)
64.4 Washable grille
PAM control z z MOLD PROOF operation
Standby electricity saving z z Good-sleep cooling operation
Compressor Oval scroll compressor Timer WEEKLY TIMER
Swing compressor z z Count up-down ON/OFF timer z z
Rotary compressor 24-hour ON/OFF TIMER
Reluctance DC motor z z NIGHT SET mode z z
Comfortable Power-airflow flap (horizontal blade) z z Worry Free Auto-restart (after power failure) z z
Airflow Power-airflow dual flaps (Reliability & Self-diagnosis (R/C, LED) z z
Durability)
Power-airflow diffuser Wiring error check function
Wide-angle louvers (vertical blade) z z Anti-corrosion treatment of outdoor heat z z
Auto-swing (up and down) z z exchanger
Auto-swing (right and left) Flexibility Multi-split / split type compatible indoor
3-D airflow unit
COMFORT AIRFLOW operation z z H/P, C/O compatible indoor unit
Comfort Auto fan speed z z Flexible power supply correspondence
Control Indoor unit quiet operation z z
Chargeless 32.8 ft 32.8 ft
NIGHT QUIET mode (automatic) (10 m) (10 m)
OUTDOOR UNIT QUIET operation Either side drain (right or left) z z
(manual) Power selection
INTELLIGENT EYE operation Low temperature cooling operation z z
Quick warming function z (15C) (5F)
Hot-start function z F/C changeover R/C temperature z z
Automatic defrosting z display (factory setting: F)
Operation Automatic operation z Remote 5-rooms centralized controller (option) z z
Program dry function z z
Control
Remote control adaptor z z
Fan only z z (normal open-pulse contact) (option)
Lifestyle New POWERFUL operation Remote control adaptor
Convenience (non-inverter) z z
(normal open contact) (option)
Inverter POWERFUL operation z z DIII-NET compatible (adaptor) (option) z z
Priority-room setting Remote Wireless z z
COOL / HEAT mode lock Controller Wired (option) z z
HOME LEAVE operation
ECONO operation z z
Indoor unit ON/OFF button z z
Signal receiving sign z z
R/C with back light z z
Temperature display
Note: z : Available
: Not available
FTK18/24NMVJU
FTX18/24NMVJU
FTK18/24NMVJU
FTX18/24NMVJU
RK18/24NMVJU
RX18/24NMVJU
RK18/24NMVJU
RX18/24NMVJU
Category Functions Category Functions
Basic Inverter (with inverter power control) z z Health & Air-purifying filter
Function 10 ~ 10 ~ Clean Photocatalytic deodorizing filter
Operation limit for cooling (CDB)
46 46 Air-purifying filter with photocatalytic
Operation limit for cooling (FDB) 50 ~ 50 ~ deodorizing function
114.8 114.8
Titanium apatite photocatalytic z z
15 ~ air-purifying filter (option)
Operation limit for heating (CWB)
18 Air filter (prefilter) z z
5~ Wipe-clean flat panel z z
Operation limit for heating (FWB)
64.4 Washable grille
PAM control z z MOLD PROOF operation
Standby electricity saving z z Good-sleep cooling operation
Compressor Oval scroll compressor Timer WEEKLY TIMER
Swing compressor z z Count up-down ON/OFF timer z z
Rotary compressor 24-hour ON/OFF TIMER
Reluctance DC motor z z NIGHT SET mode z z
Comfortable Power-airflow flap (horizontal blade) Worry Free Auto-restart (after power failure) z z
Airflow Power-airflow dual flaps z z
(Reliability & Self-diagnosis (R/C, LED) z z
Durability)
Power-airflow diffuser Wiring error check function
Wide-angle louvers (vertical blade) z z Anti-corrosion treatment of outdoor heat z z
Auto-swing (up and down) z z exchanger
Auto-swing (right and left) Flexibility Multi-split / split type compatible indoor
3-D airflow unit
COMFORT AIRFLOW operation z z H/P, C/O compatible indoor unit
Comfort Auto fan speed z z Flexible power supply correspondence
Control
Indoor unit quiet operation z z 32.8 ft 32.8 ft
Chargeless (10 m) (10 m)
NIGHT QUIET mode (automatic)
OUTDOOR UNIT QUIET operation Either side drain (right or left) z z
(manual)
Power selection
INTELLIGENT EYE operation Low temperature cooling operation
(15C) (5F) z z
Quick warming function z
Hot-start function z F/C changeover R/C temperature
display (factory setting: F) z z
Automatic defrosting z
Operation Automatic operation z Remote 5-rooms centralized controller (option) z z
Control
Program dry function z z Remote control adaptor
(normal open-pulse contact) (option) z z
Fan only z z
Lifestyle New POWERFUL operation Remote control adaptor z z
Convenience (non-inverter) (normal open contact) (option)
Inverter POWERFUL operation z z DIII-NET compatible (adaptor) (option) z z
Priority-room setting Remote Wireless z z
COOL / HEAT mode lock Controller Wired (option) z z
HOME LEAVE operation
ECONO operation z z
Indoor unit ON/OFF button z z
Signal receiving sign z z
R/C with back light z z
Temperature display
Note: z : Available
: Not available
3. Specifications
3.1 Cooling Only
60 Hz, 208 - 230 V
Indoor Unit FTK09NMVJU FTK12NMVJU
Model
Outdoor Unit RK09NMVJU RK12NMVJU
kW 2.64 (1.30 ~ 3.00) 3.20 (1.30 ~ 3.90)
Capacity Btu/h 9,000 (4,400 ~ 10,200) 10,900 (4,400 ~ 13,300)
Rated (Min. ~ Max.)
kcal/h 2,270 (1,120 ~ 2,580) 2,750 (1,120 ~ 3,350)
Moisture Removal gal/h 0.32 0.45
Running Current (Rated) A 3.77 - 3.41 4.42 - 3.99
Power Consumption W 721 (250 ~ 962) 874 (260 ~ 1,383)
Rated (Min. ~ Max.)
Power Factor (Rated) % 91.9 - 91.9 95.1 - 95.2
COP Rated (Min. ~ Max.) W/W 3.66 (5.20 ~ 3.12) 3.66 (5.00 ~ 2.82)
EER Rated (Min. ~ Max.) Btu/hW 12.5 (17.6 ~ 10.6) 12.5 (16.9 ~ 9.6)
SEER 19.0 19.0
Liquid in. (mm) 1/4 ( 6.4) 1/4 ( 6.4)
Piping Connections Gas in. (mm) 3/8 ( 9.5) 3/8 ( 9.5)
Drain in. (mm) 5/8 ( 16.0) 5/8 ( 16.0)
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Max. Interunit Piping Length ft (m) 65-5/8 (20) 65-5/8 (20)
Max. Interunit Height Difference ft (m) 49-1/4 (15) 49-1/4 (15)
Chargeless ft (m) 32-13/16 (10) 32-13/16 (10)
Amount of Additional Charge of oz/ft 0.21 (20) 0.21 (20)
Refrigerant (g/m)
Indoor Unit FTK09NMVJU FTK12NMVJU
Front Panel Color White White
H 11.8 (417) 12.3 (434)
M m/min 8.4 (297) 8.8 (311)
Airflow Rate (cfm)
L 6.9 (244) 7.0 (247)
SL 4.0 (141) 4.1 (145)
Type Cross Flow Fan Cross Flow Fan
Fan Motor Output W 21 28
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downward Right, Left, Horizontal, Downward
Air Filter Removable, Washable, Mildew Proof Removable, Washable, Mildew Proof
Running Current (Rated) A 0.25 - 0.23 0.28 - 0.25
Power Consumption (Rated) W 28 - 28 31 - 31
Power Factor (Rated) % 53.8 - 52.9 53.2 - 53.9
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H W D) in. (mm) 11-1/4 30-5/16 8-3/4 (285 770 223) 11-1/4 30-5/16 8-3/4 (285 770 223)
Packaged Dimensions (H W D) in. (mm) 12 32-11/16 14-3/16 (305 831 360) 12 32-11/16 14-3/16 (305 831 360)
Weight Lbs (kg) 18 (8) 18 (8)
Gross Weight Lbs (kg) 24 (11) 25 (11)
Sound Pressure Level H / M / L / SL dB(A) 43 / 36 / 30 / 19 45 / 37 / 30 / 19
Outdoor Unit RK09NMVJU RK12NMVJU
Casing Color Ivory White Ivory White
Type Hermetically Sealed Swing Type Hermetically Sealed Swing Type
Compressor Model 1YC23AUXD 1YC23AUXD
Motor Output W 790 790
Type FVC50K FVC50K
Refrigerant Oil
Charge oz (L) 12.4 (0.375) 12.4 (0.375)
Type R-410A R-410A
Refrigerant
Charge Lbs (kg) 1.54 (0.70) 2.09 (0.95)
H m/min 31.2 (1,102) 31.3 (1,105)
Airflow Rate (cfm)
SL 29.3 (1,035) 24.5 (865)
Type Propeller Propeller
Fan
Motor Output W 14 18
Running Current (Rated) A 3.52 - 3.18 4.14 - 3.74
Power Consumption (Rated) W 693 - 693 843 - 843
Power Factor (Rated) % 94.7 - 94.7 97.9 - 98.0
Starting Current A 3.77
Dimensions (H W D) in. (mm) 21-5/8 26-9/16 11-3/16 (550 675 284) 21-5/8 26-9/16 11-3/16 (550 675 284)
Packaged Dimensions (H W D) in. (mm) 24-3/4 32-11/16 16 (629 830 407) 24-3/4 32-11/16 16 (629 830 407)
Weight Lbs (kg) 55 (25) 60 (27)
Gross Weight Lbs (kg) 66 (30) 71 (32)
Sound Pressure Level H dB(A) 46 49
Drawing No. C: 3D093560 C: 3D093561A
Note: The data are based on the conditions shown in the table below.
Indoor ; 80FDB (26.7CDB) / 67FWB (19.4CWB) Conversion Formulae
Cooling
Outdoor ; 95FDB (35CDB) / 75FWB (24CWB) kcal/h = kW 860
Piping Length 25 ft (7.5 m) Btu/h = kW 3412
cfm = m/min 35.3
Note: The data are based on the conditions shown in the table below.
Indoor ; 80FDB (26.7CDB) / 67FWB (19.4CWB) Conversion Formulae
Cooling
Outdoor ; 95FDB (35CDB) / 75FWB (24CWB) kcal/h = kW 860
Piping Length 25 ft (7.5 m) Btu/h = kW 3412
cfm = m/min 35.3
Note: The data are based on the conditions shown in the table below.
Indoor ; 80FDB (26.7CDB) / 67FWB (19.4CWB) Conversion Formulae
Cooling
Outdoor ; 95FDB (35CDB) / 75FWB (24CWB) kcal/h = kW 860
Indoor ; 70FDB (21CDB) / 60FWB (15.6CWB) Btu/h = kW 3412
Heating cfm = m/min 35.3
Outdoor ; 47FDB (8.3CDB) / 43FWB (6CWB)
Piping Length 25 ft (7.5 m)
Note: The data are based on the conditions shown in the table below.
Indoor ; 80FDB (26.7CDB) / 67FWB (19.4CWB) Conversion Formulae
Cooling
Outdoor ; 95FDB (35CDB) / 75FWB (24CWB) kcal/h = kW 860
Indoor ; 70FDB (21CDB) / 60FWB (15.6CWB) Btu/h = kW 3412
Heating cfm = m/min 35.3
Outdoor ; 47FDB (8.3CDB) / 43FWB (6CWB)
Piping Length 25 ft (7.5 m)
4. Dimensions
4.1 Indoor Unit
4.1.1 Cooling Only
FTK09/12NMVJU
INCLUDING
THE MARK () SHOWS PIPING DIRECTION REQUIRED SPACE AIR FLOW (INDOOR)
MOUNTING PLATE
REAR 30-5/16 (770 mm) 8-7/8 (225 mm)
PERFORMANCE)
8-3/4 (223 mm)
TERMINAL BLOCK
FRONT PANEL FIXING SCREWS 1-15/16 (50 mm) MIN 1-15/16 (50 mm) MIN
WITH EARTH
(INSIDE) (SPACE FOR (SPACE FOR
TERMINAL
BOTTOM
FLAPS
ABOUT 13 (330 mm)
SIGNAL RECEIVER GAS PIPE 3/8 (9.5 mm) CuT
(THE LENGTH OF PIPE OUTSIDE DRAIN HOSE ABOUT 14-9/16 (370 mm)
OPERATION LAMP
THE UNIT: ABOUT 14-3/16 (360 mm)) (CONNECTING PART
TIMER LAMP ABOUT 15-3/8 (390 mm)
I.D. 9/16 (14 mm)
INDOOR UNIT ON/OFF SWITCH O.D. 5/8 (16 mm)
ROOM TEMP. THERMISTOR LIQUID PIPE 1/4 (6.4 mm) CuT
(THE HOSE LENGTH OF OUTSIDE
(INSIDE) (THE LENGTH OF PIPE OUTSIDE
THE UNIT IS ABOUT 18-1/2 (470 mm))
THE UNIT: ABOUT 16-1/8 (410 mm))
MODEL NAME
PLATE
5 5 45
45
50 50
FAN
1-3/4 (44.5 mm)
FTK18NMVJU
THE MARK () SHOWS PIPING DIRECTION AIR FLOW (INDOOR)
REAR 39 (990mm)
PERFORMANCE)
(SPACE FOR
1-3/16 (30mm) MIN
LEFT RIGHT
(INCLUDING
MOUNTING PLATE )
10-7/16 (265mm)
10-3/8 (263mm) 1-15/16 (50mm) MIN
1-15/16 (50mm) MIN
(SPACE FOR REQUIRED SPACE
11-5/8 (295mm)
9/16 (14.6mm)
7-1/16 (180mm)
15 10
30
25
55 70 80
65
RIGHT/LEFT (MANUAL) WALL HOLE FOR EMBEDDED PIPING 2-3/8 (60mm) WALL HOLE
1-7/8 (48mm)
3-1/8 (80mm) HOLE 3-1/8 (80mm) HOLE
STANDARD LOCATIONS OF WALL HOLES
WIRELESS REMOTE CONTROLLER 45 45
3D091781
(ARC480A9)
FTK24NMVJU
PERFORMANCE)
1-3/16 (30mm) MIN
LEFT RIGHT
(SPACE FOR
( INCLUDING
MOUNTING PLATE )
10-7/16 (265mm)
10-3/8 (263mm) 1-15/16 (50mm) MIN
(SPACE FOR 1-15/16 (50mm) MIN
REQUIRED SPACE
11-5/8 (295mm)
GENERAL RATING MAINTENANCE) (SPACE FOR
NAME PLATE MAINTENANCE)
TERMINAL BLOCK
WITH EARTH
TERMINAL
(INSIDE)
BOTTOM
1/2 (12mm)
FRONT GRILLE FIXING SCREWS UP AND DOWN WIND DIRECTION
(INSIDE) CONTROL BLADE MOVABLE RANGE
ABOUT 15-3/4 (400mm) DRAIN HOSE
FLAPS
GAS PIPE 5/8 (15.9mm) CuT GAS PIPE
ABOUT 17-5/16 (440mm)
LIQUID PIPE
SIGNAL RECEIVER ABOUT 18-1/8 (460mm)
OPERATION LAMP
TIMER LAMP
INDOOR UNIT ON/OFF SWITCH DRAIN HOSE
LIQUID PIPE 1/4 (6.4mm) CuT
(CONNECTING PART
ROOM TEMP. THERMISTOR ABOUT 14-3/16 (360mm)
I.D. 9/16 (14mm)
(INSIDE)
MODEL NAME PLATE O.D. 5/8 (16mm) ABOUT 14-3/8 (365mm)
ABOUT 17-3/4 (450mm)
5/16 (7.9mm)
SIGNAL TRANSMITTER BLADE ANGLES
1-7/8 (48mm) 13/16 (20mm) 39 (990mm)
UP/DOWN (AUTOMATIC) 29-3/8 (746mm) 5 (126.5mm)
COOLING, DRY FAN
1-3/4 (44.5mm)
11-5/8 (295mm)
1-3/4 (44.5mm)
9/16 (14.6mm)
7-1/16 (180mm)
15 10
30
25
55 70 80
65
FTX09/12NMVJU
INCLUDING
THE MARK () SHOWS PIPING DIRECTION REQUIRED SPACE AIR FLOW (INDOOR)
MOUNTING PLATE
REAR 30-5/16 (770 mm) 8-7/8 (225 mm)
PERFORMANCE)
8-3/4 (223 mm)
TERMINAL BLOCK
FRONT PANEL FIXING SCREWS 1-15/16 (50 mm) MIN 1-15/16 (50 mm) MIN
WITH EARTH
(INSIDE) (SPACE FOR (SPACE FOR
TERMINAL
1-1/16 (27 mm)
BOTTOM
FLAPS
GAS PIPE 3/8 (9.5 mm) CuT ABOUT 13 (330 mm)
SIGNAL RECEIVER DRAIN HOSE
(THE LENGTH OF PIPE OUTSIDE ABOUT 14-9/16 (370 mm)
OPERATION LAMP (CONNECTING PART
THE UNIT: ABOUT 14-3/16 (360 mm))
TIMER LAMP I.D. 9/16 (14 mm) ABOUT 15-3/8 (390 mm)
INDOOR UNIT ON/OFF SWITCH O.D. 5/8 (16 mm)
LIQUID PIPE 1/4 (6.4 mm) CuT
ROOM TEMP. THERMISTOR (THE HOSE LENGTH OF OUTSIDE
(THE LENGTH OF PIPE OUTSIDE
(INSIDE) THE UNIT IS ABOUT 18-1/2 (470 mm))
THE UNIT: ABOUT 16-1/8 (410 mm))
MODEL NAME
PLATE
9/16 (14.6 mm)
SIGNAL TRANSMITTER
1-7/8 (48 mm) 13/16 (20 mm) BLADE ANGLE 30-5/16 (770 mm)
UP/DOWN (AUTOMATIC) RIGHT/LEFT 21-1/8 (536.6 mm) 4-9/16 (116.5 mm)
(MANUAL)
1-3/4 (44.5 mm)
COOLING DRY
11-1/4 (285 mm)
7-1/16 (180 mm)
5 5 45
45
50 50
HEATING FAN
1-3/4 (44.5 mm)
FTX18NMVJU
THE MARK () SHOWS PIPING DIRECTION
AIR FLOW (INDOOR)
REAR 39 (990mm)
PERFORMANCE)
1-3/16 (30mm) MIN
LEFT RIGHT
(SPACE FOR
(INCLUDING
MOUNTING PLATE )
10-7/16 (265mm)
10-3/8 (263mm) 1-15/16 (50mm) MIN
1-15/16 (50mm) MIN
(SPACE FOR REQUIRED SPACE
TERMINAL BLOCK
WITH EARTH
TERMINAL
BOTTOM (INSIDE)
FRONT GRILLE FIXING SCREWS UP AND DOWN WIND DIRECTION
(INSIDE) CONTROL BLADE MOVABLE RANGE ABOUT 15-3/4 (400mm) DRAIN HOSE
FLAPS
GAS PIPE
GAS PIPE 1/2 (12.7mm) CuT ABOUT 17-5/16 (440mm) LIQUID PIPE
SIGNAL RECEIVER ABOUT 18-1/8 (460mm)
OPERATION LAMP
TIMER LAMP
INDOOR UNIT ON/OFF SWITCH DRAIN HOSE LIQUID PIPE 1/4 (6.4mm) CuT
ROOM TEMP. THERMISTOR (CONNECTING PART ABOUT 14-3/16 (360mm)
(INSIDE) I.D. 9/16 (14mm)
MODEL NAME PLATE O.D. 5/8 (16mm) ABOUT 14-3/8 (365mm)
ABOUT 17-3/4 (450mm)
5/16 (7.9mm)
SIGNAL TRANSMITTER
BLADE ANGLES
1-7/8 (48mm) 13/16 (20mm) 39 (990mm)
UP/DOWN (AUTOMATIC) 29-3/8 (746mm) 5 (126.5mm)
COOLING, DRY HEATING FAN
1-3/4 (44.5mm)
11-5/8 (295mm)
1-3/4 (44.5mm)
9/16 (14.6mm)
7-1/16 (180mm)
15 10
20
30
35 25
55 70 80 80
65 65
FTX24NMVJU
PERFORMANCE)
1-3/16 (30mm) MIN
(SPACE FOR
LEFT RIGHT
(INCLUDING
MOUNTING PLATE )
10-7/16 (265mm)
10-3/8 (263mm) 1-15/16 (50mm) MIN
(SPACE FOR 1-15/16 (50mm) MIN
REQUIRED SPACE
1/2 (12mm) 11-5/8 (295mm)
9/16 (14.6mm)
7-1/16 (180mm)
15 10
15 20
30
35 25
55 70 80 80
65 65
RIGHT/LEFT (MANUAL) 1-7/8 (48mm) WALL HOLE FOR EMBEDDED PIPING 2-3/8 (60mm) WALL HOLE
3-1/8 (80mm) HOLE 3-1/8 (80mm) HOLE
STANDARD LOCATIONS OF WALL HOLES
WIRELESS REMOTE CONTROLLER 45 45
3D091780
(ARC480A8)
RK09/12NMVJU, RX09/12NMVJU
18-1/2 (470) 3-13/16 (97)
1-1/8 (29)
1/2 (13)
16-1/16 (408)
12-13/16 (326)
12-1/8 (308)
1/2 (13)
DRAIN OUTLET
(I.D.5/8 (15.9mm) HOSE FOR CONNECTION
WITH DRAIN JOINT)
6-7/16 (164)
21-5/8 (550)
4-1/8 (104)
SERVICE
PORT
6-1/4 (159)
13/16 (20)
IN CASE OF REMOVING
5-7/8 (150)
STOP VALVE COVER AND
WALL HEIGHT ON AIR OUTLET SIDE TERMINAL STRIP COVER
MINIMUM SPACE FOR AIR PASSAGE
=LESS THAN 47-1/4 (1200)
3-15/16 (100)
1-15/16 (50)
3-15/16 (100)
5-7/8 (150)
1-15/16 (50)
UNIT: inch (mm)
C: 3D092206
RK18NMVJU, RX18NMVJU
HANDLE 9/16 (14) 34-1/4 (870) 2-3/4 (70)
1/4 (7) 12-5/8 (320) 1-3/16 (30) ELECTRIC WIRE INTAKE OUTDOOR AIR THERMISTOR
BRAND NAME PLATE
MANUFACTURER'S LABEL
28-15/16 (735)
3/4 (19)
7/8 (23)
4-HOLES FOR FOUNDATION BOLTS 9/16 (14.5)
(M8 OR M10) 23-5/8 (600) 4-15/16 (125)
13-5/8 (346) 7/16 (11)
(INSTALLATION LEG
PITCH)
11-7/16 (291)
14-1/2 (368)
3-15/16 (100)
LIQUID
STOP VALVE 20-11/16 (525)
(1/4 (6.4) CuT)
DRAIN OUTLET
GAS (I.D.5/8 (15.9) HOSE FOR
STOP VALVE
3-15/16 (100)
13-3/4 (350)
13-3/4 (350)
4-1/8 (105)
6-1/2 (165)
SERVICE
PORT
RK24NMVJU, RX24NMVJU
HANDLE 9/16 (14) 34-1/4 (870) 2-3/4 (70)
1/4 (7) 12-5/8 (320) 1-3/16 (30) ELECTRIC WIRE INTAKE OUTDOOR AIR THERMISTOR
BRAND NAME PLATE
MANUFACTURER'S LABEL
28-15/16 (735)
3/4 (19)
7/8 (23)
4-HOLES FOR FOUNDATION BOLTS 9/16 (14.5)
(M8 OR M10) 23-5/8 (600) 4-15/16 (125)
13-5/8 (346) 7/16 (11)
(INSTALLATION LEG
PITCH)
11-7/16 (291)
14-1/2 (368)
3-15/16 (100)
WALL HEIGHT ON AIR OUTLET SIDE
GROUND TERMINAL MINIMUM SPACE FOR AIR PASSAGE =LESS THAN 47-1/4 (1200)
LIQUID
STOP VALVE 20-11/16 (525)
(1/4 (6.4) CuT)
DRAIN OUTLET
GAS (I.D. 5/8 (15.9) HOSE FOR
STOP VALVE
3-15/16 (100)
13-3/4 (350)
CONNECTION WITH DRAIN JOINT)
(5/8 (15.9) CuT)
3-15/16 (100)
13-3/4 (350)
4-1/8 (105)
6-1/2 (165)
13-3/4 (350)
SERVICE
PORT
5. Wiring Diagrams
5.1 Indoor Unit
FTK09/12NMVJU, FTX09/12NMVJU
PCB2 PCB1
S27 S26 MR10 FIELD WIRING.
10 BLK 10
LED1 H1P BLK
BLK
TRANSMISSION
CIRCUIT GRN/YLW
LED2 H2P BLK MR10
BLK 3
BLK
FG
GRN
BLK 2
S1W BLK H3 OUTDOOR
BLK
V2 RED 3
1
R1T
1 BLK 1 ~ ~ H2
WHT 2
RECTIFIER
t
- + H1
BLK 1
FU1 3.15A
X1M
SIGNAL
RECEIVER - + CAUTION
IPM200 NOTE THAT OPERATION WILL RESTART
AUTOMATICALLY IF THE MAIN POWER
SUPPLY IS TURNED OFF AND THEN BACK
1 2 1 5 1 12 1 S403 10 ON AGAIN.
S32 S6 S200
WIRELESS
YLW
ORG
PNK
BLK
BLK
ORG
WHT
RED
REMOTE
RED
YLW
BLU
BLK
BLU
CONTROLLER
t
R2T
M M INDOOR
M1S M1F
FG : FRAME GROUND M1S : SWING MOTOR S1W : OPERATION SWITCH : PROTECTIVE GROUND
FU1 : FUSE PCB1, PCB2 : PRINTED CIRCUIT BOARD X1M : TERMINAL STRIP
H1~H3 : HARNESS R1T, R2T : THERMISTOR V2 : VARISTOR
M1F : FAN MOTOR S6~S403 : CONNECTOR MR10 : RELAY
C: 3D086429B
FTK18/24NMVJU, FTX18/24NMVJU
WHT
WHT
WHT
BLK
ORG
WHT
RED
BLU
BLK
BLK
BLK
BLK
RK09/12NMVJU, RX09/12NMVJU
Z1C IPM1
X1M N=2 FU3
HL1 20A MRM10 HR1 L1R HR2 DB1
1 L1 1 BLK BRN ORG ~
2 L2 2 WHT ZF
HN1 V2
INDOOR
3 3 RED ~ C400
S V3
GRN/YLW
L1 C405
L2 MR30 FU1 V150
SA1 3.15A W V U
Z2C FU2
N=2 E1 3.15A
POWER SUPPLY
MRCW
PS
E2
GRN
1 5 1 2 1 6 1 3 1 7
OUTDOOR S80 S71 S30
PCB1
Z3C
WHT
ORG
RED
RED
WHT
ORG
BRN
RED
BLK
BLK
BLK
BLK
BLK
BLK
RED
YLW
BLU
BLU
BLK
BLK
N=2
RED
YLW
BLU
NOTE
Y1S V
1. REFER TO THE NAME PLATE FOR THE POWER
M t t t MS W MS U
IN CASE OF
REQUIREMENTS. Q1L
HEAT PUMP TYPE 3 ~
C400, C405 : CAPACITOR R1T R3T
Y1E M1F
(OUTDOOR) R2T (DISCHARGE) M1C
DB1 : DIODE BRIDGE (CONDENSER)
FU1, FU2, FU3 : FUSE
IPM1 : INTELLIGENT POWER MODULE PS : SWITCHING POWER SUPPLY X1M : TERMINAL STRIP
L1, L2 : LIVE Q1L : OVERLOAD PROTECTOR Y1E : ELECTRONIC EXPANSION VALVE COIL
L1R : REACTOR R1T, R2T, R3T : THERMISTOR Y1S : REVERSING SOLENOID VALVE COIL
M1C : COMPRESSOR MOTOR S20, S30, S40, Z1C~Z3C : FERRITE CORE
M1F : FAN MOTOR S71, S80, S90 : CONNECTOR ZF : NOISE FILTER
MR30, MRM10, MRCW : MAGNETIC RELAY SA1 : SURGE ARRESTER : PROTECTIVE GROUND
PCB1 : PRINTED CIRCUIT BOARD V2, V3, V150 : VARISTOR
C: 3D089069
RK18/24NMVJU, RX18/24NMVJU
FIELD WIRING
INDOOR
N=5 MRM20
FU3 IPM1
TO INDOOR UNIT X1M Z3C DB1
HL1 30A
1 L1 1 BLK ~ + +
HN1 MRM10
2 L2 2 WHT V2 ZF +
S PAM
3 3 RED ~ - - C7
V3 FU1 V1 -
3.15A
GRN/YLW
L1 FU2
L2 MR30 3.15A W V U
N=4 SA1
Z2C PS Z1C
E1 N=4
POWER SUPPLY MRCW
RED
YLW
BLU
E2
GRN
PCB
OUTDOOR
WHT
WHT
ORG
ORG
RED
RED
RED
BRN
RED
YLW
BLU
BLU
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
NOTE
1.REFER TO THE NAMEPLATE FOR THE POWER REQUIREMENTS. V
W U
C7 : CAPACITOR t t t MS MS
Y1S Q1L
DB1 : DIODE BRIDGE
M
R1T R3T 3~
IN CASE OF (OUTDOOR) R2T (DISCHARGE)
FU1, FU2, FU3 : FUSE HEAT PUMP TYPE Y1E M1F M1C
(CONDENSER)
IPM1 : INTELLIGENT POWER MODULE
L1, L2 : LIVE
M1C : COMPRESSOR MOTOR PS : SWITCHING POWER SUPPLY V1, V2, V3 : VARISTOR : PROTECTIVE GROUND
M1F : FAN MOTOR Q1L : OVERLOAD PROTECTOR X1M : TERMINAL BLOCK : GROUND
MRM10, MRM20, R1T, R2T, R3T : THERMISTOR Y1E : ELECTRONIC EXPANSION VALVE COIL
MR30, MRCW : MAGNETIC RELAY S20, S40, S70, Y1S : REVERSING SOLENOID VALVE COIL
PAM : PULSE AMPLITUDE MODULATION S80, S90, X11A : CONNECTOR Z1C, Z2C, Z3C : FERRITE CORE
PCB : PRINTED CIRCUIT BOARD SA1 : SURGE ABSORBER ZF : NOISE FILTER C: 3D089070
6. Piping Diagrams
6.1 Indoor Unit
6.1.1 Cooling Only
FTK09/12NMVJU FTK18NMVJU
HEAT EXCHANGER
1/4 CuT
DISTRIBUTOR
HEAT EXCHANGER
1/4 CuT
THERMISTOR
ON HEAT EXCH.
THERMISTOR
CROSS FLOW FAN ON HEAT EXCH.
FIELD PIPING CROSS FLOW FAN FIELD PIPING
(1/4 CuT) SINGLE UNION 1/4 CuT M
JOINT M FAN MOTOR
HEADER
FIELD PIPING FAN MOTOR
(3/8 CuT) SINGLE UNION 3/8 CuT
FIELD PIPING
JOINT
1/2 CuT 1/2 CuT
4D092108 4D091771
FTK24NMVJU
INDOOR UNIT
1/4 CuT
DISTRIBUTOR
HEAT EXCHANGER
THERMISTOR
CROSS FLOW FAN ON HEAT EXCH.
FIELD PIPING
1/4 CuT M
FAN MOTOR
HEADER
FIELD PIPING
5/8 CuT 1/2 CuT
REFRIGERANT FLOW
COOLING
4D091770
FTX09/12NMVJU FTX18NMVJU
HEAT EXCHANGER
1/4 CuT
DISTRIBUTOR
HEAT EXCHANGER
THERMISTOR
1/4 CuT
ON HEAT EXCH.
THERMISTOR
CROSS FLOW FAN ON HEAT EXCH.
FIELD PIPING
FIELD PIPING CROSS FLOW FAN
(1/4 CuT) SINGLE UNION
1/4 CuT M
JOINT M FAN MOTOR
FAN MOTOR HEADER
FIELD PIPING
(3/8 CuT) SINGLE UNION 3/8 CuT
FIELD PIPING
JOINT
1/2 CuT 1/2 CuT
4D091708A 4D091769
FTX24NMVJU
INDOOR UNIT
1/4 CuT
DISTRIBUTOR
HEAT EXCHANGER
THERMISTOR
CROSS FLOW FAN ON HEAT EXCH.
FIELD PIPING
1/4 CuT M
FAN MOTOR
HEADER
FIELD PIPING
5/8 CuT 1/2 CuT
REFRIGERANT FLOW
COOLING
HEATING
4D091768
RK09NMVJU
OUTDOOR UNIT
OUTDOOR TEMPERATURE
9/32 CuT HEAT EXCHANGER THERMISTOR
9/32 CuT
HEAT EXCHANGER
THERMISTOR
WITH
3/8 CuT FILTER
3/16 CuT
FOUR WAY
VALVE FIELD PIPING
(1/4 CuT)
5/16 CuT
3/8 CuT
LIQUID STOP
DISCHARGE PIPE VALVE
THERMISTOR
MUFFLER
3/8 CuT 3/8 CuT FIELD PIPING
5/16 CuT REFRIGERANT FLOW
ACCUMULATOR (3/8 CuT)
MUFFLER GAS STOP VALVE COOLING
WITH SERVICE PORT
COMPRESSOR
3D092245
RK12NMVJU
OUTDOOR UNIT
OUTDOOR TEMPERATURE
9/32 CuT HEAT EXCHANGER THERMISTOR
3/8 CuT
9/32 CuT
HEAT EXCHANGER
THERMISTOR
3/16 CuT
1/4 CuT 1/4 CuT
3/16 CuT
M MUFFLER
WITH MOTOR
FILTER OPERATED
PROPELLER FAN VALVE MUFFLER
3/8 CuT
WITH
3/8 CuT FILTER
3/16 CuT
FOUR WAY
VALVE
FIELD PIPING
3/8 CuT
5/16 CuT
MUFFLER
3/8 CuT 3/8 CuT FIELD PIPING
5/16 CuT REFRIGERANT FLOW
ACCUMULATOR (3/8 CuT)
MUFFLER GAS STOP VALVE COOLING
WITH SERVICE PORT
COMPRESSOR
3D092208
RK18NMVJU
OUTDOOR UNIT
HEAT EXCHANGER OUTDOOR AIR
9/32 CuT
THERMISTOR
9/32 CuT
1/2 CuT
9/32 CuT
9/32 CuT CAPILLARY TUBE 1
5/32 CuT
CAPILLARY TUBE 2 1/4 CuT 1/4 CuT
5/32 CuT REFRIGERANT FLOW
COOLING
MUFFLER
WITH
HEAT EXCHANGER FILTER
THERMISTOR
ELECTRONIC
M EXPANSION
VALVE
PROPELLER FAN
STRAINER
1/2 CuT
1/4 CuT
1/2 CuT 1/2 CuT
FOUR WAY LIQUID
VALVE RECEIVER
5/16 CuT
DISCHARGE PIPE
THERMISTOR MUFFLER FIELD PIPING
1/4 CuT (1/4 CuT)
LIQUID
STOP VALVE
MUFFLER ACCUMULATOR
1/2 CuT FIELD PIPING
5/16 CuT
(1/2 CuT)
GAS STOP VALVE
COMPRESSOR WITH SERVICE PORT
3D092222
RK24NMVJU
OUTDOOR UNIT
HEAT EXCHANGER OUTDOOR AIR
9/32 CuT THERMISTOR
9/32 CuT
5/32 CuT
9/32 CuT
CAPILLARY TUBE 2
5/32 CuT
9/32 CuT 1/4 CuT 1/4 CuT REFRIGERANT FLOW
9/32 CuT CAPILLARY TUBE 3 COOLING
5/32 CuT
MUFFLER
WITH
HEAT EXCHANGER FILTER
THERMISTOR ELECTRONIC
M EXPANSION
VALVE
PROPELLER FAN
STRAINER
1/2 CuT
1/4 CuT
1/2 CuT 1/2 CuT
FOUR WAY LIQUID
VALVE RECEIVER
5/16 CuT
DISCHARGE PIPE
THERMISTOR MUFFLER FIELD PIPING
1/4 CuT (1/4 CuT)
LIQUID
STOP VALVE
MUFFLER
ACCUMULATOR 1/2 CuT FIELD PIPING
5/16 CuT
(5/8 CuT)
GAS STOP VALVE
COMPRESSOR WITH SERVICE PORT
3D092250
RX09NMVJU
OUTDOOR UNIT
OUTDOOR TEMPERATURE
9/32 CuT HEAT EXCHANGER THERMISTOR
9/32 CuT
HEAT EXCHANGER
THERMISTOR
WITH
3/8 CuT FILTER
3/16 CuT
FOUR WAY
VALVE FIELD PIPING
ON: HEATING
5/16 CuT
(1/4 CuT)
3/8 CuT
LIQUID STOP
DISCHARGE PIPE VALVE
THERMISTOR
MUFFLER
3/8 CuT 3/8 CuT FIELD PIPING
5/16 CuT REFRIGERANT FLOW
ACCUMULATOR (3/8 CuT)
MUFFLER GAS STOP VALVE COOLING
WITH SERVICE PORT HEATING
COMPRESSOR
3D092244
RX12NMVJU
OUTDOOR UNIT
OUTDOOR TEMPERATURE
9/32 CuT HEAT EXCHANGER THERMISTOR
3/8 CuT
9/32 CuT
HEAT EXCHANGER
THERMISTOR
3/16 CuT
1/4 CuT 1/4 CuT
3/16 CuT
M MUFFLER
WITH
MOTOR
FILTER
OPERATED
PROPELLER FAN VALVE MUFFLER
3/8 CuT
WITH
3/8 CuT FILTER
3/16 CuT
FOUR WAY
VALVE FIELD PIPING
3/8 CuT
ON: HEATING
5/16 CuT
MUFFLER
3/8 CuT 3/8 CuT FIELD PIPING
5/16 CuT REFRIGERANT FLOW
ACCUMULATOR (3/8 CuT)
MUFFLER GAS STOP VALVE COOLING
WITH SERVICE PORT HEATING
COMPRESSOR
3D092207
RX18NMVJU
OUTDOOR UNIT
HEAT EXCHANGER OUTDOOR AIR
9/32 CuT THERMISTOR
9/32 CuT
1/2 CuT
9/32 CuT
9/32 CuT CAPILLARY TUBE 1
5/32 CuT
CAPILLARY TUBE 2 1/4 CuT 1/4 CuT
5/32 CuT REFRIGERANT FLOW
COOLING
MUFFLER HEATING
WITH
HEAT EXCHANGER FILTER
THERMISTOR ELECTRONIC
M EXPANSION
VALVE
PROPELLER FAN
STRAINER
1/2 CuT
1/4 CuT
1/2 CuT 1/2 CuT
FOUR WAY LIQUID
VALVE RECEIVER
ON: HEATING
5/16 CuT
DISCHARGE PIPE
THERMISTOR MUFFLER FIELD PIPING
1/4 CuT (1/4 CuT)
LIQUID
STOP VALVE
MUFFLER
ACCUMULATOR 1/2 CuT FIELD PIPING
5/16 CuT
(1/2 CuT)
GAS STOP VALVE
COMPRESSOR WITH SERVICE PORT
3D092220
RX24NMVJU
OUTDOOR UNIT
HEAT EXCHANGER OUTDOOR AIR
9/32 CuT THERMISTOR
9/32 CuT
5/32 CuT
9/32 CuT
CAPILLARY TUBE 2
5/32 CuT
9/32 CuT 1/4 CuT 1/4 CuT REFRIGERANT FLOW
9/32 CuT CAPILLARY TUBE 3 COOLING
5/32 CuT
HEATING
MUFFLER
WITH
HEAT EXCHANGER FILTER
THERMISTOR ELECTRONIC
M EXPANSION
VALVE
PROPELLER FAN
STRAINER
1/2 CuT
1/4 CuT
1/2 CuT 1/2 CuT
FOUR WAY LIQUID
VALVE RECEIVER
ON: HEATING
5/16 CuT
DISCHARGE PIPE
THERMISTOR MUFFLER FIELD PIPING
1/4 CuT (1/4 CuT)
LIQUID
STOP VALVE
MUFFLER
ACCUMULATOR 1/2 CuT FIELD PIPING
5/16 CuT
(5/8 CuT)
GAS STOP VALVE
COMPRESSOR WITH SERVICE PORT
3D092249
7. Capacity Tables
7.1 Cooling Only
FTK09NMVJU + RK09NMVJU
AFR 11.8
BF 0.22
60 Hz, 208 V
Temp: Celsius
TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (CDB)
EWB EDB 20 25 30 32 35 40
C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20.0 2.70 2.27 0.55 2.58 2.21 0.61 2.46 2.15 0.66 2.41 2.13 0.68 2.34 2.10 0.71 2.21 2.04 0.77
16.0 22.0 2.83 2.23 0.56 2.70 2.18 0.61 2.58 2.12 0.66 2.53 2.10 0.68 2.46 2.07 0.72 2.33 2.02 0.77
18.0 25.0 2.95 2.37 0.56 2.83 2.32 0.61 2.70 2.27 0.67 2.65 2.25 0.69 2.58 2.22 0.72 2.46 2.18 0.77
19.4 26.7 3.01 2.54 0.56 2.89 2.49 0.61 2.76 2.44 0.67 2.71 2.42 0.69 2.64 2.39 0.72 2.52 2.35 0.77
22.0 30.0 3.19 2.46 0.57 3.07 2.42 0.62 2.95 2.37 0.67 2.90 2.36 0.69 2.82 2.33 0.73 2.70 2.29 0.78
24.0 32.0 3.31 2.41 0.57 3.19 2.37 0.62 3.07 2.33 0.68 3.02 2.31 0.70 2.94 2.29 0.73 2.82 2.25 0.78
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (FDB)
EWB EDB 68 77 86 90 95 104
F F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 9.23 7.73 0.55 8.81 7.54 0.61 8.39 7.34 0.66 8.22 7.27 0.68 7.97 7.15 0.71 7.55 6.96 0.77
60.8 71.6 9.64 7.61 0.56 9.22 7.42 0.61 8.80 7.24 0.66 8.64 7.17 0.68 8.39 7.06 0.72 7.97 6.89 0.77
64.4 77.0 10.06 8.09 0.56 9.64 7.92 0.61 9.22 7.76 0.67 9.05 7.69 0.69 8.80 7.59 0.72 8.38 7.43 0.77
67.0 80.0 10.27 8.65 0.56 9.85 8.49 0.61 9.43 8.33 0.67 9.26 8.26 0.69 9.00 8.17 0.72 8.59 8.01 0.77
71.6 86.0 10.89 8.39 0.57 10.47 8.24 0.62 10.05 8.10 0.67 9.88 8.05 0.69 9.63 7.96 0.73 9.21 7.82 0.78
75.2 89.6 11.30 8.21 0.57 10.88 8.08 0.62 10.46 7.95 0.68 10.30 7.90 0.70 10.05 7.82 0.73 9.63 7.69 0.78
60 Hz, 230 V
Temp: Celsius
TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (CDB)
EWB EDB 20 25 30 32 35 40
C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20.0 2.70 2.27 0.55 2.58 2.21 0.61 2.46 2.15 0.66 2.41 2.13 0.68 2.34 2.10 0.71 2.21 2.04 0.77
16.0 22.0 2.83 2.23 0.56 2.70 2.18 0.61 2.58 2.12 0.66 2.53 2.10 0.68 2.46 2.07 0.72 2.33 2.02 0.77
18.0 25.0 2.95 2.37 0.56 2.83 2.32 0.61 2.70 2.27 0.67 2.65 2.25 0.69 2.58 2.22 0.72 2.46 2.18 0.77
19.4 26.7 3.01 2.54 0.56 2.89 2.49 0.61 2.76 2.44 0.67 2.71 2.42 0.69 2.64 2.39 0.72 2.52 2.35 0.77
22.0 30.0 3.19 2.46 0.57 3.07 2.42 0.62 2.95 2.37 0.67 2.90 2.36 0.69 2.82 2.33 0.73 2.70 2.29 0.78
24.0 32.0 3.31 2.41 0.57 3.19 2.37 0.62 3.07 2.33 0.68 3.02 2.31 0.70 2.94 2.29 0.73 2.82 2.25 0.78
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (FDB)
EWB EDB 68 77 86 90 95 104
F F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 9.23 7.73 0.55 8.81 7.54 0.61 8.39 7.34 0.66 8.22 7.27 0.68 7.97 7.15 0.71 7.55 6.96 0.77
60.8 71.6 9.64 7.61 0.56 9.22 7.42 0.61 8.80 7.24 0.66 8.64 7.17 0.68 8.39 7.06 0.72 7.97 6.89 0.77
64.4 77.0 10.06 8.09 0.56 9.64 7.92 0.61 9.22 7.76 0.67 9.05 7.69 0.69 8.80 7.59 0.72 8.38 7.43 0.77
67.0 80.0 10.27 8.65 0.56 9.85 8.49 0.61 9.43 8.33 0.67 9.26 8.26 0.69 9.00 8.17 0.72 8.59 8.01 0.77
71.6 86.0 10.89 8.39 0.57 10.47 8.24 0.62 10.05 8.10 0.67 9.88 8.05 0.69 9.63 7.96 0.73 9.21 7.82 0.78
75.2 89.6 11.30 8.21 0.57 10.88 8.08 0.62 10.46 7.95 0.68 10.30 7.90 0.70 10.05 7.82 0.73 9.63 7.69 0.78
Symbols: Notes:
AFR : Airflow rate (m /min.)
3
1. shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in the
BF : Bypass factor above tables. (Figures out of the tables should not be used for calculation.)
EWB : Entering wet bulb temp. (C) / (F) 3. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 25 ft (7.5 m)
EDB : Entering dry bulb temp. (C) / (F) Level difference : 0 ft (0 m)
TC : Total capacity (kW) / (kBtu/h) 4. Cooling capacity at 15CDB and 5FDB.
SHC : Sensible heat capacity (kW) / (kBtu/h) Temp: Celsius
PI : Power input (kW) TC, SHC, PI: kW
60 Hz, 208 - 230 V
INDOOR OUTDOOR
EWB EDB 15 (CDB)
C C TC SHC PI
14.0 20.0 2.90 2.18 0.37
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
60 Hz, 208 - 230 V
INDOOR OUTDOOR
EWB EDB 5 (FDB)
F F TC SHC PI
57.2 68.0 9.90 7.45 0.37
3D093239
FTK12NMVJU + RK12NMVJU
AFR 12.3
BF 0.16
60 Hz, 208 V
Temp: Celsius
TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (CDB)
EWB EDB 20 25 30 32 35 40
C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20.0 3.28 2.66 0.67 3.13 2.59 0.74 2.98 2.52 0.80 2.92 2.49 0.83 2.83 2.45 0.86 2.68 2.38 0.93
16.0 22.0 3.43 2.61 0.67 3.28 2.55 0.74 3.13 2.48 0.80 3.07 2.46 0.83 2.98 2.42 0.87 2.83 2.35 0.93
18.0 25.0 3.57 2.77 0.68 3.42 2.71 0.74 3.28 2.65 0.81 3.22 2.63 0.83 3.13 2.59 0.87 2.98 2.53 0.94
19.4 26.7 3.65 2.95 0.68 3.50 2.89 0.74 3.35 2.84 0.81 3.29 2.81 0.84 3.20 2.78 0.87 3.05 2.72 0.94
22.0 30.0 3.87 2.86 0.69 3.72 2.81 0.75 3.57 2.76 0.82 3.51 2.74 0.84 3.42 2.70 0.88 3.27 2.65 0.94
24.0 32.0 4.02 2.79 0.69 3.87 2.75 0.75 3.72 2.70 0.82 3.66 2.68 0.84 3.57 2.65 0.88 3.42 2.61 0.95
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (FDB)
EWB EDB 68 77 86 90 95 104
F F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 11.19 9.07 0.67 10.68 8.83 0.74 10.17 8.59 0.80 9.97 8.50 0.83 9.66 8.36 0.86 9.15 8.12 0.93
60.8 71.6 11.69 8.92 0.67 11.18 8.69 0.74 10.67 8.47 0.80 10.47 8.38 0.83 10.16 8.25 0.87 9.66 8.03 0.93
64.4 77.0 12.19 9.46 0.68 11.68 9.25 0.74 11.18 9.04 0.81 10.97 8.96 0.83 10.67 8.83 0.87 10.16 8.63 0.94
67.0 80.0 12.44 10.07 0.68 11.94 9.87 0.74 11.43 9.67 0.81 11.22 9.59 0.84 10.90 9.48 0.87 10.41 9.28 0.94
71.6 86.0 13.20 9.75 0.69 12.69 9.58 0.75 12.18 9.40 0.82 11.98 9.33 0.84 11.67 9.23 0.88 11.16 9.06 0.94
75.2 89.6 13.70 9.53 0.69 13.19 9.37 0.75 12.68 9.21 0.82 12.48 9.15 0.84 12.18 9.05 0.88 11.67 8.90 0.95
60 Hz, 230 V
Temp: Celsius
TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (CDB)
EWB EDB 20 25 30 32 35 40
C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20.0 3.28 2.66 0.67 3.13 2.59 0.74 2.98 2.52 0.80 2.92 2.49 0.83 2.83 2.45 0.86 2.68 2.38 0.93
16.0 22.0 3.43 2.61 0.67 3.28 2.55 0.74 3.13 2.48 0.80 3.07 2.46 0.83 2.98 2.42 0.87 2.83 2.35 0.93
18.0 25.0 3.57 2.77 0.68 3.42 2.71 0.74 3.28 2.65 0.81 3.22 2.63 0.83 3.13 2.59 0.87 2.98 2.53 0.94
19.4 26.7 3.65 2.95 0.68 3.50 2.89 0.74 3.35 2.84 0.81 3.29 2.81 0.84 3.20 2.78 0.87 3.05 2.72 0.94
22.0 30.0 3.87 2.86 0.69 3.72 2.81 0.75 3.57 2.76 0.82 3.51 2.74 0.84 3.42 2.70 0.88 3.27 2.65 0.94
24.0 32.0 4.02 2.79 0.69 3.87 2.75 0.75 3.72 2.70 0.82 3.66 2.68 0.84 3.57 2.65 0.88 3.42 2.61 0.95
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (FDB)
EWB EDB 68 77 86 90 95 104
F F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 11.19 9.07 0.67 10.68 8.83 0.74 10.17 8.59 0.80 9.97 8.50 0.83 9.66 8.36 0.86 9.15 8.12 0.93
60.8 71.6 11.69 8.92 0.67 11.18 8.69 0.74 10.67 8.47 0.80 10.47 8.38 0.83 10.16 8.25 0.87 9.66 8.03 0.93
64.4 77.0 12.19 9.46 0.68 11.68 9.25 0.74 11.18 9.04 0.81 10.97 8.96 0.83 10.67 8.83 0.87 10.16 8.63 0.94
67.0 80.0 12.44 10.07 0.68 11.94 9.87 0.74 11.43 9.67 0.81 11.22 9.59 0.84 10.90 9.48 0.87 10.41 9.28 0.94
71.6 86.0 13.20 9.75 0.69 12.69 9.58 0.75 12.18 9.40 0.82 11.98 9.33 0.84 11.67 9.23 0.88 11.16 9.06 0.94
75.2 89.6 13.70 9.53 0.69 13.19 9.37 0.75 12.68 9.21 0.82 12.48 9.15 0.84 12.18 9.05 0.88 11.67 8.90 0.95
Symbols: Notes:
AFR : Airflow rate (m /min.)
3
1. shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in the
BF : Bypass factor above tables. (Figures out of the tables should not be used for calculation.)
EWB : Entering wet bulb temp. (C) / (F) 3. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 25 ft (7.5 m)
EDB : Entering dry bulb temp. (C) / (F) Level difference : 0 ft (0 m)
TC : Total capacity (kW) / (kBtu/h) 4. Cooling capacity at 15CDB and 5FDB.
SHC : Sensible heat capacity (kW) / (kBtu/h) Temp: Celsius
PI : Power input (kW) TC, SHC, PI: kW
60 Hz, 208 - 230 V
INDOOR OUTDOOR
EWB EDB 15 (CDB)
C C TC SHC PI
14.0 20.0 3.42 2.53 0.52
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
60 Hz, 208 - 230 V
INDOOR OUTDOOR
EWB EDB 5 (FDB)
F F TC SHC PI
57.2 68.0 11.66 8.61 0.52
3D093240
FTK18NMVJU + RK18NMVJU
AFR 20.2
BF 0.27
60 Hz, 208 V
Temp: Celsius
TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (CDB)
EWB EDB 20 25 30 32 35 40
C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20.0 5.41 4.15 1.11 5.16 4.03 1.21 4.92 3.91 1.32 4.82 3.86 1.36 4.67 3.79 1.43 4.43 3.67 1.53
16.0 22.0 5.65 4.08 1.11 5.41 3.96 1.22 5.16 3.85 1.32 5.06 3.81 1.37 4.92 3.74 1.43 4.67 3.63 1.54
18.0 25.0 5.90 4.29 1.12 5.65 4.19 1.22 5.40 4.08 1.33 5.31 4.04 1.37 5.16 3.98 1.44 4.91 3.88 1.54
19.4 26.7 6.02 4.54 1.12 5.77 4.44 1.23 5.53 4.34 1.33 5.43 4.30 1.38 5.28 4.24 1.44 5.03 4.15 1.55
22.0 30.0 6.38 4.39 1.13 6.14 4.30 1.24 5.89 4.21 1.34 5.79 4.18 1.39 5.64 4.12 1.45 5.40 4.04 1.56
24.0 32.0 6.63 4.28 1.14 6.38 4.20 1.24 6.13 4.12 1.35 6.04 4.09 1.39 5.89 4.04 1.46 5.64 3.96 1.56
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (FDB)
EWB EDB 68 77 86 90 95 104
F F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 18.46 14.15 1.11 17.62 13.74 1.21 16.78 13.34 1.32 16.44 13.17 1.36 15.94 12.93 1.43 15.10 12.54 1.53
60.8 71.6 19.29 13.91 1.11 18.45 13.52 1.22 17.61 13.14 1.32 17.27 12.99 1.37 16.77 12.77 1.43 15.93 12.40 1.54
64.4 77.0 20.12 14.64 1.12 19.28 14.28 1.22 18.44 13.93 1.33 18.10 13.79 1.37 17.60 13.58 1.44 16.76 13.23 1.54
67.0 80.0 20.53 15.50 1.12 19.69 15.16 1.23 18.85 14.82 1.33 18.52 14.68 1.38 18.00 14.48 1.44 17.18 14.15 1.55
71.6 86.0 21.78 14.97 1.13 20.94 14.67 1.24 20.10 14.37 1.34 19.76 14.25 1.39 19.26 14.07 1.45 18.42 13.78 1.56
75.2 89.6 22.61 14.60 1.14 21.77 14.32 1.24 20.93 14.05 1.35 20.59 13.94 1.39 20.09 13.78 1.46 19.25 13.51 1.56
60 Hz, 230 V
Temp: Celsius
TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (CDB)
EWB EDB 20 25 30 32 35 40
C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20.0 5.41 4.15 1.11 5.16 4.03 1.21 4.92 3.91 1.32 4.82 3.86 1.36 4.67 3.79 1.43 4.43 3.67 1.53
16.0 22.0 5.65 4.08 1.11 5.41 3.96 1.22 5.16 3.85 1.32 5.06 3.81 1.37 4.92 3.74 1.43 4.67 3.63 1.54
18.0 25.0 5.90 4.29 1.12 5.65 4.19 1.22 5.40 4.08 1.33 5.31 4.04 1.37 5.16 3.98 1.44 4.91 3.88 1.54
19.4 26.7 6.02 4.54 1.12 5.77 4.44 1.23 5.53 4.34 1.33 5.43 4.30 1.38 5.28 4.24 1.44 5.03 4.15 1.55
22.0 30.0 6.38 4.39 1.13 6.14 4.30 1.24 5.89 4.21 1.34 5.79 4.18 1.39 5.64 4.12 1.45 5.40 4.04 1.56
24.0 32.0 6.63 4.28 1.14 6.38 4.20 1.24 6.13 4.12 1.35 6.04 4.09 1.39 5.89 4.04 1.46 5.64 3.96 1.56
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (FDB)
EWB EDB 68 77 86 90 95 104
F F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 18.46 14.15 1.11 17.62 13.74 1.21 16.78 13.34 1.32 16.44 13.17 1.36 15.94 12.93 1.43 15.10 12.54 1.53
60.8 71.6 19.29 13.91 1.11 18.45 13.52 1.22 17.61 13.14 1.32 17.27 12.99 1.37 16.77 12.77 1.43 15.93 12.40 1.54
64.4 77.0 20.12 14.64 1.12 19.28 14.28 1.22 18.44 13.93 1.33 18.10 13.79 1.37 17.60 13.58 1.44 16.76 13.23 1.54
67.0 80.0 20.53 15.50 1.12 19.69 15.16 1.23 18.85 14.82 1.33 18.52 14.68 1.38 18.00 14.48 1.44 17.18 14.15 1.55
71.6 86.0 21.78 14.97 1.13 20.94 14.67 1.24 20.10 14.37 1.34 19.76 14.25 1.39 19.26 14.07 1.45 18.42 13.78 1.56
75.2 89.6 22.61 14.60 1.14 21.77 14.32 1.24 20.93 14.05 1.35 20.59 13.94 1.39 20.09 13.78 1.46 19.25 13.51 1.56
Symbols: Notes:
AFR : Airflow rate (m /min.)
3
1. shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in the
BF : Bypass factor above tables. (Figures out of the tables should not be used for calculation.)
EWB : Entering wet bulb temp. (C) / (F) 3. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 25 ft (7.5 m)
EDB : Entering dry bulb temp. (C) / (F) Level difference : 0 ft (0 m)
TC : Total capacity (kW) / (kBtu/h) 4. Cooling capacity at 15CDB and 5FDB.
SHC : Sensible heat capacity (kW) / (kBtu/h) Temp: Celsius
PI : Power input (kW) TC, SHC, PI: kW
60 Hz, 208 - 230 V
INDOOR OUTDOOR
EWB EDB 15 (CDB)
C C TC SHC PI
14.0 20.0 5.44 4.02 0.71
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
60 Hz, 208 - 230 V
INDOOR OUTDOOR
EWB EDB 5 (FDB)
F F TC SHC PI
57.2 68.0 18.54 13.69 0.71
3D093241
FTK24NMVJU + RK24NMVJU
AFR 20.2
BF 0.27
60 Hz, 208 V
Temp: Celsius
TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (CDB)
EWB EDB 20 25 30 32 35 40
C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20.0 6.05 4.47 1.29 6.05 4.47 1.43 5.77 4.33 1.55 5.66 4.27 1.60 5.49 4.19 1.68 5.20 4.04 1.71
16.0 22.0 6.64 4.54 1.31 6.35 4.40 1.43 6.06 4.27 1.56 5.94 4.21 1.61 5.77 4.13 1.68 5.48 4.00 1.72
18.0 25.0 6.92 4.74 1.32 6.63 4.61 1.44 6.35 4.49 1.57 6.23 4.43 1.62 6.06 4.36 1.69 5.77 4.24 1.73
19.4 26.7 7.07 4.99 1.32 6.78 4.86 1.45 6.49 4.74 1.57 6.37 4.69 1.62 6.20 4.62 1.70 5.91 4.50 1.73
22.0 30.0 7.49 4.80 1.33 7.21 4.69 1.46 6.92 4.59 1.58 6.80 4.54 1.63 6.63 4.48 1.71 6.34 4.37 1.74
24.0 32.0 7.78 4.67 1.34 7.49 4.57 1.46 7.20 4.47 1.59 7.09 4.43 1.64 6.91 4.38 1.71 6.63 4.28 1.75
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (FDB)
EWB EDB 68 77 86 90 95 104
F F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 20.65 15.25 1.29 20.65 15.25 1.43 19.70 14.77 1.55 19.31 14.57 1.60 18.72 14.28 1.68 17.73 13.80 1.71
60.8 71.6 22.65 15.49 1.31 21.66 15.02 1.43 20.68 14.55 1.56 20.28 14.37 1.61 19.69 14.09 1.68 18.71 13.64 1.72
64.4 77.0 23.62 16.18 1.32 22.64 15.74 1.44 21.65 15.30 1.57 21.26 15.13 1.62 20.67 14.87 1.69 19.68 14.45 1.73
67.0 80.0 24.11 17.01 1.32 23.12 16.59 1.45 22.14 16.17 1.57 21.75 16.01 1.62 21.20 15.76 1.70 20.17 15.35 1.73
71.6 86.0 25.57 16.39 1.33 24.59 16.01 1.46 23.60 15.64 1.58 23.21 15.50 1.63 22.62 15.28 1.71 21.63 14.92 1.74
75.2 89.6 26.55 15.94 1.34 25.56 15.60 1.46 24.58 15.26 1.59 24.18 15.13 1.64 23.59 14.93 1.71 22.61 14.60 1.75
60 Hz, 230 V
Temp: Celsius
TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (CDB)
EWB EDB 20 25 30 32 35 40
C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20.0 6.05 4.47 1.29 6.05 4.47 1.43 5.77 4.33 1.55 5.66 4.27 1.60 5.49 4.19 1.68 5.20 4.04 1.71
16.0 22.0 6.64 4.54 1.31 6.35 4.40 1.43 6.06 4.27 1.56 5.94 4.21 1.61 5.77 4.13 1.68 5.48 4.00 1.72
18.0 25.0 6.92 4.74 1.32 6.63 4.61 1.44 6.35 4.49 1.57 6.23 4.43 1.62 6.06 4.36 1.69 5.77 4.24 1.73
19.4 26.7 7.07 4.99 1.32 6.78 4.86 1.45 6.49 4.74 1.57 6.37 4.69 1.62 6.20 4.62 1.70 5.91 4.50 1.73
22.0 30.0 7.49 4.80 1.33 7.21 4.69 1.46 6.92 4.59 1.58 6.80 4.54 1.63 6.63 4.48 1.71 6.34 4.37 1.74
24.0 32.0 7.78 4.67 1.34 7.49 4.57 1.46 7.20 4.47 1.59 7.09 4.43 1.64 6.91 4.38 1.71 6.63 4.28 1.75
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (FDB)
EWB EDB 68 77 86 90 95 104
F F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 20.65 15.25 1.29 20.65 15.25 1.43 19.70 14.77 1.55 19.31 14.57 1.60 18.72 14.28 1.68 17.73 13.80 1.71
60.8 71.6 22.65 15.49 1.31 21.66 15.02 1.43 20.68 14.55 1.56 20.28 14.37 1.61 19.69 14.09 1.68 18.71 13.64 1.72
64.4 77.0 23.62 16.18 1.32 22.64 15.74 1.44 21.65 15.30 1.57 21.26 15.13 1.62 20.67 14.87 1.69 19.68 14.45 1.73
67.0 80.0 24.11 17.01 1.32 23.12 16.59 1.45 22.14 16.17 1.57 21.75 16.01 1.62 21.20 15.76 1.70 20.17 15.35 1.73
71.6 86.0 25.57 16.39 1.33 24.59 16.01 1.46 23.60 15.64 1.58 23.21 15.50 1.63 22.62 15.28 1.71 21.63 14.92 1.74
75.2 89.6 26.55 15.94 1.34 25.56 15.60 1.46 24.58 15.26 1.59 24.18 15.13 1.64 23.59 14.93 1.71 22.61 14.60 1.75
Symbols: Notes:
AFR : Airflow rate (m /min.)
3
1. shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in the
BF : Bypass factor above tables. (Figures out of the tables should not be used for calculation.)
EWB : Entering wet bulb temp. (C) / (F) 3. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 25 ft (7.5 m)
EDB : Entering dry bulb temp. (C) / (F) Level difference : 0 ft (0 m)
TC : Total capacity (kW) / (kBtu/h) 4. Cooling capacity at 15CDB and 5FDB.
SHC : Sensible heat capacity (kW) / (kBtu/h) Temp: Celsius
PI : Power input (kW) TC, SHC, PI: kW
60 Hz, 208 - 230 V
INDOOR OUTDOOR
EWB EDB 15 (CDB)
C C TC SHC PI
14.0 20.0 5.95 4.39 0.56
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
60 Hz, 208 - 230 V
INDOOR OUTDOOR
EWB EDB 5 (FDB)
F F TC SHC PI
57.2 68.0 20.35 15.03 0.56
3D093242
FTX09NMVJU + RX09NMVJU
60 Hz, 208 V
Cooling
AFR 11.8
BF 0.22
Temp: Celsius
TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (CDB)
EWB EDB 20 25 30 32 35 40
C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20.0 2.70 2.27 0.55 2.58 2.21 0.61 2.46 2.15 0.66 2.41 2.13 0.68 2.34 2.10 0.71 2.21 2.04 0.77
16.0 22.0 2.83 2.23 0.56 2.70 2.18 0.61 2.58 2.12 0.66 2.53 2.10 0.68 2.46 2.07 0.72 2.33 2.02 0.77
18.0 25.0 2.95 2.37 0.56 2.83 2.32 0.61 2.70 2.27 0.67 2.65 2.25 0.69 2.58 2.22 0.72 2.46 2.18 0.77
19.4 26.7 3.01 2.54 0.56 2.89 2.49 0.61 2.76 2.44 0.67 2.71 2.42 0.69 2.64 2.39 0.72 2.52 2.35 0.77
22.0 30.0 3.19 2.46 0.57 3.07 2.42 0.62 2.95 2.37 0.67 2.90 2.36 0.69 2.82 2.33 0.73 2.70 2.29 0.78
24.0 32.0 3.31 2.41 0.57 3.19 2.37 0.62 3.07 2.33 0.68 3.02 2.31 0.70 2.94 2.29 0.73 2.82 2.25 0.78
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (FDB)
EWB EDB 68 77 86 90 95 104
F F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 9.23 7.73 0.55 8.81 7.54 0.61 8.39 7.34 0.66 8.22 7.27 0.68 7.97 7.15 0.71 7.55 6.96 0.77
60.8 71.6 9.64 7.61 0.56 9.22 7.42 0.61 8.80 7.24 0.66 8.64 7.17 0.68 8.39 7.06 0.72 7.97 6.89 0.77
64.4 77.0 10.06 8.09 0.56 9.64 7.92 0.61 9.22 7.76 0.67 9.05 7.69 0.69 8.80 7.59 0.72 8.38 7.43 0.77
67.0 80.0 10.27 8.65 0.56 9.85 8.49 0.61 9.43 8.33 0.67 9.26 8.26 0.69 9.00 8.17 0.72 8.59 8.01 0.77
71.6 86.0 10.89 8.39 0.57 10.47 8.24 0.62 10.05 8.10 0.67 9.88 8.05 0.69 9.63 7.96 0.73 9.21 7.82 0.78
75.2 89.6 11.30 8.21 0.57 10.88 8.08 0.62 10.46 7.95 0.68 10.30 7.90 0.70 10.05 7.82 0.73 9.63 7.69 0.78
Heating
AFR 11.4
Temp: Celsius
TC, PI: kW
INDOOR OUTDOOR TEMPERATURE (CWB)
EDB 15 10 5 0 6 10
C TC PI TC PI TC PI TC PI TC PI TC PI
15.0 1.40 0.46 1.68 0.49 1.96 0.51 2.63 0.67 3.03 0.71 3.30 0.73
21.1 1.31 0.48 1.59 0.50 1.87 0.53 2.53 0.69 2.93 0.72 3.19 0.75
22.0 1.27 0.48 1.56 0.51 1.84 0.53 2.49 0.69 2.89 0.73 3.15 0.75
24.0 1.24 0.49 1.52 0.51 1.80 0.54 2.45 0.70 2.85 0.74 3.11 0.76
25.0 1.22 0.49 1.50 0.51 1.79 0.54 2.43 0.70 2.83 0.74 3.09 0.76
27.0 1.19 0.50 1.47 0.52 1.75 0.54 2.39 0.71 2.79 0.74 3.05 0.77
Temp: Fahrenheit
TC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (FWB)
EDB 5 14 23 32 43 50
F TC PI TC PI TC PI TC PI TC PI TC PI
59.0 4.76 0.46 5.72 0.49 6.68 0.51 8.99 0.67 10.34 0.71 11.25 0.73
70.0 4.47 0.48 5.43 0.50 6.39 0.53 8.64 0.69 10.00 0.72 10.90 0.75
71.6 4.35 0.48 5.31 0.51 6.27 0.53 8.50 0.69 9.86 0.73 10.76 0.75
75.2 4.23 0.49 5.19 0.51 6.15 0.54 8.37 0.70 9.72 0.74 10.62 0.76
77.0 4.17 0.49 5.13 0.51 6.09 0.54 8.30 0.70 9.65 0.74 10.56 0.76
80.6 4.06 0.50 5.02 0.52 5.98 0.54 8.16 0.71 9.51 0.74 10.42 0.77
60 Hz, 230 V
Cooling
AFR 11.8
BF 0.22
Temp: Celsius
TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (CDB)
EWB EDB 20 25 30 32 35 40
C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20.0 2.70 2.27 0.55 2.58 2.21 0.61 2.46 2.15 0.66 2.41 2.13 0.68 2.34 2.10 0.71 2.21 2.04 0.77
16.0 22.0 2.83 2.23 0.56 2.70 2.18 0.61 2.58 2.12 0.66 2.53 2.10 0.68 2.46 2.07 0.72 2.33 2.02 0.77
18.0 25.0 2.95 2.37 0.56 2.83 2.32 0.61 2.70 2.27 0.67 2.65 2.25 0.69 2.58 2.22 0.72 2.46 2.18 0.77
19.4 26.7 3.01 2.54 0.56 2.89 2.49 0.61 2.76 2.44 0.67 2.71 2.42 0.69 2.64 2.39 0.72 2.52 2.35 0.77
22.0 30.0 3.19 2.46 0.57 3.07 2.42 0.62 2.95 2.37 0.67 2.90 2.36 0.69 2.82 2.33 0.73 2.70 2.29 0.78
24.0 32.0 3.31 2.41 0.57 3.19 2.37 0.62 3.07 2.33 0.68 3.02 2.31 0.70 2.94 2.29 0.73 2.82 2.25 0.78
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (FDB)
EWB EDB 68 77 86 90 95 104
F F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 9.23 7.73 0.55 8.81 7.54 0.61 8.39 7.34 0.66 8.22 7.27 0.68 7.97 7.15 0.71 7.55 6.96 0.77
60.8 71.6 9.64 7.61 0.56 9.22 7.42 0.61 8.80 7.24 0.66 8.64 7.17 0.68 8.39 7.06 0.72 7.97 6.89 0.77
64.4 77.0 10.06 8.09 0.56 9.64 7.92 0.61 9.22 7.76 0.67 9.05 7.69 0.69 8.80 7.59 0.72 8.38 7.43 0.77
67.0 80.0 10.27 8.65 0.56 9.85 8.49 0.61 9.43 8.33 0.67 9.26 8.26 0.69 9.00 8.17 0.72 8.59 8.01 0.77
71.6 86.0 10.89 8.39 0.57 10.47 8.24 0.62 10.05 8.10 0.67 9.88 8.05 0.69 9.63 7.96 0.73 9.21 7.82 0.78
75.2 89.6 11.30 8.21 0.57 10.88 8.08 0.62 10.46 7.95 0.68 10.30 7.90 0.70 10.05 7.82 0.73 9.63 7.69 0.78
Heating
AFR 11.4
Temp: Celsius
TC, PI: kW
INDOOR OUTDOOR TEMPERATURE (CWB)
EDB 15 10 5 0 6 10
C TC PI TC PI TC PI TC PI TC PI TC PI
15.0 1.40 0.46 1.68 0.49 1.96 0.51 2.63 0.67 3.03 0.71 3.30 0.73
21.1 1.31 0.48 1.59 0.50 1.87 0.53 2.53 0.69 2.93 0.72 3.19 0.75
22.0 1.27 0.48 1.56 0.51 1.84 0.53 2.49 0.69 2.89 0.73 3.15 0.75
24.0 1.24 0.49 1.52 0.51 1.80 0.54 2.45 0.70 2.85 0.74 3.11 0.76
25.0 1.22 0.49 1.50 0.51 1.79 0.54 2.43 0.70 2.83 0.74 3.09 0.76
27.0 1.19 0.50 1.47 0.52 1.75 0.54 2.39 0.71 2.79 0.74 3.05 0.77
Temp: Fahrenheit
TC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (FWB)
EDB 5 14 23 32 43 50
F TC PI TC PI TC PI TC PI TC PI TC PI
59.0 4.76 0.46 5.72 0.49 6.68 0.51 8.99 0.67 10.34 0.71 11.25 0.73
70.0 4.47 0.48 5.43 0.50 6.39 0.53 8.64 0.69 10.00 0.72 10.90 0.75
71.6 4.35 0.48 5.31 0.51 6.27 0.53 8.50 0.69 9.86 0.73 10.76 0.75
75.2 4.23 0.49 5.19 0.51 6.15 0.54 8.37 0.70 9.72 0.74 10.62 0.76
77.0 4.17 0.49 5.13 0.51 6.09 0.54 8.30 0.70 9.65 0.74 10.56 0.76
80.6 4.06 0.50 5.02 0.52 5.98 0.54 8.16 0.71 9.51 0.74 10.42 0.77
Symbols: Notes:
AFR : Airflow rate (m /min.)
3
1. shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in the
BF : Bypass factor above tables. (Figures out of the tables should not be used for calculation.)
EWB : Entering wet bulb temp. (C) / (F) 3. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 25 ft (7.5 m)
EDB : Entering dry bulb temp. (C) / (F) Level difference : 0 ft (0 m)
TC : Total capacity (kW) / (kBtu/h) 4. Cooling capacity at 15CDB and 5FDB.
SHC : Sensible heat capacity (kW) / (kBtu/h) Temp: Celsius
PI : Power input (kW) TC, SHC, PI: kW
60 Hz, 208 - 230 V
INDOOR OUTDOOR
EWB EDB 15 (CDB)
C C TC SHC PI
14.0 20.0 2.90 2.18 0.37
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
60 Hz, 208 - 230 V
INDOOR OUTDOOR
EWB EDB 5 (FDB)
F F TC SHC PI
57.2 68.0 9.90 7.45 0.37
3D093235
FTX12NMVJU + RX12NMVJU
60 Hz, 208 V
Cooling
AFR 12.3
BF 0.16
Temp: Celsius
TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (CDB)
EWB EDB 20 25 30 32 35 40
C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20.0 3.28 2.66 0.67 3.13 2.59 0.74 2.98 2.52 0.80 2.92 2.49 0.83 2.83 2.45 0.86 2.68 2.38 0.93
16.0 22.0 3.43 2.61 0.67 3.28 2.55 0.74 3.13 2.48 0.80 3.07 2.46 0.83 2.98 2.42 0.87 2.83 2.35 0.93
18.0 25.0 3.57 2.77 0.68 3.42 2.71 0.74 3.28 2.65 0.81 3.22 2.63 0.83 3.13 2.59 0.87 2.98 2.53 0.94
19.4 26.7 3.65 2.95 0.68 3.50 2.89 0.74 3.35 2.84 0.81 3.29 2.81 0.84 3.20 2.78 0.87 3.05 2.72 0.94
22.0 30.0 3.87 2.86 0.69 3.72 2.81 0.75 3.57 2.76 0.82 3.51 2.74 0.84 3.42 2.70 0.88 3.27 2.65 0.94
24.0 32.0 4.02 2.79 0.69 3.87 2.75 0.75 3.72 2.70 0.82 3.66 2.68 0.84 3.57 2.65 0.88 3.42 2.61 0.95
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (FDB)
EWB EDB 68 77 86 90 95 104
F F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 11.19 9.07 0.67 10.68 8.83 0.74 10.17 8.59 0.80 9.97 8.50 0.83 9.66 8.36 0.86 9.15 8.12 0.93
60.8 71.6 11.69 8.92 0.67 11.18 8.69 0.74 10.67 8.47 0.80 10.47 8.38 0.83 10.16 8.25 0.87 9.66 8.03 0.93
64.4 77.0 12.19 9.46 0.68 11.68 9.25 0.74 11.18 9.04 0.81 10.97 8.96 0.83 10.67 8.83 0.87 10.16 8.63 0.94
67.0 80.0 12.44 10.07 0.68 11.94 9.87 0.74 11.43 9.67 0.81 11.22 9.59 0.84 10.90 9.48 0.87 10.41 9.28 0.94
71.6 86.0 13.20 9.75 0.69 12.69 9.58 0.75 12.18 9.40 0.82 11.98 9.33 0.84 11.67 9.23 0.88 11.16 9.06 0.94
75.2 89.6 13.70 9.53 0.69 13.19 9.37 0.75 12.68 9.21 0.82 12.48 9.15 0.84 12.18 9.05 0.88 11.67 8.90 0.95
Heating
AFR 11.7
Temp: Celsius
TC, PI: kW
INDOOR OUTDOOR TEMPERATURE (CWB)
EDB 15 10 5 0 6 10
C TC PI TC PI TC PI TC PI TC PI TC PI
15.0 1.89 0.67 2.27 0.70 2.65 0.74 3.56 0.97 4.10 1.02 4.45 1.05
21.1 1.77 0.69 2.15 0.72 2.53 0.76 3.42 0.99 3.96 1.04 4.32 1.08
22.0 1.72 0.70 2.10 0.73 2.48 0.76 3.37 1.00 3.91 1.05 4.26 1.08
24.0 1.68 0.70 2.06 0.74 2.44 0.77 3.31 1.01 3.85 1.06 4.21 1.09
25.0 1.65 0.71 2.03 0.74 2.41 0.78 3.29 1.01 3.82 1.06 4.18 1.10
27.0 1.61 0.72 1.99 0.75 2.37 0.78 3.23 1.02 3.77 1.07 4.13 1.11
Temp: Fahrenheit
TC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (FWB)
EDB 5 14 23 32 43 50
F TC PI TC PI TC PI TC PI TC PI TC PI
59.0 6.43 0.67 7.73 0.70 9.03 0.74 12.15 0.97 13.98 1.02 15.20 1.05
70.0 6.04 0.69 7.33 0.72 8.63 0.76 11.68 0.99 13.50 1.04 14.73 1.08
71.6 5.88 0.70 7.18 0.73 8.47 0.76 11.49 1.00 13.32 1.05 14.55 1.08
75.2 5.72 0.70 7.02 0.74 8.31 0.77 11.31 1.01 13.14 1.06 14.36 1.09
77.0 5.64 0.71 6.94 0.74 8.24 0.78 11.21 1.01 13.05 1.06 14.27 1.10
80.6 5.48 0.72 6.78 0.75 8.08 0.78 11.03 1.02 12.86 1.07 14.08 1.11
60 Hz, 230 V
Cooling
AFR 12.3
BF 0.16
Temp: Celsius
TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (CDB)
EWB EDB 20 25 30 32 35 40
C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20.0 3.28 2.66 0.67 3.13 2.59 0.74 2.98 2.52 0.80 2.92 2.49 0.83 2.83 2.45 0.86 2.68 2.38 0.93
16.0 22.0 3.43 2.61 0.67 3.28 2.55 0.74 3.13 2.48 0.80 3.07 2.46 0.83 2.98 2.42 0.87 2.83 2.35 0.93
18.0 25.0 3.57 2.77 0.68 3.42 2.71 0.74 3.28 2.65 0.81 3.22 2.63 0.83 3.13 2.59 0.87 2.98 2.53 0.94
19.4 26.7 3.65 2.95 0.68 3.50 2.89 0.74 3.35 2.84 0.81 3.29 2.81 0.84 3.20 2.78 0.87 3.05 2.72 0.94
22.0 30.0 3.87 2.86 0.69 3.72 2.81 0.75 3.57 2.76 0.82 3.51 2.74 0.84 3.42 2.70 0.88 3.27 2.65 0.94
24.0 32.0 4.02 2.79 0.69 3.87 2.75 0.75 3.72 2.70 0.82 3.66 2.68 0.84 3.57 2.65 0.88 3.42 2.61 0.95
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (FDB)
EWB EDB 68 77 86 90 95 104
F F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 11.19 9.07 0.67 10.68 8.83 0.74 10.17 8.59 0.80 9.97 8.50 0.83 9.66 8.36 0.86 9.15 8.12 0.93
60.8 71.6 11.69 8.92 0.67 11.18 8.69 0.74 10.67 8.47 0.80 10.47 8.38 0.83 10.16 8.25 0.87 9.66 8.03 0.93
64.4 77.0 12.19 9.46 0.68 11.68 9.25 0.74 11.18 9.04 0.81 10.97 8.96 0.83 10.67 8.83 0.87 10.16 8.63 0.94
67.0 80.0 12.44 10.07 0.68 11.94 9.87 0.74 11.43 9.67 0.81 11.22 9.59 0.84 10.90 9.48 0.87 10.41 9.28 0.94
71.6 86.0 13.20 9.75 0.69 12.69 9.58 0.75 12.18 9.40 0.82 11.98 9.33 0.84 11.67 9.23 0.88 11.16 9.06 0.94
75.2 89.6 13.70 9.53 0.69 13.19 9.37 0.75 12.68 9.21 0.82 12.48 9.15 0.84 12.18 9.05 0.88 11.67 8.90 0.95
Heating
AFR 11.7
Temp: Celsius
TC, PI: kW
INDOOR OUTDOOR TEMPERATURE (CWB)
EDB 15 10 5 0 6 10
C TC PI TC PI TC PI TC PI TC PI TC PI
15.0 1.89 0.67 2.27 0.70 2.65 0.74 3.56 0.97 4.10 1.02 4.45 1.05
21.1 1.77 0.69 2.15 0.72 2.53 0.76 3.42 0.99 3.96 1.04 4.32 1.08
22.0 1.72 0.70 2.10 0.73 2.48 0.76 3.37 1.00 3.91 1.05 4.26 1.08
24.0 1.68 0.70 2.06 0.74 2.44 0.77 3.31 1.01 3.85 1.06 4.21 1.09
25.0 1.65 0.71 2.03 0.74 2.41 0.78 3.29 1.01 3.82 1.06 4.18 1.10
27.0 1.61 0.72 1.99 0.75 2.37 0.78 3.23 1.02 3.77 1.07 4.13 1.11
Temp: Fahrenheit
TC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (FWB)
EDB 5 14 23 32 43 50
F TC PI TC PI TC PI TC PI TC PI TC PI
59.0 6.43 0.67 7.73 0.70 9.03 0.74 12.15 0.97 13.98 1.02 15.20 1.05
70.0 6.04 0.69 7.33 0.72 8.63 0.76 11.68 0.99 13.50 1.04 14.73 1.08
71.6 5.88 0.70 7.18 0.73 8.47 0.76 11.49 1.00 13.32 1.05 14.55 1.08
75.2 5.72 0.70 7.02 0.74 8.31 0.77 11.31 1.01 13.14 1.06 14.36 1.09
77.0 5.64 0.71 6.94 0.74 8.24 0.78 11.21 1.01 13.05 1.06 14.27 1.10
80.6 5.48 0.72 6.78 0.75 8.08 0.78 11.03 1.02 12.86 1.07 14.08 1.11
Symbols: Notes:
AFR : Airflow rate (m /min.)
3
1. shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in the
BF : Bypass factor above tables. (Figures out of the tables should not be used for calculation.)
EWB : Entering wet bulb temp. (C) / (F) 3. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 25 ft (7.5 m)
EDB : Entering dry bulb temp. (C) / (F) Level difference : 0 ft (0 m)
TC : Total capacity (kW) / (kBtu/h) 4. Cooling capacity at 15CDB and 5FDB.
SHC : Sensible heat capacity (kW) / (kBtu/h) Temp: Celsius
PI : Power input (kW) TC, SHC, PI: kW
60 Hz, 208 - 230 V
INDOOR OUTDOOR
EWB EDB 15 (CDB)
C C TC SHC PI
14.0 20.0 3.42 2.53 0.52
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
60 Hz, 208 - 230 V
INDOOR OUTDOOR
EWB EDB 5 (FDB)
F F TC SHC PI
57.2 68.0 11.66 8.61 0.52
3D093236
FTX18NMVJU + RX18NMVJU
60 Hz, 208 V
Cooling
AFR 20.2
BF 0.27
Temp: Celsius
TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (CDB)
EWB EDB 20 25 30 32 35 40
C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20.0 5.41 4.15 1.11 5.16 4.03 1.21 4.92 3.91 1.32 4.82 3.86 1.36 4.67 3.79 1.43 4.43 3.67 1.53
16.0 22.0 5.65 4.08 1.11 5.41 3.96 1.22 5.16 3.85 1.32 5.06 3.81 1.37 4.92 3.74 1.43 4.67 3.63 1.54
18.0 25.0 5.90 4.29 1.12 5.65 4.19 1.22 5.40 4.08 1.33 5.31 4.04 1.37 5.16 3.98 1.44 4.91 3.88 1.54
19.4 26.7 6.02 4.54 1.12 5.77 4.44 1.23 5.53 4.34 1.33 5.43 4.30 1.38 5.28 4.24 1.44 5.03 4.15 1.55
22.0 30.0 6.38 4.39 1.13 6.14 4.30 1.24 5.89 4.21 1.34 5.79 4.18 1.39 5.64 4.12 1.45 5.40 4.04 1.56
24.0 32.0 6.63 4.28 1.14 6.38 4.20 1.24 6.13 4.12 1.35 6.04 4.09 1.39 5.89 4.04 1.46 5.64 3.96 1.56
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (FDB)
EWB EDB 68 77 86 90 95 104
F F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 18.46 14.15 1.11 17.62 13.74 1.21 16.78 13.34 1.32 16.44 13.17 1.36 15.94 12.93 1.43 15.10 12.54 1.53
60.8 71.6 19.29 13.91 1.11 18.45 13.52 1.22 17.61 13.14 1.32 17.27 12.99 1.37 16.77 12.77 1.43 15.93 12.40 1.54
64.4 77.0 20.12 14.64 1.12 19.28 14.28 1.22 18.44 13.93 1.33 18.10 13.79 1.37 17.60 13.58 1.44 16.76 13.23 1.54
67.0 80.0 20.53 15.50 1.12 19.69 15.16 1.23 18.85 14.82 1.33 18.52 14.68 1.38 18.00 14.48 1.44 17.18 14.15 1.55
71.6 86.0 21.78 14.97 1.13 20.94 14.67 1.24 20.10 14.37 1.34 19.76 14.25 1.39 19.26 14.07 1.45 18.42 13.78 1.56
75.2 89.6 22.61 14.60 1.14 21.77 14.32 1.24 20.93 14.05 1.35 20.59 13.94 1.39 20.09 13.78 1.46 19.25 13.51 1.56
Heating
AFR 21.1
Temp: Celsius
TC, PI: kW
INDOOR OUTDOOR TEMPERATURE (CWB)
EDB 15 10 5 0 6 10
C TC PI TC PI TC PI TC PI TC PI TC PI
15.0 3.01 1.13 3.62 1.19 4.23 1.25 5.69 1.63 6.55 1.72 7.12 1.78
21.1 2.83 1.16 3.44 1.22 4.04 1.28 5.47 1.67 6.33 1.76 6.90 1.82
22.0 2.75 1.18 3.36 1.23 3.97 1.29 5.38 1.69 6.24 1.77 6.81 1.83
24.0 2.68 1.19 3.29 1.25 3.90 1.30 5.30 1.70 6.16 1.79 6.73 1.85
25.0 2.64 1.19 3.25 1.25 3.86 1.31 5.25 1.71 6.11 1.80 6.68 1.86
27.0 2.57 1.21 3.18 1.27 3.78 1.32 5.17 1.73 6.02 1.81 6.60 1.87
Temp: Fahrenheit
TC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (FWB)
EDB 5 14 23 32 43 50
F TC PI TC PI TC PI TC PI TC PI TC PI
59.0 10.29 1.13 12.36 1.19 14.43 1.25 19.42 1.63 22.34 1.72 24.29 1.78
70.0 9.65 1.16 11.72 1.22 13.80 1.28 18.67 1.67 21.60 1.76 23.55 1.82
71.6 9.40 1.18 11.47 1.23 13.54 1.29 18.37 1.69 21.30 1.77 23.25 1.83
75.2 9.14 1.19 11.22 1.25 13.29 1.30 18.07 1.70 21.00 1.79 22.95 1.85
77.0 9.02 1.19 11.09 1.25 13.16 1.31 17.93 1.71 20.85 1.80 22.80 1.86
80.6 8.76 1.21 10.84 1.27 12.91 1.32 17.63 1.73 20.55 1.81 22.51 1.87
60 Hz, 230 V
Cooling
AFR 20.2
BF 0.27
Temp: Celsius
TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (CDB)
EWB EDB 20 25 30 32 35 40
C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20.0 5.41 4.15 1.11 5.16 4.03 1.21 4.92 3.91 1.32 4.82 3.86 1.36 4.67 3.79 1.43 4.43 3.67 1.53
16.0 22.0 5.65 4.08 1.11 5.41 3.96 1.22 5.16 3.85 1.32 5.06 3.81 1.37 4.92 3.74 1.43 4.67 3.63 1.54
18.0 25.0 5.90 4.29 1.12 5.65 4.19 1.22 5.40 4.08 1.33 5.31 4.04 1.37 5.16 3.98 1.44 4.91 3.88 1.54
19.4 26.7 6.02 4.54 1.12 5.77 4.44 1.23 5.53 4.34 1.33 5.43 4.30 1.38 5.28 4.24 1.44 5.03 4.15 1.55
22.0 30.0 6.38 4.39 1.13 6.14 4.30 1.24 5.89 4.21 1.34 5.79 4.18 1.39 5.64 4.12 1.45 5.40 4.04 1.56
24.0 32.0 6.63 4.28 1.14 6.38 4.20 1.24 6.13 4.12 1.35 6.04 4.09 1.39 5.89 4.04 1.46 5.64 3.96 1.56
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (FDB)
EWB EDB 68 77 86 90 95 104
F F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 18.46 14.15 1.11 17.62 13.74 1.21 16.78 13.34 1.32 16.44 13.17 1.36 15.94 12.93 1.43 15.10 12.54 1.53
60.8 71.6 19.29 13.91 1.11 18.45 13.52 1.22 17.61 13.14 1.32 17.27 12.99 1.37 16.77 12.77 1.43 15.93 12.40 1.54
64.4 77.0 20.12 14.64 1.12 19.28 14.28 1.22 18.44 13.93 1.33 18.10 13.79 1.37 17.60 13.58 1.44 16.76 13.23 1.54
67.0 80.0 20.53 15.50 1.12 19.69 15.16 1.23 18.85 14.82 1.33 18.52 14.68 1.38 18.00 14.48 1.44 17.18 14.15 1.55
71.6 86.0 21.78 14.97 1.13 20.94 14.67 1.24 20.10 14.37 1.34 19.76 14.25 1.39 19.26 14.07 1.45 18.42 13.78 1.56
75.2 89.6 22.61 14.60 1.14 21.77 14.32 1.24 20.93 14.05 1.35 20.59 13.94 1.39 20.09 13.78 1.46 19.25 13.51 1.56
Heating
AFR 21.1
Temp: Celsius
TC, PI: kW
INDOOR OUTDOOR TEMPERATURE (CWB)
EDB 15 10 5 0 6 10
C TC PI TC PI TC PI TC PI TC PI TC PI
15.0 3.01 1.13 3.62 1.19 4.23 1.25 5.69 1.63 6.55 1.72 7.12 1.78
21.1 2.83 1.16 3.44 1.22 4.04 1.28 5.47 1.67 6.33 1.76 6.90 1.82
22.0 2.75 1.18 3.36 1.23 3.97 1.29 5.38 1.69 6.24 1.77 6.81 1.83
24.0 2.68 1.19 3.29 1.25 3.90 1.30 5.30 1.70 6.16 1.79 6.73 1.85
25.0 2.64 1.19 3.25 1.25 3.86 1.31 5.25 1.71 6.11 1.80 6.68 1.86
27.0 2.57 1.21 3.18 1.27 3.78 1.32 5.17 1.73 6.02 1.81 6.60 1.87
Temp: Fahrenheit
TC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (FWB)
EDB 5 14 23 32 43 50
F TC PI TC PI TC PI TC PI TC PI TC PI
59.0 10.29 1.13 12.36 1.19 14.43 1.25 19.42 1.63 22.34 1.72 24.29 1.78
70.0 9.65 1.16 11.72 1.22 13.80 1.28 18.67 1.67 21.60 1.76 23.55 1.82
71.6 9.40 1.18 11.47 1.23 13.54 1.29 18.37 1.69 21.30 1.77 23.25 1.83
75.2 9.14 1.19 11.22 1.25 13.29 1.30 18.07 1.70 21.00 1.79 22.95 1.85
77.0 9.02 1.19 11.09 1.25 13.16 1.31 17.93 1.71 20.85 1.80 22.80 1.86
80.6 8.76 1.21 10.84 1.27 12.91 1.32 17.63 1.73 20.55 1.81 22.51 1.87
Symbols: Notes:
AFR : Airflow rate (m /min.)
3
1. shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in the
BF : Bypass factor above tables. (Figures out of the tables should not be used for calculation.)
EWB : Entering wet bulb temp. (C) / (F) 3. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 25 ft (7.5 m)
EDB : Entering dry bulb temp. (C) / (F) Level difference : 0 ft (0 m)
TC : Total capacity (kW) / (kBtu/h) 4. Cooling capacity at 15CDB and 5FDB.
SHC : Sensible heat capacity (kW) / (kBtu/h) Temp: Celsius
PI : Power input (kW) TC, SHC, PI: kW
60 Hz, 208 - 230 V
INDOOR OUTDOOR
EWB EDB 15 (CDB)
C C TC SHC PI
14.0 20.0 5.44 4.02 0.71
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
60 Hz, 208 - 230 V
INDOOR OUTDOOR
EWB EDB 5 (FDB)
F F TC SHC PI
57.2 68.0 18.54 13.69 0.71
3D093237
FTX24NMVJU + RX24NMVJU
60 Hz, 208 V
Cooling
AFR 20.2
BF 0.27
Temp: Celsius
TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (CDB)
EWB EDB 20 25 30 32 35 40
C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20.0 6.05 4.47 1.29 6.05 4.47 1.43 5.77 4.33 1.55 5.66 4.27 1.60 5.49 4.19 1.68 5.20 4.04 1.71
16.0 22.0 6.64 4.54 1.31 6.35 4.40 1.43 6.06 4.27 1.56 5.94 4.21 1.61 5.77 4.13 1.68 5.48 4.00 1.72
18.0 25.0 6.92 4.74 1.32 6.63 4.61 1.44 6.35 4.49 1.57 6.23 4.43 1.62 6.06 4.36 1.69 5.77 4.24 1.73
19.4 26.7 7.07 4.99 1.32 6.78 4.86 1.45 6.49 4.74 1.57 6.37 4.69 1.62 6.20 4.62 1.70 5.91 4.50 1.73
22.0 30.0 7.49 4.80 1.33 7.21 4.69 1.46 6.92 4.59 1.58 6.80 4.54 1.63 6.63 4.48 1.71 6.34 4.37 1.74
24.0 32.0 7.78 4.67 1.34 7.49 4.57 1.46 7.20 4.47 1.59 7.09 4.43 1.64 6.91 4.38 1.71 6.63 4.28 1.75
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (FDB)
EWB EDB 68 77 86 90 95 104
F F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 20.65 15.25 1.29 20.65 15.25 1.43 19.70 14.77 1.55 19.31 14.57 1.60 18.72 14.28 1.68 17.73 13.80 1.71
60.8 71.6 22.65 15.49 1.31 21.66 15.02 1.43 20.68 14.55 1.56 20.28 14.37 1.61 19.69 14.09 1.68 18.71 13.64 1.72
64.4 77.0 23.62 16.18 1.32 22.64 15.74 1.44 21.65 15.30 1.57 21.26 15.13 1.62 20.67 14.87 1.69 19.68 14.45 1.73
67.0 80.0 24.11 17.01 1.32 23.12 16.59 1.45 22.14 16.17 1.57 21.75 16.01 1.62 21.20 15.76 1.70 20.17 15.35 1.73
71.6 86.0 25.57 16.39 1.33 24.59 16.01 1.46 23.60 15.64 1.58 23.21 15.50 1.63 22.62 15.28 1.71 21.63 14.92 1.74
75.2 89.6 26.55 15.94 1.34 25.56 15.60 1.46 24.58 15.26 1.59 24.18 15.13 1.64 23.59 14.93 1.71 22.61 14.60 1.75
Heating
AFR 21.1
Temp: Celsius
TC, PI: kW
INDOOR OUTDOOR TEMPERATURE (CWB)
EDB 15 10 5 0 6 10
C TC PI TC PI TC PI TC PI TC PI TC PI
15.0 3.35 1.29 4.02 1.36 4.70 1.43 6.32 1.87 7.27 1.96 7.91 2.03
21.1 3.14 1.33 3.82 1.40 4.49 1.46 6.08 1.91 7.03 2.01 7.67 2.08
22.0 3.06 1.34 3.73 1.41 4.41 1.48 5.98 1.93 6.93 2.03 7.57 2.09
24.0 2.98 1.36 3.65 1.43 4.33 1.49 5.88 1.95 6.84 2.05 7.47 2.11
25.0 2.94 1.37 3.61 1.43 4.28 1.50 5.83 1.96 6.79 2.06 7.42 2.12
27.0 2.85 1.38 3.53 1.45 4.20 1.51 5.74 1.97 6.69 2.07 7.33 2.14
Temp: Fahrenheit
TC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (FWB)
EDB 5 14 23 32 43 50
F TC PI TC PI TC PI TC PI TC PI TC PI
59.0 11.42 1.29 13.73 1.36 16.03 1.43 21.56 1.87 24.81 1.96 26.98 2.03
70.0 10.72 1.33 13.02 1.40 15.32 1.46 20.74 1.91 24.00 2.01 26.15 2.08
71.6 10.44 1.34 12.74 1.41 15.04 1.48 20.40 1.93 23.66 2.03 25.82 2.09
75.2 10.16 1.36 12.46 1.43 14.76 1.49 20.07 1.95 23.32 2.05 25.49 2.11
77.0 10.02 1.37 12.32 1.43 14.62 1.50 19.91 1.96 23.16 2.06 25.33 2.12
80.6 9.73 1.38 12.04 1.45 14.34 1.51 19.58 1.97 22.83 2.07 24.99 2.14
60 Hz, 230 V
Cooling
AFR 20.2
BF 0.27
Temp: Celsius
TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (CDB)
EWB EDB 20 25 30 32 35 40
C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20.0 6.05 4.47 1.29 6.05 4.47 1.43 5.77 4.33 1.55 5.66 4.27 1.60 5.49 4.19 1.68 5.20 4.04 1.71
16.0 22.0 6.64 4.54 1.31 6.35 4.40 1.43 6.06 4.27 1.56 5.94 4.21 1.61 5.77 4.13 1.68 5.48 4.00 1.72
18.0 25.0 6.92 4.74 1.32 6.63 4.61 1.44 6.35 4.49 1.57 6.23 4.43 1.62 6.06 4.36 1.69 5.77 4.24 1.73
19.4 26.7 7.07 4.99 1.32 6.78 4.86 1.45 6.49 4.74 1.57 6.37 4.69 1.62 6.20 4.62 1.70 5.91 4.50 1.73
22.0 30.0 7.49 4.80 1.33 7.21 4.69 1.46 6.92 4.59 1.58 6.80 4.54 1.63 6.63 4.48 1.71 6.34 4.37 1.74
24.0 32.0 7.78 4.67 1.34 7.49 4.57 1.46 7.20 4.47 1.59 7.09 4.43 1.64 6.91 4.38 1.71 6.63 4.28 1.75
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (FDB)
EWB EDB 68 77 86 90 95 104
F F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 20.65 15.25 1.29 20.65 15.25 1.43 19.70 14.77 1.55 19.31 14.57 1.60 18.72 14.28 1.68 17.73 13.80 1.71
60.8 71.6 22.65 15.49 1.31 21.66 15.02 1.43 20.68 14.55 1.56 20.28 14.37 1.61 19.69 14.09 1.68 18.71 13.64 1.72
64.4 77.0 23.62 16.18 1.32 22.64 15.74 1.44 21.65 15.30 1.57 21.26 15.13 1.62 20.67 14.87 1.69 19.68 14.45 1.73
67.0 80.0 24.11 17.01 1.32 23.12 16.59 1.45 22.14 16.17 1.57 21.75 16.01 1.62 21.20 15.76 1.70 20.17 15.35 1.73
71.6 86.0 25.57 16.39 1.33 24.59 16.01 1.46 23.60 15.64 1.58 23.21 15.50 1.63 22.62 15.28 1.71 21.63 14.92 1.74
75.2 89.6 26.55 15.94 1.34 25.56 15.60 1.46 24.58 15.26 1.59 24.18 15.13 1.64 23.59 14.93 1.71 22.61 14.60 1.75
Heating
AFR 21.1
Temp: Celsius
TC, PI: kW
INDOOR OUTDOOR TEMPERATURE (CWB)
EDB 15 10 5 0 6 10
C TC PI TC PI TC PI TC PI TC PI TC PI
15.0 3.35 1.29 4.02 1.36 4.70 1.43 6.32 1.87 7.27 1.96 7.91 2.03
21.1 3.14 1.33 3.82 1.40 4.49 1.46 6.08 1.91 7.03 2.01 7.67 2.08
22.0 3.06 1.34 3.73 1.41 4.41 1.48 5.98 1.93 6.93 2.03 7.57 2.09
24.0 2.98 1.36 3.65 1.43 4.33 1.49 5.88 1.95 6.84 2.05 7.47 2.11
25.0 2.94 1.37 3.61 1.43 4.28 1.50 5.83 1.96 6.79 2.06 7.42 2.12
27.0 2.85 1.38 3.53 1.45 4.20 1.51 5.74 1.97 6.69 2.07 7.33 2.14
Temp: Fahrenheit
TC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (FWB)
EDB 5 14 23 32 43 50
F TC PI TC PI TC PI TC PI TC PI TC PI
59.0 11.42 1.29 13.73 1.36 16.03 1.43 21.56 1.87 24.81 1.96 26.98 2.03
70.0 10.72 1.33 13.02 1.40 15.32 1.46 20.74 1.91 24.00 2.01 26.15 2.08
71.6 10.44 1.34 12.74 1.41 15.04 1.48 20.40 1.93 23.66 2.03 25.82 2.09
75.2 10.16 1.36 12.46 1.43 14.76 1.49 20.07 1.95 23.32 2.05 25.49 2.11
77.0 10.02 1.37 12.32 1.43 14.62 1.50 19.91 1.96 23.16 2.06 25.33 2.12
80.6 9.73 1.38 12.04 1.45 14.34 1.51 19.58 1.97 22.83 2.07 24.99 2.14
Symbols: Notes:
AFR : Airflow rate (m /min.)
3
1. shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in the
BF : Bypass factor above tables. (Figures out of the tables should not be used for calculation.)
EWB : Entering wet bulb temp. (C) / (F) 3. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 25 ft (7.5 m)
EDB : Entering dry bulb temp. (C) / (F) Level difference : 0 ft (0 m)
TC : Total capacity (kW) / (kBtu/h) 4. Cooling capacity at 15CDB and 5FDB.
SHC : Sensible heat capacity (kW) / (kBtu/h) Temp: Celsius
PI : Power input (kW) TC, SHC, PI: kW
60 Hz, 208 - 230 V
INDOOR OUTDOOR
EWB EDB 15 (CDB)
C C TC SHC PI
14.0 20.0 5.95 4.39 0.56
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
60 Hz, 208 - 230 V
INDOOR OUTDOOR
EWB EDB 5 (FDB)
F F TC SHC PI
57.2 68.0 20.35 15.03 0.56
3D093238A
(%) (R-410A)
100
Capacity correction factor
90
Piping length
7.3.2 18 Class
(%) (R-410A)
100
Capacity correction factor
90
Piping length
7.3.3 24 Class
(%) (R-410A)
100
Piping length
Note: The graphs show the factor when additional refrigerant of the proper quantity is charged.
8. Operation Limit
RK09/12/18/24NMVJU
Cooling
122
114.8
104
Continuous operation
Pull-down period
86
50
32
14
RX09/12/18/24NMVJU
Cooling 70 Heating
122 64.4
114.8
60
104
Continuous operation
50
Pull-down period
86
Outdoor temp. (FWB)
Outdoor temp. (FDB)
Continuous operation
41
68
32
50
23
32
14
14
9. Sound Level
9.1 Measuring Location
3.3 ft 3.3 ft
(1 m) (1 m)
(0.8 m)
2.6 ft
MICROPHONE
MICROPHONE
dB (0dB=0.0002 bar)
NC-50 OPERATING CONDITIONS NC-50 OPERATING CONDITIONS
POWER SOURCE 208/230V 60Hz POWER SOURCE 208/230V 60Hz
40 JIS STANDARD 40 JIS STANDARD
NC-40 60Hz 208/230V (H) NC-40 60Hz 208/230V (H)
60Hz 208/230V (L) 60Hz 208/230V (L)
30 30
NC-30 Cooling NC-30 Cooling
20 20
APPROXIMATE APPROXIMATE
THRESHOLD HEARING NC-20 THRESHOLD HEARING
FOR CONTINUOUS FOR CONTINUOUS NC-20
NOISE NOISE
63 125 250 500 1000 2000 4000 8000 4D092958A 63 125 250 500 1000 2000 4000 8000 4D092887A
OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND CENTER FREQUENCY (Hz)
FTK18NMVJU FTK24NMVJU
COOLING COOLING
70 OVER ALL (dB) 70 OVER ALL (dB)
NC-70 NC-70
60Hz 60Hz 60Hz 60Hz
SCALE 208/230V 208/230V SCALE 208/230V 208/230V
OCTAVE BAND SOUND PRESSURE LEVEL
dB (0dB=0.0002 bar)
20 20
APPROXIMATE APPROXIMATE
THRESHOLD HEARING THRESHOLD HEARING NC-20
FOR CONTINUOUS NC-20 FOR CONTINUOUS
NOISE NOISE
63 125 250 500 1000 2000 4000 8000 4D093070 63 125 250 500 1000 2000 4000 8000 4D093071
OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND CENTER FREQUENCY (Hz)
COOLING HEATING
70 OVER ALL (dB) 70 OVER ALL (dB)
NC-70 NC-70
60Hz 60Hz 60Hz 60Hz
SCALE 208/230V 208/230V SCALE 208/230V 208/230V
(H) (L) (H) (L)
OCTAVE BAND SOUND PRESSURE LEVEL
dB (0dB=0.0002 bar)
NC-50 OPERATING CONDITIONS NC-50 OPERATING CONDITIONS
POWER SOURCE 208/230V 60Hz POWER SOURCE 208/230V 60Hz
40 JIS STANDARD 40 JIS STANDARD
NC-40 60Hz 208/230V (H) NC-40 60Hz 208/230V (H)
60Hz 208/230V (L) 60Hz 208/230V (L)
30 30
NC-30 Cooling NC-30 Heating
20 20
APPROXIMATE APPROXIMATE
THRESHOLD HEARING NC-20 THRESHOLD HEARING NC-20
FOR CONTINUOUS FOR CONTINUOUS
NOISE NOISE
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 3D092957A
OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND CENTER FREQUENCY (Hz)
FTX12NMVJU
COOLING HEATING
70 OVER ALL (dB) 70 OVER ALL (dB)
NC-70 NC-70
60Hz 60Hz 60Hz 60Hz
SCALE 208/230V 208/230V SCALE 208/230V 208/230V
(H) (L) (H) (L)
OCTAVE BAND SOUND PRESSURE LEVEL
dB (0dB=0.0002 bar)
20 20
APPROXIMATE APPROXIMATE
THRESHOLD HEARING NC-20 THRESHOLD HEARING NC-20
FOR CONTINUOUS FOR CONTINUOUS
NOISE NOISE
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 3D092886A
OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND CENTER FREQUENCY (Hz)
FTX18NMVJU
COOLING HEATING
70 70
NC-70 NC-70
60Hz 60Hz 60Hz 60Hz
SCALE 208/230V 208/230V SCALE 208/230V 208/230V
OCTAVE BAND SOUND PRESSURE LEVEL
60 60
NC-60 A 49 38 NC-60 A 49 37
dB (0dB=0.0002 bar)
20 20
APPROXIMATE APPROXIMATE
THRESHOLD HEARING THRESHOLD HEARING NC-20
FOR CONTINUOUS NC-20 FOR CONTINUOUS
NOISE NOISE
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 3D093064
OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND CENTER FREQUENCY (Hz)
FTX24NMVJU
COOLING HEATING
70 70
NC-70 NC-70
60Hz 60Hz 60Hz 60Hz
SCALE 208/230V 208/230V SCALE 208/230V 208/230V
OCTAVE BAND SOUND PRESSURE LEVEL
dB (0dB=0.0002 bar)
NC-50 OPERATING CONDITIONS NC-50 OPERATING CONDITIONS
POWER SOURCE 208/230V 60Hz POWER SOURCE 208/230V 60Hz
40 JIS STANDARD 40 JIS STANDARD
NC-40 60Hz 208/230V (H) NC-40 60Hz 208/230V (H)
60Hz 208/230V (L) 60Hz 208/230V (L)
30 30
Cooling NC-30 Heating
NC-30
20 20
APPROXIMATE APPROXIMATE
THRESHOLD HEARING THRESHOLD HEARING NC-20
FOR CONTINUOUS FOR CONTINUOUS
NOISE NC-20 NOISE
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 3D093065
OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND CENTER FREQUENCY (Hz)
COOLING COOLING
70 OVER ALL (dB) 70 OVER ALL (dB)
NC-70 NC-70
dB (0dB=0.0002 bar)
NC-50 OPERATING CONDITIONS NC-50 OPERATING CONDITIONS
POWER SOURCE 208-230V 60Hz POWER SOURCE 208-230V 60Hz
40 JIS STANDARD 40 JIS STANDARD
NC-40 NC-40
Cooling Cooling
30 30
NC-30 NC-30
20 20
APPROXIMATE APPROXIMATE
THRESHOLD HEARING THRESHOLD HEARING
FOR CONTINUOUS NC-20 FOR CONTINUOUS NC-20
NOISE NOISE
63 125 250 500 1000 2000 4000 8000 4D093179 63 125 250 500 1000 2000 4000 8000 4D093180
OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND CENTER FREQUENCY (Hz)
RK18NMVJU RK24NMVJU
COOLING COOLING
70 OVER ALL (dB) 70 OVER ALL (dB)
NC-70 NC-70
60 60
NC-60 A 54 NC-60 A 55
dB (0dB=0.0002 bar)
20 20
APPROXIMATE APPROXIMATE
THRESHOLD HEARING THRESHOLD HEARING
FOR CONTINUOUS NC-20 FOR CONTINUOUS NC-20
NOISE NOISE
63 125 250 500 1000 2000 4000 8000 4D093181 63 125 250 500 1000 2000 4000 8000 4D093182
OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND CENTER FREQUENCY (Hz)
COOLING HEATING
70 OVER ALL (dB) 70 OVER ALL (dB)
NC-70 NC-70
dB (0dB=0.0002 bar)
NC-50 OPERATING CONDITIONS NC-50 OPERATING CONDITIONS
POWER SOURCE 208-230V 60Hz POWER SOURCE 208-230V 60Hz
40 JIS STANDARD 40 JIS STANDARD
NC-40 NC-40
Cooling Heating
30 30
NC-30 NC-30
20 20
APPROXIMATE APPROXIMATE
THRESHOLD HEARING NC-20 THRESHOLD HEARING NC-20
FOR CONTINUOUS FOR CONTINUOUS
NOISE NOISE
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 3D093170
OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND CENTER FREQUENCY (Hz)
RX12NMVJU
COOLING HEATING
70 OVER ALL (dB) 70 OVER ALL (dB)
NC-70 NC-70
dB (0dB=0.0002 bar)
Cooling Heating
30 30
NC-30 NC-30
20 20
APPROXIMATE APPROXIMATE
THRESHOLD HEARING NC-20 THRESHOLD HEARING NC-20
FOR CONTINUOUS FOR CONTINUOUS
NOISE NOISE
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 3D093171
OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND CENTER FREQUENCY (Hz)
RX18NMVJU
COOLING HEATING
70 OVER ALL (dB) 70 OVER ALL (dB)
NC-70 NC-70
60 60
NC-60 A 54 NC-60 A 54
dB (0dB=0.0002 bar)
Cooling Heating
30 30
NC-30 NC-30
20 20
APPROXIMATE APPROXIMATE
THRESHOLD HEARING NC-20 THRESHOLD HEARING NC-20
FOR CONTINUOUS FOR CONTINUOUS
NOISE NOISE
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 3D093172
OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND CENTER FREQUENCY (Hz)
RX24NMVJU
COOLING HEATING
70 OVER ALL (dB) 70 OVER ALL (dB)
NC-70 NC-70
dB (0dB=0.0002 bar)
NC-50 OPERATING CONDITIONS NC-50 OPERATING CONDITIONS
POWER SOURCE 208-230V 60Hz POWER SOURCE 208-230V 60Hz
40 JIS STANDARD 40 JIS STANDARD
NC-40 NC-40
Cooling Heating
30 30
NC-30 NC-30
20 20
APPROXIMATE APPROXIMATE
THRESHOLD HEARING NC-20 THRESHOLD HEARING NC-20
FOR CONTINUOUS FOR CONTINUOUS
NOISE NOISE
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 3D093173
OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND CENTER FREQUENCY (Hz)
Symbols: Notes:
MCA : Min. circuit amps (A) 1. RHz is the max frequency that comes in cooling operation and
heating operation.
MFA : Max. fuse amps (A) 2. RLA is the max current that comes in cooling operation and heating
RHz : Rated operating frequency (Hz) operation.
3. Maximum allowable voltage variation between phases is 2%.
RLA : Rated load amps (A) 4. Select wire size based on the larger value of MCA.
OFM : Outdoor fan motor 5. Instead of a fuse, use a circuit breaker.
6. Be sure to install a ground leak detector.
IFM : Indoor fan motor (This unit uses an inverter, which means that a ground leak detector
W : Fan motor rated output (W) capable of handling high harmonics must be used in order to prevent
malfunctioning of the ground leak detector.)
FLA : Full load amps (A)
3D093165
3P379970-1
3P379970-2A
3P379751-2A
3P379751-1A
CAUTION
1. No switch box or staple is supplied. Prepare them locally.
2. No remote controller cord is supplied. Prepare the optional remote controller cord 4 wire.
3. Be sure to turn off the power to any apparatus connected prior to mounting.
4. Prior to mounting equipment, touch something metallic such as a doorknob to remove static
electricity from your body. Never touch the remote controller board or the adapter board.
5. Keep the wiring away from any other power source lines to avoid electric noise (external noise).
6. Select a flat surface, wherever possible, to mount the remote controller. To prevent deformation
of the cases, do not overtighten the mounting screws.
KJB2121A KJB1111A
Switch box
(Field supplied parts)
(Mounting with supplied wood screws) (Mounting with supplied double-face adhesive tape)
3. Wiring
Remote control adapter (attached)
Connector
Tie-band
(to secure the cord)
Attached
Using wire cutters, make
five-wire cord
a notch for wiring and
Remote controller cord then seal the notch to
(Note 1) ensure it is waterproof.
Lower case
Tie-band Note 1) Ground the both ends of the shielded wire.
(to secure the cord)
Remote controller cord 4 wire
Item No. Length
BRCW901A03 Approx. 3m (10ft)
Connector Connector
Remote controller
BRCW901A08 Approx. 8m (26ft)
Remote controller
board board Tie-band
Upper case (to secure the cord)
assembly To remote control adapter
(Cord drawn out on the back) (Cord drawn out on the top)
4. Placing the upper case assembly of the remote controller and the upper case of the remote controller adapter back into their original positions
3P202923-2B
Swing button
( page 9)
CAUTION
This remote controller cannot be used together with a standard wireless remote controller.
Otherwise, what appears on this remote controller's display may fail to correspond to actual
operating conditions.
1 Press .
3 Press .
blinks.
(This completes the current time setting)
The clock's accuracy is 30 seconds per month.
Notes
Please take note of the following points
To use the unit efficiently
Electric power is consumed even when the air
Avoid overcooling or overheating. conditioner is not in operation.
Moderate room temperature setting When the unit is not used for a long period of
contributes to power saving. time such as during off-season, turn off the
breaker.
Recommended
temperature setting Operating conditions
For cooling 26~28C (79F~82F) If the operation is continued under any
For heating 20~22C (68F~72F) conditions other than the following, the safety
device may work to stop the operation.
Hang a blind or a curtain on the window. Also, dew may form on the indoor unit and drip
This will enhance the cooling/heating effect from it. (Cooling/DRY)
by intercepting direct sunlight and drafts. Outdoor temp. -10 to 46C (14F to 115F)
Cooling Room temp. 18 to 32C (64F to 90F)
A clogged air filter reduces Indoor humidity Less than 80%
the cooling/heating effect and wastes Outdoor temp. -10 to 46C (14F to 115F)
energy. Clean the air filter monthly (every DRY Room temp. 18 to 32C (64F to 90F)
two weeks as required) or so. Indoor humidity Less than 80%
12
Notes
Temperature indication change between Celsius and Fahrenheit on the remote controller
Change the temperature indication in the modes other than the DRY mode.
In the DRY mode, temperature indication setting cannot be changed because the temperature is not indicated.
When the Fahrenheit temperature indication is changed to Celsius one, the temperature value
(0.5C) will be rounded up. Thus, the preset temperature may be changed.
Example:
A preset temperature of 65F (equivalent to 18.5C) will be changed to 19C (66F) b y changing the temperature indication.
In this case, if you change the Celsius temperature indication again to the Fahrenheit one, the preset temperature is shown not as 65F but
as 66F (equivalent to 19C). If the preset temperature is 66F (equivalent to 19C) and is changed to the Celsius temperature indication,
the indication becomes 19C (66F). In this case, no change by the temperature indication change is observed.
When the temperature indication change is set, the preset temperature is transmitted to the
indoor unit so that the reception sound will be heard from the indoor unit.
(Heating) (Cooling)
1
(DRY) (Cooling) Cooling only
model
2 Press .
The run indicator lamp lights up.
Operation
Setting mode Automatic Cooling Heating DRY
to be adjusted
Temperature is adjustable.
Recommended temperature Temperature
Cooling : 26C-28C (79F~82F)
cannot be
Heating : 20C-22C (68F~72F) adjusted.
(Temperature)
When the unit runs in the cooling or heating mode at a low airflow rate, the cooling or heating effect
may be insufficient.
Heating operation
Since the heating operation is performed by If the outdoor unit gets frosted during heating
taking the heat from outdoor into the room, operation, the heating capacity is decreased.
the heating capacity decreases as the outdoor In this case, the unit starts defrosting
temperature lowers. If the room is not heated operation.
sufficiently, it is recommended to use other No hot air comes out of the indoor unit during
heating appliance at the same time. defrosting operation.
Since the air conditioner heats the whole room
by circulating hot air, it takes some time to
heat the entire room completely.
Notes
In fixing the horizontal airflow direction, keep the horizontal airflow direction louvers tilted
downward in the heating mode, and keep them nearly horizontal level in the cooling or DRY mode.
This will enhance the cooling and heating effect.
On the air conditioners with vertical and horizontal swing function, be sure to adjust the airflow
directions using the remote controller. Do not forcibly adjust louvers by hand or a malfunction may
occur.
The vertical and horizontal louvers cannot move at the same time.
Note
The operating procedure and remote controller display are different depending on the
indoor unit being connected.
Read How to Adjust the Airflow Direction in the air conditioners Operation Manual.
10
Timer Operation
The Timer Operation feature automatically turns off operation when you go to sleep and turns it back
on when you wake up.
Use the DAILY Timer mode on weekdays, and the ONE TIME timer mode on weekends.
35
ONE TIME timer
1
DAILY timer
246
TIMER OFF
11
light up.
Notes
12
Timer Operation
To select the DAILY timer mode:
Timers 1 2
1 Press to select the DAILY timer mode. Two pairs of ON and OFF time
settings can be programmed.
Each time the button is pressed, the modes
change as follows.
TIMER OFF
at a glance.
OFF time 1 2
Note
13
DAILY timer
After programming, the system starts and stops each day at the preset times. Two pairs of time settings
can be programmed.
(Example: 8:00 ~ 10:00, and 18:00 ~ 23:00)
2 Make the ON and OFF time settings. Take the steps from to .
Program example: 8:00 ~ 10:00, and 18:00 ~ 23:00
Procedure
to make the
Press Press
timer setting.
Settings
ON time setting
When the timer 1 is not
used, save the setting
Timer
as
1
OFF time setting
ON time setting
When the timer 2 is not
Timer
2
OFF time setting
Note
This means that Timers and are This means that the timer has not been
programmed for the same time settings. programmed yet.
New time settings must be made.
14
Cleaning
Cleaning the remote controller
Wipe it clean with soft, dry cloth.
Do not use any water hotter than 40C (104F), or v olatile liquids such as benzine, gasoline and
thinner, polishing powder, or anything hard such as a scrub brush.
3
1 Press to select the cooling
mode.
3 Press .
The airflow rate remains the same, and is not
adjustable.
Run the system when the room temperature
2 1 is below 28C (82F).
15
3P202922-2B
3P169427-1
3P248024-2
3P248024-1D
3P248024-3D
1P398933-1
3P363899-2C
3P397163-1
3P398171-1
Specifications, designs and other content appearing in this brochure are current as of February 2015 but subject to change without notice.